You are on page 1of 27

CORE WALLS AND SHEAR WALLS

ITEM LENGTH WIDTH HEIGHT NO OF FORMWORK VOLUME


DESCRIPTION/GRID
NO. (m) (m) (m) FLOOR (Sq.m) (M3)

GROUND FLOOR
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

BILL NO. 2 SECTION - 1 CONCRETE WORK

Rate
Item Description Qty Unit
(AED)
Note
The contractor shall strictly follow and comply with
the QCE in regard to this scope of work.

SUB-STRUCTURE CONCRETE
Plain in-situ concrete Grade 30 OPC.

Provision of concrete designed mix concrete, Grade


C30 OPC, maximum aggregate size 40 mm mix
cement content 400 Kg/m3. including tests, quality
control procedures, compaction, curing, etc.

Placing of concrete for piles Dia. 600, 750, 900,


A 305 m3
1000 mm piles

Placing of reinforced concrete for pile caps


B 658 m3
thickness exceeding 500 mm

Plain in-situ concrete Grade 20 OPC.


Provision of concrete designed mix concrete, Grade
C20 OPC, maximum aggregate size 40 mm mix
cement content 400 Kg/m3. including tests, quality
control procedures, compaction, curing, etc.

Placing of mass blinding concrete for pile caps,


C 856 m3
thickness not exceeding 150 mm

BILL OF QUANTITIES
2
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

CARRIED TO COLLECTION
AED

COLLECTION

From Page BOQ 2 - 01/01

BILL OF QUANTITIES
3
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

TOTAL FOR BILL NO.2 SECTION - 1 CONCRETE WORKS CARRIED TO


SUMMARY AED

BILL OF QUANTITIES
4
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

Amount
AED)

BILL OF QUANTITIES
5
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

BILL OF QUANTITIES
6
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

BILL OF QUANTITIES
7
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

BILL NO. 2 SECTION - 2 CONCRETE ANCILLARIES

Rate Amount
Item Description Qty Unit
(AED) AED)
Note
The contractor shall strictly follow and comply with
the QCE in regard to this scope of work.

SUB-STRUCTURE FORMWORK
Formwork for pile caps with fair finishes and plan
vertical including support tems and etc.

A Width exceeding 1.22 m 856 m2 0

B Width 0.4 - 1.22 m 34 m2 0

SUB-STRUCTURE REINFORCEMENT
High strenght tor steel reinforcement, plan round
steel bars, strength characteristic 460 N/mm2

C nominal size 12 mm dia. 5.3 t 0


D nomial size 16 mm dia. 3.9 t 0
E nomial size 20 mm dia. 26.4 t 0
F nominal size 25 mm dia. 5.1 t 0
G nominal size 32 mm dia. 26.5 t 0

CARRIED TO COLLECTION
AED 0
BILL OF QUANTITIES
8
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1
CARRIED TO COLLECTION
AED 0

BILL OF QUANTITIES
9
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

COLLECTION

From Page BOQ 2 - 02 /01

BILL OF QUANTITIES
10
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

TOTAL FOR BILL NO.2 SECTION - 2 CONCRETE ANCILLARIES CARRIED


TO SUMMARY AED

BILL OF QUANTITIES
11
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

BILL NO. 2 SECTION - 3 PILES AND PILING ANCILLARIES

Rate
Item Description Qty Unit
(AED)
Note
The contractor shall strictly follow and comply with
the QCE in regard to this scope of work.

SUB-STRUCTURE PILES
Provide transport for piling plant and equipment to
site, setting up, dismantling and removing until
completion 1 Item

Bored cast in place insitu concrete reinforcement


concrete piles grade 30 including disposal of
excavated materials.

(a) - number of piles


A number of piles dia. 600-750 mm 20 Nr.
B number of piles dia. 900-1050 mm 28 Nr.

(b) - concrete depth / length


C concrete depth dia. 600-750 mm 202 m
D concrte depth dia. 900-1050 mm 270 m

(C) - depth of bored


E depth of bored dia. 600-750 mm 222 m
F depth of bored dia. 900-1050 mm 311 m

G Disposal
Remove disposal of excavated material from pile
operation area at boring time, including loading and
unloading at off site 3250 m3

SUB-STRUCTURE PILING ANCILLARIES


Piling ancillaries cast in place concrete piles

Pre - boring
H dia. 600-750 mm 222 m
I dia. 900-1050 mm 311 m

Cutting of surplus length


J dia. 600-750 mm 40 m
K dia. 900-1050 mm 42 m

BILL OF QUANTITIES
12
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

Prepaing heads
L dia. 600-750 mm 20 Nr.
dia. 900-1050 mm 28 Nr.

CARRIED TO COLLECTION
AED

BILL OF QUANTITIES
13
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

Rate
Item Description Qty Unit
(AED)

Reinforcement
Piling ancillaries cast in place concrete piles
reinforcement at bored piles, High strenght tor steel
reinforcement, plan round steel bars, strength
characteristic 460 N/mm2 straight bars

M nominal size not exceeding 25 mm but used bar dia.


20 mm only 0.9 t
N nominal size exceeding 25 mm but used bar dia. 25
mm only 181.1 t

Piling ancillaries cast in place concrete piles


reinforcement at bored piles, mild steel steel
reinforcement helical bars stated, strength
characteristic 250 N/mm2

O
helical bars binding for piles in 10 mm nominal size 3.5 t

Obstructions

P Piling ancillaries obstructions doing for pre boring at


rock 150 mm per hour 322 h

Piling Tests

Q
Piling tests, horizontal loading, test load 600 - 800 t 48 Nr

BILL OF QUANTITIES
14
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

CARRIED TO COLLECTION
AED

BILL OF QUANTITIES
15
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

COLLECTION

From Page BOQ 2-03/01


From Page BOQ 2-03/02

BILL OF QUANTITIES
16
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

TOTAL FOR BILL NO.2 SECTION - 3 PILES AND PILING ANCILLARIES


CARRIED TO SUMMARY AED

BILL OF QUANTITIES
17
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

Amount
AED)

0
0

0
0

0
0

0
0

0
0

BILL OF QUANTITIES
18
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

0
0

BILL OF QUANTITIES
19
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

Amount
AED)

BILL OF QUANTITIES
20
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

BILL OF QUANTITIES
21
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

BILL OF QUANTITIES
22
PROPOSED CANCER RADIATION TREATMENT CENTER - PHASE 1

BILL OF QUANTITIES
23
PILE ANCILLARIES

Rate
Item Description Qty Unit
(AED)
Note
The contractor shall strictly follow and comply with
the QCE in regard to this scope of work.

SUB-STRUCTURE PILING ANCILLARIES


Piling ancillaries cast in place concrete piles

Pre - boring
A dia. 600-750 mm 222 m
B dia. 900-1050 mm 311 m

Cutting of surplus length


C dia. 600-750 mm 40 m
D dia. 900-1050 mm 42 m

Prepaing heads
E dia. 600-750 mm 20 Nr.
dia. 900-1050 mm 28 Nr.

Reinforcement
Piling ancillaries cast in place concrete piles
reinforcement at bored piles, High strenght tor steel
reinforcement, plan round steel bars, strength
characteristic 460 N/mm2 straight bars

nominal size not exceeding 25 mm but used bar dia.


F 20 mm only 0.9 t
nominal size exceeding 25 mm but used bar dia. 25
G mm only 181.1 t

Piling ancillaries cast in place concrete piles


reinforcement at bored piles, mild steel steel
reinforcement helical bars stated, strength
characteristic 250 N/mm2

H helical bars for piles in 10 mm nominal size 3.5 t

Obstructions
Piling ancillaries obstructions doing for pre boring at
I rock 150 mm per hour 322 h
Piling Tests

J
Piling tests, horizontal loading, test load 600 - 800 t 48 Nr

CARRIED TO COLLECTION