Professional Documents
Culture Documents
CAT.NO.E11124-V1710
All new N-Instrumentation taking
energy efficiency to the next level
Since the introduction of the original walk-in chamber back in 1960, we’ve sold more than
10,000 units throughout the world. Throughout the history of the model, we’ve been
implementing the latest, the best available technology to improve its performance as well as
its efficiency.
The latest E Series walk-in type chamber is no exception. With epoch-making technologies
such as cross output control system (patented in Japan) and active map system, the E-Series is
now able to reduce its energy consumption up to 50% compared to its predecessor.
Now, the E Series capabilities are even further optimized with the N-instrumentation,
a highly-accurate controller with user-friendly human-machine interface, to support easy
operation and network solutions.
The E-Series, performance efficiency redefined.
1
* Equipped with options. 2
Series
100
95
EBE −40 to +80°C 10 to 95%rh
Temperature & Humidity Chambers
80
60
Humidity
(%rh)
EBL −30 to +80°C 10 to 95%rh 40
20
Frosting range
0 10 20 30 40 50 60 70 80 90
Temperature (°C)
EBR −10 to +80°C 20 to 95%rh
*Frost-free range is above +15°C TBL TBR Frost-free
during operation. TBE range
Unit: mm
2100
2100
2100
恒温恒湿室
60
湿度
70 0 70 70
19 197 19 19
1020 1970 (%rh) 3020 4070
TBL -30~+80℃ 10~95%rh 40
0 10 20 30 40 50 60 70 80 90
温度(℃)
TBR -10~+80℃ 20~95%rh
※温度運転時は+15℃以上が TBL フロストフリー
2100
2100
2100
2100
フロストフリー範囲となります。 TBR
TBE 範囲
12.3 m2 16.6 m2 20.8 m2 25.1 m2
20 70 70 70
30 40 40 40
4070 4070 5120 6170
TBF -40~+80℃
恒温室
TBU -30~+80℃
3 TBUU -10~+80℃
Characteristics
Security measures
Password authentication is required
Network
when accessing the USB flash drive.
LAN port and/or USB port function can
Ethernet PC
be terminated as required.
Interface
• Remote monitoring Walk-In Type Temperature
• Operation* (& Humidity) Chamber Tablet
(Test pattern change, run start/stop)
• Program pattern edit and copy*
• Data management
• Email alert • Multiple unit connection
*Option Ethernet
Hub
PC
Tablet
(with Wi-Fi function)
Wi-Fi
router
4
Characteristics
PC Mobile phone
Smartphone
5
Network
Characteristics
Backtrace function
インターネット
試験室
T h i s f u n c t io n i s a c t iv a t e d i n t h e A
稼動状況が確認できます。
Once we receive an email with this data
attached, we will analyze it and execute
Backtrace setting
troubleshooting to find ways to resolve the
situation.
(Sold separately)
Intranet
Network
camera
Measuring
Test chambers of instrument
other manufacturers
6
Characteristics
Trend-graph display
Both the set temperature (and humidity)
and the actual are stored in the memory
and can be displayed on the monitor as a
trend graph. The interval of measurements
can be set manually.
Trend-graph These data can be transferred to a USB
memory.
Information notification
The INFO icon will blink when chamber
information is requiring your attention.
Multi-lingual display
The controller supports:
Japanese
English
USB port Chinese (Traditional/Simplified)
Korean
Control area
Two modes for even more
energy savings
The new E Series is eco-friendly as is,
but we have an additional energy-saving
mode called “Eco-Mode,” to help you
further reduce your energy bill.
Eco-mode selection screen
7
Characteristics
35,000 500,000
operation. Approx. 60% (yen)
30,000
reduction
Yearly power fee
25,000
20,000 300,000
2
15,000
(¥
10,000
5,000 100,000
0
Previous series (EBL-4H) E Series (EBL-4E)
8
Characteristics
Reduced odors/siloxane
Newly developed sealant material that
reduced low-molecular siloxane is used in
the panel connections.
This sealant not only prevents any effect on
the specimen electrical contact failures caused
by siloxane in the chamber but also greatly
reduces ir ritating odors emitted by the
material, providing a comfortable environment
to the operator.
Cycle time defrost system ● Temperature & humidity control range with
The standard-equipped defrost system can frost-free expansion (option)
100
aut om at ic a l ly r e move f r o s t f r om t he 95 EBL
EBE
evaporator when operating in the frosting 80
range by simply setting the time via the EBR
10
Characteristics
We deliver custom-made
chambers
Viewing window Option: Large viewing window
(W180 mm x H289 mm ) (W440 mm x H295 mm) From minor modif ications to major
customizations, we can design a chamber
to accommodate your requirements.
Custom-made specifications
High temperature specification Highest adjustable temperature may be raised to +120°C by changing the insulation method.
Equipped with a cascade refrigeration system for lowest temperature measurements even below
Cryogenic specification
–40°C.
Low-temperature/low-humidity control range may be expanded by using dry dehumidifier
Low-humidity specifications
(ex. +5°C/5%rh)
Chamber with a capacity greater than Type 12 (standard specification) may be ordered.
Custom shape and size
Adjustable height.
Shielding to eliminate electromagnetic noise that can be generated outside or inside the chamber
Shield installation
(radio wave insulation).
Chamber without floor panel The floor of the structure may become the floor of the chamber to allow heavy objects.
Outdoor air cooling specification Refrigerator may be installed outside the building.
Low VOC specification VOC concentration measurement
Noise-reduction specification A sound-absorbing unit may be installed to reduce noise.
Increased safety specification Pressure relief vent, fire extinguishing equipment, gas detectors, etc.
Refrigerant
pipes
*Image
11
SPECIFICATIONS
Walk-in Type Temperature & Humidity Chamber Walk-in Type Temperature Chamber
Model
EBE EBL EBR EBF EBU EBUU
Balanced Temperature and Humidity Control system (BTHC system)
System Balanced Temperature Control system (BTC system)
Vapor pressure divide control system
Allowable ambient conditions 0 to +40°C/up to 75% rh
–40 to +80°C –30 to +80°C –10 to +80°C –40 to +80°C –30 to +80°C –10 to +80°C
Temp. range*2
(–40 to +176°F) (–22 to +176°F) (+14 to +176°F) (–40 to +176°F) (–22 to +176°F) (+14 to +176°F)
10 to 95%rh 20 to 95%rh
Humid. range*2 –
(at +10 to +80°C) (at +20 to +80°C)
Performance*1
100
95
80
Frost-free range
60
Humidity
(%rh)
40
20
Frosting range
0 10 20 30 40 50 60 70 80 90
Temperature (°C)
EBL EBR
EBE
12
SAFETY DEVICES
13
OPTIONS
Indicates three chamber states: A mush room-head button installed to The alarm lamp and buzzer is activated to
OPERATION, PERSONNEL INSIDE, and protect workers who enter the temperature infor m the operators when the preset
ALARM. ( hu m id it y) ch a mb e r. W he n pr e s se d , working time limit is over.
chamber operation stops and the safety
buzzer issues an alarm.
Intercom
Cold-weather suit
Personnel indicator
We provide a set of protective clothing
Indicates "PERSONNEL INSIDE" when including headwear, a pair of gloves, a pair
workers have entered the temperature of boots and a two-piece suit. (For use in
(humidity) chamber. chamber under –40°C)
Grounding terminal
Alarm indicator
Leakage detector
A grounding terminal for test equipment
I n d i c a t e s "A L A R M " i n r e d w h e n a
used inside the temperature (humidity) Detects leakage with the leakage sensor.
chamber fault occurs.
chamber.
14
OPTIONS
Records the temperature of each section No. 1 –50 to +100°C 100 mm Adds additional terminals to the standard
such as the temperature inside the chamber. 6-dot system time signal terminals.
The data can be transferred by USB. No. 2 –50 to 100°C/
Scan interval: 5 sec. 0 to 100%rh 100 mm
Internal recording media: 6-dot system Remote control function
Flash memory 8MB
External recording media: Te st c ond it ion s c a n b e ch a nge d a nd
CF memory card port operation can be started or stopped from
(Includes a 256MB CF card) your PC over an Ethernet connection.
USB memory port (Web browser)
Lang uages: Can be switched bet ween
English/Japanese
<Temperature type>
Temperature range: –50 to +100°C
–100 to +100°C
100 mm
–50 to +150°C
–100 to +200°C
Number of inputs: Temperature 1
(5 more channels can Recorder output terminal
be turned OFF) Run/stop operation
This terminal outputs the temperature and
<Temperature and humidity type>
relative humidity in the test area.
Temperature range: –50 to +100°C
–100 to +100°C Interface
–50 to +150°C Humidity sensor (for temperature &
–100 to +150°C humidity chambers only) C om mu n ic at ion p or t t o c on ne c t t he
Humidity range: 0 to 100%rh chamber to a PC.
Number of inputs: Temperature 1/ Eliminates the need to change wicks and • RS-485
Humidity 1 can accommodate a range of measure- • RS-232C
(4 more channels can ments impossible with a dry bulb sensor, • GPIB
be turned OFF) including low humidity ranges.
Communication cable
Thermocouple
• RS-485 5m/ 10m/ 30m
Used for arbitrary temperature measure- • GPIB 2m/ 4m
m e n t p oi n t s i n sid e t h e t e m p e r a t u r e
(humidit y) chamber or measuring the
specimen temperature. Additional cable port
ø50 mm
15
OPTIONS
The standard window (W180×H289 mm) • L ED (adds the same as the standard The standard single door (W850 × H1800
can be changed to a larger type (W440× accessory) mm) can be changed for a double swing
H295 mm). Tempered heat-resistant glass • F l u o r e s c e n t l a m p, ON w h e n r o o m door (W1400 × H1800 mm).
with defogging heater. temperature is +5°C to +40°C
• Incandescent lamp
Floor reinforcement
Additional door
Viewing window Protective flooring (rubber type) ファン
(installed on chamber
試験室 wall) Two types are available:
凝縮器
single-swing and
Prevents operators f rom slipping and double-swing doors. Both come with a
Two viewing windows are available: prevents damage and dents. viewing window (W180
冷水槽× H289 冷却水mm).
配管
• Small (W350 × H250 mm)予備室 補給水
冷凍機
• Large (W600 × H400 mm)
Heat proof rei nforced glass with heat Full-ceiling air duct Entrance curtain ポンプ
Lowers and stabilize air circulation speed Prevents atmospheric disturbance of temp.
to protect specimen. and humid. within the chamber when
Hand-in ports opening and closing the door.
(with viewing window W350 × H 250 mm)
Test area
Insertion ramp
Frost-free expansion (temperature Water purifier (for temperature & Flow switch
& humidity chamber only) humidity chambers only) (for water-cooled models only)
Expands the temperature and humidity Connects to the steam humidif ier and This safety switch for refrigeration unit
control range on the low temperature side optional auxiliary humidifiers. Improves activates when the cooling water level
and increases continuous operation time the reliability of measurements over long becomes too low or cut off, and shuts
by preventing frost formation. periods of time and extends the life of the down the equipment.
humidifiers.
•R e ve r s e o s m o s i s m e m b r a n e w a t e r
Airflow adjuster purifier Exhaust air duct
• Ion-exchange water purifier (for air-cooled type)
Used when tests requi re low ai r f low
velocity or a constant velocity. Exhausts hot air out of the refrigeration
Setting value range: 4 levels system. Installed on the upper part of the
machinery compartment.
fan
Condenser
Pump
Drain
17
Safety precautions
● Do not use specimens which are explosive or inflammable, or which contain such
substances.
To do so could be hazardous, as this may lead to fire or explosion.
● Do not place corrosive materials in the chamber. If corrosive substances or liquid
is used, the life of the unit may be significantly shortened specifically because of
the corrosion of stainless steel, resin and silicone materials.
● Do not place life forms or substances that exceed allowable heat generation.
● Be sure to read the operation manual before operation.
18
http://www.espec.co.jp/english
Head Office
3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan
Tel : 81-6-6358-4741 Fax : 81-6-6358-5500