You are on page 1of 444

TOLL FREE 1.800.342.7215 | 1.954.455.3050 | sales@buyawg.com | www.buyawg.

com

YOUR SINGLE SOURCE FOR WIRE AND CABLE PRODUCTS

GROUNDING CABLES/ TRANSMISSION & MULTIPLEX LOW VOLTAGE MEDIUM VOLTAGE ARMORED CONTROL OPGW/FIBER PORTABLE POWER
STATIC & GUY WIRE DISTRIBUTION CABLES CABLES CABLES CABLES CABLES CABLES OPTIC CABLES CABLES

POWERFUL & ECONOMICAL WIRE & CABLE SOLUTIONS FOR...


TRANSMISSION & DISTRIBUTION WINDPOWER APPLICATIONS SOLAR APPLICATIONS
STATIC WIRE/GUY WIRE
GROUNDING CABLES/
GROUNDING, STATIC & GUY WIRE
Table of Contents

Grounding Cables
Bare Copper ........................................................................................................................101
Tinned Copper ....................................................................................................................102
Trolley Wire Copper............................................................................................................103
Copperclad Steel Wire........................................................................................................104
Tracer Wire Polyethylene Insulated Copperclad Steel ....................................................109
Static & Guy Wire
Alumoclad Steel Wire.........................................................................................................105
Type M Alumoclad Steel Wire Guy Strand ......................................................................106
Galvanized Guy Wire/Static Wire.......................................................................................107
Copper Clad Ground Rods.....................................................................................................110
Bronze Ground Rod Clamps#.................................................................................................111

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 100
Copyright © 2018, American Wire Group, Inc. 20180201
STATIC WIRE/GUY WIRE
GROUNDING CABLES/

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
STATIC WIRE/GUY WIRE
GROUNDING CABLES/
Bare Copper

Applications
Used for overhead electrical distribution lines, grounding electrical substations, electrical test
equipment and any other electrical system. Suitable for numerous other applications.

Specifications
ASTM Specifications, latest issue, as follows:
Solid
• ASTM B-1 Hard Drawn Temper
• ASTM B-2 Medium Hard Drawn Temper
• ASTM B-3 Soft Drawn Temper
Stranded
• ASTM B-1 Hard Drawn Temper
• ASTM B-2 Medium Hard Drawn Temper
• ASTM B-3 Soft Drawn Temper
• ASTM B-8 - Concentric Lay, All Tempers
Notes
Ampacities (Amps per Conductor) are based on a 30°C ambient temperature, single conductor in
air, per NEC.

Item # Size Number Overall Weight Allowable Breaking Breaking Breaking


AWG of Strands Diameter /MFT Amps per Strength – Strength – Strength –
or KCMIL (in) (lb) Conductor Soft Medium Hard
(lb) (lb) (lb)
SCC-01 14 Solid 0.064 12.43 32 124.2 166.6 213.5
SCC-02 12 Solid 0.081 19.77 41 197.5 261.2 336.9
SCC-03 10 Solid 0.102 31.43 68 314 410.4 529.2
SCC-04 8 Solid 0.129 49.98 95 479.8 643.9 826
SCC-05 6 Solid 0.162 79.46 125 762.9 1010 1280
SCC-06 4 Solid 0.204 126.40 170 1213 1584 1970
SCC-07 2 Solid 0.258 200.90 225 1928 2450 3002
STC-01 8 7 0.146 51.0 95 499 610 777
STC-02 6 7 0.184 81.1 130 794 959 1228
STC-03 4 7 0.232 128.9 170 1320 1505 1938
STC-04 2 7 0.292 204.9 230 2110 2360 3050
STC-05 1 7 0.332 258.4 265 2552 2995 3801
STC-06 1/0 7 0.373 325.8 310 3221 3705 4752
STC-06a 1/0 19 0.373 325.8 310 3221 3705 4752
STC-07 2/0 7 0.419 410.9 355 4062 4640 5926
STC-07a 2/0 19 0.419 410.9 355 4062 4640 5926
STC-08 3/0 7 0.470 518.1 410 5074 5970 7698
STC-08a 3/0 19 0.470 518.1 410 5074 5970 7698
STC-09 4/0 7 0.528 653.3 480 6453 7479 9617
STC-09a 4/0 19 0.528 653.3 480 6453 7479 9617
STC-10 250 19 0.575 771.9 530 7940 8952 11600
STC-11 300 37 0.630 926.3 590 9160 10530 13510
STC-12 350 37 0.681 1081.0 650 10580 12450 16060
STC-14 500 37 0.813 1544.0 810 15240 17550 22510
STC-15 600 61 0.893 1853.0 910 18300 21060 27020
STC-16 750 61 0.998 2316.0 1040 22890 26510 34090
STC-17 1000 61 1.152 3088.0 1240 30500 35100 45030

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 101
Copyright © 2018, American Wire Group, Inc. 20140110
STATIC WIRE/GUY WIRE
GROUNDING CABLES/

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
STATIC WIRE/GUY WIRE
GROUNDING CABLES/
Tinned Copper

Applications
Used for overhead electrical distribution lines, grounding electrical substations, electrical test
equipment and any other electrical system. Suitable for numerous other applications.

Specifications
ASTM Specifications, latest issue, as follows:
Solid
• ASTM B-3 Soft Drawn Temper
• ASTM B-33 Tinned, Soft or Annealed Copper Wire
Stranded
• ASTM B-8 Concentric Lay, All Tempers Tinned
• ASTM B-33 Tinned, Soft or Annealed Copper Wire
Notes
Ampacities (Amps per Cond.) are based on a 30°C ambient temperature, single conductor in air, per
NEC.

Item # Size Number Overall Weight Allowable Breaking


AWG of Strands Diameter /MFT Amps per Strength –
or KCMIL (in) (lb) Conductor Soft
(lb)
SCC-T-01 14 Solid 0.064 12.43 32 124.2
SCC-T-02 12 Solid 0.081 19.77 41 197.5
SCC-T-03 10 Solid 0.102 31.43 68 314
SCC-T-04 8 Solid 0.129 49.98 95 479.8
SCC-T-05 6 Solid 0.162 79.46 125 762.9
SCC-T-06 4 Solid 0.204 126.4 170 1213
SCC-T-07 2 Solid 0.258 200.9 225 1928
STCC-T-01 8 7 0.146 51.0 95 499
STCC-T-02 6 7 0.184 81.1 130 794
STCC-T-03 4 7 0.232 128.9 170 1320
STCC-T-04 2 7 0.292 204.9 230 2110
STCC-T-05 1 7 0.332 258.4 265 2552
STCC-T-06 1/0 7 0.373 325.8 310 3221
STCC-T-06a 1/0 19 0.373 325.8 310 3221
STCC-T-07 2/0 7 0.419 410.9 355 4024
STCC-T-07a 2/0 19 0.419 410.9 355 4024
STCC-T-08 3/0 7 0.470 518.1 410 5118
STCC-T-08a 3/0 19 0.470 518.1 410 5074
STCC-T-09 4/0 7 0.528 653.3 480 6459
STCC-T-09a 4/0 19 0.528 653.3 480 6453
STCC-T-10 250 19 0.575 771.9 530 7627
STCC-T-11 300 37 0.630 926.3 590 9160
STCC-T-12 350 37 0.681 1081.0 650 10580
STCC-T-14 500 37 0.813 1544.0 810 15240
STCC-T-15 600 61 0.893 1853.0 910 18300
STCC-T-16 750 61 0.998 2316.0 1040 22890
STCC-T-17 1000 61 1.152 3088.0 1240 30500

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 102
Copyright © 2018, American Wire Group, Inc. 20170925
STATIC WIRE/GUY WIRE
GROUNDING CABLES/

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
STATIC WIRE/GUY WIRE
GROUNDING CABLES/
Trolley Wire
Copper

Applications
Trolley wire is used as an overhead power source for electric railroad locomotives, cranes, light rail
transit systems, and underground mining motor cars.

Construction
Single conductor, solid copper, having a hard drawn temper, made in the configurations of: round,
grooved, figure 8 or figure 9 deep section. Special alloys available.

Specifications
• ASTM B-47

Item # Nominal Overall Overall Area Area Area Weight Weight Weight Tensile Tensile Resist. Resist. Resist. Min. Min.
Conductor Diameter Diameter Circular (in2) (mm2) /MFT /mile /km Strength Strength (68°- (68°- (68°- Break. Break.
Size (in) (mm) (lb) (lb) (kg) (lb/in2) (kg/mm2) 20°C) 20°C) 20°C) Strength Strength
/MFT /mile /km (lb) (kg)
(ohm) (ohm) (ohm)
Round
R 1/0 1/0 AWG .3249 8.252 105600 .0829 53.5 319.5 1687 475 54.5 38.3 .1011 .53381 .33177 4518 2049
R 2/0 2/0 AWG .3648 9.266 133100 .1045 67.4 402.8 2127 599 52.8 37.1 .08021 .42351 .26321 5519 2503
R 3/0 3/0 AWG .4096 10.404 167800 .1318 85.0 507.8 2681 755 51.0 35.9 .06362 .33591 .20877 672 3048
R 4/0 4/0 AWG .4600 11.684 211600 .1622 107.2 640.5 3382 953 49.0 34.5 .05405 .26638 .16556 8143 3694
R 300 300 MCM .5477 13.911 30000 .2356 152.0 908.0 4794 1350 46.4 32.6 .03558 .18786 .11676 10930 4958
Grooved
G 2/0 2/0 AWG .392 9.956 137900 .1083 69.9 417.4 2204 621 50.2 35.3 .07741 .40872 .25402 5437 2466
G 3/0 3/0 AWG .430 10.922 167300 .1314 84.8 506.4 2674 753 48.5 34.1 .06380 .33686 .20936 6373 2891
G 4/0 4/0 AWG .482 12.243 212000 .1665 107.4 641.7 3388 955 46.6 32.8 .05035 .26585 .16523 7759 3519
G 300 300 MCM .574 14.580 299800 .2355 151.9 907.5 4792 1350 44.2 31.1 .03560 .18797 .11682 1041 4722
G 350 350 MCM .620 15.748 351200 .2758 177.9 1063.0 5613 1582 42.8 30.1 .03039 .16046 .09973 11810 5357
Figure 8
F8 1/0 1/0 AWG .420x.312 10.7x7.9 105600 .0829 53.5 319.7 1687 475 51.8 36.4 .1011 .53381 .33177 4296 1949
F8 2/0 2/0 AWG .480x.352 12.2x8.9 133100 .1045 67.4 402.9 2127 599 50.2 35.3 .08020 .42346 .26318 5248 238
F8 4/0 4/0 AWG .600x.450 15.2x11.1 211600 .1662 107.2 640.5 3382 953 46.6 32.8 .05045 .26638 .16556 7744 3513
F8 300 300 MCM .754x.570 19.2x14.5 350100 .2750 177.4 1060.0 5595 1577 42.8 30.1 .03049 .16099 .10001 11700 5339
Deep Section
F9 350 350 MCM .707x.496 17.9x12.6 348900 .2740 176.8 1056.0 5576 1571 42.8 30.1 .03059 .16152 .10039 11730 5321
F9 400 400 MCM .715x.522 18.9x14.0 397200 .3120 201.3 1202.0 6348 1789 41.3 29.0 .02687 .14187 .08817 12880 5842

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 103
Copyright © 2018, American Wire Group, Inc. 20140110
STATIC WIRE/GUY WIRE
GROUNDING CABLES/

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
STATIC WIRE/GUY WIRE
GROUNDING CABLES/
Copperclad
Steel Wire

Applications
Copperclad steel wire and strand combines the electrical characteristics of copper with the mechani-
cal properties of steel. Often used for buried ground grid systems, overhead ground wire and mes-
senger wire, it can resist mechanical damage during installation, as well as electrical damage
during a fault condition.
Copperclad steel has virtually no scrap value, greatly reducing the potential of theft.

Construction
Dead Soft Annealed (DSA) Copperclad Steel (CCS) conductors are a concentric lay-stranded con-
struction. The CCS strands are a 40% conductivity grade of material using a low carbon steel core
rendering greater flexibility to enable easier handling during installation

Specifications
CCS bare conductors meet or exceed the following ASTM specifications:
• B-193 Standard Test Method for Resistivity of Electrical Conductor Materials
• B-227 Standard Specification for Hard-Drawn Copperclad Steel Wire
• B-228 Standard Specification for Concentric-Lay-Stranded Copperclad Steel Conductors
• B-258 Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG
Sizes of Solid Round
• B-910 Standard Specification for Annealed Copperclad Steel Wire
• Wires Used as Electrical Conductors
Note
The ampacity rating and the DC and AC resistance of the Copperclad Steel wire conductor is not
equivalent to that of copper conductor.
To select the correct equivalent please see the chart below.

Diameter Comparison for Copper Equivalent Fusing Current for Grounding Applications
Copper Clad Steel Copper Product Copper Product Copper Clad Steel
40% DSA SIZE DIAMETER 40% DSA
SIZE (in) DIAMETER
(in)
#6 SOLID #6 SOLID 0.162 0.162
#4 SOLID #4 SOLID 0.204 0.204
7 #9 40% DSA #2 7W 0.292 0.343
7 #8 40% DSA 1 SOLID 0.289 0.385
7 #7 40% DSA 1/0 7W 0.368 0.433
7 #6 40% DSA 2/0 7W 0.414 0.486
7 #5 40% DSA 3/0 7W 0.464 0.546
19 #9 40% DSA 4/0 7W 0.552 0.572
19 #8 40% DSA 250 12W 0.574 0.642
19 #7 40% DSA 300 19W 0.629 0.721
19 #6 40% DSA 400 19W 0.726 0.810
19 #5 40% DSA 500 19W 0.813 0.910

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 104
Copyright © 2018, American Wire Group, Inc. 20180201
STATIC WIRE/GUY WIRE
GROUNDING CABLES/

Copperclad
Steel Wire

Item # Nominal Nominal Number Diameter Nominal Maximum Minimum Nominal


Cross- Cross- of of Overall Resistance Breaking Weight
Sectional Sectional Wires Wires Diameter DC@20°C Strength (lb/ft)
Area Area (in) Ohm (lb)
(c) (mm2) (M/ft)
7#9 0.07195 46.42 7 0.1144 0.343 0.2916 2650 0.259
7#8 0.09078 58.57 7 0.1285 0.385 0.2311 3350 0.327
7#7 0.1145 73.86 7 0.1443 0.433 0.1833 4220 0.413
7#6 0.1443 93.09 7 0.162 0.486 0.1454 5320 0.52
7#5 0.1819 117.40 7 0.1819 0.546 0.1153 6710 0.656
19#9 0.1953 126.00 19 0.1144 0.572 0.1079 6820 0.707
19#8 0.2464 159.00 19 0.1285 0.642 0.0855 8610 0.892
19#7 0.3107 200.50 19 0.1443 0.721 0.0678 10850 1.125
19#6 0.3916 252.70 19 0.162 0.81 0.0527 13680 1.418
19#5 0.4938 318.50 19 0.1819 0.91 0.0418 17250 1.787

APPROXIMATE FUSING CURRENTS for 40% COPPER CLAD STEEL


Approximate Fusing Current (A)

Time to Fuse (seconds)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
104 Information on this sheet subject to change without notice.
20180201 Copyright © 2018, American Wire Group, Inc. Hallandale, Florida
STATIC WIRE/GUY WIRE
GROUNDING CABLES/
Copperclad
Steel Wire

Approximate Short Term Fusing Currents for 40% CCS (amps)


40% DSA Copper Clad Steel for Grounding Applications
Time Cycles 19 19 19 19 19 19 7 7 7 7 7 7 Solid Solid Solid
(sec) No. 5 No. 6 No. 7 No. 8 No. 9 No. 4 No. 5 No. 6 No. 7 No. 8 No. 9 No. 10 No. 2 No. 4 No. 6
628,917 498,762 395,542 313,684 248,767 292,171 231,706 183,754 145,726 115,568 91,651 72,683 66,365 41,738 26,250
CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL
0.05 3 330,426 262,044 207,814 164,807 130,700 153,504 121,736 96,543 76,563 60,718 48,152 38,187 34,867 21,929 13,792
0.1 6 233,647 185,293 146,947 116,536 92,419 108,543 86,080 68,266 54,138 42,934 34,049 27,002 24,655 15,506 9,752
0.2 12 165,213 131,022 103,907 82,403 65,350 76,752 60,868 48,271 38,281 30,359 24,076 19,094 17,434 10,965 6,896
0.3 18 134,896 106,979 84,840 67,282 53,358 62,668 49,698 39,413 31,257 24,788 19,658 15,590 14,235 8,953 5,630
0.4 24 116,823 92,647 73,473 58,268 46,209 54,272 43,040 34,133 27,069 21,467 17,024 13,501 12,328 7,753 4,876
0.5 30 104,490 82,866 65,716 52,116 41,331 48,542 38,496 30,529 24,211 19,201 15,227 12,076 11,026 6,935 4,361
0.6 36 95,386 75,646 59,991 47,576 37,730 44,313 35,142 27,869 22,102 17,528 13,900 11,024 10,065 6,330 3,981
0.7 42 88,310 70,034 55,541 44,046 34,931 41,026 32,535 25,802 20,462 16,228 12,869 10,206 9,319 5,861 3,686
0.8 48 82,607 65,511 51,953 41,202 32,675 38,376 30,434 24,136 19,141 15,180 12,038 9,547 8,717 5,482 3,448
0.9 54 77,882 61,764 48,982 38,845 30,806 36,181 28,693 22,755 18,046 14,311 11,350 9,001 8,218 5,169 3,251
1 60 73,886 58,595 46,469 36,852 29,225 34,324 27,221 21,588 17,120 13,577 10,767 8,539 7,797 4,903 3,084
2 120 52,245 41,433 32,858 26,058 20,665 24,271 19,248 15,265 12,106 9,600 7,614 6,038 5,513 3,467 2,181
The most economical choice is to replace dead soft annealed (DSA) copper with DSA copper clad steel for grounding applications (downpole and mats).
Below are a few of the major advantages:
Life Equivalent to copper in corrosion resistance
Fatigue Resistance Superior to annealed copper
Handling Flexible and manageable like copper, yet more robust and durable than dead soft annealed copper
Mechanical Higher mechanical strengths minimize physical damage during installation and service
Weight Lighter than copper by 8.5% for equivalent sizes
Theft Resistance Zero scrap value

COMPARISON: Approximate Short Term Fusing Currents for Copper (amps)


Time Cycles 500 400 300 250 4/0 3/0 2/0 1/0 Solid Solid Solid Solid Solid
(sec) MCM MCM MCM MCM Strand Strand Strand Strand No. 1 No. 2 No. 4 No. 6 No.
500,000 400,000 300,000 250,000 211,563 167,779 133,057 105,521 83,683 66,365 41,738 26,250 16,510
CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL
.05 3 317,543 254,034 190,526 158,771 134,361 106,555 84,503 67,015 53,146 42,148 026,508 16,671 10,485
0.1 6 224,537 179,629 134,722 112,268 95,007 75,345 59,753 47,387 37,580 29,803 18,744 11,788 7,414
0.2 12 158,771 127,017 95,263 79,386 67,180 53,277 42,251 33,508 26,573 21,074 13,254 8,336 5,243
0.3 18 129,636 103,709 77,782 64,818 54,853 43,501 34,498 27,359 21,697 17,207 10,822 6,806 4,281
0.4 24 112,268 89,815 67,361 56,134 47,504 37,673 29,876 23,693 18,790 14,901 9,372 5,894 3,707
0.5 30 100,416 80,333 60,249 50,208 42,489 33,696 26,722 21,192 16,806 13,328 8,382 5,272 3,316
0.6 36 91,667 73,333 55,000 45,833 38,787 30,760 24,394 19,346 15,342 12,167 7,652 4,813 3,027
0.7 42 84,867 67,893 50,920 42,433 35,909 28,478 22,584 17,911 14,204 11,264 7,084 4,456 2,802
0.8 48 79,386 63,509 47,631 39,693 33,590 26,639 21,126 16,754 13,287 10,537 6,627 4,168 2,621
0.9 54 74,846 59,876 44,907 37,423 31,669 25,115 19,918 15,796 12,527 9,934 6,248 3,929 2,471
1 60 71,005 56,804 42,603 35,502 30,044 23,826 18,895 14,985 11,884 9,424 5,927 3,728 2,345
2 120 50,208 40,166 30,125 25,104 21,244 16,848 13,361 10,596 8,403 6,664 4,191 2,636 1,658

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 104
Copyright © 2018, American Wire Group, Inc. 20180201
STATIC WIRE/GUY WIRE
GROUNDING CABLES/

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
STATIC WIRE/GUY WIRE
GROUNDING CABLES/
Tracer Wire Polyethelene Insulated
Copperclad Steel

Description
HMW polyethylene covered copperclad wire.

Application
Telephone and signal lines, alarm circuits, remote control, tree wire, and grounding wire.

Standards
ASTM-B228

Item# Conductor Size Wire Breaking DC Covering Appox OD Weight Weight


Type AWG Diameter Strength Resistance Thickness PE Covered /MFT /Mile
(High Strength (in) (lb) ohms/MFT (in) (in) (lb) (lb)
Conductivity) @68°
PCSC-6-30 30% 6 .1620 2680 1343 2/64 .225 80.3 424
PCSC-8-30 30% 8 .1285 1815 2136 2/64 .191 51.8 274
PCSC-9-30 30% 9 .1144 1491 2693 2/64 .177 41.7 220
PCSC-10-30 30% 10 .1019 1231 3396 2/64 .164 33.9 179
PCSC-6-40 40% 6 .1620 2433 1.008 2/64 .225 80.3 424
PCSC-8-40 40% 8 .1285 1660 1.602 2/64 .191 51.8 274
PCSC-9-40 40% 9 .1144 1368 2.020 2/64 .177 41.7 220
PCSC-10-40 40% 10 .1019 1130 2.547 2/64 .164 33.9 179
PCSC-12-40 40% 12 .08081 785 4.051 2/64 .143 22.3 118

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 109
Copyright © 2018, American Wire Group, Inc. 20140921
STATIC WIRE/GUY WIRE
GROUNDING CABLES/

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
STATIC WIRE/GUY WIRE
GROUNDING CABLES/
Alumoclad
Steel Wire

Application
Overhead ground wire, shield wire protecting transmission lines against lightning damage.

Construction
Alumoclad steel wire and strand is used by power utilities as well as formed wire and optical
ground wire manufacturers. alumoclad steel wire outlasts other options by as much as 200% in cor-
rosive environments, significantly lowering maintenance and replacement costs. When compared
to solid aluminum wire, alumoclad steel wire offers tremendous savings.
Alumoclad steel wire overhead ground wire has excellent corrosion resistance. Its strength and con-
ductivity remain unchanged in any atmosphere where aluminum is satisfactory, especially those
known to be corrosive from industrial or atmospheric conditions.
This assurance against corrosion is obtained through the application of a thick covering of pure alu-
minum which provides a substantial barrier of protective metal. The minimum cladding thickness of
alumoclad steel wire is 10% of the radius of the wire. the cladding has a continuous, strong metallic
bond to the steel core that will not crack or flake.
Alumoclad steel wire also provides strength greater than or equal to other overhead ground wires.
For commonly used wire sizes, the tensile strength of the individual wire can approach 200,000
pounds per square inch. When used in a strand for overhead ground wire, this high strength per-
mits greater span lengths, less sag and heavier loads under storm loading conditions.
Directly related to strength and sag performance is the lighter weight of alumoclad steel wire. Due
to its thick cladding of aluminum, alumoclad steel wire is 15% lighter that a steel strand of equiva-
lent size. This lighter weight, combined with high strength, permits alumoclad steel wire to be in-
stalled to the same sags as steel with correspondingly lower tensions and tower stresses on the
towers or supporting structures.

Specifications
• B415 Standard Specification for Hard-Drawn Aluminum-Clad Steel Wire
• B416 Standard Specification for Concentric-Lay-Stranded Aluminum-Clad Steel Conductors

Item # No. and Size Nominal Nominal Breaking Breaking Weight Weight Resistance Resistance Area Area
of Wire Diameter Diameter Load Load /MFT /km /MFT /km (in2) (mm2)
(in) (mm) (lb) (kg) (lb) (kg) @ 68°F @ 20°F
(ohm) (ohm)
ALUM-01 37 #5 1.270 32.30 142800 647900 2802 4170 .04247 .1394 .96152 620.60
ALUM-02 37 #6 1.130 28.80 120200 54500 2222 3307 .05356 .1757 .76264 492.20
ALUM-03 37 #7 1.010 25.70 100700 45690 1762 2623 .06754 .2216 .60509 390.30
ALUM-04 37 #8 .899 22.90 84200 38190 1398 2080 .08516 .2794 .47984 309.50
ALUM-05 37 #9 .801 20.30 66770 30290 1108 1649 .1074 .3523 .38032 245.50
ALUM-06 37 #10 .713 17.90 52950 24020 879 1308 .1354 .4443 .30174 194.70
ALUM-07 19 #5 .910 23.10 73350 33270 1430 2129 .08224 .2698 .49438 318.70
ALUM-08 19 #6 .810 20.60 61700 27990 1134 1688 .1037 .3402 .39163 252.70
ALUM-09 19 #7 .721 18.30 51730 23460 899.5 1339 .1308 .4290 .31073 200.40
ALUM-10 19 #8 .642 16.30 43240 19610 713.5 1062 .1649 .5409 .24641 158.90
ALUM-11 19 #9 .572 14.50 34290 15550 565.8 842.0 .2079 .6821 .19530 126.10
ALUM-12 19 #10 .509 12.90 27190 15550 448.7 667.7 .2622 .8601 .15495 99.96
ALUM-13 7 #5 .546 13.90 27030 12260 524.9 781.1 .2264 .7426 .18193 117.40
ALUM-14 7 #6 .486 12.40 22730 10310 416.3 619.5 .2803 .9198 .14435 93.10
ALUM-15 7 #7 .433 11.00 19060 8645 330.0 491.1 .3535 1.160 .11448 73.87
ALUM-16 7 #8 .385 9.78 15930 7226 261.8 389.6 .4458 1.463 .09077 58.56
ALUM-17 7 #9 .343 8.71 12630 5729 207.6 308.9 .5621 1.844 .07198 46.44
ALUM-18 7 #10 .306 7.76 10020 4545 164.7 245.1 .7088 2.325 .05708 36.83

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 105
Copyright © 2018, American Wire Group, Inc. 20140924
STATIC WIRE/GUY WIRE
GROUNDING CABLES/

Alumoclad
Steel Wire

Item # No. and Size Nominal Nominal Breaking Breaking Weight Weight Resistance Resistance Area Area
of Wire Diameter Diameter Load Load /MFT /km /MFT /km (in2) (mm2)
(in) (mm) (lb) (kg) (lb) (kg) @ 68°F @ 20°F
(ohm) (ohm)
ALUM-19 7 #11 .272 6.91 7945 3604 130.6 194.4 .8938 2.932 .04527 29.21
ALUM-20 7 #12 .242 6.16 6301 2858 103.6 154.2 1.127 3.697 .03590 23.16
ALUM-21 3 #5 .392 9.96 12230 5547 224.5 334.1 .5177 1.699 .07796 50.32
ALUM-22 3 #6 .349 8.87 10280 4663 178.1 265.0 .6528 2.142 .06185 39.90
ALUM-23 3 #7 .311 7.90 8621 3910 141.2 201.1 .8232 2.701 .04905 31.65
ALUM-24 3 #8 .277 7.03 72060 3269 112.0 166.7 1.038 3.406 .03890 25.10
ALUM-25 3 #9 .247 6.26 5715 2592 888.1 132.2 1.309 4.294 .03085 19.90
ALUM-26 3 #10 .220 5.58 4532 2056 704.3 104.8 1.651 5.415 .02446 15.78
ALUM-27 #4 .2043 5.19 5081 2305 936.3 139.3 1.222 4.009 .03278 21.15
ALUM-28 #5 .1819 4.62 4290 1946 742.5 110.5 1.541 5.056 .02599 16.77
ALUM-29 #6 .1620 4.12 3608 1637 588.8 87.62 1.943 6.375 .02062 13.30
ALUM-30 #7 .1443 3.67 3025 1372 466.9 69.48 2.450 8.038 .01635 10.55
ALUM-31 #8 .1285 3.26 2529 1147 370.3 55.11 3.089 10.13 .01297 8.368
ALUM-32 #9 .1144 2.91 2005 909 293.7 43.71 3.986 12.78 .01028 6.632
ALUM-33 #10 .1019 2.59 1590 721 232.9 34.66 4.912 16.12 .00816 5.261
ALUM-34 #11 .0907 2.30 1261 572 184.7 27.49 6.194 20.32 .00647 4.172
ALUM-35 #12 .0808 2.05 1000 454 146.5 21.80 7.811 25.63 .00513 3.309

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
105 Information on this sheet subject to change without notice.
20140924 Copyright © 2018, American Wire Group, Inc.
STATIC WIRE/GUY WIRE
GROUNDING CABLES/
Type M
Alumoclad Steel Wire
Guy Strand

Application
Power lines, telephone lines, railway signals, communication lines, towers, masts.

Construction
Type M alumoclad guy strand is an economical, corrosion resistant buying material for use on over-
head line structures. The thick cladding of aluminum on each wire protects the high-strength steel
core from rusting and subsequent loss of strength. Costly maintenance is eliminated and the origi-
nal safety factor of the guy is maintained throughout the life of the line.
The alumoclad steel wire used to make Type M guy strand is unique in that the aluminum cladding
thickness is guaranteed to be no less than 10% of the wire radius. Thus, a thick corrosion barrier that
is pure aluminum not zinc or and iron-aluminum alloy protects the steel core.
Another important feature of any coated or clad wire is the bond between the coating material and
the base metal. In the case of alumoclad steel wire, the aluminum cladding and steel core are joined
by a continuous ductile weld. This assures against cracking or separating of the protective alu-
minum form the steel core.
Type M alumoclad steel wire guy strand is easily handled and installed. It weighs less than any of
the other high-strength guying materials.

Specifications
• A474 Standard Specification for Aluminum-Coated Steel Wire Strand
• B415 Standard Specification for Hard-Drawn Aluminum-Clad Steel Wire
• B416 Standard Specification for Concentric-Lay-Stranded Aluminumclad Steel Conductors

Item # Designation Construction AWG Stranded Cross Breaking Weight


Nos. (Equiv.) Diameter Section Load /MFT
(in) (in) (in2) (lb) (lb)
AGM-1 4 MG3 3/0.102 3/10 AWG 0.220 0.0245 4,500 70.61
AGM-2 5 MG3 3/0.114 3/9 AWG 0.247 0.0306 5,600 88.18
AGM-3 6 MG 7/0.081 7/12 AWG 0.242 0.0361 6,300 104.1
AGM-4 6.6 MG 7/0.083 N/A 0.249 0.0379 6,600 109.3
AGM-5 7 MG3 3/0.128 3/8 AWG 0.277 0.0386 7,100 111.2
AGM-6 8 MG 7/0.191 7/11 AWG 0.272 0.0455 8,000 131.4
AGM-7 5/16 in. MG3 3/0.141 3/7 AWG 5/16 0.0495 8,400 142.7
AGM-8 10 MG 7/0.102 7/10 AWG 0.306 0.0572 10,000 165.1
AGM-9 5/16 in. MG 7/0.104 N/A 5/16 0.0595 10,400 171.6
AGM-10 11.5 MG 7/0.110 N/A 0.330 0.0665 11,600 192.0
AGM-11 12.5 MG 7/0.114 7/9 AWG 0.343 0.0714 12,500 206.2
AGM-12 3/8 in. MG 7/0.121 N/A 3/8 0.0792 13,800 228.0
AGM-13 14 MG 7/0.121 N/A 0.363 0.0805 14,100 232.2
AGM-14 16 MG 7/0.128 7/8 AWG 0.386 0.0901 16,000 260.0
AGM-15 18 MG 7/0.139 N/A 0.417 0.1062 18,000 306.6
AGM-16 7/16 in. MG 7/0.145 7/7 AWG 7/16 0.1156 18,700 333.6
AGM-17 20 MG 7/0.148 N/A 0.444 0.1204 20,000 347.5
AGM-18 1/2 in. MG 7/0.165 N/A 1/2 0.1497 22,900 432.0
AGM-19 25 MG 7/0.173 N/A 0.519 0.1645 25,000 474.8

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 106
Copyright © 2018, American Wire Group, Inc. 20140924
STATIC WIRE/GUY WIRE
GROUNDING CABLES/

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
STATIC WIRE/GUY WIRE
GROUNDING CABLES/
Galvanized
Guy Wire/Static Wire

Applications
Messenger Wire, Overhead Ground or Static Wire, Guy Wire.

Grades
Utilities, Common, Siemens-Martin, High Strength and Extra High Strength

Finish Coatings
Class A, B and C and Bezinal, a superior corrosive coating of 5% Aluminum and 95% Zinc.

Specifications
Including but not limited to:
• ASTM A-363 Zinc-Coated (Galvanized) Steel Overhead Ground Wire Strand
• ASTM A-475 Zinc-Coated Steel Wire Strand
• ASTM A-925 -5 % Aluminum-Mischmetal Alloy-Coated Steel Overhead Ground Wire Strand
• ASTM A-855 Zinc-5 % Aluminum-Mischmetal Alloy-Coated Steel Wire Strand
• ASTM A-640 Zinc-Coated Steel Strand for Messenger Support of Figure 8 Cable

Item # Strand Coated Number Approx. Utilities/ Common Siemens- High Extra-High Min. Min. Min.
Diameter Diameter of Wires Strand Specification Grade Martin Strength Strength Weight Weight Weight
(in) (in) per Strand Weight Grade Min. Min. Grade Min. Grade Min. Grade Min. of Coating of Coating of Coating
/MFT Breaking Breaking. Breaking Breaking Breaking CLASS A CLASS B CLASS C
(lb) Strength Strength Strength Strength Strength (lb) (lb) (lb)
(lb) (lb) (lb) (lb) (lb)
GW5-3/16-062 3/16 0.062 7 73 1150 1900 2850 3990 0.50 1.00 1.50
GW6-3/16-065 3/16 0.065 7 80 2400 — — — — 0.50 1.00 1.50
GW7-7/32-072 7/32 0.072 7 98 — 1540 2560 3850 5400 0.50 1.00 1.50
GW8-1/4-080 1/4 0.080 7 121 — 1900 3150 4750 6650 0.60 1.20 1.80
GW9-9/32-093 9/32 0.093 7 164 4600 2570 4250 6400 8950 0.70 1.40 2.10
GW10-5 /16-104 5/16 0.104 7 205 — 3200 5350 8000 11200 0.80 1.60 2.40
GW11-5 /16-109 5/16 0.109 7 225 6000 — — — — 0.80 1.60 2.40
GW12-3/8-120 3/8 0.120 7 273 11500 4250 6950 10800 15400 0.85 1.70 2.55
GW13-7/16-145 7/16 0.145 7 399 18000 5700 9350 14500 20800 0.90 1.80 2.70
GW14-1/2-165 1/2 0.165 7 517 25000 7400 12100 18800 26900 0.90 1.80 2.70
GW15-9/16-188 9/16 0.188 7 671 — 9600 15700 24500 35000 1.00 2.00 3.00
GW16-5/8-207 5/8 0.207 7 813 — 11600 19100 29600 42400 1.00 2.00 3.00
GW17-1/2-100 1/2 0.100 19 504 — 7620 12700 19100 26700 0.70 1.40 2.10
GW18-9/16-113 9/16 0.113 19 637 — 9640 16100 24100 33700 0.80 1.60 2.40
GW19-5/8-125 5/8 0.125 19 796 — 11000 18100 28100 40200 0.85 1.70 2.55
GW20-3/4-150 3/4 0.150 19 1155 — 16000 26200 40800 58300 0.90 1.80 2.70
GW21-7/8-177 7/8 0.177 19 1581 — 21900 35900 55800 79700 0.90 1.80 2.70
GW22-1-200 1 0.200 19 2073 — 28700 47000 73200 104500 1.00 2.00 3.00

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 107
Copyright © 2018, American Wire Group, Inc. 20160414
STATIC WIRE/GUY WIRE
GROUNDING CABLES/

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
STATIC WIRE/GUY WIRE
GROUNDING CABLES/
Copper Clad Ground Rods

Applications Meets the following industry standards:


Driven into the ground in construction process • ANSI/UL 467
for tower, substation, pole and necessary • ANSI/NEMA GR-1
grounding of all major projects. • CSA - Canadian Standard
• ANSI C33.8
Construction • Rural Utilities Service - RUS
High Carbon Steel with an electrolytically ap- • Steel - cold drawn ASTM-A-1080
plied copper finish in 1/2", 5/8", 3/4" and 1" di- - SAE 1010-1035 carbon steel
ameters in varying lengths. Accessory package - Tensile strength 80,000-100,000 PSI
is of a high quality bronze alloy to provide both - Steel Rockwell Hardness—B80 (minimum)
ground rod and accessory excellent electrode • Copper coating is a minimum of .010 inches,
quality. Available in single type and sectional meeting or exceeding UL and ANSI specifica-
ground rod style. tions.
Specifications • Company name, UL logo and/or CSA Logo,
UL Listed product with a .010" copper electro- control number, and part number are located
plated finish on high quality high carbon steel within 12" of the chamfered end of each rod.
to produce a corrosion resistant product in a • Pointed and sectional copperclad ground rods
wide variety of environment. in popular diameters and lengths are available
for immediate shipping: 1/2-, 5/8-, 3/4-, and 1-
inch diameters; 6-, 8-, and 10-foot lengths.
• Custom lengths can be produced for cus-
tomer's special requirements. Minimum quan-
tites required.

CATALOG NUMBER DIMENSIONS PACKAGED


Pointed Rods Sectional Rods Nominal Actual Length Thread Weight Sub/Master
Diameter Diameter (ft) UNC Length (lbs) Bundles
(in) +_.005 (in) (in)
^C126 1/2" .500" 6' 9/16" 1 1/16" 4.22 lbs. 5 /100
C128 1/2" .500" 8' 9/16" 1 1/16" 5.62 lbs. 5 /100
C1210† 1/2" .500" 10' 9/16" 1 1/16" 7.03 lbs. 5 /100
C585 5/8" .560" 5' 5/8" 1 3/16" 4.27 lbs. 5 /100
^C586 ^CS586 5/8" .560" 6' 5/8" 1 3/16" 5.12 lbs. 5 /100
C588 CS588 5/8" .560" 8' 5/8" 1 3/16" 6.83 lbs. 5 /100
C58813* 5/8" .560" 8' 5/8" 1 3/16" 6.83 lbs. 5 /100
C5810† CS5810† 5/8" .560" 10' 5/8" 1 3/16" 8.54 lbs. 5 /100
C581013* 5/8" .560" 10' 5/8" 1 3/16" 8.54 lbs. 5 /100
C5812 5/8" .560" 12' 5/8" 1 3/16" 10.3 lbs. 5 / 50
C348 CS348 3/4" .678" 8' 3/4" 1 1/8" 10.0 lbs. 3 / 60
C34813* 3/4" .678" 8' 3/4" 1 1/8" 10.0 lbs. 3 / 60
C3410† CS3410† 3/4" .678" 10' 3/4" 1 1/8" 12.5 lbs. 3 / 60
C341013* 3/4" .678" 10' 3/4" 1 1/8" 12.5 lbs. 3 / 60
C110† CS110 1" .912" 10' 1" 1 1/8" 22.51 lbs. 25
^ Not UL Listed
† CSA - Canadian Standard
* Rural Utilities Services accepted (RUS) – 15 mil average, 13 mil minimum copper coating

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 110
Copyright © 2018, American Wire Group, Inc. 20180201
STATIC WIRE/GUY WIRE
GROUNDING CABLES/

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
STATIC WIRE/GUY WIRE
GROUNDING CABLES/
Bronze Ground Rod Clamps

Bronze Ground Rod Clamps Lay-in Clamps


• UL and CSA listed • For rebar applications
• High-strength corrosion-resistant copper alloy • UL listed for direct burial in earth or concrete
and/or stainless steel • Fits 1/2" to 1" rebar or ground rods
• Suitable for direct burial in earth or concrete • Wire size range #10 to #2
• Made in USA • Used extensively for grounding to rebar in
concrete
ALSO AVAILABLE
Universal Grounding Clamps Drive Ground (Drive-on) Clamps
• UL and CSA listing for direct burial in earth or • 80% copper for direct burial in earth or con-
concrete crete
• Fits 1/2", 5/8", and 3/4" ground rods • All bronze non-corrosive copper alloy
• Accommodates wire range from 1/0 to 10 • 4 or 6 solid copper conductor
• All bronze non-corrosive copper alloy and/or • Fits 5/8" copperclad ground rods
stainless steel • Easy installation with field hammer completes
• Stocked for same day shipping secure "compression" connection of rod and
• Saves money by reducing inventory needs conductor
• Designed to withstand a minimum 300 inch • Creates low resistance
pounds of torque

STANDARD DUTY BRONZE CLAMPS


Part # Rod Size Conductor Packaged
(in) Range (per box)
G-5 1/2" & 5/8" 10 SOL - 2 STR 50
G-6 3/4" 10 SOL - 2 STR 50
UGC 1/2", 5/8", 3/4" 10 SOL to 1/0 50
HEAVY DUTY BRONZE CLAMPS
WB58H 5/8" 8 SOL - 1/0 STR 50
WB34H 3/4" 8 SOL - 1/0 STR 50
WB1H 1" 8 SOL - 4/0 STR 50

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 111
Copyright © 2018, American Wire Group, Inc. 20180201
STATIC WIRE/GUY WIRE
GROUNDING CABLES/

NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
TRANSMISSION & DISTRIBUTION CABLES
Table of Contents

DISTRIBUTION CABLES
TRANSMISSION.&
Bare Aluminum Code Name Finder .....................................................................................002
Bare Aluminum Cables
ACSR ..................................................................................................................................401
ACSR/AW ...........................................................................................................................402
ACSS ...................................................................................................................................407
AAC ....................................................................................................................................403
AAAC 6201 Alloy ...............................................................................................................404
ACAR ...................................................................................................................................406
TP Twisted Pair ...................................................................................................................405
ACSR/TW.............................................................................................................................419
ACSS/TW.............................................................................................................................418
Solid Soft-Drawn Tie Wire..................................................................................................408
Covered AL Line Wire Weatherproof.................................................................................409
Packaging Information
ACSR and ACSR/AW ..........................................................................................................410
AAC .....................................................................................................................................411
AAAC 6201 Alloy ...............................................................................................................412
TP Twisted Pair....................................................................................................................413
Covered Line Wire ..............................................................................................................414
Covered Aerial Medium Voltage Cable (Spacer Cable or Tree Wire)
AAC 2 Layer 15kV ...............................................................................................................420
AAC 3 Layer 15kV-35kV ......................................................................................................421
AAC 3 Layer 35kV Electrical Properties ............................................................................426
Spacer Cable Technical Data for 3 Layer Compounds .....................................................427
AAAC 2 Layer 15kV ............................................................................................................422
AAAC 3 Layer 15kV-35kV ...................................................................................................423
ACSR 2 Layer 15kV.............................................................................................................424
ACSR 3 Layer 15kV-35kV....................................................................................................425
Copper Cables
Covered CU Line Wire Weatherproof................................................................................415
Cathodic Protection Cable .................................................................................................416
Transformer Riser Wire (Tap Wire) ....................................................................................417

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 400
Copyright © 2018, American Wire Group, Inc. 20160523
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Bare Aluminum
Code Name Finder

DISTRIBUTION CABLES
TRANSMISSION.&
Code Size Product Catalog Code Size Product Catalog Code Size Product Catalog
Word Type Page Word Type Page Word Type Page
Akron 30.58 AAAC-6201 404 Carnation 1431 AAC 403 Duck/AW 605 ACSR/AW 402
Alliance 246.9 AAAC-6201 404 Catbird/AW 954 ACSR/AW 402 Dunlin TP 715.5 TP-ACSR 405
Alliance TP 246.9 TP-AAAC-6201 405 Cattail 750 AAC 403 Eagle 556.5 ACSR 401
Alton 48.69 AAAC-6201 404 Chickadee 397.5 ACSR 401 Eagle/AW 556.5 ACSR/AW 402
Ames 77.47 AAAC-6201 404 Chickadee TP 397.5 TP-ACSR 405 Egret 636 ACSR 401
Ames TP 77.47 TP-AAAC-6201 405 Chickadee/AW 397.5 ACSR/AW 402 Egret/AW 636 ACSR/AW 402
Amherst 195.7 AAAC-6201 404 Chukar 1780 ACSR 401 Elgin 652.4 AAAC-6201 404
Amherst TP 195.7 TP-AAAC-6201 405 Chukar/AW 1780 ACSR/AW 402 Falcon 1590 ACSR 401
Anaheim 155.4 AAAC-6201 404 Cochin 211.3 ACSR 401 Falcon/AW 1590 ACSR/AW 402
Anaheim TP 155.4 TP-AAAC-6201 405 Cochin/AW 211.3 ACSR/AW 402 Finch 1113 ACSR 401
Arbutus 795 AAC 403 Cockscomb 900 AAC 403 Finch/AW 1113 ACSR/AW 402
Arbutus TP 795 TP-AAC 405 Cockscomb TP 900 TP-AAC 405 Flag 700 AAC 403
Aster 2/0 AAC 403 Columbine 1352 AAC 403 Flamingo 666.6 ACSR 401
Aster TP 2/0 TP-AAC 405 Condor 795 ACSR 401 Flamingo TP 666.6 TP-ACSR 405
Azusa 123.3 AAAC-6201 404 Condor/AW 795 ACSR/AW 402 Flamingo/AW 666.6 ACSR/AW 402
Azusa TP 123.3 TP-AAAC-6201 405 Coot 795 ACSR 401 Flicker 477 ACSR 401
Bersimis/AW 1361 ACSR/AW 402 Coot/AW 795 ACSR/AW 402 Flicker TP 477 TP-ACSR 405
Bittern 1272 ACSR 401 Coreopsis 1590 AAC 403 Flicker/AW 477 ACSR/AW 402
Bittern/AW 1272 ACSR/AW 402 Cosmos 477 AAC 403 Flint 740.8 AAAC-6201 404
Bitterroot 2750 AAC 403 Cosmos TP 477 TP-AAC 405 Flycatcher TP 516.8 TP-AAAC-6201 405
Bluebell 1034 AAC 403 Cowslip 2000 AAC 403 Gannet 666.6 ACSR 401
Bluebell TP 1034 TP-AAC 405 Crane/AW 874.5 ACSR/AW 402 Gannet/AW 666.6 ACSR/AW 402
Bluebird 2156 ACSR 401 Creeper TP 517 TP-AAC 405 Gladiolus 1511 AAC 403
Bluebird/AW 2156 ACSR/AW 402 Crow/AW 715.5 ACSR/AW 402 Gloxinia 12 666.6 TP-AAC 405
Bluebonnet 3500 AAC 403 Cuckoo 795 ACSR 401 Goldenrod 954 AAC 403
Bluejay 1113 ACSR 401 Cuckoo/AW 795 ACSR/AW 402 Goldentuft 450 AAC 403
Bluejay TP 1113 TP-ACSR 405 Curlew 1034 ACSR 401 Goose/AW 636 ACSR/AW 402
Bluejay/AW 1113 ACSR/AW 402 Curlew/AW 1034 ACSR/AW 402 Grackle 1193 ACSR 401
Bobolink 1431 ACSR 401 Daffodil 350 AAC 403 Grackle/AW 1193 ACSR/AW 402
Bobolink/AW 1431 ACSR/AW 402 Dahlia 556.5 AAC 403 Greeley 927.2 AAAC-6201 404
Brahma 203.2 ACSR 401 Dahlia TP 556.5 TP-AAC 405 Grosbeak 636 ACSR 401
Brahma/AW 203.2 ACSR/AW 402 Daisy 266.8 AAC 403 Grosbeak/AW 636 ACSR/AW 402
Brant 397.5 ACSR 401 Daisy TP 266.8 TP-AAC 405 Grouse 80.0 ACSR 401
Brant/AW 397.5 ACSR/AW 402 Darien 559.5 AAAC-6201 404 Guinea 159.0 ACSR 401
Bunting 1193 ACSR 401 Day Lily TP 596 TP-AAAC-6201 405 Guinea/AW 159 ACSR/AW 402
Bunting/AW 1193 ACSR/AW 402 Dipper 1352 ACSR 401 Gull/AW 666.6 ACSR/AW 402
Butte 312.8 AAAC-6201 404 Dipper/AW 1352 ACSR/AW 402 Hawk 477 ACSR 401
Butte TP 312.8 TP-AAAC-6201 405 Dorking 190.8 ACSR 401 Hawk TP 477 TP-ACSR 405
Cairo 465.4 AAAC-6201 404 Dorking/AW 190.8 ACSR/AW 402 Hawk/AW 477 ACSR/AW 402
Camellia 1000 AAC 403 Dotterel 176.9 ACSR 401 Hawkweed 1000 AAC 403
Canary 900 ACSR 401 Dotterel/AW 176.9 ACSR/AW 402 Hawthorn 1193 AAC 403
Canary/AW 900 ACSR/AW 402 Dove 556.5 ACSR 401 Hen 477 ACSR 401
Canna 397.5 AAC 403 Dove TP 556.5 TP-ACSR 405 Hen/AW 477 ACSR/AW 402
Canna TP 397.5 TP-AAC 405 Dove/AW 556.5 ACSR/AW 402 Heron/AW 500 ACSR/AW 402
Canton 394.5 AAAC-6201 404 Drake 795 ACSR 401 Heuchera 650 AAC 403
Cardinal 954 ACSR 401 Drake TP 795 TP-ACSR 405 Hyacinth 500 AAC 403
Cardinal/AW 954 ACSR/AW 402 Drake/AW 795 ACSR/AW 402 Ibis 397.5 ACSR 401
TP is Twisted Pair — Bare Aluminum

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 002
Copyright © 2018, American Wire Group, Inc. 20140110
Bare Aluminum
Code Name Finder
DISTRIBUTION CABLES
TRANSMISSION &

Code Size Product Catalog Code Size Product Catalog Code Size Product Catalog
Word Type Page Word Type Page Word Type Page
Ibis TP 397.5 TP-ACSR 405 Orchid TP 636 TP-AAC 405 Poppy 1/0 AAC 403
Ibis/AW 397.5 ACSR/AW 402 Oriole 336.4 ACSR 401 Poppy TP 1/0 TP-AAC 405
Iris 2 AAC 403 Oriole/AW 336.4 ACSR/AW 402 PtarmiganTP 397.5 TP-ACSR 405
Iris TP 2 TP-AAC 405 Ortolan 1034 ACSR 401 Quail 2/0 ACSR 401
Jaeger TP 228.2 TP-ACSR 405 Ortolan TP 1034 TP-ACSR 405 Quail TP 2/0 TP-ACSR 405
Jessamine 1750 AAC 403 Ortolan/AW 1034 ACSR/AW 402 Quail/AW 2/0 ACSR/AW 402
Joree 2513 ACSR 401 Osprey 556.5 ACSR 401 Rail 954 ACSR 401
Kingbird 636 ACSR 401 Osprey TP 556.5 TP-ACSR 405 Rail/AW 954 ACSR/AW 402
Kingbird TP 636 TP-ACSR 405 Osprey/AW 556.5 ACSR/AW 402 Raven 1/0 ACSR 401
Kingbird/AW 636 ACSR/AW 402 Ostrich 300 ACSR 401 Raven TP 1/0 TP-ACSR 405
Kinglet TP 556.5 TP-ACSR 405 Ostrich/AW 300 ACSR/AW 402 Raven/AW 1/0 ACSR/AW 402
Kittiwake TP 596 TP-ACSR 405 Oxlip 4/0 AAC 403 Redwing 715.5 ACSR 401
Kiwi 2167 ACSR 401 Oxlip TP 4/0 TP-AAC 405 Redwing/AW 715.5 ACSR/AW 402
Kiwi/AW 2167 ACSR/AW 402 Pansy 1 AAC 403 Robin 1 ACSR 401
Lapwing 1590 ACSR 401 Pansy TP 1 TP-AAC 405 Robin TP 1 TP-ACSR 405
Lapwing/AW 1590 ACSR/AW 402 Parakeet 556.5 ACSR 401 Robin/AW 1 ACSR/AW 402
Lark 397.5 ACSR 401 Parakeet TP 556.5 TP-ACSR 405 Rook 636 ACSR 401
Lark/AW 397.5 ACSR/AW 402 Parakeet/AW 556.5 ACSR/AW 402 Rook TP 636 TP-ACSR 405
Larkspur 1034 AAC 403 Parrot 1511 ACSR 401 Rook/AW 636 ACSR/AW 402
Laurel 266.8 AAC 403 Parrot/AW 1511 ACSR/AW 402 Rose 4 AAC 403
Leghorn 134.6 ACSR 401 Partridge 266.8 ACSR 401 Ruddy 900 ACSR 401
Leghorn/AW 134.6 ACSR/AW 402 Partridge TP 266.8 TP-ACSR 405 Ruddy/AW 900 ACSR/AW 402
Lilac 795 AAC 403 Partridge/AW 266.8 ACSR/AW 402 Sagebrush 2250 AAC 403
Lily TP 3 TP-AAC 405 Peachbell 6 AAC 403 Scoter 636 ACSR 401
Linnet 336.4 ACSR 401 Peacock 605 ACSR 401 Scoter/AW 636 ACSR/AW 402
Linnet TP 336.4 TP-ACSR 405 Peacock/AW 605 ACSR/AW 402 Siskin TP 666.6 TP-ACSR 405
Linnet/AW 336.4 ACSR/AW 402 Pelican 477 ACSR 401 Skylark/AW 1272 ACSR/AW 402
Lupine 2500 AAC 403 Pelican TP 477 TP-ACSR 405 Snapdragon 900 AAC 403
Magnolia 954 AAC 403 Pelican/AW 477 ACSR/AW 402 Sneezewort 250 AAC 403
Mallard 795 ACSR 401 Penguin 4/0 ACSR 401 Sparate 2 ACSR 401
Mallard/AW 795 ACSR/AW 402 Penguin TP 4/0 TP-ACSR 405 Sparate/AW 2 ACSR/AW 402
Marigold 1113 AAC 403 Penguin/AW 4/0 ACSR/AW 402 Sparrow 2 ACSR 401
Marigold TP 1114 TP-AAC 405 Peony 300 AAC 403 Sparrow TP 2 TP-ACSR 405
Martin 1352 ACSR 401 Petrel 101.8 ACSR 401 Sparrow/AW 2 ACSR/AW 402
Martin/AW 1352 ACSR/AW 402 Petrel/AW 101.8 ACSR/AW 402 Squab 605 ACSR 401
Meadowsweet 600 AAC 403 Petunia 750 AAC 403 Squab TP 605 TP-ACSR 405
Merlin 336.4 ACSR 401 Pheasant 1272 ACSR 401 Squab/AW 605 ACSR/AW 402
Merlin TP 336.4 TP-ACSR 405 Pheasant/AW 1272 ACSR/AW 402 Starling 715.5 ACSR 401
Merlin/AW 336.4 ACSR/AW 402 Phlox 3/0 AAC 403 Starling/AW 715.5 ACSR/AW 402
Minorca 110.8 ACSR 401 Phlox TP 3/0 TP-AAC 405 Stilt 715.5 ACSR 401
Minorca/AW 110.8 ACSR/AW 402 Phoebe/AW 300 ACSR/AW 402 Stilt/AW 715.5 ACSR/AW 402
Mistletoe 556.5 AAC 403 Pigeon 3/0 ACSR 401 Surfbird TP 874.5 TP-ACSR 405
Narcissus 1272 AAC 403 Pigeon TP 3/0 TP-ACSR 405 Swallow TP 3 TP-ACSR 405
Nasturtium 715.5 AAC 403 Pigeon/AW 3/0 ACSR/AW 402 Swallow/AW 3 ACSR/AW 402
Nuthatch 1511 ACSR 401 Piper/AW 300 ACSR/AW 402 Swan 4 ACSR 401
Nuthatch/AW 1511 ACSR/AW 402 Plover 1431 ACSR 401 Swan/AW 4 ACSR/AW 402
Orchid 636 AAC 403 Plover/AW 1431 ACSR/AW 402 Swanate 4 ACSR 401
TP is Twisted Pair — Bare Aluminum

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
002 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Bare Aluminum
Code Name Finder

DISTRIBUTION CABLES
TRANSMISSION.&
Code Size Product Catalog Code Size Product Catalog Code Size Product Catalog
Word Type Page Word Type Page Word Type Page
Swanate/AW 4 ACSR/AW 402 Tern/AW 795 ACSR/AW 402 Verbena 700 AAC 403
Swift 636 ACSR 401 Thrasher 2312 ACSR 401 Violet TP 715.5 TP-AAC 405
Swift/AW 636 ACSR/AW 402 Thrasher/AW 2312 ACSR/AW 402 Waxwing 266.8 ACSR 401
Syringa 477 AAC 403 Trillium 3000 AAC 403 Waxwing TP 266.8 TP-ACSR 405
Tanager/AW 1034 ACSR/AW 402 Tulip 336.4 AAC 403 Waxwing/AW 266.8 ACSR/AW 402
Tatler TP 477 TP-ACSR 405 Tulip TP 336.4 TP-AAC 405 Wood Duck 605 ACSR 401
Teal 605 ACSR 401 Turacos TP 636 TP-ACSR 405 Wood Duck/AW 605 ACSR/AW 402
Teal/AW 605 ACSR/AW 402 Turkey 6 ACSR 401 Zinnia 500 AAC 403
Tern 795 ACSR 401 Twinstone TP 900 TP-ACSR 405
Tern TP 795 TP-ACSR 405 Valerian 250 AAC 403
TP is Twisted Pair — Bare Aluminum

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 002
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
ACSR

DISTRIBUTION CABLES
TRANSMISSION.&
Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR
offers optimal strength for line design. Variable steel core stranding enables desired strength to be
achieved without sacrificing ampacity.

Construction
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is
available with class A, B, or C galvanizing; “aluminized” aluminum coated (AZ); or aluminum-clad
(AW). Additional corrosion protection is available through the application of grease to the corer or
infusion of the complete cable with grease.

Specifications
ACSR bare conductor meets or exceeds the following ASTM specifications:
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
• B-231 Aluminum Conductors, Concentric-Lay-Stranded
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
• B-502 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
• B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR)
• B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel
Reinforced (ACSR)
Notes
• Resistance is calculated using ASTM standard increments of stranding and metal conductivity of
52.5% IACS, AC resistance at 60Hz.
• Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq.ft
sun, .05 coefficients of emissivity and absorption.

Item # Size Stranding Diameter Diameter Diameter Diameter Weight Weight Weight Rated Allowable Rating
AWG (Al/Stl) Individual Individual Steel Core Complete /MFT /MFT /MFT Breaking Ampacity (amp)
Wire Wire (in) Cable Aluminum Steel Total Strength (amp)
Aluminum Steel O.D. (lb) (lb) (lb) (lb)
(in) (in) (in)
Turkey 6 6/1 0.0661 0.0661 0.0661 0.198 24.5 11.6 36.1 1190 N/A 105
Swan 4 6/1 0.0834 0.0834 0.0834 0.250 39.0 18.4 57.4 1860 N/A 140
Swanate 4 7/1 0.0772 0.1029 0.1029 0.257 39.0 28.0 67 2360 N/A 140
Sparrow 2 6/1 0.1052 0.1052 0.1052 0.316 62.0 29.3 91.3 2850 N/A 184
Sparate 2 7/1 0.0974 0.1299 0.1299 0.325 62.0 44.7 106.7 3640 N/A 184
Robin 1 6/1 0.1181 0.1181 0.1181 0.354 78.2 36.9 115.1 3550 N/A 212
Raven 1/0 6/1 0.1327 0.1327 0.1327 0.398 98.7 46.6 145.3 4380 N/A 242
Quail 2/0 6/1 0.1489 0.1489 0.1489 0.447 124.3 58.7 183 5300 N/A 276
Pigeon 3/0 6/1 0.1672 0.1672 0.1672 0.502 156.7 74.0 230.7 6620 N/A 315
Penguin 4/0 6/1 0.1878 0.1878 0.1878 0.563 197.7 93.4 291.1 8350 N/A 357
Waxwing 266.8 18/1 0.1217 0.1217 0.1217 0.609 250.3 39.2 289.5 6880 N/A 449
Partridge 266.8 26/7 0.1013 0.0788 0.2364 0.642 251.7 115.6 367.2 11300 N/A 475
Ostrich 300.0 26/7 0.1074 0.0835 0.2505 0.680 282.9 129.8 412.7 12700 N/A 492
Merlin 336.4 18/1 0.1367 0.1367 0.1367 0.683 315.8 49.5 365.2 8680 N/A 519
Linnet 336.4 26/7 0.1137 0.0884 0.2642 0.720 317.1 145.4 462.5 14100 N/A 529
Oriole 336.4 30/7 0.1059 0.1059 0.3117 0.741 318.2 208.9 527.1 17800 N/A 535
Chickadee 397.5 18/1 0.1486 0.1486 0.1486 0.743 373.1 58.5 431.6 9940 N/A 576
Brant 397.5 24/7 0.1287 0.0858 0.2574 0.772 375.0 137.0 512 14500 N/A 584
Ibis 397.5 26/7 0.1236 0.0961 0.2882 0.783 374.7 171.9 546.6 16300 N/A 587
Lark 397.5 30/7 0.1151 0.1151 0.3453 0.806 375.8 246.8 622.6 20300 N/A 594
Pelican 477.0 18/1 0.1628 0.1628 0.1628 0.814 447.8 70.2 518 11800 N/A 646
Flicker 477.0 24/7 0.1410 0.0940 0.2820 0.846 450.1 164.4 614.5 17200 N/A 655

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 401
Copyright © 2018, American Wire Group, Inc. 20160520
ACSR
DISTRIBUTION CABLES
TRANSMISSION &

Item # Size Stranding Diameter Diameter Diameter Diameter Weight Weight Weight Rated Allowable Rating
AWG (Al/Stl) Individual Individual Steel Core Complete /MFT /MFT /MFT Breaking Ampacity (amp)
Wire Wire (in) Cable Aluminum Steel Total Strength (amp)
Aluminum Steel (O.D.) (lb) (lb) (lb) (lb)
(in) (in) (in)
Hawk 477.0 26/7 0.1354 0.1053 0.3159 0.858 449.6 206.4 656 19500 N/A 659
Hen 477.0 30/7 0.1261 0.1261 0.3783 0.883 451.1 296.2 747.3 23800 N/A 666
Osprey 556.5 18/1 0.1758 0.1758 0.1758 0.879 522.2 81.8 604.1 13700 N/A 711
Parakeet 556.5 24/7 0.1523 0.1015 0.3045 0.914 525.1 191.7 716.9 19800 N/A 721
Dove 556.5 26/7 0.1463 0.1138 0.3414 0.927 525.0 241.0 766 22500 N/A 726
Eagle 556.5 30/7 0.1362 0.1362 0.4086 0.953 526.3 345.6 871.8 27800 N/A 734
Peacock 605.0 24/7 0.1588 0.1059 0.3177 0.953 570.9 208.7 779.6 21600 N/A 760
Squab 605.0 26/7 0.1525 0.1186 0.3558 0.966 570.4 261.8 832.2 24300 N/A 765
Wood Duck 605.0 30/7 0.1420 0.1420 0.4260 0.994 572.0 375.6 947.7 28900 N/A 774
Teal 605.0 30/19 0.1420 0.0852 0.4260 0.994 572.0 367.4 939.4 30000 N/A 773
Kingbird 636.0 18/1 0.1880 0.1880 0.1880 0.940 597.2 93.6 690.8 15700 N/A 773
Swift 636.0 36/1 0.1329 0.1329 0.1329 0.930 596.9 46.8 643.7 13800 N/A 769
Rook 636.0 24/7 0.1628 0.1085 0.3255 0.977 600.0 219.1 819.1 22600 N/A 784
Grosbeak 636.0 26/7 0.1564 0.1216 0.3648 0.990 597.9 276.2 874.1 25200 N/A 789
Scoter 636.0 30/7 0.1456 0.1456 0.4368 1.019 601.4 394.9 996.3 30400 N/A 798
Egret 636.0 30/19 0.1456 0.0874 0.4370 1.019 601.4 386.6 988 31500 N/A 798
Flamingo 666.6 24/7 0.1667 0.1110 0.3330 1.000 629.1 229.7 858.8 23700 N/A 807
Gannet 666.6 26/7 0.1601 0.1245 0.3730 1.014 628.7 288.5 917.1 26400 N/A 812
Stilt 715.5 24/7 0.1727 0.1151 0.3453 1.036 675.2 246.5 921.8 25500 N/A 844
Starling 715.5 26/7 0.1659 0.1290 0.3870 1.051 675.0 309.7 984.7 28400 N/A 849
Redwing 715.5 30/19 0.1544 0.0926 0.4630 1.081 676.3 434.0 1110 34600 N/A 859
Coot 795.0 36/1 0.1486 0.1486 0.1486 1.040 746.2 58.5 804.7 16800 N/A 884
Cuckoo 795.0 24/7 0.1820 0.1213 0.3640 1.092 749.9 273.8 1024 27900 N/A 901
Drake 795.0 26/7 0.1749 0.1360 0.4080 1.108 750.3 344.2 1094 31500 N/A 907
Tern 795.0 45/7 0.1329 0.0886 0.2548 1.063 749.8 146.1 895.9 22100 N/A 887
Condor 795.0 54/7 0.1213 0.1213 0.3639 1.092 749.5 273.6 1023 28200 N/A 889
Mallard 795.0 30/19 0.1628 0.0977 0.4885 1.140 751.9 483.1 1235 38400 N/A 918
Ruddy 900.0 45/7 0.1414 0.0943 0.2829 1.131 848.7 165.5 1014 24400 N/A 958
Canary 900.0 54/7 0.1291 0.1291 0.3873 1.162 849.0 309.9 1149 31900 N/A 961
Rail 954.0 45/7 0.1456 0.0971 0.2913 1.165 899.9 175.5 1075 25900 N/A 993
Cardinal 954.0 54/7 0.1329 0.1329 0.3987 1.196 900.7 328.4 1228 33800 N/A 996
Ortolan 1033.5 45/7 0.1515 0.1010 0.3030 1.212 974.3 189.8 1164 27700 N/A 1043
Curlew 1033.5 54/7 0.1383 0.1383 0.4149 1.245 974.3 355.6 1330 36600 N/A 1047
Bluejay 1113.0 45/7 0.1573 0.1049 0.3147 1.259 1050.0 204.8 1255 29800 N/A 1092
Finch 1113.0 54/19 0.1436 0.0862 0.4310 1.293 1056.0 276.1 1432 39100 N/A 1093
Bunting 1192.5 45/7 0.1628 0.1085 0.3255 1.302 1125.0 219.1 1344 32000 N/A 1139
Grackle 1192.5 54/19 0.1486 0.0892 0.4460 1.338 1130.0 402.7 1533 41900 N/A 1140
Bittern 1272.0 45/7 0.1681 0.1121 0.3363 1.345 1200.0 233.9 1433 34100 N/A 1184
Pheasant 1272.0 54/19 0.1535 0.0921 0.4605 1.382 1206.0 429.3 1635 43500 N/A 1187
Dipper 1351.5 45/7 0.1733 0.1155 0.3465 1.386 1275.0 248.3 1525 36200 N/A 1229
Martin 1351.5 54/19 0.1582 0.9049 0.4745 1.424 1281.0 455.8 1737 46300 N/A 1232
Bobolink 1431.0 45/7 0.1783 0.1189 0.3567 1.427 1350.0 263.1 1613 38300 N/A 1272
Plover 1431.0 54/19 0.1628 0.0977 0.4885 1.465 1357.0 483.1 1840 49100 N/A 1275
Nuthatch 1510.5 45/7 0.1832 0.1221 0.3663 1.465 1425.0 277.4 1702 40100 N/A 1313
Parrot 1510.5 54/19 0.1672 0.1003 0.5015 1.505 1431.0 509.2 1940 51700 N/A 1318

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
401 Information on this sheet subject to change without notice.
20150520 Copyright © 2018, American Wire Group, Inc.
ACSR

DISTRIBUTION CABLES
TRANSMISSION.&
Item # Size Stranding Diameter Diameter Diameter Diameter Weight Weight Weight Rated Allowable Rating
AWG (Al/Stl) Individual Individual Steel Core Complete /MFT /MFT /MFT Breaking Ampacity (amp)
Wire Wire (in) Cable Aluminum Steel Total Strength (amp)
Aluminum Steel O.D. (lb) (lb) (lb) (lb)
(in) (in) (in)
Lapwing 1590.0 45/7 0.1880 0.1253 0.3759 1.504 1498.0 292.2 1793 42200 N/A 1354
Falcon 1590.0 54/19 0.1716 0.1030 0.5150 1.545 1507.0 537.0 2044 54500 N/A 1359
Chukar 1780.0 84/19 0.1456 0.0874 0.4370 1.602 1688.0 386.6 2975 51000 N/A 1453
Bluebird 2156.0 84/19 0.1602 0.0961 0.4805 1.762 2044.0 467.4 2511 60300 N/A 1623
Kiwi 2167.0 72/7 0.1735 0.1157 0.3471 1.735 2055.0 248.9 2303 49800 N/A 1607
Thrasher 2312.0 76/19 0.1744 0.0814 0.4070 1.802 2191.0 335.4 2527 56700 N/A 1673
Joree 2515.0 76/19 0.1819 0.0849 0.4245 1.880 2384.0 364.8 2749 61700 N/A 1751
High Mechanical Strength
Grouse 80.0 8/1 0.1000 0.1670 0.1670 0.367 75.1 73.9 149 5200 204 N/A
Petrel 101.8 12/7 0.0921 0.0921 0.2763 0.461 96.0 158.0 254 10400 237 N/A
Minorca 110.8 12/7 0.0961 0.0961 0.2883 0.481 104.5 172.1 276 11300 246 N/A
Leghorn 134.6 12/7 0.1059 0.1059 0.3177 0.530 127.0 208.9 336 13600 273 N/A
Guinea 159.0 12/7 0.1151 0.1151 0.3453 0.576 150.0 246.8 396 16000 297 N/A
Dotterel 176.9 12/7 0.1214 0.1214 0.3642 0.607 166.9 274.6 441 17300 312 N/A
Dorking 190.8 12/7 0.1261 0.1261 0.3783 0.631 180.0 296.3 476 18700 324 N/A
Brahma 203.2 16/19 0.1227 0.0977 0.4885 0.714 191.7 485.0 675 28400 341 N/A
Cochin 211.3 12/7 0.1327 0.1327 0.3981 0.664 199.3 328.2 527 20700 340 N/A

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 401
Copyright © 2018, American Wire Group, Inc. 20150520
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
ACSR/AW

DISTRIBUTION CABLES
TRANSMISSION.&
Applications
ACSR/AW cables are used for overhead transmission and distribution lines. Also, as neutral mes-
senger for low voltage multiplex cables.

Construction
Aluminum 1350 H-19 wires, concentrically stranded about an aluminum-clad steel core wire (AW).

Specifications
• ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
• ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded
• ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
• ASTM B-502 Aluminum-Clad Steel Core Wire for Aluminum Conductors, Aluminum-Clad Steel
Reinforced
• ASTM B-549 Aluminum Conductors Concentric-Lay-Stranded, Aluminum-Clad Steel Reinforced
(ACSR/AW)

Item # Size Stranding Diameter Diameter Diameter Diameter Weight Weight Weight Resistance Allowable Rating*
AWG (Al/Stl) Individual Individual Steel Core Complete /MFT /MFT /MFT /MFT Ampacity* (amp)
Wire Wire (in) Cable Aluminum AW Total DC 20°C (amp)
Aluminum Steel O.D. (lb) (lb) (lb) (ohm)
(in) (in) (in)
Petrel/AW 101.8 12/7 0.0921 0.0921 0.2763 0.4610 133.70 96.10 229.80 0.143 281 N/A
Minorca/AW 110.8 12/7 0.0961 0.0961 0.2883 0.4810 145.60 104.60 250.30 0.131 297 N/A
Leghorn/AW 134.6 12/7 0.1059 0.1059 0.3177 0.5300 176.90 127.10 303.90 0.108 335 N/A
Guinea/AW 159 12/7 0.1151 0.1151 0.3453 0.5760 209.00 150.10 359.10 0.091 372 N/A
Dotterel/AW 176.9 12/7 0.1214 0.1214 0.3642 0.6070 232.50 167.00 399.50 0.082 398 N/A
Dorking/AW 190.8 12/7 0.1261 0.1261 0.3783 0.6310 250.80 180.10 430.90 0.076 418 N/A
Brahma/AW 203.2 16/19 0.1227 0.0977 0.4885 0.7140 409.50 191.90 601.40 0.066 464 N/A
Cochin/AW 211.3 12/7 0.1327 0.1327 0.3981 0.6640 277.60 199.40 477.00 0.069 445 N/A
Swan/AW 4 6/1 0.0834 0.0834 0.0834 0.2500 39.00 15.60 54.60 0.390 N/A 145
Swanate/AW 4 7/1 0.0772 0.1029 0.1029 0.2570 39.00 23.70 62.70 0.380 N/A 148
Swallow/AW 3 6/1 0.0937 0.0937 0.0094 0.0281 49.30 19.70 68.90 0.309 N/A N/A
Sparrow/AW 2 6/1 0.1052 0.1052 0.1052 0.3160 62.10 24.80 86.90 0.245 N/A 194
Sparate/AW 2 7/1 0.0974 0.1299 0.1295 0.3240 62.10 37.70 99.70 0.239 N/A 198
Robin/AW 1 6/1 0.1181 0.1181 0.1181 0.3540 78.30 31.30 109.50 0.195 N/A 225
Raven/AW 1/0 6/1 0.1327 0.1327 0.1327 0.3980 98.80 39.50 138.30 0.154 N/A 260
Quail/AW 2/0 6/1 0.1489 0.1489 0.1489 0.4470 124.40 49.80 174.10 0.122 N/A 301
Pigeon/AW 3/0 6/1 0.1672 0.1672 0.1672 0.5020 156.80 62.70 220.00 0.097 N/A 347
Penguin/AW 4/0 6/1 0.1878 0.1878 0.1878 0.5630 197.80 79.10 276.90 0.077 N/A 402
Waxwing/AW 266.8 18/1 0.1217 0.1217 0.1217 0.6080 250.40 33.20 283.60 0.064 N/A 451
Partridge/AW 266.8 26/7 0.1013 0.0788 0.2364 0.6420 251.90 98.00 349.80 0.062 N/A 465
Phoebe/AW 300 18/1 0.1291 0.1291 0.1291 0.6460 282.00 37.40 319.40 0.057 N/A N/A
Ostrich/AW 300 26/7 0.1074 0.0835 0.2505 0.6800 283.10 110.00 393.10 0.055 N/A 500
Piper/AW 300 30/7 0.1000 0.1000 0.3000 0.7000 283.90 157.70 441.60 0.054 N/A N/A
Merlin/AW 336.4 18/1 0.1367 0.1367 0.1367 0.6830 316.00 41.90 357.90 0.050 N/A 522
Linnet/AW 336.4 26/7 0.1137 0.0884 0.2642 0.7200 317.30 123.20 440.50 0.049 N/A 537
Oriole/AW 336.4 30/7 0.1059 0.1059 0.3117 0.7410 318.40 176.90 495.30 0.048 N/A 547
*Please contact AWG where Ampacity/Rating is N/A.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 402
Copyright © 2018, American Wire Group, Inc. 20150601
ACSR/AW
DISTRIBUTION CABLES
TRANSMISSION &

Item # Size Stranding Diameter Diameter Diameter Diameter Weight Weight Weight Resistance Allowable Rating*
AWG (Al/Stl) Individual Individual Steel Core Complete /MFT /MFT /MFT /MFT Ampacity* (amp)
Wire Wire (in) Cable Aluminum AW Total DC 20°C (amp)
Aluminum Steel O.D. (lb) (lb) (lb) (ohm)
(in) (in) (in)
Chickadee/AW 397.5 18/1 0.1486 0.1486 0.1486 0.7430 373.30 49.50 422.90 0.043 N/A 580
Brant/AW 397.5 24/7 0.1287 0.0858 0.2574 0.7720 375.30 116.10 491.30 0.042 N/A 592
Ibis/AW 397.5 26/7 0.1236 0.0961 0.2882 0.7830 374.90 145.60 520.50 0.041 N/A 597
Lark/AW 397.5 30/7 0.1151 0.1151 0.3453 0.8060 376.20 209.00 585.20 0.041 N/A 608
Pelican/AW 477 18/1 0.1628 0.1628 0.1628 0.8140 448.10 59.50 507.60 0.036 N/A 651
Flicker/AW 477 24/7 0.1410 0.0940 0.2820 0.8460 450.30 139.39 589.70 0.035 N/A 663
Hawk/AW 477 26/7 0.1354 0.1053 0.3159 0.8580 449.90 174.90 624.80 0.035 N/A 669
Hen/AW 477 30/7 0.1261 0.1261 0.3783 0.8830 451.50 250.76 702.20 0.034 N/A 682
Heron/AW 500 30/7 0.1291 0.1291 0.3870 0.9040 473.40 262.96 736.40 0.032 N/A N/A
Osprey/AW 556.5 18/1 0.1758 0.1758 0.1758 0.8790 522.50 69.34 591.90 0.031 N/A 715
Parakeet/AW 556.5 24/7 0.1523 0.1015 0.3045 0.9140 525.40 162.45 687.90 0.030 N/A 731
Dove/AW 556.5 26/7 0.1463 0.1138 0.3414 0.9270 525.30 204.29 729.60 0.030 N/A 737
Eagle/AW 556.5 30/7 0.1362 0.1362 0.4086 0.9530 526.50 292.45 819.00 0.029 N/A 751
Peacock/AW 605 24/7 0.1588 0.1059 0.3177 0.9530 571.50 176.87 748.40 0.027 N/A 770
Squab/AW 605 26/7 0.1525 0.1186 0.3558 0.9660 571.00 221.75 792.70 0.027 N/A 777
WoodDuck/AW 605 30/7 0.1420 0.1420 0.4260 0.9940 572.50 318.01 890.50 0.027 N/A N/A
Teal/AW 605 30/19 0.1420 0.0852 0.4260 0.9940 572.50 311.30 883.80 0.027 N/A 791
Duck/AW 605 54/7 0.1059 0.1059 0.3180 0.9530 571.80 176.87 748.60 0.027 N/A N/A
Kingbird/AW 636 18/1 0.1880 0.1880 0.1880 0.9400 597.60 79.46 677.10 0.027 N/A 778
Rook/AW 636 24/7 0.1628 0.1085 0.3255 0.9770 600.50 185.66 786.10 0.026 N/A 794
Grosbeak/AW 636 26/7 0.1564 0.1216 0.3648 0.9900 600.50 233.23 833.80 0.026 N/A 801
Scoter/AW 636 30/7 0.1456 0.1456 0.4368 1.0190 601.80 334.26 936.00 0.025 N/A N/A
Egret/AW 636 30/19 0.1456 0.0874 0.4370 1.0190 601.80 327.62 929.40 0.025 N/A N/A
Swift/AW 636 24/7 0.1329 0.1329 0.1329 0.9300 597.50 39.64 637.10 0.027 N/A N/A
Goose/AW 636 26/7 0.1085 0.1087 0.3260 0.9770 600.20 186.19 786.40 0.026 N/A N/A
Flamingo/AW 666.6 24/7 0.1667 0.1110 0.3330 1.3330 629.30 194.65 823.90 0.025 N/A 818
Gannet/AW 666.6 26/7 0.1601 0.1245 0.3730 1.0140 629.30 244.38 873.70 0.025 N/A 825
Gull/AW 666.6 54/7 0.1110 0.1110 0.3330 0.9990 628.40 194.38 822.70 0.025 N/A N/A
Stilt/AW 715.5 24/7 0.1727 0.1151 0.3453 1.0360 675.60 208.98 884.60 0.023 N/A N/A
Starling/AW 715.5 26/7 0.1659 0.1290 0.3870 1.0510 675.60 262.48 938.10 0.023 N/A 863
Redwing/AW 715.5 30/19 0.1544 0.0926 0.4630 1.0810 676.90 367.74 1044.60 0.023 N/A 878
Crow/AW 715.5 54.7 0.1150 0.1150 0.3450 1.0350 673.70 208.41 882.10 0.023 N/A N/A
Coot/AW 795 36/1 0.1486 0.1486 0.1486 1.0400 750.60 232.02 982.60 0.021 N/A N/A
Cuckoo/AW 795 24/7 0.1820 0.1213 0.3640 1.0920 750.70 232.00 982.70 0.021 N/A 913
Drake/AW 795 26/7 0.1749 0.1360 0.4080 1.1070 748.00 292.00 1040.00 0.022 N/A 922
Tern/AW 795 45/7 0.1329 0.0886 0.2660 1.0630 750.50 123.74 874.20 0.021 N/A 896
Condor/AW 795 54/7 0.1213 0.1213 0.3639 1.0920 750.10 232.02 982.10 0.021 N/A 913
Mallard/AW 795 30/19 0.1628 0.0977 0.4885 1.1400 752.40 409.52 1161.90 0.020 N/A 938
Crane/AW 874.5 54/7 0.1272 0.1272 0.3810 1.4440 824.40 255.01 1079.40 0.019 N/A N/A
Ruddy/AW 900 45/7 0.1414 0.0943 0.2829 1.1310 849.60 140.20 989.80 0.019 N/A 970
Canary/AW 900 54/7 0.1291 0.1291 0.3873 1.1620 849.60 262.80 1112.40 0.018 N/A 986
Catbird/AW 954 36/1 0.1628 0.1628 0.1628 1.1400 896.30 59.47 955.80 0.018 N/A N/A
Rail/AW 954 45/7 0.1456 0.0971 0.2913 1.1650 900.50 148.64 1049.10 0.018 N/A 1003
Cardinal/AW 954 54/7 0.1329 0.1329 0.3987 1.1960 900.60 278.58 1179.20 0.017 N/A 1022
Tanager/AW 1033.5 36/1 0.1694 0.1694 0.1694 1.1860 970.60 64.40 1035.00 0.017 N/A N/A
*Please contact AWG where Ampacity/Rating is N/A.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
402 Information on this sheet subject to change without notice.
20150601 Copyright © 2018, American Wire Group, Inc.
ACSR/AW

DISTRIBUTION CABLES
TRANSMISSION.&
Item # Size Stranding Diameter Diameter Diameter Diameter Weight Weight Weight Resistance Allowable Rating*
AWG (Al/Stl) Individual Individual Steel Core Complete /MFT /MFT /MFT /MFT Ampacity* (amp)
Wire Wire (in) Cable Aluminum AW Total DC 20°C (amp)
Aluminum Steel O.D. (lb) (lb) (lb) (ohm)
(in) (in) (in)
Ortolan/AW 1033.5 45/7 0.1515 0.1010 0.3030 1.2120 975.00 160.81 1135.80 0.016 N/A 1054
Curlew/AW 1033.5 54/7 0.1383 0.1383 0.4149 1.2450 975.20 301.65 1276.80 0.016 N/A 1074
Bluejay/AW 1113 45/7 0.1573 0.1049 0.3147 1.2580 1051.00 173.47 1224.40 0.015 N/A 1103
Finch/AW 1113 54/19 0.1436 0.0862 0.4310 1.2910 1056.00 318.54 1374.60 0.015 N/A N/A
Bunting/AW 1192.5 45/7 0.1628 0.1085 0.3255 1.3020 1126.00 185.66 1311.50 0.014 N/A N/A
Grackle/AW 1192.5 54/19 0.1486 0.0892 0.4460 1.3380 1131.00 341.34 1472.30 0.014 N/A N/A
Skylark/AW 1272 36/1 0.1880 0.1880 0.1880 1.3160 1195.00 79.30 1274.50 0.013 N/A N/A
Bittern/AW 1272 45/7 0.1681 0.1121 0.3363 1.3450 1201.00 198.12 1398.70 0.013 N/A N/A
Pheasant/AW 1272 54/19 0.1535 0.0921 0.4605 1.3810 1207.00 363.69 1570.80 0.013 N/A 1216
Dipper/AW 1351.5 45/7 0.1733 0.1155 0.3465 1.3860 1276.00 210.41 1486.40 0.013 N/A N/A
Martin/AW 1351.5 54/19 0.1582 0.9490 0.4745 1.4240 1282.00 386.10 1668.00 0.012 N/A N/A
Bersimis/AW 1361 42/7 0.1799 0.1000 0.3000 1.3800 1284.00 157.69 1441.20 0.013 N/A N/A
Bobolink/AW 1431 45/7 0.1783 0.1189 0.3567 1.4270 1351.00 222.93 1573.60 0.012 N/A 1283
Plover/AW 1431 54/19 0.1628 0.0977 0.4885 1.4650 1358.00 409.52 1767.10 0.012 N/A N/A
Nuthatch/AW 1510.5 45/7 0.1832 0.1221 0.3663 1.4650 1426.00 235.05 1660.70 0.011 N/A N/A
Parrot/AW 1510.5 54/19 0.1672 0.1003 0.5015 1.5050 1432.00 431.59 1863.80 0.011 N/A N/A
Lapwing/AW 1590 45/7 0.1880 0.1253 0.3759 1.5040 1501.00 247.64 1749.00 0.011 N/A 1365
Falcon/AW 1590 54/19 0.1716 0.1030 0.5150 1.5450 1509.00 454.93 1963.60 0.011 N/A N/A
Chukar/AW 1780 84/19 0.1456 0.0874 0.4370 1.6020 1691.00 327.62 2018.50 0.010 N/A N/A
Bluebird/AW 2156 84/19 0.1602 0.0961 0.4805 1.7620 2045.00 396.10 2441.10 0.008 N/A N/A
Kiwi/AW 2167 72/7 0.1735 0.1157 0.3471 1.7350 2056.00 211.13 2267.30 0.008 N/A N/A
Thrasher/AW 2312 76/19 0.1744 0.0814 0.4070 1.8020 2193.00 284.30 2477.40 0.007 N/A N/A
*Please contact AWG where Ampacity/Rating is N/A.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 402
Copyright © 2018, American Wire Group, Inc. 20150601
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
ACSS

DISTRIBUTION CABLES
TRANSMISSION.&
Applications
Used for overhead distribution and transmission lines. Designed to operate continuously at ele-
vated temperatures up to 250°C without loss of strength. It sags less under emergency electrical
loadings than ASCR; it is self-damping if prestretched during installation, and the final sags are not
affected by long term creep of aluminum. The advantages make ACSS especially useful in recon-
ductoring applications requiring increased current with existing tensions and clearances, new line
applications where structures can be economized because of reduced conductor sag, new line ap-
plications requiring high emergency loadings, and lines where aeolian vibration is a problem.

Construction
ACSS is a composite concentric-lay stranded conductor. Steel strands form the central core of the
conductor with one or more layers of aluminum 1350-0 wire stranded around it. The steel core car-
ries most or all of the mechanical load of the conductor due to the (fully annealed or soft) temper
aluminum. Steel core wires are protected from corrosion by galvanizing, aluminizing, or mischmetal
alloy coating. Corrosion protection should be selected to suit the environment to which the conduc-
tor will be exposed. High strength steel core is also available.

Standards
ACSS conductor meets or exceeds the following ASTM specifications:
• B500 Metallic Coated Stranded Steel Core for Use in Overhead Electrical Conductors.
• B609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers for Electrical Purposes.
• B802 Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Aluminum Conductors,
Steel Reinforced (ACSR).
• B803 High-Strength Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Use in Over-
head Electrical Conductors.
• B856 Concentric-Lay-Stranded Aluminum Conductors, Coated Steel Supported (ACSS).
• B958 Extra-High-Strength and Ultra-High-Strength Class A Zinc-5% Aluminum-Mischmetal Alloy-
Coated Steel Core
Wire for Use in Overhead Electrical Conductors.
Options
• Regular-Strength Class C galvanized steel core
• High-Strength Class A galvanized steel core
• Extra-High-Strength Class A galvanized steel core
• Ultra-High-Strength Class A galvanized steel core
• Regular-Strength Class A zinc-5% aluminum misch-metal alloy-coated steel core
• High-Strength Class A zinc-5% aluminum misch-metal alloy-coated steel core
• Extra-High-Strength Class A zinc-5% aluminum misch-metal alloy-coated steel core
• Ultra-High-Strength Class A zinc-5% aluminum misch-metal alloy-coated steel core
• Aluminum-clad steel core
• 250°C Operating Temperature rating utilizing either the zinc-5% aluminum mischmetal alloy-
coated steel core wires, or the aluminum-clad steel core wires.
• Non-specular surface finish

Item # Size Stranding Dia. Dia. Dia. Dia. Weight Weight Weight Rated Resist. Resist. Ampacity
AWG Al/St Ind. Ind. Steel Complete /MFT /MFT /MFT Strength DC@20°C AC@75°C
or Wire Wire Core Cable Aluminum Steel Total (lb) /MFT /MFT
KCMIL (in) (in) (in) (in) (lb) (lb) (lb) (ohm) (ohm)
Partridge ACSS 266.8 26 / 7 0.1013 0.0788 0.2364 0.642 251.3 115.6 366.9 8,880 0.0619 0.0761 812
Junco ACSS 266.8 30 / 7 0.0943 0.0943 0.2829 0.660 251.3 165.5 416.8 11,700 0.0615 0.0756 822
Ostrich ACSS 300.0 26 / 7 0.1074 0.0835 0.2505 0.680 282.5 129.8 412.3 10,000 0.0551 0.0677 877
Woodcock ACSS 336.4 22 / 7 0.1237 0.0687 0.2061 0.701 317.1 84.8 401.9 7,610 0.0495 0.0609 933
Linnet ACSS 336.4 26 / 7 0.1137 0.0884 0.2652 0.720 316.6 145.5 462.1 11,200 0.0491 0.0604 945
Oriole ACSS 336.4 30 / 7 0.1059 0.1059 0.3177 0.741 317.7 208.7 526.4 14,800 0.0488 0.0600 957
Ptarmigan ACSS 397.5 20 / 7 0.1410 0.0627 0.1881 0.752 374.5 73.2 447.7 7,090 0.0421 0.0518 1034
Brant ACSS 397.5 24 / 7 0.1287 0.0858 0.2574 0.772 374.4 137.0 511.4 11,000 0.0417 0.0514 1047
Ibis ACSS 397.5 26 / 7 0.1236 0.0961 0.2883 0.783 374.1 171.9 546.0 13,000 0.0416 0.0512 1054
Lark ACSS 397.5 30 / 7 0.1151 0.1151 0.3453 0.806 375.3 246.6 621.9 17,500 0.0413 0.0508 1068

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 407
Copyright © 2018, American Wire Group, Inc. 20140925
ACSS
DISTRIBUTION CABLES
TRANSMISSION &

Item # Size Stranding Dia. Dia. Dia. Dia. Weight Weight Weight Rated Resist. Resist. Ampacity
AWG Al/St Ind. Ind. Steel Complete /MFT /MFT /MFT Strength DC@20°C AC@75°C
or Wire Wire Core Cable Aluminum Steel Total (lb) /MFT /MFT
KCMIL (in) (in) (in) (in) (lb) (lb) (lb) (ohm) (ohm)
Tailorbird ACSS 477.0 20 / 7 0.1544 0.0686 0.2058 0.823 449.1 87.6 536.7 8,490 0.0351 0.0433 1165
Flicker ACSS 477.0 24 / 7 0.1410 0.0940 0.2820 0.846 449.4 164.5 613.9 13,000 0.0348 0.0429 1180
Hawk ACSS 477.0 26 / 7 0.1354 0.1053 0.3159 0.858 449.0 206.4 655.4 15,600 0.0346 0.0427 1188
Hen ACSS 477.0 30 / 7 0.1261 0.1261 0.3783 0.883 450.4 296.0 746.4 21,000 0.0344 0.0424 1204
Sapsucker ACSS 556.5 22 / 7 0.1590 0.0883 0.2649 0.901 523.9 145.1 669.0 12,600 0.0299 0.0370 1297
Parakeet ACSS 556.5 24 / 7 0.1523 0.1015 0.3045 0.914 524.3 191.8 716.1 15,200 0.0298 0.0368 1306
Dove ACSS 556.5 26 / 7 0.1463 0.1138 0.3414 0.927 524.2 241.0 765.2 18,200 0.0297 0.0366 1315
Eagle ACSS 556.5 30 / 7 0.1362 0.1362 0.4068 0.953 525.5 345.3 870.8 24,500 0.0295 0.0363 1331
Peacock ACSS 605.0 24 / 7 0.1588 0.1059 0.3177 0.953 570.0 208.7 778.7 16,500 0.0274 0.0339 1379
Squab ACSS 605.0 26 / 7 0.1525 0.1186 0.3558 0.966 569.5 261.8 831.3 19,700 0.0273 0.0337 1389
Wood Duck ACSS 605.0 30 / 7 0.1420 0.1420 0.4260 0.994 571.2 375.3 946.5 26,100 0.0271 0.0334 1407
Teal ACSS 605.0 30 / 19 0.1420 0.0852 0.4260 0.994 571.2 367.5 938.7 26,600 0.0272 0.0335 1406
Goldfinch ACSS 636.0 22 / 7 0.1700 0.0944 0.2832 0.963 598.9 165.9 764.8 14,100 0.0262 0.0324 1415
Rook ACSS 636.0 24 / 7 0.1628 0.1085 0.3255 0.977 599.1 219.1 818.2 17,300 0.0261 0.0322 1425
Grosbeak ACSS 636.0 26 / 7 0.1564 0.1216 0.3648 0.990 599.0 275.2 874.2 20,700 0.0260 0.0321 1435
Scoter ACSS 636.0 30 / 7 0.1456 0.1456 0.4368 1.019 600.5 394.6 995.1 27,400 0.0258 0.0318 1454
Egret ACSS 636.0 30 / 19 0.1456 0.0874 0.4370 1.019 600.5 386.7 987.2 28,000 0.0258 0.0319 1453
Flamingo ACSS 666.6 24 / 7 0.1667 0.1111 0.3333 1.000 628.2 229.7 857.9 18,200 0.0249 0.0308 1470
Gannet ACSS 666.6 26 / 7 0.1601 0.1245 0.3735 1.014 627.7 288.5 916.2 21,700 0.0248 0.0306 1480
Stilt ACSS 715.5 24 / 7 0.1727 0.1151 0.3453 1.036 674.2 246.6 920.8 19,500 0.0232 0.0287 1540
Starling ACSS 715.5 26 / 7 0.1659 0.1290 0.3870 1.051 674.0 309.7 983.7 23,300 0.0231 0.0286 1550
Redwing ACSS 715.5 30 / 19 0.1544 0.0926 0.4630 1.081 675.3 434.1 1109.4 30,800 0.0230 0.0284 1570
Cuckoo ACSS 795.0 24 / 7 0.1820 0.1213 0.3639 1.092 748.8 273.9 1022.7 21,700 0.0209 0.0259 1650
Drake ACSS 795.0 26 / 7 0.1749 0.1360 0.4080 1.108 749.1 344.3 1093.4 25,900 0.0209 0.0257 1662
Macaw ACSS 795.0 42 / 7 0.1376 0.0764 0.2292 1.055 749.0 108.6 857.6 11,800 0.0211 0.0262 1621
Tern ACSS 795.0 45 / 7 0.1329 0.0886 0.2658 1.063 748.6 146.1 894.7 14,200 0.0210 0.0263 1618
Condor ACSS 795.0 54 / 7 0.1213 0.1213 0.3639 1.092 748.4 273.9 1022.3 16,600 0.0209 0.0026 1618
Mallard ACSS 795.0 30 / 19 0.0628 0.0977 0.4885 1.140 750.7 483.2 1233.9 34,300 0.0207 0.0255 1683
Ruddy ACSS 900.0 45 / 7 0.1414 0.0943 0.2829 1.131 847.4 165.5 1012.9 15,800 0.0186 0.0233 1755
Canary ACSS 900.0 54 / 7 0.1291 0.1291 0.3873 1.162 847.7 310.2 1157.9 24,600 0.0184 0.0236 1756
Corncrake ACSS 954.0 20 / 7 0.2184 0.0971 0.2913 1.165 898.5 175.5 1074.0 16,700 0.0175 0.0219 1834
Redbird ACSS 954.0 24 / 7 0.1994 0.1329 0.3987 1.196 898.8 328.7 1227.5 26,000 0.0174 0.0217 1859
Rail ACSS 954.0 45 / 7 0.1456 0.0971 0.2913 1.165 898.5 175.5 1074.0 16,700 0.0175 0.0220 1824
Towhee ACSS 954.0 48 / 7 0.1410 0.1097 0.3291 1.175 898.8 224.0 1122.8 19,700 0.0175 0.0218 1842
Canvasback ACSS 954.0 30 / 19 0.1783 0.1070 0.5350 1.248 900.5 579.6 1480.1 41,100 0.0172 0.0214 1897
Snowbird ACSS 1033.5 42 / 7 0.1569 0.0872 0.2616 1.203 973.9 141.5 1115.4 15,400 0.0162 0.0204 1924
Ortolan ACSS 1033.5 45 / 7 0.1515 0.1010 0.3030 1.212 972.8 189.9 1162.7 18,100 0.0162 0.0204 1921
Curlew ACSS 1033.5 54 / 19 0.1383 0.1383 0.4149 1.245 972.8 356.0 1328.8 28,200 0.0161 0.0206 1924
Bluejay ACSS 1113.0 45 / 7 0.1573 0.1049 0.3747 1.258 1048.7 204.8 1253.5 19,500 0.0150 0.0190 2017
Finch ACSS 1113.0 54 / 19 0.1436 0.0862 0.4310 1.293 1053.9 376.1 1430.0 30,400 0.0150 0.0193 2015
Cardinal ACSS 954.0 54 / 7 0.1329 0.1329 0.3987 1.196 898.3 328.7 1227.0 26,000 0.0174 0.0223 1825
Bunting ACSS 1192.5 45 / 7 0.1628 0.1085 0.3255 1.302 1123.4 219.1 1342.5 20,900 0.0140 0.0178 2110
Grackle ACSS 1192.5 54 / 19 0.1486 0.0892 0.4460 1.338 1128.6 402.8 1531.4 32,600 0.0140 0.0180 2108
Bittern ACSS 1272.0 45 / 7 0.1681 0.1121 0.3363 1.345 1197.7 233.9 1431.6 22,300 0.0131 0.0167 2200
Pheasant ACSS 1272.0 54 / 19 0.1535 0.0921 0.4605 1.382 1204.3 429.4 1633.7 34,100 0.0131 0.0169 2200
Dipper ACSS 1351.0 45 / 7 0.1733 0.1155 0.3465 1.386 1272.9 248.3 1521.2 23,700 0.0124 0.0158 2289

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
407 Information on this sheet subject to change without notice.
20140925 Copyright © 2018, American Wire Group, Inc.
ACSS

DISTRIBUTION CABLES
TRANSMISSION.&
Item # Size Stranding Dia. Dia. Dia. Dia. Weight Weight Weight Rated Resist. Resist. Ampacity
AWG Al/St Ind. Ind. Steel Complete /MFT /MFT /MFT Strength DC@20°C AC@75°C
or Wire Wire Core Cable Aluminum Steel Total (lb) /MFT /MFT
KCMIL (in) (in) (in) (in) (lb) (lb) (lb) (ohm) (ohm)
Martin ACSS 1351.0 54 / 19 0.1582 0.0949 0.4745 1.424 1279.1 455.9 1735.0 36,200 0.0123 0.0160 2288
Bobolink ACSS 1431.0 45 / 7 0.1783 0.1189 0.3567 1.427 1347.5 263.1 1610.6 25,100 0.0117 0.0150 2375
Plover ACSS 1431.0 54 / 19 0.1628 0.0977 0.4885 1.465 1354.6 483.2 1837.8 38,400 0.0117 0.0151 2375
Nuthatch ACSS 1510.0 45 / 7 0.1832 0.1221 0.3663 1.466 1422.5 277.5 1700.0 26,500 0.0111 0.0143 2459
Parrot ACSS 1510.0 54 / 19 0.1672 0.1003 0.5015 1.505 1428.8 509.2 1938.0 40,500 0.0110 0.0144 2460
Ratite ACSS 1590.0 42 / 7 0.1946 0.1081 0.3243 1.492 1498.1 217.5 1715.6 23,400 0.0105 0.0136 2543
Lapwing ACSS 1590.0 45 / 7 0.1880 0.1253 0.3759 1.504 1498.1 292.2 1790.3 27,900 0.0105 0.0136 2543
Falcon ACSS 1590.0 54 / 19 0.1716 0.1030 0.5150 1.544 1505.0 537.0 2042.0 42,600 0.0105 0.0137 2545
Chukar ACSS 1780.0 84 / 19 0.1456 0.0874 0.4370 1.602 1685.4 386.7 2072.1 35,400 0.0094 0.0122 2751
Mockingbird ACSS 2034.0 72 / 7 0.1681 0.1121 0.3363 1.681 1925.7 233.9 2159.6 27,200 0.0083 0.0110 2960
Roadrunner ACSS 2057.0 76 / 19 0.1645 0.0768 0.3840 1.700 1946.5 298.6 2245.1 31,700 0.0082 0.0108 2992
Bluebird ACSS 2156.0 84 / 19 0.1602 0.0961 0.4805 1.762 2040.4 467.5 2507.9 42,100 0.0078 0.0103 3106
Kiwi ACSS 2167.0 72 / 7 0.1735 0.1157 0.3471 1.735 2051.4 249.2 2300.6 29,000 0.0078 0.0104 3080
Thrasher ACSS 2312.0 76 / 19 0.1744 0.0814 0.4070 1.802 2187.9 335.4 2523.3 35,600 0.0073 0.0098 3218
Joree ACSS 2515.0 76 / 19 0.1819 0.0849 0.4245 1.880 2380.1 364.9 2745.0 38,700 0.0067 0.0092 3390

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 407
Copyright © 2018, American Wire Group, Inc. 20140925
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
AAC

DISTRIBUTION CABLES
TRANSMISSION.&
Applications
Stranded 1350 aluminum conductors shown in this section of data are classified as follows:
Class AA For bare conductors usually used in overhead lines.
Class A For conductors to be covered with weather-resistant materials and for bare conductors
where greater flexibility is required.Compact strand conductor for use in bare overhead applications
or for use with weather-resistant coverings or insulations is also available.
Classes refer to stranding and are an indication of relative conductor flexibility, AA being the least
flexible, C the most flexible.

Construction
Aluminum alloy 1350-H19 wires, concentrically stranded.

Specifications
AAC bare conductors meet or exceed the following ASTM specifications:
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
• B-231 Aluminum Conductors, Concentric-Lay-Stranded
• B-400 Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors
Notes
• Resistance is calculated using ASTM standard increments of stranding and metal conductivity of
52.5% IACS, AC resistance at 60Hz.
• Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq.ft
sun, .05 coefficients of emissivity and absorption.

Item # Size No. of CLASS Diameter Diameter Cross Weight Rated Resistance Resistance Rating
AWG Wires Individual Complete Sectional /MFT Breaking /MFT /MFT (amp)
Wire Cable O.D. Area (lb) Strength DC 20°C AC 75°C
(in) (in) (in2) (lb) (ohm) (ohm)
Peachbell 6 7 A .0612 .184 .0206 24.6 563 .658 .805 103
Rose 4 7 A .0772 .232 .0328 39.2 881 .414 .506 138
Iris 2 7 A & AA .0974 .292 .0521 62.3 1350 .260 .318 185
Pansy 1 7 A & AA .1093 .328 .0657 99.1 1640 .207 .252 214
Poppy 1/0 7 A & AA .1228 .368 .0829 78.5 1990 .164 .202 247
Aster 2/0 7 A & AA .1379 .414 .1045 124.9 2510 .130 .159 286
Phlox 3/0 7 A & AA .1548 .464 .1318 157.5 3040 .103 .126 331
Oxlip 4/0 7 A & AA .1739 .522 .1662 198.6 3830 .0817 .0999 383
Sneezewort 250 7 AA .1890 .567 .1964 234.7 4520 .0691 .0846 425
Valerian 250 19 A .1147 .574 .1964 234.7 4660 .0691 .0846 426
Daisy 266.8 7 A & AA .1953 .586 .2095 250.5 4830 .0648 .0793 443
Laurel 266.8 19 A .1185 .593 .2095 250.5 4970 .0648 .0793 444
Peony 300 19 A .1257 .629 .2356 286.1 5480 .0576 .0706 478
Tulip 336.1 19 A .1331 .666 .2642 315.8 6150 .0514 .0630 513
Daffodil 350 19 A .1357 .679 .2749 328.6 6390 .0494 .0605 526
Canna 397.5 19 A & AA .1447 .724 .3122 373.2 7110 .0435 .0534 570
Goldentuft 450 19 AA .1538 .769 .3534 422.4 7890 .0384 .0472 616
Cosmos 477 19 AA .1584 .793 .3746 447.8 8360 .0362 .0445 639
Syringa 477 37 A .1135 .795 .3746 447.8 8690 .0362 .0445 639
Zinnia 500 19 AA .1622 .811 .3927 469.4 8760 .0346 .0425 658
Hyacinth 500 37 A .1162 .813 .329 469.4 9110 .0346 .0425 658

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 403
Copyright © 2018, American Wire Group, Inc. 20140921
AAC
DISTRIBUTION CABLES
TRANSMISSION &

Item # Size No. of CLASS Diameter Diameter Cross Weight Rated Resistance Resistance Rating
AWG Wires Individual Complete Sectional /MFT Breaking /MFT /MFT (amp)
Wire Cable O.D. Area (lb) Strength DC 20°C AC 75°C
(in) (in) (in2) (lb) (ohm) (ohm)
Dahlia 556.5 19 AA .1711 .856 .4371 522.4 9750 .0311 .0382 703
Mistletoe 556.5 37 A .1226 .858 .4371 522.4 9940 .0311 .0382 704
Meadowsweet 600 37 A & AA .1273 .891 .4712 563.2 10700 .0288 .0355 738
Orchid 636 37 A & AA .1311 .918 .4995 597.0 11400 .0272 .0335 765
Heuchera 650 37 AA .1326 .928 .5105 610.2 11600 .0266 .0328 775
Verbena 700 37 AA .1375 .963 .5498 657.1 12500 .0247 .0305 812
Flag 700 61 A .1071 .964 .5498 657.1 12900 .0247 .0305 812
Violet 715.5 37 AA .1391 .974 .5620 671.7 12800 .0242 .0299 823
Nasturtium 715.5 61 A .1083 .975 .5620 671.7 13100 .0242 .0299 823
Petunia 750 37 AA .1424 .997 .5891 704.0 13100 .0230 .0286 847
Cattail 750 61 A .1109 .998 .5891 704.0 13500 .0230 .0286 847
Arbutus 795 37 AA .1446 1.026 .6244 746.3 13900 .0217 .0271 878
Lilac 795 61 A .1142 1.028 .6244 746.3 14300 .0217 .0270 879
Cockscomb 900 37 AA .1560 1.092 .7069 844.9 15400 .0192 .0239 948
Snapdragon 900 61 A .1215 1.094 .7069 844.9 15900 .0192 .0239 948
Magnolia 954 37 AA .1606 1.124 .7493 895.6 16400 .0181 .0226 982
Goldenrod 954 61 A .1251 1.126 .7493 895.6 16900 .0181 .0226 983
Hawkweed 1000 37 AA .1644 1.150 .7854 938.7 17200 .0173 .0216 1010
Camellia 1000 61 A .1280 1.152 .7854 938.7 17700 .0173 .0216 1011
Bluebell 1033.5 37 AA .1671 1.170 .8117 970.2 17700 .0167 .0210 1031
Larkspur 1033.5 61 A .1302 1.172 .8117 970.2 18300 .0167 .0210 1032
Marigold 1113 61 A & AA .1351 1.216 .8742 1045 19700 .0155 .0195 1079
Hawthorn 1192.5 61 A & AA .1398 1.258 .9366 1119 21000 .0145 .0183 1124
Narcissus 1272 61 A & AA .1444 1.300 .9990 1194 22000 .0136 .0173 1169
Columbine 1351.5 61 A & AA .1489 1.340 1.062 1269 23400 .0128 .0163 1212
Carnation 1431 61 A & AA .1532 1.379 1.124 1343 24300 .0121 .0155 1253
Gladiolus 1510.5 61 A & AA .1574 1.417 1.186 1418 25600 .0144 .0147 1294
Coreopsis 1590 61 AA .1614 1.454 1.249 1493 27000 .0109 .0141 1333
Jessamine 1750 61 AA .1694 1.525 1.374 1643 29700 .00988 .0129 1408
Cowslip 2000 91 A .1482 1.630 1.571 1877 32200 .00864 .0115 1518
Sagebrush 2250 91 A .1572 1.729 1.767 2131 37500 .00776 .0105 1612
Lupine 2500 91 A .1657 1.823 1.964 2370 41900 .00698 .00969 1706
Bitterroot 2750 91 A .1739 1.913 2.160 2607 46100 .00635 .00900 1793
Trillium 3000 127 A .1537 1.996 2.356 2844 50300 .00582 .00834 1874
Bluebonnet 3500 127 A .1660 2.158 2.749 3350 58700 .00499 .00756 2024

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
403 Information on this sheet subject to change without notice.
20140921 Copyright © 2018, American Wire Group, Inc.
AAAC 6201 Alloy

DISTRIBUTION CABLES
TRANSMISSION.&
Applications
Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-
strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteris-
tics. Aluminum alloy gives AAAC higher resistance to corrosion than ACSR.

Construction
Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399,
are concentric-lay stranded, similar in construction and appearance to 1350 grade aluminum con-
ductors. Standard 6201 alloy conductors were developed to fill the need for an economical conduc-
tor for overhead applications requiring higher strength than that obtainable with 1350 grade
aluminum conductors, but without a steel core. The DC resistance at 20°C of the 6201-T81 conduc-
tors and of the standard ACSRs of the same diameter are approximately the same. Conductors of
the 6201-T81 alloys are harder and, therefore, have a greater resistance to abrasion than conductors
of 1350-H19 grade aluminum.

Specifications
AAAC bare conductor meets or exceeds the following ASTM specifications:
• B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
Notes
• Resistance is calculated using ASTM standard increments of stranding and metal conductivity of
52.5% IACS, AC resistance at 60Hz.
• Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq.ft
sun, .05 coefficients of emissivity and absorption

Item # Size KCM Strand Approx EC Stranding Diameter Diameter Cross Weight Rated Rating
KCM Cond. with Individual Complete Sectional /MFT Breaking (amp)
Equivalent Wire Cable Area (lb) Strength
Resistance (in) (in) (in2) (lb)
Akron 30.58 7/w 6 6/1 .0661 .198 .0240 28.7 1110 107
Alton 48.69 7/w 4 6/1 .0834 .250 .0382 45.7 1760 143
Ames 77.47 7/w 2 6/1 .1052 .316 .0608 72.7 2800 191
Azusa 123.3 7/w 1/0 6/1 .1327 .398 .0968 115.7 4460 256
Anaheim 155.4 7/w 2/0 6/1 .1490 .447 .1221 145.9 5390 296
Amherst 195.7 7/w 3/0 6/1 .1672 .502 .1537 183.7 6790 342
Alliance 246.9 7/w 4/0 6/1 .1878 .563 .1939 231.8 8560 395
Butte 312.8 19/w 266.8 26/7 .1283 .642 .2456 293.6 11000 460
Canton 394.5 19/w 336.4 26/7 .1441 .721 .3098 370.3 13300 532
Cairo 465.4 19/w 397.5 26/7 .1565 .783 .3655 436.9 15600 590
Darien 559.5 19/w 477.0 26/7 .1716 .858 .4394 525.2 18800 663
Elgin 652.4 19/w 556.5 26/7 .1853 .927 .5124 612.4 21900 729
Flint 740.8 37/w 636.0 26/7 .1415 .991 .5818 695.5 24400 790
Greely 927.2 37/w 795.0 26/7 .1583 1.108 .7282 870.4 30500 908

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 404
Copyright © 2018, American Wire Group, Inc. 20160418
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
ACAR

DISTRIBUTION CABLES
TRANSMISSION.&
Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. A good
strength-to-weight ratio makes ACAR applicable where both ampacity and strength are prime con-
siderations in line design; for equal weight, ACAR offers higher strength and ampacity than ACSR.

Construction
Concentric-stranded cable formed by a core of 6201-T81 aluminum alloy wires surrounded by 1350
H-19 aluminum wires concentrically stranded over the alloy core. Some designs have 1350 alu-
minum wires and 6201 alloy wires intercalated in the same layer.
Features
Very good ratio Tensile Strength to Weight. Highly resistant to corrosion.

Standards
• B230 Aluminum 1350-H19 Wire for Electrical Purposes.
• B398 Aluminum-Alloy 6201-T81 Wire for Electrical Purposes.
• B524 Concentric-Lay-Stranded Aluminum Conductors, Aluminum-Alloy Reinforced (ACAR,
1350/6201).

Item # Size Stranding Diameter Diameter Diameter Weight Rated Resistance. Resistance Allowable
KCMIL (EC/6201) Individual Individual Complete /MFT Strength DC@20°C AC@75°C Ampacity
Wires – 6201 Wires – 1350 Cable (lb) (lb) (ohms) (ohms) (amp)
(in) (in) (in)
ACAR-355.0 355.0 12/7 0.1367 0.1367 0.6830 332.1 8500 0.0514 0.0624 519
ACAR-465.9 465.9 12/7 0.1566 0.1566 0.7830 435.8 11000 0.0392 0.0477 616
ACAR-503.6 503.6 12/7 0.1628 0.1628 0.8140 471.1 11900 0.0362 0.0441 646
ACAR-653.1 653.1 12/7 0.1854 0.1854 0.9270 611.0 15400 0.0279 0.0342 760
ACAR-739.8 739.8 30/7 0.1414 0.1414 0.9900 692.7 15300 0.0240 0.0296 831
ACAR-739.8 739.8 18/19 0.1414 0.1414 0.9900 691.6 18800 0.0252 0.0308 814
ACAR-853.7 853.7 30/7 0.1519 0.1519 1.0630 799.3 17500 0.0208 0.0257 907
ACAR-853.7 853.7 18/19 0.1519 0.1519 1.0630 798.0 21500 0.0218 0.0268 890
ACAR-927.2 927.2 30/7 0.1583 0.1583 1.1080 868.2 19000 0.0192 0.0238 955
ACAR-927.2 927.2 18/19 0.1583 0.1583 1.1080 866.7 23400 0.0201 0.0247 936
ACAR-1024.5 1024.5 30/7 0.1664 0.1664 1.1650 959.3 20900 0.0173 0.0216 1015
ACAR-1024.5 1024.5 18/19 0.1664 0.1664 1.1650 957.7 25800 0.0182 0.0225 995
ACAR-1081.0 1081.0 30/7 0.1709 0.1709 1.1960 1012.1 22100 0.0164 0.0205 1048
ACAR-1081.0 1081.0 18/19 0.1709 0.1709 1.1960 1010.5 27200 0.0172 0.0213 1028
ACAR-1109.0 1109.0 30/7 0.1731 0.1731 1.2120 1038.4 22700 0.0160 0.0200 1065
ACAR-1109.0 1109.0 18/19 0.1731 0.1731 1.2120 1036.6 27900 0.0168 0.0208 1044
ACAR-1172.0 1172.0 30/7 0.1780 0.1780 1.2460 1097.3 24000 0.0152 0.0190 1101
ACAR-1172.0 1172.0 18/19 0.1780 0.1780 1.2460 1095.5 29500 0.0159 0.0198 1080
ACAR-1197.0 1197.0 30/7 0.1799 0.1799 1.2590 1120.8 24500 0.0148 0.0187 1115
ACAR-1197.0 1197.0 18/19 0.1799 0.1799 1.2590 1118.9 30200 0.0156 0.0194 1094
ACAR-1280.0 1280.0 30/7 0.1860 0.1860 1.3020 1198.5 26200 0.0139 0.0175 1160
ACAR-1280.0 1280.0 18/19 0.1860 0.1860 1.3020 1196.5 32200 0.0146 0.0182 1139
ACAR-1361.0 1361.0 42/19 0.1494 0.1494 1.3440 1273.6 30300 0.0133 0.0168 1196
ACAR-1527.0 1527.0 42/19 0.1582 0.1582 1.4240 1428.8 33600 0.0118 0.0151 1314
ACAR-1703.0 1703.0 42/19 0.1671 0.1671 1.5040 1593.5 37500 0.0106 0.0137 1363
ACAR-1933.0 1933.0 42/19 0.1780 0.1780 1.6020 1808.8 42500 0.0094 0.0123 1465
ACAR-2267.0 2267.0 42/19 0.1928 0.1928 1.7350 2142.0 49900 0.0081 0.0108 1594
ACAR-2493.0 2493.0 72/19 0.1655 0.1655 1.8210 2356.9 50400 0.0072 0.0099 1687
ACAR-2493.0 2493.0 54/37 0.1655 0.1655 1.8210 2354.5 57600 0.0074 0.0101 1670

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 406
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
TP
Twisted Pair

DISTRIBUTION CABLES
TRANSMISSION.&
Applications
TP Twisted Pair Conductor bare aluminum construction, is designed for use in overhead applica-
tions subject to Aeolian vibration and galloping due to wind and ice. TP Conductor can be strung to
the maximum allowable tension limits without the need for additional vibration protection.

Construction
TP Conductor is composed of two identical bare conductors twisted together with a left-hand lay.
This gives the cable a rectangular spiral shape. This spiral shape disrupts the forces created by
steady cross winds which cause cable vibration, by presenting a continuously changing projected
cable diameter to the wind. This spiral shape, together with less torsional stiffness and varying
bending stiffness also reduces or eliminates cable galloping due to combined ice and wind loads.
The component conducts of TP can be conductor types AAC, AAAC, ACAR, ACSR, AAC/TW or
ACSR/TW meeting the requirements of the appropriate ASTM standards.

Specifications
TP Conductor meets or exceeds the following ASTM specifications for the subconductor of each as-
sembly:
• B-911/B-911M for Twisted Pair Conductor
• B-231 Aluminum Conductor, Concentric-Lay Stranded.
• B-232 Aluminum Conductor, Concentric-Lay Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors.
• B-524 Concentric-Lay Stranded Aluminum Conductors, Aluminum Alloy Reinforced (ACAR,
1350/6201)
• B-779 Shaped Wire Compact Concentric-Lay Stranded Aluminum Conductors, Steel Reinforced
(ACSR/TW.)
Notes
• Resistance is calculated using ASTM standard increments of stranding and metal conductivity of
52.5% IACS, AC resistance at 60Hz.
• Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq.ft
sun, .05 coefficients of emissivity and absorption.

Item # Conductor Construction Total Stranding Stranding Outer Equivalent Weight Weight Weight Rated Rating
Type Kcmil Aluminum Steel Dimension Diameter /MFT /MFT /MFT Breaking (amp)
(in) (in) Alum Steel Total Strength
(lb) (lb) (lb) (lb)
Lily TP AAC 2x#3 105.2 7x0.0867 N/A 0.260x0.520 0.426 99.0 N/A 99.0 2180 272
Ames TP AAAC 2x#2 154.9 7x0.1052 N/A 0.316x0.632 0.517 145.4 N/A 145.4 5600 328
Swallow TP ACSR 2x#3 105.2 6x0.0937 1x0.0937 0.281x0.562 0.460 98.4 46.4 144.8 4600 275
Iris TP AAC 2x#2 132.7 7x0.0974 N/A 0.292x0.584 0.478 124.6 N/A 124.6 2700 316
SparrowTP ACSR 2x#2 132.7 6x0.1052 1x0.1052 0.316x0.631 0.517 124.0 59.0 183.0 5700 316
Pansy TP AAC 2x#1 167.4 7x0.1093 N/A 0.328x0.656 0.537 157.0 N/A 157.0 3280 367
Robin TP ACSR 2x#1 167.4 6x0.1181 1x0.1181 0.355x0.710 0.581 156.4 74.0 230.4 7100 371
Poppy TP AAC 2x1/0 211.2 7x0.1228 N/A 0.368x0.736 0.602 198.2 N/A 198.2 3980 426
Azuza TP AAAC 2x1/0 246.6 7x0.1327 N/A 0.396x0.796 0.652 231.4 N/A 231.4 8920 437
Raven TP ACSR 2x1/0 211.2 6x0.1327 1x0.1327 0.396x0.790 0.652 197.2 93.2 290.4 8760 420
Aster TP AAC 2x2/0 266.2 7x0.1379 N/A 0.414x0.828 0.678 250.0 N/A 250.0 5020 495
Anaheim TP AAAC 2x2/0 310.8 7x0.1490 N/A 0.447x0.894 0.732 291.8 N/A 291.8 10780 510
Quail TP ACSR 2x2/0 266.2 6x0.1489 1x0.1489 0.447x0.894 0.732 248.6 117.6 366.2 10600 484
Phlox TP AAC 2x3/0 335.6 7x0.1548 N/A 0.464x0.926 0.760 315.0 N/A 315.0 6080 574
Amherst TP AAAC 2x3/0 391.4 7x0.1672 N/A 0.502x1.004 0.822 367.4 N/A 367.4 13580 592
Pigeon TP ACSR 2x3/0 335.6 6x0.1672 1x0.1672 0.502x1.004 0.822 313.4 148.2 462.0 13240 582
Oxlip TP AAC 2x4/0 423.2 7x0.1739 N/A 0.552x1.044 0.854 397.2 N/A 397.2 7660 667
Alliance TP AAAC 2x4/0 493.8 7x0.1878 N/A 0.563x1.126 0.922 463.6 N/A 463.6 17120 692
Penguin TP ACSR 2x4/0 423.2 6x0.1878 1x0.1878 0.563x1.126 0.922 395.4 188.8 582.2 16700 642

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 405
Copyright © 2018, American Wire Group, Inc. 20140921
TP
Twisted Pair
DISTRIBUTION CABLES
TRANSMISSION &

Item # Conductor Construction Total Stranding Stranding Outer Equivalent Weight Weight Weight Rated Rating
Type Kcmil Aluminum Steel Dimension Diameter /MFT /MFT /MFT Breaking (amp)
(in) (in) Alum Steel Total Strength
(lb) (lb) (lb) (lb)
Jaeger TP ACSR 2x228.2 456.4 18x0.1126 1x0.1126 0.536x1.126 0.922 428.5 67.1 495.6 12200 720
Daisy TP AAC 2x266.8 533.6 7x0.1953 N/A 0.586x1.172 0.959 501 N/A 501 9700 774
Butte TP AAAC 2x266.8 533.6 19x0.1283 N/A 0.642x1.284 1.051 587.2 N/A 587.2 22000 810
Waxwing TP ACSR 2x266.8 533.6 18x0.1217 1x0.1217 0.609x1.218 0.997 501 78.6 580 13800 789
Partridge TP ACSR 2x266.8 533.6 26x0.1013 7x0.0788 0.642x1.284 1.051 504 230 734 22600 810
Tulip TP AAC 2x336.4 672.8 19x0.1331 N/A 0.666x1.332 1.090 632 N/A 632 12300 902
Merlin TP ACSR 2x336.4 672.8 18x0.1387 1x0.1367 0.684x1.368 1.120 632 100 732 17400 917
Linnett TP ACSR 2x336.4 672.8 26x0.1137 7x0.0884 0.721x1.442 1.180 634 292 926 28200 923
Canna TP AAC 2x397.5 795.0 19x0.1447 N/A 0.724x1.448 1.185 746 N/A 746 14200 984
Chickadee TP ACSR 2x397.5 795.0 18x0.1486 1x0.1486 0.743x1.486 1.216 746 118 864 19900 1001
Ptarmigan TP ACSR 2x397.5 795.0 20x0.1400 7x0.0626 0.752x1.504 1.231 747 146 893 22200 1007
Ibis TP ACSR 2x397.5 795.0 26x0.1236 7x0.0961 0.783x1.566 1.282 750 344 1094 32600 1030
Cosmos TP AAC 2x477.0 954.0 19x0.1584 N/A 0.793x1.586 1.298 896 N/A 896 16700 1108
Pelican TP ACSR 2x447.0 954.0 18x0.1628 1x0.1628 0.814x1.628 1.333 896 140 1036 23600 1128
Taller TP ACSR 2x477.0 954.0 20x0.1544 7x0.0686 0.823x1.647 1.347 895 175 1070 26400 1134
Flicker-TP ACSR 2x477.0 954.0 24x0.1410 7x0.0940 0.846x1.692 1.385 900 328 1228 34400 1153
Hawk TP ACSR 2x477.0 954.0 26x0.1354 7x0.1053 0.858x1.716 1.405 900 414 1314 39000 1162
Dahila TP AAC 2x556.5 1113 19x0.1711 N/A 0.856x1.712 1.401 1045 N/A 1045 19500 1224
Flycatcher TP ACSR 2x516.8 1033.5 18x0.1694 1x0.1694 0.847x1.694 1.387 970 152 1122 25500 1188
Creeper TP ACSR 2x516.8 1033.5 20x0.1607 7x0.0714 0.857x1.714 1.403 974 190 1164 28300 1194
OspreyTP ACSR 2x556.5 1113 18x0.1758 1x0.1758 0.879x1.758 1.439 1044 164 1208 27400 1247
Kinglet TP ACSR 2x556.5 1113 20x0.1667 7x0.0741 0.889x1.778 1.455 1050 204 1254 30500 1254
Parakeet TP ACSR 2x556.5 1113 24x0.1523 7x0.1015 0.914x1.828 1.496 1050 384 1434 39600 1275
Dove TP ACSR 2x556.5 1113 26x0.1463 7x0.1138 0.927x1.854 1.518 1050 482 1532 45200 1290
Day Lily TP AAC 2x596.0 1192 19x0.1771 N/A 0.886x1.771 1.450 1119 N/A 1119 20400 1279
Kittiwake TP ACSR 2x596.0 1192 18x0.1820 1x0.1820 0.910x1.820 1.490 1119 175 1294 29800 1304
Squab TP ACSR 2x605.0 1210 20x0.1739 7x0.0773 0.928x1.855 1.518 1141 222 1383 33200 1324
Orchid TP AAC 2x636.0 1272 37x0.1311 N/A 0.918x1.836 1.503 1194 N/A 1194 22800 1335
Kingbird TP ACSR 2x636.0 1272 18x0.1880 1x0.1880 0.940x1.880 1.539 1194 186 1380 31400 1359
Turacos TP ACSR 2x636.0 1272 20x0.1783 7x0.0792 0.951x1.902 1.557 1200 234 1434 34800 1368
Rook TP ACSR 2x636.0 1272 24x0.1626 7x0.1085 0.977x1.954 1.599 1200 438 1638 45400 1391
Gloxinia TP AAC 2x666.6 1333 37x0.1342 N/A 0.939x1.879 1.538 1251 N/A 1251 23800 1375
Siskin TP ACSR 2x666.6 1334 20x0.1826 7x0.0812 1.974x1.948 1.594 1258 246 1504 36600 1410
Flamingo TP ACSR 2x666.6 1334 24x0.1667 7x0.1111 1.000x2.000 1.637 1258 450 1718 47600 1434
Violet TP AAC 2x715.5 1431 37x0.1391 N/A 1.974x1.945 1.594 1343 N/A 1343 25600 1439
Dunlin TP ACSR 2x715.5 1431 20x0.1891 7x0.0840 1.005x2.016 1.650 1350 262 1612 39200 1474
Arbutus TP AAC 2x795.0 1590 37x0.1466 N/A 1.026x2.052 1.680 1493 N/A 1493 27800 1536
Tern TP ACSR 2x795.0 1590 45x0.1329 7x0.0886 1.064x2.128 1.742 1500 292 1792 44200 1577
Drake TP ACSR 2x795.0 1590 26x0.1749 7x0.1360 1.108x2.216 1.814 1500 688 2188 63000 1620
Cockscomb TP AAC 2x900.0 1800 37x0.1580 N/A 1.092x2.184 1.788 1690 N/A 1690 30800 1658
Surfbird TP ACSR 2x874.5 1749 20x0.2091 7x0.0929 1.115x2.23 1.825 1650 322 1972 47600 1674
Twinstone TP ACSR 2x900.0 1800 20x0.2121 7x0.0943 1.131x2.262 1.851 1698 332 2030 48200 1703
Bluebell TP AAC 2x1033.5 2067 37x0.1671 N/A 1.170x2.340 1.915 1940 N/A 1940 35400 1801
Marigold TP AAC 2x1113.5 2226 61x0.1351 N/A 1.216x2.432 1.991 2090 N/A 2090 39400 1882
Ortolan TP ACSR 2x1033.5 2067 45x0.1515 7x0.1010 1.212x2.424 1.984 1948 380 2328 55400 1853
Bluejay TP ACSR 2x1113.0 2226 45x0.1573 7x0.1049 1.258x2.516 2.059 2100 410 2510 59600 1939

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
405 Information on this sheet subject to change without notice.
20140921 Copyright © 2018, American Wire Group, Inc.
ASCR/TW

DISTRIBUTION CABLES
TRANSMISSION.&
APPLICATION
Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductor, Steel-Reinforced (ACSR/TW)
is designed for use as a bare overhead conductor. There are two designs of ACSR/TW. One design
gives an equal area of aluminum when compared to the standard ACSR conductor sizes. The other
design gives an overall outside diameter equal to standard ACSR conductor sizes. Use of this con-
ductor in the equal area design allows equal ampacity in a smaller diameter conductor when com-
pared with standard ACSR conductor. Use of this conductor in the equal diameter design allows
more ampacity in an equal diameter conductor when compared with standard ACSR conductor.

SPECIFICATIONS
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
• B-231 Aluminum Conductors, Concentric-Lay-Stranded
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
• B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
• B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel
Reinforced (ACSR)
• B-779 Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Steel-Reinforced
(ACSR/TW).
CONSTRUCTION
Aluminum alloy 1350-H19 trapezoidal shaped wires, concentrically stranded about a steel core. Core
wire for ACSR/TW is available with class A, B, or C galvanizing; “aluminized” aluminum coated (AZ);
or aluminum-clad (AW1). Additional corrosion protection is available through the application of
grease to the core or infusion of the complete cable with grease.

NOTES
* Ampacity calculated assuming: ambient 250°C, conductor 75°C, wind 2 ft./sec., sun.

Item # Conductor Conductor Type Stranding Outside Diameter Weight Rated Resistance Allowable
Size Area Area Code No. Al St Complete Steel Total Aluminum Steel Strength DC@20°C AC@75°C Ampacities
Al Total Layers Conductor Core (lb/MFT) (lb/MFT) (lb/MFT) (lb) (OMS/ (OMS/ *
(sq.in) (sq.in) of Al (in) (in) MFT) MFT)
Merlin/TW 336.4 0.2642 0.2788 6 2 14 1x0.1367 0.630 0.1367 365.0 315.5 49.5 8560 0.0510 0.0625 508
Flicker/TW 477.0 0.3747 0.4233 13 2 18 7x0.0940 0.776 0.2820 612.8 448.4 164.4 17200 0.0357 0.0437 641
Hawk/TW 477.0 0.3746 0.4356 16 2 18 7x0.1053 0.789 0.3159 655.0 448.7 206.3 19400 0.0356 0.0435 645
Parakeet/TW 556.5 0.4371 0.4937 13 2 18 7x0.1015 0.835 0.3045 714.9 523.2 191.7 20000 0.0306 0.0375 706
Dove/TW 556.5 0.4371 0.5083 16 2 20 7x0.1138 0.852 0.3414 764.5 523.5 241.0 22600 0.0305 0.0374 711
Swift/TW 636.0 0.4995 0.5133 3 3 27 1x0.1329 0.850 0.1329 646.0 599.2 46.8 13500 0.0272 0.0335 750
Rook/TW 636.0 0.4995 0.5643 13 2 19 7x0.1085 0.890 0.3255 816.0 597.9 219.1 22900 0.0268 0.0329 766
Grosbeak/TW 636.0 0.4995 0.5808 16 2 20 7x0.1216 0.908 0.3648 873.5 598.4 275.1 25400 0.0267 0.0327 772
Tern/TW 795.0 0.6244 0.6675 7 2 17 7x0.0886 0.960 0.2658 892.0 745.9 146.1 21000 0.0215 0.0266 869
Puffin/TW 795.0 0.6244 0.6919 10 2 18 7x0.1108 0.980 0.3324 975.3 746.9 228.4 25900 0.0215 0.0264 876
Condor/TW 795.0 0.6244 0.7053 13 2 20 7x0.1203 0.993 0.3639 1021.0 747.2 273.8 28200 0.0214 0.0264 880
Drake/TW 795.0 0.6244 0.7261 16 2 20 7x0.1360 1.010 0.4080 1092.0 747.8 344.2 31800 0.0213 0.0263 887
Phoenix/TW 954.0 0.7493 0.7876 5 3 30 7x0.0837 1.044 0.2511 1032.0 901.6 130.4 23700 0.0181 0.0224 967
Rail/TW 954.0 0.7493 0.8011 7 3 32 7x0.0971 1.061 0.2913 1075.0 900.0 175.0 25900 0.0180 0.0224 973
Cardinal/TW 954.0 0.7493 0.8464 13 2 20 7x0.1329 1.084 0.3987 1226.0 897.3 328.7 33500 0.0178 0.0221 985
Snowbird/TW 1033.5 0.8117 0.8534 5 3 30 7x0.0871 1.089 0.2613 1115.0 973.8 141.2 25700 0.0167 0.0208 1017
Ortolan/TW 1033.5 0.8117 0.8678 7 3 32 7x0.1010 1.102 0.3030 1165.0 975.2 189.8 28100 0.0167 0.0207 1021
Curlew/TW 1033.5 0.8117 0.9169 13 2 20 7x0.1383 1.129 0.4149 1327.0 971.1 355.9 36300 0.0165 0.0204 1036
Avocet/TW 1113.0 0.8742 0.9191 5 3 30 7x0.0904 1.129 0.2712 1201.0 1048.9 152.1 27500 0.0155 0.0193 1063
Bluejay/TW 1113.0 0.8742 0.9347 7 3 33 7x0.1049 1.143 0.3147 1257.0 1052.2 204.8 30300 0.0155 0.0193 1069
Finch/TW 1113.0 0.8742 0.9851 13 3 38 19x0.0862 1.185 0.4310 1429.0 1052.6 376.4 39100 0.0154 0.0191 1084
Oxbird/TW 1192.5 0.9366 0.9848 5 2 30 7x0.0936 1.167 0.2808 1286.0 1123.0 163.0 29500 0.0144 0.0180 1111
Bunting/TW 1192.5 0.9366 1.0013 7 3 34 7x0.1085 1.181 0.3255 1343.0 1124.0 219.0 32400 0.0144 0.0181 1114

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 419
Copyright © 2018, American Wire Group, Inc. 20160520
ASCR/TW
DISTRIBUTION CABLES
TRANSMISSION &

Item # Conductor Conductor Type Stranding Outside Diameter Weight Rated Resistance Allowable
Size Area Area Code No. Al St Complete Steel Total Aluminum Steel Strength DC@20°C AC@75°C Ampacities
Al Total Layers Conductor Core (lb/MFT) (lb/MFT) (lb/MFT) (lb) (OMS/ (OMS/ *
(sq.in) (sq.in) of Al (in) (in) MFT) MFT)

Grackel/TW 1192.5 0.9366 1.0554 13 3 38 19x0.0892 1.225 0.4460 1530.0 1127.0 403.0 41900 0.0144 0.0179 1130
Scissortail/TW 1272.0 0.9991 1.0505 5 3 30 7x0.0967 1.203 0.2901 1372.0 1198.0 174.0 31400 0.0135 0.0170 1152
Bittern/TW 1272.0 0.9990 1.0681 7 3 35 7x0.1121 1.220 0.3363 1433.0 1198.0 234.0 34600 0.0135 0.0170 1159
Pheasant/TW 1272.0 0.9990 1.1256 13 3 39 19x0.9210 1.264 0.4605 1632.0 1202.0 430.0 44100 0.0135 0.0168 1176
Dipper/TW 1351.0 1.0615 1.1348 7 3 35 7x0.1155 1.256 0.3465 1522.0 1274.0 248.0 36700 0.0127 0.0160 1202
Martin/TW 1351.0 1.0615 1.1959 13 3 42 19x0.0949 1.300 0.4745 1734.0 1278.0 456.0 46800 0.0127 0.0159 1219
Bobolink/TW 1431.0 1.1236 1.2017 7 3 36 7x0.1189 1.291 0.3567 1613.0 1350.0 263.0 38900 0.0120 0.0152 1243
Plover/TW 1431.0 1.1239 1.2664 13 3 44 19x0.0977 1.337 0.4885 1836.0 1353.0 483.0 49600 0.0120 0.0150 1262
Lapwing/TW 1590.0 1.2488 1.3351 7 3 36 7x0.1253 1.358 0.3759 1791.0 1499.0 292.0 42200 0.0183 0.0138 1323
Falcon/TW 1590.0 1.2488 1.4071 13 3 42 19x0.1030 1.408 0.5150 2040.0 1503.0 537.0 55100 0.0108 0.0136 1345
Chukar/TW 1780.0 1.3986 1.5120 8 3 37 19x0.0874 1.445 0.4370 2063.0 1676.0 387.0 50700 0.0096 0.0124 1420
Bluebird/TW 2156.0 1.0934 1.8312 8 4 64 19x0.0961 1.608 0.4805 2515.0 2047.0 468.0 61100 0.0080 0.0105 1586
Monongahela/TW 405.1 0.3181 0.3362 6 2 14 1x0.1520 0.680 0.1520 441.0 379.8 61.2 10200 0.0423 0.0519 569
Mohawk/TW 571.7 0.4490 0.5074 13 2 18 7x0.1030 0.846 0.3090 734.7 537.3 197.4 20700 0.0298 0.0365 718
Calumet/TW 565.3 0.4439 0.5165 16 2 18 7x0.1147 0.858 0.3438 714.8 523.1 191.7 22900 0.0300 0.0368 718
Mystic/TW 666.6 0.5236 0.5914 13 2 20 7x0.1111 0.913 0.3330 856.3 626.6 229.7 24000 0.0255 0.0314 790
Oswego/TW 664.8 0.5221 0.6072 16 2 20 7x0.1244 0.927 0.3732 913.4 625.4 288.0 26600 0.0255 0.0313 794
Nechako/TW 768.9 0.6039 0.6220 3 3 27 1x0.1520 0.930 0.1520 781.9 720.7 61.2 16400 0.0255 0.0278 843
Maumee/TW 768.2 0.6034 0.6819 13 2 20 7x0.1195 0.977 0.3585 987.8 722.1 265.7 27700 0.0222 0.0273 862
Wabash/TW 762.8 0.5992 0.6966 16 2 20 7x0.1331 0.990 0.3993 1047.0 717.0 330.0 30500 0.0222 0.0274 863
Kettle/TW 957.2 0.7518 0.8038 7 3 32 7x0.0973 1.060 0.2919 1079.0 902.8 176.2 26000 0.0180 0.0223 974
Fraser/TW 946.7 0.7436 0.8168 10 3 35 7x0.1154 1.077 0.3462 1142.0 894.0 248.0 29600 0.0180 0.0223 978
Columbia/TW 966.2 0.7589 0.8573 13 2 21 7x0.1338 1.092 0.4014 1241.0 908.0 333.0 34000 0.0176 0.0218 993
Suwannee/TW 959.6 0.7537 0.8762 16 2 22 7x0.1493 1.108 0.4479 1318.0 903.0 415.0 37000 0.0177 0.0218 996
Cheyenne/TW 1168.1 0.9175 0.9646 5 3 30 7x0.0926 1.155 0.2778 1260.0 1100.4 159.6 28900 0.0148 0.0185 1095
Genesee/TW 1158.0 0.9095 0.9733 7 3 33 7x0.1078 1.165 0.3234 1308.0 1092.0 216.0 31600 0.0149 0.0186 1095
Hudson/TW 1158.4 0.9098 1.0281 13 2 26 7x0.1467 1.196 0.4401 1489.0 1089.0 400.0 39600 0.0147 0.0183 1111
Catawba/TW 1272.0 0.9991 1.0505 5 3 30 7x0.0967 1.203 0.2901 1372.0 1198.0 174.0 31400 0.0135 0.0170 1152
Nelson/TW 1257.1 0.9874 1.0557 7 3 35 7x0.1115 1.213 0.3345 1417.0 1185.7 231.3 34200 0.0137 0.0172 1150
Yukon/TW 1233.6 0.9689 1.0925 13 3 38 19x0.0910 1.245 0.4550 1586.0 1166.5 419.5 42900 0.0139 0.0173 1154
Truckee/TW 1372.5 1.0780 1.1334 5 3 30 7x0.1004 1.248 0.3012 1481.0 1293.4 187.6 33400 0.0126 0.0159 1206
Mackenzie/TW 1359.7 1.0679 1.1418 7 3 36 7x0.1559 1.259 0.3477 1530.0 1280.0 250.0 36900 0.0127 0.0159 1206
Thames/TW 1334.6 1.3480 1.1809 13 3 39 19x0.0944 1.290 0.4720 1713.0 1261.6 451.4 46300 0.0128 0.0160 1210
St. Croix/TW 1467.8 1.1529 1.2124 5 3 33 7x0.1041 1.292 0.3123 1585.0 1383.0 202.0 35800 0.0117 0.0149 1256
Miramichi/TW 1455.3 1.1430 1.2222 7 3 36 7x0.1200 1.302 0.3600 1640.0 1372.0 268.0 39200 0.0118 0.0150 1256
Merrimack/TW 1433.6 1.1250 1.2677 13 3 39 19x0.0978 1.340 0.4890 1840.0 1356.0 434.0 49700 0.0119 0.0150 1264
Platte/TW 1569.0 1.2323 1.2957 5 3 33 7x0.1074 1.334 0.3222 1693.0 1478.0 215.0 38200 0.0110 0.0140 1306
Potomac/TW 1557.4 1.2232 1.3079 7 3 36 7x0.1241 1.345 0.3723 1755.0 1468.0 287.0 41900 0.0111 0.0140 1307
Rio Grande/TW 1533.3 1.2043 1.3571 13 3 39 19x0.1012 1.382 0.5060 1968.0 1449.0 519.0 53200 0.0112 0.0141 1316
Schuylkill/TW 1657.4 1.3020 1.3920 7 3 36 7x0.128 1.386 0.3840 1868.0 1563.0 305.0 44000 0.0104 0.0133 1356
Pecos/TW 1622.0 1.2739 1.4429 13 3 39 19x0.1064 1.424 0.5320 2107.0 1533.0 574.0 57500 0.0106 0.0133 1363
Pee Dee/TW 1758.6 1.3810 1.4770 7 3 37 7x0.1319 1.427 0.3957 1982.0 1658.0 324.0 46700 0.0098 0.0126 1404
James/TW 1730.6 1.3590 1.5314 13 3 34 19x0.1075 1.470 0.5375 2221.0 1636.0 585.0 59400 0.0099 0.0126 1415
Athabaska/TW 1949.6 1.5312 1.6377 7 3 44 7x0.1392 1.504 0.4176 2199.0 1838.0 361.0 51900 0.0088 0.0115 1491
Cumberland/TW 1926.9 1.5134 1.7049 13 3 42 19x0.1133 1.545 0.5665 2471.0 1821.0 650.0 65300 0.0089 0.0114 1507
Powder/TW 2153.8 1.6912 1.8290 8 4 64 19x0.0961 1.602 0.4805 2498.0 2030.0 468.0 61100 0.0080 0.0105 1584
Santee/TW 2627.3 2.0630 2.2268 8 4 64 19x0.1062 1.762 0.5310 3048.0 2477.0 571.0 74500 0.0066 0.0089 1768

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
419 Information on this sheet subject to change without notice.
20160520 Copyright © 2018, American Wire Group, Inc.
ACSS/TW

DISTRIBUTION CABLES
TRANSMISSION.&
APPLICATIONS
ACSS/TW is designed for overhead distribution and transmission lines. It is designed to operate
continuously at elevated temperatures up to 250°C without loss of strength, it sags less under emer-
gency electrical loadings than ACSR/TW, excellent self-damping properties, and its final sags are
not affected by long-term creep of aluminum. ACSS/TW is available in equal area and equal diame-
ter design. The equal area design allows equal ampacity in a smaller diameter conductor when
compared with a standard ACSS conductor. The equal diameter design allows more ampacity in an
equal diameter conductor when compared with a standard ACSS conductor. ACSS/TW also pro-
vides many design opportunities for new line construction: i.e., reduced tower cost, decreased sag,
increased self-damping properties, increased operating temperature and improved corrosion resist-
ance.

CONSTRUCTION
ACSS is a composite concentric-lay-stranded conductor. Steel strands form the central core of the
conductor with one or more layers of 63% minimum average conductivity aluminum 1350-0 wire
stranded around it. The steel core carries most or all of the mechanical load of the conductor due to
the "0" (fully annealed or soft) temper aluminum. Steel core wires are protected from corrosion by a
zinc-5% aluminum-mischmetal alloy coating. High strength steel core, aluminized, and aluminum
clad steel core is also available.

SPECIFICATIONS
• B500 Metallic Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced.
• B609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes.
• B802 Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Aluminum Conductors,
Steel Reinforced.
• B803 High-Strength Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Aluminum
and Aluminum-Alloy Conductors, Steel Reinforced.
• B856 Concentric-Lay-Stranded Aluminum Conductors, Coated Steel Supported (ACSS)
• B857 Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Sup-
ported (ACSS/TW).
NOTES
1)Data based on a nominal cable manufactured in accordance with ASTM B 857.
2)Resistance and ampacity based on an aluminum conductivity of 63% IACS at 20°C and a steel
conductivity of 8% IACS at 20°C.
3)Ampacity based on referenced conductor temperature, 25°C ambient temperature, 2 ft/sec wind,
in sun, with an emmisivity of 0.5 and a coefficient of solar absorption of 0.5, at sea level.
4)Rated breaking strength for standard core based on Class A zinc-5% aluminum-mischmetal alloy
coated steel core wire in accordance with ASTM B 802.
5)Rated strength for high strength core based on Class A zinc-5% aluminum-mischmetal alloy
coated high strength steel core wire in accordance with ASTM B 803.
6)The final design of a shaped wire compact conductor is contingent upon several factors such as:
layer diameter, wire width and wire thickness. The actual configuration of a given size may vary
between manufacturers. This may result in a slight variation in the number of wires, number of
layers and dimensions of individual wires from that shown in the chart.

Item # Size Type Cross Stranding Diameter Weight Rated Breaking Resistance Ampacity
KCMIL No. Sectional (in) (lb/MFT) Strength (lb) (ohm/mile) (amps)
Al/Total Layers No. x Dia./ St Complete Al St Total Standard High Ultra DC AC 75°C 100°C 150°C 200°C 250°C
(in)2 Wires St Wire Core Cable High 20°C 75°C
Linnet/ACSS/TW 336.4 16 0.2641/0.3070 2 18 7 x 0.0884 0.2652 0.659 315.9 145.5 461.4 11200 12300 14400 0.2588 0.3181 523 638 801 921 1021
Oriole/ACSS/TW 336.4 23 0.2642/0.3258 2 16 7 x 0.1059 0.3177 0.693 316.1 208.7 524.8 14800 16300 19100 0.2565 0.3151 533 650 816 940 1043
Flicker/ACSS/TW 477.0 13 0.3747/0.4233 2 18 7 x 0.0940 0.2820 0.776 447.8 164.5 612.3 13000 14200 16400 0.1831 0.2255 648 793 998 1151 1279
Hawk/ACSS/TW 477.0 16 0.3746/0.4356 2 18 7 x 0.1053 0.3159 0.789 448.1 206.4 654.5 15600 17100 19800 0.1825 0.2247 652 799 1005 1159 1289
Hen/ACSS/TW 477.0 23 0.3747/0.4621 2 16 7 x 0.1261 0.3783 0.825 448.3 296.0 744.3 21000 22700 26700 0.1809 0.2225 663 813 1024 1181 1315
Parakeet/ACSS/TW 556.5 13 0.4371/0.4937 2 18 7 x 0.1015 0.3045 0.835 522.4 191.8 714.2 15200 16600 19100 0.1569 0.1935 713 874 1102 1271 1415
Dove/ACSS/TW 556.5 16 0.4371/0.5083 2 20 7 x 0.1138 0.3414 0.852 522.9 241.0 763.9 18200 19900 23100 0.1564 0.1928 719 881 1111 1282 1427

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 418
Copyright © 2018, American Wire Group, Inc. 20140925
ACSS/TW
DISTRIBUTION CABLES
TRANSMISSION &

Item # Size Type Cross Stranding Diameter Weight Rated Breaking Resistance Ampacity
KCMIL No. Sectional (in) (lb/MFT) Strength (lb) (ohm/mile) (amps)
Al/Total Layers No. x Dia./ St Complete Al St Total Standard High Ultra DC AC 75°C 100°C 150°C 200°C 250°C
(in)2 Wires St Wire Core Cable High 20°C 75°C
Rook/ACSS/TW 636.0 13 0.4995/0.5643 2 18 7 x 0.1085 0.3255 0.890 597.0 219.1 816.1 17300 19000 21900 0.1373 0.1696 775 951 1200 1386 1544
Grosbeak/ACSS/TW 636.0 16 0.4995/0.5808 2 20 7 x 0.1216 0.3648 0.908 597.6 275.2 872.8 20700 22400 26000 0.1369 0.1689 781 958 1210 1398 1557
Scoter/ACSS/TW 636.0 23 0.4995/0.6160 2 18 7 x 0.1456 0.4368 0.953 597.6 394.6 992.2 27400 29700 35000 0.1356 0.1672 795 976 1234 1427 1591
Tern/ACSS/TW 795.0 7 0.6244/0.6675 2 17 7 x 0.0886 0.2658 0.960 745.2 146.1 891.3 14200 15200 17400 0.1105 0.1373 878 1080 1366 1580 1762
Puffin/ACSS/TW 795.0 11 0.6244/0.6919 2 18 7 x 0.1056 0.3168 0.980 745.9 228.5 974.4 17700 19200 22000 0.1101 0.1365 886 1090 1378 1595 1778
Condor/ACSS/TW 795.0 13 0.6244/0.7053 2 20 7 x 0.1213 0.3639 0.993 746.3 273.9 1020 21700 23300 26900 0.1098 0.1361 890 1095 1386 1604 1789
Drake/ACSS/TW 795.0 16 0.6244/0.7261 2 20 7 x 0.1360 0.4080 1.010 747.0 344.3 1091 25900 28000 32600 0.1095 0.1355 896 1103 1396 1616 1803
Canary/ACSS/TW 900.0 13 0.7069/0.7983 2 20 7 x 0.1291 0.3873 1.055 844.9 310.2 1155 24600 26400 30500 0.0970 0.1205 962 1185 1501 1739 1942
Phoenix/ACSS/TW 954.0 5 0.7493/0.7876 3 30 7 x 0.0837 0.2511 1.044 897.7 130.4 1028 14200 15200 17100 0.0927 0.1187 967 1189 1503 1740 1940
Rail/ACSS/TW 954.0 7 0.7493/0.8011 3 32 7 x 0.0971 0.2913 1.061 898.6 175.5 1074 16700 18000 20400 0.0926 0.1183 972 1196 1512 1750 1953
Cardinal/ACSS/TW 954.0 13 0.7493/0.8464 2 20 7 x 0.1329 0.3987 1.084 895.5 328.7 1224 26000 28000 32300 0.0915 0.1138 997 1229 1558 1806 2016
Snowbird/ACSS/TW 1033.5 5 0.8117/0.8534 3 30 7 x 0.0871 0.2613 1.089 972.5 141.2 1114 15400 16400 18500 0.0856 0.1098 1016 1251 1584 1834 2048
Ortolan/ACSS/TW 1033.5 7 0.8117/0.8678 3 32 7 x 0.1010 0.3030 1.102 972.5 189.9 1162 18100 19500 22000 0.0854 0.1095 1021 1257 1592 1843 2058
Curlew/ACSS/TW 1033.5 13 0.8117/0.9169 2 20 7 x 0.1383 0.4149 1.129 970.1 356.0 1326 28200 30300 35000 0.0845 0.1053 1048 1293 1641 1903 2126
Avocet/ACSS/TW 1113.0 5 0.8742/0.9191 3 30 7 x 0.0904 0.2712 1.129 1047 152.1 1199 16300 17500 19500 0.0794 0.1022 1063 1310 1661 1925 2150
Bluejay/ACSS/TW 1113.0 7 0.8742/0.9347 3 33 7 x 0.1049 0.3147 1.143 1048 204.8 1253 19500 21000 23800 0.0793 0.1019 1068 1317 1669 1935 2161
Finch/ACSS/TW 1113.0 13 0.8743/0.9852 3 38 19 x 0.0862 0.4310 1.185 1051 376.1 1427 30400 33200 38700 0.0789 0.1010 1084 1336 1695 1965 2196
Oxbird/ACSS/TW 1192.5 5 0.9366/0.9848 3 30 7 x 0.0936 0.2808 1.167 1122 163.1 1285 17500 18700 20900 0.0741 0.0957 1108 1367 1735 2013 2249
Bunting/ACSS/TW 1192.5 7 0.9366/1.0013 3 34 7 x 0.1085 0.3255 1.181 1123 219.1 1342 20900 22500 25400 0.0740 0.0954 1114 1374 1744 2023 2261
Grackle/ACSS/TW 1192.5 13 0.9366/1.0554 3 38 19 x 0.0892 0.4460 1.225 1126 402.8 1529 32600 35500 41500 0.0737 0.0944 1130 1395 1771 2055 2298
Scissortail/ACSS/TW 1272.0 5 0.9991/1.0505 3 30 7 x 0.0967 0.2901 1.203 1197 174 1371 18700 20000 22300 0.0695 0.0900 1152 1423 1807 2098 2346
Bittern/ACSS/TW 1272.0 7 0.9990/1.0681 3 35 7 x 0.1121 0.3363 1.220 1198 233.9 1432 22300 24000 27100 0.0694 0.0897 1159 1431 1817 2110 2360
Pheasant/ACSS/TW 1272.0 13 0.9990/1.1256 3 39 19 x 0.0921 0.4605 1.264 1201 429.4 1630 34100 37300 43000 0.0691 0.0887 1176 1452 1846 2143 2398
Dipper/ACSS/TW 1351.5 7 1.0615/1.1348 3 35 7 x 0.1155 0.3465 1.256 1273 248.3 1521 23700 25500 28800 0.0653 0.0847 1202 1485 1888 2194 2455
Martin/ACSS/TW 1351.5 13 1.0615/1.1959 3 42 19 x 0.0949 0.4745 1.300 1276 455.9 1732 36200 39600 45600 0.0650 0.0837 1220 1508 1918 2228 2494
Bobolink/ACSS/TW 1431.0 7 1.1236/1.2017 3 36 7 x 0.1189 0.3567 1.291 1347 263.1 1611 25100 27000 30500 0.0617 0.0802 1243 1538 1958 2276 2549
Plover/ACSS/TW 1431.0 13 1.1239/1.2664 3 44 19 x 0.0977 0.4885 1.337 1351 483.2 1834 38400 41900 48300 0.0614 0.0793 1263 1562 1989 2313 2590
Lapwing/ACSS/TW 1590.0 7 1.2488/1.3351 3 36 7 x 0.1253 0.3759 1.358 1498 292.2 1790 27900 29600 33500 0.0555 0.0727 1324 1640 2092 2435 2730
Falcon/ACSS/TW 1590.0 13 1.2488/1.4071 3 42 19 x 0.1030 0.5150 1.408 1501 537 2038 42600 46600 53700 0.0553 0.0717 1346 1668 2127 2477 2777
Chukar/ACSS/TW 1780.0 8 1.3986/1.5126 3 37 19 x 0.0874 0.4370 1.445 1675 386.7 2062 35300 38200 43900 0.0495 0.0652 1421 1764 2255 2630 2952
Bluebird/ACSS/TW 2156.0 8 1.6933/1.8309 4 64 19 x 0.0961 0.4805 1.608 2045 467.5 2512 42100 45500 51700 0.0412 0.0543 1601 1999 2573 3014 3396
Mohawk/ACSS/TW 571.7 13 0.4490/0.5074 2 18 7 x 0.1030 0.3090 0.846 536.6 197.5 734.1 15600 17100 19700 0.1527 0.1884 725 889 1121 1294 1441
Calumet/ACSS/TW 565.3 16 0.4439/0.5162 2 20 7 x 0.1146 0.3441 0.858 531.2 244.4 775.6 18400 20200 23500 0.1540 0.1898 725 890 1122 1295 1442
Mystic/ACSS/TW 666.6 13 0.5236/0.5914 2 20 7 x 0.1111 0.3333 0.913 625.7 229.7 855.4 18200 19900 22900 0.1310 0.1619 798 980 1238 1431 1595
Oswego/ACSS/TW 664.8 16 0.5221/0.6072 2 20 7 x 0.1244 0.3732 0.927 624.6 288.0 912.6 21700 23400 27200 0.1309 0.1616 802 985 1244 1439 1604
Maumee/ACSS/TW 768.2 13 0.6034/0.6819 2 20 7 x 0.1195 0.3585 0.977 721.1 265.8 986.9 21000 23000 26500 0.1137 0.1407 872 1072 1356 1569 1750
Wabash/ACSS/TW 762.8 16 0.5992/0.6966 2 20 7 x 0.1331 0.3993 0.990 716.7 329.7 1046 24900 26800 31200 0.1141 0.1411 873 1074 1359 1573 1755
Kettle/ACSS/TW 957.2 7 0.7518/0.8038 3 32 7 x 0.0973 0.2919 1.060 901.6 176.2 1078 16800 18100 20400 0.0922 0.1180 973 1197 1514 1753 1955
Fraser/ACSS/TW 946.7 10 0.7436/0.8168 3 35 7 x 0.1154 0.3462 1.077 892.6 247.9 1141 21100 22900 26200 0.0930 0.1187 974 1199 1517 1756 1959
Columbia/ACSS/TW 966.2 13 0.7589/0.8573 2 21 7 x 0.1338 0.4014 1.092 906.9 333.2 1240 26400 28300 32800 0.0904 0.1124 1005 1239 1571 1822 2035
Suwannee/ACSS/TW 959.6 16 0.7537/0.8762 2 22 7 x 0.1493 0.4479 1.108 901.6 414.9 1317 30700 33100 38600 0.0907 0.1127 1008 1243 1576 1828 2042
Cheyenne/ACSS/TW 1168.1 5 0.9175/0.9646 3 30 7 x 0.0926 0.2778 1.155 1099 159.6 1259 17200 18300 20500 0.0757 0.0979 1095 1350 1712 1986 2219
Genesee/ACSS/TW 1158.0 7 0.9095/0.9733 3 33 7 x 0.1078 0.3234 1.165 1091 216.3 1307 20500 22100 25000 0.0762 0.0981 1094 1350 1712 1985 2218
Hudson/ACSS/TW 1158.4 13 0.9098/1.0281 2 25 7 x 0.1467 0.4401 1.196 1087 400.6 1488 31100 33500 38800 0.0754 0.0943 1124 1389 1766 2051 2295
Catawba/ACSS/TW 1272.0 5 0.9991/1.0505 3 30 7 x 0.0967 0.2901 1.203 1197 174.0 1371 18700 20000 22300 0.0695 0.0900 1152 1423 1807 2098 2346
Nelson/ACSS/TW 1257.1 7 0.9874/1.0557 3 35 7 x 0.1115 0.3345 1.213 1184 231.4 1415 22100 23800 26900 0.0702 0.0907 1150 1420 1804 2094 2342
Yukon/ACSS/TW 1233.6 13 0.9689/1.0925 3 38 19 x 0.0910 0.4550 1.245 1165 419.2 1584 33200 36300 41900 0.0712 0.0914 1154 1425 1810 2101 2350

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
418 Information on this sheet subject to change without notice.
20140925 Copyright © 2018, American Wire Group, Inc.
ACSS/TW

DISTRIBUTION CABLES
TRANSMISSION.&
Item # Size Type Cross Stranding Diameter Weight Rated Breaking Resistance Ampacity
KCMIL No. Sectional (in) (lb/MFT) Strength (lb) (ohm/mile) (amps)
Al/Total Layers No. x Dia./ St Complete Al St Total Standard High Ultra DC AC 75°C 100°C 150°C 200°C 250°C
(in)2 Wires St Wire Core Cable High 20°C 75°C
Truckee/ACSS/TW 1372.5 5 1.0780/1.1334 3 30 7 x 0.1004 0.3012 1.248 1292 187.6 1479 20200 21500 24000 0.0644 0.0838 1206 1491 1896 2203 2466
Mackenzie/ACSS/TW 1359.7 7 1.0679/1.1418 3 36 7 x 0.1159 0.3477 1.259 1281 250.0 1531 23900 25700 29000 0.0649 0.0842 1206 1490 1895 2202 2465
Thames/ACSS/TW 1334.6 13 1.0480/1.1809 3 39 19 x 0.0944 0.4720 1.290 1260 451.1 1711 35800 39100 45100 0.0658 0.0847 1210 1495 1902 2209 2472
St. Croix/ACSS/TW 1467.8 5 1.1529/1.2124 3 33 7 x 0.1041 0.3123 1.292 1381 201.7 1583 21600 23100 25800 0.0602 0.0787 1256 1554 1979 2302 2578
Miramichi/ACSS/TW 1455.3 7 1.1430/1.2222 3 36 7 x 0.1200 0.3600 1.302 1372 268.0 1640 25600 27100 30700 0.0607 0.0790 1269 1573 2007 2338 2577
Merrimack/ACSS/TW 1433.6 13 1.1250/1.2677 3 39 19 x 0.0978 0.4890 1.340 1356 434.0 1840 38400 42000 48400 0.0613 0.0791 1277 1584 2021 2354 2595
Platte/ACSS/TW 1569.0 5 1.2323/1.2957 3 33 7 x 0.1074 0.3222 1.334 1478 215.0 1693 23100 24600 27500 0.0564 0.0740 1319 1637 2092 2439 2692
Potomac/ACSS/TW 1557.4 7 1.2232/1.3079 3 36 7 x 0.1241 0.3723 1.345 1468 287.0 1755 27300 29000 32800 0.0567 0.0741 1321 1639 2094 2441 2694
Rio Grande/ACSS/TW 1533.3 13 1.2043/1.3571 3 39 19 x 0.1012 0.5060 1.382 1449 519.0 1968 41200 45000 51900 0.0573 0.0742 1329 1650 2108 2456 2710
Schuylkill/ACSS/TW 1657.4 7 1.3020/1.3920 3 36 7 x 0.1280 0.3840 1.386 1563 305.0 1868 29100 30900 34900 0.0533 0.0700 1370 1702 2177 2539 2805
Pecos/ACSS/TW 1622.0 13 1.2739/1.4429 3 39 19 x 0.1064 0.5320 1.424 1533 574.0 2107 45000 49300 56900 0.0541 0.0703 1377 1710 2187 2551 2816
Pee Dee/ACSS/TW 1758.6 7 1.3810/1.4770 3 37 7 x 0.1319 0.3957 1.427 1658 324.0 1982 30900 32800 37100 0.0502 0.0663 1418 1763 2259 2637 2916
James/ACSS/TW 1730.6 13 1.3590/1.5314 3 34 19 x 0.1075 0.5375 1.470 1636 585.0 2221 46400 50800 58500 0.0508 0.0663 1430 1778 2277 2657 2937
Athabaska/ACSS/TW 1949.6 7 1.5312/1.6377 3 44 7 x 0.1392 0.4176 1.504 1836 360.7 2197 34300 36500 41300 0.0453 0.0595 1505 1873 2403 2808 3157
Cumberland/ACSS/TW 1926.9 13 1.5134/1.7049 3 42 19 x 0.1133 0.5665 1.545 1819 649.8 2469 51600 56400 65000 0.0456 0.0600 1508 1875 2400 2802 3148
Powder/ACSS/TW 2153.8 8 1.6912/1.8290 4 64 19 x 0.0961 0.4805 1.602 2043 467.5 2510 42100 45500 51700 0.0412 0.0543 1599 1996 2569 3009 3391
Santee/ACSS/TW 2627.3 8 2.0630/2.2268 4 64 19 x 0.1062 0.5310 1.762 2492 570.9 3062 51300 55600 63100 0.0338 0.0459 1784 2237 2894 3403 3846

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 418
Copyright © 2018, American Wire Group, Inc. 20140925
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Solid Soft-Drawn
Bare Aluminum Tie Wire

DISTRIBUTION CABLES
TRANSMISSION.&
Application
To secure conductor to pin type insulators on a distribution line.

Construction
Bare aluminum EC grade solid conductor

Standards
ASTM B-230 Aluminum 1350-H19 Wire for electrical purposes

Packaging
25lb coil, 50lb coil, coil boxes, spool or as required

Item # Size Weight


/MFT
(lb)
ATW-6 6 24.2
ATW-4 4 38.2
ATW-2 2 61.1

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 408
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Covered AL Line Wire
Weatherproof

DISTRIBUTION CABLES
TRANSMISSION.&
Applications
Covered Line Wire is used primarily for overhead secondary distribution lines. It is not an electri-
cally insulated conductor and is treated as bare conductor when installed.

Construction
Conductors are aluminum alloy 1350-H19, 6201-181, or ACSR conductors, concentrically stranded
and covered for weather proofing with polyethylene, high density polyethylene (HD) or crosslinked
polyethylene (XLP).

Standards
• ASTM B-230 Aluminum 1350-H19 Wire for Electrical Purposes
• ASTM B-231 Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
• ASTM B-1248 Polyethylene Plastics Molding and Extrusion Materials.
• ASTM C-8.35 Specifications for Weather-Resistant Polethylene-Covered Wire and Cable.
• ICEA S-70-547
Notes
• The code words as given apply to conventional polyethylene line wire.
• For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum
equivalent.
• Ampacity ratings based on 75°C conductor temperature, 25°C ambient temperature elevation –
sea level. Emissivity 0.91 coefficient of absorption 0.95. Thermal reisitivity of covering -375°C-
Cm2/Watt-CM. Wind speed 2ft/sec in sun.
• To determine correct ampacity by conductor size, please consult the National Electric Code, latest
edition.

Item # Size Strand Insulation Outside Rated XLP Poly XLP


AWG or Thickness Diameter Breaking Weight Weight Ampacity
MCM (mil) (in) Strength /MFT /MFT
(lb) (lb) (lb)
AAC
Apple 6 Solid 30 .222 445 33.0 32.0 105
Pear 4 Solid 30 .264 675 48.5 47.3 135
Apricot 4 7/w 30 .285 790 51.5 50.8 140
Peach 2 7/w 45 .373 1220 87.1 84.0 180
Quince 1/0 7/w 60 .477 1790 140.7 135.6 240
Orange 2/0 7/w 60 .522 2260 171.9 166.2 280
Fig 3/0 7/w 60 .570 2740 210.5 204.0 320
Olive 4/0 7/w 60 .626 3450 258.7 251.4 370
Pomegranate 4/0 19/w 60 .632 3620 254.8 247.9 370
Mulberry 266.8 19/w 60 .692 4470 313.5 305.8 430
Anona 336.4 19/w 60 .766 5535 387.6 378.8 495
Molles 397.5 19/w 75 .852 6400 469.2 457.4 545
Huckleberry 477.0 37/w 75 .921 7820 550.0 537.5 610
Paw Paw 556.5 37/w 75 .982 8950 633.0 619.4 670
Breadfruit 636.0 61/w 95 1.080 10510 742.6 724.7 720
Persimmon 795.0 61/w 95 1.187 12900 910.0 890.0 825
Grapefruit 1033.5 61/w 95 1.327 16500 1156.7 1133.8 970

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 409
Copyright © 2018, American Wire Group, Inc. 20140902
Covered AL Line Wire
Weatherproof
DISTRIBUTION CABLES
TRANSMISSION &

Item # Size Strand Insulation Outside Rated XLP Poly XLP


AWG or Thickness Diameter Breaking Weight Weight Ampacity
MCM (mil) (in) Strength /MFT /MFT
(lb) (lb) (lb)
ACSR
Walnut 6 6/1 30 .258 1131 49 47 105
Butternut 4 6/1 30 .303 1170 71.8 70.0 135
Hickory 4 7/1 30 .309 2240 81.6 79.8 135
Pignut 2 6/1 45 .397 2710 118.1 114.8 180
Beech 2 7/1 45 .405 3460 134.1 130.7 180
Chestnut 1 6/1 45 .434 3370 145.5 141.8 210
Almond 1/0 6/1 60 .506 4160 190.4 184.9 235
Pecan 2/0 6/1 60 .554 5040 234.2 227.9 270
Filbert 3/0 6/1 60 .607 6290 288.5 281.4 305
Buckeye 4/0 6/1 60 .666 7930 356.5 348.5 345
Hackberry 266.8 18/1 60 .711 6540 354.8 346.8 435
6201-T81
Hornbeam 4 7/w 30 .310 1480 62.1 60.1 145
Linden 2 7/w 45 .406 2520 96.1 93.3 190
Oilnut 1/0 7/w 60 .518 4010 166.1 160.0 250
Waterash 2/0 7/w 60 .567 4850 203.3 196.4 290
Shellbark 3/0 7/w 60 .622 6110 249.4 241.4 335
Planetree 4/0 7/w 60 .683 7700 307.3 298.1 385

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
409 Information on this sheet subject to change without notice.
20140902 Copyright © 2018, American Wire Group, Inc.
Packaging Information
ACSR and ACSR/AW

DISTRIBUTION CABLES
TRANSMISSION.&
Code Size Stranding Standard Packages Code Size Stranding Standard Packages
Word Circular Length Weight Reel Word Circular Length Weight Reel
(ml or AWG) (ft) (lb) Size (ml or AWG) (ft) (lb) Size
Turkey 6 6/1 5,400 195 Coil Ibis 397500 26/7 13,890 7,590 RMT 84.36
16,340 590 NR 30.22 6,945 3,795 NR 60.28
Swan 4 6/1 3,835 220 Coil Lark 397500 30/7 7,980 4,970 RM 66.32
15,420 885 NR 36.22 7,980 4,970 NR 66.28
Swanate 4 7/1 3,580 240 Coil Pelican 477000 18/1 8,030 4,160 RM 66.32
17,910 1,200 NR 38.22 8,030 4,160 NR 66.28
8,955 600 NR 30.22 4,015 2,080 NR 48.28
Sparrow 2 6/1 2,410 220 Coil Flicker 477000 24/7 10,660 6,550 RMT 84.36
19,390 1,700 NR 42.28 5,330 3,275 NR 60.28
9,695 885 NR 36.22 Hawk 477000 26/7 11,570 7,590 RMT 84.36
6,465 590 NR 30.22 5,785 3,795 NR 60.28
Sparate 2 7/1 2,250 240 coji Hen 477000 30/7 6,650 4,970 RM 66.32
11,250 1,200 NR 38.22 6,650 4,970 NR 66.28
5,625 600 NR 30.22 Osprey 556500 18/1 6,890 4,160 RM 66.32
Robin 1 6/1 1,910 220 Coil 6,890 4,160 NR 66.28
15,380 1,770 NR 42.28 3,445 2,080 NR 48.28
7,690 885 NR 36.22 Parakeet 556500 24/7 9,140 6,550 RMT 84.36
5,125 590 NR 30.22 4,570 3,275 NR 60.28
Raven 1/0 6/1 1,515 220 Coil Dove 556500 26/7 9,910 7,590 RMT 84.36
12,180 1,770 NR 42.28 4,955 3,795 NR 60.28
6,090 885 NR 36.22 Eagle 556500 30/7 5,700 4,970 RM 66.32
4,060 590 NR 30.22 5,700 4,970 NR 66.28
Quail 210 6/1 9,660 1,770 NR 42.28 Peacock 605000 24/7 8,400 6,550 RMT 84.36
4,830 885 NR 36.22 4,200 3,275 NR 60.28
3,220 590 NR 30.22 Squab 605000 26/7 9,120 7,590 RMT 84.36
Pigeon 3/0 6/1 7,670 1,770 NR 42.28 4,560 3,795 NR 60.28
3,835 885 NR 36.22 Teal 605000 30/19 10,490 9,860 RMT 84.45
2,555 590 NR 30.22 5,245 4,930 RM 66.32
Penguin 4/0 6/1 6,080 1,770 NR 42.28 5,245 4,930 NR 66.28
3,040 885 NR 36.22 Swift 636000 36/1 6,025 3,880 RM 66.32
2,025 590 NR 30.22 6,025 3,880 NR 66.28
Waxwing 266800 18/1 14,370 4,160 NR 66.28 4,015 2,585 NR 60.28
7,185 2,080 NR 48.28 Kingbird 636000 18/1 6,020 4,160 RM 66.32
Owl 266800 6/7 4,555 1,560 NR 42.28 6,020 4,160 NR 66.28
Partridge 266800 26/7 10,330 3,795 NR 60.28 4,515 3,120 NR 60.28
Merlin 336400 18/1 11,390 4,160 NR 66.28 3,010 2,080 NR 48.28
5,695 2,080 NR 48.28 Rook 636000 24/7 8,000 6,550 RMT 84.36
Linnet 336400 26/7 16,410 7,590 RMT 84.36 4,000 3,275 NR 60.28
8,205 3,795 NR 60.28 Grosbeak 636000 26/7 8,670 7,590 RMT 84.36
Oriole 336400 30/7 9,430 4,970 RM 66.32 4,335 3,795 NR 60.28
9,430 4,970 NR 66.28 Egret 636000 30/19 9,980 9,860 RMT 84.45
Chickadee 397500 18/1 9,640 4,160 RM 66.32 4,990 4,930 RM 66.32
9,640 4,160 NR 66.28 4,990 4,930 RM 66.28
4,820 2,080 NR 48.28
Brant 397500 24/7 12,790 6,550 RMT 84.36
6,395 3,275 NR 60.28

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 410
Copyright © 2018, American Wire Group, Inc. 20140921
Packaging Information
ACSR and ACSR/AW
DISTRIBUTION CABLES
TRANSMISSION &

Code Size Stranding Standard Packages Code Size Stranding Standard Packages
Word Circular Length Weight Reel Word Circular Length Weight Reel
(ml or AWG) (ft) (lb) Size (ml or AWG) (ft) (lb) Size
Flamingo 666600 24/7 11,440 9,830 RMT 84.45 Bluejay 1113000 45/7 12,850 16,125 RMT 96.60
7,630 6,550 RMT 84.36 8,570 10,750 RMT 90.45
3,815 3,275 NR 60.28 4,285 5,375 RM 68.38
Gannet 666600 26/7 12,410 11,380 RMT 90.45 2,855 3,585 NR 60.28
8,270 7,590 RMT 84.36 Finch 1113000 54/19 8,190 11,720 RMT 90.45
4,135 3,795 NR 60.28 4,095 5,860 RM 68.38
Starling 715500 26/7 11,560 11,380 RMT 90.45 Bunting 1192500 45/7 12,000 16,125 RMT 96.60
7,710 7,590 RMT 84.36 8,000 10,750 RMT 90.45
3,855 3,795 NR 66.28 4,000 5,375 RM 68.38
Redwing 715500 30/19 8,880 9,860 RMT 84.45 Grackle 1192500 54/19 7,650 11,720 RMT 90.45
4,440 4,930 RM 66.32 3,825 5,860 RM 68.38
4,440 4,930 NR 66.28 Bittern 1272000 45/7 11,245 16,125 RMT 96.60
Coot 795000 36/1 9,640 7,760 RMT 84.45 7,500 10,750 RMT90.45
4,820 3,880 RM 66.32 3,750 5,375 RM 68.38
4,820 3,880 NR 66.28 Pheasant 1272000 54/19 7,170 11,720 RMT 90.45
Tern 795000 45/7 12,000 10,750 RMT 90.45 3,585 5,860 RM 68.38
6,000 5,375 RM 68.38 Dipper 1351500 45/7 10,585 16,125 RMT 96.60
4,000 3,585 NR 60,28 7,060 10,750 RMT 90.45
Cuckoo 795000 24/7 9,600 9,830 RMT 90.45 3,530 5,375 RM 68.38
6,400 6,550 RMT 84.36 Martin 1351500 54/19 6,750 11,720 RMT 90.45
3,200 3,275 NR 60.28 3,375 5,860 RM 68.38
Condor 795000 54/7 11,520 11,800 RMT 90.45 Bobolink 1431000 45/7 10,000 16,125 RMT 96.60
5,760 5,900 RM 68.38 6,660 10,750 RMT 90.45
Drake 795000 26/7 10,400 11,380 RMT 90.45 3,335 5,375 RM 68.38
6,940 7,590 RMT 84.36 Plover 1431000 54/19 6,370 11,720 RMT 90.45
3,470 3,795 NR 60.28 3,185 5,860 RM 68.38
Mallard 795000 30/19 7,980 9,860 RMT 84.45 Nuthatch 1510500 45/7 9,470 16,125 RMT 96.60
3,990 4,930 RM 66.32 6,310 10,750 RMT 90.45
3,990 4,930 NR 66.28 3,155 5,375 RM 68.38
Ruddy 900000 45/7 10,590 10,750 RMT 90.45 Parrot 1510500 54/19 6,040 11,720 RMT 90.45
5,295 5,375 RM 68.38 3,020 5,860 RM 68.38
Canary 900000 54/7 10,180 11,800 RMT 90.45 Lapwing 1590000 45/7 9,000 16,125 RMT 96.60
5,090 5,900 RM 68.38 6,000 10,750 RMT 90.45
Catbird 954000 36/1 8,030 7,760 RMT 84.45 3,000 5,375 RM 68.38
4,015 3,880 RM 66.32 Falcon 1590000 54/19 5,730 11,720 RMT 90.45
4,015 3,880 NR 66.28 2,865 5,860 RM 68.38
Rail 954000 45/7 14,990 16,125 RMT 96.60 Chukar 1780000 84/19 9,200 19,080 RMT 96.60
9,990 10,750 RMT 90.45 Bluebird 2156000 84/19 7,500 18,830 RMT 96.60
4,995 5,375 RM 68.38 Kiwi 2167000 72/7 7,000 16,120 RMT 96.60
Cardinal 954000 54/7 9,600 11,800 RMT 90.45 Thrasher 2312000 76/19 9,500 24,000 RMT 108.74
4,800 5,900 RM 68.38 6,940 17,530 RMT 96.60
Ortolan 1033500 45/7 13,850 16,125 RMT 96.60 Joree 2515000 76/19 8,730 24,000 RMT 108.74
9,230 10,750 RW90.45
4,615 5,375 RM 68.38
Curlew 1033500 54/7 8,870 11,800 RMT 90.45
4,435 5,900 RM 68.38

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
410 Information on this sheet subject to change without notice.
20140921 Copyright © 2018, American Wire Group, Inc.
Packaging Information
ACSR and ACSR/AW

DISTRIBUTION CABLES
TRANSMISSION.&
Code Size Stranding Standard Packages
Word Circular Length Weight Reel
(ml or AWG) (ft) (lb) Size
Petrel 101800 12/7 12,500 3,175 NR 48.28
Minorca 110800 12/7 11,480 3,175 NR 48.28
Leghorn 134600 12/7 9,450 3,175 NR 48.28
Guinea 159000 12/7 8,000 3,175 NR 48.28
Dotterel 176900 12/7 7,195 3,175 NR 48.28
Dorking 190800 12/7 6,665 3,175 NR 48.28
Brahma 203200 16/19 7,875 5,330 NR 60.28
Cochin 211300 12/7 6,020 3,175 NR 48.28

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 410
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Packaging Information
AAC

DISTRIBUTION CABLES
TRANSMISSION.&
Code Size Stranding Standard Packages Code Size Stranding Standard Packages
Word Circular Length Weight Reel Word Circular Length Weight Reel
(ml or AWG) (ft) (lb) Size (ml or AWG) (ft) (lb) Size
Peachbell 6 7 56,910 1,400 NR 42.28 Daffodil 350000 19 11,560 3,800 RM 66.32
28,455 700 NR 36.22 11,560 3,800 NR 66.28
8,130 200 Coil 5,780 1,900 NR 48.28
Rose 4 7 35,710 1,400 NR 42.28 Canna 397500 19 10,180 3,800 RM 66.32
17,855 700 NR 36.22 10,180 3,800 NR 66.28
5,100 200 Coil 5,090 1,900 NR 48.28
Iris 2 7 22,470 1,400 NR 42.28 Golden Tuft 450000 19 9,000 3,800 RM 66.32
11,235 700 NR 36.22 9,000 3,800 NR 66.28
3,210 200 Coil 4,500 1,900 NR 48.28
Pansy 1 7 17,830 1,400 NR 42.28 Cosmos 477000 19 8,490 3,800 RM 66.32
8,915 700 NR 36.22 8,490 3,800 NR 66.28
2,550 200 Coil 4,245 1,900 NR 48.28
Poppy 1/0 7 14,130 1,400 NR 42.28 Syringa 477000 37 16,530 7,400 RMT 84.45
7,065 700 NR 36.22 8,265 3,700 NR 66.32
2,020 200 Coil 8,265 3,700 NR 66.28
Aster 2/0 7 11,210 1,400 NR 42.28 Zinnia 500000 19 8,100 3,800 RM 66.32
5,605 700 NR 36.22 8,100 3,800 NR 66.28
Phlox 3/0 7 8,890 1,400 NR 42.28 4,050 1,900 NR 48.28
4,445 700 NR 36.22 Hyacinth 500000 37 15,760 7,400 RMT 84.45
Oxlip 4/0 7 7,050 1,400 NR 42.28 7,880 3,700 RM 66.32
3,525 700 NR 36.22 7,880 3,700 NR 66.28
Sneezewort 250000 7 5,970 1,400 NR 42.28 Dahlia 556500 19 7,270 3,800 RM 66.32
2,985 700 NR 36.22 7,270 3,800 NR 66.28
Valerian 250000 19 16,190 3,800 RM 66.32 3,635 1,900 NR 48.28
16,190 3,800 NR 66.28 Mistletoe 556500 37 14,170 7,400 RMT 84.45
8,095 1,900 NR 48.28 7,085 3,700 RM 66.32
Daisy 266800 7 5,590 1,400 NR 42.28 7,085 3,700 NR 66.28
2,795 700 NR 36.22 Meadowsweet 600000 37 13,140 7,400 RMT 84.45
Laurel 266800 19 15,170 3,800 RM 66.32 6,570 3,700 RM 66.32
15,170 3,800 NR 66.28 6,570 3,700 NR 66.28
7,585 1,900 NR 48.28 Orchid 636000 37 12,400 7,400 RMT 84.45
Peony 300000 19 13,490 3,800 RM 66.32 6,200 3,700 RM 66.32
13,490 3,800 NR 66.28 6,200 3,700 NR 66.28
6,745 1,900 NR 48.28 Heuchera 650000 37 12,130 7,400 RMT 84.45
Tulip 336400 19 12,030 3,800 RM 66.32 6,065 3,700 RM 66.32
12,030 3,800 NR 66.28 6,065 3,700 NR 66.28
6,015 1,900 NR 48.28

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 411
Copyright © 2018, American Wire Group, Inc. 20140921
Packaging Information
AAC
DISTRIBUTION CABLES
TRANSMISSION &

Code Size Stranding Standard Packages Code Size Stranding Standard Packages
Word Circular Length Weight Reel Word Circular Length Weight Reel
(mil) or AWG) (ft) (lb) Size (mil) or AWG) (ft) (lb) Size
Verbena 700000 37 11,260 7,400 RMT 84.45 Hawkweed 1000000 37 7,880 7,400 RMT 84.45
5,630 3,700 RM 66.32 3,940 3,700 RM 66.32
5,630 3,700 NR 66.28 3,940 3,700 NR 66.28
2,815 1,850 NR 48.28 Camellia 1000000 61 10,400 9,760 RMT 90.45
Flag 700000 61 14,850 9,760 RMT 90.45 5,200 4,880 NR 68.38
7,425 4,800 RM 68.38 Bluebell 1033500 37 7,630 7,400 RMT 84.45
Violet 715500 37 11,020 7,400 RMT 84.45 3,815 3,700 RM 66.32
5,510 3,700 RM 66.32 3,815 3,700 NR 66.28
5,510 3,700 NR 66.28 Larkspur 1033500 61 10,060 9,760 RMT 90.45
2,755 1,850 NR 48.28 5,030 4,880 RM 68.38
Nasturtium 715500 61 14,530 9,760 RMT 90.45 Marigold 1113000 61 9,430 9,760 RMT 90.45
7,265 4,800 RM 68.38 4,670 4,880 RM 68.38
Petunia 750000 37 10,510 7,400 RMT 84.45 Hawthorn 1192500 61 8,720 9,760 RMT 90.45
5,255 3,700 RM 66.32 4,360 4,880 RM 68.38
5,255 3,700 NR 66.28 Narcissus 1272000 61 8,170 9,760 RMT 90.45
Cattail 750000 61 13,860 9,760 RMT 90.45 4,085 4,880 RM 68.38
6,930 4,880 NR 68.38 Columbine 1351500 61 7,690 9,760 RMT 90.45
Arbutus 795000 37 9,920 7,400 RMT 84.45 3,845 4,880 RM 68.38
4,960 3,700 RM 66.32 Carnation 1431000 61 7,270 9,760 RMT 90.45
4,960 3,700 NR 66.28 3,635 4,880 RM 68.38
2,480 1,850 NR 48.28 Gladiolus 1510500 61 6,880 9,760 RMT90.45
Lilac 795000 61 13,080 9,760 RMT 90.45 3,440 4,880 RM 68.38
6,540 4,880 RM 68.38 Coreopsis 1590000 61 6,540 9,760 RMT90.45
Cockscomb 900000 37 8,760 7,400 RMT 84.45 3,270 4,880 RM 68.38
4,380 3,700 RM 66.32 Jassamine 1750000 61 5,940 9,760 RMT 90.45
4,380 3,700 NR 66.28 Cowslip 2000000 91 4,850 9,100 RMT 90.45
Snapdragon 900000 61 11,550 9,760 RMT 90.45 Sagebrush 2250000 91 4,270 9,100 RMT 90.45
5,775 4,880 RM 68.38 Lupine 2500000 91 3,840 9,100 RMT 90.45
Magnolia 954000 37 8,260 7,400 RMT 84.45 Bitterroot 2750000 91 3,490 9,100 RMT 90.45
4,130 3,700 RM 66.32 Trillium 3000000 127 3,350 9,530 RMT 90.45
4,130 3,700 NR 66.28 Bluebonnet 3500000 127 2,840 9,530 RMT 90.45
Goldenrod 954000 61 10,900 9,760 RMT 90.45
5,450 4,880 RM 68.38

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
411 Information on this sheet subject to change without notice.
20140921 Copyright © 2018, American Wire Group, Inc.
Packaging Information
AAAC 6201 Alloy

DISTRIBUTION CABLES
TRANSMISSION.&
Code Approx EC Size Standard Packages Code Approx EC Size Standard Packages
Word Cond. with Circular Length Weight Reel Word Cond. with Circular Length Weight Reel
Equivalent (mil) (ft) (lb) Size Equivalent (mil) (ft) (lb) Size
Resistance Resistance
Akron 6 30580 48,780 1,400 NR 42.28 Canton 336.4 394500 10,260 3,800 RM 66.32
24,390 700 NR 36.22 10,260 3,800 NR 66.28
6,970 200 Coil 5,130 1,900 NR 48.28
Alton 4 48690 30,630 1,400 NR 42.28 3,420 1,265 NR 42.28
15,315 700 NR 36.22 Cairo 397.5 465400 8,700 3,800 RM 66.32
4,375 200 Coil 8,700 3,800 NR 66.28
Ames 2 77470 19,260 1,400 NR 42.28 4,350 1,900 NR 48.28
9,630 700 NR 36.22 2,900 1,265 NR 42.28
2,750 200 Coil Darien 477.0 559500 7,240 3,800 RM 66.32
Azusa 1/0 123300 12,100 1,400 NR 42.28 7,240 3,800 NR 66.28
6,050 700 NR 36.22 3,620 1,900 NR 48.28
1,730 200 Coil 2,415 1,265 NR 42.28
Anaheim 2/0 155400 9,600 1,400 NR 42.28 Elgin 556.5 652400 6,210 3,800 RM 66.32
4,800 700 NR 36.22 6,210 3,800 NR 66.28
Amherst 3/0 195700 7,600 1,400 NR 42.28 3,105 1,900 NR 48.28
3,810 700 NR 36.22 2,070 1,265 NR 42.28
Alliance 4/0 246900 6,040 1,400 NR 42.28 Flint 636.0 740800 10,640 7,400 RMT 84.45
3,020 700 NR 36.22 5,320 3,700 RM 66.32
Butte 266.8 312800 12,940 3,800 RM 66.32 5,320 3,700 NR 66.28
12,940 3,800 NR 66.28 2,660 1,850 NR 48.28
6,470 1,900 NR 48.28 Greeley 795.0 927200 8,500 7,400 RMT 84.45
4,315 1,265 NR 42.28 4,250 3,700 RM 66.32
Note 4,250 3,700 NR 66.28
Length Tolerances: Standard lengths shown in these data are nominal. The 2,125 1,850 NR 48.28
allowable tolerance shall be plus or minus 5% for sizes larger than 77470
kcmil.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
8Information on this sheet subject to change without notice. 412
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Packaging Information:
TP Twisted Pair

DISTRIBUTION CABLES
TRANSMISSION.&
Bare Aluminum Cable ACSR Bare Aluminum Cable ACSR
ACSR/TP ACSR/TP
Code Size Standard Packages Code Size Standard Packages
Word Circular Length Weight Reel Word Circular Length Weight Reel
(ml or AWG) (ft) (lb) Size (ml or AWG) (ft) (lb) Size
Swallow TP 2x#3-6/1 12205 1770 48.28 NR Ptarmigan TP 2x397.5-20/7 5400 4780 84.36 RMT
24410 3540 60.28 NR 10800 9570 90.45 RMT
Sparrow TP 2x#2-6/1 9650 1770 48.28 NR lbis TP 2x397.5-26/7 6925 7590 84.45 RMT
19390 3540 60.28NR 13850 15180 96.60 RMT
Robin TP 2x#1-6/1 7685 1770 48.28 NR Pelican TP 2x477.0-18/1 4000 4160 68.38 RM
15370 3540 60.28 NR 8000 8320 90.45 RMT
Raven TP 2xl/0-6/1 6050 1770 48.28 NR Tatler TP 2x477.0-20/7 4450 4780 66.38 RM
12100 3540 60.28 NR 8900 9570 90.45 RMT
Quail TP 2x2/0-6/1 4825 1770 48.28 NR Flicker TP 2x477.0-24/7 5330 6550 84.45 RMT
9650 3540 60.28 NR 10660 13100 96.60 RMT
Pigeon TP 2x3/0-6/1 3825 1770 48.28 NR Hawk TP 2x477.0-26/7 5750 7590 84.45 RMT
7650 3540 60.28 NR 11500 15180 96.60 RMT
Penguin TP 2x4/0-6/1 3025 1770 48.28 NR Creeper TP 2x517.0-18/1 3710 4160 68.38 RM
6050 3540 66.28 NR 7420 8320 94.45 RMT
Waxwing TP 2x266.6-18/1 5375 3115 66.28NR Osprey TP 2x556.5-18/1 3425 4160 68.38 RM
7180 4180 68.38 NR 6850 8320 90.45 RMT
14360 8320 90.45 RMT Parakeet TP 2x556.5-24/7 4570 6550 68.38 RM
Partridge TP 2x266.8-26/7 5150 3795 66.28 NR 9140 13100 90.45 RMT
10300 7590 90.45 RMT Dove TP 2x556.5-26/7 4950 7590 90.45 RMT
Merlin TP 2x336.4-18/1 3775 2770 66.28 NR 9900 15180 95.60 RMT
5650 4180 68.38 NR Rook TP 2x636.0-24/7 8000 13100 96.60 RMT
11300 8320 90.45 RMT Drake TP 2x795.0-26/7 3450 7590 84.45 RMT
Linnet TP 2x336.4-26/7 4050 3785 66.28 NR 6900 15180 96.60 RMT
8100 7595 90.45 RMT Tern TP 2x795.0-45/7 4000 7170 90.45 RMT
16200 15180 96.60 RMT 6000 10750 96.60 RMT
Chickadee TP 2x397.5-18/1 4800 4160 68.38 RM Bluejay TP 2x1113.0-45/7 5650 14180 96.60 RMT
9600 8320 90.45 RMT

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 413
Copyright © 2018, American Wire Group, Inc. 20140921
Packaging Information:
TP Twisted Pair
DISTRIBUTION CABLES
TRANSMISSION &

Bare Aluminum Cable AAC Bare Aluminum Cable AAC


AAC/TP AAAC Alloy 3201/TP
Code Size Standard Packages Code Size Standard Packages
Word Circular Length Weight Reel Word Circular Length Weight Reel
(ml or AWG) (ft) (lb) Size (ml or AWG) (ft) (lb) Size
Lily TP 2x#3-7 7090 700 42.24 NR Ames TP 2x#2-7 9,700 1,410 48.28 NR
14180 1400 48.48 NR 19,400 3,540 60.28 NR
28360 2800 60.28 NR Azusa TP 2x1/0-7 6,050 1,400 48.28 NR
Iris TP 2x#2-7 11250 1400 48.28 NR 12,100 2,822 60.28 NR
21000 2615 60.28 NR Anaheim TP 2x2/0-7 4,800 1,400 48.28 NR
Pansy TP 2x#1-7 8915 1400 48.28 NR 9,600 2,800 66.28 NR
17830 2800 66.28 NR Amherst TP 2x3/0 -7 3,810 1,400 48.28 NR
Poppy TP 2xl/0-7 7050 1400 48.28 NR 7,625 2,800 66.28 NR
14100 2800 66.28 NR Alliance TP 2x4/0-7 3,020 1,400 48.28 NR
Aster TP 2x2/0-7 5600 1400 48.28 NR 6,040 2,800 66.28 NR
11200 2800 66.28 NR Butte TP 2x266.8-19 6,475 3,800 66.28 NR
Phlox TP 2x3/0-7 4450 1400 48.28 NR
9900 2800 66.28 NR
Oxlip TP 2x4/0-7 3550 1400 48.28 NR
7100 2800 66.28 NR
Valerian TP 2x250.0-19 6800 3190 66.28 NR
16000 7510 84.36 RMT
Tulip TP 2x336.4-19 5300 3285 66.28 NR
6010 3800 68.38 NR
12020 7600 84.36 RMT
Canna TP 2x397.5-19 4400 3280 66.28 NR
5090 3800 68.36 NR
10180 7600 84.36 RMT
Cosmos TP 2x477.0-19 3600 3225 66.28 NR
4245 3800 68.38 NR
8490 7600 90.45 NR
Dahlia TP 2x556.5-19 3125 3265 66.28 NR
3635 3800 68.38 NR
7250 7600 90.45 RMT

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
413 Information on this sheet subject to change without notice.
20140921 Copyright © 2018, American Wire Group, Inc.
Packaging Information
Covered Line Wire

DISTRIBUTION CABLES
TRANSMISSION.&
AAC ACSR
Code Aluminum Conductors Standard Packages Code Aluminum Conductors Standard Packages
Word Size Stranding Length Poly XLP Reel Word Size Stranding Length Poly XLP Reel
AWG (ft) Weight Weight Size AWG or (ft) Weight Weight Size
(lb) (lb) Cmils (lb) (lb)
Pear 4 1 2,600 123 126 Coil Butternut 4 611 1,700 119 122 Coil
8,500 402 41 NRC 30.18 5,100 357 366 NRC 30.18
Hickory 4 7/1 1,500 120 122 Coil
6,000 479 490 NRC 30.18
AAC 1350-H19 Stranded Pignut 2 6/1 1,200 138 142 Coil
Code Aluminum Conductors Standard Packages 6,400 735 756 NRC 36.24
Word Size Stranding Length Poly XLP Reel
AWG or (ft) Weight Weight Size Beech 2 7/1 1,100 144 148 Coil
Cmils (lb) (lb) 5,600 732 751 NRC 36.24
Apricot 4 7 2,500 127 129 Coil Chestnut 1 6/1 1,000 142 146 Coil
7,000 356 361 NRC 30.18 5,100 723 742 NRC 36.24
Peach 2 7 1,500 126 131 Coil Almond 1/0 6/1 1,000 185 190 Coil
7,500 630 653 NRC 36.24 4,000 740 762 NRC 36.24
Quince 1/0 7 1,000 136 141 Coil Pecan 210 6/1 3,200 729 749 NRC 36.24
4,700 637 661 NRC 36.24 Filbert 3/0 6/1 3,800 1,069 1,096 NRC 40.24
Orange 210 7 3,750 623 645 NRC 36.24 Buckeye 410 6/1 3,000 1,046 1,070 NRC 40.24
Fig 3/0 7 4,400 898 926 NRC 40.24 Hackberry 266800 18/1 2,400 832 852 NRC 40.24
Olive 4/0 7 3,500 880 905 NRC 40.24
Pomegranate 4/0 19 3,800 942 968 NRC 40.24
AAAC Alloy 6201-T81
Mulberry 266800 19 3,000 917 941 NRC 40.24
Code Aluminum Conductors Standard Packages
Anona 336400 19 2,400 909 930 NRC 40.24 Word Size Stranding Length Poly XLP Reel
Molles 397500 19 2,000 915 938 NRC 40.24 AWG or (ft) Weight Weight Size
Huckleberry 477000 37 3,300 1,774 1,815 NRC 50.32 Cmils (lb) (lb)
Paw Paw 556500 37 2,800 1,463 1,772 NRC 50.32 Hornbeam 48690 7 1,700 102 106 Coil
Breadfruit 636000 61 2,500 1,812 1,857 NRC 50.32 5,100 307 317 NRC 30.18
Persimmon 795000 61 2,200 1,958 2,002 NRC 50.32 Linden 77470 7 1,200 112 115 Coil
Grapefruit 1033500 61 1,700 1,927 1,966 NRC 50.32 6,400 597 615 NRC 36.24
Oilnut 123300 7 1,000 160 166 Coil
4,000 640 664 NRC 36.24
Waterash 155400 7 3,200 628 651 NRC 36.24
Shellbark 195700 7 3,800 917 948 NRC 40.24
Planetree 246900 71 3,000 894 922 NRC 40.24

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 414
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
AAC
2 Layer 15kV

DISTRIBUTION CABLES
TRANSMISSION.&
Application • ASTM B230 Standard Specification for Alu-
Used for primary and secondary overhead dis- minum 1350–H19 Wire for Electrical Purposes
tribution where limited space is available or de- • ASTM B231 Standard Specification for Con-
sirable for rights of way. Installed as an centric-Lay-Stranded Aluminum 1350 Conduc-
uninsulated conductor; however, covering is ef- tors
fective in preventing direct shorts and instanta- • ASTM B232 Standard Specification for Con-
neous flashovers should tree limbs or other centric-Lay-Stranded Aluminum Conductors,
objects contact conductors in such close prox- Coated-Steel Reinforced (ACSR)
imity. The resulting close-proximity configura- • ASTM B398 Standard Specification for Alu-
tion minimizes the amount of space and minum-Alloy 6201-T81 and 6201-T83 Wire for
hardware required for line installation; particu- Electrical Purposes
larly useful in congested areas such as alley- • ASTM B399 Standard Specification for Con-
ways or tight corridors. centric-Lay-Stranded Aluminum-Alloy 6201-
T81 Conductors
Construction • ASTM B400 Standard Specification for Com-
Conductors are concentric strand AAC (1350- pact Round Concentric-Lay-Stranded Conduc-
H19), AAAC (either compressed or full compact tors
depending on conductor size) or ACSR. The con- • ASTM D2656 Standard Specification for
ductor shield shall be an extruded back semi- Cross-linked Polyethylene Insulation for Wire
conductor polymer meeting the physical and Cable Rated 2001 to 35 000 V
requirements of ICEA S-61-402. Available with • ASTM D1248 Standard Specification for Poly-
track-resistant high-density polyethylene (TR- ethylene Plastics Extrusion Materials for Wire
HDPE) per ASTM D1248 or Track-Resistant and Cable
Cross-linked Polyethylene (XLPE) covering per • ICEA S-70-547 Standard Specification for
ASTM D2656. The minimum thickness of each Weather Resistant Polyethylene Covered Con-
layer at any point shall not be less than listed in ductors
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to Notes
provide the weather resistance, and track resist- Full hardware solution is available, including
ance. spacers, brackets, installation tools and hard-
ware. Please consult with AWG for more infor-
Specification mation.
15kV - 35kV Covered Aerial Medium Voltage
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifica-
tions:

Item # Size Stranding Conductor Covering Covering Cable Rated Weight


AWG or Diameter Thickness Thickness O.D. Strength (lb/MFT)
kcmil (mil) Inner Outer (mil) (lb)
Layer Layer
(mil) (mil)
TW15-2-AAC-1/0-7 1/0 7 336 75 75 636 1791 196
TW15-2-AAC-2/0-7 2/0 7 376 75 75 676 2259 230
TW15-2-AAC-3/0-7 3/0 7 423 75 75 723 2736 272
TW15-2-AAC-4/0-7 4/0 7 475 75 75 775 3447 325
TW15-2-AAC-266.8-19 266.8 19 537 75 75 837 4473 387
TW15-2-AAC-336.4-19 336.4 19 603 75 75 903 5535 466
TW15-2-AAC-397.5-19 397.5 19 659 75 75 959 6399 535
TW15-2-AAC-477-19 477 19 722 75 75 1022 7524 623
TW15-2-AAC-556.5-37 556.5 37 780 75 75 1080 8946 708
TW15-2-AAC-636-37 636 37 835 75 75 1135 10260 794

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 420
Copyright © 2018, American Wire Group, Inc. 20160208
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
AAC
3 Layer 15kV-35kV

DISTRIBUTION CABLES
TRANSMISSION.&
Application • ASTM B230 Standard Specification for Alu-
Used for primary and secondary overhead dis- minum 1350–H19 Wire for Electrical Purposes
tribution where limited space is available or de- • ASTM B231 Standard Specification for Con-
sirable for rights of way. Installed as an centric-Lay-Stranded Aluminum 1350 Conduc-
uninsulated conductor; however, covering is ef- tors
fective in preventing direct shorts and instanta- • ASTM B232 Standard Specification for Con-
neous flashovers should tree limbs or other centric-Lay-Stranded Aluminum Conductors,
objects contact conductors in such close prox- Coated-Steel Reinforced (ACSR)
imity. The resulting close-proximity configura- • ASTM B398 Standard Specification for Alu-
tion minimizes the amount of space and minum-Alloy 6201-T81 and 6201-T83 Wire for
hardware required for line installation; particu- Electrical Purposes
larly useful in congested areas such as alley- • ASTM B399 Standard Specification for Con-
ways or tight corridors. centric-Lay-Stranded Aluminum-Alloy 6201-
T81 Conductors
Construction • ASTM B400 Standard Specification for Com-
Conductors are concentric strand AAC (1350- pact Round Concentric-Lay-Stranded Conduc-
H19), AAAC (either compressed or full compact tors
depending on conductor size) or ACSR. The con- • ASTM D2656 Standard Specification for
ductor shield shall be an extruded back semi- Cross-linked Polyethylene Insulation for Wire
conductor polymer meeting the physical and Cable Rated 2001 to 35 000 V
requirements of ICEA S-61-402. Available with • ASTM D1248 Standard Specification for Poly-
track-resistant high-density polyethylene (TR- ethylene Plastics Extrusion Materials for Wire
HDPE) per ASTM D1248 or Track-Resistant and Cable
Cross-linked Polyethylene (XLPE) covering per • ICEA S-70-547 Standard Specification for
ASTM D2656. The minimum thickness of each Weather Resistant Polyethylene Covered Con-
layer at any point shall not be less than listed in ductors
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to Notes
provide the weather resistance, and track resist- Full hardware solution is available, including
ance. spacers, brackets, installation tools and hard-
ware. Please consult with AWG for more infor-
Specification mation.
15kV - 35kV Covered Aerial Medium Voltage
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifica-
tions:

Item # Size Stranding Conductor Covering Covering Covering Cable Rated Weight
AWG or Diameter Thickness Thickness Thickness O.D. Strength (lb/MFT)
kcmil (mil) Conductor Inner Outer (mil) (lb)
Shield Layer Layer
(mil) (mil) (mil)
15kV
TW15-3-AAC-1/0-7 1/0 7 336 15 75 75 666 1791 210
TW15-3-AAC-2/0-7 2/0 7 376 15 75 75 706 2259 246
TW15-3-AAC-3/0-7 3/0 7 423 15 75 75 753 2736 289
TW15-3-AAC-4/0-7 4/0 7 475 15 75 75 805 3447 343
TW15-3-AAC-266.8-19 266.8 19 537 15 75 75 867 4473 407
TW15-3-AAC-336.4-19 336.4 19 603 15 75 75 933 5535 487
TW15-3-AAC-397.5-19 397.5 19 659 15 75 75 989 6399 558
TW15-3-AAC-477-19 477 19 722 15 75 75 1052 7524 648
TW15-3-AAC-556.5-37 556.5 37 780 20 75 75 1120 8946 742
TW15-3-AAC-636-37 636 37 835 20 80 80 1195 10260 846
TW15-3-AAC-795-37 795 37 932 20 80 80 1292 12510 1020

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 421
Copyright © 2018, American Wire Group, Inc. 20160208
AAC
3 Layer 15kV-35kV
DISTRIBUTION CABLES
TRANSMISSION &

Item # Size Stranding Conductor Covering Covering Covering Cable Rated Weight
AWG or Diameter Thickness Thickness Thickness O.D. Strength (lb/MFT)
kcmil (mil) Conductor Inner Outer (mil) (lb)
Shield Layer Layer
(mil) (mil) (mil)
25kV
TW25-3-AAC-1/0-7 1/0 7 336 15 125 125 866 1791 309
TW25-3-AAC-2/0-7 2/0 7 376 15 125 125 906 2259 350
TW25-3-AAC-3/0-7 3/0 7 423 15 125 125 953 2736 400
TW25-3-AAC-4/0-7 4/0 7 475 15 125 125 1005 3447 460
TW25-3-AAC-266.8-19 266.8 19 537 15 125 125 1067 4473 531
TW25-3-AAC-336.4-19 336.4 19 603 15 125 125 1133 5535 621
TW25-3-AAC-397.5-19 397.5 19 659 15 125 125 1189 6399 698
TW25-3-AAC-477-19 477 19 722 20 125 125 1262 7524 806
TW25-3-AAC-556.5-37 556.5 37 780 20 125 125 1320 8946 899
TW25-3-AAC-636-37 636 37 835 20 125 125 1375 10260 995
TW25-3-AAC-795-37 795 37 932 20 125 125 1472 12510 1181
35kV
TW35-3-AAC-1/0-7 1/0 7 336 15 175 125 966 1791 368
TW35-3-AAC-2/0-7 2/0 7 376 15 175 125 1006 2259 411
TW35-3-AAC-3/0-7 3/0 7 423 15 175 125 1053 2736 464
TW35-3-AAC-4/0-7 4/0 7 475 15 175 125 1105 3447 527
TW35-3-AAC-266.8-19 266.8 19 537 15 175 125 1167 4473 603
TW35-3-AAC-336.4-19 336.4 19 603 15 175 125 1233 5535 696
TW35-3-AAC-397.5-19 397.5 19 659 15 175 125 1289 6399 777
TW35-3-AAC-477-19 477 19 722 20 175 125 1362 7524 889
TW35-3-AAC-556.5-37 556.5 37 780 20 175 125 1420 8946 987
TW35-3-AAC-636-37 636 37 835 20 175 125 1475 10260 1085
TW35-3-AAC-795-37 795 37 932 20 175 125 1572 12510 1278

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
421 Information on this sheet subject to change without notice.
20160208 Copyright © 2018, American Wire Group, Inc.
AAC
3 Layer 35kV
Electrical Properties

DISTRIBUTION CABLES
TRANSMISSION.&
Application • ASTM B230 Standard Specification for Alu-
Used for primary and secondary overhead dis- minum 1350–H19 Wire for Electrical Purposes
tribution where limited space is available or de- • ASTM B231 Standard Specification for Con-
sirable for rights of way. Installed as an centric-Lay-Stranded Aluminum 1350 Conduc-
uninsulated conductor; however, covering is ef- tors
fective in preventing direct shorts and instanta- • ASTM B232 Standard Specification for Con-
neous flashovers should tree limbs or other centric-Lay-Stranded Aluminum Conductors,
objects contact conductors in such close prox- Coated-Steel Reinforced (ACSR)
imity. The resulting close-proximity configura- • ASTM B398 Standard Specification for Alu-
tion minimizes the amount of space and minum-Alloy 6201-T81 and 6201-T83 Wire for
hardware required for line installation; particu- Electrical Purposes
larly useful in congested areas such as alley- • ASTM B399 Standard Specification for Con-
ways or tight corridors. centric-Lay-Stranded Aluminum-Alloy 6201-
T81 Conductors
Construction • ASTM B400 Standard Specification for Com-
Conductors are concentric strand AAC (1350- pact Round Concentric-Lay-Stranded Conduc-
H19), AAAC (either compressed or full compact tors
depending on conductor size) or ACSR. The con- • ASTM D2656 Standard Specification for
ductor shield shall be an extruded back semi- Cross-linked Polyethylene Insulation for Wire
conductor polymer meeting the physical and Cable Rated 2001 to 35 000 V
requirements of ICEA S-61-402. Available with • ASTM D1248 Standard Specification for Poly-
track-resistant high-density polyethylene (TR- ethylene Plastics Extrusion Materials for Wire
HDPE) per ASTM D1248 or Track-Resistant and Cable
Cross-linked Polyethylene (XLPE) covering per • ICEA S-70-547 Standard Specification for
ASTM D2656. The minimum thickness of each Weather Resistant Polyethylene Covered Con-
layer at any point shall not be less than listed in ductors
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to Notes
provide the weather resistance, and track resist- Full hardware solution is available, including
ance. spacers, brackets, installation tools and hard-
ware. Please consult with AWG for more infor-
Specification mation.
15kV - 35kV Covered Aerial Medium Voltage
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifica-
tions:

Item # Size Strands AC AC AC GMR Inductive Inductive Inductive Inductive Inductive Impedance Impedance Impedance Impedance Impedance
AWG or Resistance Resistance Resistance (ft) Reactance Reactance Reactance Reactance Reactance Z@75°C Z@75°C Z@75°C Z@75°C Z@75°C
kcmil @25°C @75°C @90°C ohms/mile ohms/mile ohms/mile ohms/mile ohms/mile ohms/mile ohms/mile ohms/mile ohms/mile ohms/mile
ohms/mile ohms/mile ohms/mile w/H-46D w/H-35D w/RTL-15 w/RTL-46 w/RTL-G095 H-46D H-35D RTL-15 RTL-46 RTL-G095
TW35-3-AAC-2-7 2 7 1.4020 1.1810 1.7640 0.0088 0.5691 0.5763 0.5252 0.5691 0.5235 1.7747 1.7770 1.7611 1.7747 1.7929
TW35-3-AAC-1/0-7 1/0 7 0.8820 1.0580 1.1100 0.0109 0.5432 0.5503 0.4992 0.5432 0.5975 1.1889 1.1921 1.1694 1.1889 1.2147
TW35-3-AAC-2/0-7 2/0 7 0.7000 0.8390 0.0881 0.0122 0.5295 0.5366 0.4855 0.5295 0.5839 0.9924 0.9962 0.9696 0.9924 1.0224
TW35-3-AAC-3/0-7 3/0 7 0.5560 0.6670 0.6990 0.0137 0.5154 0.5226 0.4715 0.5154 0.5698 0.8427 0.8470 0.8165 0.8427 0.8770
TW35-3-AAC-4/0-7 4/0 7 0.4410 0.5290 0.5550 0.0154 0.5012 0.5084 0.4573 0.5012 0.5556 0.7286 0.7335 0.6991 0.7286 0.7670
TW35-3-AAC-266.8-7 266.8 7 0.3500 0.4200 0.4400 0.0169 0.4900 0.4971 0.4460 0.4900 0.5443 0.6451 0.6505 0.6124 0.6451 0.6873
TW35-3-AAC-336.4-19 336.4 19 0.2780 0.3330 0.3500 0.0200 0.4695 0.4767 0.4256 0.4695 0.5239 0.5758 0.5816 0.5406 0.5758 0.6209
TW35-3-AAC-397.5-19 397.5 19 0.2350 0.2820 0.2960 0.0215 0.4607 0.4679 0.4168 0.4607 0.5151 0.5401 0.5462 0.5031 0.5401 0.5871
TW35-3-AAC-477-19 477 19 0.1970 0.2360 0.2480 0.0239 0.4479 0.4550 0.4039 0.4479 0.5023 0.5064 0.5127 0.4679 0.5064 0.5550
TW35-3-AAC-556.5-19 556.5 19 0.1690 0.2030 0.2130 0.0251 0.4420 0.4491 0.3980 0.4420 0.4963 0.4862 0.4927 0.4466 0.4862 0.5361
TW35-3-AAC-636-19 636 19 0.1490 0.1790 0.1870 0.0274 0.4313 0.4385 0.3874 0.4313 0.4857 0.4669 0.4735 0.4266 0.4669 0.5175
TW35-3-AAC-795-19 795 19 0.1200 0.1440 0.1510 0.0304 0.4187 0.4258 0.3747 0.4187 0.4731 0.4427 0.4495 0.4014 0.4427 0.4945
TW35-3-AAC-954-37 954 37 0.1010 0.1210 0.1270 0.0328 0.4095 0.4166 0.3655 0.4095 0.4639 0.4270 0.4339 0.3851 0.4270 0.4794
TW35-3-AAC-1033-37 1033 37 0.0930 0.1120 0.1170 0.0341 0.4048 0.4199 0.3608 0.4048 0.4591 0.4200 0.4268 0.3778 0.4200 0.4726
TW35-3-AAC-636-37 1272 61 0.0770 0.0930 0.0970 0.0385 0.3901 0.3972 0.3461 0.3901 0.4444 0.4009 0.4078 0.3582 0.4009 0.4540
TW35-3-AAC-795-37 1431 61 0.0700 0.0830 0.0870 0.0405 0.3839 0.3910 0.3399 0.3839 0.4383 0.3928 0.3998 0.3500 0.3928 0.4461

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 426
Copyright © 2018, American Wire Group, Inc. 20160208
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
SPACER CABLE TECHNICAL DATA FOR 3 LAYER COMPOUNDS

DISTRIBUTION CABLES
TRANSMISSION.&
The first layer data (inner layer) 35kV semi-conducting shield compound
DESCRIPTION UNIT REQUIRED VALUE

1 Color Black
2 Density (23℃) g/cm3 1.11
3 Tensile strength before aging Mpa min 14
Elongation at break before aging % min 200


4 Performance after air oven aging
Testing temperature 135±2
Testing time hours 168
Tensile strength variation before & after aging % 15
At-break-elongation variation before & after aging % -7.5
5 Hot set test (0.2MPa, 200℃, 15min)
Elongation under load % 43
Variation after cool % 0
6 Volume resistivity at 20℃ Ω.cm 33
7 Volume resistivity at 90℃ Ω.cm 181
8 Volume resistivity at 90℃ (volume resistivity at 90℃,
after air oven aging (100℃* 168 hours)) Ω.cm 124

The second layer data (middle layer) 35kV XLPE, color natural (clear)
DESCRIPTION UNIT REQUIRED VALUE

1 Color clear, natural


2 Density (23℃) g/cm3 0.926
3 Tensile strength before aging Mpa min 23
Elongation at break before aging % min 500


4 Performance after air oven aging
Testing temperature 135±2
Testing time hours 168
Tensile strength variation before & after aging % -9.3
At-break-elongation variation before & after aging % -17
5 Hot set test (0.2MPa, 200℃, 15min)
Elongation under load % 35
Variation after cool % 0
6 Dielectric loss factor , 20℃, 50Hz 0.0004
7 Dielectric coefficient , 20℃, 50Hz 2.1
8 Volume resistivity at 20℃ Ω.m 1.5x1013
9 Dielectric strength MV/m 35

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 427
Copyright © 2018, American Wire Group, Inc. 20160216
SPACER CABLE TECHNICAL DATA FOR 3 LAYER COMPOUNDS
DISTRIBUTION CABLES
TRANSMISSION &

The third layer data (outer layer) 35kV XLPE, Gray, UV resistant, weather resistant
DESCRIPTION UNIT REQUIRED VALUE

1 Color Gray
2 Density (23℃) g/cm3 0.926
3 Tensile strength before aging Mpa min 24.7
Elongation at break before aging % min 521


4 Performance after air oven aging
Testing temperature 135±2
Testing time hours 168
Tensile strength variation before & after aging % -7
At-break-elongation variation before & after aging % -5
5 Hot set test (0.2MPa, 200℃, 15min)
Elongation under load % 33
Variation after cool % 0
6 Dielectric loss factor, 20℃, 50Hz 0.00005
7 Dielectric coefficient, 20℃, 50Hz 2.0
8 Volume resistivity at 20℃ Ω.m 1.4x1015
9 Dielectric strength MV/m 35

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
427 Information on this sheet subject to change without notice.
20160216 Copyright © 2018, American Wire Group, Inc.
AAAC
2 Layer 15kV

DISTRIBUTION CABLES
TRANSMISSION.&
Application • ASTM B230 Standard Specification for Alu-
Used for primary and secondary overhead dis- minum 1350–H19 Wire for Electrical Purposes
tribution where limited space is available or de- • ASTM B231 Standard Specification for Con-
sirable for rights of way. Installed as an centric-Lay-Stranded Aluminum 1350 Conduc-
uninsulated conductor; however, covering is ef- tors
fective in preventing direct shorts and instanta- • ASTM B232 Standard Specification for Con-
neous flashovers should tree limbs or other centric-Lay-Stranded Aluminum Conductors,
objects contact conductors in such close prox- Coated-Steel Reinforced (ACSR)
imity. The resulting close-proximity configura- • ASTM B398 Standard Specification for Alu-
tion minimizes the amount of space and minum-Alloy 6201-T81 and 6201-T83 Wire for
hardware required for line installation; particu- Electrical Purposes
larly useful in congested areas such as alley- • ASTM B399 Standard Specification for Con-
ways or tight corridors. centric-Lay-Stranded Aluminum-Alloy 6201-
T81 Conductors
Construction • ASTM B400 Standard Specification for Com-
Conductors are concentric strand AAC (1350- pact Round Concentric-Lay-Stranded Conduc-
H19), AAAC (either compressed or full compact tors
depending on conductor size) or ACSR. The con- • ASTM D2656 Standard Specification for
ductor shield shall be an extruded back semi- Cross-linked Polyethylene Insulation for Wire
conductor polymer meeting the physical and Cable Rated 2001 to 35 000 V
requirements of ICEA S-61-402. Available with • ASTM D1248 Standard Specification for Poly-
track-resistant high-density polyethylene (TR- ethylene Plastics Extrusion Materials for Wire
HDPE) per ASTM D1248 or Track-Resistant and Cable
Cross-linked Polyethylene (XLPE) covering per • ICEA S-70-547 Standard Specification for
ASTM D2656. The minimum thickness of each Weather Resistant Polyethylene Covered Con-
layer at any point shall not be less than listed in ductors
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to
provide the weather resistance, and track resist- Notes
ance. Full hardware solution is available, including
spacers, brackets, installation tools and hard-
Specification ware. Please consult with AWG for more infor-
15kV - 35kV Covered Aerial Medium Voltage mation.
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifica-
tions:

Item # Size Equivalent Stranding Conductor Covering Covering Cable Rated Weight
AWG or AAC Diameter Thickness Thickness O.D. Strength (lb/MFT)
kcmil AWG or (mil) Inner Outer (mil) (lb)
kcmil Layer Layer
(mil) (mil)
TW15-2-AAAC-48.69-7 48.69 4 7 250 75 75 550 1584 124
TW15-2-AAAC-77.47-7 77.47 2 7 316 75 75 616 2520 165
TW15-2-AAAC-123.3-7 123.3 1/0 7 398 75 75 698 4014 225
TW15-2-AAAC-155.4-7 155.4 2/0 7 447 75 75 747 4851 265
TW15-2-AAAC-195.7-7 195.7 3/0 7 502 75 75 802 6111 314
TW15-2-AAAC-246.9-7 246.9 4/0 7 563 75 75 863 7704 376
TW15-2-AAAC-312.8-19 312.8 266.8 19 642 75 75 942 9900 450
TW15-2-AAAC-394.5-19 394.5 336.4 19 720 75 75 1020 11970 543
TW15-2-AAAC-465.4-19 465.4 397.5 19 782 75 75 1082 14040 623
TW15-2-AAAC-559.5-19 559.5 477 19 858 75 75 1158 16920 727
TW15-2-AAAC-652.4-19 652.4 556.5 19 927 75 75 1227 19710 828
TW15-2-AAAC-740.8-37 740.8 636 37 990 80 80 1310 21960 938

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 422
Copyright © 2018, American Wire Group, Inc. 20160108
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
AAAC
3 Layer 15k-35kV

DISTRIBUTION CABLES
TRANSMISSION.&
Application • ASTM B230 Standard Specification for Alu-
Used for primary and secondary overhead dis- minum 1350–H19 Wire for Electrical Purposes
tribution where limited space is available or de- • ASTM B231 Standard Specification for Con-
sirable for rights of way. Installed as an centric-Lay-Stranded Aluminum 1350 Conduc-
uninsulated conductor; however, covering is ef- tors
fective in preventing direct shorts and instanta- • ASTM B232 Standard Specification for Con-
neous flashovers should tree limbs or other centric-Lay-Stranded Aluminum Conductors,
objects contact conductors in such close prox- Coated-Steel Reinforced (ACSR)
imity. The resulting close-proximity configura- • ASTM B398 Standard Specification for Alu-
tion minimizes the amount of space and minum-Alloy 6201-T81 and 6201-T83 Wire for
hardware required for line installation; particu- Electrical Purposes
larly useful in congested areas such as alley- • ASTM B399 Standard Specification for Con-
ways or tight corridors. centric-Lay-Stranded Aluminum-Alloy 6201-
T81 Conductors
Construction • ASTM B400 Standard Specification for Com-
Conductors are concentric strand AAC (1350- pact Round Concentric-Lay-Stranded Conduc-
H19), AAAC (either compressed or full compact tors
depending on conductor size) or ACSR. The con- • ASTM D2656 Standard Specification for
ductor shield shall be an extruded back semi- Cross-linked Polyethylene Insulation for Wire
conductor polymer meeting the physical and Cable Rated 2001 to 35 000 V
requirements of ICEA S-61-402. Available with • ASTM D1248 Standard Specification for Poly-
track-resistant high-density polyethylene (TR- ethylene Plastics Extrusion Materials for Wire
HDPE) per ASTM D1248 or Track-Resistant and Cable
Cross-linked Polyethylene (XLPE) covering per • ICEA S-70-547 Standard Specification for
ASTM D2656. The minimum thickness of each Weather Resistant Polyethylene Covered Con-
layer at any point shall not be less than listed in ductors
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to
provide the weather resistance, and track resist- Notes
ance. Full hardware solution is available, including
spacers, brackets, installation tools and hard-
Specification ware. Please consult with AWG for more infor-
15kV - 35kV Covered Aerial Medium Voltage mation.
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifica-
tions:

Item # Size Equivalent Stranding Conductor Covering Covering Covering Cable Rated Weight
AWG or AAC Diameter Thickness Thickness Thickness O.D. Strength (lb/MFT)
kcmil AWG or (mil) Conductor Inner Outer (mil) (lb)
kcmil Shield Layer Layer
(mil) (mil) (mil)
15kV
TW15-3-AAAC-48.69-7 48.69 4 7 250 15 75 75 580 1584 137
TW15-3-AAAC-77.47-7 77.47 2 7 316 15 75 75 646 2520 179
TW15-3-AAAC-123.3-7 123.3 1/0 7 398 15 75 75 728 4014 241
TW15-3-AAAC-155.4-7 155.4 2/0 7 447 15 75 75 777 4851 283
TW15-3-AAAC-195.7-7 195.7 3/0 7 502 15 75 75 832 6111 334
TW15-3-AAAC-246.9-7 246.9 4/0 7 563 15 75 75 893 7704 397
TW15-3-AAAC-312.8-19 312.8 266.8 19 642 15 75 75 972 9900 473
TW15-3-AAAC-394.5-19 394.5 336.4 19 720 15 75 75 1050 11970 568
TW15-3-AAAC-465.4-19 465.4 397.5 19 783 15 75 75 1113 14040 649
TW15-3-AAAC-559.5-19 559.5 477 19 858 15 75 75 1188 16920 755
TW15-3-AAAC-652.4-19 652.4 556.5 19 927 20 75 75 1267 19710 894
TW15-3-AAAC-740.8-37 740.8 636 37 990 20 75 75 1330 21960 963

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 423
Copyright © 2018, American Wire Group, Inc. 20160208
AAAC
3 Layer 15k-35kV
DISTRIBUTION CABLES
TRANSMISSION &

Item # Size Equivalent Stranding Conductor Covering Covering Covering Cable Rated Weight
AWG or AAC Diameter Thickness Thickness Thickness O.D. Strength (lb/MFT)
kcmil AWG or (mil) Conductor Inner Outer (mil) (lb)
kcmil Shield Layer Layer
(mil) (mil) (mil)
25kV
TW25-3-AAAC-48.69-7 48.69 4 7 250 15 125 125 780 1584 225
TW25-3-AAAC-77.47-7 77.47 2 7 316 15 125 125 846 2520 275
TW25-3-AAAC-123.3-7 123.3 1/0 7 398 15 125 125 928 4014 348
TW25-3-AAAC-155.4-7 155.4 2/0 7 447 15 125 125 977 4851 396
TW25-3-AAAC-195.7-7 195.7 3/0 7 502 15 125 125 1032 6111 454
TW25-3-AAAC-246.9-7 246.9 4/0 7 563 15 125 125 1093 7704 525
TW25-3-AAAC-312.8-19 312.8 266.8 19 642 15 125 125 1172 9900 611
TW25-3-AAAC-394.5-19 394.5 336.4 19 720 15 125 125 1251 11970 716
TW25-3-AAAC-465.4-19 465.4 397.5 19 783 15 125 125 1313 14040 805
TW25-3-AAAC-559.5-19 559.5 477 19 858 20 125 125 1398 16920 932
TW25-3-AAAC-652.4-19 652.4 556.5 19 927 20 125 125 1467 19710 1044
TW25-3-AAAC-740.8-37 740.8 636 37 990 20 125 125 1530 21960 1148
TW25-3-AAAC-927.2-37 927.2 795 37 1108 20 125 125 1648 27450 1389
35kV
TW35-3-AAAC-48.69-7 48.69 4 7 250 15 175 125 880 1584 278
TW35-3-AAAC-77.47-7 77.47 2 7 316 15 175 125 946 2520 333
TW35-3-AAAC-123.3-7 123.3 1/0 7 398 15 175 125 1028 4014 411
TW35-3-AAAC-155.4-7 155.4 2/0 7 447 15 175 125 1077 4851 462
TW35-3-AAAC-195.7-7 195.7 3/0 7 502 15 175 125 1132 6111 523
TW35-3-AAAC-246.9-7 246.9 4/0 7 563 15 175 125 1193 7704 598
TW35-3-AAAC-312.8-19 312.8 266.8 19 642 15 175 125 1272 9900 689
TW35-3-AAAC-394.5-19 394.5 336.4 19 720 15 175 125 1351 11970 799
TW35-3-AAAC-465.4-19 465.4 397.5 19 783 15 175 125 1412 14040 892
TW35-3-AAAC-559.5-19 559.5 477 19 858 20 175 125 1498 16920 1024
TW35-3-AAAC-652.4-19 652.4 556.5 19 927 20 175 125 1567 19710 1141

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
423 Information on this sheet subject to change without notice.
20160208 Copyright © 2018, American Wire Group, Inc.
ACSR
2 Layer 15kV

DISTRIBUTION CABLES
TRANSMISSION.&
Application • ASTM B230 Standard Specification for Alu-
Used for primary and secondary overhead dis- minum 1350–H19 Wire for Electrical Purposes
tribution where limited space is available or de- • ASTM B231 Standard Specification for Con-
sirable for rights of way. Installed as an centric-Lay-Stranded Aluminum 1350 Conduc-
uninsulated conductor; however, covering is ef- tors
fective in preventing direct shorts and instanta- • ASTM B232 Standard Specification for Con-
neous flashovers should tree limbs or other centric-Lay-Stranded Aluminum Conductors,
objects contact conductors in such close prox- Coated-Steel Reinforced (ACSR)
imity. The resulting close-proximity configura- • ASTM B398 Standard Specification for Alu-
tion minimizes the amount of space and minum-Alloy 6201-T81 and 6201-T83 Wire for
hardware required for line installation; particu- Electrical Purposes
larly useful in congested areas such as alley- • ASTM B399 Standard Specification for Con-
ways or tight corridors. centric-Lay-Stranded Aluminum-Alloy 6201-
T81 Conductors
Construction • ASTM B400 Standard Specification for Com-
Conductors are concentric strand AAC (1350- pact Round Concentric-Lay-Stranded Conduc-
H19), AAAC (either compressed or full compact tors
depending on conductor size) or ACSR. The con- • ASTM D2656 Standard Specification for
ductor shield shall be an extruded back semi- Cross-linked Polyethylene Insulation for Wire
conductor polymer meeting the physical and Cable Rated 2001 to 35 000 V
requirements of ICEA S-61-402. Available with • ASTM D1248 Standard Specification for Poly-
track-resistant high-density polyethylene (TR- ethylene Plastics Extrusion Materials for Wire
HDPE) per ASTM D1248 or Track-Resistant and Cable
Cross-linked Polyethylene (XLPE) covering per • ICEA S-70-547 Standard Specification for
ASTM D2656. The minimum thickness of each Weather Resistant Polyethylene Covered Con-
layer at any point shall not be less than listed in ductors
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to
provide the weather resistance, and track resist- Notes
ance. Full hardware solution is available, including
spacers, brackets, installation tools and hard-
Specification ware. Please consult with AWG for more infor-
15kV - 35kV Covered Aerial Medium Voltage mation.
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifica-
tions:

Item # Size Stranding Conductor Covering Covering Cable Rated Weight


AWG or Diameter Thickness Thickness O.D. Strength (lb/MFT)
kcmil (mil) Inner Outer (mil) (lb)
Layer Layer
(mil) (mil)
TW15-2-ACSR-4-6/1 4 6/1 250 75 75 550 1767 136
TW15-2-ACSR-2-6/1 2 6/1 316 75 75 616 2708 184
TW15-2-ACSR-1/0-6/1 1/0 6/1 398 75 75 698 4161 255
TW15-2-ACSR-2/0-6/1 2/0 6/1 447 75 75 747 5045 303
TW15-2-ACSR-3/0-6/1 3/0 6/1 502 75 75 802 6289 362
TW15-2-ACSR-4/0-6/1 4/0 6/1 563 75 75 863 7933 432
TW15-2-ACSR-266.8-18/1 266.8 18/1 609 75 75 909 6536 441
TW15-2-ACSR-266.8-26/7 266.8 26/7 642 75 75 942 10735 452
TW15-2-ACSR-336.4-18/1 336.4 18/1 684 75 75 984 8246 536
TW15-2-ACSR-336.4-26/7 336.4 26/7 720 75 75 1020 13395 555
TW15-2-ACSR-336.4-30/7 336.4 30/7 741 75 75 1041 16435 621
TW15-2-ACSR-397.5-18/1 397.5 18/1 743 75 75 1043 9443 611
TW15-2-ACSR-397.5-24/7 397.5 24/7 772 75 75 1072 13870 609
TW15-2-ACSR-397.5-26/7 397.5 26/7 783 75 75 1083 1545 645

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 424
Copyright © 2018, American Wire Group, Inc. 20160208
ACSR
2 Layer 15kV
DISTRIBUTION CABLES
TRANSMISSION &

Item # Size Stranding Conductor Covering Covering Cable Rated Weight


AWG or Diameter Thickness Thickness O.D. Strength (lb/MFT)
kcmil (mil) Inner Outer (mil) (lb)
Layer Layer
(mil) (mil)
TW15-2-ACSR-477-24/7 477 24/7 846 75 75 1146 16340 719
TW15-2-ACSR-477-26/7 477 26/7 858 75 75 1158 18525 762
TW15-2-ACSR-477-30/7 477 30/7 883 75 75 1183 22610 854
TW15-2-ACSR-556.5-18/1 556.5 18/1 879 75 75 1179 13015 813
TW15-2-ACSR-556.5-24/7 556.5 24/7 914 75 75 1214 18810 828
TW15-2-ACSR-556.5-26/7 556.5 26/7 927 75 75 1227 21470 878
TW15-2-ACSR-636-18/1 636 18/1 940 75 75 1240 14915 912
TW15-2-ACSR-636-24/7 636 24/7 977 75 75 1277 20900 936
TW15-2-ACSR-636-26/7 636 26/7 990 75 75 1290 23940 993
TW15-2-ACSR-795-26/7 795 26/7 1108 80 80 1428 29925 1234
TW15-2-ACSR-795-45/7 795 45/7 1063 80 80 1383 20995 1031

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
424 Information on this sheet subject to change without notice.
20160208 Copyright © 2018, American Wire Group, Inc.
ACSR
3 Layer 15kV-35kV

DISTRIBUTION CABLES
TRANSMISSION.&
Application • ASTM B230 Standard Specification for Alu-
Used for primary and secondary overhead dis- minum 1350–H19 Wire for Electrical Purposes
tribution where limited space is available or de- • ASTM B231 Standard Specification for Con-
sirable for rights of way. Installed as an centric-Lay-Stranded Aluminum 1350 Conduc-
uninsulated conductor; however, covering is ef- tors
fective in preventing direct shorts and instanta- • ASTM B232 Standard Specification for Con-
neous flashovers should tree limbs or other centric-Lay-Stranded Aluminum Conductors,
objects contact conductors in such close prox- Coated-Steel Reinforced (ACSR)
imity. The resulting close-proximity configura- • ASTM B398 Standard Specification for Alu-
tion minimizes the amount of space and minum-Alloy 6201-T81 and 6201-T83 Wire for
hardware required for line installation; particu- Electrical Purposes
larly useful in congested areas such as alley- • ASTM B399 Standard Specification for Con-
ways or tight corridors. centric-Lay-Stranded Aluminum-Alloy 6201-
T81 Conductors
Construction • ASTM B400 Standard Specification for Com-
Conductors are concentric strand AAC (1350- pact Round Concentric-Lay-Stranded Conduc-
H19), AAAC (either compressed or full compact tors
depending on conductor size) or ACSR. The con- • ASTM D2656 Standard Specification for
ductor shield shall be an extruded back semi- Cross-linked Polyethylene Insulation for Wire
conductor polymer meeting the physical and Cable Rated 2001 to 35 000 V
requirements of ICEA S-61-402. Available with • ASTM D1248 Standard Specification for Poly-
track-resistant high-density polyethylene (TR- ethylene Plastics Extrusion Materials for Wire
HDPE) per ASTM D1248 or Track-Resistant and Cable
Cross-linked Polyethylene (XLPE) covering per • ICEA S-70-547 Standard Specification for
ASTM D2656. The minimum thickness of each Weather Resistant Polyethylene Covered Con-
layer at any point shall not be less than listed in ductors
the data table. The outer layer shall contain a
carbon black additive, not less than 0.02% to
provide the weather resistance, and track resist- Notes
ance. Full hardware solution is available, including
spacers, brackets, installation tools and hard-
Specification ware. Please consult with AWG for more infor-
15kV - 35kV Covered Aerial Medium Voltage mation.
Cable wire meets or exceeds all applicable ICEA
specifications and the following ASTM specifica-
tions:

Item # Size Stranding Conductor Covering Covering Covering Cable Rated Weight
AWG or Diameter Thickness Thickness Thickness O.D. Strength (lb/MFT)
kcmil (mil) Conductor Inner Outer (mil) (lb)
Shield Layer Layer
(mil) (mil) (mil)
15kV
TW15-3-ACSR-4-6/1 4 6/1 250 15 75 75 580 1767 151
TW15-3-ACSR-2-6/1 2 6/1 316 15 75 75 646 2708 202
TW15-3-ACSR-1/0-6/1 1/0 6/1 398 15 75 75 728 4161 278
TW15-3-ACSR-2/0-6/1 2/0 6/1 447 15 75 75 777 5045 330
TW15-3-ACSR-3/0-6/1 3/0 6/1 502 15 75 75 832 6289 393
TW15-3-ACSR-4/0-6/1 4/0 6/1 563 15 75 75 893 7933 471
TW15-3-ACSR-266.8-18/1 266.8 18/1 609 15 75 75 939 6536 474
TW15-3-ACSR-266.8-26/7 266.8 26/7 642 15 75 75 972 10735 553
TW15-3-ACSR-336.4-18/1 336.4 18/1 684 15 75 75 1014 8246 570
TW15-3-ACSR-336.4-26/7 336.4 26/7 720 15 75 75 1050 13395 669
TW15-3-ACSR-336.4-30/7 336.4 30/7 741 15 75 75 1071 16435 935
TW15-3-ACSR-397.5-18/1 397.5 18/1 743 15 75 75 1073 9443 653
TW15-3-ACSR-397.5-24/7 397.5 24/7 772 15 75 75 1102 13870 707
TW15-3-ACSR-397.5-26/7 397.5 26/7 783 15 75 75 1113 15485 770
TW15-3-ACSR-477-24/7 477 24/7 846 15 75 75 1176 16340 824

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 425
Copyright © 2018, American Wire Group, Inc. 20160208
ACSR
3 Layer 15kV-35kV
DISTRIBUTION CABLES
TRANSMISSION &

Item # Size Stranding Conductor Covering Covering Covering Cable Rated Weight
AWG or Diameter Thickness Thickness Thickness O.D. Strength (lb/MFT)
kcmil (mil) Conductor Inner Outer (mil) (lb)
Shield Layer Layer
(mil) (mil) (mil)
TW15-3-ACSR-477-26/7 477 26/7 858 15 75 75 1188 18525 899
TW15-3-ACSR-477-30/7 477 30/7 883 15 75 75 1213 22610 1274
TW15-3-ACSR-556.5-18/1 556.5 18/1 879 20 75 75 1219 13015 874
TW15-3-ACSR-556.5-24/7 556.5 24/7 914 20 75 75 1254 18810 949
TW15-3-ACSR-556.5-26/7 556.5 26/7 927 20 75 75 1267 21470 1036
TW15-3-ACSR-636-18/1 636 18/1 940 20 75 75 1280 14915 1200
TW15-3-ACSR-636-26/7 636 26/7 990 20 75 75 1330 23940 1373
25kV
TW25-3-ACSR-1/0-6/1 1/0 6/1 398 15 125 125 928 4161 385
TW25-3-ACSR-2/0-6/1 2/0 6/1 447 15 125 125 977 5045 443
TW25-3-ACSR-3/0-6/1 3/0 6/1 502 15 125 125 1032 6289 513
TW25-3-ACSR-4/0-6/1 4/0 6/1 563 15 125 125 1093 7933 600
TW25-3-ACSR-266.8-18/1 266.8 18/1 609 15 125 125 1139 6536 608
TW25-3-ACSR-266.8-26/7 266.8 26/7 642 15 125 125 1172 10735 692
TW25-3-ACSR-336.4-18/1 336.4 18/1 684 15 125 125 1214 8246 714
TW25-3-ACSR-336.4-26/7 336.4 26/7 720 15 125 125 1250 13395 818
TW25-3-ACSR-336.4-30/7 336.4 30/7 741 15 125 125 1271 16435 1086
TW25-3-ACSR-397.5-18/1 397.5 18/1 743 15 125 125 1273 9443 804
TW25-3-ACSR-397.5-24/7 397.5 24/7 772 15 125 125 1302 13870 863
TW25-3-ACSR-397.5-26/7 397.5 26/7 783 15 125 125 1313 15485 926
TW25-3-ACSR-477-24/7 477 24/7 846 20 125 125 1386 16340 999
TW25-3-ACSR-477-26/7 477 26/7 858 20 125 125 1398 18525 1076
TW25-3-ACSR-477-30/7 477 30/7 883 20 125 125 1423 22610 1458
TW25-3-ACSR-556.5-18/1 556.5 18/1 879 20 125 125 1419 13015 1045
TW25-3-ACSR-556.5-24/7 556.5 24/7 914 20 125 125 1454 18810 1124
TW25-3-ACSR-556.5-26/7 556.5 26/7 927 20 125 125 1467 21470 1213
35kV
TW35-3-ACSR-1/0-6/1 1/0 6/1 398 15 175 125 1028 4161 448
TW35-3-ACSR-2/0-6/1 2/0 6/1 447 15 175 125 1077 5045 509
TW35-3-ACSR-4/0-6/1 4/0 6/1 563 15 175 125 1193 7933 673
TW35-3-ACSR-266.8-18/1 266.8 18/1 609 15 175 125 1239 6536 684
TW35-3-ACSR-266.8-26/7 266.8 26/7 642 15 175 125 1272 10735 770
TW35-3-ACSR-336.4-18/1 336.4 18/1 684 15 175 125 1314 8246 794
TW35-3-ACSR-336.4-26/7 336.4 26/7 720 15 175 125 1350 13395 901
TW35-3-ACSR-336.4-30/7 336.4 30/7 741 15 175 125 1371 16435 1170
TW35-3-ACSR-397.5-18/1 397.5 18/1 743 15 175 125 1373 9443 889
TW35-3-ACSR-397.5-24/7 397.5 24/7 772 15 175 125 1402 13870 949
TW35-3-ACSR-397.5-26/7 397.5 26/7 783 15 175 125 1413 15485 1013
TW35-3-ACSR-477-24/7 477 24/7 846 20 175 125 1486 16340 1091
TW35-3-ACSR-477-26/7 477 26/7 858 20 175 125 1498 18525 1168
TW35-3-ACSR-477-30/7 477 30/7 883 20 175 125 1523 22610 1552
TW35-3-ACSR-556.5-18/1 556.5 18/1 879 20 175 125 1519 13015 1138
TW35-3-ACSR-556.5-24/7 556.5 24/7 914 20 175 125 1554 18810 1220
TW35-3-ACSR-556.5-26/7 556.5 26/7 927 20 175 125 1567 21470 1309
TW35-3-ACSR-636-18/1 636 18/1 940 20 175 125 1580 14915 1637
TW35-3-ACSR-636-26/7 636 26/7 990 20 175 125 1630 23940 1826
TW35-3-ACSR-795-26/7 795 26/7 1107 20 175 125 1747 29925 2146
TW35-3-ACSR-795-45/7 795 45/7 1063 20 175 125 1703 20995 1892

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
425 Information on this sheet subject to change without notice.
20160208 Copyright © 2018, American Wire Group, Inc.
Covered CU Line Wire
Weatherproof

DISTRIBUTION CABLES
TRANSMISSION.&
Description
Copper line wire available in vearious sizes, tempers and strandings with HMW-Polyethylene cover-
ing or crosslinked.

Application
Primary and secondary distribution on pole lines, service from pole to weatherhead, distribution in-
foors and out. Mining, industrial, railroad and other application.

Specification
• ASTM B1 Hard-Drawn Copper Wire
• ASTM B2 Medium-Hard-Drawn Copper WIre
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B4 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft
• ASTM D-1248 Polyethylene Plastics, Molding and Extrusion Materials
• ANSI C-8.35 Specifications for Weather-Resistant Polyethylene-Covered Wire and Cable

Item # Size Stranding Insulation Poly XLP


Thickness Weight Weight
(in) /MFT /MFT
(lb) (lb)
14S-01WP 14 SOLID 2/64 16.0 16.5
12S-01WP 12 SOLID 2/64 24.0 24.6
10S-01WP 10 SOLID 2/64 36.5 37.1
9S-01WP 9 SOLID 2/64 45.0 45.7
8S-01WP 8 SOLID 2/64 56.0 56.8
6S-01WP 6 SOLID 2/64 87.0 87.8
4S-01WP 4 SOLID 2/64 136.0 137.0
3S-01WP 3 SOLID 3/64 176.0 177.4
2S-01WP 2 SOLID 3/64 219.0 222.0
1S-01WP 1 SOLID 3/64 273.0 277.0
1/0S-01WP 1/0 SOLID 4/64 350.0 355.0
2/0S-01WP 2/0 SOLID 4/64 437.0 443.0
6-01WP-7 6 7/W 2/64 91.5 92.0
4-01WP-7 4 7/W 2/64 143.0 144.0
2-01WP-7 2 7/W 3/64 230.0 233.0
1-01WP-7 1 7/W 3/64 287.0 291.0
1/0-01WP-7 1/0 7/W 4/64 367.0 372.0
1/0-01WP-19 1/0 19/W 4/64 367.0 372.0
2/0-01WP-7 2/0 7/W 4/64 458.0 464.0
2/0-01WP-19 2/0 19/W 4/64 458.0 464.0
3/0-01WP-7 3/0 7/W 4/64 572.0 578.0
3/0-01WP-19 3/0 19/W 4/64 572.0 578.0
4/0-01WP-7 4/0 7/W 4/64 715.0 722.0
4/0-01WP-19 4/0 19/W 4/64 715.0 722.0
250-01WP-19 250 19/W 4/64 834.0 842.0
300-01WP-19 300 19/W 4/64 996.0 1005.0
350-01WP-19 350 19/W 4/64 1157.0 1166.0
500-01WP-37 500 37/W 5/64 1648.0 1659.0
750-01WP-61 750 61/W 6/64 2481.0 2494.0

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 415
Copyright © 2018, American Wire Group, Inc. 20140902
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Cathodic Protection Cable

DISTRIBUTION CABLES
TRANSMISSION.&
Description
Soft drawn bare copper strand. High-molecular-weight, low density black polyethylene (HMW PE)
covering.

Application
Designed for use in Cathodic systems to protect against galvanic and electrolytic corrosion of un-
derground or submerged metallic objects. Specifically applied to underground pipelines, dams and
lock gates, fresh or salt water steel piles, tanks, condensers, and ship hulls.

Specification
• ASTM B-3 Bare Copper
• ASTM B-8 Class B Stranding
• ICEA S-70-547
• ASTM 1248

Item # Size AWG or MCM Stranding Insulation Thickness Nominal Weight Nominal Diameter
(mil) /MFT (in)
(lb)
8-01CPC 8 7/.0486 110 0.370 90
6-01CPC 6 7/.0612 110 0.410 125
4-01CPC 4 7/.0772 110 0.460 180
2-01CPC 2 7/.0974 110 0.520 272
1-01CPC 1 19/.0664 125 0.590 337
1/0-01CPC 1/0 19/.0745 125 0.630 415
2/0-01CPC 2/0 19/.0837 125 0.680 510
3/0-01CPC 3/0 19/.0940 125 0.735 625
4/0-01CPC 4/0 19/.1055 125 0.790 777
250-01CPC 250 37/.0822 155 0.900 935
350-01CPC 350 37/.0973 155 1.010 1269
500-01CPC 500 37/.1162 155 1.140 1770

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 416
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Transformer Riser Wire
(Tap Wire)

DISTRIBUTION CABLES
TRANSMISSION.&
Application
Used as non-insulated transformer risers intended to reduce faults due to atmospheric conditions,
vibrations, and crossed leads.

Construction
Soft drawn copper conductors, either solid or stranded, covered with HMW Polyethylene.

Standards
• ASTM B-3
• ASTM B-8
• ANSI C-8.35

Item # Size Stranding Covering Diameter Diameter Weight


Thickness Bare Conductor Covered /MFT
(mil) (mil) (mil) (lb)
TRW-8S 8 SOLID 110 128.5 348.5 83
TRW-6S 6 SOLID 110 162.0 382.0 117
TRW-6 6 .0612 7 STRANDS 110 184.0 404.0 122
TRW-4S 4 SOLID 110 204.3 424.3 170
TRW-4 4 .0772 7 STRANDS 110 232.0 452.0 177

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 417
Copyright © 2018, American Wire Group, Inc. 20140902
NOTES
DISTRIBUTION CABLES
TRANSMISSION &

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
MULTIPLEX CABLES
Table of Contents

Aluminum Duplex Overhead Service Drop 600V................................................................206


Aluminum Triplex Overhead Service Drop 600V ................................................................207
Aluminum Quadruplex Overhead Service Drop 600V .......................................................208
Copper Duplex Service Drop Cable 600V ............................................................................227
Copper Triplex Service Drop Cable 600V .............................................................................228

MULTIPLEX CABLES
Copper Quadruplex Service Drop Cable 600V ....................................................................229
Aluminum Single Secondary Type URD Cable ...................................................................209
Aluminum Duplex Secondary Type URD Cable ..................................................................210
Aluminum Triplex Secondary Type URD Cable ...................................................................211
Aluminum Quadruplex Secondary Type URD Cable ..........................................................212
Aluminum Mobile Home Feeder Type URD ........................................................................213
Packaging Information
Duplex Overhead Service Drop.........................................................................................214
Triplex Overhead Service Drop .........................................................................................215
Quadruplex Overhead Service Drop.................................................................................216
Secondary Type URD Cable 600V: Single, Duplex, Triplex, Quadruplex ........................217

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 1000
Copyright © 2018, American Wire Group, Inc. 20151123
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Aluminum Duplex Overhead Service Drop
600V

Applications
To supply 120V aerial service for temporary service at construction sites, outdoor or street lighting.
For service at 600V or lower at a conductor temperature of 75°C maximum.

Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene in-
sulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.

MULTIPLEX CABLES
Standards
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
• Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

Item # Phase Phase Phase Bare Bare Bare Weight Weight Ampacity Ampacity
Conductor Conductor Conductor Neutral Neutral Neutral /MFT /MFT XLP Poly
Size Stranding Insulation Messenger Messenger Messenger XLP Poly
AWG Thickness Size AWG Stranding Breaking (lb) (lb)
(mil) (lb)
AAC
Pekingese 6 Solid 45 6 7 563 63.5 61.7 85 70
Collie 6 7 45 6 7 563 66.8 63.1 85 70
Dachshund 4 Solid 45 4 7 881 95.5 93.4 115 90
Spaniel 4 7 45 4 7 881 100.5 95.4 115 90
Doberman 2 7 45 2 7 1350 152.7 145.7 150 120
Malemute 1/0 19 60 1/0 7 1990 242.6 234.2 205 160
ACSR Neutral Messenger
Setter 6 Solid 45 6 6/1 1190 75.0 73.2 85 70
Shepherd 6 7 45 6 6/1 1190 78.3 74.6 85 70
Eskimo 4 Solid 45 4 6/1 1860 113.7 111.6 115 90
Terrier 4 7 45 4 6/1 1860 118.7 113.6 115 90
Chow 2 7 45 2 6/1 2850 181.7 174.7 150 120
Bull 1/0 19 60 1/0 6/1 4380 288.7 280.3 205 160
AAAC 6201 Alloy Neutral Messenger
Chihuahua 6 Solid 45 6 7 1110 67.6 65.8 85 70
Vizsla 6 7 45 6 7 1110 70.9 67.2 85 70
Harrier 4 Solid 45 4 7 1760 102.0 99.9 115 90
Whippet 4 7 45 4 7 1760 107.0 101.9 115 90
Schnauzer 2 7 45 2 7 2800 163.3 156.2 150 120
Heeler 1/0 19 60 1/0 7 4460 259.2 250.8 250 160

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 206
Copyright © 2018, American Wire Group, Inc. 20160602
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Aluminum Triplex Overhead Service Drop
600V

Applications
To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600V or less
(phase to phase) at a conductor temperature of 75°C maximum for polyethylene Insulation or 90°C
maximum for cross-linked insulation.

Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene in-

MULTIPLEX CABLES
sulation, concentric strand AAC, ACSR or 6201 alloy neutral messenger.

Standards
• B-230 Aluminum Wire 1350-H19 for Electrical Purposes
• B-231 Aluminum Conductors, Concentric-Lay-Stranded
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
• B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
• Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-
474

Item # Phase Phase Phase Bare Bare Bare Weight Weight Ampacity Ampacity
Conductor Conductor Conductor Neutral Neutral Neutral /MFT /MFT XLP Poly
Size Stranding Insulation Messenger Messenger Messenger XLP Poly
AWG Thickness Size AWG Stranding Breaking (lb) (lb)
(mil) (lb)
AAC Neutral Messenger
Haiotis 6 Solid 45 6 7 563 102.5 98.8 85 70
Patella 6 7 45 6 7 563 109.1 101.6 85 70
Fusus 4 Solid 45 4 7 881 151.9 147.6 115 90
Oyster 4 7 45 4 7 881 161.8 151.7 115 90
Clam 2 7 45 2 7 1350 243.2 229.2 150 120
Murex 1/0 7 60 1/0 7 1990 395.1 369.4 205 160
Purpura 1/0 19 60 1/0 7 1990 386.1 369.4 205 160
Nassa 2/0 7 60 2/0 7 2510 485.8 455.3 235 185
Melita 3/0 19 60 3/0 19 3310 585.2 562.9 275 215
Portunus 4/0 19 60 4/0 19 4020 723.9 697.3 315 245
Nannynose 336.4 19 80 336.4 19 6146 1160.4 1118.0 420 325
Full Size ACSR Messenger
Paludina 6 Solid 45 6 6/1 1190 114 113 85 70
Voluta 6 7 45 6 6/1 1190 120 113 85 70
Whelk 4 Solid 45 4 6/1 1860 169 165 115 90
Periwinkle 4 7 45 4 6/1 1860 176 172 115 90
Conch 2 7 45 2 6/1 2850 267 261 150 120
Neritina 1/0 7 60 1/0 6/1 4380 530 419 205 160
Cenia 1/0 19 60 1/0 6/1 4380 426 416 205 160
Runcina 2/0 7 60 2/0 6/1 5310 530 519 235 185
Triton 2/0 19 60 2/0 6/1 5310 526 514 235 185
Cherrystone 3/0 7 60 3/0 6/1 6620 656 643 250 200
Mursia 3/0 19 60 3/0 6/1 6620 650 638 250 200
Razor 4/0 7 60 4/0 6/1 8350 814 799 315 245
Zuzara 4/0 19 60 4/0 6/1 8350 805 792 315 245
Limpet 336.4 19 80 336.4 18/1 8680 1209 1167 420 325

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 207
Copyright © 2018, American Wire Group, Inc. 20140921
Aluminum Triplex Overhead Service Drop
600V

Item # Phase Phase Phase Bare Bare Bare Weight Weight Ampacity Ampacity
Conductor Conductor Conductor Neutral Neutral Neutral /MFT /MFT XLP Poly
Size Stranding Insulation Messenger Messenger Messenger XLP Poly
AWG Thickness Size AWG Stranding Breaking (lb) (lb)
(mil) (lb)
ACSR Reduced Messenger
Scallop 4 Solid 45 6 6/1 1190 148 144 115 90
MULTIPLEX CABLES

Strombus 4 7 45 6 6/1 1190 158 148 115 90


Cockle 2 7 45 4 6/1 1860 233 227 150 120
Janthina 1/0 7 60 2 6/1 2850 376 365 205 160
Ranella 1/0 19 60 2 6/1 2850 372 362 205 160
Cavolinia 2/0 7 60 1 6/1 3550 462 451 235 185
Clio 2/0 19 60 1 6/1 3550 458 446 235 185
Sanddollar 3/0 7 60 1/0 6/1 4380 570 557 275 215
Aega 3/0 19 60 1/0 6/1 4380 565 552 275 215
Cuttlefish 4/0 7 60 2/0 6/1 5310 706 691 315 245
Cerapus 4/0 19 60 2/0 6/1 5310 699 684 315 245
Cowry 336.4 19 80 4/0 6/1 8350 1135 1093 420 325
AAAC 6201 Alloy Neutral Messenger
Minex 6 Solid 45 6 7 1110 106.6 102.9 85 70
Hippa 6 7 45 6 7 1110 113.2 105.7 85 70
Prawn 4 Solid 45 4 7 1760 158.4 154.1 115 90
Barnacles 4 7 45 4 7 1760 168.3 158.2 115 90
Shrimp 2 7 45 2 7 2800 253.7 239.7 150 120
Gammarus 1/0 7 60 1/0 7 4460 411.7 386.0 205 160
Leda 1/0 19 60 1/0 7 4460 402.7 386.0 205 160
Dungenese 2/0 7 60 2/0 7 5390 506.8 476.3 235 185
Cyclops 2/0 19 60 2/0 7 5390 495.3 476.3 235 185
Flustra 3/0 19 60 3/0 7 6790 611.4 589.1 275 215
Lepas 4/0 19 60 4/0 7 8560 757.1 730.5 315 245
AAAC 6201 Alloy Reduced Neutral Messenger
Artemia 4 Solid 45 6 7 1110 141.4 137.1 115 90
Crab 4 7 45 6 7 1110 151.3 141.2 115 90
Solaster 2 7 45 4 7 1760 226.6 212.6 150 120
Sandcrab 1/0 7 60 2 7 2800 368.8 343.1 205 160
Echinus 1/0 19 60 2 7 2800 358.8 343.1 205 160
Crayfish 2/0 7 60 1 7 3530 452.6 422.5 235 185
Sipho 2/0 19 60 1 7 3530 441.0 422.5 235 185
Fulgar 3/0 19 60 1/0 7 4460 543.4 521.1 275 215
Arca 4/0 19 60 2/0 7 5390 671.2 644.6 315 245

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
207 Information on this sheet subject to change without notice.
20140921 Copyright © 2018, American Wire Group, Inc.
Aluminum Quadruplex Overhead Service Drop
600V

Applications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user’s service head
where connection to the service entrance cable is made. To be used at voltages of 600V or less
phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated con-
ductors or 90°C for cross-linked polyethylene (XLP) insulated conductors.

Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either

MULTIPLEX CABLES
polyethylene or XLP cross-linked polyethylene. Neutral messengers are concentrically stranded
6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.

Standards
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
• B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
• Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-
474.
Note
Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB-
399 for 6201. Conductor temperature of 90°C for XLR 75°C for Poly; ambient temperatures of 40°C;
emissivity 0.9; 2ft./sec ind in sun. To determine current ampacity by conductor size, please consult
The National Electric Code, latest edition.

Item # Phase Phase Phase Bare Bare Bare Weight Weight Ampacity Ampacity
Conductor Conductor Conductor Neutral Neutral Neutral /MFT /MFT XLP Poly
Size Stranding Insulation Messenger Messenger Messenger XLP Poly
AWG Thickness Size AWG Stranding Breaking (lb) (lb)
(mil) (lb)
AAC Neutral Messenger
Clydesdale 4 Solid 45 4 7 881 208 201.8 100 80
Pinto 4 7 45 4 7 881 223 207.9 100 80
Mustang 2 7 45 2 7 1350 333 312.6 135 105
Criollo 1/0 19 60 1/0 7 1990 529 504.5 180 140
Percheron 2/0 19 60 2/0 7 2510 649 620.5 205 160
Hanoverian 3/0 19 60 3/0 19 3310 799 765.6 235 185
Oldenburg 4/0 19 60 4/0 19 4020 986 946.7 275 210
Lippizaner 336.4 19 80 336.4 19 6146 1546 1519.2 370 280
ACSR Neutral Messenger
Morochuca 6 Solid 45 6 6/1 1190 152 147.4 75 60
Chola 6 7 45 6 6/1 1190 162 151.7 75 60
Morgan 4 Solid 45 4 6/1 1860 226 220 100 80
Hackney 4 7 45 4 6/1 1860 241 226.1 100 80
Palomino 2 7 45 2 6/1 2850 362 342.6 135 105
Costena 1/0 19 60 1/0 6/1 4380 575 550.6 180 140
Grullo 2/0 19 60 2/0 6/1 5310 707 678.7 205 160
Suffolk 3/0 19 60 3/0 6/1 6620 872 838.9 235 185
Appaloosa 4/0 19 60 4/0 6/1 8350 1079 1039.2 275 210
Bronco 336.4 19 80 336.4 18/1 8580 1613 1568.2 370 280
Gelding 336.4 19 80 4/0 6/1 8350 1548 1494.3 370 280

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 208
Copyright © 2018, American Wire Group, Inc. 20140921
Aluminum Quadruplex Overhead Service Drop
600V

Item # Phase Phase Phase Bare Bare Bare Weight Weight Ampacity Ampacity
Conductor Conductor Conductor Neutral Neutral Neutral /MFT /MFT XLP Poly
Size Stranding Insulation Messenger Messenger Messenger XLP Poly
AWG Thickness Size AWG Stranding Breaking (lb) (lb)
(mil) (lb)
AAAC 6201 Alloy Neutral Messenger
Bay 6 Solid 45 6 7 1110 145 140.0 75 60
MULTIPLEX CABLES

French Coach 6 7/w 45 6 7 1110 155 144.3 75 60


German Coach 4 Solid 45 4 7 1760 214 208.3 100 80
Arabian 4 7/w 45 4 7 1760 229 214.4 100 80
Belgian 2 7/w 45 2 7 2800 344 323.1 135 105
Shetland 1/0 19/w 60 1/0 7 4460 546 521.1 180 140
Thoroughbred 2/0 19/w 60 2/0 7 5390 670 641.5 205 160
Trotter 3/0 19/w 60 3/0 7 6790 825 791.8 235 185
Walking 4/0 19/w 60 4/0 7 8560 1019 979.7 275 210

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
208 Information on this sheet subject to change without notice.
20140921 Copyright © 2018, American Wire Group, Inc.
Copper Duplex Service Drop Cable
600V

Application
Used to supply power, usually from a pole-mounted transformer, to the user's service head where
connection to the service entrance cable is made. Also suitable for installations for street lighting,
security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-
phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conduc-
tors and 90°C for cross-linked polyethylene (XLP) insulated conductors.

Specifications

MULTIPLEX CABLES
Meets or exceeds the following ASTM specifications:
• B-1 Hard-Drawn Copper Wire
• B-3 Soft or Annealed Copper Wire
• B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and
crosslinked polyethylene insulated conductors.

Construction
Conductors are concentrically stranded compressed soft copper insulated with either crosslinked
polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.

Notes:
• Code words for XLP insulated products are formed by adding "XLP" to the conventional polyethyl-
ene code words above (e.g. Theta/XLP).
• Ampacity figures for black insulation only. Based on conductor temperature of 75°C for polyethyl-
ene insulated conductors,90°C for XLP insulated conductors, ambient temperature of 40°C; 2
ft./sec. wind in sun.

Item # Phase Phase Phase Neutral Neutral Neutral Nominal Weight Weight Allowable Allowable
Conductor Conductor Conductor Messenger Messenger Messenger Lay /MFT /MFT Ampacities Ampacities
Size Stranding Cover Size Stranding Rated Length XLP Poly XLP Poly
AWG Thickness AWG Strength (in) (lb) (lb)
(mil) (lb)
Theta 8 7 45 10 1 529 10.36 96 97 85 70
Omega 8 1 45 8 1 826 10.36 112 113 85 70
Iota 8 7 45 8 1 826 10.36 115 116 85 70
Kappa 8 7 45 8 7 777 10.36 116 117 85 70
Lambda 6 7 45 8 1 826 10.36 149 149 110 90
Omicron 6 7 45 6 1 1280 10.36 179 179 110 90
Sigma 6 7 45 6 7 1228 10.36 180 181 110 90

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 227
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Copper Triplex Service Drop Cable
600V

Application
Used to supply power, usually from a pole-mounted transformer, to the user's service head where
connection to the service entrance cable is made. Also suitable for installations for street lighting,
security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-
phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conduc-
tors and 90°C for cross-linked polyethylene (XLP) insulated conductors.

Specifications

MULTIPLEX CABLES
Meets or exceeds the following ASTM specifications:
• B-1 Hard-Drawn Copper Wire
• B-3 Soft or Annealed Copper Wire
• B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and
crosslinked polyethylene insulated conductors.

Construction
Conductors are concentrically stranded compressed soft copper insulated with either crosslinked
polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.

Notes:
• Code words for XLP insulated products are formed by adding "XLP" to the conventional polyethyl-
ene code words above (e.g. Pica/XLP).
• Ampacity figures for black insulation only. Based on conductor temperature of 75°C for polyethyl
ene insulated conductors, 90°C for XLP insulated conductors, ambient temperature of 40°C; 2
ft./sec. wind in sun.

Item # Phase Phase Phase Neutral Neutral Neutral Nominal Weight Weight Allowable Allowable
Conductor Conductor Conductor Messenger Messenger Messenger Lay /MFT /MFT Ampacities Ampacities
Size Stranding Cover Size Stranding Rated Length XLP Poly XLP Poly
AWG Thickness AWG Strength (in) (lb) (lb)
(mil) (lb)
Pica 8 7 45 10 1 529 10.36 160 149 85 70
Columbian 8 1 45 8 1 826 10.36 174 164 85 70
Bodoni 8 7 45 8 1 826 10.36 179 167 85 70
Garamond 8 7 45 8 7 777 10.36 180 169 85 70
Tudor 6 7 45 8 1 826 14.88 246 232 110 90
Futura 6 7 45 6 1 1280 14.88 276 262 110 90
Gothic 6 7 45 6 7 1228 14.88 278 263 110 90
Nonpareil 4 7 45 6 1 1280 14.88 381 363 145 115
Ionic 4 7 45 4 1 1970 14.88 429 411 145 115
Caslon 4 7 45 4 7 1938 14.88 432 413 145 115
Minion 2 7 45 4 1 1970 20.58 594 571 195 155
Primer 2 7 45 4 7 1938 20.58 596 574 195 155
Century 2 7 45 2 7 3050 20.58 674 651 195 155
Corinthian 1/0 19 60 1/0 7 4752 20.58 1073 1036 265 205
Doric 2/0 19 60 2/0 7 5926 25.42 1342 1301 300 235

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 228
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Copper Quadruplex Service Drop Cable
600V

Application
Used to supply power, usually from a pole-mounted transformer, to the user's service head where
connection to the service entrance cable is made. Also suitable for installations for street lighting,
security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-
phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conduc-
tors and 90°C for cross-linked polyethylene (XLP) insulated conductors.

Specifications

MULTIPLEX CABLES
Meets or exceeds the following ASTM specifications:
• B-1 Hard-Drawn Copper Wire
• B-3 Soft or Annealed Copper Wire
• B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and
crosslinked polyethylene insulated conductors.

Construction
Conductors are concentrically stranded compressed soft copper insulated with either crosslinked
polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.

Notes:
• Code words for XLP insulated products are formed by adding "XLP" to the conventional polyethyl-
ene code words above (e.g. Atlanta/XLP).
• Ampacity figures for black insulation only. Based on conductor temperature of 75°C for polyethyl-
ene insulated conductors,90°C for XLP insulated conductors, ambient temperature of 40°C; 2
ft./sec. wind in sun.

Item # Phase Phase Phase Neutral Neutral Neutral Nominal Weight Weight Allowable Allowable
Conductor Conductor Conductor Messenger Messenger Messenger Lay /MFT /MFT Ampacities Ampacities
Size Stranding Cover Size Stranding Rated Length XLP Poly XLP Poly
AWG Thickness AWG Strength (in) (lb) (lb)
(mil) (lb)
Atlanta 6 7 45 6 1 1280 20.58 359 344 95 75
Tallahassee 6 7 45 6 7 1228 20.58 361 346 95 75
Richmond 4 7 45 4 1 1970 20.58 560 542 125 100
BatonRouge 4 7 45 4 7 1938 20.58 563 545 125 100
Jackson 2 7 45 2 1 3003 25.42 879 856 170 135
Seattle 2 7 45 2 7 3050 25.42 883 860 170 135
Nashville 1/0 19 60 1/0 7 4752 25.42 1405 1368 230 180
Lincoln 2/0 19 60 2/0 7 5926 29.97 1761 1720 265 205
Raleigh 3/0 19 60 3/0 7 7366 35.18 2209 2163 305 235
Denver 4/0 19 60 4/0 7 9154 35.18 2773 2721 350 270

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 229
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Aluminum Single Secondary Type URD Cable
600V

Applications
Directly buried or installed in ducts for 600V secondary distribution.

Construction
Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insu-
lation.

Standards

MULTIPLEX CABLES
Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications.
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
• B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
• B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
• Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of
ICEA S-105-692.
• “USE-2” per UL 854 available upon request.
Options
• Cable in Duct (CIC)
• Abrasion Resistant
Ampacity
90°C conductor temperature, 20°C ambient, RHO factor 90, 100% load factor for three conductor
triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the
National Electric Code, latest edition.

Item # Size AWG Stranding Insulation Outside Weight Ampacity Ampacity


or MCM Thickness Diameter /MFT Direct In Duct
(mil) (in) (lb) Burial
Princeton 6 7 60 .298 45 90 65
Mercer 4 7 60 .345 64 120 85
Clemson 2 7 60 .403 93 155 115
Kenyon 1 19 80 .522 148 200 150
Harvard 1/0 19 80 .482 122 175 130
Yale 2/0 19 80 .566 179 225 170
Tufts 3/0 19 80 .616 217 250 195
Beloit 4/0 19 80 .672 265 290 225
Hofstra 250 37 95 .748 317 320 250
Gonzaga 300 37 95 .801 371 355 280
Rutgers 350 37 95 .851 423 385 305
Emory 500 37 95 .979 579 465 370
Duke 600 61 110 1.086 701 510 410
Furman 700 61 110 1.155 804 550 440
Sewanee 750 61 110 1.188 855 580 470
Fordham 1000 61 110 1.337 1109 670 545

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 209
Copyright © 2018, American Wire Group, Inc. 201400921
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Aluminum Duplex Secondary Type URD Cable
600 V

Applications
Directly buried or installed in ducts for 600V secondary distribution.

Construction
Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insu-
lation.

Standards

MULTIPLEX CABLES
Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications.
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
• B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
• B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
• Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of
ICEA S-105-692.
• “USE-2” per UL 854 available upon request.
Options
• Cable in Duct (CIC)
• Abrasion Resistant
Ampacity
90°C conductor temperature, 20°C ambient, RHO factor 90, 100% load factor for three conductor
triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the
National Electric Code, latest edition.

Item # Phase Phase Phase Neutral Neutral Neutral Single Outside Weight Ampacity Ampacity
Conductor Conductor Conductor Size Stranding Insulation Phase Diameter /MFT Direct in Duct
Size Stranding Insulation AWG Thickness Conductor (in) Poly Burial
AWG Thickness (mil) (in) (lb)
(mil)
Bard 8 7 60 8 7 60 .262 .524 76 70 70
Claflin 6 7 60 6 7 60 .299 .596 91 95 70
Delgado 4 7 60 4 7 60 .345 .690 129 125 90
Everett 2 7 60 2 7 60 .403 .806 189 187 100

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 210
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Aluminum Triplex Secondary Type URD Cable
600 V

Applications
Directly buried or installed in ducts for 600V secondary distribution.

Construction
Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insu-
lation.

Standards

MULTIPLEX CABLES
Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications.
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
• B-786 “19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation.”
• B-901 “Compressed round stranded Aluminum Conductors using single input wire construction.”
• Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of
ICEA S-105-692.
• “USE-2” per UL 854 available upon request.
Options
• Cable in Duct (CIC)
• Abrasion Resistant
Ampacity
90°C conductor temperature, 20°C ambient, RHO factor 90, 100% load factor for three conductor
triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the
National Electric Code, latest edition.

Item # Phase Phase Phase Neutral Neutral Neutral Single Outside Weight Ampacity Ampacity
Conductor Conductor Conductor Size Stranding Insulation Phase Diameter /MFT Direct in Duct
Size Stranding Insulation AWG Thickness Conductor (in) Poly Burial
AWG Thickness (mil) (in) (lb)
(mil)
Erskine 6 7 60 6 7 60 .299 .646 143 95 70
Vassar 4 7 60 4 7 60 .345 .754 203 125 90
Stephens 2 7 60 4 7 60 .403 .842 264 165 120
Ramapo 2 7 60 2 7 60 .403 .874 294 165 120
Brenau 1/0 19 80 2 7 60 .522 1.064 408 215 160
Bergen 1/0 19 80 1/0 19 80 .522 1.133 465 215 160
Converse 2/0 19 80 1 19 80 .566 1.174 502 245 160
Hunter 2/0 19 80 2/0 19 80 .566 1.228 560 245 180
Hollins 3/0 19 80 1/0 19 80 .616 1.276 606 280 205
Rockland 3/0 19 80 3/0 19 80 .616 1.336 678 280 205
Sweetbriar 4/0 19 80 2/0 19 80 .672 1.389 739 315 240
Monmouth 4/0 19 80 4/0 19 80 .672 1.457 828 315 240
Pratt 250 37 95 3/0 19 80 .748 1.538 893 345 265
Wesleyan 350 37 95 4/0 19 80 .851 1.736 1166 415 320
Holyoke 500 37 95 300 37 95 .979 2.008 1607 495 395
Rider 500 37 95 350 37 95 .979 2.035 1663 495 395
Fairfield 750 61 110 500 37 95 1.188 2.0860 2304 615 525

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 211
Copyright © 2018, American Wire Group, Inc. 201400921
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Aluminum Quadruplex Secondary Type URD Cable
600 V

Applications
Directly buried or installed in ducts for 600V secondary distribution.

Construction
Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insu-
lation.

Standards

MULTIPLEX CABLES
Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications.
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
• B-786 “19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation.”
• B-901 “Compressed round stranded Aluminum Conductors using single input wire construction.”
• Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of
ICEA S-105-692.
• “USE-2” per UL 854 available upon request.
Options
• Cable in Duct (CIC)
• Abrasion Resistant
Ampacity
90°C conductor temperature, 20°C ambient, RHO factor 90, 100% load factor for three conductor
triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the
National Electric Code, latest edition.

Item # Phase Phase Phase Neutral Neutral Neutral Single Outside Weight Ampacity Ampacity
Conductor Conductor Conductor Size Stranding Insulation Phase Diameter /MFT Direct in Duct
Size Stranding Insulation AWG Thickness Conductor (in) Poly Burial
AWG Thickness (mil) (in) (lb)
(mil)
Tulsa 4 7 60 4 7/w 60 .345 .833 258 119 85
Dyke 2 7 60 4 7/w 60 .403 .938 346 153 115
Wittenberg 2 7 60 2 7/w 60 .403 .973 375 153 115
Notre Dame 1/0 19 80 2 7/w 60 .522 1.188 541 198 150
Purdue 1/0 19 80 1/0 19/w 80 .522 1.260 596 198 150
Syracuse 2/0 19 80 1 19/w 80 .566 1.316 664 225 170
Lafayette 2/0 19 80 2/0 19/w 80 .566 1.367 720 225 170
Swarthmore 3/0 19 80 1/0 19/w 80 .616 1.430 805 250 195
Davidson 3/0 19 80 3/0 19/w 80 .616 1.487 874 250 195
Wake Forest 4/0 19 80 2/0 19/w 80 .672 1.560 979 290 225
Earlham 4/0 19 80 4/0 19/w 80 .672 1.623 1066 290 225
Slippery Rock 350 37 95 4/0 19/w 80 .851 1.945 1544 385 305
Wofford 500 37 95 350 37/w 95 .851 2.348 2174 467 420
Windham 750 61 110 500 37/w 95 .979 2.850 2542 615 492

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 212
Copyright © 2018, American Wire Group, Inc. 20160603
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Aluminum Mobile Home Feeder Type URD
600 V

Application
Mobile Home Feeder Cable is mainly used for supplying the energy required within the mobile
home. The cable is designed for use at 600V or less and conductor temperatures not exceeding
90°C.

Construction
Quadruplexed type USE-2 or RHH or RHW-2 compact stranded AA-8000 Series aluminum alloy con-

MULTIPLEX CABLES
ductors. Insulation is sunlight-resistant Cross-linked Polyethylene (XLPE). Neutral is identified by
triple extruded white stripes and Grounding is identified by total green surface coating.

Marking
• Manufacturer's ID plus E FILE NUMBER (SIZE AWG) AA-8000 AL TYPE USE-2 OR RHH OR RHW-2
SUN-RES 600V XLPE (UL) plus YEAR OF MANUFACTURE.
• Sequential footage markings.
Installation
Suitable for direct burial or underground installations and in raceways.

Standards
Mobile Home Feeder cable meets or exceeds the following specifications:
• ASTM B800 and B801 or B836 as applicable.
• UL 44
• UL 854
• NEC requirements.
To determine correct ampacity by conductor size, please consult the National Electric Code, latest
edition.

Item # Phase Phase Phase Neutral Neutral Neutral Grounding Grounding Grounding Diameter Allowable
Conductor Conductor Conductor Size Conductor Conductor Conductor Conductor Conductor Complete Ampacity
Size Const. Diameter AWG Const. Diameter Size AWG Const. Diameter Cable
AWG (in) (in) (in) (in)
2-2-2-4 2 7 0.403 2 7 0.403 4 7 0.345 0.942 100
2-5-4-6 2 7 0.403 4 7 0.345 6 7 0.298 0.938 100
2/0-2/0-2/0-1 2/0 19 0.566 2/0 19 0.566 1 19 0.482 1.321 150
2/0-2/0-4-1 2/0 19 0.566 1 19 0.482 4 7 0.345 1.210 150
4/0-4/0-4/0-2/0 4/0 19 0.672 4/0 19 0.672 2/0 19 0.566 1.567 200
4/0-4/0-2/0-4 4/0 19 0.672 2/0 19 0.566 4 7 0.345 1.480 200

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 213
Copyright © 2018, American Wire Group, Inc. 20140924
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Packaging Information:
Duplex Service Drop
Aluminum Conductor

Code Aluminum Conductors Standard Packages


Word Phase Neutral Length Weight Reel
Size & Size & (ft) Poly XLP Size
Stranding Stranding (lb) (lb)
AAC Messenger
Collie 6-7 6-7 500 32 33 Coil

MULTIPLEX CABLES
2,800 179 185 NRC 30.18
Spaniel 4-7 4-7 500 48 50 Coil
2,000 192 198 NRC 30.18

ACSR Messenger
Shepherd 6-7 6-6/1 1,000 75 77 Coil
3,300 248 254 NRC 38.18
Terrier 4-7 4-6/1 500 58 59 Coil
2,000 230 234 NRC 30.18

Aluminum Alloy 6201-T81 Messenger


Vizsla 6-7 30580-7 500 34 35 Coil
2,800 190 196 NRC 30.18
Whippet 4-7 48690-7 500 52 53 Coil
2,000 206 210 NRC 30.18

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 214
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Packaging Information:
Triplex Service Drop
Aluminum Conductor

Code Aluminum Conductors Standard Packages Code Aluminum Conductors Standard Packages
Word Phase Neutral Length Weight Reel Word Phase Neutral Length Weight Reel
Size & Size & (ft) Poly XLP Size Size & Size & (ft) Poly XLP Size
Stranding Stranding (lb) (lb) Stranding Stranding (lb) (lb)
AAC Neutral Messenger AAAC-6201 Alloy Messenger
Patella 6-7 6-7 1,000 104 107 Coil Hippa 6-7 30580-7 500 54 56 Coil

MULTIPLEX CABLES
2,200 229 235 NRC 30.18 2,000 214 222 NRC 30.18
Oyster 4-7 4-7 500 77 79 Coil Prawn 4-1 48690-7 Soo 77 79 Coil
1,500 230 237 NRC 38.18 1,700 260 269 NRC 30.18
Clam 2-7 2-7 500 116 119 Coil Barnacle 4-7 48690-7 500 80 83 Coil
1,800 418 428 NRC 36.24 1,500 240 248 NRC 30.18
Murex 1/0-7 1/0-7 500 187 192 Coil Shrimp 2-7 77470-7 500 121 125 Coil
1,200 448 460 NRC 36.24 1,800 436 448 NRC 36.24
Purpura 1/0-19 1/0-7 500 185 190 Coil Gammarus 1/0-7 123300-7 500 195 200 Coil
1,200 444 456 NRC 36.24 1,200 468 480 NRC 36.24
Nassa 210-7 2/0-7 1,500 692 708 NRC 42.26 Leda 1/0-19 123300-7 500 193 198 Coil
Traphon 2/0-19 2/0-7 1,500 684 701 NRC 42.26 1,200 463 475 NRC 36.24
Quahog 3/0-7 3/0-7 1,300 741 758 NRC 42.26 Dungeness 2/0-7 155400-7 1,500 723 740 NRC 42.26
Melita 3/0-19 3/0-19 1,300 735 750 NRC 42.26 Cyclops 2/0-19 155400-7 1,500 716 732 NRC 42.26
Coquina 4/0-7 4/0-7 1,000 707 722 NRC 42.26 Stonecrab 3/0-7 195700-7 1,300 775 792 NRC 42.26
Portunus 4/0-19 4/0-19 1,000 699 713 NRC 42.26 Flustra 3/0-19 195700-7 1,300 768 784 NRC 42.26
Kingcrab 4/0-7 246900-7 1,000 740 755 NRC 42.26
ACSR Full Size Messenger Lepas 4/0-19 2469W-7 1,000 733 746 NRC 42.26
Voluta 6-7 6-6/1 1,000 115 118 Coil
2,200 253 260 NRC 30.18 Aluminum Alloy 6201-T81 Reduced Size Messenger
Periwinkle 4-7 4-6/1 500 86 88 Coil Crab 4-7 30580-7 500 72 74 Coil
1,500 238 264 NRC 30.18 1,500 215 222 NRC 30.18
Conch 2-7 2-6/1 500 131 134 Coil Solaster 2-7 48690-7 500 108 111 Coil
1,800 470 481 NRC 36.24 1,800 367 400 NRC 36.24
Neritina 1/0-7 1/0-6/1 500 210 215 Coil Sandcrab 1/0-7 77470-7 500 174 179 Coil
1,200 503 516 NRC 36.24 1,200 416 428 NRC 36.24
Cenia 1/0-19 1/0-6/1 500 208 213 Coil Echinus 1/0-19 77470-7 500 172 177 Coil
1,200 499 511 NRC 36.24 1,200 412 424 NRC 36.24
Runcina 210-7 2/0-6/1 1,500 779 795 NRC 42.26 Crayfish 2/0-7 97633-7 1,500 641 659 NRC 42.26
Triton 2/0-19 2/0-6/1 1,500 771 789 NRC 42.26 Sipho 2/0-19 97633-7 1,500 635 651 NRC 42.26
Cherrystone 3/0-7 3/0-6/1 1,300 836 853 NRC 42.26 Slub 3/0-7 123300-7 1,300 686 703 NRC 42.26
Mursia 3/0-19 3/0-6/1 1,300 829 845 NRC 42.26 Fulgar 310-19 123300-7 1,300 680 696 NRC 42.26
Razor 4/0-7 4/0-6/1 1,000 799 814 NRC 42.26 Squid 4/0-7 155400-7 1,000 654 669 NRC 42.26
Zuzara 4/0-19 4/0-6/1 1,000 792 806 NRC 42.26 Arca 4/0-19 155400-7 1,000 647 661 NRC 42.26
Limpet 336.4-19 336.4-18/1 1,000 1150 1180 NRC 42.26

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 215
Copyright © 2018, American Wire Group, Inc. 20140110
Packaging Information:
Triplex Service Drop
Aluminum Conductor

Code Aluminum Conductors Standard Packages


Word Phase Neutral Length Weight Reel
Size & Size & (ft) Poly XLP Size
Stranding Stranding (lb) (lb)
ACSR Reduced Size Messenger
Stombus 4-7 6-6/1 500 76 78 Coil
MULTIPLEX CABLES

1,500 228 233 NRC 30.18


Cockle 2-7 4-6/1 500 114 117 Coil
1,800 409 419 NRC 36.24
lanthina 1/0-7 2-6/1 500 183 188 Coil
1,200 438 451 NRC 36.24
Ranelia 1/0-19 2-6/1 500 181 186 Coil
1,200 434 446 NRC 36-24
Cavolinia 2/0-7 1-6/1 1,500 677 693 NRC 42.26
Clio 2/0-19 1-6/1 1,500 669 687 NRC 42.26
Sanddollar 3/0-7 1/0-6/1 1,300 724 741 NRC 42.26
Aega 3/0-19 1/0-6/1 1,300 718 735 NRC 42.26
Cuttlefish 4/0-7 2/0-6/1 1,000 691 706 NRC 42.26
Cerapus 4/0-19 2/0-6/1 1,000 684 699 NRC 42.26

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
215 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Packaging Information:
Quadraplex Service Drop
Aluminum Conductor

Code Aluminum Conductors Standard Packages Code Aluminum Conductors Standard Packages
Word Phase Neutral Length Weight Reel Word Phase Neutral Length Weight Reel
Size & Size & (ft) Poly XLP Size Size & Size & (ft) Poly XLP Size
Stranding Stranding (lb) (lb) Stranding Stranding (lb) (lb)
AAC Neutral Messenger AAAC-6201 Alloy Neutral Messenger
Pinto 4-7 4-7 500 106 109 Coil French Coach 6-7 30580-7 500 73 76 Coil

MULTIPLEX CABLES
1,500 317 327 NRC 36.24 2,000 290 302 NRC 36.24
Mustang 2-7 2-7 500 159 163 Coil Arabian 4-7 48690-7 500 109 112 Coil
1,800 571 587 NRC 42.26 1,500 326 336 NRC 36.24
Libyan 1/0-7 1/0-7 550 281 288 NRC 36.24 Belgian 2-7 77470-7 500 164 169 Coil
1,100 561 576 NRC 42.26 1,800 589 607 NRC 42.26
Criollo 1/0-19 1/0-7 550 278 286 NRC 36.24 Plow 110-7 123300-7 550 290 298 NRC 36.24
1,100 556 572 NRC 42.26 1,100 580 596 NRC 42.26
Orloff 2/0-7 210-7 750 472 485 NRC 36.24 Shetland 1/0-19 123300-7 550 287 295 NRC 36.24
1,500 944 969 NRC 50.32 1,100 574 591 NRC 42.26
Percheron 2/0-19 2/0-7 750 467 479 NRC 36.24 Dapple-Grey 2/0-7 155400-7 750 488 500 NRC 36.24
1,500 933 959 NRC 50.32 1,500 975 1001 NRC 50.32
Mongolian 310-7 3/0-7 650 504 517 NRC 36.24 Thoroughbred 2/0-19 155400-7 750 482 495 NRC 36.24
1,300 1009 1034 NRC 50.32 1,500 965 990 NRC 50.32
Hanoverian 3/0-19 3/0-19 650 499 512 NRC 36.24 Dobbin 3/0-7 195700-7 650 521 534 NRC 36.24
1,300 998 1,023 NRC 50.32 1,300 1,043 1,069 NRC 50.32
Singlefoot 4/0-7 4/0-7 500 481 492 NRC 40.24 Trotter 3/0-19 195700-7 650 516 528 NRC 36.24
1,000 961 983 NRC 50.32 1,300 1,032 1,057 NRC 50.32
Oldenberg 4/0-19 4/0-19 500 475 486 NRC 40.24 Pony 4/0-7 246900-7 500 497 508 NRC 40.24
1,000 950 971 NRC 50.32 1,000 994 1,016 NRC 50.32
Walking 4/0-19 246900-7 500 492 502 NRC 40.24
ACSR Messenger 1,000 983 1004 NRC 50.32
Chola 6-7 6-6/1 500 77 80 Coil
2,100 322 334 NRC 36.24
Hackney 4-7 4-6/1 500 115 118 Coil
1,500 344 354 NRC 36.24
Palornino 2-7 2-6/1 500 173 178 Coil
1,800 623 639 NRC 42.26
Standardbred 1/0-7 1/0-6/1 550 306 315 NRC 36.24
1,100 612 629 NRC 42.26
Costena 1/0-19 110-6/1 550 303 311 NRC 36.24
1,200 606 623 NRC 42.26
Chicoteagues 2/0-7 2/0-6/1 750 515 528 NRC 36.24
1,500 1031 1056 NRC 50.32
Grullo 2/0-19 210-6/1 750 510 523 NRC 36.24
1,500 1,020 1,046 NRC 50.32
Mare 3/0-7 310-6/1 650 522 565 NRC 36.24,
1,300 1,104 1,130 NRC 50.32
Suffolk 3/0-19 3/0-6/1 650 547 559 NRC 36.24
1,300 1,093 1,118 NRC 50.32
Stallion 4/0-7 4/0-6/-l 500 527 538 NRC 40.24
1,000 1,053 1,075 NRC 50.32
Appaloosa 4/0-19 4/0-16/1 500 521 532 NRC 40.24
1,000 1,042 1,063 NRC 50.32
Bronco 336.4-19 336.4-18/1 1,000 1510 1587 NRC 50.32

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 216
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Packaging Information:
Secondary
Type URD Cable

Code Aluminum Conductor Standard Packages Code Aluminum Conductor Standard Packages
Word Size Stranding Length Weight Reel Word Size Stranding Length Weight Reel
AWG or (ft) (lb) Size AWG or (ft) (lb) Size
Cir. Mils Cir. Mils

Single Conductor Type URD Cable Triplex Conductor Type URD Cable
Clemson 2 7 1,000 98 NRC 24.12 Stephens 2-7 4-7 1,000 262 NRC 32.24

MULTIPLEX CABLES
7,000 686 NRC 36.24 Brenau 1/0-19 2-7 1,000 409 NRC 36.24
Kenyon 1 19 1,000 131 NRC 24.12 Converse 2/0-19 1-19 1,000 504 NRC 40.24
5,000 655 NRC 36.24 Hollins 3/0-19 1/0-19 1,000 609 NRC 42.26
Harvard 1/0 19 1,000 157 NRC 24.12 Sweetbriar 4/0-19 2/0-19 1,000 740 NRC 42.26
5,000 785 NRC 40.24 Pratt 250000-37 3/0-19 1,000 896 NRC 50.32
Yale 210 19 1,000 189 NRC 24.18 Wesleyan 350000-37 4/0-19 1,000 1,168 NRC 50.32
5,500 1,040 NRC 42.26 Rider 500000-37 350000-37 1,000 1,606 NRC 58.32
Tufts 3/0 19 1,000 229 NRC 24.18
4,800 1,100 NRC 42.26 Triplex Conductor Type URD Cable
Beloit 4/0 19 1,000 278 NRC 24.18 Ramapo 2 2-7 1,000 291 NRC 32.24
1,000 278 NRC 30.15 Bergen 1/0 1/0-19 1,000 465 NRC 40.24
4,100 1,140 NRC 42.26 Hunter 210 2/0-19 1,000 561 NRC 40.24
Hoistra 250000 37 1,000 336 NRC 30.18 Rockland 3/0 3/0-19 1,000 680 NRC 42.26
Rutgers 350000 37 1,000 448 NRC 32.24 Monmouth 4/0 4/0-19 1,000 827 NRC 45.28
Emory 500000 37 1,000 611 NRC 36.24 Also available master reel lengths up to 20,000 ft. We custom cut to any
length you need.
Sewanee 750000 61 1,000 902 NRC 40.24
Fordham 1000000 61 1,000 1,166 NRC 42.26

Quadruplex Conductor Type URD Cable


Tulsa 4-7 4-7 1,000 258 NRC 32.24
1,500 387 NRC 34.26
Dyke 2-7 4-7 1,000 346 NRC 32.24
1,400 484 NRC 40.24
1,500 519 NRC 40.24
Wittenberg 2-7 2-7 1,000 375 NRC 32.24
1,400 525 NRC 40.24
1,500 563 NRC 40.24
Notre Dame 1/0-19 2-7 1,000 541 NRC 40.24
1,400 757 NRC 48.28
1,500 812 NRC 48.28
Purdue 1/0-19 1/0-19 1,000 596 NRC 42.26
1,400 834 NRC 48.28
1,500 894 NRC 48.28
Syracuse 2/0-19 1-19 1,000 664 NRC 42.26
1,400 930 NRC 50.32
1,500 996 NRC 50.32
Lafayette 2/0-19 2/0-19 1,000 720 NRC 42.28
Wake Forest 4/0-19 2/0-19 1,000 979 NRC 50.32
1,400 1371 NRC 54.32
1,500 1469 NRC 54.32
Farlham 4/0-19 4/0-19 1,000 1066 NRC 50.32
1,500 1599 NRC 54.32
Slippery Rock 350-37 4/0-19 1,000 1544 NRC 60.28
1,400 2162 NRC 66.28

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 217
Copyright © 2018, American Wire Group, Inc. 20140902
NOTES
MULTIPLEX CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
LOW VOLTAGE CABLES
Table of Contents

TowerGuard CCA® 2kV RHH or RHW-2 ................................................................................201


Aluminum HYLUG™ Terminal and HYLINK™ Splice Connectors .....................................242
Aluminum XLP UL XHHW-2 90° 600V..................................................................................205
Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 600V .........................................................204
TowerGuard® Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 2kV....................................202
Towerguard Plus® Class 33 Aluminum XLPE 105°C 2kV ....................................................240
SunGuardTM Aluminum XLPE UL Type PV Photovoltaic Wire 600V ..................................230
SunGuardTM Aluminum XLPE UL Type PV Photovoltaic Wire 2kV
PHYSICAL & ELECTRICAL PROPERTIES ..............................................................................225
SunGuardTM Duplexed Aluminum XLPE UL Type PV Photovoltaic Wire 2kV....................234
SunGuard™ Paralleled Aluminum XLPE UL Type PV Photovoltaic Wire 2kV ...................243

LOW VOLTAGE CABLES


Copper PVC UL THW-2 75°C 600V ........................................................................................219
Copper PVC UL TFFN/TFN 90°C 600V...................................................................................226
Copper PVC/Nylon UL THHN/THWN-2 90°C Dry 75°C Wet 600V ........................................218
UF-B Underground Feeder 600V ..........................................................................................220
Copper XLP UL XHHW-2 600V..............................................................................................222
Copper XLP Type SIS VW-1 90°C 600V ................................................................................221
Copper XLP UL RHH/RHW-2 or USE-2 90°C 600V...............................................................223
SunGuardTM Copper XLPE UL Type PV Photovoltaic Wire 600V ........................................203
Copper EPR/CPE UL RHH/RHW-2 or USE-2 90°C 600V .......................................................224
Copper XLP UL RHH/RHW-2 or USE-2 90°C 2kV .................................................................233
DLO Copper EPR/CPE UL TRJJ/RHW-2 2kV..........................................................................709
SunGuardTM Copper XLPE Type PV Photovoltaic Wire 2kV ...............................................231
LSZH XLPO/LSZH XLPO UL Type RHH/RHW-2/USE-2 Unshielded 600V ...........................241
SunGuardTM Tracker Motor Cable UL Type PV/TC 2kV ........................................................239

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 200
Copyright © 2018, American Wire Group, Inc. 20180201
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
TowerGuard CCA® Power Cable
2kV UL RHH/RHW-2 Copperclad Aluminum Conductor/90°C Wet or Dry
For Cable Tray Use — Sunlight Resistant — For Direct Burial
U.S. Patent No. 8,618,688

Applications Specifications
This cable is intended for fixed installation in • ICEA S-95-658 / NEMA WC70
wind turbine towers. Good resistance to temper- • UL Standard 44
atures, oils, ozone and fire. This cable is in- • ASTM B 566
tended for use in solar power generation • ASTM B 172
applications to connect the inverter to trans-
former where high flexibility is required, com- Product Features
monly applied to prefabricated inverter and • 35% less expensive than copper cables with
transformer skids. Additionally, this cable is ap- equal ampacity
propriate for tight battery applications, as well • Flexible cable design — TowerGuard RHH or
as superior alternatives to battery cable. Tower- RHW-2 can bend to a radius of 6 times the
Guard CCA can also be used for secondary volt- O.D. without impairing the insulation.
age resistance welding leads and in power • Surface printed for easy identification
supply applications not exceeding 2000V volts. • 35% lighter weight and easier to install than
Not commonly for use on DC power circuits, copper cables with equal ampacity
please consult AWG for your applications. • Ozone, sunlight, oil, grease, weather, water,

LOW VOLTAGE CABLES


chemical and abrasion resistant jacket
Construction • 90°C (dry) 90°C (wet)
Nominal voltage: RHH/RHW-2 2000V UL • No scrap value (theft deterrent)
Conductor: The conductor shall be a flexible • Sequential footage markers
Copperclad Aluminum (CCA), an electrical con- • U.S. Patent No. 8,618,688
ductor that has an outer sleeve of copper metal- Terminals and Splices
lurgically bonded to a solid aluminum core. The Testing has been competed using TowerGuard
combination of these two metals makes it CCA with BURNDY® aluminum HYLUGTM termi-
uniquely suited to many electrical applications nals an HYLINKTM splices. Both are UL Listed
where weights to electrical conductivity issues for use on copperclad aluminum cable.
are important. This bimetallic wire is much
lighter than copper and only slightly heavier
than bare aluminum. The density of CCA is Wire Size BURNDY LUG PART NUMBER
about 35% lighter than copper. CCA conducts 1 hole 2 hole Butt
like copper for AC frequencies. This product Splice
meets or exceeds the minimum requirements CCA4/0 4/0awg YA30A1 YA30A3 YS30A1
set forth in ASTM B 566 04. CCA250 250kcmil YA31A1 YA31A3 YS31A1
Separator: A suitable tape separator between CCA350 350kcmil YA34A1 YA34A3 YS34A1
the conductor and insulation. CCA500 500kcmil YA36A1 YA36A3 YS36A1
Insulation: Ethylene-propylene rubber (EPR) CCA600 600kcmil YA39A1 YA39A5 YS39A1
type EP, meeting UL and ICEA requirements for CCA750 750kcmil YA44A1 YA44A3 YS44A1
90ºC.
CCA800 750kcmil YA44A1 YA44A3 YS44A1
Jacket: A heavy duty, thermosetting CPE in ac-
cordance with ICEA S-95-658 NEMA WC70 CCA900 900kcmil YA45A5 YS45A1
Jacket Color: Black CCA1000 1000kcmil YA45A5 YS45A1
Print Legend: TOWERGUARD CCA SIZE AWG
OR KCMIL) CU CLAD AL UL 217923 RHH or
RHW-2 2000V SUN RES OIL RES U.S. Patent No.
8,618,688 (SEQUENTIAL FOOTAGE MARKER)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 201
Copyright © 2018, American Wire Group, Inc. 201400924
NOTES

Item # Conductor Stranding Nominal Nominal Nominal Nominal Copper Aluminum Net Ampacity* Ampacity**
Size Conductor Insulation Jacket Cable Weight Weight Cable 90°C 90°C
AWG/kcmil Diameter Thickness Thickness Diameter /MFT /MFT Weight Free Air Duct
(in) (mil) (mil) (in) (lb) (lb) /MFT
(lb)
CCA4/0-01TWRGRD 4/0 329 0.584 65 45 0.802 96 165 458 315 205
CCA250-01TWRGRD 250 399 0.650 75 65 0.930 116 200 590 355 230
CCA350-01TWRGRD 350 551 0.764 75 65 1.044 161 277 756 455 280
CCA500-01TWRGRD 500 779 0.909 75 65 1.189 227 391 1017 545 350
CCA600-01TWRGRD 600 925 0.993 90 65 1.273 270 464 1301 615 385
CCA750-01TWRGRD 750 1184 1.124 90 65 1.434 345 595 1462 700 435
CCA800-01TWRGRD 800 1258 1.158 90 65 1.468 367 632 1521 725 450
CCA900-01TWRGRD 900 1406 1.225 90 65 1.535 416 706 1733 785 480
CCA1000-01TWRGRD 1000 1554 1.288 90 65 1.598 453 780 1850 845 500
LOW VOLAGE CABLES

*Ampacity is calculated based on a single conductor in free air with a 90°C conductor temperature and 30°C ambient, per 2008 NEC, Table 310-17
**Ampacity is calculated based on 3 conductors in a duct with a 90°C conductor temperature and 30°C ambient, per 2008 NEC, Table 310-16

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
201 Information on this sheet subject to change without notice.
201400924 Copyright © 2018, American Wire Group, Inc.
Aluminum HYLUG™ Terminal and
® Listed Wire HYLINK™ Splice Connectors
Connector Types YA-A and YS-A, 90°C, up to 35 kV

1. Use a HYLUG™ termi- 2.Strip the wire insulation 3. Always wire brush the 4.Insert the conductor all 5.Wire brush any un-
nal or HYLINK™ splice without nicking or ring- stripped portion of the the way into the barrel plated surface to which
marked for the wire size ing the conductor conductor to remove and crimp the connec- the HYLUG™ will be at-
to be used. Never use a strands. oxide film. tor using a die index tached and coat the
copper crimp connector number and color contact surface with

LOW VOLTAGE CABLES


on aluminum wire. marked on the connec- PENETROX™ joint com-
tor. Be sure orientation pound.
is correct before crimp-
ing. 6.Remove any excess
PENETROX™ before
• Dieless tools and nest/indenter tools • Other die sets listed have a completed taping.
will have a completed crimp similar crimp of a more circumferential nature
to illustration shown. and will look similar to this illustration.

Catalog # Conductor Color Die BUNDY® Installation Tooling (# Crimps) Wire


HYLUGTM HYLINKTM Size Code Information Mechanical Hydraulic Dieless Strip
Terminal Splice Al or CU Die Die OUR840 MD6 Y35 Y46(1) Y45(1) Y60 Mechanical Hydraulic Length
Concentric Index Type PATMD6 Y39 PAT46(1)
Compressed PAT600 Y750
Compact PAT750
YA8CA- YS8CA- 8 AWG BLUE 374 DIE SET X8CART(2) W374(1) U8CABT(1) U8CABT(1) U8CABT(1) - MRC840AL(1) PAT644(1) 3/4”
MY29-3(1) Y644(1)
PAT81KFT(1)
Y81KFT(1)
YA6CA- YS6CA- 6 AWG GRAY 346 DIE SET X6CART(2) - U6CABT(1) U6CABT(1) U6CABT(1) - MRC840AL(1) PAT644(1) 7/8”
161 X161(2) W161(1) U161(1) U161(1) U161(1) - MY29-3(1) Y644(1)
PAT81KFT(1)
Y81KFT(1)
YA4CA- YS4CA- 4 AWG GREEN 375 DIE SET X4CART(3) - U4CABT(1) U4CABT(1) U4CABT(1) - MRC840AL(2) PAT644(1) 1”
162 - W162(3) U162(1) U162(1) U162(1) - MY29-3(1) Y644(1)
PAT81KFT(1)
Y81KFT(1)
YA2CA- YS2CA- 2 AWG PINK 348 DIE SET X2CART(4) - U2CAB(1) U2CABT(1) U2CABT(1) - MRC840AL(2) PAT644(1) 1-1/4”
163 - W163(3) U163(1) U163(1) U163(1) - MY29-3(2) Y644(1)
239 X239(4) W239(2) U239(1) U239(1) U239(1) - PAT81KFT(2)
Y81KFT
YA1CA- YS1CA- 1 AWG GOLD 371 DIE SET X1CART(3) - U1CART(1) U1CART(1) U1CART(1) - MRC840AL(2) PAT644(1) 1-1/16”
163 - W163(3) U163(1) U163(1) U163(1) - MY29-3(2) Y644(1)
PAT81KFT(2)
Y81KFT(2)
① Catalog # PUADP-1 Adaptor is required to use "U" dies in Y46 series tools
② Catalog # PT6515 Adaptor is required to use "U" dies in Y45 series tools
③ CCA DLO Conductor to be installed with Y644/PAT644 series of tools only

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 242
Copyright © 2018, American Wire Group, Inc. 20170318
Aluminum HYLUG™ Terminal and
HYLINK™ Splice Connectors
Types YA-A and YS-A, 90°C, up to 35 kV

Catalog # Conductor Color Die BUNDY® Installation Tooling (# Crimps) Wire


HYLUGTM HYLINKTM Size Code Information Mechanical Hydraulic Dieless Strip
Terminal Splice Al or CU Die Die OUR840 MD6 Y35 Y46(1) Y45(1) Y60 Mechanical Hydraulic Length
Concentric Index Type PATMD6 Y39 PAT46(1)
Compressed PAT600 Y750
Compact PAT750
YA25A- YS25A- 1/0 AWG TAN 296 DIE SET X25ART(4) - U25ART(1) U25ART(1) U25ART(1) - MRC840AL(2) PAT644(1) 1-3/16”
241 X241(4) W241(2) U241(1) U241(1) U241(1) - MY29-3(2) Y644(1)
PAT81KFT(2)
Y81KFT(2)
YA26A- YS26A- 2/0 AWG OLIVE 297 DIE SET X26ART(4) - U26ART(2) U26ART(2) U26ART(2) - MRC840AL(3) PAT644(1) 1-3/8”
245 X245(4) W245(3) U245(1) U245(1) U245(1) - MY29-3(2) Y644(1)
PAT81KFT(2)
Y81KFT(2)
YA27A- YA27A- 3/0 AWG RUBY 467 DIE SET X27ART(4) - U27ART(2) U27ART(2) U27ART(2) - MRC840AL(3) PAT644(1) 1-1/2”
LOW VOLAGE CABLES

166 - W166(4) U166(2) U166(2) U166(2) - MY29-3(2) Y644(1)


PAT81KFT(2)
Y81KFT(2)
467 NEST - - - P30D(1) - - -
INDENTOR - - - P34PR-5 - - -
YA28A- YS28A- 4/0AWG WHITE 298 DIE SET X28ART(6) - U28ART2 U28ART(2) U28ART(2) - MRC840AL(3) PAT644(1) 1-5/8”
660 X660(8) W660(3) U6602 U660(2) U660(2) - MY29-3(2) Y644(1)
PAT81KFT(2)
Y81KFT(2)
298 NEST - - - P31D(1) - - -
INDENTOR - - - P34PR-5 - - -
YA29A- YS29A- 250 kcmil RED 324 DIE SET - - U29ART(2) U29ART(2) U29ART(2) L29ART(1) - PAT644(1) 1-5/8”
Y644(1)
PAT81KFT(2)
Y81KFT(2)
NEST - - - P32D(1) - - -
INDENTOR - - - P34PR-5
YA30A- YS30A- 300 kcmil BLUE 470 DIE SET - - U30ART(2) U30ART(2) U30ART(2) L30ART(1) - PAT644(1) 1-3/4”
(4/0AWG Y644(1)
CCA DLO③ PAT81KFT(2)
[329/22]) Y81KFT(2)
NEST - - - P34D(1) - - -
INDENTOR - - - P48PR-1 - - -
YA31A- YS31A- 350 kcmil BROWN 299 DIE SET - - U31ART(2) U31ART(2) U31ART(2) - - PAT644(1) 2-1/8”
(250 kcmil Y644(1)
CCA DLO③ PAT81KFT(3)
[399/22]) Y81KFT(3)
NEST - - - - P35D(1) - -
INDENTOR - - - - P48PR-1 - -
YA32A- YS32A- 400 kcmil GREEN 472 DIE SET - - U32ART(4) U32ART(4) U32AR(2) L32ART(2) - PAT644(1) 2-1/2”
Y644(1)
PAT81KFT(4)
Y81KFT(4)
NEST - - - P35D(1) - - -
INDENTOR - - - P48PR-1 - - -
YA34A- YS34A- 500 kcmil PINK 300 DIE SET - - U34ART(4) U34ART(4) U34ART(4) L34ART(2) - PAT644(1) 2-5/8”
(350 kcmil Y644(1)
CCA DLO③ PAT81KFT(4)
[551/22]) Y81KFT(4)
NEST - - - P39D(1) - - -
INDENTOR - - - P48PR-1 - - -
① Catalog # PUADP-1 Adaptor is required to use "U" dies in Y46 series tools
② Catalog # PT6515 Adaptor is required to use "U" dies in Y45 series tools
③ CCA DLO Conductor to be installed with Y644/PAT644 series of tools only

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
242 Information on this sheet subject to change without notice.
20170318 Copyright © 2018, American Wire Group, Inc.
Aluminum HYLUG™ Terminal and
HYLINK™ Splice Connectors
Types YA-A and YS-A, 90°C, up to 35 kV

Catalog # Conductor Color Die BUNDY® Installation Tooling (# Crimps) Wire


HYLUGTM HYLINKTM Size Code Information Mechanical Hydraulic Dieless Strip
Terminal Splice Al or CU Die Die OUR840 MD6 Y35 Y46(1) Y45(1) Y60 Mechanical Hydraulic Length
Concentric Index Type PATMD6 Y39 PAT46(1)
Compressed PAT600 Y750
Compact PAT750
YA36A- YS36A- 600 kcmil BLACK 473 DIE SET - - U36ART(4) U36ART(4) U36ART(4) L36ART(2) - PAT644(1) 2-7/8”
(500 kcmil Y644(1)
CCA DLO③ PAT81KFT(4)
[779/22] Y81KFT(4)
NEST - - - P44D(2) - - -
INDENTOR - -- - P48PR-1 - - -
YA39A- YS39A- 700/750 kcmil YELLOW 936 DIE SET - - U39ART-2(4) U39ART-2(4) U39ART-2(4) L39ART-2(2) - PAT644(1) 2-7/8”
(600 kcmil Y644(1)
CCA DLO③ PAT81KFT(4)

LOW VOLTAGE CABLES


[925/22]) Y81KFT(4)
YA39AM- YS39AM- 700 kcmil RED 301 DIE SET - - - P39ART(4) S39ART(4) L39ART(2) - PAT644(1) 2-7/8”
or 750 kcmil Y644(2)
NEST - - - P45D(2) - - - PAT81KFT(4)
INDENTOR - - - P48PR-1 - - - Y81KFT(4)
YA40A- YS40A- 800 kcmil GRAY 474 DIE SET - - - P40ART(4) S40ART(4) L40ART(2) - Y644MBH(1) 3”

NEST - - - P45D(4) - - -
INDENTOR P48PR-1 - - -
YA42A- YS42A- 900 kcmil GRAY 303 DIE SET - - U42ART(4) U42ART(4) U42ART(4) - - PAT644(2) 2-7/8”
ALUMINUM Y644(2)
ONLY
YA44A- YS44A- 1000 kcmil BROWN 302 DIE SET - - - P44ART(4) S44ART(4) L44ART(2) - Y644MBH 3-1/8”
(750/800 kcmil ONLY
CCA DLO③ (1)
[1184/1258]) NEST NO NEST
INDENTOR - - - P48PR-1(2) - - -
YA45A- YS45A- 1250 kcmil BROWN 302 DIE SET - - - P44ART(4) S44ART(4) L44ART(2) - Y644MBH 3-1/8”
(900/1000 kcmil ONLY
CCA DLO③ (1)
[1406/1554]) NEST NO NEST
INDENTOR - - - P48PR-1(2) - - -
YA46A- YS46A- 1500 kcmil BLUE 478 DIESET - - - - - L46ART(2) - - 3-3/4”
YA47A- YS47A- 1750 kcmil WHITE 587 DIESET - - - - - L47ART(2) - - 4-3/8”
YA48A- YS48A- 2000 kcmil RED 479 DIESET - - - - - L48ART(2) - - 4-1/8”

① Catalog # PUADP-1 Adaptor is required to use "U" dies in Y46 series tools
② Catalog # PT6515 Adaptor is required to use "U" dies in Y45 series tools
③ CCA DLO Conductor to be installed with Y644/PAT644 series of tools only

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 242
Copyright © 2018, American Wire Group, Inc. 20170318
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
20X Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Aluminum XLP UL
XHHW-2 600V
90°C Wet or Dry

Applications
Type XHHW-2 is intended for use as general purpose wiring in air conduit or other recognized race-
ways for services, feeder and branch circuit wiring as specified in the National Electric Code at a
maximum conductor temperature of 90°C in wet or dry locations.

Construction
Compact stranded 8000 Series aluminum alloy conductor, black abrasion, heat and moisture resist-
ant cross-linked polyethylene insulation.

Standards
• UL 44
• Federal specifications JC-30B NEC, ASTM B 800, B 801, B 836 as applicable.
Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, latest
edition.

LOW VOLTAGE CABLES


Item # Size AWG Stranding Insulation Outside Weight Ampacity
or MCM Thickness Diameter /MFT 90°C
(mil) (in) (lb)
XHHW-2-0008 8 7 45 .230 29 45
XHHW-2-0006 6 7 45 .260 40 60
XHHW-2-0004 4 7 45 .305 58 75
XHHW-2-0002 2 7 45 .360 86 100
XHHW-2-0001 1 18 55 .415 109 115
XHHW-2-01/0 1/0 18 55 .450 132 135
XHHW-2-02/0 2/0 18 55 .490 162 150
XHHW-2-03/0 3/0 18 55 .540 199 175
XHHW-2-04/0 4/0 18 55 .590 245 205
XHHW-2-0250 250 35 65 .655 294 230
XHHW-2-0300 300 35 65 .705 347 255
XHHW-2-0350 350 35 65 .750 398 280
XHHW-2-0400 400 35 65 .795 450 305
XHHW-2-0500 500 35 65 .870 552 350
XHHW-2-0600 600 58 80 .980 672 385
XHHW-2-0700 700 58 80 1.040 774 420
XHHW-2-0750 750 58 80 1.075 825 435
XHHW-2-1000 1000 58 80 1.230 1077 500

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 205
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Aluminum XLP UL
RHH/RHW-2 or USE-2 600V
90°C Wet or Dry

Applications
Type RHH-RHW-2 or USE-2 building wire and service cable is recognized for use as general purpose
wiring at a maximum conductor temperature of 90°C in wet or dry locations for installation in air,
conduit or other recognized raceways and for direct burial in circuits not exceeding 600V.

Construction
Compact stranded 8000 Series aluminum alloy conductor, black abrasion, heat, moisture and sun-
light resistant cross-linked polyethylene insulation.

Standards
• UL Standards 44 (RHW or RHH)
• UL standard 854 (USE-2)
• Federal specification JC-30B NEC
• ASTM B800, B801, B836 as applicable.
Ampacity

LOW VOLTAGE CABLES


To determine correct ampacity by conductor size, please consult the National Electric Code, latest
edition.

Item # Size AWG Stranding Insulation Outside Weight Ampacity


or MCM Thickness Diameter /MFT 90°C
(mil) (in) (lb)
USE-RHH-RHW-2-0008 8 7 60 .266 37 45
USE-RHH-RHW-2-0006 6 7 60 .290 49 60
USE-RHH-RHW-2-0004 4 7 60 .334 65 75
USE-RHH-RHW-2-0002 2 7 60 .390 94 100
USE-RHH-RHW-2-0001 1 18 80 .460 125 115
USE-RHH-RHW-2-01/0 1/0 18 80 .500 150 135
USE-RHH-RHW-2-02/0 2/0 18 80 .540 181 150
USE-RHH-RHW-2-03/0 3/0 18 80 .590 220 175
USE-RHH-RHW-2-04/0 4/0 18 80 .635 268 205
USE-RHH-RHW-2-0250 250 35 95 .710 320 230
USE-RHH-RHW-2-0300 300 35 95 .760 374 255
USE-RHH-RHW-2-0350 350 35 95 .810 428 280
USE-RHH-RHW-2-0400 400 35 95 .850 482 305
USE-RHH-RHW-2-0500 500 35 95 .930 591 350
USE-RHH-RHW-2-0600 600 58 110 1.035 715 385
USE-RHH-RHW-2-0700 700 58 110 1.100 821 420
USE-RHH-RHW-2-0750 750 58 110 1.130 873 435
USE-RHH-RHW-2-1000 1000 58 110 1.280 1132 500

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 204
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
TowerGuard® Aluminum XLP UL
RHH/RHW-2 or USE-2 2kV
90°C

Applications Compliances
• For use from the lower control box at the base • National Electric Code (NEC)
of the wind power tower and out to the step- • UL 44 Stranded for rubber-insulated wires and
up transformer through conduit cables
• General purpose building wire for use in air • “CT” for 1/0 AWG and larger in accordance
and approved raceways with NEC
• Industrial environments where superior insu- • ICEA S-95-685/NEMA WC70
lation toughness and chemical resistance is • UL listed as Type RHH/RHW-2
required • OSHA acceptable
• Maximum operating temperature not to ex-
ceed 90°C in wet or dry locations Features
• For use in free air, raceways or direct burial in • Rated at 90°C wet or dry
accordance with NEC. • UV resistant — black is marked SR
• Excellent electrical, thermal and physical
Product Construction properties
Conductor: • Excellent resistance to moisture

LOW VOLTAGE CABLES


• 8 AWG thru 1000 kcmil compacted aluminum • Excellent resistance to crush, compression
ACM (AA-8000 Series) cuts and heat deformation
Insulation: Packaging
• Flame-retardant Cross-Linked Polyethylene • All produced or cut-to-order material will be
(XLPE) — Black shipped on non-returnable wooden reels un-
less specifically requested
Print: • Cable is stocked in 3 colors - Black with 3 Red
• TOWERGUARD XLP AWG/KCMIL TYPE Stripes, Black with 3 Yellow Stripes, Black with
RHH/RHW-2 SR CT (UL) 2000V (MM/YYYY) 3 Orange Stripes.
SEQUENTIAL FOOTAGE MARK
• Sizes smaller than 1/0 AWG do not include the
“CT” marking

Item # Conductor No. of Conductor Insulation Cable Aluminum Net Ampacity


Size Wires1 Diameter Thickness Diameter Weight Weight 90°C
AWG/kcmil (in) (mil) (in) /MFT /MFT
(lb) (lb)
TGXL-08 8 7 0.134 70 0.285 16 38 45
TGXL-06 6 7 0.169 70 0.320 25 51 60
TGXL-04 4 7 0.213 70 0.360 39 72 75
TGXL-02 2 7 0.268 70 0.420 62 100 100
TGXL-01 1 18 0.299 90 0.495 79 134 115
TGXL-1/0 1/0 18 0.336 90 0.530 99 160 135
TGXL-2/0 2/0 18 0.376 90 0.580 125 192 150
TGXL-3/0 3/0 18 0.423 90 0.615 158 229 175
TGXL-4/0 4/0 18 0.475 90 0.665 199 281 205
TGXL-250 250 35 0.520 105 0.745 235 336 230
TGXL-350 350 35 0.616 105 0.840 329 449 280
TGXL-500 500 35 0.736 105 0.960 471 605 350
TGXL-600 600 58 0.813 120 1.075 565 736 385
TGXL-750 750 58 0.908 120 1.175 706 901 435
TGXL-1000 1000 58 1.060 120 1.325 941 1168 500
Dimensions and weights are nominal; subject to industry tolerances.
1Minimum number of wires utilized for compact-strand constructions.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 202
Copyright © 2018, American Wire Group, Inc. 20151123
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Towerguard Plus®
Class 33 Aluminum XLPE 105°C 2kV

Applications Standards
• For use from the lower control box at the base • UL 1581
of the wind power tower and out to the step- • ICEA S-95-685/NEMA WC70
up transformer through conduit • CSA standard C 22.2 No. 38
• General purpose building wire for use in air
and approved raceways Features
• Industrial environments where superior insu- • Rated at 105 ºC wet or dry
lation toughness and chemical resistance is • UV resistant - black is marked SR
required • Smaller cable O.D.
• Maximum operating temperature not to ex- • Excellent electrical, thermal and physical
ceed 105 ºC in wet or dry locations properties
• For use in free air, raceways or direct burial in • Excellent resistance to moisture
accordance with NEC. • Excellent resistance to crush, compression
cuts and heat deformation
Construction
Conductor: 8 AWG thru 1000 kcmil compacted Packaging

LOW VOLTAGE CABLES


aluminum ACM (AA-8000 Series) Conductor. In- • Material can be produced and cut to length
sulation is Class 33 Flame-retardant Cross- upon request
Linked Polyethylene (XLPE) Black. • All produced or cut-to-order material will be
shipped on non-returnable wooden reels un-
Colors: Black, Red, Blue, Green, Orange, Yellow less specifically requested
Brown. 3 extruded stripes and other colors are
available upon request.
Print Legend:TOWERGUARD PLUS®
AWG/KCMIL AL XLPE 2000V 105 ºC (MM/YYYY)
SEQUENTIAL FOOTAGE MARK

Item # Conductor Number of Conductor Insulation Cable Aluminum Net


Size Wires1 Diameter Thickness Diameter Weight Weight
AWG or kcmil (in) (mil) (in) (lb/MFT) (lb/MFT)
A4/0-01XLP2BLK105 4/0 18 0.475 90 0.665 199 281
A500-01XLP2BLK105 500 35 0.736 105 0.960 471 605
A750-01XLP2BLK105 750 58 0.908 120 1.175 706 901
A1000-01XLP2BLK105 1000 58 1.060 120 1.325 941 1168
Dimensions and weights are nominal: subject to industry tolerances.
1Minimum number of wires utilized for compact-strand constructions.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 240
Copyright © 2018, American Wire Group, Inc. 20151123
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
SunGuard™ Aluminum XLPE UL Type PV Photovoltaic Wire 600V
UL Type PV/USE-2 or 2kV RHH or RHW-2 or c(UL) RWU90, 1kV, 90°C

Applications Features
Single conductor, sunlight-resistant, photo- • Rated 90°C wet and dry
voltaic wire rated 90°C wet or dry, 600 V for in- • Deformation-resistant at high temperatures
terconnection wiring of grounded and • Excellent moisture resistance, exceeds UL 44
ungrounded photovoltaic power systems as de- • Stable electrical properties over a broad tem-
scribed in Section 690.31(A) and other applica- perature range
ble parts of the National Electrical Code (NEC), • Excellent resistance to crush and compression
NFPA 70. cuts
• For use in free air, raceways or direct burial in • Resistant to most oils and chemicals
accordance with NEC. • UV/sunlight-resistant
• Meets cold bend test at -40°C
Construction
Conductor: 8 AWG thru 1000 kcmil compact alu- Compliances
minum ACM (8000 series) • UL 4703 Type PV
Insulation: Flame-retardant Cross-Linked Poly- • National Electrical Code (NEC)
ethylene (XLPE), black • ICEA S-95-658/NEMA WC70

LOW VOLTAGE CABLES


• UL 44 Type RHH or RHW-2
Print: AWG (PLANT OF MFG) SUNGUARD™ • UL 854 Type USE-2
600 V PV WIRE OR USE-2 OR 2000 V RHH OR • c(UL) RWU90 1 kV
RHW-2 (SIZE) AL ACM 90˚C WET OR DRY SUN
RES (UL) -40˚C c(UL) RWU90 1000 V DIR BUR Packaging
MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE Material cut to length and shipped on non-re-
MARK turnable wood reels.

Options
Colored phase ID stripes available on request
Multi-plexing available on request

Item # Conductor Conductor Nominal Minimum Average Nominal Cable Aluminum Net
Size Stranding Conductor O.D. Insulation Thickness Diameter Weight Weight
(AWG/ (in) (mm) (in) (mm) (in) (mm) /MFT /km /MFT /km
kcmil) (lb) (Kg) (lb) (Kg)
8 AWG - 1000 kcmil CONDUCTORS
A8-01PVX0700* 8 7/.0486 0.134 3.40 0.080 2.03 0.298 7.57 16 23 49 73
A6-01PVX0700* 6 7/.0612 0.169 4.29 0.080 2.03 0.333 8.46 25 37 64 95
A4-01PVX0700* 4 7/.0772 0.213 5.41 0.080 2.03 0.377 9.58 39 58 85 127
A2-01PVX0700* 2 7/.0974 0.268 6.81 0.080 2.03 0.432 10.97 63 93 117 174
A1-01PVX1900* 1 19/.0664 0.299 7.59 0.095 2.41 0.495 12.57 79 117 153 227
A1/0-01PVX190* 1/0 19/.0745 0.336 8.53 0.095 2.41 0.532 13.51 99 148 180 268
A2/0-01PVX1900* 2/0 19/.0837 0.376 9.55 0.095 2.41 0.572 14.53 125 186 214 318
A3/0-01PVX1900* 3/0 19/.0940 0.423 10.74 0.095 2.41 0.619 15.72 158 235 256 380
A4/0-01PVX1900* 4/0 19/.1055 0.475 12.07 0.095 2.41 0.671 17.04 199 296 307 456
A250-01PVX3700* 250 37/.0822 0.520 13.21 0.110 2.79 0.746 18.95 262 390 399 594
A300-01PVX3700* 300 37/.0900 0.570 14.48 0.110 2.79 0.796 20.22 282 420 430 640
A350-01PVX3700* 350 37/.0972 0.616 15.65 0.110 2.79 0.842 21.39 329 490 487 725
A400-01PVX3700* 400 37/.1040 0.659 16.74 0.110 2.79 0.885 22.48 376 560 544 810
A500-01PVX3700* 500 37/.1159 0.736 18.69 0.110 2.79 0.962 24.43 471 701 656 977
A600-01PVX6100* 600 61/.0992 0.813 20.65 0.125 3.18 1.069 27.15 565 841 798 1187
A750-01PVX6100* 750 61/.1109 0.908 23.06 0.125 3.18 1.164 29.57 706 1051 963 1433
A1000-01PVX6100* 1000 61/.1280 1.060 26.92 0.125 3.18 1.316 33.43 914 1360 1210 1801
Dimensions and weights are nominal; subject to industry tolerances.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 230
Copyright © 2018, American Wire Group, Inc. 20170107
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
SunGuard™ Aluminum XLPE UL Type PV Photovoltaic Wire 2kV
UL Type PV/RHH or RHW-2 or 600V USE-2 or c(UL) RWU90, 1kV 90°C
PHYSICAL & ELECTRICAL PROPERTIES

Applications • Stable electrical properties over a broad tem-


Single conductor, sunlight-resistant, photo- perature range
voltaic wire rated 90°C wet or dry, 2000 V for in- • Excellent resistance to crush and compression
terconnection wiring of grounded and cuts
ungrounded photovoltaic power systems as de- • Resistant to most oils and chemicals
scribed in Section 690.31(A) and other applica- • UV/sunlight-resistant
ble parts of the National Electrical Code (NEC), • Meets cold bend test at -40°C
NFPA 70.
Compliances
• For use in free air, raceways or direct burial in • ASTM B800 - 05(2011) Standard Specification
accordance with NEC. for 8000 Series Aluminum Alloy Wire for Elec-
Construction trical Purposes - Annealed and Intermediate
Conductor: 8 AWG thru 1000 kcmil compact alu- Tempers
minum ACM (8000 series) • ASTM B801 - 07(2012) Standard Specification
Insulation: Flame-retardant Cross-Linked Poly- for Concentric-Lay-Stranded Conductors of
ethylene (XLPE), black 8000 Series Aluminum Alloy for Subsequent

LOW VOLTAGE CABLES


Covering or Insulation
Print: AWG (PLANT OF MFG) SUNGUARD™ • ASTM B836 - 00(2011) Standard Specification
2000 V PV WIRE OR RHH OR RHW-2 OR 600 V for Compact Round Stranded Aluminum Con-
USE-2 (SIZE) AL ACM 90˚C WET OR DRY SUN ductors Using Single Input Wire Construction
RES (UL) -40˚C c(UL) RWU90 1000 V DIR BUR • UL 4703 Type PV
MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE • National Electrical Code (NEC)
MARK • ICEA S-95-658/NEMA WC70
Options • UL 44 Type RHH or RHW-2
Colored phase ID stripes available on request • UL 854 Type USE-2
• c(UL) RWU90 1kV
Multi-plexing available on request
Packaging
Features Material cut to length and shipped on non-re-
• Rated 90°C wet and dry turnable wood reels.
• Deformation-resistant at high temperatures
• Excellent moisture resistance, exceeds UL 44

Item # Conductor Conductor Nominal Minimum Average Nominal Cable Aluminum Net
Size Stranding Conductor O.D. Insulation Thickness Diameter Weight Weight
(AWG/ (in) (mm) (in) (mm) (in) (mm) /MFT /km /MFT /km
kcmil) (lb) (Kg) (lb) (Kg)
PHYSICAL PROPERTIES
A8-01PV2X0700* 8 7/.0486 0.134 3.40 0.085 2.16 0.310 7.87 16 23 52 78
A6-01PV2X0700* 6 7/.0612 0.169 4.29 0.085 2.16 0.345 8.76 25 37 67 100
A4-01PV2X0700* 4 7/.0772 0.213 5.41 0.085 2.16 0.389 9.88 39 58 90 133
A2-01PV2X0700* 2 7/.0974 0.268 6.81 0.085 2.16 0.444 11.28 63 93 122 182
A1-01PV2X1900* 1 19/.0664 0.299 7.59 0.105 2.67 0.515 13.08 79 117 162 241
A1/0-01PV2X190* 1/0 19/.0745 0.336 8.53 0.105 2.67 0.552 14.02 99 148 191 284
A2/0-01PV2X1900* 2/0 19/.0837 0.376 9.55 0.105 2.67 0.592 15.04 125 186 225 334
A3/0-01PV2X1900* 3/0 19/.0940 0.423 10.74 0.105 2.67 0.639 16.23 158 235 267 398
A4/0-01PV2X1900 4/0 19/.1055 0.475 12.07 0.105 2.67 0.691 17.55 199 296 319 475
A250-01PV2X3700 250 37/.0822 0.520 13.21 0.120 3.05 0.766 19.46 262 390 413 615
A300-01PV2X3700 300 37/.0900 0.570 14.48 0.120 3.05 0.816 20.73 282 420 445 663
A350-01PV2X3700 350 37/.0972 0.616 15.65 0.120 3.05 0.862 21.89 329 490 503 749
A400-01PV2X3700 400 37/.1040 0.659 16.74 0.120 3.05 0.905 22.99 376 560 561 835
A500-01PV2X3700 500 37/.1159 0.736 18.69 0.120 3.05 0.982 24.94 471 701 675 1004
A600-01PV2X6100* 600 61/.0992 0.813 20.65 0.135 3.43 1.089 27.66 565 841 818 1217
A750-01PV2X6100* 750 61/.1109 0.908 23.06 0.135 3.43 1.184 30.07 706 1051 985 1466
A1000-01PV2X6100* 1000 61/.1280 1.060 26.92 0.135 3.43 1.336 33.93 914 1360 1235 1838
Dimensions and weights are nominal; subject to industry tolerances.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 225
Copyright © 2018, American Wire Group, Inc. 20170107
SunGuard™ Aluminum XLPE UL Type PV Photovoltaic Wire
Type PV/RHH or RHW-2 2kV or 600V USE-2
PHYSICAL & ELECTRICAL PROPERTIES

Item # Conductor DC Resistance Positive Capacitance Three Core Three Core Three Core
Size of Conductor Sequence x10-9F/m Paralleled Paralleled Paralleled
(AWG/ ohms/km @ 20°C @90°C of Inductance Positive Sequence Zero-Sequence
kcmil) Conductor mH/km Reactance Reactance
Ohms/km H/km H/km
ELECTRICAL PROPERTIES
A8-01PV2X0700* 8 3.446 4.39 0.151 0.543 0.1705 0.053
A6-01PV2X0700* 6 2.168 2.76 0.178 0.517 0.1625 0.045
A4-01PV2X0700* 4 1.363 1.74 0.210 0.495 0.1555 0.038
A2-01PV2X0700* 2 0.857 1.093 0.251 0.475 0.1493 0.032
A1-01PV2X1900* 1 0.680 0.867 0.233 0.483 0.1518 0.034
A1/0-01PV2X190* 1/0 0.539 0.687 0.255 0.474 0.1488 0.031
A2/0-01PV2X1900* 2/0 0.428 0.545 0.279 0.465 0.1461 0.029
A3/0-01PV2X1900* 3/0 0.3389 0.432 0.307 0.457 0.1435 0.026
LOW VOLAGE CABLES

A4/0-01PV2X1900 4/0 0.2690 0.343 0.338 0.449 0.1411 0.024


A250-01PV2X3700 250 0.2277 0.291 0.328 0.451 0.1418 0.025
A300-01PV2X3700 300 0.1896 0.242 0.354 0.446 0.1400 0.023
A350-01PV2X3700 350 0.1624 0.208 0.385 0.444 0.1396 0.022
A400-01PV2X3700 400 0.1424 0.182 0.407 0.440 0.1384 0.021
A500-01PV2X3700 500 0.1139 0.146 0.447 0.434 0.1365 0.019
A600-01PV2X6100* 600 0.0948 0.122 0.441 0.435 0.1366 0.019
A750-01PV2X6100* 750 0.0758 0.0980 0.485 0.429 0.1349 0.018
A1000-01PV2X6100* 1000 0.0568 0.0743 0.555 0.422 0.1326 0.015

AA8000
Maximum Electrical Resistivity
Temperature 20℃

AWG size Ω/1000ft Ω/1000m AWG size Ω/1000ft Ω/1000m


8 1.07 3.515 250kmil 0.07076 0.2322
7 0.8495 2.787 300 0.05897 0.1935
6 0.674 2.211 350 0.05054 0.1659
5 0.5346 1.754 400 0.04423 0.145
4 0.4238 1.39 450 0.03931 0.1289
3 0.3361 1.103 500 0.03537 0.1161
2 0.2665 0.8745 550 0.03216 0.1055
1 0.2113 0.6934 600 0.02948 0.09673
1/0 0.1676 0.5498 700 0.02527 0.08291
2/0 0.1329 0.4361 750 0.02358 0.07738
3/0 0.1055 0.3459 800 0.02211 0.07254
4/0 0.836 0.2743 900 0.01966 0.06448
1000 0.01769 0.05804

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
225 Information on this sheet subject to change without notice.
20170107 Copyright © 2018, American Wire Group, Inc.
SunGuard™ Duplexed Aluminum XLPE UL
Type PV Photovoltaic Wire 2kV

Applications Features
Duplexed conductors are sunlight-resistant, • Rated 90ºC wet and dry
photovoltaic wire rated 90°C wet or dry, 2000 • Deformation-resistant at high temperatures
volts for interconnection wiring of grounded • Excellent moisture resistance, exceeds UL 44
and ungrounded photovoltaic power systems as • Stable electrical properties over a broad tem-
described in Section 690.31(A) and other appli- perature range
cable parts of the National Electrical Code • Excellent resistance to crush and compression
(NEC), NFPA 70. cuts
• For use in free air, raceways or direct burial in • Resistant to most oils and chemicals
accordance with NEC. • UV/sunlight-resistant
• Meets cold bend test at -40ºC
Construction • Use Duplex SunGard to avoid mismatch of
Conductor: 8 AWG thru 1000 kcmil compact alu- Positive and Negative sets
minum ACM (8000 series) conductors. Insula- • Reduce labor costs and equipment cost for
tion is Flame-Retardant Cross-Linked laying cable in trench by deploying one reel,
Polyethylene (XLPE), black, suitable for 2000 V. instead of two

LOW VOLTAGE CABLES


Print Legend: AWG (PLANT OF MFG) SUN-
GUARD™ 2000 V PV WIRE OR RHH OR RHW-2 Standards
OR 600 V USE-2 (SIZE) AL ACM 90°C WET OR • Rated 90°C wet and dry
DRY SUN RES (UL) -40 ºC c(UL) RWU90 1000 V • Deformation-resistant at high temperatures
DIR BUR MONTH/YEAR OF MFG SEQUENTIAL • Excellent moisture resistance, exceeds UL 44
FOOTAGE MARK • Stable electrical properties over a broad tem-
perature range
Duplexing: One phase conductor is black, the • Excellent resistance to crush and compression
other conductor is black with three white cuts
stripes. Conductors are pre-twisted together on • Resistant to most oils and chemicals
reel. • UV/sunlight-resistant
• Meets cold bend test at -40ºC
• Material cut to length and shipped on non-re-
turnable wood reels.

Item # Conductor Single Nominal Minimum Duplexed Aluminum Net


Size Conductor Conductor Average Cable Weight Weight
(AWG/kcmil) Stranding OD Insulation Diameter (lb/MFT) (lb/MFT)
(in) Thickness (in)
(in)
A8-02PV2X0700 8 7/.0486 0.134 0.085 0.62 32 104
A6-02PV2X0700 6 7/.0612 0.169 0.085 0.69 50 134
A4-02PV2X0700 4 7/.0772 0.213 0.085 0.78 78 180
A2-02PV2X0700 2 7/.0974 0.268 0.085 0.89 126 244
A1-02PV2X1900 1 19/.0664 0.299 0.105 1.03 158 324
A1/0-02PV2X190 1/0 19/.0745 0.336 0.105 1.10 198 382
A2/0-02PV2X1900 2/0 19/.0837 0.376 0.105 1.18 250 450
A3/0-02PV2X1900 3/0 19/.0940 0.423 0.105 1.28 316 534
A4/0-02PV2X1900 4/0 19/.1055 0.475 0.105 1.38 398 638
A250-02PV2X3700 250 37/.0822 0.520 0.120 1.53 524 826
A300-02PV2X3700 300 37/.0900 0.570 0.120 1.63 564 890
A350-02PV2X3700 350 37/.0972 0.616 0.120 1.72 658 1006
A400-02PV2X3700 400 37/.1040 0.659 0.120 1.81 752 1122
A500-02PV2X3700 500 37/.1159 0.736 0.120 1.96 942 1350
A600-02PV2X6100 600 61/.0992 0.813 0.135 2.18 1130 1636
A750-02PV2X6100 750 61/.1109 0.908 0.135 2.37 1412 1970
A1000-02PV2X6100 1000 61/.1280 1.060 0.135 2.67 1828 2470

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 234
Copyright © 2018, American Wire Group, Inc. 20170107
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
SunGuard™ Paralleled Aluminum XLPE UL
Type PV Photovoltaic Wire 2kV

Applications • Stable electrical properties over a broad tem-


Paralleled conductors are sunlight-resistant, perature range
photovoltaic wire rated 90°C wet or dry, 2000 • Excellent resistance to crush and compression
volts for interconnection wiring of grounded cuts
and ungrounded photovoltaic power systems as • Resistant to most oils and chemicals
described in Section 690.31(A) and other appli- • UV/sunlight-resistant
cable parts of the National Electrical Code • Meets cold bend test at 40°C
(NEC), NFPA 70. • Use Parallel SunGard to avoid mismatch of
• For use in free air, raceways or direct burial in Positive and Negative sets
accordance with NEC. • Reduce labor costs and equipment cost for
laying cable in trench by deploying one reel,
Construction instead of two
Conductor: 8 AWG thru 1000 kcmil compact alu-
minum ACM (8000 series) conductors. Insula- Standards
tion is Flame-Retardant Cross-Linked • Rated 90°C wet and dry
Polyethylene (XLPE), black, suitable for 2000 V. • Deformation-resistant at high temperatures

LOW VOLTAGE CABLES


Print Legend: AWG (PLANT OF MFG) SUN- • Excellent moisture resistance, exceeds UL 44
GUARD™ 2000 V PV WIRE OR RHH OR RHW-2 • Stable electrical properties over a broad tem-
OR 600 V USE-2 (SIZE) AL ACM 90°C WET OR perature range
DRY SUN RES (UL) 40°C c(UL) VW-1 RWU90 • Excellent resistance to crush and compression
1000 V DIR BUR MONTH/YEAR OF MFG SE- cuts
QUENTIAL FOOTAGE MARK • Resistant to most oils and chemicals
• UV/sunlight-resistant
Paralleling: One phase conductor is black with • Meets cold bend test at 40°C
red stripes, the other conductor is white with • VW-1 Rating upon available upon request
red stripes. Conductors are preinstalled to-
gether on reel. Note
Material cut to length and shipped on non-re-
Features turnable wood or steel reels
• Rated 90°C wet and dry
• Deformation-resistant at high temperatures Option
• Excellent moisture resistance, exceeds UL 44 UL 1581 VW-1 compliance available on request

Item # Conductor Conductor Nominal Minimum Duplexed Aluminum Net Cable


Size Stranding Conductor Average Cable Weight Weight
(AWG/kcmil) O.D. (in) Insulation Diameter (lbs/MFT) (lbs/MFT)
Thickness (in) (in)
A802PV2X0700* 8 7/.0486 0.134 0.085 .62 32 104
A602PV2X0700* 6 7/.0612 0.169 0.085 .69 50 134
A402PV2X0700* 4 7/.0772 0.213 0.085 .78 78 180
A202PV2X0700* 2 7/.0974 0.268 0.085 .89 126 244
A102PV2X1900* 1 19/.0664 0.299 0.105 1.03 158 324
A1/002PV2X190* 1/0 19/.0745 0.336 0.105 1.10 198 382
A2/002PV2X1900* 2/0 19/.0837 0.376 0.105 1.08 250 450
A3/002PV2X1900* 3/0 19/.0940 0.423 0.105 1.28 316 534
A4/002PV2X1900* 4/0 19/.1055 0.475 0.105 1.38 398 638
A25002PV2X3700* 250 37/.0822 0.520 0.120 1.53 524 826
A30002PV2X3700* 300 37/.0900 0.570 0.120 1.63 564 890
A35002PV2X3700* 350 37/.0972 0.616 0.120 1.72 658 1006
A40002PV2X3700* 400 37/.1040 0.659 0.120 1.81 752 1122
A50002PV2X3700* 500 37/.1159 0.736 0.120 1.96 942 1350
A60002PV2X6100* 600 61/.0992 0.813 0.135 2.18 1130 1636
A75002PV2X6100* 750 61/.1109 0.908 0.135 2.37 1412 1970
A100002PV2X6100* 1000 61/.1280 1.060 0.135 2.67 1828 2470

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 243
Copyright © 2018, American Wire Group, Inc. 20180201
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
20X Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Copper PVC UL THW-2
75°C 600V

Application
Single conductor general purpose wiring for lighting and power. The product is insulated with
polyvinylchloride (PVC), and dual rated as UL Types TW and THW. It is intended for use in accor-
dance with the NEC in residential, commercial and industrial applications not exceeding 600V
and/or 75°C in wet or dry locations.

Construction
• Single conductor copper insulated with polyvinylchloride (PVC), solid or stranded, tinned or bare
soft annealed copper per ASTM B-3, B-8 and complying with the physical and electrical require-
ments of UL standards 83 and 1851.
• Identified by surface marking indicating manufacturers identification, conductor size, voltage rat-
ing, and UL Type TW and THW designations.
Standards
• Underwriters Lab standard 83 for thermoplastic insulated wires.
• Underwriters Lab standard 1581 for wires, cables, and cords.

LOW VOLTAGE CABLES


• ICEA S-95-658/NEMA WC70
• Federal Specification JC-30B

Item # Size AWG Number of Insulation Approximate Amapcity Shipping


or MCM Strands Thickness O.D. 3/C in Weight
(mil) (in) Raceway /MFT
(lb)
THW-C14S 14 Solid 45 0.16 15 22
THW-C12S 12 Solid 45 0.18 20 31
THW-C10S 10 Solid 45 0.20 30 45
THW-C14 14 7 45 0.17 15 24
THW-C12 12 7 45 0.19 20 33
THW-C10 10 7 45 0.21 30 48
THW-C8 8 7 60 0.20 50 77
THW-C6 6 7 60 0.31 65 112
THW-C4 4 7 60 0.36 85 167
THW-C3 3 7 60 0.39 100 202
THW-C2 2 7 60 0.42 115 252
THW-C1 1 19 80 0.49 130 324
THW-C1/0 1/0 19 80 0.53 150 397
THW-C2/0 2/0 19 80 0.58 175 491
THW-C3/0 3/0 19 80 0.63 200 608
THW-C4/0 4/0 19 80 0.69 230 753
THW-C250 250 37 95 0.77 255 896
THW-C300 300 37 95 0.82 285 1060
THW-C350 350 37 95 0.87 310 1227
THW-C400 400 37 95 0.95 335 1391
THW-C500 500 37 95 1.01 380 1715

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 219
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Copper PVC UL TFFN/TFN
90°C 600V

Applications
For internal wiring of fixtures, fixture raceways, fire alarm circuits in raceways.

Construction
• Conductor is fully Annealed bare copper per ASTM B-3 and B-174.
• Insulation is color coded premium grade flame retardant PVC (polyvinyl chloride).
• Jacket is tough polyamide nylon.
• VW-1 Flame Test rated.
• Gasoline and Oil Resistant II
• Resistant to abrasion, acids, alkalines, ozone and water.
Standards
• ASTM B-3 and B-174.
• UL Standard 62 for fixture wire.
• UL Standard 1063 for machine tool wire
• NY State DOS 16120-880926-2008

LOW VOLTAGE CABLES


• OSHA acceptable
• NFPA 70 (NECR)
• NFPA 79 AWM 600V 105°C (75°C in oil).

Item # Conductor Number of Approx. Insulation Jacket Shipping


Size Strands O.D. Thickness Thickness Weight
AWG (in) (mil) (mil) /MFT
(lb)
TFFN-C18 18 16 0.088 15 4 8
TFFN-C16 16 26 0.101 15 4 12
TFN-C18S 18 Solid 0.088 15 4 8
TFN-C16S 16 Solid 0.101 15 4 12

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 226
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Copper PVC/Nylon UL THHN/THWN-2
90°C Dry or 75°C Wet 600V

Application
General purpose building wire for services, feeders and branch circuits. Suitable for use in conduit
and raceways; 1/0 and larger for cable tray use.

Construction
• Conductor is bare annealed copper per ASTM B-3.
• Stranded conductors per ASTM B-8.
• Insulation is color coded premium grade flame retardant PVC (polyvinyl chloride).
• Jacket is tough polyamide nylon.
• VW-1 AWG rated through 4/0 AWG.
• 1/0 AWG and larger rated for CT use.
• 1/0 AWG and larger rated Sunlight Resistant.
• Gasoline and Oil Resistant II.
• Resistant to abrasion, acids, alkalines, ozone, and water.
Standards

LOW VOLTAGE CABLES


• ASTM B-3 and B-8
• UL Standard 83 — THHN/THWN-2
• UL Standard 1581 for machine tool wire
• ICEA S-95-658/NEMA WC70
• Federal Specification JC-30B
• OSHA acceptable
• NFPA 70 (NECR)
• NFPA 79 AWM 600V 105°C (75°C in oil).

Item # Size AWG Number of Insulation Nylon Approximate Amapcity Ampacity Shipping
or MCM Strands Thickness Jacket O.D. 75°C 90°C Weight
(mil) Thickness (in) Wet Dry /MFT
(mil) (lb)
THHN-C14S 14 Solid 15 4 0.102 20 25 17
THHN-C12S 12 Solid 15 4 0.118 25 30 25
THHN-C10S 10 Solid 20 4 0.150 30 40 39
THHN-C14 14 19 15 4 0.110 20 25 18
THHN-C12 12 19 15 4 0.128 25 30 27
THHN-C10 10 19 20 4 0.161 35 35 40
THHN-C8 8 19 30 5 0.212 50 55 69
THHN-C6 6 19 30 5 0.250 65 75 109
THHN-C4 4 19 40 6 0.318 85 95 166
THHN-C3 3 19 40 6 0.345 100 105 202
THHN-C2 2 19 40 6 0.375 115 130 254
THHN-C1 1 19 50 7 0.430 130 150 316
THHN-C1/0 1/0 19 50 7 0.470 150 170 398
THHN-C2/0 2/0 19 50 7 0.515 175 195 488
THHN-C3/0 3/0 19 50 7 0.565 200 225 603
THHN-C4/0 4/0 19 50 7 0.620 230 260 731
THHN-C250 250 37 50 7 0.730 255 290 903
THHN-C300 300 37 60 8 0.780 285 320 1058
THHN-C350 350 37 60 8 0.830 310 350 1211
THHN-C400 400 37 60 8 0.880 335 380 1332
THHN-C500 500 37 60 8 0.970 380 430 1735
THHN-C600 600 61 70 9 1.060 420 475 1990
THHN-C750 750 61 70 9 1.170 475 535 2428
THHN-C1000 1000 61 70 9 1.300 545 615 3263

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 218
Copyright © 2018, American Wire Group, Inc. 20140925
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
UF-B
Copper Underground Feeder
600V 75°C

Applications
For direct burial, for use in dwellings not exceeding 3 floors above grade, as underground feeder to
outdoor lighting or apparatus, or as general branch circuit wiring. Recognized for use as exposed or
concealed wiring in damp, moist, wet, dry, and corrosive locations. For use as new wiring or as re-
placement wiring.

Construction
• Conductor is bare annealed copper per ASTM B-3 or stranded conductors, per ASTM B-8.
• Insulation is color coded PVC (polyvinyl chloride) with a nylon jacket.
• Type THHN inners, rated 90°C.
• Ampacity is limited to that for 60°C conductors per NECR Articles 336 and 339.
• Jacket is gray PVC (polyvinyl chloride).
• Color code — 2 conductor: black, white; 3 conductor: black, white, red.
Standards
• Listed under UL Standard 493.

LOW VOLTAGE CABLES


• Federal Specification JC-30B.
• ASTM B-3 and B-8

Item # Constr./ Number of Ground Approximate Shipping


Size AWG Strands Wire O.D. Weight
Size (in) /MFT
(lb)
UFB-1 14/2 Solid (None) .20 x .39 60
UFB-2 12/2 Solid (None) .21 x .42 79
UFB-3 10/2 Solid (None) .23 x .46 107
UFB-4 14/3 Solid (None) .20 x .57 97
UFB-5 12/3 Solid (None) .21 x .62 130
UFB-6 10/3 Solid (None) .23 x .68 173
UFB-7 8/3 7 (None) .34 x .96 284
UFB-8 6/3 7 (None) .40 x 1.20 467
UFB-9 14/2 Solid 14 .21 x .40 79
UFB-10 12/2 Solid 12 .22 x .43 107
UFB-11 10/2 Solid 10 .24 x .47 148
UFB-12 8/2 7 10 .32 x .62 246
UFB-13 6/2 7 10 .41 x .81 358
UFB-14 14/3 Solid 14 .20 x .57 111
UFB-15 12/3 Solid 12 .21 x .62 151
UFB-16 10/3 Solid 10 .23 x .68 207
UFB-17 8/3 7 10 .34 x .96 317
UFB-18 6/3 7 10 .40 x 1.20 501

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 220
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Copper XLP UL XHHW-2
600V 90°C Wet or Dry

Applications
Single conductor crosslinked polyethylene (XLP or XLPE) Type XHHW-2, intended for use at 600
volts or less. It is approved for general purpose lighting and power applications at a maximum con-
tinuous operating temperature of 90°C in wet or dry locations. VW-1 available where required.

Construction
Single copper conductors, solid or stranded annealed or hard uncoated copper per UL83 and ASTM
requirements. Insulates with XLP as specified and applied tightly to the conductor in a concentric
manner. The mimimum at any point shall not be less than 90% of the specified average thickness in
compliance with UL 44. Identified by surface marking indicating the manufacturer, conductor size,
voltage rating, UL symbol, and type designation. Continuously spark tested at 7500 Volts DC and
pass the 4 hour cold bend test of -25°C. Other electrical and mechanical tests shall be in accordance
with UL 44 and UL 1581.

Standards
• Underwriter’s Laboratories UL 44

LOW VOLTAGE CABLES


• Canadian Standard C22.2 No. 38
• Insulated Cable Engineers Association ICEA S-95-658
• Institute of Electrical and Electronics Engineers IEEE 1202
• Federal Specification A-A-59544
• NEMA Publication No. WC-70
• Gas and Oil Resistant II (UL)

Item # Size Number of Insulation Approximate Copper Shipping Ampacity


AWG or Strands Thickness O.D. Weight Weight 90°C
MCM (mil) (in) /MFT /MFT Dry
(lb) (lb)
XHHW-C14 14 7/19 30 0.140 12.7 18 15
XHHW-C12 12 7/19 30 0.160 20.2 27 20
XHHW-C10 10 7/19 30 0.180 32.1 41 30
XHHW-C8 8 7 45 0.240 51.0 67 55
XHHW-C6 6 7 45 0.280 81.1 100 75
XHHW-C4 4 7 45 0.330 128.9 153 95
XHHW-C3 3 7 45 0.349 162.5 190 110
XHHW-C2 2 7 45 0.390 204.9 236 130
XHHW-C1 1 19 55 0.450 258.4 292 150
XHHW-C1/0 1/0 19 55 0.490 325.8 363 170
XHHW-C2/0 2/0 19 55 0.535 410.9 452 195
XHHW-C3/0 3/0 19 55 0.590 518.1 562 225
XHHW-C4/0 4/0 19 55 0.645 653.3 702 260
XHHW-C250 250 37 65 0.715 771.9 831 290
XHHW-C300 300 37 65 0.770 926.3 1000 320
XHHW-C350 350 37 65 0.820 1081.0 1160 350
XHHW-C400 400 37 65 0.870 1235.0 1322 N/A
XHHW-C500 500 37 65 0.955 1544.0 1643 430
XHHW-C600 600 61 80 1.040 1853.0 1982 475
XHHW-C750 750 61 80 1.150 2316.0 2461 535
XHHW-C1000 1000 61 80 1.300 3008.0 3257 615

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 222
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Copper XLP Type SIS VW-1
90°C 600V

Applications
Single conductor cross-linked polyethylene (XLP or XLPE) Type SIS-VW-1 for use at 600V or less.
Approved per NEC Article 384 for instrument and control wiring where wiring is required to pass
the UL vertical flame test. Rated for a maximum continuous operating temperature of 90°C in wet or
dry locations.

Construction
• Stranded conductor, annealed, coated copper per UL83 and ASTM requirements.
• Insulated with XLP as specified and applied tightly to the conductor in a concentric manner.
• Conductors are “Oil and Gas Resistant II.”
• The standard color is gray; other colors available.
• All black insulation is rated “Sunlight Resistant.”
• The minimum at any point shall not be less than 90% of the specified average thickness in compli-
ance with UL 44.
• Identified by surface marking indicating manufacturers identification, conductor size, voltage rat-
ing, and UL symbol, VW-1, and type designation.

LOW VOLTAGE CABLES


• Continuously spark tested at 7500V DC and pass the 4 hour cold bend test at -25°C. Other electri-
cal and mechanical tests shall be in accordance with UL 44 and UL 1581.
Standards
• Tin-coated, soft annealed copper per ASTM B-33, Class B stranding ASTM B-8
• ICEA S-95-658/NEMA WC-70
• UL 44 for Thermoset Insulated Wires & Cables
• Fed Spec J-C-30B

Item # Size Number of Optional Insulation Nominal Shipping


AWG Strands Stranding Thickness Overall Weight
(mil) Diameter /MFT
(in) (lb)
SIS-1-18 18 16 7, 19 30 .09 / .10 11
SIS-2-16 16 26 7, 19 30 .11 / .12 15
SIS-3-14 14 41 7, 19 30 0.13 / 0.14 21
SIS-4-12 12 65 7, 19 30 0.15 / 0.16 27
SIS-5-10 10 105 7, 19 30 0.17 / 0.18 40
SIS-6-8 8 133 7, 19 45 0.24 / 0.25 75
SIS-7-6 6 133 7, 19 45 0.28 / 0.30 115
SIS-8-4 4 133 7, 19 45 0.32 / 0.34 175
SIS-9-2 2 133 7, 19 45 0.38 / 0.40 250
SIS-10-1 1 133 19, 37 55 0.44 / 0.48 330
SIS-11-1/0 1/0 133 19, 37 55 0.48 / 0.52 400

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 221
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Copper XLP UL RHH/RHW-2 or USE-2
90°C 600V

Applications
Single conductor cross-linked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600V or
less. It is approved per the NEC for general purpose lighting and power applications at a maximum
continuous operating temperature of 90°C in wet and dry locations. Suitable for direct burial.

Construction
The single copper conductors shall be solid or stranded annealed or hard uncoated copper per
UL83 and ASTM requirements. Insulated with XLP as specified and applied tightly to the conductor
in a concentric manner. All black insulation is rated “Sunlight Resistant.” The minimum at any point
shall not be less than 90% of the specified average thickness in compliance with UL 44. The wire
shall be identified by surface marking indicating the manufacturer, conductor size, voltage rating,
UL symbol, and type designation. The wire shall be continuously spark tested at 7500V DC. Other
electrical and mechanical tests shall be in accordance with UL44, UL 854 and UL 1581.

Standards
• ASTM B-1, B-3 and B-8 for copper conductors

LOW VOLTAGE CABLES


• ICEA S-95-658/NEMA WC70
• UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44
for Thermoset Insulated Wires & Cables
• Fed Spec J-C-30B

Item # Size Number of Insulation Approximate Copper Shipping Ampacity


AWG or Strands Thickness O.D. Weight Weight 90°C
MCM (mil) (in) /MFT /MFT Dry
(lb) (lb)
USE2-C14 14 7 45 0.16 12.7 22 15
USE2-C12 12 7 45 0.17 20.2 31 20
USE2-C10 10 7 45 0.20 32.1 45 30
USE2-C8 8 7 60 0.27 51.0 74 55
USE2-C6 6 7 60 0.31 81.1 108 75
USE2-C4 4 7 60 0.37 128.9 161 95
USE2-C3 3 7 60 0.39 162.5 198 110
USE2-C2 2 7 60 0.43 204.9 244 130
USE2-C1 1 19 80 0.51 258.4 319 150
USE2-C1/0 1/0 19 80 0.56 325.8 392 170
USE2-C2/0 2/0 19 80 0.60 410.9 484 195
USE2-C3/0 3/0 19 80 0.66 518.1 599 225
USE2-C4/0 4/0 19 80 0.72 653.3 743 260
USE2-C250 250 37 95 0.80 771.9 889 290
USE2-C300 300 37 95 0.86 926.3 1053 320
USE2-C350 350 37 95 0.91 1081.0 1217 350
USE2-C400 400 37 95 0.94 1235.0 1379 380
USE2-C500 500 37 95 1.05 1544.0 1703 430
USE2-C600 600 61 110 1.16 1853.0 2056 475
USE2-C750 750 61 110 1.27 2316.0 2540 535
USE2-C1000 1000 61 110 1.44 3008.0 3343 615

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 223
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
SunGuard™ Copper XLPE UL Type PV Photovoltaic Wire
UL Type PV/RHH or RHW-2 600V or 600V USE-2

Applications Industry Listings & Standards


For use in grounded and ungrounded Photo- Industry Compliances
voltaic power systems • UL 4703 Type PV
• National Electrical Code (NEC)
Construction • ICEA S-95-658/NEMA WC70
• Stranded bare and tinned copper conductors • UL 44 Type RHH or RHW-2
per ASTM B-3, B-8. • UL 854 Type USE-2 for 600 V
• Chemically Cross-linked Polyethylene insula- • c(UL) RWU90 1 kV (-40C)
tion.
• Available Colors: Black, Green, White, Red. Other Compliances
• Print on one side with a contrasting ink. An ex- • EPA 40 CFR, Part 261 for leachable lead con-
truded stripe and other colors are available tent per TCLP
upon request. • OSHA Acceptable
• RoHS Compliant
Option

LOW VOLTAGE CABLES


UL 1581 VW-1 compliance available on request
19 strand conductors available on request

Packaging
Material cut to length and shipped on non-re-
turnable wood reels

Item # AWG Stranding Nominal Nominal Minimum Minimum Nominal Nominal Copper Copper Net Net
Conductor Conductor Average Average Cable Cable Weight Weight Weight Weight
O.D. O.D. Insulation Insulation Diameter Diameter (lb/MFT) (kg/km) (lb/MFT) (kg/km)
(in) (mm) (in) (mm) (in) (mm)
PV-600-18 18 7 0.045 1.14 0.060 1.52 0.169 4.29 5 7 14 21
PV-600-16 16 7 0.056 1.42 0.060 1.52 0.180 4.57 8 12 18 27
PV-600-14 14 7 0.070 1.78 0.060 1.52 0.194 4.93 13 19 27 40
PV-600-12 12 7 0.088 2.23 0.060 1.52 0.214 5.43 20 30 36 54
PV-600-10 10 7 0.112 2.84 0.060 1.52 0.238 6.04 32 48 51 76
PV-600-08 8 7 0.143 3.63 0.080 2.03 0.307 7.80 50 74 85 126
PV-600-06 6 7 0.184 4.67 0.080 2.03 0.348 8.84 81 121 123 183
PV-600-04 4 7 0.234 5.94 0.080 2.03 0.398 10.11 129 192 180 268
PV-600-02 2 7 0.296 7.52 0.080 2.03 0.460 11.68 205 305 267 397
PV-600-01 1 19 0.323 8.20 0.095 2.41 0.515 13.08 258 384 333 495
PV-600-1/0 1/0 19 0.370 9.40 0.095 2.41 0.563 14.30 326 485 410 610
PV-600-2/0 2/0 19 0.410 10.41 0.095 2.41 0.608 15.44 411 611 502 747
PV-600-3/0 3/0 19 0.460 11.68 0.095 2.41 0.658 16.71 518 771 620 922
PV-600-4/0 4/0 19 0.520 13.21 0.095 2.41 0.714 18.13 653 972 767 1141
PV-600-250 250 37 0.558 14.17 0.110 2.79 0.784 19.91 772 1149 923 1374
PV-600-300 300 37 0.611 15.52 0.110 2.79 0.837 21.26 926 1378 1090 1622
PV-600-350 350 37 0.661 16.79 0.110 2.79 0.887 22.53 1063 1582 1240 1845
PV-600-400 400 37 0.706 17.93 0.110 2.79 0.932 23.67 1235 1838 1423 2117
PV-600-500 500 37 0.789 20.04 0.110 2.79 1.015 25.78 1509 2246 1718 2557
PV-600-600 600 61 0.866 22.00 0.125 3.18 1.122 28.50 1883 2802 2136 3179
PV-600-750 750 61 0.968 24.59 0.125 3.18 1.224 31.09 2316 3447 2597 3865
PV-600-1000 1000 61 1.117 28.37 0.125 3.18 1.373 34.87 3088 4595 3411 5076

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 203
Copyright © 2018, American Wire Group, Inc. 20180201
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Copper EPR/CPE RHH/RHW-2 or USE-2
90°C 600V

Applications
Recommended for use in all low voltage circuits where continuity of service is the prime considera-
tion. These cables may be installed in wet or dry locations, indoors or outdoors, in raceways, under-
ground ducts, directly buried in the earth, or lashed to a messenger for aerial installation. These
cables may also be installed in cable tray (size 1/0 AWG and larger per NEC 392.2).

Specifications
Conductor: Uncoated copper solid per ASTM-B-3, compress stranded per ASTM B-8, or compact per
ASTM B-496.
Insulation: Meets or exceeds all requirements of ICEA S-95-658/NEMA WC-70 and UL Standards 44
and 854.
Jacket: CSPE. Listed by Underwriters Laboratories, Inc. as Type RHH or RHW-2 or USE-2, VW-1. Sizes
1/0 AWG and larger are also marked “sunlight resistant, for use in cable tray.”
Listed by CSA as RW-90, -25C, FT1 (1/0 and larger FT4), outdoor.

LOW VOLTAGE CABLES


Product Features
• Sizes 1/0 AWG and larger pass the Vertical Tray Flame Test requirements of UL 1581 for use in
cable tray.
• Passes the IEEE 383-1974 Vertical Tray Flame Test.
• Passes the IEEE 1202-1991 Vertical Tray Flame Test. (sizes 1/0 AWG & larger).
• Extreme heat resistance; 90°C continuous rating, wet or dry 110°C hot spot rating 130°C emer-
gency overload rating 250°C short circuit rating
Notes
These ampacities are based on single conductor in free air, 40°C ambient air temperature, 90°C con-
ductor operating temperature.

Options
PVC or LSOH jacket

Item # Conductor Conductor Conductor Nominal Nominal Jacket Thickness Nominal Approx. Ampacity
Size Stranding Diameter Insulation Min. Min. Approx. Approx. Max. Max. O.D. Weight 40°C
AWG or (in) (in) (in) (mm) (in) (mm) (in) (mm) (in) /MFT Ambient
MCM (lb) Temp.
USE2-14 14 AWG 7 0.072 0.030 0.161 4.10 0.165 4.20 0.177 4.50 0.236 24 25
USE2-12 12 AWG 7 0.091 0.030 0.185 4.70 0.189 4.80 0.205 5.20 0.256 34 32
USE2-10 10AWG 7 0.116 0.030 0.205 5.20 0.213 5.40 0.228 5.80 0.290 49 47
USE2-8 8 AWG 7 0.146 0.045 0.268 6.80 0.276 7.00 0.299 7.60 0.333 79 83
USE2-6 6 AWG 7 0.183 0.045 0.335 8.50 0.346 8.80 0.374 9.50 0.403 124 109
USE2-4 4 AWG 7 0.231 0.045 0.382 9.70 0.394 10.0 0.425 10.80 0.461 179 145
USE2-2 2 AWG 7 0.292 0.045 0.441 11.20 0.453 11.50 0.488 12.40 0.510 260 192
USE2-1/0 1/0 AWG 19 0.373 0.055 0.559 14.20 0.575 14.60 0.622 15.80 0.700 420 258
USE2-2/0 2/0 AWG 19 0.419 0.055 0.602 15.30 0.619 15.73 0.669 17.00 0.740 513 298
USE2-4/0 4/0 AWG 19 0.528 0.055 0.717 18.20 0.736 18.70 0.795 20.20 0.870 774 400
USE2-250 250 MCM 37 0.575 0.065 0.827 21.00 0.850 21.60 0.917 23.30 0.990 956 445
USE2-350 350 MCM 37 0.681 0.065 0.929 23.60 0.957 24.30 1.031 26.20 1.055 1290 552
USE2-500 500 MCM 37 0.813 0.065 1.055 26.80 1.088 27.64 1.177 29.90 1.125 1798 695
USE2-750 750 MCM 61 0.980 0.080 1.264 32.10 1.303 33.10 1.406 35.70 1.205 2686 898
USE2-1000 1000MCM 61 1.152 0.080 1.413 35.90 1.457 37.0 1.575 40.00 1.305 3463 1076

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 224
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Copper XLP UL RHH/RHW-2 or USE-2
90°C 2kV

Application Standards
Type RHH, RHW-2 is suitable for wiring in race- • ASTM B3, B8 and B787
ways, conduit, etc. Applications include general • UL 44 ICEA S-95-658/NEMA WC-70
purpose wiring for power distribution, services, • For CT use 1/0 AWG and larger
feeders, and branch circuit wiring in residential, • Gasoline and Oil Resistant II
industrial, and commercial buildings. • -40°C rated to 90°C in wet and dry applications
• For use in free air, raceways or direct burial in • C(UL) US RWU90 1kV:CSA/UL Listed
accordance with NEC. • C(UL) RPVU90 1kV
• Sunlight Resistant
Construction • RoHS Compliant
Conductor: Single copper conductor, stranded
Insulation: Heat resistant cross-linked polyethyl-
ene. Temperature rating is 90°C in wet and dry
applications
Packaging: All produced or cut-to-order material

LOW VOLTAGE CABLES


will be shipped on non-returnable wooden reels
unless specifically requested.

Item # Stranding Size Insulation Nominal Approximate Ampacity*


AWG Thickness Overall Net Weight 90°C
or (mil) Diameter (lb/MFT) Wet/Dry
KCMIL (in)
14-01XLP2000 7 14 60 0.193 27 35†
12-01XLP2000 7 12 60 0.212 37 40†
10-01XLP2000 7 10 60 0.236 51 55†
8-01XLP2000 7 8 80 0.306 83 80
6-01XLP2000 7 6 80 0.344 120 105
4-01XLP2000 7 4 80 0.392 175 140
3-01XLP2000 7 3 80 0.420 212 165
2-01XLP2000 7 2 80 0.452 259 190
1-01XLP2000 19 1 95 0.511 330 220
1/0-01XLP2000 19 1/0 95 0.550 404 260
2/0-01XLP2000 19 2/0 95 0.594 497 300
3/0-01XLP2000 19 3/0 95 0.644 613 350
4/0-01XLP2000 19 4/0 95 0.700 758 405
250-01XLP2000 37 250 110 0.795 909 455
300-01XLP2000 37 300 110 0.849 1,074 500
350-01XLP2000 37 350 110 0.901 1,239 570
400-01XLP2000 37 400 110 0.948 1,402 615
500-01XLP2000 37 500 110 1.033 1,728 700
600-01XLP2000 61 600 125 1.143 2,084 780
750-01XLP2000 61 750 125 1.248 2,571 885
*Based on ambient temperature of 30°C per NEC-Table 310-17
†The overcurrent protection for items marked with an obelisk (†) shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG, and 30 amps for #10 AWG per
NEC 310-17 footnote.
Data shown is approximate and subject to standard industry tolerances.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 233
Copyright © 2018, American Wire Group, Inc. 20151123
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
DLO Copper EPR/CPE UL
RHH/RHW-2 2kV

Applications
This cable is for wiring down tower applications and may be used on electrically driven, earth mov-
ing equipment, as power supply to A.C. welding equipment, as water heater leads, and in motor
and power lead applications. May be installed in wet or dry areas, conduit, ducts, trays or troughs.

Construction
• Conductor is extra flexible tinned, stranded copper with a separator layer.
• EPR insulation.
• Jacket is CPE (Hypalon jacket available upon request).
Standards
• Meets flame test requirements of MSHA and passes ICEA cold bend test at -40°C.
• Meets AAR specifications.
• UL listed as RHH-RHW-2.
• Rated for CT use, 1/0 and larger.

LOW VOLTAGE CABLES


Notes
• Ampacity based on single conductor in free air, 90°C conductor temperature, 40°C ambient per
ICEAS-75-381.
• Sequential footage marks.
• Shipping tolerance +/- 10%

Item # Area Size Number of Insulation Jacket Overall Net Weight Ampacity
Circular AWG Strands in Thickness Thickness Diameter /MFT 1/C Free Air
(mil) Conductor (in) (mil) (in) (lb) 90°C
DL-600/2-1 3831 14 19 .045 30 .24 34 32
DL-600/2-2 6088 12 19 .045 30 .25 45 36
DL-600/2-3 10910 10 27 .045 30 .29 68 55
DL-600/2-4 14950 8 37 .060 30 .33 82 83
DL-600/2-5 24640 6 61 .060 30 .40 125 109
DL-600/2-6 36760 5 91 .060 30 .43 175 127
DL-600/2-7 42420 4 105 .060 30 .45 195 145
DL-600/2-8 60600 2 150 .060 30 .50 265 192
DL-600/2-9 90900 1 225 .080 45 .64 425 223
DL-600/2-10 111100 1/0 275 .080 45 .69 500 258
DL-600/2-11 131300 2/0 325 .080 45 .73 570 298
DL-600/2-12 181800 3/0 450 .080 45 .80 780 345
DL-600/2-13 222200 4/0 550 .080 45 .86 890 400
DL-600/2-14 262600 262.6 650 .090 65 .97 1100 458
DL-600/2-15 313100 313.1 775 .090 65 1.01 1280 514
DL-600/2-16 373700 373.7 925 .090 65 1.11 1500 574
DL-600/2-17 444400 444.4 1100 .090 65 1.18 1760 642
DL-600/2-18 535300 535.3 1325 .110 65 1.29 2110 725
DL-600/2-19 646400 646.4 1591 .110 65 1.38 2410 815
DL-600/2-20 777700 777.7 1924 .110 65 1.47 2930 910
DL-600/2-21 929200 929.2 2299 .110 65 1.58 3450 1025
DL-600/2-22 1111000 1111.0 2745 .110 65 1.74 4130 1143

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 709
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
SunGuard™ Copper XLPE UL Type PV Photovoltaic Wire
Type PV/RHH 2kV or 600kV USE-2

Applications Industry Listings & Standards


Appropriate for use in solar power applications Industry Compliances
that require 1000 or 2000 volt rating. For use in • UL 4703 Type PV
grounded and ungrounded Photovoltaic power • National Electrical Code (NEC)
systems. • ICEA S-95-658/NEMA WC70
• For use in free air, raceways or direct burial in • UL 44 Type RHH or RHW-2
accordance with NEC. • UL 854 Type USE-2 for 600 V
• c(UL) RWU90 1 kV (-40C)
Construction
• Stranded bare and tinned copper conductors Other Compliances
per ASTM B-3, B-8. • EPA 40 CFR, Part 261 for leachable lead con-
• Chemically Cross-linked Polyethylene insula- tent per TCLP
tion. • OSHA Acceptable
• Available Colors: Black, Green, White, Red. • RoHS Compliant
• Print on one side with a contrasting ink. An ex-
truded stripe and other colors are available Option

LOW VOLTAGE CABLES


upon request. UL 1581 VW-1 compliance available on request
19 strand conductors available on request

Packaging
Material cut to length and shipped on non-re-
turnable wood reels

Item # AWG Stranding Nominal Nominal Minimum Minimum Nominal Nominal Copper Copper Net Net
Conductor Conductor Average Average Cable Cable Weight Weight Weight Weight
O.D. O.D. Insulation Insulation Diameter Diameter (lb/MFT) (kg/km) (lb/MFT) (kg/km)
(in) (mm) (in) (mm) (in) (mm)
PV-2000-18 18 7 0.045 1.14 0.075 1.90 0.199 5.05 5 7 16 24
PV-2000-16 16 7 0.056 1.42 0.075 1.90 0.210 5.33 8 12 21 31
PV-2000-14 14 7 0.070 1.78 0.075 1.90 0.224 5.69 13 19 32 48
PV-2000-12 12 7 0.088 2.23 0.075 1.90 0.244 6.20 20 30 42 62
PV-2000-10 10 7 0.112 2.84 0.075 1.90 0.268 6.81 32 48 57 85
PV-2000-08 8 7 0.143 3.63 0.085 2.16 0.326 8.28 50 74 87 129
PV-2000-06 6 7 0.184 4.67 0.085 2.16 0.363 9.22 81 121 123 183
PV-2000-04 4 7 0.234 5.94 0.085 2.16 0.406 10.31 129 192 181 269
PV-2000-02 2 7 0.296 7.52 0.085 2.16 0.474 12.04 205 305 266 396
PV-2000-01 1 19 0.323 8.20 0.105 2.67 0.538 13.66 258 384 350 521
PV-2000-1/0 1/0 19 0.370 9.40 0.105 2.67 0.586 14.88 326 485 429 638
PV-2000-2/0 2/0 19 0.410 10.41 0.105 2.67 0.631 16.03 411 611 527 784
PV-2000-3/0 3/0 19 0.460 11.68 0.105 2.67 0.674 17.12 518 771 647 963
PV-2000-4/0 4/0 19 0.520 13.21 0.105 2.67 0.737 18.72 653 972 796 1184
PV-2000-250 250 37 0.558 14.17 0.120 3.05 0.804 20.42 772 1149 938 1396
PV-2000-300 300 37 0.611 15.52 0.120 3.05 0.857 21.77 926 1378 1106 1646
PV-2000-350 350 37 0.661 16.79 0.120 3.05 0.907 23.04 1063 1582 1257 187
PV-2000-400 400 37 0.706 17.93 0.120 3.05 0.952 24.18 1235 1838 1441 2144
PV-2000-500 500 37 0.789 20.04 0.120 3.05 1.035 26.29 1509 2246 1737 2585
PV-2000-600 600 61 0.866 22.00 0.135 3.43 1.142 29.01 1883 2802 2157 3211
PV-2000-750 750 61 0.968 24.59 0.135 3.43 1.244 31.60 2316 3447 2620 3900
PV-2000-1000 1000 61 1.117 28.37 0.135 3.43 1.393 35.38 3088 4595 3437 5115

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 231
Copyright © 2018, American Wire Group, Inc. 20180201
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
LSZH XLPO/LSZH XLPO
Low-Voltage Power, Unshielded 600 V
UL Type RHH/RHW-2/USE-2

Applications • Resistant to most oils and chemicals


For use in closed environments or populated • UV/sunlight-resistant
spaces such as auditoriums, arenas and health • Rated ST-1 for Limited Smoke per UL 44 on
facilities where more stringent customer specifi- sizes 1/0 AWG and larger
cations for smoke and halogen-free materials • Stable electrical properties over a broad tem-
are desired. Ideally suited for use in a broad perature range
range of commercial, industrial and utility appli- • Excellent low temperature cold bend charac-
cations where reliability is a major concern, teristics, meets cold bend and cold impact test
where maximum performance will be demanded at -40°C
and where space is limited. For use in free air,
raceways or direct burial in accordance with NEC. Compliances
• National Electrical Code (NEC)
Construction • “FOR CT USE” on 1/0 AWG and larger in ac-
Conductor: 14 AWG thru 1000 kcmil com- cordance with NEC
pressed tinned copper per ASTM B33, Class B • UL 44 Type RHH/RHW-2
stranding per ASTM B8 • UL 854 Type USE-2

LOW VOLTAGE CABLES


Insulation: Composite Low-Smoke, Zero-Halo- • Limited Smoke rating per UL 44 and UL 1685
gen Cross-linked Polyolefin (LSZH XLPO) col- • Compressed tinned copper per ASTM B33
ored for contrast with black Low-Smoke, Zero- • Class B stranding per ASTM B8
Halogen Cross-linked Polyolefin (LSZH XLPO) • ICEA T-33-655 smoke, halogen and acid gas re-
quirements
Print: AMERICAN WIRE GROUP LSZH TYPE • ICEA S-95-658/NEMA WC70
USE-2 OR RHH OR RHW-2 (SIZE) 600 V OIL RES
I SUN RES -40C ST1* FOR CT USE* (UL) Flame Test Compliances
DAY/MONTH/YEAR OF MFG SEQUENTIAL- • For 1/0 AWG and larger: IEEE 383, IEEE
FOOTAGE MARK* “ST1” and “FOR CT USE” on 1202/CSA FT4
1/0 AWG and larger. • UL 1685

Features Other Compliances


• Rated at 90°C wet or dry • EPA 40 CFR, Part 261 for leachable lead con-
• Low-Smoke, Zero-Halogen insulation system tent per TCLP
• Extra-tough, mechanically rugged composite • OSHA Acceptable
insulation construction • RoHS Compliant
• Low friction for easy pulling on 8 AWG and Packaging
larger Material cut to length and shipped on non-re-
• Excellent electrical, thermal and physical turnable wood reels
properties
• Excellent moisture resistance, exceeding UL Options
44 requirements • 2 kV version
• Excellent resistance to crush, compression • Bare copper conductor
cuts and heat deformation • Other stranding available
• Excellent flame resistance

Item# Size Insulation Nominal Minimum Minimum Minimum Minimum Copper Net
AWG or Thickness Conductor Average Average Average Average Weight Weight
KCMIL (mil) Diameter Insulation Insulation Jacket Jacket (lb/MFT) (lb/MFT)
(in) Thickness Diameter Thickness Diameter
(in) (in) (in) (in)
14-01XLSOH 14 7/.0242 0.07 0.030 0.14 0.015 0.17 13 24
12-01XLSOH 12 7/.0305 0.09 0.030 0.16 0.015 0.19 20 33
10-01XLSOH 10 7/.0385 0.12 0.030 0.18 0.015 0.21 32 48
8-01XLSOH 8 7/.0486 0.15 0.045 0.24 0.015 0.28 50 77
6-01XLSOH 6 7/.0612 0.18 0.045 0.28 0.030 0.35 81 122
4-01XLSOH 4 7/.0772 0.23 0.045 0.33 0.030 0.39 129 178
2-01XLSOH 2 7/.0974 0.29 0.045 0.39 0.030 0.46 205 265
1/0-01XLSOH 1/0 19/.0740 0.37 0.055 0.48 0.045 0.58 326 422
2/0-01XLSOH 2/0 19/.0837 0.41 0.055 0.53 0.045 0.63 411 518

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 241
Copyright © 2018, American Wire Group, Inc. 20150108
LSZH XLPO/LSZH XLPO
Low-Voltage Power, Unshielded 600 V
UL Type RHH/RHW-2/USE-2

Item# Size Insulation Nominal Minimum Minimum Minimum Minimum Copper Net
AWG or Thickness Conductor Average Average Average Average Weight Weight
KCMIL (mil) Diameter Insulation Insulation Jacket Jacket (lb/MFT) (lb/MFT)
(in) Thickness Diameter Thickness Diameter
(in) (in) (in) (in)
4/0-01XLSOH 4/0 19/.1055 0.52 0.055 0.64 0.045 0.74 653 785
250-01XLSOH 250 37/.0822 0.56 0.065 0.70 0.065 0.85 772 960
350-01XLSOH 350 37/.0973 0.67 0.065 0.81 0.065 0.96 1081 1299
500-01XLSOH 500 37/.1162 0.80 0.065 0.94 0.065 1.09 1542 1803
750-01XLSOH 750 61/.1109 0.97 0.080 1.15 0.065 1.31 2316 2664
1000-01XLSOH 1000 61/.1280 1.13 0.080 1.31 0.065 1.46 3806 3989
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
241 Information on this sheet subject to change without notice.
20150108 Copyright © 2018, American Wire Group, Inc.
SunGuard™ Tracker Motor Cable
UL Type PV/TC 2kV

Applications Specifications
As three-conductor power cables rated 2000 • Copper conductors conform to ASTM B-3 and
volts, 90°C in dry or wet locations for Solar PV B-8.
generation, this cable is connected to the tracker • Insulated conductors RHH/RHW-2 Type per UL
motors. Approved for installation in cable trays 44, USE-2 Type per UL 854, and PV Type per
per Article 336 of the NEC. Type TC-ER cables are UL 4703, UL 1277 Type TC-ER
approved for use in Class 1, Division 2 haz- • Cable is suitable for sunlight resistant and di-
ardous locations. Cables may be installed in rect burial applications, and is approved For
open air, in ducts or conduits, or in tray or CT Use.
trough. All cables when used in accordance with • Cable meets the requirements of ICEA S-95-
the NEC meet the requirements of OSHA. 658/NEMA WC70.

Construction Notes
Stranded copper conductors, XLP (Cross-Linked • Dimensions are approximate and subject to
Polyethylene) insulation, Method 4 phase-identi- normal manufacturing tolerances.
fied; three insulated conductors cabled together • SHIPPING TOLERANCE +/- 10%

LOW VOLTAGE CABLES


with a stranded copper grounding conductor in
one interstice, fillers as necessary, cable tape,
black sunlight-resistant PVC (Polyvinyl Chloride)
jacket overall, surface printed.

Item # Size No. of Ground Insulation Jacket Nominal Approx.


AWG Conductors Wire Thickness Thickness Conductor Weight
Size AWG (mil) (mil) OD (lb/MFT)
(in)
10-03XHPGTC2000 10 3 10 60 60 0.64 280

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 239
Copyright © 2018, American Wire Group, Inc. 20170107
NOTES
LOW VOLAGE CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
MEDIUM VOLTAGE CABLES
Table of Contents

EPR Non-Shielded 2400V MV-90 ..........................................................................................301


L824 Type C Single Conductor, Non-Shielded XLPE 5000V Airport Lighting....................302
MV-105 Copper EPR Copper Tape Shield 5kV-133%/8kV-100% Insulation Level ...............303
MV-105 Copper EPR Copper Tape Shield 15kV 133% & 100% Insulation Levels...............304
MV-105 Copper EPR Copper Tape Shield 35kV 133% & 100% Insulation Level ................305
URD 175 Mil TRXLP 15kV 100% LLDPE Jacket AEIC CS-8...................................................306
URD 175 Mil EPR 15kV 100% LLDPE Jacket AEIC CS-8.......................................................307
URD 220 Mil TRXLP 15kV 133% LLDPE Jacket AEIC CS-8...................................................308
URD 220 Mil EPR 15kV 133% LLDPE Jacket AEIC CS-8.......................................................309
URD 260 Mil TRXLP 25kV 100% LLDPE Jacket AEIC CS-8 ...................................................310
URD 260 Mil EPR 25kV 100% LLDPE Jacket AEIC CS-8 .......................................................311
URD 345 Mil EPR 35kV 100% LLDPE Jacket AEIC CS-8.......................................................313
PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable
LLDPE Jacket UL MV-90/AEIC CS8-07...............................................................................312
PowerGuard® 35kV 133% MV 420 Mil TR-XLPE AL Collection System Cable
LLDPE Jacket UL MV- 90/AEIC CS8-07 - PHYSICAL PROPERTIES ..................................318
PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable

MEDIUM VOLTAGE
XLPE Jacket UL MV-105/AEIC CS8-07 ...............................................................................315

CABLES
PowerGuard® 15kV 133% MV TR-XLPE Aluminum Collection System Cable
XLPE Jacket UL MV-105/AEIC CS8-07 ...............................................................................320
PowerGuard® 5kV-35kV AluminumTR-XLPE Tape Shield
PVC Jacket UL MV-105/AEIC CS8-07 .................................................................................314
PowerGuard® 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield w/Ground
PVC Jacket UL MV-105/AEIC CS8-07 .................................................................................316
PowerGuard® 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield w/Ground
PVC Jacket UL MV-105/AEIC CS8-07 .................................................................................317
PowerGuard® 15kV 133% Shielded Power Cable AL Conductor 220 mils
EPR Copper Tape PVC Jacket MV-105................................................................................319
PowerGuard® Testing Recommendations............................................................................321

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 300
Copyright © 2018, American Wire Group, Inc. 20170306
NOTES
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Power Cable
EPR Non-Shielded PVC Jacket
2400V MV-90

Application
These cables comply with the exception notes of NEC Article 310.6 with respect to non-shielded ca-
bles above 2000V and the requirements of Table 310.63 for wet and dry locations. Consequently,
where NEC requirements apply, this cable is suitable for use in wet and dry locations at a continu-
ous conductor operating temperature of 90°C, at an emergency overload conductor temperature of
130°C and at a short circuit conductor temperature of 250°C. These cables may be installed in duct
or conduit or properly supported aerial installations. Cables that are rated for use in cable tray ap-
plications are shown on the individual product specification sheets.

Construction
Conductors:The conductor is made up of uncoated soft, copper strands meeting the requirements
of ASTM B3. Unless otherwise specified the conductors are supplied as Class B compact per ASTM
B496.
Insulation: The insulation is ethylene-propylene rubber (EPR) extruded concentrically over the con-
ductor to the wall thickness as specified in the governing specifications listed and as shown on the
individual product specification sheets.
Jacket: A sunlight and ozone resistant jacket of polyvinylchloride (PVC) or chlorinated polyethylene
(CPE) is extruded over the single and multi conductor assembly. Optional jacket materials are avail-
able that offer enhanced ratings and performance.

Standards
1)Listed by UL as Type MV-90 per Standard 1072.
2)Conforms to ICEA S-96-659/N EMA WC71 Non-Shielded 2001 V - 5KV Cables.
3)Listed by UL For CT Use (Sizes #1/0 AWG and larger CPE jacketed).
Notes

MEDIUM VOLTAGE
NEC 2005 no longer recognizes non-shielded 5000V construction and only recognizes 2400V non-

CABLES
shielded with the specific constructions attributes included in this specification. These cables meet
the current relevant ICEA standards for 5000V non-shielded cables.

Item # Size Number of Conductor Insulation Jacket Approximate Ampacity** Approximate


AWG Strands Nominal (mil) (mil) O.D. 40°C Net Weight
or KCM O.D. (in) Ambient /MFT
(in) (lb)
2400-EPR-8 8* 7 0.14 125 80 0.62 55 215
2400-EPR-6 6* 7 0.18 125 80 0.64 75 260
2400-EPR-4 4* 7 0.23 125 80 0.69 97 330
2400-EPR-2 2 7 0.27 125 80 0.75 130 430
2400-EPR-1 1* 19 0.32 125 80 0.78 155 500
2400-EPR-1/0 1/0 19 0.34 125 80 0.81 180 585
2400-EPR-2/0 2/0 19 0.38 125 80 0.86 205 685
2400-EPR-3/0 3/0 19 0.42 125 95 0.94 240 815
2400-EPR-4/0 4/0 19 0.48 125 95 0.99 280 1010
2400-EPR-250 250 37 0.52 140 110 1.11 315 1190
2400-EPR-350 350 37 0.62 140 110 1.21 385 1590
2400-EPR-500 500 37 0.74 140 110 1.33 475 2120
2400-EPR-750 750 61 0.91 155 125 1.58 600 3090
2400-EPR-1000 1000* 61 1.12 155 125 1.79 690 3950
*Compressed conductors.
**Based on three single conductor cables in isolated conduit in air per NEC tolerances.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 301
Copyright © 2018, American Wire Group, Inc. 20140917
NOTES
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
L824 Type C Airport Lighting Cables
Single Conductor, Non-Shielded XLPE
5000V

Application
For runway, taxiway and approach in underground series airport lighting circuits. At 5000 V rated
voltage and maximum conductor temperatures of 90°C for continuous normal operation and 250°C
for short circuit.
Suitable for use in wet or dry conditions in metallic and non-metallic conduits, ducts, aerial and di-
rect earth burial installations.

Construction
A bare copper seven wires stranded circular conductor covered with a separator tape has an ex-
truded tracking resistant XLPE (crosslinked polyethylene) insulation, non-jacketed.
Also available with conductor shield, insulation shield and / or PVC or PE jacket, upon request.
Standard supply lengths are 5000 ft / reel. Other reel lengths are available upon request.
Flexible stranding of 19 strands available.

Standards
Conforms to:
• FAA Advisory Circular (AC)150/5345-7E, Specification for L-824 Type C
• L824 Type B also available.
• NEMA WC71 / ICEA S-96-659-1999 for non-shielded cables.
Certification
• ETL Certified.
• FAA Listed as an Approved Supplier
Option

MEDIUM VOLTAGE
• Shielded
• LSOH Jacket

CABLES
Item # Conductor Number Nominal DC Resistance Separator Nominal Nominal Ampacity
Size of Strands Diameter of Conductor Tape of Insulation Diameter Underground
AWG in Conductor of Conductor @ 25°C Thickness (in) (in) in Duct
(in) /MFT (mil)
ALC-8 8 7 0.143 0.652 0.5 110 0.364 64
ALC-6 6 7 0.180 0.411 0.5 110 0.401 85
ALC-4 4 7 0.226 0.258 0.5 110 0.447 110

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 302
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
MV-105 Copper EPR Copper Tape Shield
5kV-133%/8kV-100% Insulation Level

Applications
For installation in tray, trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The
cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and
electric utility installations. They may operate continuously in wet or dry locations at conductor tem-
peratures not exceeding 105°C, at not more than 140°C. for emergency overload conditions and
250°C during short-circuits. Suitable for systems rated 5kV/8kV, 133% insulation level (grounded
systems).

Construction
Copper concentrically stranded compressed conductor; triple single head extruded conductor
shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry
cured; bare copper tape shielded; surface printed black PVC jacket.

Standards
• National Electrical Code (NEC)
• UL-1072 MV-105
• ICEA S-93-639/NEMA WC74
• ICEA S-97-682
• AEIC CS8
• UL listed as Type MV-105 for use in accordance with NEC
• Sizes 4/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance
with NEC
Notes
• Ampacities are based on the NEC.
• Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section

MEDIUM VOLTAGE
• Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ =
392.13; operating at 105°C conductor, at an ambient temperature of 40°C.

CABLES
90, 100% load factor.
• Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC
Table 310.73).
• CPE or CSPE Jacket available.

Item # Size Stranding Insulation Jacket Diameter Diameter Diameter Net Ampacity Ampacity Ampacity
AWG or Thickness Thickness Over Over Overall Weight 1/C 1/C 1/C
KCM (mil) (mil) Insulation Insulation (in) per in Cable Duct Conduit
(in) Shield 1000 ft. Tray Buried in Air
(in) (lb)
105-115E2 2 7 115 55 0.550 0.640 0.840 510 122 165 165
105-115E1 1 19 115 55 0.590 0.680 0.880 620 137 185 190
105-115E1/0 1/0 19 115 55 0.640 0.720 0.920 670 290 215 215
105-115E2/0 2/0 19 115 70 0.690 0.770 0.980 790 335 245 255
105-115E3/0 3/0 19 115 70 0.740 0.820 1.030 920 385 275 290
105-115E4/0 4/0 19 115 70 0.800 0.870 1.080 1080 445 315 330
105-115E250 250 37 115 70 0.860 0.930 1.140 1230 495 345 365
105-115E350 350 37 115 70 0.960 1.030 1.240 1580 610 415 440
105-115E500 500 37 115 70 1.080 1.170 1.370 2090 765 500 535
105-115E750 750 61 115 70 1.270 1.360 1.560 2950 990 610 655
105-115E1000 1000 61 115 70 1.420 1.510 1.710 3910 1185 690 755

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 303
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
MV-105 220 Mil EPR Copper Tape Shield
15kV 133% & 100% Insulation Levels

Applications
For installation in tray, trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The
cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and
electric utility installations. They may operate continuously in wet or dry locations at conductor tem-
peratures not exceeding 105°C, at not more than 140°C. for emergency overload conditions and
250°C during short-circuits. Suitable for systems rated 15 kV, 133% & 100% insulation level
(grounded systems).

Construction
Copper concentrically stranded compressed conductor; triple single head extruded conductor
shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry
cured; bare copper tape shielded; surface printed black PVC jacket.

Standards
• National Electrical Code (NEC)
• UL-1072 MV-105
• ICEA S-93-639/NEMA WC74
• ICEA S-97-682
• AEIC CS8
• UL listed as Type MV-105 for use in accordance with NEC
• Sizes 4/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance
with NEC
Notes
• Ampacities are based on the NEC.
• Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section

MEDIUM VOLTAGE
• Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ =
392.13; operating at 105°C conductor, at an ambient temperature of 40°C.

CABLES
90, 100% load factor.
• Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC
Table 310.73).
• CPE or CSPE Jacket available.

Item # Size Stranding Insulation Jacket Diameter Diameter Diameter Net Ampacity Ampacity Ampacity
AWG or Thickness Thickness Over Over Overall Weight 1/C 1/C 1/C
KCM (mil) (mil) Insulation Insulation (in) per in Cable Duct Conduit
(in) Shield 1000 ft. Tray Buried in Air
(in) (lb)
220 Mils EPR 133%
105-220E2 2 7 220 70 0.790 0.860 1.080 700 122 165 165
105-220E1/0 1/0 19 220 70 0.870 0.920 1.140 870 290 215 215
105-220E2/0 2/0 19 220 70 0.910 0.910 1.180 930 335 245 255
105-220E3/0 3/0 19 220 70 0.960 1.010 1.230 1070 385 275 290
105-220E4/0 4/0 19 220 70 1.020 1.080 1.290 1250 445 315 330
105-220E250 250 37 220 70 1.080 1.140 1.350 1420 495 345 365
105-220E350 350 37 220 70 1.180 1.240 1.470 1800 610 415 440
105-220E500 500 37 220 70 1.310 1.370 1.600 2360 756 500 535
105-220E750 750 61 220 100 1.500 1.560 1.790 3360 990 610 655
105-220E1000 1000 61 220 100 1.650 1.730 2.020 4290 1185 690 755

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 304
Copyright © 2018, American Wire Group, Inc. 20140921
MV-105 220 Mil EPR Copper Tape Shield
15kV 133% & 100% Insulation Levels

Item # Size Stranding Insulation Jacket Diameter Diameter Diameter Net Ampacity Ampacity Ampacity
AWG or Thickness Thickness Over Over Overall Weight 1/C 1/C 1/C
KCM (mil) (mil) Insulation Insulation (in) per in Cable Duct Conduit
(in) Shield 1000 ft. Tray Buried in Air
(in) (lb)
175 Mils EPR 100%
105-175E2 2 7 175 70 0.700 0.770 1.000 620 122 165 165
105-175E1/0 1/0 19 175 70 0.780 0.860 1.050 780 290 215 215
105-175E2/0 2/0 19 175 70 0.820 0.900 1.090 680 335 245 255
105-175E3/0 3/0 19 175 70 0.870 0.950 1.140 1000 385 275 290
105-175E4/0 4/0 19 175 70 0.930 1.010 1.200 1170 445 315 330
105-175E250 250 37 175 70 0.990 1.070 1.260 1320 495 345 365
105-175E350 350 37 175 70 1.090 1.190 1.380 1720 610 415 440
105-175E500 500 37 175 70 1.220 1.320 1.510 2270 756 500 535
105-175E750 750 61 175 100 1.410 1.510 1.700 3140 990 610 655
105-175E1000 1000 61 175 100 1.560 1.680 1.930 4170 1185 690 755
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
304 Information on this sheet subject to change without notice.
20140921 Copyright © 2018, American Wire Group, Inc.
MV-105 Copper EPR Copper Tape Shield
35kV 133% & 100% Insulation Level

Applications
For installation in tray, trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The
cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and
electric utility installations. They may operate continuously in wet or dry locations at conductor tem-
peratures not exceeding 105°C, at not more than 140°C for emergency overload conditions and
250°C during short-circuits. Suitable for systems rated 35 kV, 133% & 100% insulation level
(grounded systems).

Construction
Copper concentrically stranded compressed conductor; triple single head extruded conductor
shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry
cured; bare copper tape shielded; surface printed black PVC jacket.

Standards
• National Electrical Code (NEC)
• UL-1072 MV-105
• ICEA S-93-639/NEMA WC74
• ICEA S-97-682
• AEIC CS8
• UL listed as Type MV-105 for use in accordance with NEC
• Sizes 4/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance
with NEC
Notes
• Ampacities are based on the NEC.
• Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section

MEDIUM VOLTAGE
• Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ =
392.13; operating at 105°C conductor, at an ambient temperature of 40°C.

CABLES
90, 100% load factor.
• Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC
Table 310.73).

Item # Size Stranding Minimum Minimum Diameter Diameter Diameter Net Ampacity Ampacity Ampacity
AWG or Point Point Over Over Overall Weight 1/C 1/C 1/C
KCM Insulation Jacket Insulation Insulation (in) /MFT in Cable Duct Conduit
(mil) (mil) (in) Shield (lb) Tray Buried in Air
(in)
420 Mils EPR 133%
105-420E1/0 1/0 19 420 70 1.250 1.340 1.550 1370 N/A 215 215
105-420E2/0 2/0 19 420 70 1.310 1.390 1.600 1500 N/A 245 255
105-420E3/0 3/0 19 420 70 1.360 1.450 1.650 1650 N/A 275 290
105-420E4/0 4/0 19 420 70 1.410 1.500 1.710 1840 445 315 330
105-420E250 250 37 420 100 1.470 1.570 1.840 2140 495 345 365
105-420E350 350 37 420 100 1.580 1.680 1.930 2590 610 415 440
105-420E500 500 37 420 100 1.700 1.820 2.070 3240 765 500 535
105-420E750 750 61 420 100 1.890 2.010 2.280 4260 990 610 655
105-420E1000 1000 61 420 100 2.040 2.160 2.430 5230 1185 690 755

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 305
Copyright © 2018, American Wire Group, Inc. 20140921
MV-105 Copper EPR Copper Tape Shield
35kV 133% & 100% Insulation Level

Item # Size Stranding Minimum Minimum Diameter Diameter Diameter Net Ampacity Ampacity Ampacity
AWG or Point Point Over Over Overall Weight 1/C 1/C 1/C
KCM Insulation Jacket Insulation Insulation (in) /MFT in Cable Duct Conduit
(mil) (mil) (in) Shield (lb) Tray Buried in Air
(in)
345 mils EPR 100%
105-345E1/0 1/0 19 345 70 1.110 1.200 1.390 1180 N/A 215 215
105-345E2/0 2/0 19 345 70 1.150 1.250 1.440 1300 N/A 245 255
105-345E3/0 3/0 19 345 70 1.200 1.290 1.490 1460 N/A 275 290
105-345E4/0 4/0 19 345 70 1.260 1.340 1.550 1650 445 315 330
105-345E250 250 37 345 70 1.330 1.420 1.600 1830 495 345 365
105-345E350 350 37 345 100 1.430 1.520 1.780 2230 610 415 440
105-345E500 500 37 345 100 1.550 1.660 1.910 2930 765 500 535
105-345E750 750 61 345 100 1.740 1.860 2.120 3960 990 610 655
105-345E1000 1000 61 345 100 1.890 2.020 2.270 4920 1185 690 755
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
305 Information on this sheet subject to change without notice.
20140921 Copyright © 2018, American Wire Group, Inc.
URD 175 Mil TRXLP 15 kV 100%
LLDPE Jacket AEIC CS-8

Applications
For use on single phase and three phase primary underground distribution systems operating at
15kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in
ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable
insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable
as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
• AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV
• ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
• ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
• ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Lon-
gitudinal Water Blocked Cables
• UL-1072 MV90
Options
• EPR insulation
• Filled strand
• Cable core water blocking
Notes
• Ampacities are based on the NEC.
• Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section

MEDIUM VOLTAGE
• Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ =
392.13; operating at 105°C conductor, at an ambient temperature of 40°C.

CABLES
90, 100% load factor.
• Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC
Table 310.73).
• Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

Item # Code Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.
Name Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Aluminum Conductor
175-TRXPL-01 Arch 2 Solid 10 14 0.258 0.670 0.750 0.878 0.978 356 477 170 115 100
175-TRXPL-02 Cezanne 2 7 10 14 0.283 0.695 0.775 0.903 1.003 370 487 170 115 100
175-TRXPL-03 Soffit 1 Solid 13 14 0.289 0.700 0.780 0.908 1.008 424 543 195 140 123
175-TRXPL-04 Botticelli 1 19 13 14 0.322 0.730 0.810 0.938 1.038 437 556 195 140 123
175-TRXPL-05 Joists 1/0 Solid 16 14 0.325 0.735 0.815 0.943 1.043 494 615 230 155 135
175-TRXPL-06 Van Gogh 1/0 19 16 14 0.362 0.770 0.850 0.978 1.078 510 632 230 155 135
175-TRXPL-07 Goya 2/0 19 13 12 0.405 0.815 0.895 1.057 1.157 616 760 270 185 162
175-TRXPL-08 El Greco 3/0 19 16 12 0.456 0.865 0.945 1.107 1.207 730 874 295 210 184
175-TRXPL-09 Corot 4/0 19 20 12 0.512 0.920 1.000 1.162 1.262 875 1030 335 240 210
1/3 Neutral Aluminum Conductor
175-TRXLP-10 Gable 1/0 Solid 6 14 0.325 0.735 0.815 0.943 1.043 356 460 230 165 145
175-TRXLP-11 N/A 1/0 19 6 14 0.362 0.770 0.850 0.978 1.078 373 515 230 165 145
175-TRXLP-12 N/A 2/0 19 7 14 0.405 0.815 0.895 1.023 1.123 434 575 250 190 167
175-TRXLP-13 N/A 3/0 19 9 14 0.456 0.865 0.945 1.073 1.173 510 655 280 215 189
175-TRXLP-14 N/A 4/0 19 11 14 0.512 0.920 1.000 1.128 1.228 598 759 320 245 215
175-TRXLP-15 Degas 250 37 13 14 0.558 0.980 1.060 1.188 1.288 684 889 345 270 237
175-TRXLP-16 Hals 350 37 11 12 0.660 1.080 1.200 1.362 1.462 913 1175 405 325 285
175-TRXLP-17 Bosch 500 37 16 12 0.789 1.210 1.330 1.492 1.562 1207 1498 460 385 338
175-TRXLP-18 Vernet 750 61 15 10 0.968 1.400 1.520 1.724 1.884 1685 2057 515 475 417
175-TRXLP-19 N/A 1000 61 20 10 1.117 1.545 1.705 1.909 2.069 2210 2516 565 540 475

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 306
Copyright © 2018, American Wire Group, Inc. 20180401
URD 175 Mil TRXLP 15 kV 100%
LLDPE Jacket AEIC CS-8

Item # Code Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.
Name Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Copper Conductor
175-TRXLP-20 Titan 2 7 16 14 0.283 0.695 0.775 0.902 1.003 642 700 225 160 140
175-TRXLP-21 Monet 1 19 13 12 0.322 0.730 0.810 0.972 1.072 504 570 260 185 162
175-TRXLP-22 Raphael 1/0 19 16 12 0.362 0.770 0.850 1.012 1.112 923 993 295 210 185
175-TRXLP-23 Rubens 2/0 19 20 12 0.405 0.815 0.895 1.057 1.157 1107 1176 330 240 210
175-TRXLP-24 Bruegel 3/0 19 25 12 0.456 0.865 0.945 1.107 1.207 1334 1402 375 270 237
175-TRXLP-25 N/A 4/0 19 32 12 0.512 0.920 1.000 1.162 1.262 1642 1708 430 305 268
1/3 Neutral Copper Conductor
175-TRXLP-26 N/A 1/0 19 9 14 0.362 0.770 0.850 0.978 1.078 708 777 290 210 185
175-TRXLP-27 N/A 2/0 19 11 14 0.405 0.815 0.899 1.023 1.123 836 907 320 240 210
175-TRXLP-28 N/A 3/0 19 14 14 0.456 0.865 0.945 1.073 1.173 1002 1074 350 275 241
175-TRXLP-29 Holbein 4/0 19 11 12 0.512 0.920 1.000 1.162 1.262 1227 1317 390 315 276
175-TRXLP-30 Moreau 250 37 13 12 0.558 0.980 1.060 1.222 1.322 1427 1546 415 340 298
175-TRXLP-31 McNeil 350 37 12 10 0.660 1.080 1.200 1.404 1.504 1904 2055 475 415 364
175-TRXLP-32 Daumier 500 37 17 10 0.789 1.210 1.330 1.534 1.694 2664 2823 525 480 420
175-TRXLP-33 N/A 750 61 25 10 0.968 1.400 1.520 1.724 1.884 3794 3964 560 530 465
175-TRXLP-34 N/A 1000 61 33 10 1.117 1.545 1.705 1.945 2.106 4948 5127 600 590 518
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
306 Information on this sheet subject to change without notice.
201480401 Copyright © 2018, American Wire Group, Inc.
URD 175 Mil EPR 15 kV 100%
LLDPE Jacket AEIC CS-8

Applications
For use on single phase and three phase primary underground distribution systems operating at
15kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts.

Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield,
all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric
neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.

Standards
• AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV
• ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
• ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
• ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Lon-
gitudinal Water Blocked Cables
• UL-1072 MV90
Notes.
• Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

Item # Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.

MEDIUM VOLTAGE
Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.

CABLES
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Aluminum Conductor
175-EPR-01 2 Solid 10 14 0.258 0.670 0.750 0.878 0.978 451 512 170 115 100
175-EPR-02 2 7 10 14 0.290 0.690 0.750 0.880 0.980 455 518 170 115 100
175-EPR-03 1 Solid 13 14 0.289 0.700 0.780 0.908 1.008 520 581 195 140 123
175-EPR-04 1 19 13 14 0.330 0.730 0.800 0.930 1.030 536 600 195 140 123
175-EPR-05 1/0 Solid 16 14 0.325 0.735 0.815 0.943 1.043 594 656 230 155 135
175-EPR-06 1/0 19 16 14 0.370 0.770 0.840 0.970 1.070 615 680 230 155 135
175-EPR-07 2/0 19 13 12 0.420 0.820 0.880 1.010 1.110 732 810 270 185 162
175-EPR-08 3/0 19 16 12 0.470 0.870 0.930 1.100 1.200 848 927 295 210 184
175-EPR-09 4/0 19 20 12 0.530 0.930 0.990 1.150 1.260 1009 1090 335 240 210
1/3 Neutral Aluminum Conductor
175-EPR-10 1/0 Solid 6 14 0.325 0.735 0.815 0.943 1.043 471 539 230 165 145
175-EPR-11 1/0 19 6 14 0.370 0.770 0.840 0.970 1.070 482 547 230 165 145
175-EPR-12 2/0 19 7 14 0.420 0.820 0.880 0.010 1.110 552 630 250 190 167
175-EPR-13 3/0 19 9 14 0.470 0.870 0.930 0.100 1.200 630 709 280 215 189
175-EPR-14 4/0 19 11 14 0.530 0.930 0.990 0.130 1.230 737 818 320 245 215
175-EPR-15 250 37 13 14 0.570 0.990 1.050 0.170 1.270 849 959 345 270 237
175-EPR-16 350 37 11 12 0.680 1.090 1.190 0.360 1.460 1111 1253 405 325 285
175-EPR-17 500 37 16 12 0.810 1.220 1.330 1.490 1.590 1442 1590 460 385 338
175-EPR-18 750 61 15 10 0.990 1.410 1.520 1.720 1.890 1959 2149 515 475 417
175-EPR-19 1000 61 20 10 1.140 1.570 1.710 1.920 2.030 2524 2727 565 540 475

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 307
Copyright © 2018, American Wire Group, Inc. 20180401
URD 175 Mil EPR 15 kV 100%
LLDPE Jacket AEIC CS-8

Item # Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.
Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Copper Conductor
175-EPR-20 2 7 16 14 0.290 0.690 0.750 0.880 0.980 677 740 225 160 140
175-EPR-21 1 19 13 12 0.330 0.730 0.800 0.930 1.030 811 875 260 210 185
175-EPR-22 1/0 19 16 12 0.370 0.770 0.840 0.970 1.070 960 1025 295 210 185
175-EPR-23 2/0 19 20 12 0.420 0.820 0.880 1.010 1.110 1166 1244 330 240 210
175-EPR-24 3/0 19 25 12 0.470 0.870 0.930 1.100 1.200 1398 1477 375 270 237
175-EPR-25 4/0 19 32 12 0.530 0.930 0.990 1.150 1.260 1703 1784 430 305 268
1/3 Neutral Copper Conductor
175-EPR-26 1/0 19 9 14 0.370 0.770 0.840 0.970 1.070 749 814 290 210 185
175-EPR-27 2/0 19 11 14 0.420 0.820 0.880 1.010 1.110 891 969 320 240 210
175-EPR-28 3/0 19 14 14 0.470 0.870 0.930 1.100 1.200 1056 1135 350 275 241
175-EPR-29 4/0 19 11 12 0.530 0.930 0.990 1.150 1.250 1267 1348 390 315 276
175-EPR-30 250 37 13 12 0.570 0.990 1.050 1.190 1.290 1487 1597 415 340 298
175-EPR-31 350 37 12 10 0.680 1.090 1.190 1.360 1.460 2022 2164 475 415 364
175-EPR-32 500 37 17 10 0.810 1.220 1.330 1.490 1.590 2712 2860 525 480 420
175-EPR-33 750 61 25 10 0.990 1.410 1.520 1.720 1.890 3873 4063 560 530 465
175-EPR-34 1000 61 33 10 1.140 1.570 1.710 1.920 2.030 5028 5231 600 590 518
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
307 Information on this sheet subject to change without notice.
20180401 Copyright © 2018, American Wire Group, Inc.
URD 220 Mil TRXLP 15kV 133%
LLDPE Jacket AEIC CS-8

Applications
For use on single phase and three phase primary underground distribution systems operating at
15kV phase to phase at 100% and 133% insulation level. Suitable for either direct burial or installa-
tion in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable
insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a con-
centric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
• AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
• ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
• ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
• ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Lon-
gitudinal Water Blocked Cables
• UL-1072 MV90
Options
• EPR insulation
• Filled strand
• Cable core water blocking
Notes
• Ampacities are based on the NEC.
• Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section

MEDIUM VOLTAGE
• Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ =
392.13; operating at 105°C conductor, at an ambient temperature of 40°C.

CABLES
90, 100% load factor.
• Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC
Table 310.73).
• Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

Item # Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.
Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Aluminum Conductor
220-TRXLP-01 2 Solid 10 14 0.258 0.760 0.840 0.968 1.068 401 537 170 115 100
220-TRXLP-02 2 7 10 14 0.283 0.785 0.865 0.993 1.093 415 549 170 115 100
220-TRXLP-03 1 Solid 13 14 0.289 0.790 0.870 0.998 1.098 470 604 195 140 123
220-TRXLP-04 1 19 13 14 0.322 0.820 0.900 1.028 1.128 487 619 195 140 123
220-TRXLP-05 1/0 Solid 16 14 0.325 0.825 0.905 1.033 1.133 544 680 230 155 135
220-TRXLP-06 1/0 19 16 14 0.362 0.860 0.940 1.068 1.168 562 697 230 155 135
220-TRXLP-07 2/0 19 13 12 0.405 0.905 0.985 1.147 1.247 670 830 270 185 162
220-TRXLP-08 3/0 19 16 12 0.456 0.955 1.035 1.197 1.297 787 946 295 210 184
220-TRXLP-09 4/0 19 20 12 0.512 1.010 1.090 1.252 1.352 934 1148 335 240 210
1/3 Neutral Aluminum Conductor
220-TRXLP-10 1/0 Solid 6 14 0.325 0.825 0.905 1.033 1.133 423 562 230 165 145
220-TRXLP-11 1/0 19 6 14 0.362 0.860 0.940 1.068 1.168 441 580 230 165 145
220-TRXLP-12 2/0 19 7 14 0.405 0.905 0.985 1.113 1.213 490 643 250 190 167
220-TRXLP-13 3/0 19 9 14 0.456 0.955 1.035 1.163 1.263 567 725 280 215 189
220-TRXLP-14 4/0 19 11 14 0.512 1.010 1.090 1.218 1.318 656 842 320 245 215
220-TRXLP-15 250 37 13 14 0.558 1.070 1.190 1.318 1.418 781 1013 345 270 237
220-TRXLP-16 350 37 11 12 0.660 1.170 1.290 1.452 1.612 987 1266 405 325 285
220-TRXLP-17 500 37 16 12 0.789 1.300 1.420 1.582 1.742 1284 1597 460 385 338
220-TRXLP-18 750 61 15 10 0.968 1.490 1.610 1.814 1.974 1774 2230 515 475 417
220-TRXLP-19 1000 61 20 10 1.117 1.635 1.795 1.999 2.159 2301 2718 565 540 475

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 308
Copyright © 2018, American Wire Group, Inc. 20180401
URD 220 Mil TRXLP 15kV 133%
LLDPE Jacket AEIC CS-8

Item # Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.
Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Copper Conductor
220-TRXLP-20 2 7 16 14 0.283 0.785 0.865 0.993 1.093 695 760 225 160 140
220-TRXLP-21 1 19 13 12 0.322 0.820 0.900 1.062 1.162 559 633 260 185 162
220-TRXLP-22 1/0 19 16 12 0.362 0.860 0.940 1.102 1.202 982 1060 295 210 185
220-TRXLP-23 2/0 19 20 12 0.405 0.905 0.985 1.147 1.247 1169 1246 330 240 210
220-TRXLP-24 3/0 19 25 12 0.456 0.955 1.035 1.197 1.293 1399 1475 375 270 237
220-TRXLP-25 4/0 19 32 12 0.512 1.010 1.090 1.294 1.394 1747 1825 430 305 268
1/3 Neutral Copper Conductor
220-TRXLP-26 1/0 19 9 14 0.362 0.860 0.940 1.068 1.168 767 842 290 210 185
220-TRXLP-27 2/0 19 11 14 0.405 0.905 0.985 1.113 1.213 897 975 320 240 210
220-TRXLP-28 3/0 19 14 14 0.456 0.955 1.035 1.163 1.263 1066 1145 350 275 241
220-TRXLP-29 4/0 19 11 12 0.512 1.010 1.090 1.294 1.394 1333 1434 390 315 276
220-TRXLP-30 250 37 13 12 0.558 1.070 1.190 1.352 1.452 1539 1673 415 340 298
220-TRXLP-31 350 37 12 10 0.660 1.170 1.290 1.494 1.654 1987 2149 475 415 364
220-TRXLP-32 500 37 17 10 0.789 1.300 1.420 1.624 1.784 2754 2924 525 480 420
220-TRXLP-33 750 61 25 10 0.968 1.490 1.610 1.814 1.974 3952 4138 560 530 465
220-TRXLP-34 1000 61 33 10 1.117 1.635 1.795 1.999 2.159 5061 5251 600 590 518
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
308 Information on this sheet subject to change without notice.
20180401 Copyright © 2018, American Wire Group, Inc.
URD 220 Mil EPR 15kV 133%
LLDPE Jacket AEIC CS-8

Applications
For use on single phase and three phase primary underground distribution systems operating at
15kV phase to phase at 100% and 133% insulation level. Suitable for either direct burial or installa-
tion in ducts.

Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield,
all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral;
LLDPE jacket with extruded longitudinal colored stripes, surface printed.

Standards
• AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
• ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
• ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
• ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Lon-
gitudinal Water Blocked Cables
• UL-1072 MV90
Notes
• Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

Item # Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.

MEDIUM VOLTAGE
Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.

CABLES
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Aluminum Conductor
220-EPR-01 2 Solid 10 14 0.258 0.760 0.840 0.968 1.068 518 585 170 115 100
220-EPR-02 2 7 10 14 0.290 0.780 0.840 0.970 1.075 534 603 170 115 100
220-EPR-03 1 Solid 13 14 0.289 0.790 0.870 0.998 1.098 587 655 195 140 123
220-EPR-04 1 19 13 14 0.330 0.830 0.890 1.020 1.121 606 676 195 140 123
220-EPR-05 1/0 Solid 16 14 0.325 0.825 0.905 1.033 1.133 665 733 230 155 135
220-EPR-06 1/0 19 16 14 0.370 0.870 0.930 1.060 1.161 691 764 230 155 135
220-EPR-07 2/0 19 13 12 0.420 0.910 0.980 1.100 1.207 808 895 270 185 162
220-EPR-08 3/0 19 16 12 0.470 0.960 1.030 1.190 1.291 926 1015 295 210 184
220-EPR-09 4/0 19 20 12 0.530 1.020 1.120 1.290 1.389 1135 1228 335 240 210
1/3 Neutral Aluminum Conductor
220-EPR-10 1/0 Solid 6 14 0.325 0.825 0.905 1.033 1.133 541 616 230 165 145
220-EPR-11 1/0 19 6 14 0.370 0.870 0.930 1.060 1.161 558 631 230 165 145
220-EPR-12 2/0 19 7 14 0.420 0.910 0.980 1.100 1.207 628 715 250 190 167
220-EPR-13 3/0 19 9 14 0.470 0.960 1.030 1.190 1.291 708 797 280 215 189
220-EPR-14 4/0 19 11 14 0.530 1.020 1.120 1.270 1.369 863 956 320 245 215
220-EPR-15 250 37 13 14 0.570 1.080 1.180 1.370 1.469 978 1092 345 270 237
220-EPR-16 350 37 11 12 0.680 1.180 1.290 1.450 1.552 1219 1369 405 325 285
220-EPR-17 500 37 16 12 0.810 1.310 1.420 1.580 1.746 1555 1715 460 385 338
220-EPR-18 750 61 15 10 0.990 1.510 1.610 1.810 1.980 2144 2349 515 475 417
220-EPR-19 1000 61 20 10 1.140 1.660 1.810 2.010 2.175 2667 2882 565 540 475

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 309
Copyright © 2018, American Wire Group, Inc. 20180401
URD 220 Mil EPR 15kV 133%
LLDPE Jacket AEIC CS-8

Item # Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.
Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Copper Conductor
220-EPR-20 2 7 16 14 0.290 0.780 0.840 0.970 1.075 756 825 225 160 140
220-EPR-21 1 19 13 12 0.330 0.830 0.890 1.040 1.141 881 951 260 185 162
220-EPR-22 1/0 19 16 12 0.370 0.870 0.930 1.080 1.181 1036 1109 295 210 185
220-EPR-23 2/0 19 20 12 0.420 0.910 0.980 1.100 1.207 1242 1329 330 240 210
220-EPR-24 3/0 19 25 12 0.470 0.960 1.030 1.190 1.291 1476 1565 375 270 237
220-EPR-25 4/0 19 32 12 0.530 1.020 1.120 1.290 1.389 1829 1922 430 305 268

1/3 Neutral Copper Conductor


220-EPR-26 1/0 19 9 14 0.370 0.870 0.930 1.080 1.181 825 898 290 210 185
220-EPR-27 2/0 19 11 14 0.420 0.910 0.980 1.100 1.207 967 1054 320 240 210
220-EPR-28 3/0 19 14 14 0.470 0.960 1.030 1.190 1.291 1134 1223 350 275 241
220-EPR-29 4/0 19 11 12 0.530 1.020 1.120 1.310 1.410 1393 1486 390 315 276
220-EPR-30 250 37 13 12 0.570 1.080 1.180 1.410 1.509 1616 1730 415 340 298
220-EPR-31 350 37 12 10 0.680 1.180 1.290 1.490 1.592 2130 2280 475 415 364
220-EPR-32 500 37 17 10 0.810 1.310 1.420 1.620 1.786 2825 2985 525 480 420
220-EPR-33 750 61 25 10 0.990 1.510 1.610 1.810 1.980 4058 4263 560 530 465
MEDIUM VOLAGE

220-EPR-34 1000 61 33 10 1.140 1.660 1.810 2.010 2.175 5171 5386 600 590 518
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
309 Information on this sheet subject to change without notice.
20180401 Copyright © 2018, American Wire Group, Inc.
URD 260 Mil TRXLP 25kV 100%
LLDPE Jacket AEIC CS-8

Applications
For use on single phase and three phase primary underground distribution systems operating at
25kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in
ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, TRXLPE (tree-retardant cross-linked polyethylene insulation and easy strippable
insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable
as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
• AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
• ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
• ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
• ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Lon-
gitudinal Water Blocked Cables
• UL-1072 MV90
Options
• EPR insulation
• Filled strand
• Cable core water blocking
Notes
• Ampacities are based on the NEC.
• Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section

MEDIUM VOLTAGE
• Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ =
392.13; operating at 105°C conductor, at an ambient temperature of 40°C.

CABLES
90, 100% load factor.
• Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC
Table 310.73).
• Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

Item # Code Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.
Name Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Aluminum Conductor
260-TRXLP-01 N/A 1 Solid 13 14 0.289 0.870 0.950 1.078 1.178 518 671 195 145 127
260-TRXLP-02 Liszt 1 19 13 14 0.322 0.900 0.980 1.108 1.208 535 687 195 145 127
260-TRXLP-03 N/A 1/0 Solid 16 14 0.325 0.905 0.989 1.117 1.217 590 748 220 165 145
260-TRXLP-04 Verdi 1/0 19 16 14 0.362 0.940 1.022 1.150 1.250 614 767 220 165 145
260-TRXLP-05 Ives 2/0 19 13 12 0.405 0.985 1.065 1.227 1.327 722 905 250 190 167
260-TRXLP-06 Bach 3/0 19 16 12 0.456 1.035 1.155 1.317 1.417 875 1065 290 210 185
260-TRXLP-07 Mozart 4/0 19 20 12 0.512 1.090 1.210 1.372 1.472 1025 1241 325 245 215
1/3 Neutral Aluminum Conductor
260-TRXLP-08 N/A 1/0 Solid 6 14 0.325 0.905 0.989 1.117 1.217 460 631 225 165 145
260-TRXLP-09 N/A 1/0 19 6 14 0.362 0.940 1.022 1.150 1.250 475 650 225 165 145
260-TRXLP-10 N/A 2/0 19 7 14 0.405 0.985 1.065 1.193 1.293 540 715 250 180 158
260-TRXLP-11 N/A 3/0 19 9 14 0.456 1.035 1.155 1.283 1.383 655 842 275 205 180
260-TRXLP-12 N/A 4/0 19 11 14 0.512 1.090 1.210 1.338 1.438 750 966 310 240 210
260-TRXLP-13 Wagner 250 37 13 14 0.558 1.160 1.280 1.408 1.508 852 1117 335 260 228
260-TRXLP-14 Gould 350 37 11 12 0.660 1.260 1.380 1.542 1.702 1060 1380 395 325 285
260-TRXLP-15 Schubert 500 37 16 12 0.789 1.390 1.510 1.672 1.832 1369 1721 445 390 342
260-TRXLP-16 Strauss 750 61 15 10 0.968 1.580 1.740 1.944 2.104 1920 2373 515 475 417
260-TRXLP-17 N/A 1000 61 20 10 1.117 1.725 1.885 2.089 2.249 2405 2870 560 525 460

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 310
Copyright © 2018, American Wire Group, Inc. 20180401
URD 260 Mil TRXLP 25kV 100%
LLDPE Jacket AEIC CS-8

Item # Code Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.
Name Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Copper Conductor
260-TRXLP-18 Handel 1 19 13 12 0.322 0.900 0.980 1.142 1.242 615 701 245 185 162
260-TRXLP-19 Haydn 1/0 19 16 12 0.362 0.940 1.022 1.184 1.284 1044 1133 280 215 189
260-TRXLP-20 Brahms 2/0 19 20 12 0.405 0.985 1.065 1.227 1.327 1232 1321 315 240 210
260-TRXLP-21 Ravel 3/0 19 25 12 0.456 1.035 1.155 1.317 1.417 1502 1594 360 275 241
260-TRXLP-22 Chopin 4/0 19 32 12 0.512 1.090 1.210 1.372 1.472 1828 1919 415 315 276
1/3 Neutral Copper Conductor
260-TRXLP-23 N/A 1/0 19 9 14 0.352 0.940 1.022 1.150 1.250 826 912 275 215 189
260-TRXLP-24 N/A 2/0 19 11 14 0.405 0.985 1.065 1.193 1.293 960 1048 310 250 220
260-TRXLP-25 N/A 3/0 19 14 14 0.456 1.035 1.155 1.283 1.383 1166 1261 345 285 250
260-TRXLP-26 N/A 4/0 19 11 12 0.512 1.090 1.210 1.371 1.471 1414 1528 385 320 280
260-TRXLP-27 Dufay 250 37 13 12 0.558 1.160 1.280 1.442 1.602 1628 1780 410 345 303
260-TRXLP-28 Schuetz 350 37 12 10 0.660 1.260 1.380 1.584 1.744 2083 2266 460 405 355
260-TRXLP-29 Lully 500 37 17 10 0.789 1.390 1.510 1.714 1.874 2858 3050 520 470 412
260-TRXLP-30 N/A 750 61 25 10 0.968 1.580 1.741 1.944 2.104 4071 4280 567 450 483
260-TRXLP-31 N/A 1000 61 33 10 1.117 1.725 1.885 2.089 2.249 5190 5404 625 615 540
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
310 Information on this sheet subject to change without notice.
20180401 Copyright © 2018, American Wire Group, Inc.
URD 260 Mil EPR 25kV 100%
LLDPE Jacket AEIC CS-8

Applications
For use on single phase and three phase primary underground distribution systems operating at
25kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts.

Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield,
all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral;
LLDPE jacket with extruded longitudinal colored stripes, surface printed.

Standards
• AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
• ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
• ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
• ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Lon-
gitudinal Water Blocked Cables
• UL-1072 MV90
Notes
• Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

Item # Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.

MEDIUM VOLTAGE
Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.

CABLES
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Aluminum Conductor
260-EPR-01 1 Solid 13 14 0.289 0.870 0.950 1.078 1.178 657 735 195 145 127
260-EPR-02 1 19 13 14 0.330 0.910 0.970 1.100 1.200 676 757 195 145 127
260-EPR-03 1/0 Solid 16 14 0.325 0.905 0.989 1.117 1.217 736 815 220 165 145
260-EPR-04 1/0 19 16 14 0.370 0.950 1.010 1.140 1.240 762 845 220 165 145
260-EPR-05 2/0 19 13 12 0.420 0.990 1.060 1.190 1.290 886 986 250 190 167
260-EPR-06 3/0 19 16 12 0.470 1.040 1.150 1.310 1.410 1038 1141 290 210 185
260-EPR-07 4/0 19 20 12 0.530 1.100 1.210 1.370 1.470 1233 1340 325 245 215
1/3 Neutral Aluminum Conductor
260-EPR-08 1/0 Solid 6 14 0.325 0.905 0.989 1.117 1.217 612 698 225 165 145
260-EPR-09 1/0 19 6 14 0.370 0.950 1.010 1.140 1.240 629 712 225 165 145
260-EPR-10 2/0 19 7 14 0.420 0.990 1.060 1.190 1.290 706 806 250 180 158
260-EPR-11 3/0 19 9 14 0.470 1.040 1.150 1.310 1.410 820 923 275 205 180
260-EPR-12 4/0 19 11 14 0.530 1.100 1.210 1.370 1.470 961 1068 310 240 210
260-EPR-13 250 37 13 14 0.570 1.160 1.260 1.470 1.570 1086 1229 335 260 228
260-EPR-14 350 37 11 12 0.680 1.260 1.400 1.530 1.700 1328 1500 395 325 285
260-EPR-15 500 37 16 12 0.810 1.400 1.500 1.660 1.830 1681 1865 445 390 342
260-EPR-16 750 61 15 10 0.990 1.590 1.730 1.940 2.100 2294 2528 515 475 417
260-EPR-17 1000 61 20 10 1.140 1.740 1.890 2.090 2.260 2827 3072 560 525 460

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 311
Copyright © 2018, American Wire Group, Inc. 20180401
URD 260 Mil EPR 25kV 100%
LLDPE Jacket AEIC CS-8

Item # Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.
Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Copper Conductor
260-EPR-18 1 19 13 12 0.330 0.910 0.970 1.100 1.200 951 1032 245 185 162
260-EPR-19 1/0 19 16 12 0.370 0.950 1.010 1.160 1.260 1107 1190 280 215 189
260-EPR-20 2/0 19 20 12 0.420 0.990 1.060 1.190 1.290 1320 1420 315 240 210
260-EPR-21 3/0 19 25 12 0.470 1.040 1.150 1.310 1.410 1588 1691 360 275 241
260-EPR-22 4/0 19 32 12 0.530 1.100 1.210 1.370 1.470 1927 2034 415 315 276
1/3 Neutral Copper Conductor
260-EPR-23 1/0 19 9 14 0.370 0.950 1.010 1.140 1.240 896 996 275 215 189
260-EPR-24 2/0 19 11 14 0.420 0.990 1.060 1.190 1.290 1045 1148 310 250 220
260-EPR-25 3/0 19 14 14 0.470 1.040 1.150 1.310 1.410 1246 1353 345 285 250
260-EPR-26 4/0 19 11 12 0.530 1.100 1.210 1.390 1.490 1491 1634 385 320 280
260-EPR-27 250 37 13 12 0.570 1.160 1.260 1.490 1.590 1724 1896 410 345 303
260-EPR-28 350 37 12 10 0.680 1.260 1.400 1.570 1.740 2239 2423 460 405 355
260-EPR-29 500 37 17 10 0.810 1.400 1.500 1.700 1.870 2951 3185 520 470 412
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
311 Information on this sheet subject to change without notice.
20180401 Copyright © 2018, American Wire Group, Inc.
URD 345 Mil EPR 35kV 100%
LLDPE Jacket AEIC CS-8

Applications
For use on single phase and three phase primary underground distribution systems operating at
35kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts.

Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded
conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield,
all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric
neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.

Standards
• AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
• ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
• ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked
Conductors
• ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Lon-
gitudinal Water Blocked Cables
• UL-1072 MV90
Notes
• Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

Item # Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.

MEDIUM VOLTAGE
Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.

CABLES
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Aluminum Conductor
345-EPR-01 1/0 Solid 16 14 0.325 1.075 1.195 1.323 1.423 938 1034 220 165 145
345-EPR-02 1/0 19 16 14 0.370 1.120 1.230 1.350 1.460 968 1068 220 165 145
345-EPR-03 2/0 19 13 12 0.420 1.170 1.270 1.400 1.500 1105 1224 250 195 310
345-EPR-04 3/0 19 16 12 0.470 1.220 1.320 1.480 1.590 1236 1356 285 220 193
345-EPR-05 4/0 19 20 12 0.530 1.280 1.380 1.540 1.710 1433 1558 325 250 220
1/3 Neutral Aluminum Conductor
345-EPR-06 1/0 Solid 6 14 0.325 1.075 1.195 1.323 1.423 736 815 215 165 145
345-EPR-07 1/0 19 6 14 0.370 1.120 1.230 1.350 1.460 835 935 215 165 145
345-EPR-08 2/0 19 7 14 0.420 1.170 1.270 1.400 1.500 925 1044 245 190 167
345-EPR-09 3/0 19 9 14 0.470 1.220 1.320 1.480 1.590 1018 1138 275 215 189
345-EPR-10 4/0 19 11 14 0.530 1.280 1.380 1.540 1.710 1161 1286 305 245 215
345-EPR-11 250 37 13 14 0.570 1.330 1.440 1.640 1.810 1301 1484 335 270 238
345-EPR-12 350 37 11 12 0.680 1.440 1.540 1.700 1.890 1558 1752 390 320 280
345-EPR-13 500 37 16 12 0.810 1.570 1.720 1.880 2.040 2003 2213 440 385 338
345-EPR-14 750 61 15 10 0.990 1.760 1.930 2.110 2.280 2590 2850 515 475 417
345-EPR-15 1000 61 20 10 1.140 1.920 2.060 2.270 2.430 3143 3415 570 535 470

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 313
Copyright © 2018, American Wire Group, Inc. 20180401
URD 345 Mil EPR 35kV 100%
LLDPE Jacket AEIC CS-8

Item # Cond. Cond. Copper Copper Conductor Diameter Diameter Diameter Diameter Total Total Ampacity Ampacity Ampacity.
Size Stranding Neutral Neutral Diameter Over Over Over Over w/o w/Embedded 1/C 1/C 1/C
AWG No.of Size Insulation Insulation Neutral Embedded Jacket Jacket in Cable Duct Conduit.
Wires AWG (in) Shield Wires Jacket Weight Weight Tray Buried in Air
(in) (in) (in) (lb) (lb)
Full Neutral Copper Conductor
345-EPR-16 1/0 19 16 12 0.370 1.120 1.230 1.350 1.460 1313 1413 280 215 189
345-EPR-17 2/0 19 20 12 0.420 1.170 1.270 1.400 1.500 1539 1658 310 240 211
345-EPR-18 3/0 19 25 12 0.470 1.220 1.320 1.480 1.590 1786 1906 355 275 241
345-EPR-19 4/0 19 32 12 0.530 1.280 1.380 1.540 1.710 2127 2252 410 315 276
1/3 Neutral Copper Conductor
345-EPR-20 1/0 19 9 14 0.370 1.120 1.230 1.350 1.460 1102 1221 270 215 189
345-EPR-21 2/0 19 11 14 0.420 1.170 1.270 1.400 1.500 1264 1384 305 240 211
345-EPR-22 3/0 19 14 14 0.470 1.220 1.320 1.480 1.590 1444 1569 340 280 246
345-EPR-23 4/0 19 11 12 0.530 1.280 1.380 1.540 1.710 1691 1874 380 315 276
345-EPR-24 250 37 13 12 0.570 1.330 1.440 1.640 1.810 1939 2133 405 340 298
345-EPR-25 350 37 12 10 0.680 1.440 1.540 1.700 1.890 2469 2679 460 400 350
345-EPR-26 500 37 17 10 0.810 1.570 1.720 1.880 2.040 3273 3533 520 470 412
345-EPR-27 750 61 25 10 0.990 1.760 1.930 2.110 2.280 4504 4776 567 550 483
345-EPR-28 1000 61 33 10 1.140 1.920 2.060 2.270 2.430 5647 5647 625 615 540
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
313 Information on this sheet subject to change without notice.
20180401 Copyright © 2018, American Wire Group, Inc.
PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable
LLDPE Jacket UL MV-90/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Applications
PowerGuard® cables are intended for use in wet or dry locations for distribution of single or three
phase medium-voltage power. These cables may be installed in ducts or direct buried.

Description
Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation
system consisting of a thermosetting semiconducting conductor shield, high dielectric strength
PowerGuardTRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric
neutral wires, water blocking agents, black encapsulating linear low-density polyethylene (LLDPE)
jacket.

Construction
Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231.
Stranded conductors are water-blocked with conductor filling compound.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation.
Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S-
94-649 - 100% insulation level.
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the in-
sulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield: Solid bare copper wires helically applied and uniformly spaced.
Water Block: Water-blocking agents applied over the insulation shield and around the neutral wires
to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accor-
dance with the latest edition of ICEA T-34-664 except that the minimum requirement is 15 psig for 1
hour.

MEDIUM VOLTAGE
Jacket: Black insulating sunlight resistant linear low-density polyethylene encapsulating the neutral

CABLES
wires with three extruded red stripes and NESC lightning bolt symbol.

Insulation Temperature Rating


Normal.............................. 90°C
Emergency*.................... 130°C
Short Circuit.................... 250°C
*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during
the lifetime of the cable.

Specifications
• ASTM B-231
• AEIC CS8
• ICEA S-94-649
• ICEA T-31-610
• ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable
• UL 1072 MV-90
• CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribu-
tion
Options
• Copper Conductors
• Black LLDPE jacket with no stripes
• Multiplex cables
Factory Warranty
20 Years

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 312
Copyright © 2018, American Wire Group, Inc. 20160110
PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable
LLDPE Jacket UL MV-90/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Item # CONDUCTOR INSULATION2 CONCENTRIC NEUTRAL JACKET4 WEIGHTS


AL Size Nominal Minimum Maximum Size No. of Size of Nominal Aluminum Copper Net
AWG or Diameter1 Diameter Diameter Wires Wires Diameter Weight Weight Weight4
kcmil (in) (in) (in) (in) /MFT /MFT /MFT
(lb) (lb) (lb)
PHYSICAL PROPERTIES
UR1C1ALW-1614DA35 1/0 0.362 1.045 1.145 Full 16 14 1.41 99 209 914
UR1C1ALW-1114DA35 1/0 0.362 1.045 1.145 2/3 11 14 1.41 99 144 841
UR1C1ALW-0814DA35 1/0 0.362 1.045 1.145 1/2 8 14 1.41 99 104 812
UR1C1ALW-0614DA35 1/0 0.362 1.045 1.145 1/3 6 14 1.41 99 78 802
UR1C2ALW-2014DA35 2/0 0.408 1.090 1.190 Full 20 14 1.45 125 266 982
UR1C2ALW-1414DA35 2/0 0.408 1.090 1.190 2/3 14 14 1.45 125 187 912
UR1C2ALW-1014DA35 2/0 0.408 1.090 1.190 1/2 10 14 1.45 125 133 865
UR1C2ALW-0714DA35 2/0 0.408 1.090 1.190 1/3 7 14 1.45 125 93 852
UR1C3ALW-1612DA35 3/0 0.458 1.140 1.240 Full 16 12 1.56 157 332 1190
UR1C3ALW-1714DA35 3/0 0.458 1.140 1.240 2/3 17 14 1.50 157 222 1044
UR1C3ALW-1314DA35 3/0 0.458 1.140 1.240 1/2 13 14 1.50 157 170 951
UR1C3ALW-0914DA35 3/0 0.458 1.140 1.240 1/3 9 14 1.50 157 118 944
UR1C4ALW-2012DA35 4/0 0.515 1.195 1.295 Full 20 12 1.60 198 415 1330
UR1C4ALW-2114DA35 4/0 0.515 1.195 1.295 2/3 21 14 1.58 198 274 1171
UR1C4ALW-1614DA35 4/0 0.515 1.195 1.295 1/2 16 14 1.58 198 209 1126
UR1C4ALW-1114DA35 4/0 0.515 1.195 1.295 1/3 11 14 1.58 198 144 1074
UR1C4ALW-0614DA35 4/0 0.515 1.195 1.295 1/6 6 14 1.58 198 78 1020
UR1E5ALX-1314DA35 250 0.561 1.250 1.350 1/3 13 14 1.62 234 170 1160
MEDIUM VOLAGE

UR1E5ALX-1016DA35 250 0.561 1.250 1.350 1/6 10 16 1.60 234 84 1069


CABLES

UR1E5ALX-0616DA35 250 0.561 1.250 1.350 1/12 6 16 1.60 234 51 1033


UR1F5ALX-1609DA35 350 0.661 1.355 1.455 Full 16 9 1.90 328 667 1993
UR1F5ALX-2212DA35 350 0.661 1.355 1.455 2/3 22 12 1.81 328 458 1695
UR1F5ALX-1712DA35 350 0.661 1.355 1.455 1/2 17 12 1.81 328 354 1603
UR1F5ALX-1814DA35 350 0.661 1.355 1.455 1/3 18 14 1.77 328 235 1457
UR1F5ALX-0914DA35 350 0.661 1.355 1.455 1/6 9 14 1.77 328 117 1358
UR1F5ALX-0716DA35 350 0.661 1.355 1.455 1/12 7 16 1.74 328 59 1256
UR1H0ALX-2010DA35 500 0.790 1.480 1.580 2/3 20 10 1.98 469 662 2181
UR1H0ALX-2412DA35 500 0.790 1.480 1.580 1/2 24 12 1.95 469 498 1983
UR1H0ALX-1612DA35 500 0.790 1.480 1.580 1/3 16 12 1.95 469 332 1854
UR1H0ALX-1314DA35 500 0.790 1.480 1.580 1/6 13 14 1.92 469 170 1669
UR1H0ALX-1016DA35 500 0.790 1.480 1.580 1/12 10 16 1.89 469 84 1629
UR1J5ALY-2310DA35 750 0.968 1.670 1.770 1/2 23 10 2.20 703 761 2727
UR1J5ALY-2412DA35 750 0.968 1.670 1.770 1/3 24 12 2.16 703 498 2434
UR1J5ALY-1914DA35 750 0.968 1.670 1.770 1/6 19 14 2.14 703 248 2163
UR1J5ALY-1014DA35 750 0.968 1.670 1.770 1/12 10 14 2.14 703 133 2076
UR1K0ALY-3010DA35 1000 1.117 1.815 1.920 1/2 30 10 2.36 937 993 3311
UR1K0ALY-2010DA35 1000 1.117 1.815 1.920 1/3 20 10 2.36 937 660 3015
UR1K0ALY-1612DA35 1000 1.117 1.815 1.920 1/6 16 12 2.32 937 332 2658
UR1K0ALY-1314DA35 1000 1.117 1.815 1.920 1/12 13 14 2.27 937 173 2455
UR1M5ALZ-2510DA35 1250 1.250 1.960 2.065 1/3 25 10 2.61 1173 827 3755
UR1M5ALZ-2012DA35 1250 1.250 1.960 2.065 1/6 20 12 2.54 1173 415 3225
UR1M5ALZ-1614DA35 1250 1.250 1.960 2.065 1/12 16 14 2.49 1173 209 2984
UR1P0ALZ-2409DA35 1500 1.370 2.100 2.205 1/3 24 9 2.69 1408 1002 4036
UR1P0ALZ-2412DA35 1500 1.370 2.100 2.205 1/6 24 12 2.62 1408 497 3474
UR1P0ALZ-1914DA35 1500 1.370 2.100 2.205 1/12 19 14 2.58 1408 248 3193
1) Diameters are based on ASTM Class B Compressed diameters.
2) Extruded layer thicknesses, insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for Concentric Neutral Cables Rated 5-46kV and also meet the requirements of the latest revisions of
AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
3) Ampacity based on earth thermal resistivity of 90°C-cm/watt, 90°C conductor temperature, 20°C earth ambient temperature, 75% load factor and 36" depth of burial. Values are based on one three-phase circuit, one
conductor per phase, with neutral wires bonded at each end.
4) Cables buried in flat adjacent configuration with 7.5" spacing between conductors.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
312 Information on this sheet subject to change without notice
20160110 Copyright © 2018, American Wire Group, Inc.
PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable
LLDPE Jacket UL MV-90/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Item # CONDUCTOR NEUTRAL TREFOIL FLAT SPACED @ 7.5” FLAT SPACED TOUCHING
AL Size Size Pos./Neg. Seq1 Zero Seq1 Ampacity1 Pos./Neg Seq2 Zero Seq2 Ampacity2 Pos./Neg Seq3 Zero Seq3 Ampacity3.
AWG or Impedence Impedence Trefoil Impedence Impedence Flat Impedence Impedence Flat
kcmil (μΩ/ft) (μΩ/ft) (amps) (μΩ/ft) (μΩ/ft) (amps) (μΩ/ft) (μΩ/ft) (amps)
ELECTRICAL PROPERTIES
UR1C1ALW-1614DA35 1/0 FULL 239 + J53 414 + J81 217 255 + J90 407 + J84 232 240 + J57 412 + J81 216
UR1C1ALW-1114DA35 1/0 2/3 238 + J53 475 + J126 217 250 + J93 462 + J130 233 239 + J58 472 + J126 217
UR1C1ALW-0814DA35 1/0 1/2 238 + J53 528 + J187 217 246 + J95 506 + J191 234 238 + J58 525 + J187 217
UR1C1ALW-0614DA35 1/0 1/3 238 + J53 568 + J263 217 244 + J95 536 + J262 235 237 + J58 563 + J262 217
UR1C2ALW-2014DA35 2/0 Full 185 + J50 331 + J64 250 204 + J85 326 + J67 266 187 + J55 330 + J64 250
UR1C2ALW-1414DA35 2/0 2/3 185 + J50 384 + J94 250 199 + J89 375 + J98 268 185 + J55 382 + J94 250
UR1C2ALW-1014DA35 2/0 1/2 184 + J51 440 + J143 251 195 + J91 425 + J148 269 185 + J55 487 + J143 250
UR1C2ALW-0714DA35 2/0 1/3 184 + J51 497 + J223 251 191 + J92 470 + J225 271 184 + J55 493 + J222 251
UR1C3ALW-1612DA35 3/0 Full 147 + J49 264 + J51 286 168 + J79 261 + J53 300 149 + J54 263 + J52 285
UR1C3ALW-1714DA35 3/0 2/3 146 + J49 315 + J74 286 162 + J85 309 + J78 303 147 + J53 314 + J74 285
UR1C3ALW-1314DA35 3/0 1/2 146 + J49 357 + J102 286 159 + J87 348 + J106 305 147 + J54 355 + J102 286
UR1C3ALW-0914DA35 3/0 1/3 145 + J49 419 + J162 287 154 + J89 401 + J167 307 146 + J54 413 + J162 286
UR1C4ALW-2012DA35 4/0 Full 116 + J47 209 + J42 328 139 + J72 207 + J43 339 119 + J51 208 + J42 326
UR1C4ALW-2014DA35 4/0 2/3 115 + J47 253 + J58 328 133 + J79 250 + J60 343 117 + J52 252 + J58 327
UR1C4ALW-1614DA35 4/0 1/2 114 + J47 291 + J77 329 129 + J83 285 + J81 346 116 + J52 289 + J77 327
UR1C4ALW-1114DA35 4/0 1/3 114 + J47 351 + J123 329 125 + J86 339 + J128 350 114 + J52 349 + J123 328
UR1C4ALW-0614DA35 4/0 1/6 113 + J47 442 + J261 330 119 + J88 412 + J261 354 113 + J53 438 + J260 329
UR1C5ALX-1314DA35 250 1/3 96 + J46 308 + J100 362 109 + J83 299 + J105 381 97 + J51 306 + J100 361

MEDIUM VOLTAGE
UR1C5ALX-1016DA35 250 1/6 96 + J45 423 + J251 362 102 + J86 394 + J251 388 96 + J51 418 + J250 361
UR1C5ALX-0616DA35 250 1/12 95 + J45 446 + J412 362 99 + J86 402 + J394 391 99 + J86 402 + J394 391

CABLES
UR1C5ALX-1609DA35 350 Full 74 + J44 131 + J31 429 95 + J57 130 + J32 423 77 + J46 131 + J31 421
UR1C5ALX-2212DA35 350 2/3 72 + J44 157 + J37 431 93 + J66 157 + J38 427 75 + J48 159 + J37 427
UR1C5ALX-1712DA35 350 1/2 71 + J44 184 + J45 433 90 + J71 182 + J47 433 74 + J49 183 + J45 429
UR1C5ALX-1814DA35 350 1/3 70 + J44 235 + J68 434 85 + J77 230 + J71 445 72 + J49 234 + J68 431
UR1C5ALX-0914DA35 350 1/6 69 + J44 346 + J165 436 77 + J81 329 + J170 460 70 + J49 343 + J165 435
UR1C5ALX-0716DA35 350 1/12 68 + J44 417 + J367 437 72 + J82 378 + J355 468 69 + J49 412 + J364 436
UR1H0ALX-2010DA35 500 2/3 53 + J41 109 + J29 522 74 + J54 108 + J29 495 56 + J43 109 + J29 505
UR1H0ALX-2412DA35 500 1/2 51 + J42 129 + J33 525 72 + J61 127 + J34 497 54 + J45 128 + J33 511
UR1H0ALX-1612DA35 500 1/3 50 + J42 166 + J45 530 68 + J69 164 + J47 513 52 + J46 166 + J45 522
UR1H0ALX-1314DA35 500 1/6 49 + J42 258 + J96 533 59 + J75 251 + J101 544 50 + J47 257 + J96 530
UR1H0ALX-1016DA35 500 1/12 48 + J42 370 + J245 536 53 + J78 345 + J247 565 48 + J47 366 + J245 534
UR1J0ALY-2310DA35 750 1/2 39 + J38 87 + J25 328 58 + J48 86 + J26 568 42 + J40 87 + J25 592
UR1J0ALY-2412DA35 750 1/3 37 + J39 115 + J31 637 56 + J58 114 + J32 576 40 + J43 115 + J31 610
UR1J0ALY-1914DA35 750 1/6 35 + J40 188 + J58 648 48 + J68 185 + J61 620 37 + J44 188 + J59 638
UR1J0ALY-1014DA35 750 1/12 34 + J40 288 + J136 656 42 + J72 276 + J142 666 35 + J45 286 + J137 651
UR1K0ALY-3010DA35 1000 1/2 32 + J35 66 + J22 718 48 + J40 65 + J22 635 35 + J46 66 + J22 659
UR1K0ALY-2010DA35 1000 1/3 30 + J37 87 + J25 735 48 + J49 86 + J26 633 33 + J40 86 + J25 682
UR1K0ALY-1612DA35 1000 1/6 27 + J38 145 + J42 757 42 + J63 143 + J44 678 30 + J42 144 + J42 727
UR1K0ALY-1314DA35 1000 1/12 26 + J38 236 + J94 772 35 + J68 230 + J99 746 27 + J43 235 + J95 761
UR1M0ALZ-2510DA35 1250 1/3 26 + J36 70 + J22 798 43 + J43 69 + J22 671 30 + J37 69 + J22 720
UR1M0ALZ-2012DA35 1250 1/6 23 + J37 118 + J33 837 39 + J57 116 + J34 708 30 + J42 144 + J42 727
UR1M0ALZ-1614DA35 1250 1/12 21 + J37 199 + J71 863 31 + J65 195 + J74 793 23 + J42 199 + J71 836
UR1P0ALZ-2409DA35 1500 1/3 24 + J34 60 + J20 855 39 + J38 58 + J20 714 27 + J34 59 + J20 759
UR1P0ALZ-2412DA35 1500 1/6 21 + J35 100 + J28 899 37 + J53 99 + J29 734 24 + J39 100 + J28 821
UR1P0ALZ-1914DA35 1500 1/12 19 + J36 174 + J57 934 29 + J62 171 + J60 826 21 + J40 174 + J57 892
1) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, in a trefoil configuration, earth rho of 90°C cm/W, earth ambient of 20°C, neutral wires grounded at both ends,
75% load factor, conductor temperature of 90°C, and 36” depth of burial.
2) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, flat spaced at 7.5” center-to-center spacing, earth rho of 90°C-cm/W, earth ambient of 20°C, neutral wires
grounded at both ends, 75% load factor, conductor temperature of 90°C, and 36” depth of burial.
3) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90°C-cm/ W, earth ambient of 20°C, neutral wires grounded at both
ends, 75% load factor, conductor temperature of 90°C, and 36” depth of burial.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 312
Copyright © 2018, American Wire Group, Inc. 20160110
PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable
LLDPE Jacket UL MV-90/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Item # CONDUCTOR NEUTRAL 10 CYCLES (AMPS) 20 CYCLES (AMPS) 30 CYCLES (AMPS)


AL Size Size Neutral Conductor Capacitance Adiabatic Non Adiabatic Non Adiabatic Non

20°C μΩ/Mft
AWG or or No. Size Resistance (μF/Mft) Adiabatic Adiabatic Adiabatic
kcmil of Wires
CONCENTRIC NEUTRAL CURRENT WITHSTAND
UR1C1ALW-1614DA35 1/0 16X14 Full 0.185 0.043 11570 11868 8304 8602 6432 6730
UR1C1ALW-1114DA35 1/0 11X14 2/3 0.185 0.043 7954 8159 5709 5914 4422 4627
UR1C1ALW-0814DA35 1/0 8X14 1/2 0.185 0.043 5785 5934 4152 4301 3216 3365
UR1C1ALW-0614DA35 1/0 6X14 1/3 0.185 0.043 4339 4451 3114 3226 2412 2524
UR1C2ALW-2014DA35 2/0 20X14 Full 0.143 0.046 14462 14835 10380 10752 8040 8412
UR1C2ALW-1414DA35 2/0 14X14 2/3 0.143 0.046 10123 10385 7266 7527 5628 5888
UR1C2ALW-1014DA35 2/0 10X14 1/2 0.143 0.046 7231 7418 5190 5376 4020 4206
UR1C2ALW-0714DA35 2/0 7X14 1/3 0.143 0.046 5062 5192 3633 3763 2814 2944
UR1C3ALW-1612DA35 3/0 16X12 Full 0.112 0.049 18300 18676 13135 13510 10174 10549
UR1C3ALW-1714DA35 3/0 17X14 2/3 0.112 0.049 12293 12610 8823 9139 6834 7150
UR1C3ALW-1314DA35 3/0 13X14 1/2 0.112 0.049 9400 9643 6747 6989 5226 5468
UR1C3ALW-0914DA35 3/0 9X14 1/3 0.112 0.049 6508 6676 4671 4839 3618 3785
UR1C4ALW-2012DA35 4/0 20X12 Full 0.112 0.053 22875 23345 16418 16887 12717 13186
UR1C4ALW-2114DA35 4/0 21X14 2/3 0.112 0.053 15185 15577 10899 11290 8442 8833
UR1C4ALW-1614DA35 4/0 16X14 1/2 0.112 0.053 11570 11868 8304 8602 6432 6730
UR1C4ALW-1114DA35 4/0 11X14 1/3 0.112 0.053 7954 8159 5709 5914 4422 4627
UR1C4ALW-0614DA35 4/0 6X14 1/6 0.112 0.053 4339 4451 3114 3226 2412 2524
UR1E5ALX-1314DA35 250 13X14 1/3 0.074 0.056 9400 9643 6747 6989 5226 5468
MEDIUM VOLAGE

UR1E5ALX-1016DA35 250 10x16 1/6 0.074 0.056 5179 5327 3251 3398 2518 2665
UR1E5ALX-0616DA35 250 6X16 1/12 0.074 0.056 2717 280 1950 2039 1511 1599
CABLES

UR1F5ALX-1609DA35 350 16X9 Full 0.053 0.062 36369 36900 26104 26634 20220 20749
UR1F5ALX-2212DA35 350 22X12 2/3 0.053 0.062 25162 25679 18060 18576 13989 14504
UR1F5ALX-1712DA35 350 17X12 1/2 0.053 0.062 19444 19843 13955 14354 10810 11208
UR1F5ALX-1814DA35 350 18X14 1/3 0.053 0.062 13016 13352 9342 9677 7236 7571
UR1F5ALX-0914DA35 350 9X14 1/6 0.053 0.062 6508 6676 4671 4839 3618 3785
UR1F5ALX-0716DA35 350 7X16 1/12 0.053 0.062 3625 3729 2275 2378 1763 1865
UR1H0ALX-2010DA35 500 20X10 2/3 0.036 0.071 41754 42349 26207 26800 20300 20892
UR1H0ALX-2412DA35 500 24X12 1/2 0.036 0.071 27450 28013 19702 2026 15261 15823
UR1H0ALX-1612DA35 500 16X12 1/3 0.036 0.071 18300 18676 13135 13510 10174 10549
UR1H0ALX-1314DA35 500 13x14 1/6 0.036 0.071 10750 10992 6747 6989 5226 5468
UR1H0ALX-1016DA35 500 10x16 1/12 0.036 0.071 5179 5327 3251 3398 2518 2665
UR1J5ALY-2310DA35 750 23X10 1/2 0.025 0.082 41990 42673 30138 30820 23345 24026
UR1J5ALY-2412DA35 750 24X12 1/3 0.025 0.082 27450 28013 19702 20265 15261 15823
UR1J5ALY-1914DA35 750 19X14 1/6 0.025 0.082 13739 14093 9861 10215 7638 7991
UR1J5ALY-1014DA35 750 10X14 1/12 0.025 0.082 8269 8456 5190 5376 4020 4206
UR1K0ALY-3010DA35 1000 30X10 1/2 0.018 0.091 62632 63523 39310 40200 30450 31339
UR1K0ALY-2010DA35 1000 20X10 1/3 0.018 0.091 36513 37107 26207 26800 20300 20892
UR1K0ALY-1612DA35 1000 16X12 1/6 0.018 0.091 18300 18676 13135 13510 10174 10549
UR1K0ALY-1314DA35 1000 13X14 1/12 0.018 0.091 10750 10992 6747 6989 5226 5468
UR1M5ALZ-2510DA35 1250 25X10 1/3 0.014 0.099 45641 46384 32759 33500 25375 26115
UR1M5ALZ-2012DA35 1250 20X12 1/6 0.014 0.099 22875 23345 16418 16887 12717 13186
UR1M5ALZ-1614DA35 1250 16X14 1/12 0.014 0.099 13230 13529 8304 8602 6432 6730
UR1P0ALZ-2409DA35 1500 24X9 1/3 0.012 0.107 54554 55350 39156 39950 30330 31124
UR1P0ALZ-2412DA35 1500 24X12 1/6 0.012 0.107 27450 28013 19702 20265 15261 15823
UR1P0ALZ-1914DA35 1500 19X14 1/12 1.012 0.107 15711 16066 9861 10215 7638 7991
1) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, in a trefoil configuration, earth rho of 90°C·cm/W, earth ambient of 20°C, neutral wires grounded at both ends,
75% load factor, conductor temperature of 90°C, and 36” depth of burial.
2) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, flat spaced at 7.5” center-to-center spacing, earth rho of 90°C·cm/W, earth ambient of 20°C, neutral wires
grounded at both ends, 75% load factor, conductor temperature of 90°C, and 36” depth of burial.
3) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90°C·cm/ W, earth ambient of 20°C, neutral wires grounded at both
ends, 75% load factor, conductor temperature of 90°C, and 36” depth of burial..

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
312 Information on this sheet subject to change without notice.
20160110 Copyright © 2018, American Wire Group, Inc.
PowerGuard® 35kV 133% MV 420 Mil TR-XLPE AL Collection System Cable
LLDPE Jacket Concentric Neutral UL MV- 90/AEIC CS8-07
PHYSICAL PROPERTIES

Description
Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation
system consisting of a thermosetting semiconducting conductor shield, high dielectric strength
PowerGuard® TRXLPE insulation, thermosetting semiconducting insulation shield, copper concen-
tric neutral wires, water blocking agents, black encapsulating linear low-density polyethylene
(LLDPE) jacket.
Design Parameters
Conductor: Class B compact stranded aluminum alloy 1350 per ASTM B 231. Stranded conductors
are water-blocked with conductor filling compound.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation.
Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene 420 Mil (TRXLPE) as defined in
ANSI/ICEA S-94-649 - 133% insulation level.
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the
insulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield: Solid bare copper wires helically applied and uniformly spaced.
Water Block: Water-blocking agents applied over the insulation shield and around the neutral wires
to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accor-
dance with the latest edition of ICEA T-34-664 except that the minimum requirements are 15 psig for
1 hour.
Jacket: Black insulating sunlight resistant linear low-density polyethylene encapsulating the neutral
wires with three extruded red stripes and NESC lightning bolt symbol.
Insulation Temperature Rating

MEDIUM VOLTAGE
Normal.............................. 90º C
Emergency*......................130 ºC

CABLES
(*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during
the lifetime of the cable. )
Short Circuit..................... 250º C
Specifications
• ASTM B-231
• AEIC CS8
• ICEA S-94-649
• ICEA T-31-610
• ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable
• UL 1072 MV-90
• CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribu-
tion
Applications
PowerGuard® cables are intended for use in wet or dry locations for distribution of single or three
phase medium-voltage power. These cables may be installed in ducts or direct buried.
Options
Copper Conductors
• Black LLDPE jacket with no stripes
• Multiplex cables
Notes
1. Diameters are based on ASTM Class B Compressed diameters. Sizes 1250 kcmil and 1500 kcmil
are based on ASTM Class A Compressed diameters.
2.Extruded layer thicknesses, insulation and insulation shield diameters are in accordance with
ANSI/ICEA S-94-649 for Concentric Neutral Cables Rated 5-46kV and also meet the requirements
of the latest revisions of AEIC CS8. Dimensions and weights not designated as minimum or maxi-
mum are nominal values and are subject to manufacturing tolerances.
3.Cables buried in flat adjacent configuration with 7.5"" spacing between conductors.
4.Ampacity based on earth thermal resistivity of 90 ºC-cm/watt, 90 ºC conductor temperature, 20 ºC
earth ambient temperature, 75% load factor and 36"" depth of burial. Values are based on one
three-phase circuit, one conductor per phase, with neutral wires bonded at each end.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 318
Copyright © 2018, American Wire Group, Inc. 20160711
PowerGuard® 35kV 133% MV 420 Mil TR-XLPE AL Collection System Cable
LLDPE Jacket Concentric Neutral UL MV- 90/AEIC CS8-07
PHYSICAL PROPERTIES

Item # Conductor Neutral No. ofc Size of Nominal Minimal Maximum Nominal Aluminum Copper Total
Size Size Wires Wires Diameter Insulation Insulation Jacket Conductor Neutral Weight
AWG or (in) Diameter Diameter Diameter (lb/MFT) (lb/MFT) (lb/MFT)
kcmil (2) (in) (in) (in)
(1) (2) (2) (2)
A1/0-01UD35UT100 1/0 Full 16 14 0.362 1.20 1.30 1.56 99 209 1,115
A1/0-01UD35UT203 1/0 2/3 11 14 0.362 1.20 1.30 1.56 99 144 1,026
A1/0-01UD35UT102 1/0 1/2 8 14 0.362 1.20 1.30 1.56 99 104 991
A1/0-01UD35UT103 1/0 1/3 6 14 0.362 1.20 1.30 1.56 99 78 979
A2/0-01UD35UT100 2/0 Full 20 14 0.408 1.24 1.34 1.60 125 266 1,198
A2/0-01UD35UT203 2/0 2/3 14 14 0.408 1.24 1.34 1.60 125 187 1,113
A2/0-01UD35UT102 2/0 1/2 10 14 0.408 1.24 1.34 1.60 125 133 1,055
A2/0-01UD35UT103 2/0 1/3 7 14 0.408 1.24 1.34 1.60 125 93 1,040
A3/0-01UD35UT100 3/0 Full 16 12 0.458 1.29 1.53 1.71 157 332 1,452
A3/0-01UD35UT203 3/0 2/3 17 14 0.458 1.29 1.53 1.65 157 222 1,274
A3/0-01UD35UT102 3/0 1/2 13 14 0.458 1.29 1.53 1.65 157 170 1,160
A3/0-01UD35UT103 3/0 1/3 9 14 0.458 1.29 1.53 1.65 157 118 1,152
A4/0-01UD35UT100 4/0 Full 20 12 0.515 1.35 1.45 1.75 198 415 1,622
A4/0-01UD35UT203 4/0 2/3 21 14 0.515 1.35 1.45 1.73 198 274 1,429
A4/0-01UD35UT102 4/0 1/2 16 14 0.515 1.35 1.45 1.73 198 209 1,374
A4/0-01UD35UT103 4/0 1/3 11 14 0.515 1.35 1.45 1.73 198 144 1,310
A4/0-01UD35UT103 4/0 1/6 6 14 0.515 1.35 1.45 1.73 198 78 1,244
MEDIUM VOLAGE

A250-01UD35UT103 250 1/3 13 14 0.561 1.39 1.49 1.77 234 170 1,415
CABLES

A250-01UD35UT106 250 1/6 10 16 0.561 1.39 1.49 1.75 234 84 1,304


A250-01UD35UT112 250 1/12 6 16 0.561 1.39 1.49 1.75 234 51 1,260
A350-01UD35UT100 350 Full 16 9 0.661 1.50 1.60 2.05 328 667 2,431
A350-01UD35UT203 350 2/3 22 12 0.661 1.50 1.60 1.96 328 458 2,068
A350-01UD35UT102 350 1/2 17 12 0.661 1.50 1.60 1.96 328 354 1,955
A350-01UD35UT103 350 1/3 18 14 0.661 1.50 1.60 1.92 328 235 1,777
A350-01UD35UT106 350 1/6 9 14 0.661 1.50 1.60 1.92 328 117 1,657
A350-01UD35UT112 350 1/12 7 16 0.661 1.50 1.60 1.89 328 59 1,532
A500-01UD35UT203 500 2/3 20 10 0.79 1.63 1.73 2.13 469 662 2,660
A500-01UD35UT102 500 1/2 24 12 0.79 1.63 1.73 2.10 469 498 2,419
A500-01UD35UT103 500 1/3 16 12 0.79 1.63 1.73 2.10 469 332 2,261
A500-01UD35UT106 500 1/6 13 14 0.79 1.63 1.73 2.07 469 170 2,036
A750-01UD35UT102 750 1/2 23 10 0.968 1.82 1.92 2.35 703 761 3,326
A750-01UD35UT103 750 1/3 24 12 0.968 1.82 1.92 2.31 703 498 2,969
A750-01UD35UT103 750 1/6 19 14 0.968 1.82 1.92 2.29 703 248 2,638
A750-01UD35UT112 750 1/12 10 14 0.968 1.82 1.92 2.29 703 133 2,532
A1000-01UD35UT102 1000 1/2 30 10 1.117 1.97 2.07 2.51 937 993 4,038
A1000-01UD35UT103 1000 1/3 20 10 1.117 1.97 2.07 2.51 937 660 3,677
A1000-01UD35UT106 1000 1/6 16 12 1.117 1.97 2.07 2.47 937 332 3,242
A1000-01UD35UT112 1000 1/12 13 14 1.117 1.97 2.07 2.42 937 173 2,994
A1250-01UD35UT103 1250 1/3 25 10 1.25 2.11 2.21 2.80 1,173 827 4,580
A1250-01UD35UT106 1250 1/6 20 12 1.25 2.11 2.21 2.69 1,173 415 3,933
A1250-01UD35UT112 1250 1/12 16 14 1.25 2.11 2.21 2.64 1,173 209 3,640

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
318 Information on this sheet subject to change without notice.
20160711 Copyright © 2018, American Wire Group, Inc.
PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable
XLPE Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Application
PowerGuard®-XL cables are intended for use in wet or dry locations for distribution of single or
three phase medium-voltage power. These cables may be installed in ducts or direct buried.

Construction
Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation
system consisting of a thermosetting semiconducting conductor shield, high dielectric strength
PowerGuard®-XLTRXLPE insulation, thermosetting semiconducting insulation shield, copper con-
centric neutral wires, water blocking agents, black encapsulating cross-linked polyethylene jacket.
Conductor is a Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231.
Stranded conductors are water-blocked with conductor filling compound. Conductor Shield is ex-
truded thermosetting semiconducting shield which is free stripping from the conductor and bonded
to the insulation. Insulation is extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as de-
fined in ANSI/ICEA S-94-649 - 100% insulation level. Insulation Shield is extruded thermosetting
semiconducting shield with controlled adhesion to the insulation providing the required balance be-
tween electrical integrity and ease of stripping. Metallic Shield is solid bare copper wires helically
applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around
the neutral wires to resist longitudinal water penetration. Longitudinal water penetration shall be
tested in accordance with the latest edition of ICEA T-34-664 except that the minimum requirement
is 15 psig for 1 hour. The outer jacket is an extruded-to-fill black non-conducting cross-linked poly-
ethylene jacket, meeting the physical requirements of Table 1 when tested by the methods specified
in ANSI/ICEA S-94-649. The jacket shall be free-stripping and not interfere with an intimate contact
between the neutral wires and the underlying extruded insulation shield. The jacket shall contain a
print legend marking, sequential length marking and three longitudinal extruded red stripes. Fac-
tory Warranty is 20 Years.

MEDIUM VOLTAGE
Options

CABLES
• Copper Conductors
Physical Properties of Extruded-to-Fill XLPE Jacket
• Unaged Tensile Strength, min. (PSI) . . .1500
• Aged* Tensile Strength, min. ret. (%) . . . .70
• Unaged Elongated, min. (%) . . . . . . . . .1500
• Aged* Elongated, min. ret. (%) . . . . . . . . .70
• Heat Distortion 1 hr at 131 ºC, max. (%) . . .3
*Aged for 168 hrs at 121 ºC
Insulation Temperature Rating
Normal . . . . . . . . . . . . . . . . . . . . . . . . . . . .105°C
Emergency* . . . . . . . . . . . . . . . . . . . . . . .140°C
Short Circuit . . . . . . . . . . . . . . . . . . . . . . .350°C
*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during
the lifetime of the cable.

Standards
• ASTM B-231
• AEIC CS8
• ICEA S-94-649
• ICEA T-31-610
• ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable
• UL 1072 MV-105
• CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribu-
tion

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 315
Copyright © 2018, American Wire Group, Inc. 20160216
PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable
XLPE Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Item # CONDUCTOR INSULATION1 CONCENTRIC NEUTRAL JACKET WEIGHTS AMPACITY


AL Size Nominal Minimum Maximum Size No. Size Nominal Aluminum Copper Net DIRECT BURIED
AWG Diameter1 Diameter Diameter of of Diameter Weight Weight Weight Flat2 Tre-Foil3
or kcmil (in) (in) (in) Wires Wires (in) /MFT /MFT /MFT
(lb) (lb) (lb)
PHYSICAL PROPERTIES
A1/0-01UD35GT101X 1/0 0.362 1.045 1.145 Full 12 14 1.409 99 153 946 216 217
A1/0-01UD35GT203X 1/0 0.362 1.045 1.145 2/3 13 16 1.382 99 104 869 217 217
A1/0-01UD35GT102X 1/0 0.362 1.045 1.145 1/2 10 16 1.382 99 80 850 217 217
A1/0-01UD35GT103X 1/0 0.362 1.045 1.145 1/3 7 16 1.382 99 56 831 217 217
A2/0-01UD35GT101X 2/0 0.406 1.090 1.190 Full 15 14 1.453 125 192 1038 250 250
A2/0-01UD35GT203X 2/0 0.406 1.090 1.190 2/3 16 16 1.427 125 129 948 250 250
A2/0-01UD35GT102X 2/0 0.406 1.090 1.190 1/2 12 16 1.427 125 96 923 250 251
A2/0-01UD35GT103X 2/0 0.406 1.090 1.190 1/3 9 16 1.427 125 72 904 251 251
A3/0-01UD35GT101X 3/0 0.456 1.140 1.240 Full 19 14 1.503 157 243 1151 285 266
A3/0-01UD35GT203X 3/0 0.456 1.140 1.240 2/3 13 14 1.503 157 166 1090 285 286
A3/0-01UD35GT102X 3/0 0.456 1.140 1.240 1/2 15 16 1.477 157 120 1013 286 286
A3/0-01UD35GT103X 3/0 0.456 1.140 1.240 1/3 11 16 1.477 157 88 987 286 287
A4/0-01UD35GT101X 4/0 0.512 1.195 1.295 Full 23 14 1.559 199 294 1278 326 328
A4/0-01UD35GT203X 4/0 0.512 1.195 1.295 2/3 15 14 1.559 199 192 1196 327 328
A4/0-01UD35GT102X 4/0 0.512 1.195 1.295 1/2 12 14 1.559 199 153 1166 327 329
A4/0-01UD35GT103X 4/0 0.512 1.195 1.295 1/3 8 14 1.559 199 102 1125 328 329
A250-01UD35GT203X 250 0.558 1.250 1.350 2/3 19 14 1.663 235 243 1404 360 362
MEDIUM VOLAGE

A250-01UD35GT102X 250 0.558 1.250 1.350 1/2 14 14 1.663 235 179 1353 361 362
A250-01UD35GT103X 250 0.558 1.250 1.350 1/3 10 14 1.663 235 128 1312 361 363
CABLES

A250-01UD35GT106X 250 0.558 1.250 1.350 1/6 8 16 1.637 235 64 1216 362 363
A350-01UD35GT203X 350 0.661 1.355 1.455 2/3 16 12 1.803 329 325 1718 427 431
A350-01UD35GT102X 350 0.661 1.355 1.455 1/2 20 14 1.770 329 256 1602 429 433
A350-01UD35GT103X 350 0.661 1.355 1.455 1/3 13 14 1.770 329 166 1530 431 434
A350-01UD35GT106X 350 0.661 1.355 1.455 1/6 11 16 1.743 329 88 1420 435 436
A500-01UD35GT203X 500 0.789 1.480 1.580 2/3 23 12 1.927 469 467 2083 505 522
A500-01UD35GT102X 500 0.789 1.480 1.580 1/2 18 12 1.927 469 366 2001 511 525
A500-01UD35GT103X 500 0.789 1.480 1.580 1/3 12 12 1.927 469 244 1904 522 530
A500-01UD35GT106X 500 0.789 1.480 1.580 1/6 10 14 1.894 469 128 1746 530 533
A750-01UD35GT102X 750 0.968 1.670 1.770 1/2 17 10 2.188 704 549 2709 592 628
A750-01UD35GT103X 750 0.968 1.670 1.770 1/3 18 12 2.146 704 366 2468 610 637
A750-01UD35GT106X 750 0.968 1.670 1.770 1/6 14 14 2.112 704 179 2246 638 648
A750-01UD35GT112X 750 0.968 1.670 1.770 1/12 15 16 2.086 704 120 2142 651 656
A1000-01UD35GT102X 1000 1.117 1.815 1.920 1/2 22 10 2.339 939 711 3226 659 718
A1000-01UD35GT103X 1000 1.117 1.815 1.920 1/3 23 12 2.297 939 467 2931 682 735
A1000-01UD35GT106X 1000 1.117 1.815 1.920 1/6 12 12 2.297 939 244 2752 727 757
A1000-01UD35GT112X 1000 1.117 1.815 1.920 1/12 10 14 2.263 939 128 2581 761 772
A1250-01UD35GT103X 1250 1.250 1.960 2.065 1/3 18 10 2.484 1173 582 3513 720 798
A1250-01UD35GT106X 1250 1.250 1.960 2.065 1/6 15 12 2.442 1173 305 3185 727 837
A1250-01UD35GT112X 1250 1.250 1.960 2.065 1/12 12 14 2.408 1173 153 2952 836 863
A1500-01UD35GT103X 1500 1.370 2.100 2.205 1/3 22 10 2.654 1408 711 4081 759 855
A1500-01UD35GT106X 1500 1.370 2.100 2.205 1/6 18 12 2.612 1408 366 3691 821 899
A1500-01UD35GT112X 1500 1.370 2.100 2.205 1/12 14 14 2.578 1408 179 3454 892 934
1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for concentric neutral cables rated 5-46 kV and also meet the requirements of the latest revisions
of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
2) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90ºC-cm/ W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load fac-
tor, conductor temperature of 105ºC, and 36" depth of burial.
3) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90 ºC-cm/W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load fac-
tor, conductor temperature of 105ºC, and 36" depth of burial.
4) UL Type MV-105 PowerGuard®-XL is rated MV-105 in accordance with the UL 1072 Standard. It should be noted that utilizing a 105 ºC normal operating conductor temperature will increase cable ampacity rating but
will reduce the shield fault capability slightly. If the user plans on operating these cables at 105ºC conductor temperature for normal operation and 140ºC for emergency overload, please contact American Wire Group
for the applicable cable ampacity and shield fault capability ratings. Another important consideration is that the migration of soil moisture away from the cable is more likely at the higher operating conductor tempera-
ture and can result in an increase in soil thermal resistivity, resulting in an increase in conductor and soil temperature.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
315 Information on this sheet subject to change without notice.
20160216 Copyright © 2018, American Wire Group, Inc.
PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable
XLPE Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Item # CONDUCTOR NEUTRAL TREFOIL FLAT SPACED @ 7.5” FLAT SPACED TOUCHING
AL Size Size Pos./Neg. Seq1 Zero Seq1 Ampacity1 Pos./Neg Seq2 Zero Seq2 Ampacity2 Pos./Neg Seq3 Zero Seq3 Ampacity3.
AWG or Impedence Impedence Trefoil Impedence Impedence Flat Impedence Impedence Flat
kcmil (μΩ/ft) (μΩ/ft) (amps) (μΩ/ft) (μΩ/ft) (amps) (μΩ/ft) (μΩ/ft) (amps)
ELECTRICAL PROPERTIES
A1/0-01UD35GT101X 1/0 Full 250 + 53J 477 + 117J 233 261 + 93J 463 + 121J 250 249 + 57J 473 + 117J 233
A1/0-01UD35GT203X 1/0 2/3 249 + 53J 543 + 189J 234 257 + 95J 519 + 192J 251 249 + 58J 538 + 189J 234
A1/0-01UD35GT102X 1/0 1/2 249 + 53J 580 + 258J 234 255 + 95J 547 + 257J 252 248 + 58J 574 + 257J 234
A1/0-01UD35GT103X 1/0 1/3 249 + 53J 605 + 371J 234 252 + 96J 560 + 358J 253 248 + 58J 598 + 369J 234
A2/0-01UD35GT101X 2/0 Full 193 + 50J 386 + 90J 269 208 + 89J 377 + 93J 286 194 + 56J 384 + 90J 269
A2/0-01UD35GT203X 2/0 2/3 193 + 50J 455 + 147J 269 203 + 91J 437 + 151J 288 193 + 55J 451 + 147J 269
A2/0-01UD35GT102X 2/0 1/2 193 + 50J 501 + 211J 270 200 + 92J 475 + 213J 290 192 + 55J 497 + 210J 270
A2/0-01UD35GT103X 2/0 1/3 192 + 50J 535 + 294J 270 197 + 93J 499 + 289J 292 192 + 56J 530 + 292J 270
A3/0-01UD35GT101X 3/0 Full 153 + 49J 311 + 68J 307 170 + 84J 305 + 71J 323 154 + 54J 309 + 68J 307
A3/0-01UD35GT203X 3/0 2/3 152 + 49J 369 + 106J 308 165 + 87J 358 + 110J 327 153 + 54J 366 + 106J 307
A3/0-01UD35GT102X 3/0 1/2 152 + 49J 425 + 159J 308 161 + 89J 406 + 163J 329 152 + 54J 421 + 159J 308
A3/0-01UD35GT103X 3/0 1/3 152 + 49J 472 + 234J 308 158 + 90J 443 + 234J 331 145 + 54J 456 + 224J 308
A4/0-01UD35GT101X 4/0 Full 120 + 47J 252 + 55J 352 139 + 78J 248 + 57J 366 122 + 52J 250 + 55J 351
A4/0-01UD35GT203X 4/0 2/3 119 + 47J 311 + 86J 353 133 + 84J 303 + 90J 369 120 + 52J 309 + 86J 352
A4/0-01UD35GT102X 4/0 1/2 119 + 47J 347 + 114J 353 130 + 85J 336 + 118J 373 120 + 52J 345 + 114J 353
A4/0-01UD35GT103X 4/0 1/3 119 + 47J 414 + 192J 354 126 + 87J 392 + 195J 377 119 + 52J 410 + 192J 354
A250-01UD35GT203X 250 2/3 102 + 46J 260 + 66J 354 118 + 80J 255 + 69J 382 103 + 50J 259 + 66J 355
A250-01UD35GT102X 250 1/2 101 + 46J 307 + 95J 389 113 + 82J 297 + 99J 411 102 + 51J 304 + 95J 388

MEDIUM VOLTAGE
A250-01UD35GT103X 250 1/3 101 + 46J 362 + 147J 389 110 + 84J 346 + 151J 418 101 + 51J 359 + 146J 389
A250-01UD35GT106X 250 1/6 100 + 45J 448 + 329J 389 104 + 86J 410 + 321J 421 100 + 51J 442 + 327J 390

CABLES
A350-01UD35GT203X 350 2/3 74 + 44J 196 + 48J 463 92 + 73J 193 + 51J 466 76 + 49J 194 + 49J 459
A350-01UD35GT102X 350 1/2 73 + 44J 225 + 61J 465 89 + 76J 221 + 64J 472 75 + 49J 224 + 61J 462
A350-01UD35GT103X 350 1/3 73 + 44J 291 + 104J 466 84 + 80J 281 + 108J 481 74 + 49J 289 + 104J 464
A350-01UD35GT106X 350 1/6 72 + 44J 390 + 233J 469 78 + 82J 364 + 234J 496 72 + 50J 386 + 232J 468
A500-01UD35GT203X 500 2/3 53 + 41J 137 + 34J 561 74 + 62J 136 + 35J 546 56 + 45J 137 + 34J 552
A500-01UD35GT102X 500 1/2 53 + 42J 160 + 41J 564 71 + 67J 159 + 43J 550 55 + 46J 159 + 41J 556
A500-01UD35GT103X 500 1/3 51 + 42J 209 + 63J 569 66 + 73J 205 + 66J 564 53 + 47J 239 + 90J 563
A500-01UD35GT106X 500 1/6 50 + 42J 310 + 143J 573 59 + 77J 296 + 147J 589 51 + 47J 307 + 142J 571
A750-01UD35GT102X 750 1/2 39 + 39J 110 + 30J 674 58 + 56J 109 + 30J 633 42 + 42J 110 + 30J 659
A750-01UD35GT103X 750 1/3 37 + 40J 146 + 40J 685 54 + 64J 145 + 41J 642 40 + 44J 145 + 40J 671
A750-01UD35GT106X 750 1/6 36 + 40J 240 + 90J 698 46 + 71J 234 + 95J 685 37 + 45J 239 + 90J 689
A750-01UD35GT112X 750 1/12 35 + 40J 306 + 154J 705 42 + 73J 292 + 159J 722 36 + 45J 303 + 154J 702
A1000-01UD35GT102X 1000 1/2 31 + 37J 84 + 25J 770 50 + 48J 84 + 25J 711 35 + 39J 84 + 25J 748
A1000-01UD35GT103X 1000 1/3 29 + 37J 114 + 31J 790 47 + 57J 113 + 32J 712 32 + 42J 114 + 31J 766
A1000-01UD35GT106X 1000 1/6 27 + 38J 186 + 61J 815 39 + 66J 183 + 64J 759 29 + 43J 185 + 61J 797
A1000-01UD35GT112X 1000 1/12 26 + 38J 286 + 142J 831 33 + 69J 274 + 147J 823 27 + 43J 283 + 142J 821
A1250-01UD35GT103X 1250 1/3 25 + 37J 92 + 26J 857 42 + 52J 92 + 27J 759 29 + 40J 92 + 27J 823
A1250-01UD35GT106X 1250 1/6 23 + 37J 152 + 46J 901 36 + 62J 151 + 48J 801 25 + 42J 153 + 46J 797
A1250-01UD35GT112X 1250 1/12 22 + 37J 251 + 111J 930 29 + 66J 243 + 116J 886 23 + 42J 249 + 111J 912
A1500-01UD35GT103X 1500 1/3 23 + 35J 78 + 23J 918 40 + 46J 77 + 24J 809 27 + 38J 78 + 23J 876
A1500-01UD35GT106X 1500 1/6 20 + 36J 131 + 38J 969 34 + 58J 130 + 39J 836 23 + 40J 131 + 38J 931
A1500-01UD35GT112X 1500 1/12 19 + 36J 226 + 91J 1008 27 + 64J 220 + 95J 931 20 + 40J 224 + 91J 982
1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for concentric neutral cables rated 5-46 kV and also meet the requirements of the latest revisions
of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
2) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90ºC-cm/ W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load fac-
tor, conductor temperature of 105ºC, and 36" depth of burial.
3) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90 ºC-cm/W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load fac-
tor, conductor temperature of 105ºC, and 36" depth of burial.
4) UL Type MV-105 PowerGuard®-XL is rated MV-105 in accordance with the UL 1072 Standard. It should be noted that utilizing a 105 ºC normal operating conductor temperature will increase cable ampacity rating but
will reduce the shield fault capability slightly. If the user plans on operating these cables at 105ºC conductor temperature for normal operation and 140ºC for emergency overload, please contact American Wire Group
for the applicable cable ampacity and shield fault capability ratings. Another important consideration is that the migration of soil moisture away from the cable is more likely at the higher operating conductor tempera-
ture and can result in an increase in soil thermal resistivity, resulting in an increase in conductor and soil temperature.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 315
Copyright © 2018, American Wire Group, Inc. 20160216
PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable
XLPE Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Item # Conductor Neutral Conductor Capacitance 10 CYCLES (AMPS) 20 CYCLES (AMPS) 30 CYCLES (AMPS)

20°C μΩ/Mft
AL Size Size Resistance (μF/Mft) Adiabatic Non Adiabatic Non Adiabatic Non
AWG or Adiabatic Adiabatic Adiabatic
kcmil
CURRENT WITHSTAND
A1/0-01UD35GT101X 1/0 Full 0.1850 0.0430 8173 8384 5866 6077 4544 4754
A1/0-01UD35GT203X 1/0 2/3 0.1850 0.0430 5540 5720 3976 4156 3080 3260
A1/0-01UD35GT102X 1/0 1/2 0.1850 0.0430 4261 4400 3059 3197 2369 2507
A1/0-01UD35GT103X 1/0 1/3 0.1850 0.0430 2983 3080 2141 2238 1658 1755
A2/0-01UD35GT101X 2/0 Full 0.1430 0.0465 10217 10480 7333 7596 5680 5943
A2/0-01UD35GT203X 2/0 2/3 0.1430 0.0465 6818 7040 4894 5115 3791 4012
A2/0-01UD35GT102X 2/0 1/2 0.1430 0.0465 5114 5280 3670 3837 2843 3009
A2/0-01UD35GT103X 2/0 1/3 0.1430 0.0465 3835 3960 2753 2877 2132 2257
A3/0-01UD35GT101X 3/0 Full 0.1130 0.0494 12892 13225 9253 9586 7167 7499
A3/0-01UD35GT203X 3/0 2/3 0.1130 0.0494 8855 9083 6355 6583 4923 5150
A3/0-01UD35GT102X 3/0 1/2 0.1130 0.0494 6392 6600 4588 4796 3554 3761
A3/0-01UD35GT103X 3/0 1/3 0.1130 0.0494 4688 4840 3364 3517 2606 2758
A4/0-01UD35GT101X 4/0 Full 0.0880 0.0531 15606 16010 11201 11604 8676 9078
A4/0-01UD35GT203X 4/0 2/3 0.0880 0.0531 10217 10480 7333 7596 5680 5943
A4/0-01UD35GT102X 4/0 1/2 0.0880 0.0531 8173 8384 5866 6077 4544 4754
A4/0-01UD35GT103X 4/0 1/3 0.0880 0.0531 5617 5757 3911 4051 3029 3169
A250-01UD35GT203X 250 2/3 0.0740 0.0560 13289 13622 9253 9586 7167 7499
A250-01UD35GT102X 250 1/2 0.0740 0.0560 9499 9745 6818 7063 5281 5526
MEDIUM VOLAGE

A250-01UD35GT103X 250 1/3 0.0740 0.0560 6811 6987 4889 5064 3787 3962
A250-01UD35GT106X 250 1/6 0.0740 0.0560 3413 3524 2450 2560 1897 2008
CABLES

A350-01UD35GT203X 350 2/3 0.0530 0.0624 17237 17591 12372 12725 9583 9936
A350-01UD35GT102X 350 1/2 0.0530 0.0624 13571 13921 9740 10090 7545 7894
A350-01UD35GT103X 350 1/3 0.0530 0.0624 9127 9356 6355 6583 4923 5150
A350-01UD35GT106X 350 1/6 0.0530 0.0624 4688 4840 3364 3517 2606 2758
A500-01UD35GT203X 500 2/3 0.0360 0.0706 24798 25307 17799 18307 13787 14294
A500-01UD35GT102X 500 1/2 0.0360 0.0706 19392 19790 13919 14316 10781 11178
A500-01UD35GT103X 500 1/3 0.0360 0.0706 12928 13194 9279 9544 7188 7452
A500-01UD35GT106X 500 1/6 0.0360 0.0706 6811 6987 4889 5064 3787 3962
A750-01UD35GT102X 750 1/2 0.0250 0.0818 29234 29710 20983 21458 16253 16728
A750-01UD35GT103X 750 1/3 0.0250 0.0818 19392 19790 13919 14316 10781 11178
A750-01UD35GT106X 750 1/6 0.0250 0.0818 9536 9782 6844 7090 5301 5547
A750-01UD35GT112X 750 1/12 0.0250 0.0818 6392 6600 4588 4796 3554 3761
A1000-01UD35GT102X 1000 1/2 0.0180 0.0912 37833 38448 27154 27769 21033 21647
A1000-01UD35GT103X 1000 1/3 0.0180 0.0912 24798 25307 17799 18307 13787 14294
A1000-01UD35GT106X 1000 1/6 0.0180 0.0912 12928 13194 9279 9544 7188 7452
A1000-01UD35GT112X 1000 1/12 0.0180 0.0912 6811 6987 4889 5064 3787 3962
A1250-01UD35GT103X 1250 1/3 0.0140 0.0995 31907 32410 22217 22720 17209 17712
A1250-01UD35GT106X 1250 1/6 0.0140 0.0995 16160 16492 11599 11930 8984 9315
A1250-01UD35GT112X 1250 1/12 0.0140 0.0995 8173 8384 5866 6077 4544 4754
A1500-01UD35GT103X 1500 1/3 0.0120 0.1069 38883 39497 27074 27688 20972 21585
A1500-01UD35GT106X 1500 1/6 0.0120 0.1069 19392 19790 13919 14316 10781 11178
A1500-01UD35GT112X 1500 1/12 0.0120 0.1069 9829 10075 6844 7090 5301 5547
1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for concentric neutral cables rated 5-46 kV and also meet the requirements of the latest revisions
of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
2) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90ºC-cm/ W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load fac-
tor, conductor temperature of 105ºC, and 36" depth of burial.
3) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90 ºC-cm/W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load fac-
tor, conductor temperature of 105ºC, and 36" depth of burial.
4) UL Type MV-105 PowerGuard®-XL is rated MV-105 in accordance with the UL 1072 Standard. It should be noted that utilizing a 105 ºC normal operating conductor temperature will increase cable ampacity rating but
will reduce the shield fault capability slightly. If the user plans on operating these cables at 105ºC conductor temperature for normal operation and 140ºC for emergency overload, please contact American Wire Group
for the applicable cable ampacity and shield fault capability ratings. Another important consideration is that the migration of soil moisture away from the cable is more likely at the higher operating conductor tempera-
ture and can result in an increase in soil thermal resistivity, resulting in an increase in conductor and soil temperature.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
315 Information on this sheet subject to change without notice.
2010216 Copyright © 2018, American Wire Group, Inc.
PowerGuard® 15kV 133% MV TR-XLPE Aluminum Collection System Cable
XLPE Jacket UL MV-105/AEIC CS8-07

Applications
PowerGuard® XL cables are intended for use in wet or dry locations for distribution of single or
three phase medium-voltage power. These cables may be installed in ducts or direct buried.

Description
Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation
system consisting of a thermosetting semiconducting conductor shield, high dielectric strength
PowerGuard XLTRXLPE insulation, thermosetting semiconducting insulation shield, copper concen-
tric neutral wires, water blocking agents, black encapsulating cross-linked polyethylene jacket.

Construction
Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231.
Stranded conductors are water-blocked with conductor filling compound.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation.
Insulation: Extruded, unfilled Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in
ANSI/ICEA S-94-649 - 133% insulation level.
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the in-
sulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield: Solid bare copper wires helically applied and uniformly spaced.
Water Block: Water-blocking agents applied over the insulation shield and around the neutral wires
to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accor-
dance with the latest edition of ICEA T-34-664 except that the minimum requirement is 15 psig for 1
hour.

MEDIUM VOLTAGE
Jacket: The outer jacket is an extruded-to-fill black non-conducting cross-linked polyethylene jacket,
meeting the physical requirements of Table 1 when tested by the methods specified in ANSI/ICEA S-

CABLES
94-649. The jacket shall be free-stripping and not interfere with an intimate contact between the neu-
tral wires and the underlying extruded insulation shield. The jacket shall contain a print legend
marking, sequential length marking and three longitudinal extruded red stripes.
Factory Warranty: 20 Years

Physical Properties of Extruded-to-Fill XLPE Jacket


Unaged Tensile Strength, min. (PSI) 1500
Aged* Tensile Strength, min. ret. (%) 70
Unaged Elongated, min. (%) 1500
Aged* Elongated, min. ret. (%) 70
Heat Distortion 1 hr at 131°C, max. (%) 30
*Aged for 168 hrs at 121°C

Insulation Temperature Rating


Normal 105°C
Emergency* 140°C
Short Circuit 250°C
* Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of
the cable.

Specifications
• ASTM B-231
• AEIC CS8
• ICEA S-94-649
• ICEA T-31-610
• ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable
• UL-1072 MV-105

Options
• Copper Conductors

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 320
Copyright © 2018, American Wire Group, Inc. 20161021
PowerGuard® 15kV 133% MV TR-XLPE Aluminum Collection System Cable
XLPE Jacket UL MV-105/AEIC CS8-07

Item # Conductor Neutral Neutral Neutral TRXLPE TRXLPE TRXLPE1 Encap XLPE Encap XLPE Aprox Weight Ampacity Direct Buried
Size No. of Nominal Size No. of Size Insulation1 Insulation1 Insulation Jacket1 Jacket1 Conductor Neutral Net Flat2 Tre-Foil3
AWG/ Wires Diameter AWG/ Wires Nominal Minimum Maximum Nominal Nominal (lbs/MFT) (lbs/MFT) (lbs/MFT)
kcmil (in) kcmil (mil) Thickness Diameter Diameter Thickness Diameter
(mil) (in) (in) (mil) (in)
A1/0-01UD15UT100X 1/0 19 0.362 14 12 Full 0.220 0.805 0.895 0.055 1.159 99 153 718 216 217
A1/0-01UD15UT203X 1/0 19 0.362 16 13 2/3 0.220 0.805 0.895 0.055 1.132 99 104 647 217 217
A1/0-01UD15UT102X 1/0 19 0.362 16 10 1/2 0.220 0.805 0.895 0.055 1.132 99 80 628 217 217
A1/0-01UD15UT103X 1/0 19 0.362 16 7 1/3 0.220 0.805 0.895 0.055 1.132 99 56 609 217 217
A2/0-01UD15UT100X 2/0 19 0.406 14 15 Full 0.220 0.850 0.940 0.055 1.203 125 192 803 250 250
A2/0-01UD15UT203X 2/0 19 0.406 16 16 2/3 0.220 0.850 0.940 0.055 1.177 125 129 720 250 250
A2/0-01UD15UT102X 2/0 19 0.406 16 12 1/2 0.220 0.850 0.940 0.055 1.177 125 96 694 250 251
A2/0-01UD15UT103X 2/0 19 0.406 16 9 1/3 0.220 0.850 0.940 0.055 1.177 125 72 675 251 251
A3/0-01UD15UT100X 3/0 19 0.456 14 19 Full 0.220 0.900 0.990 0.055 1.253 157 243 908 285 286
A3/0-01UD15UT203X 3/0 19 0.456 14 13 2/3 0.220 0.900 0.990 0.055 1.253 157 166 846 285 286
A3/0-01UD15UT102X 3/0 19 0.456 16 15 1/2 0.220 0.900 0.990 0.055 1.227 157 120 776 286 286
A3/0-01UD15UT103X 3/0 19 0.456 16 11 1/3 0.220 0.900 0.990 0.055 1.227 157 88 750 286 287
A4/0-01UD15UT100X 4/0 19 0.512 14 23 Full 0.220 0.955 1.045 0.055 1.309 199 294 1026 326 328
A4/0-01UD15UT203X 4/0 19 0.512 14 15 2/3 0.220 0.955 1.045 0.055 1.309 199 192 944 327 328
A4/0-01UD15UT102X 4/0 19 0.512 14 12 1/2 0.220 0.955 1.045 0.055 1.309 199 153 914 327 329
A4/0-01UD15UT103X 4/0 19 0.512 14 8 1/3 0.220 0.955 1.045 0.055 1.309 199 102 873 328 329
MEDIUM VOLAGE

A250-01UD15UT203X 250 37 0.558 14 19 2/3 0.220 1.010 1.100 0.080 1.413 235 243 1131 360 362
CABLES

A250-01UD15UT102X 250 37 0.558 14 14 1/2 0.220 1.010 1.100 0.080 1.413 235 179 1080 361 362
A250-01UD15UT103X 250 37 0.558 14 10 1/3 0.220 1.010 1.100 0.080 1.413 235 128 1039 361 363
A250-01UD15UT106X 250 37 0.558 16 8 1/6 0.220 1.010 1.100 0.080 1.387 235 64 950 362 363
A350-01UD15UT203X 350 37 0.661 12 16 2/3 0.220 1.115 1.205 0.080 1.553 329 325 1420 427 431
A350-01UD15UT102X 350 37 0.661 14 20 1/2 0.220 1.115 1.205 0.080 1.520 329 256 1312 429 433
A350-01UD15UT103X 350 37 0.661 14 13 1/3 0.220 1.115 1.205 0.080 1.520 329 166 1240 431 434
A350-01UD15UT106X 350 37 0.661 16 11 1/6 0.220 1.115 1.205 0.080 1.493 329 88 1137 435 436
A500-01UD15UT203X 500 37 0.789 12 23 2/3 0.220 1.240 1.330 0.080 1.677 469 467 1765 505 522
A500-01UD15UT102X 500 37 0.789 12 18 1/2 0.220 1.240 1.330 0.080 1.677 469 366 1684 511 525
A500-01UD15UT103X 500 37 0.789 12 12 1/3 0.220 1.240 1.330 0.080 1.677 469 244 1586 522 530
A500-01UD15UT106X 500 37 0.789 14 10 1/6 0.220 1.240 1.330 0.080 1.644 469 128 1437 530 533
A750-01UD15UT102X 750 61 0.968 10 17 1/2 0.220 1.430 1.520 0.080 1.938 704 549 2344 592 628
A750-01UD15UT103X 750 61 0.968 12 18 1/3 0.220 1.430 1.520 0.080 1.896 704 366 2115 610 637
A750-01UD15UT106X 750 61 0.968 14 14 1/6 0.220 1.430 1.520 0.080 1.862 704 179 1901 638 648
A750-01UD15UT112X 750 61 0.968 16 15 1/12 0.220 1.430 1.520 0.080 1.836 704 120 1804 651 656
A1000-01UD15UT102X 1000 61 1.117 10 22 1/2 0.220 1.575 1.670 0.080 2.089 939 711 2838 659 718
A1000-01UD15UT103X 1000 61 1.117 12 23 1/3 0.220 1.575 1.670 0.080 2.047 939 467 2554 682 735
A1000-01UD15UT106X 1000 61 1.117 12 12 1/6 0.220 1.575 1.670 0.080 2.047 939 244 2375 727 757
A1000-01UD15UT112X 1000 61 1.117 14 10 1/12 0.220 1.575 1.670 0.080 2.013 939 128 2213 761 772
A1250-01UD15UT103X 1250 61 1.25 10 18 1/3 0.220 1.720 1.815 0.080 2.234 1173 582 3102 720 798
A1250-01UD15UT106X 1250 61 1.25 12 15 1/6 0.220 1.720 1.815 0.080 2.192 1173 305 2786 727 837
A1250-01UD15UT112X 1250 61 1.25 14 12 1/12 0.220 1.720 1.815 0.080 2.158 1173 153 2590 836 863
1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for concentric neutral cables rated 5-46 kV and also meet the requirements of the latest revisions
of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
2) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90ºC-cm/ W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load fac-
tor, conductor temperature of 105ºC, and 36" depth of burial.
3) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90 ºC-cm/W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load fac-
tor, conductor temperature of 105ºC, and 36" depth of burial.
4) UL Type MV-105 PowerGuard®-XL is rated MV-105 in accordance with the UL 1072 Standard. It should be noted that utilizing a 105 ºC normal operating conductor temperature will increase cable ampacity rating but
will reduce the shield fault capability slightly. If the user plans on operating these cables at 105ºC conductor temperature for normal operation and 140ºC for emergency overload, please contact Classic Wire and
Cable, LLC for the applicable cable ampacity and shield fault capability ratings. Another important consideration is that the migration of soil moisture away from the cable is more likely at the higher operating conduc-
tor temperature and can result in an increase in soil thermal resistivity, resulting in an increase in conductor and soil temperature.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
320 Information on this sheet subject to change without notice.
20161021 Copyright © 2018, American Wire Group, Inc.
PowerGuard® 5kV-35kV Aluminum TR-XLPE Tape Shield
PVC Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Applications
PowerGuard cables are intended for use in wet or dry locations for distribution of single or three
phase medium-voltage power. These cables may be installed in ducts or direct buried.

Construction
Cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield
are extruded over an aluminum conductor and cured in a single operation. Uncoated copper tape
(helically applied) and overlaying black PVC jacket are applied over the cable core. The conductor
Class B compressed concentric lay, filled stranded 1350 aluminum. Conductor shield is an extruded
semi-conducting thermosetting polymeric stress control layer. Insulation is extruded, TRXLPE (Tree-
Retardant Cross-linked Polyethylene). Insulation shield is an extruded semi-conducting thermoset-
ting layer, clean and free-stripping from insulation. The metallic shield is flat uncoated 5-mil-thick
copper tape helically applied with minimum 25% overlap. The jacket is sunlight and moisture resist-
ant black, non-conducting PVC (Polyvinyl Chloride).

Features
• Triple-extruded for clean interfaces
• Dry nitrogen cure for enhanced performance
• Class 10,000 environment utilized for material handling
• Excellent moisture resistance
• High dielectric strength
• Low dielectric loss
• Excellent resistance to treeing
• Clean-stripping insulation shield
• Sunlight and moisture resistant
• Approved for CT use 1/0 and larger

MEDIUM VOLTAGE
Standards

CABLES
• ANSI/ICEA S-97-682
• UL-1072 MV-105
• AEIC CS8 as applicable for TRXLPE (Tree-Retardant Cross-linked Polyethylene) insulated shielded
power cable
• ICEA T-31-610
• CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribu-
tion
Temperature Rating
Normal..............................105°C
Emergency*.................... 140°C
Short Circuit.................... 250°C
*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during
the lifetime of the cable.

Options
• Copper conductors
• CPE (chlorinated polyethylene) Jacket conforming to the requirements specified for chlorinated
polyethylene jackets in ICEA. The average thickness shall be in accordance with Table 4-3 of ICEA
and the minimum spot thickness shall be not less than 80% of the average thickness
• Non-filled conductor
• Compact strand conductor

For information on conductor sizes or voltage ratings not shown in the tables, contact your AWG
sales representative or email: sales@buyawg.com.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 314
Copyright © 2018, American Wire Group, Inc. 20160110
PowerGuard® 5kV-35kV Aluminum TR-XLPE Tape Shield
PVC Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Item # Compressed Nominal Diameter Diameter Diameter Diameter Nominal Approx. Approx. Approx. Ampacity2 Ampacity2
Conductor Insulation Insulation Insulation 5 mil CU PVC Jacket Weight Weight Weight Direct in Duct
Aluminum Thickness Min Max Tape Jacket Thickness AL CU Total Buried
Size/No of Wires (mil) (in)1 (in)1 (in)1 (in)1 (in)1 (lb/Mft)1 (lb/Mft)1 (lb/Mft)1
115 Mils TRXLPE 5kV 133% OR 8kV 100%
A2-01MV5UT10501 2/7 115 0.525 0.605 0.621 0.75 0.065 62 44 289 165 125
A1/0-01MV5UT10501 1/0 / 19 115 0.605 0.685 0.7 0.829 0.065 99 49 357 215 165
A2/0-01MV5UT10501 2/0 / 19 115 0.65 0.725 0.744 0.903 0.08 125 53 426 245 185
A3/0-01MV5UT10501 3/0 / 19 115 0.7 0.775 0.794 0.953 0.08 158 56 482 280 210
A4/0-01MV5UT10501 4/0 / 19 115 0.755 0.835 0.85 1.009 0.08 199 60 549 320 240
A250-01MV5UT10501 250 / 37 115 0.81 0.89 0.906 1.065 0.08 234 64 640 350 275
A350-01MV5UT10501 350 / 37 115 0.905 0.98 1.009 1.168 0.08 329 71 754 425 330
A500-01MV5UT10501 500 / 37 115 1.04 1.12 1.137 1.296 0.08 468 81 954 520 405
A750-01MV5UT10501 750 / 61 115 1.23 1.31 1.324 1.483 0.08 703 94 1279 655 510
A1000-01MV5UT10501 1000 / 61 115 1.375 1.46 1.473 1.632 0.08 937 104 1584 760 610
175 Mils TRXLPE 15kV 100%
A2-01MV15GT10501 2/7 175 0.635 0.72 0.741 0.87 0.08 62 52 364 165 125
A1-01MV15GT10501 1 / 19 175 0.675 0.76 0.78 0.939 0.08 78 55 422 190 145
A1/0-01MV15GT10501 1/0 / 19 175 0.715 0.8 0.82 0.979 0.08 99 58 463 215 165
A2/0-01MV15GT10501 2/0 / 19 175 0.76 0.845 0.864 1.023 0.08 125 61 513 245 185
A3/0-01MV15GT10501 3/0 / 19 175 0.81 0.895 0.914 1.073 0.08 158 65 572 280 210
MEDIUM VOLAGE

A4/0-01MV15GT10501 4/0 / 19 175 0.865 0.95 0.97 1.129 0.08 199 69 643 320 240
CABLES

A250-01MV15GT10501 250 / 37 175 0.92 1.005 1.026 1.185 0.08 234 73 710 350 275
A350-01MV15GT10501 350 / 37 175 1.015 1.1 1.129 1.288 0.08 329 80 861 425 330
A500-01MV15GT10501 500 / 37 175 1.15 1.235 1.257 1.416 0.08 468 89 1070 520 405
A750-01MV15GT10501 750 / 61 175 1.34 1.425 1.444 1.603 0.08 703 102 1410 655 510
A1000-01MV15GT1051 1000 / 61 175 1.485 1.575 1.593 1.812 0.11 937 113 1822 760 610
220 Mils TRXLPE 15kV 133%
A2-01MV15UT10501 2/7 220 0.725 0.815 0.831 0.99 0.08 62 59 451 165 125
A1-01MV15UT10501 1 / 19 220 0.765 0.855 0.87 1.029 0.08 78 62 488 190 145
A1/0-01MV15UT10501 1/0 / 19 220 0.805 0.895 0.91 1.069 0.08 99 64 532 215 165
A2/0-01MV15UT10501 2/0 / 19 220 0.85 0.935 0.954 1.113 0.08 125 68 584 245 185
A3/0-01MV15UT10501 3/0 / 19 220 0.9 0.985 1.004 1.163 0.08 158 71 646 280 210
A4/0-01MV15UT10501 4/0 / 19 220 0.955 1.045 1.06 1.219 0.08 199 75 720 320 240
A250-01MV15UT10501 250 / 37 220 1.01 1.1 1.116 1.275 0.08 234 79 790 350 275
A350-01MV15UT10501 350 / 37 220 1.105 1.19 1.219 1.378 0.08 329 86 947 425 330
A500-01MV15UT10501 500 / 37 220 1.24 1.33 1.347 1.506 0.08 468 96 1163 520 405
A750-01MV15UT10501 750 / 61 220 1.43 1.52 1.534 1.693 0.08 703 109 1513 650 510
A1000-01MV15UT1051 1000 / 61 220 1.575 1.67 1.683 1.902 0.11 937 119 1939 760 610
(1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-97-682 for shielded power cables rated 5-46
kV and also meet the requirements of the latest revisions of AEIC CS8.
(2) Ampacity based on earth thermal resistivity of 90˚C-cm/watt, 105˚C conductor temp., 20˚C earth ambient temperature, 75% load factor and 36" depth of bur-
ial. Values are based on one three-phase circuit, one conductor per phase, in flat adjacent configuration (direct buried) with metallic shield bonded at each
end.
Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means
mass.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
314 Information on this sheet subject to change without notice.
20160110 Copyright © 2018, American Wire Group, Inc.
PowerGuard® 5kV-35kV Aluminum TR-XLPE Tape Shield
PVC Jacket UL MV-105/AEIC CS8-07
Manufactured by Seoul Electric Cable Co., Ltd

Item # Compressed Nominal Diameter Diameter Diameter Diameter Nominal Approx. Approx. Approx. Ampacity2 Ampacity2
Conductor Insulation Insulation Insulation 5 mil CU PVC Jacket Weight Weight Weight Direct in Duct
Aluminum Thickness Min Max Tape Jacket Thickness AL CU Total Buried
Size/No of Wires (mil) (in)1 (in)1 (in)1 (in)1 (in)1 (lb/Mft)1 (lb/Mft)1 (lb/Mft)1
260 Mils TRXLPE 25kV 100%
A1-01MV25GT10501 1 / 19 260 0.835 0.925 0.95 1.109 0.08 78 67 551 185 145
A1/0-01MV25GT10501 1/0 / 19 260 0.875 0.965 0.99 1.149 0.08 99 70 597 215 165
A2/0-01MV25GT10501 2/0 / 19 260 0.92 1.01 1.034 1.193 0.08 125 73 651 245 185
A3/0-01MV25GT10501 3/0 / 19 260 0.97 1.06 1.084 1.243 0.08 158 77 716 275 215
A4/0-01MV25GT10501 4/0 / 19 260 1.025 1.115 1.14 1.299 0.08 199 81 793 315 250
A250-01MV25GT10501 250 / 37 260 1.08 1.175 1.196 1.355 0.08 234 85 866 350 275
A350-01MV25GT10501 350 / 37 260 1.175 1.265 1.299 1.458 0.08 329 92 1027 420 335
A500-01MV25GT10501 500 / 37 260 1.31 1.405 1.427 1.586 0.08 468 101 1250 515 405
A750-01MV25GT10501 750 / 61 260 1.5 1.595 1.614 1.833 0.11 703 115 1707 650 520
A1000-01MV25GT1051 1000 / 61 260 1.645 1.74 1.763 1.982 0.11 937 125 2047 755 605
345 Mils TRXLPE 35kV 100%
A1/0-01MV35GT10501 1/0 / 19 345 1.045 1.145 1.16 1.319 0.08 99 82 748 210 170
A2/0-01MV35GT10501 2/0 / 19 345 1.09 1.119 1.204 1.363 0.08 125 85 807 240 190
A3/0-01MV35GT10501 3/0 / 19 345 1.14 1.24 1.254 1.413 0.08 158 89 877 275 220
A4/0-01MV35GT10501 4/0 / 19 345 1.195 1.295 1.31 1.469 0.08 199 93 960 310 250
A250-01MV35GT10501 250 / 37 345 1.25 1.35 1.366 1.525 0.08 234 97 1039 345 275

MEDIUM VOLTAGE
A350-01MV35GT10501 350 / 37 345 1.345 1.445 1.469 1.628 0.08 329 104 1212 415 340
A500-01MV35GT10501 500 / 37 345 1.48 1.58 1.597 1.816 0.11 468 113 1544 510 410

CABLES
A750-01MV35GT10501 750 / 61 345 1.67 1.77 1.784 2.003 0.11 703 127 1934 640 525
A1000-01MV35GT1051 1000 / 61 345 1.815 1.92 1.933 2.152 0.11 937 137 2290 745 615
420 Mils TRXLPE 35kV 133%
A1/0-01MV35UT10501 1/0 / 19 420 1.198 1.318 1.318 1.478 0.08 99 92 967 210 170
A2/0-01MV35UT10501 2/0 / 19 420 1.242 1.362 1.362 1.522 0.08 125 95 1032 240 190
A3/0-01MV35UT10501 3/0 / 19 420 1.292 1.412 1.412 1.572 0.08 158 99 1109 275 220
A4/0-01MV35UT10501 4/0 / 19 420 1.348 1.468 1.468 1.628 0.08 199 104 1200 310 250
A250-01MV35UT10501 250 / 37 420 1.394 1.514 1.514 1.674 0.08 234 108 1381 345 275
A350-01MV35UT10501 350 / 37 420 1.497 1.617 1.617 1.777 0.08 329 116 1598 415 340
A500-01MV35UT10501 500 / 37 420 1.625 1.745 1.745 1.965 0.11 468 126 1865 510 410
A750-01MV35UT10501 750 / 61 420 1.816 1.936 1.936 2.156 0.11 703 142 2284 640 525
A1000-01MV35UT1051 1000 / 61 420 1.965 2.085 2.085 2.305 0.11 937 153 2666 745 615
(1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-97-682 for shielded power cables rated 5-46
kV and also meet the requirements of the latest revisions of AEIC CS8.
(2) Ampacity based on earth thermal resistivity of 90˚C-cm/watt, 105˚C conductor temp., 20˚C earth ambient temperature, 75% load factor and 36" depth of bur-
ial. Values are based on one three-phase circuit, one conductor per phase, in flat adjacent configuration (direct buried) with metallic shield bonded at each
end.
Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means
mass.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 314
Copyright © 2018, American Wire Group, Inc. 20160110
NOTES
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
PowerGuard® 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield
w/Ground PVC Jacket UL MV-105/AEIC CS8-07

Applications
Medium voltage power cables offer an economical, rugged and reliable alternative to labor-inten-
sive cable in conduit wiring methods.
Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not
more than six feet apart.
Installed in both exposed and concealed work, wet or dry locations, directly buried.

Construction
Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231.
Stranded conductors are water-blocked with conductor filling compound.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation
Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S-
94-649
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the in-
sulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield:The metallic shield is flat uncoated 5-mil thick copper tape helically applied with
minimum 20% overlap. A Mylar ribbon is longitudinally applied under the copper tape shield for
phase identification - 1C w/Red, 1C w/Blue, and 1C w/None.
Grounding Conductors: Three bare stranded copper conductor, one in each interstice.
Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core.
Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability.
Jacket: Black, sunlight resistant, flame retardant PVC jacket tightly applied over the binder tape.

MEDIUM VOLTAGE
Standards

CABLES
• AEIC CS8, Specifications for Shielded Power Cable, 5-46kV
• ICEA S-93-639, 5-46 kV Shielded Power Cable
• ICEA S-97-682, Utility Shielded Power Cable Rated 5-46 kV
• UL 1072 MV-105
• IEEE- IEEE 383 Flame Test
• For 105°C continuous, 140°C emergency, 250°C short-circuit operation.
• CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribu-
tion
NOTES:
Ampacities are based on three phase operation
In Duct (2011 NEC Table 310.15(B)(80): Three-conductor cable in plastic duct, direct-buried, 90°C con-
ductor temperature, 20°C ambient temperature, earth RHO of 90°C-cm/Watt, and 100% load factor,
and shields short-circuited.
Isolated in Air (2011 NEC Table 310.15(B)(72)): Three-conductor cable, 90°C conductor temperature,
and 40°C ambient temperature, and shields grounded at one point only.
In Cable Tray: Per 2011 NEC 392.80(B)(1)(b), for single conductor cables, sizes 1/0 AWG and larger, in-
stalled in a single layer in an uncovered table tray, with a maintained space of not less than one
cable diameter between individual conductors, the ampacities shall not exceed the allowable am-
pacities stated in 2011 NEC Table 310.15(B)(72) (Aluminum), “Isolated in Air” values noted above.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 316
Copyright © 2018, American Wire Group, Inc. 20150519
PowerGuard® 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield
w/Ground PVC Jacket UL MV-105/AEIC CS8-07

Item # Size Insulation No. of Size of Conductor Insulation Insulation Overall Approx. Minimum Ampacity Ampacity
AWG Thickness Ground Ground Diameter Diameter Shield Jacket Weight Bending 90°C 90°C
or (mil) Wires Wires (in) (in) (in) (in) (lb/MFT) Radius in Duct in Air
KCMIL (in)
5kV Copper 100%
4-03MV5GT10501 4 90 3 10 0.226 0.45 0.51 1.32 1097 10 100 105
2-03MV5GT10501 2 90 3 10 0.284 0.51 0.57 1.44 1412 11 135 140
1-03MV5GT10501 1 90 3 8 0.324 0.55 0.61 1.53 1682 11 155 160
1/0-03MV5GT10501 1/0 90 3 8 0.364 0.59 0.65 1.61 1948 12 175 185
2/0-03MV5GT10501 2/0 90 3 8 0.408 0.64 0.69 1.71 2271 12 200 215
3/0-03MV5GT10501 3/0 90 3 7 0.458 0.69 0.74 1.88 2812 14 230 250
4/0-03MV5GT10501 4/0 90 3 7 0.515 0.74 0.8 2 3317 15 265 285
250-03MV5GT10501 250 90 3 7 0.561 0.8 0.85 2.11 3761 15 290 320
350-03MV5GT10501 350 90 3 6 0.664 0.9 0.95 2.34 4918 17 355 395
500-03MV5GT10501 500 90 3 5 0.794 1.03 1.1 2.65 6668 19 430 485
750-03MV5GT10501 750 90 3 4 0.974 1.22 1.29 3.12 9629 22 530 615
1000-03MV5GT10501 1000 90 3 4 1.124 1.37 1.44 3.44 12287 25 600 705
5kV Copper 133%
4-03MV5UT10501 4 115 3 10 0.226 0.5 0.56 1.42 1193 10 100 105
2-03MV5UT10501 2 115 3 10 0.284 0.56 0.62 1.55 1515 11 135 140
1-03MV5UT10501 1 115 3 8 0.324 0.6 0.66 1.64 1789 12 155 160
MEDIUM VOLAGE

1/0-03MV5UT10501 1/0 115 3 8 0.364 0.64 0.7 1.78 2158 13 175 185
2/0-03MV5UT10501 2/0 115 3 8 0.408 0.69 0.74 1.88 2493 14 200 215
CABLES

3/0-03MV5UT10501 3/0 115 3 7 0.458 0.74 0.79 1.99 2941 14 230 250
4/0-03MV5UT10501 4/0 115 3 7 0.515 0.79 0.85 2.11 3453 15 265 285
250-03MV5UT10501 250 115 3 7 0.561 0.85 0.9 2.22 3903 16 290 320
350-03MV5UT10501 350 115 3 6 0.664 0.95 1 2.44 5072 18 355 395
500-03MV5UT10501 500 115 3 5 0.794 1.08 1.15 2.76 6839 20 430 485
750-03MV5UT10501 750 115 3 4 0.974 1.27 1.34 3.22 9829 23 530 615
1000-03MV5UT10501 1000 115 3 4 1.124 1.42 1.49 3.55 12504 25 600 705

8kV Copper 100%


4-03MV8GT10501 4 115 3 10 0.226 0.5 0.56 1.42 1193 10 115 120
2-03MV8GT10501 2 115 3 10 0.284 0.56 0.62 1.55 1515 11 150 165
1-03MV8GT10501 1 115 3 8 0.324 0.6 0.66 1.64 1789 12 170 185
1/0-03MV8GT10501 1/0 115 3 8 0.364 0.64 0.7 1.78 2158 13 195 215
2/0-03MV8GT10501 2/0 115 3 8 0.408 0.69 0.74 1.88 2493 14 220 245
3/0-03MV8GT10501 3/0 115 3 7 0.458 0.74 0.79 1.99 2941 14 250 285
4/0-03MV8GT10501 4/0 115 3 7 0.515 0.79 0.85 2.11 3453 15 285 325
250-03MV8GT10501 250 115 3 7 0.561 0.85 0.9 2.22 3903 16 310 360
350-03MV8GT10501 350 115 3 6 0.664 0.95 1 2.44 5072 18 375 435
500-03MV8GT10501 500 115 3 5 0.794 1.08 1.15 2.76 6839 20 450 535
750-03MV8GT10501 750 115 3 4 0.974 1.27 1.34 3.22 9829 23 545 670
1000-03MV8GT10501 1000 115 3 4 1.124 1.42 1.49 3.55 12504 25 615 770

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
316 Information on this sheet subject to change without notice.
20150519 Copyright © 2018, American Wire Group, Inc.
PowerGuard® 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield
w/Ground PVC Jacket UL MV-105/AEIC CS8-07

Item # Size Insulation No. of Size of Conductor Insulation Insulation Overall Approx. Minimum Ampacity Ampacity
AWG Thickness Ground Ground Diameter Diameter Shield Jacket Weight Bending 90°C 90°C
or (mil) Wires Wires (in) (in) (in) (in) (lb/MFT) Radius in Duct in Air
KCMIL (in)
8kV Copper 133%
2-03MV8UT10501 2 140 3 10 0.284 0.61 0.67 1.66 1623 12 150 165
1-03MV8UT10501 1 140 3 8 0.324 0.65 0.71 1.8 2002 13 170 185
1/0-03MV8UT10501 1/0 140 3 8 0.364 0.69 0.75 1.89 2282 14 195 215
2/0-03MV8UT10501 2/0 140 3 8 0.408 0.74 0.79 1.99 2622 14 220 245
3/0-03MV8UT10501 3/0 140 3 7 0.458 0.79 0.84 2.09 3076 15 250 285
4/0-03MV8UT10501 4/0 140 3 7 0.515 0.84 0.9 2.22 3594 16 285 325
250-03MV8UT10501 250 140 3 7 0.561 0.9 0.95 2.33 4051 17 310 360
350-03MV8UT10501 350 140 3 6 0.664 1 1.05 2.55 5232 18 375 435
500-03MV8UT10501 500 140 3 5 0.794 1.13 1.2 2.93 7180 21 450 535
750-03MV8UT10501 750 140 3 4 0.974 1.32 1.39 3.33 10034 24 545 670
1000-03MV8UT10501 1000 140 3 4 1.124 1.47 1.54 3.66 12728 26 615 770

15kV Copper 100%


2-03MV15GT10501 2 175 3 10 0.284 0.68 0.74 1.87 1888 14 150 165
1-03MV15GT10501 1 175 3 8 0.324 0.72 0.78 1.96 2179 14 170 185
1/0-03MV15GT10501 1/0 175 3 8 0.364 0.76 0.82 2.04 2466 15 195 215

MEDIUM VOLTAGE
2/0-03MV15GT10501 2/0 175 3 8 0.408 0.81 0.86 2.14 2813 15 220 245
3/0-03MV15GT10501 3/0 175 3 7 0.458 0.86 0.91 2.24 3275 16 250 285

CABLES
4/0-03MV15GT10501 4/0 175 3 7 0.515 0.91 0.97 2.37 3803 17 285 325
250-03MV15GT10501 250 175 3 7 0.561 0.97 1.02 2.48 4268 18 310 360
350-03MV15GT10501 350 175 3 6 0.664 1.07 1.14 2.74 5529 20 375 435
500-03MV15GT10501 500 175 3 5 0.794 1.2 1.27 3.08 7447 22 450 535
750-03MV15GT10501 750 175 3 4 0.974 1.39 1.46 3.48 10333 25 545 670
1000-03MV15GT10501 1000 175 3 4 1.124 1.54 1.62 3.84 13138 27 615 770
15kV Copper 133%
2-03MV15UT10501 2 220 3 10 0.284 0.77 0.83 2.06 2124 15 150 165
1-03MV15UT10501 1 220 3 8 0.324 0.81 0.87 2.15 2424 16 170 185
1/0-03MV15UT10501 1/0 220 3 8 0.364 0.85 0.91 2.24 2719 16 195 215
2/0-03MV15UT10501 2/0 220 3 8 0.408 0.9 0.95 2.33 3075 17 220 245
3/0-03MV15UT10501 3/0 220 3 7 0.458 0.95 1 2.44 3548 18 250 285
4/0-03MV15UT10501 4/0 220 3 7 0.515 1 1.06 2.56 4088 18 285 325
250-03MV15UT10501 250 220 3 7 0.561 1.06 1.13 2.71 4627 19 310 360
350-03MV15UT10501 350 220 3 6 0.664 1.16 1.23 2.99 6018 21 375 435
500-03MV15UT10501 500 220 3 5 0.794 1.29 1.36 3.27 7808 23 450 535
750-03MV15UT10501 750 220 3 4 0.974 1.48 1.55 3.68 10733 26 545 670
1000-03MV15UT10501 1000 220 3 4 1.124 1.63 1.71 4.04 13574 29 615 770

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 316
Copyright © 2018, American Wire Group, Inc. 20150519
PowerGuard® 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield
w/Ground PVC Jacket UL MV-105/AEIC CS8-07

Item # Size Insulation No. of Size of Conductor Insulation Insulation Overall Approx. Minimum Ampacity Ampacity
AWG Thickness Ground Ground Diameter Diameter Shield Jacket Weight Bending 90°C 90°C
or (mil) Wires Wires (in) (in) (in) (in) (lb/MFT) Radius in Duct in Air
KCMIL (in)
25kV Copper 100%
1-03MV25GT10501 1 260 3 8 0.324 0.89 0.95 2.32 2657 17 170 185
1/0-03MV25GT10501 1/0 260 3 8 0.364 0.93 0.99 2.41 2960 17 195 215
2/0-03MV25GT10501 2/0 260 3 8 0.408 0.98 1.03 2.5 3324 18 220 245
3/0-03MV25GT10501 3/0 260 3 7 0.458 1.03 1.1 2.65 3868 19 250 285
4/0-03MV25GT10501 4/0 260 3 7 0.515 1.08 1.16 2.77 4421 20 285 325
250-03MV25GT10501 250 260 3 7 0.561 1.14 1.21 2.94 5073 21 310 360
350-03MV25GT10501 350 260 3 6 0.664 1.24 1.31 3.16 6330 23 375 435
500-03MV25GT10501 500 260 3 5 0.794 1.37 1.44 3.45 8144 25 450 535
750-03MV25GT10501 750 260 3 4 0.974 1.56 1.64 3.89 11193 28 545 670
1000-03MV25GT10501 1000 260 3 4 1.124 1.71 1.79 4.21 13978 30 615 770
25kV Copper 133%
1/0-03MV25UT10501 1/0 345 3 8 0.364 1.11 1.18 2.88 3761 21 195 215
2/0-03MV25UT10501 2/0 345 3 8 0.408 1.15 1.22 2.97 4151 21 220 245
3/0-03MV25UT10501 3/0 345 3 7 0.458 1.2 1.27 3.08 4662 22 250 285
4/0-03MV25UT10501 4/0 345 3 7 0.515 1.26 1.33 3.21 5245 23 285 325
250-03MV25UT10501 250 345 3 7 0.561 1.31 1.38 3.32 5762 24 310 360
MEDIUM VOLAGE

350-03MV25UT10501 350 345 3 6 0.664 1.41 1.48 3.54 7060 25 375 435
500-03MV25UT10501 500 345 3 5 0.794 1.54 1.63 3.86 9015 27 450 535
CABLES

35kV Copper 100%


1/0-03MV35GT10501 1/0 345 3 8 0.364 1.11 1.18 2.88 3761 21 195 215
2/0-03MV35GT10501 2/0 345 3 8 0.408 1.15 1.22 2.97 4151 21 220 245
3/0-03MV35GT10501 3/0 345 3 7 0.458 1.2 1.27 3.08 4662 22 250 285
4/0-03MV35GT10501 4/0 345 3 7 0.515 1.26 1.33 3.21 5245 23 285 325
250-03MV35GT10501 250 345 3 7 0.561 1.31 1.38 3.32 5762 24 310 360
350-03MV35GT10501 350 345 3 6 0.664 1.41 1.48 3.54 7060 25 375 435
500-03MV35GT10501 500 345 3 5 0.794 1.54 1.63 3.86 9015 27 450 535
35kV Copper 133%
1/0-03MV35UT10501 1/0 420 3 8 0.364 1.26 1.33 3.21 4356 23 195 215
2/0-03MV35UT10501 2/0 420 3 8 0.408 1.3 1.38 3.31 4761 24 220 245
3/0-03MV35UT10501 3/0 420 3 7 0.458 1.35 1.43 3.41 5291 24 250 285
4/0-03MV35UT10501 4/0 420 3 7 0.515 1.41 1.48 3.54 5895 25 285 325
250-03MV35UT10501 250 420 3 7 0.561 1.46 1.54 3.65 6430 26 310 360
350-03MV35UT10501 350 420 3 6 0.664 1.57 1.65 3.91 7854 28 375 435
500-03MV35UT10501 500 420 3 5 0.794 1.7 1.78 4.19 9775 30 450 535

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
316 Information on this sheet subject to change without notice.
20150519 Copyright © 2018, American Wire Group, Inc.
PowerGuard® 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield
w/Ground PVC Jacket UL MV-105/AEIC CS8-07

Applications
Medium-Voltage power cables offer an economical, rugged and reliable alternative to labor-inten-
sive cable in conduit wiring methods.
Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not
more than six feet apart.
Installed in both exposed and concealed work, wet or dry locations, directly buried.

Construction
Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231.
Stranded conductors are water-blocked with conductor filling compound.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation
Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S-
94-649
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the in-
sulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield:The metallic shield is flat uncoated 5-mil thick copper tape helically applied with
minimum 20% overlap. A Mylar ribbon is longitudinally applied under the copper tape shield for
phase identification - 1C w/Red, 1C w/Blue, and 1C w/None.
Grounding Conductors: Three bare stranded copper conductor, one in each interstice.
Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core.
Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability.
Jacket: Black, sunlight resistant, flame retardant PVC jacket tightly applied over the binder tape.

MEDIUM VOLTAGE
Standards

CABLES
• AEIC CS8, Specifications for Shielded Power Cable, 5-46kV
• ICEA S-93-639, 5-46 kV Shielded Power Cable
• ICEA S-97-682, Utility Shielded Power Cable Rated 5-46 kV
• UL 1072 MV-105
• IEEE- IEEE 383 Flame Test
• For 105°C continuous, 140°C emergency, 250°C short-circuit operation.
• CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribu-
tion
NOTES:
Ampacities are based on three Phase Operation
In Duct (2011 NEC Table 310.15(B)(80): Three-conductor cable in plastic duct, direct-buried, 90°C con-
ductor temperature, 20°C ambient temperature, earth RHO of 90°C-cm/Watt, and 100% load factor,
and shields short-circuited.
Isolated in Air (2011 NEC Table 310.15(B)(72)): Three-conductor cable, 90°C conductor temperature,
and 40°C ambient temperature, and shields grounded at one point only.
In Cable Tray: Per 2011 NEC 392.80(B)(1)(b), for single conductor cables, sizes 1/0 AWG and larger, in-
stalled in a single layer in an uncovered table tray, with a maintained space of not less than one
cable diameter between individual conductors, the ampacities shall not exceed the allowable am-
pacities stated in 2011 NEC Table 310.15(B)(72) (Aluminum), “Isolated in Air” values noted above.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 317
Copyright © 2018, American Wire Group, Inc. 20150519
PowerGuard® 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield
w/Ground PVC Jacket UL MV-105/AEIC CS8-07

Item # Size Insulation No. of Size of Conductor Insulation Insulation Overall Approx. Minimum Ampacity Ampacity
AWG Thickness Ground Ground Diameter Diameter Shield Jacket Weight Bending 90°C 90°C
or (mil) Wires Wires (in) (in) (in) (in) (lb/MFT) Radius in Duct in Air
KCMIL (in)
5kV Aluminum 100%
A4-03MV5GT10501 4 90 3 10 0.226 0.45 0.51 1.32 833 10 80 81
A2-03MV5GT10501 2 90 3 10 0.284 0.51 0.57 1.44 993 11 105 110
A1-03MV5GT10501 1 90 3 10 0.324 0.55 0.61 1.53 1093 11 120 125
A1/0-03MV5GT10501 1/0 90 3 10 0.364 0.59 0.65 1.61 1218 12 140 145
A2/0-03MV5GT10501 2/0 90 3 8 0.408 0.64 0.69 1.77 1522 13 160 170
A3/0-03MV5GT10501 3/0 90 3 8 0.458 0.69 0.74 1.88 1705 14 180 195
A4/0-03MV5GT10501 4/0 90 3 8 0.515 0.74 0.8 2 1930 15 205 225
A250-03MV5GT10501 250 90 3 8 0.561 0.8 0.85 2.11 2131 15 230 250
A350-03MV5GT10501 350 90 3 7 0.664 0.9 0.95 2.34 2643 17 280 310
A500-03MV5GT10501 500 90 3 6 0.794 1.03 1.1 2.65 3424 19 340 385
A750-03MV5GT10501 750 90 3 5 0.974 1.22 1.29 3.12 4755 22 425 495
A1000-03MV5GT10501 1000 90 3 4 1.124 1.37 1.44 3.44 5886 25 495 585
5kV Aluminum 133%
A4-03MV5UT10501 4 115 3 10 0.226 0.5 0.56 1.42 929 10 80 81
A2-03MV5UT10501 2 115 3 10 0.284 0.56 0.62 1.55 1095 11 105 110
A1-03MV5UT10501 1 115 3 10 0.324 0.6 0.66 1.64 1200 12 120 125
MEDIUM VOLAGE

A1/0-03MV5UT10501 1/0 115 3 10 0.364 0.64 0.7 1.78 1429 13 140 145
A2/0-03MV5UT10501 2/0 115 3 8 0.408 0.69 0.74 1.88 1645 14 160 170
CABLES

A3/0-03MV5UT10501 3/0 115 3 8 0.458 0.74 0.79 1.99 1834 14 180 195
A4/0-03MV5UT10501 4/0 115 3 8 0.515 0.79 0.85 2.11 2066 15 205 225
A250-03MV5UT10501 250 115 3 8 0.561 0.85 0.9 2.22 2273 16 230 250
A350-03MV5UT10501 350 115 3 7 0.664 0.95 1 2.44 2797 18 280 310
A500-03MV5UT10501 500 115 3 6 0.794 1.08 1.15 2.76 3595 20 340 385
A750-03MV5UT10501 750 115 3 5 0.974 1.27 1.34 3.22 4955 23 425 495
A1000-03MV5UT10501 1000 115 3 4 1.124 1.42 1.49 3.55 6103 25 495 585

8kV Aluminum 100%


A4-03MV8GT10501 4 115 3 10 0.226 0.5 0.56 1.42 929 10 89 95
A2-03MV8GT10501 2 115 3 10 0.284 0.56 0.62 1.55 1095 11 115 125
A1-03MV8GT10501 1 115 3 10 0.324 0.6 0.66 1.64 1200 12 135 145
A1/0-03MV8GT10501 1/0 115 3 10 0.364 0.64 0.7 1.78 1429 13 150 170
A2/0-03MV8GT10501 2/0 115 3 8 0.408 0.69 0.74 1.88 1645 14 170 190
A3/0-03MV8GT10501 3/0 115 3 8 0.458 0.74 0.79 1.99 1834 14 195 220
A4/0-03MV8GT10501 4/0 115 3 8 0.515 0.79 0.85 2.11 2066 15 220 255
A250-03MV8GT10501 250 115 3 8 0.561 0.85 0.9 2.22 2273 16 245 280
A350-03MV8GT10501 350 115 3 7 0.664 0.95 1 2.44 2797 18 295 345
A500-03MV8GT10501 500 115 3 6 0.794 1.08 1.15 2.76 3595 20 355 425
A750-03MV8GT10501 750 115 3 5 0.974 1.27 1.34 3.22 4955 23 440 540
A1000-03MV8GT10501 1000 115 3 4 1.124 1.42 1.49 3.55 6103 25 510 635

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
317 Information on this sheet subject to change without notice.
20150519 Copyright © 2018, American Wire Group, Inc.
PowerGuard® 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield
w/Ground PVC Jacket UL MV-105/AEIC CS8-07

Item # Size Insulation No. of Size of Conductor Insulation Insulation Overall Approx. Minimum Ampacity Ampacity
AWG Thickness Ground Ground Diameter Diameter Shield Jacket Weight Bending 90°C 90°C
or (mil) Wires Wires (in) (in) (in) (in) (lb/MFT) Radius in Duct in Air
KCMIL (in)
8kV Aluminum 133%
A2-03MV8UT10501 2 140 3 10 0.284 0.61 0.67 1.66 1204 12 115 125
A1-03MV8UT10501 1 140 3 10 0.324 0.65 0.71 1.8 1413 13 135 145
A1/0-03MV8UT10501 1/0 140 3 10 0.364 0.69 0.75 1.89 1553 14 150 170
A2/0-03MV8UT10501 2/0 140 3 8 0.408 0.74 0.79 1.99 1774 14 170 190
A3/0-03MV8UT10501 3/0 140 3 8 0.458 0.79 0.84 2.09 1969 15 195 220
A4/0-03MV8UT10501 4/0 140 3 8 0.515 0.84 0.9 2.22 2208 16 220 255
A250-03MV8UT10501 250 140 3 8 0.561 0.9 0.95 2.33 2421 17 245 280
A350-03MV8UT10501 350 140 3 7 0.664 1 1.05 2.55 2957 18 295 345
A500-03MV8UT10501 500 140 3 6 0.794 1.13 1.2 2.93 3936 21 355 425
A750-03MV8UT10501 750 140 3 5 0.974 1.32 1.39 3.33 5161 24 440 540
A1000-03MV8UT10501 1000 140 3 4 1.124 1.47 1.54 3.66 6327 26 510 635

15kV Aluminum 100%


A2-03MV15GT10501 2 175 3 10 0.284 0.68 0.74 1.87 1469 14 115 125
A1-03MV15GT10501 1 175 3 10 0.324 0.72 0.78 1.96 1590 14 135 145
A1/0-03MV15GT10501 1/0 175 3 10 0.364 0.76 0.82 2.04 1736 15 150 170

MEDIUM VOLTAGE
A2/0-03MV15GT10501 2/0 175 3 8 0.408 0.81 0.86 2.14 1965 15 170 190
A3/0-03MV15GT10501 3/0 175 3 8 0.458 0.86 0.91 2.24 2168 16 195 220

CABLES
A4/0-03MV15GT10501 4/0 175 3 8 0.515 0.91 0.97 2.37 2416 17 220 255
A250-03MV15GT10501 250 175 3 8 0.561 0.97 1.02 2.48 2638 18 245 280
A350-03MV15GT10501 350 175 3 7 0.664 1.07 1.14 2.74 3254 20 295 345
A500-03MV15GT10501 500 175 3 6 0.794 1.2 1.27 3.08 4203 22 355 425
A750-03MV15GT10501 750 175 3 5 0.974 1.39 1.46 3.48 5459 25 440 540
A1000-03MV15GT10501 1000 175 3 4 1.124 1.54 1.62 3.84 6737 27 510 635
15kV Aluminum 133%
A2-03MV15UT10501 2 220 3 10 0.284 0.77 0.83 2.06 1705 15 115 125
A1-03MV15UT10501 1 220 3 10 0.324 0.81 0.87 2.15 1834 16 135 145
A1/0-03MV15UT10501 1/0 220 3 10 0.364 0.85 0.91 2.24 1989 16 150 170
A2/0-03MV15UT10501 2/0 220 3 8 0.408 0.9 0.95 2.33 2227 17 170 190
A3/0-03MV15UT10501 3/0 220 3 8 0.458 0.95 1 2.44 2441 18 195 220
A4/0-03MV15UT10501 4/0 220 3 8 0.515 1 1.06 2.56 2701 18 220 255
A250-03MV15UT10501 250 220 3 8 0.561 1.06 1.13 2.71 2997 19 245 280
A350-03MV15UT10501 350 220 3 7 0.664 1.16 1.23 2.99 3743 21 295 345
A500-03MV15UT10501 500 220 3 6 0.794 1.29 1.36 3.27 4564 23 355 425
A750-03MV15UT10501 750 220 3 5 0.974 1.48 1.55 3.68 5859 26 440 540
A1000-03MV15UT10501 1000 220 3 4 1.124 1.63 1.71 4.04 7173 29 510 635

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 317
Copyright © 2018, American Wire Group, Inc. 20150519
PowerGuard® 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield
w/Ground PVC Jacket UL MV-105/AEIC CS8-07

Item # Size Insulation No. of Size of Conductor Insulation Insulation Overall Approx. Minimum Ampacity Ampacity
AWG Thickness Ground Ground Diameter Diameter Shield Jacket Weight Bending 90°C 90°C
or (mil) Wires Wires (in) (in) (in) (in) (lb/MFT) Radius in Duct in Air
KCMIL (in)
25kV Aluminum 100%
A1-03MV25GT10501 1 260 3 10 0.324 0.89 0.95 2.32 2068 17 135 145
A1/0-03MV25GT10501 1/0 260 3 10 0.364 0.93 0.99 2.41 2230 17 150 170
A2/0-03MV25GT10501 2/0 260 3 8 0.408 0.98 1.03 2.5 2476 18 170 190
A3/0-03MV25GT10501 3/0 260 3 8 0.458 1.03 1.1 2.65 2761 19 195 220
A4/0-03MV25GT10501 4/0 260 3 8 0.515 1.08 1.16 2.77 3034 20 220 255
A250-03MV25GT10501 250 260 3 8 0.561 1.14 1.21 2.94 3444 21 245 280
A350-03MV25GT10501 350 260 3 7 0.664 1.24 1.31 3.16 4055 23 295 345
A500-03MV25GT10501 500 260 3 6 0.794 1.37 1.44 3.45 4900 25 355 425
A750-03MV25GT10501 750 260 3 5 0.974 1.56 1.64 3.89 6319 28 440 540
A1000-03MV25GT10501 1000 260 3 4 1.124 1.71 1.79 4.21 7577 30 510 635
25kV Aluminum 133%
A1/0-03MV25UT10501 1/0 345 3 10 0.364 1.11 1.18 2.88 3031 21 150 170
A2/0-03MV25UT10501 2/0 345 3 8 0.408 1.15 1.22 2.97 3303 21 170 190
A3/0-03MV25UT10501 3/0 345 3 8 0.458 1.2 1.27 3.08 3555 22 195 220
A4/0-03MV25UT10501 4/0 345 3 8 0.515 1.26 1.33 3.21 3859 23 220 255
A250-03MV25UT10501 250 345 3 8 0.561 1.31 1.38 3.32 4132 24 245 280
MEDIUM VOLAGE

A350-03MV25UT10501 350 345 3 7 0.664 1.41 1.48 3.54 4785 25 295 345
A500-03MV25UT10501 500 345 3 6 0.794 1.54 1.63 3.86 5771 27 355 425
CABLES

35kV Aluminum 100%


A1/0-03MV35GT10501 1/0 345 3 10 0.364 1.11 1.18 2.88 3031 21 150 170
A2/0-03MV35GT10501 2/0 345 3 8 0.408 1.15 1.22 2.97 3303 21 170 190
A3/0-03MV35GT10501 3/0 345 3 8 0.458 1.2 1.27 3.08 3555 22 195 220
A4/0-03MV35GT10501 4/0 345 3 8 0.515 1.26 1.33 3.21 3859 23 220 255
A250-03MV35GT10501 250 345 3 8 0.561 1.31 1.38 3.32 4132 24 245 280
A350-03MV35GT10501 350 345 3 7 0.664 1.41 1.48 3.54 4785 25 295 345
A500-03MV35GT10501 500 345 3 6 0.794 1.54 1.63 3.86 5771 27 355 425
35kV Aluminum 133%
A1/0-03MV35UT10501 1/0 420 3 10 0.364 1.26 1.33 3.21 3626 23 150 170
A2/0-03MV35UT10501 2/0 420 3 8 0.408 1.3 1.38 3.31 3914 24 170 190
A3/0-03MV35UT10501 3/0 420 3 8 0.458 1.35 1.43 3.41 4184 24 195 220
A4/0-03MV35UT10501 4/0 420 3 8 0.515 1.41 1.48 3.54 4509 25 220 255
A250-03MV35UT10501 250 420 3 8 0.561 1.46 1.54 3.65 4800 26 245 280
A350-03MV35UT10501 350 420 3 7 0.664 1.57 1.65 3.91 5580 28 295 345
A500-03MV35UT10501 500 420 3 6 0.794 1.7 1.78 4.19 6531 30 355 425

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
317 Information on this sheet subject to change without notice.
20150519 Copyright © 2018, American Wire Group, Inc.
PowerGuard® 15kV 133% Shielded Power Cable
AL Conductor 220 mils EPR Copper Tape
PVC Jacket MV-105

Applications Standards
For installation in tray, trough, conduit, ducts, • National Electrical Code (NEC)
aerial and direct buried as allowed by the NEC. • UL-1072 MV-105
The cables can be used in main feeder, distribu- • ICEA S-93-639/NEMA WC74
tion, and branch circuits for industrial, commer- • ICEA S-97-682
cial and electric utility installations. They may • AEIC CS8
operate continuously in wet or dry locations at • UL listed as Type MV-105 for use in accordance
conductor temperatures not exceeding 105°C, at with NEC
not more than 140°C. for emergency overload • Sizes 1/0 AWG and larger are listed and
conditions and 250°C during short circuits. Suit- marked “Sunlight-Resistant FOR CT USE” in
able for systems rated 15 kV 100% insulation accordance with NEC
level (grounded systems). Suitable for Direct
Burial. Sunlight Resistant. Notes
• Ampacities are based on the NEC.
Construction • Cable Tray: Three single cables, installed in un-
Aluminum concentrically stranded compressed covered cable tray in accordance with NEC
conductor; triple single head extruded conduc- Section 392.13; operating at 105°C conductor,
tor shield, EPR (ethylene propylene rubber) in- at an ambient temperature of 40°C.
sulation and easy strippable insulation shield, • Buried Duct: Three cables per duct operating

earth ρ = 90, 100% load factor.


all dry cured; bare copper tape shielded; surface at 105°C conductor, 20°C ground ambient,
printed black PVC jacket.
• Conduit in Air: Three cables per isolated con-
duit in air at 40°C; operating at 105°C conduc-
tor (NEC Table 310.73).

MEDIUM VOLTAGE
CABLES
Item # Size/AWG Insulation Conductor Insulation Overall Approx. Insulation Ampacity Ampacity
Thickness Diameter Diameter Diameter Weight Shield (Amps) (Amps)
(in) (in) (in) (in) lb/MFT (in) 105°C 105C
in Duct in Air
A2-01PC15EPPU2 2 .220 .266 0.74 0.96 484 0.80 130 170
A1/0-01PC15EPPU2 1/0 .220 .336 0.81 1.03 566 0.87 165 225
A2/0-01PC15EPPU2 2/0 .220 .379 0.86 1.08 620 0.91 190 260
A4/0-01PC15EPPU2 4/0 .220 .479 0.96 1.18 761 1.01 245 350
A250-01PC15EPPU2 250 .220 .522 1.01 1.23 834 1.06 270 385
A350-01PC15EPPU2 350 .220 .622 1.11 1.33 992 1.16 330 480
A500-01PC15EPPU2 500 .220 .742 1.23 1.45 1216 1.28 400 600
A750-01PC15EPPU2 750 .220 .917 1.41 1.63 1574 1.47 490 780
A1000-01PC15EPPU2 1000 .220 1.071 1.57 1.84 2028 1.62 565 940

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 319
Copyright © 2018, American Wire Group, Inc. 20160302
NOTES
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
PowerGuard®
Testing Recommendations

June 7, 2016
Regarding field testing cables for commissioning, we recommend the VLF Testing in Accordance to
IEEE 400: IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Sys-
tems in accordance to Table 1 IEEE400.2 VLF Test Voltage Levels for Sinusoidal, Cosine-Rectangular.
Voltage Peak values are shown in brackets for Cosine-Rectangular and Squarewave.
The most important application part of the new IEEE400.2 cable testing guide is the Table 1 below
that shows the recommended VLF Hipot voltage testing levels for the various medium voltage cable
ratings for both new (Acceptance and Installation Testing) and old (Maintenance Testing) cable in-
stallations.
This is a Pass/Fail type test, the cable either withstands the specified test voltage or it does not.
The IEEE400 defines types of field tests:
Installation Test
This test is conducted after the installation of the cable but before the installation ofaccessories like
the splices and terminations. Its purpose is to detect any transport, manufacturing, storage or instal-
lation defects.
Acceptance Test
This test is performed after the installation of the accessories, but before energization ofthe cable. It
checks for installation defects of the complete cable system, as well as defects as a result of ship-
ping, manufacturing or storage.
Test Frequency
VLF test frequency is 0.1Hz of a testing of 30 minutes.

MEDIUM VOLTAGE
Cable Rating Installation Test Acceptance Test Maintenance Test

CABLES
phase to phase phase to ground phase to ground phase to ground
(RMS)
kV rms kV rms (or peak) kV rms (or peak) kV rms (or peak)
5 9 (13) 10 (14) 7 (10)
8 11 (16) 13 (18) 10 (14)
15 18 (25) 20 (28) 16 (22)
25 27 (38) 31 (44) 23 (33)
35 39 (55) 44 (62) 33 (47)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 321
Copyright © 2018, American Wire Group, Inc. 20170306
MEDIUM VOLAGE
CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
ARMORED CABLES
Table of Contents

UL Type MC Two Conductor Aluminum with Ground PVC Jacket 600V ............................236
UL Type MC Three Conductor Aluminum with Ground PVC Jacket 600V .........................237
UL Type MC Four Conductor Aluminum with Ground PVC Jacket 600V...........................238
UL Type MC Two Conductor Aluminum with Ground PVC Jacket 2kV ..............................235
Type MC Three Conductor w/Ground Aluminum Armor XHHW2 600V.............................911
Type MC Four Conductor w/Ground Aluminum Armor XHHW-2 600V.............................912
PowerGuard® Armored Copper Three Conductor 5kV-35kV ..............................................903
PowerGuard® Armored Aluminum Three Conductor 5kV-35kV .........................................904
Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2),
600V/1kV, Type MC-HL 1/C.....................................................................................................905
Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2),
600V/1kV, Type MC-HL 2/C.....................................................................................................906
Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2),
600V/1kV, Type MC-HL 3/C.....................................................................................................907
Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2),
600V/1kV, Type MC-HL 4/C.....................................................................................................908
Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2),
600V/1kV, Type MC-HL 5/C.....................................................................................................909
UL Type MC Copper Conductor with Ground PVC Jacket 600V .........................................910

ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 900
Copyright © 2018, American Wire Group, Inc. 20180201
NOTES
ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
UL Type MC Two Conductor Aluminum with Ground
PVC Jacket 600V

Applications Flame retardant thermoset crosslinked polyeth-


MC Cable is approved for use in many applica- ylene (XLPE) insulation. Grounding is one bare
tions including direct burial, use in cable tray aluminum alloy (AA-8000) compacted stranded
and outdoor exposure. The PVC jacket is free of conductor. Phase and grounding conductors are
harmful heavy metals in compliance with RoHS, cabled together with binder tape. Aluminum in-
Directive 2002/95/EC. terlocked armor, applied over the binder tape
• Run from the combiner box to the inverter and a longitudinal marker tape, for ID, when un-
• Suitable for rooftop solar applications jacketed. Black sunlight resistant and flame re-
• Outdoors tardant polyvinyl chloride (PVC) compound
• In wet locations (Type XHHW-2, or RHW-2 jacket.
conductors) Standards
• Direct buried • Single conductors are rated XHHW-2 600V,
• Encased in concrete and CT Use 1/0AWG and larger. Additional UL
• Hazardous locations Type PV available upon request.
• Strong, but lightweight alloy armor resists • Aluminum armor is rated for Direct Burial,
damage using 6AWG and larger conductors, with over-
• Suitable for wet locations, direct burial, en- all jacket
cased in concrete and other uses per the NEC • UL Type MC-HL available upon request of pur-
• More flexible than conduit chaser where cable is approved for use in cer-
• Factory tested engineered product that pro- tain hazardous locations as permitted in
tects conductors from damage during installa- articles 501, 502, 503 and 504
tion • UL 1569, Metal Clad Cables
• Meets or exceeds requirements of the NEC, as • UL 44, Rubber-Insulated wires and cables
well as applicable UL Standards. • ICEA S-95-658 Standard for Non-shielded
Construction Power Cables Rated 2000 volts or less
Stranded aluminum alloy (AA8000) compacted
conductor, Class B stranding, per ASTM B 801.

Item # Conductor Grounding Cable Cable Cable Cable


Size Conductor Diameter Diameter Diameter Weight
AWG/ AWG/ Under Armor Over Armor Over PVC (lb/MFT)

ARMORED CABLES
kcmil kcmil (in) (in) Jacket
(in)
A6-02AIA-WG-600V 6 8 0.56 0.75 0.85 243.5
A4-02AIA-WG-600V 4 6 0.65 0.84 0.94 306.5
A2-02AIA-WG-600V 2 6 0.76 0.95 1.05 383.9
A1-02AIA-WG-600V 1 4 0.86 1.05 1.15 472.9
A1/0-02AIA-WG-600V 1/0 4 0.93 1.12 1.22 537.5
A2/0-02AIA-WG-600V 2/0 4 1.01 1.21 1.31 626.4
A3/0-02AIA-WG-600V 3/0 4 1.11 1.3 1.4 723.1
A4/0-02AIA-WG-600V 4/0 2 1.21 1.41 1.51 864.8
A250-02AIA-WG-600V 250 2 1.34 1.6 1.72 1048
A300-02AIA-WG-600V 300 2 1.44 1.7 1.82 1180.5
A350-02AIA-WG-600V 350 2 1.53 1.79 1.91 1310.3
A400-02AIA-WG-600V 400 1 1.62 1.88 2 1431.2
A500-02AIA-WG-600V 500 1 1.77 2.03 2.15 1674.6
A750-02AIA-WG-600V 750 1/0 2.18 2.43 2.58 2417
Data isApproximateAnd subject to normal manufacturing tolerances. For sizes not listedAbove please contact sales.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 236
Copyright © 2018, American Wire Group, Inc. 20140924
NOTES
ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
.
UL Type MC Three Conductor Aluminum with Ground
PVC Jacket 600V

Applications Flame retardant thermoset crosslinked polyeth-


MC Cable is approved for use in many applica- ylene (XLPE) insulation. Grounding is one bare
tions including direct burial, use in cable tray aluminum alloy (AA-8000) compacted stranded
and outdoor exposure. The PVC jacket is free of conductor. Phase and grounding conductors are
harmful heavy metals in compliance with RoHS, cabled together with binder tape. aluminum in-
Directive 2002/95/EC. terlocked armor, applied over the binder tape
• Run from the combiner box to the inverter and a longitudinal marker tape, for ID, when un-
• Suitable for rooftop solar applications jacketed. Black sunlight resistant and flame re-
• Outdoors tardant polyvinyl chloride (PVC) compound
• In wet locations (Type XHHW-2, or RHW-2 jacket.
conductors) Specifications
• Direct buried • Single conductors are rated XHHW-2 600V,
• Encased in concrete and CT Use 1/0AWG and larger. Additional UL
• Hazardous locations Type PV available upon request.
• Strong, but lightweight alloy armor resists • Aluminum armor is rated for Direct Burial,
damage using 6AWG and larger conductors, with over-
• Suitable for wet locations, direct burial, en- all jacket
cased in concrete and other uses per the NEC • UL Type MC-HL available upon request of pur-
• More flexible than conduit chaser where cable is approved for use in cer-
• Factory tested engineered product that pro- tain hazardous locations as permitted in
tects conductors from damage during installa- articles 501, 502, 503 and 504
tion • UL 1569, Metal Clad Cables
• Meets or exceeds requirements of the NEC, as • UL 44, Rubber-Insulated wires and cables
well as applicable UL Standards • ICEA S-95-658 Standard for Non-shielded
Construction Power Cables Rated 2000 volts or less
Stranded aluminum alloy (AA8000) compacted
conductor, Class B stranding, per ASTM B 801.

Item # Conductor Grounding Cable Cable Cable Cable


Size Conductor Diameter Diameter Diameter Weight

ARMORED CABLES
AWG/ AWG/ Under Armor Over Armor Over PVC (lb/MFT)
kcmil kcmil (in) (in) Jacket
(in)
A4-03AIA-WG-600V 4 6 0.68 0.09 1.00 380
A2-03AIA-WG-600V 2 6 0.77 1.00 1.09 482
A1-03AIA-WG-600V 1 4 0.90 1.12 1.22 595
A1/0-03AIA-WG-600V 1/0 4 0.96 1.18 1.28 691
A2/0-03AIA-WG-600V 2/0 4 1.05 1.28 1.38 813
A3/0-03AIA-WG-600V 3/0 4 1.13 1.36 1.46 950
A40-03AIA-WG-600V 40 2 1.27 1.55 1.67 1176
A250-03AIA-WG-600V 250 2 1.40 1.69 1.81 1381
A300-03AIA-WG-600V 300 2 1.51 1.79 1.91 1570
A350-03AIA-WG-600V 350 2 1.61 1.89 2.01 1755
A400-03AIA-WG-600V 400 2 1.70 1.99 2.11 1919
A500-03AIA-WG-600V 500 1 1.87 2.15 2.72 2269
A600-03AIA-WG-600V 600 1 2.10 2.38 2.53 2766
A700-03AIA-WG-600V 700 1/0 2.24 2.52 2.67 3134
A750-03AIA-WG-600V 750 1/0 2.30 2.59 2.74 3306
A900-03AIA-WG-600V 900 250 2.50 2.78 2.93 3959
Data is approximate and subject to normal manufacturing tolerances. For sizes not listed above please contact sales.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 237
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
UL Type MC Four Conductor Aluminum with Ground
PVC Jacket 600V

Applications Flame retardant thermoset crosslinked polyeth-


MC Cable is approved for use in many applica- ylene (XLPE) insulation. Grounding is one bare
tions including direct burial, use in cable tray aluminum alloy (AA-8000) compacted stranded
and outdoor exposure. The PVC jacket is free of conductor. Phase and grounding conductors are
harmful heavy metals in compliance with RoHS, cabled together with binder tape. Aluminum in-
Directive 2002/95/EC. terlocked armor, applied over the binder tape
• Run from the combiner box to the inverter and a longitudinal marker tape, for ID, when un-
• Suitable for rooftop solar applications jacketed. Black sunlight resistant and flame re-
• Outdoors tardant polyvinyl chloride (PVC) compound
• In wet locations (Type XHHW-2 , or RHW-2 jacket.
conductors) Specifications
• Direct buried • Single conductors are rated XHHW-2 600V,
• Encased in concrete and CT Use 1/0AWG and larger. Additional UL
• Hazardous locations Type PV available upon request.
• Strong, but lightweight alloy armor resists • Aluminum armor is rated for Direct Burial,
damage using 6AWG and larger conductors, with over-
• Suitable for wet locations, direct burial, en- all jacket
cased in concrete and other uses per the NEC • UL Type MC-HL available upon request of pur-
• More flexible than conduit chaser where cable is approved for use in cer-
• Factory tested engineered product that pro- tain hazardous locations as permitted in
tects conductors from damage during installa- articles 501, 502, 503 and 504
tion • UL 1569, Metal Clad Cables
• Meets or exceeds requirements of the NEC, as • UL 44, Rubber-Insulated wires and cables
well as applicable UL Standards • ICEA S-95-658 Standard for Non-shielded
Construction Power Cables Rated 2000 volts or less
Stranded aluminum alloy (AA8000) compacted
conductor, Class B stranding, perASTM B 801.

Item # Conductor Grounding Cable Cable Cable Cable


Size Conductor Diameter Diameter Diameter Weight
AWG/ AWG/ Under Armor Over Armor Over PVC (lb/MFT)
kcmil kcmil (in) (in) Jacket

ARMORED CABLES
(in)
A6-04AIA-WG-600V 6 6 0.70 0.92 1.02 377
A4-04AIA-WG-600V 4 6 0.77 1.04 1.09 474
A2-04AIA-WG-600V 2 6 0.89 1.10 1.20 617
A1-04AIA-WG-600V 1 4 1.03 1.25 1.35 757
A1/0-04AIA-WG-600V 1/0 4 1.11 1.34 1.43 871
A2/0-04AIA-WG-600V 2/0 4 1.19 1.41 1.51 1071
A3/0-04AIA-WG-600V 3/0 4 1.32 1.58 1.70 1235
A40-04AIA-WG-600V 4/0 2 1.46 1.73 1.85 1480
A250-04AIAWG-600V 250 1 1.60 1.89 2.01 1730
A300-04AIAWG-600V 300 1 1.70 1.99 2.11 1970
A350-04AIAWG-600V 350 1/0 1.83 2.11 2.23 2231
A400-04AIAWG-600V 400 1/0 1.91 2.20 2.32 2469
A500-04AIAWG-600V 500 2/0 2.11 2.39 2.54 3028
A600-04AIAWG-600V 600 250 2.25 2.54 2.69 3166
A700-04AIAWG-600V 700 2/0 2.35 2.67 2.79 3591
A750-04AIAWG-600V 750 400 2.61 2.89 3.01 3886
A700-04AIAWG-600V 700 2/0 2.58 2.86 3.01 4043
A750-04AIAWG-600V 750 3/0 2.60 2.86 3.01 4300
A750-04AIAWG-600V 750 750 3.04 3.30 3.50 4998
A900-04AIAWG-600V 900 250 2.84 3.12 3.29 5087
A900-04AIAWG-600V 900 900 3.32 3.60 3.77 5844
Data is approximate and subject to normal manufacturing tolerances. For sizes not listed above please contact sales.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 238
Copyright © 2018, American Wire Group, Inc. 20141016
ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
UL Type MC Two Conductor Aluminum with Ground
PVC Jacket 2kV

Applications Flame retardant thermoset crosslinked polyeth-


MC Cable is approved for use in many applica- ylene (XLPE) insulation. Grounding is one bare-
tions including direct burial, use in cable tray aluminum alloy (AA-8000) compacted stranded
and outdoor exposure. The PVC jacket is free of conductor. Phase and grounding conductors are
harmful heavy metals in compliance with RoHS, cabled together with binder tape. Aluminum in-
Directive 2002/95/EC. terlocked armor, applied over the binder tape
• Run from the combiner box to the inverter and a longitudinal marker tape, for ID, when un-
• Suitable for rooftop solar applications jacketed. Black sunlight resistant and flame re-
• Outdoors tardant polyvinyl chloride (PVC) compound
• In wet locations (Type XHHW-2 , or RHW-2 jacket.
conductors)
• Direct buried Specifications
• Encased in concrete • Single conductors are rated XHHW-2 600V,
• Hazardous locations and CT Use 1/0AWG and larger. Additional UL
• Strong, but lightweight alloy armor resists Type PV available upon request.
damage • Aluminum armor is rated for Direct Burial,
• Suitable for wet locations, direct burial, en- using 6AWG and larger conductors, with over-
cased in concrete and other uses per the NEC all jacket
• More flexible than conduit • UL Type MC-HL available upon request of pur-
• Factory tested engineered product that pro- chaser where cable is approved for use in cer-
tects conductors from damage during installa- tain hazardous locations as permitted in
tion articles 501, 502, 503 and 504
• Meets or exceeds requirements of the NEC, as • UL 1569, Metal Clad Cables
well as applicable UL Standards. • UL 44, Rubber-Insulated wires and cables
• ICEA S-95-658 Standard for Non-shielded
Construction Power Cables Rated 2000 volts or less
Stranded aluminum alloy (AA8000) compacted
conductor, Class B stranding, perASTM B 801.

Item # Conductor Grounding Cable Cable Cable Cable


Size Conductor Diameter Diameter Diameter Weight

ARMORED CABLES
AWG/ AWG/ Under Armor Over Armor Over PVC (lb/MFT)
kcmil kcmil (in) (in) Jacket
(in)
A6-02AIA-WG-2KV 6 8 0.66 0.85 0.95 284.9
A4-02AIA-WG-2KV 4 6 0.75 0.94 1.04 351.1
A2-02AIA-WG-2KV 2 6 0.86 1.05 1.15 432.5
A1-02AIA-WG-2KV 1 4 1.00 1.19 1.29 540.6
A1/0-02AIA-WG-2KV 1/0 4 1.07 1.27 1.37 626.8
A2/0-02AIA-WG-2KV 2/0 4 1.15 1.35 1.45 709.0
A3/0-02AIA-WG-2KV 3/0 4 1.25 1.44 1.54 810.3
A4/0-02AIA-WG-2KV 4/0 2 1.35 1.61 1.73 1014.4
A250-02AIA-WG-2KV 250 2 1.50 1.76 1.88 1165.3
A300-02AIA-WG-2KV 300 2 1.60 1.86 1.98 1303.4
A350-02AIA-WG-2KV 350 2 1.69 1.95 2.07 1438.4
A400-02AIA-WG-2KV 400 1 1.78 2.04 2.16 1564.2
A500-02AIA-WG-2KV 500 1 1.93 2.19 2.31 1816.2
A750-02AIA-WG-2KV 750 1/0 2.34 2.59 2.74 2585.7
Data is approximate and subject to normal manufacturing tolerances. For sizes not listed above please contact sales.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 235
Copyright © 2018, American Wire Group, Inc. 20140921
NOTES
ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Type MC Three Conductor w/Ground
Aluminum Armor XHHW2 600V

Applications • UL 1569 for Metal-Clad Cables.


Type MC Cable is primarily used for services, • IEEE 1202 Flame Testing of Cables for Use in
feeders, and branch circuits as specified in the Cable Tray, in Industrial and Commercial Occu-
2011 National Electric Code. Type MC cable with pancies (70,000 BTU/hr).
Type XHHW2 conductors may be used in wet or • ICEA T29520 Vertical Cable Tray Flame Tests
dry locations at temperatures not to exceed (210,000 Btu/hr).
90°C. Used for power and lighting indoors, ex- • ICEA S66524 and requirements of the National
posed or concealed, in cable tray where identi- Electric Code
fied for such use in a raceway, or in dry • ICEA S95658 (NEMA WC 70) construction re-
locations and embedded in plaster or against quirements
other masonry. Voltage rating for XHHW2 con- • Federal Specification JC30B
ductors is 600V.
Color Code
Construction Three Phase Conductors (3): Black, red, white
Compact stranded AA-8000 series aluminum Ground Conductor (1): Green
conductor material per ASTM B800, ASTM B801, Other colors and stripes available by special
ASTM B836, ASTM B901 (Single Input Wire), as order.
applicable. A binder tape is wrapped over the For Special Order
conductors with interlocked aluminum tape ap- • The entire assembly can be covered with a
plied over the assembly. Rated 90°C wet or dry PVC or CPE outer jacket (black or color). Jack-
and is flame and sunlight resistant. XLPE insu- eted MC Cable may be used in wet locations,
lated XHHW2 conductors and insulated ground- either direct burial, in underground conduit,
ing conductor surrounded with aluminum or overhead.
armor (Metal Clad). • Halogen free jackets are available upon re-
Specifications quest
Type MC cable with Type XHHW2 conductors • A black jacket (on individual conductors) with
are manufactured and tested in accordance with color stripes can be requested.
the latest revisions of: • Bare Ground conductor available upon re-
quest.
• UL 44 for Thermoset-Insulated Wires and Ca- • For sizes not listed above please contact sales.
bles
• UL 83 for Thermoplastic-Insulated Wires and Ampacity
Cables To determine correct ampacity by conductor
• UL 1479 Standard for Fire Tests of Through- size, please consult the National Electric Code,

ARMORED CABLES
Penetration Firestops. latest edition.
• UL Classified 1, 2, and 3 Hour Through-Pene-
tration Firestop Systems.

IItem# Size of Cable Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable
Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight
Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT)
AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor
MCM (mils) AWG/MCM (mils)
A12-03MC12 12-12-12+12 12 3 91 30 12 91 30 366 640 93 119
A10-03MC10 10-10-10+10 10 3 116 30 10 116 30 425 699 116 147
A8-03MC10 8-8-8+10 8 3 134 45 10 116 30 528 801 149 198
A8-03MC8 8-8-8+8 8 3 134 45 8 134 45 543 817 157 212
A6-03MC8 6-6-6+8 6 3 169 45 8 134 45 618 892 196 258
A6-03MC6 6-6-6+6 6 3 169 45 6 169 45 626 900 206 271
A4-03MC6 4-4-4+6 4 3 213 45 6 169 45 720 994 264 339
A4-03MC4 4-4-4+4 4 3 213 45 4 213 45 732 1006 280 358
A3-03MC6 3-3-3+6 3 3 238 45 6 169 45 772 1045 302 382
A3-03MC4 3-3-3+4 3 3 238 45 4 213 45 795 1069 320 404
A3-03MC3 3-3-3+3 3 3 238 45 3 238 45 795 1069 330 415
A2-03MC6 2-2-2+6 2 3 268 45 6 169 45 843 1116 350 438
A2-03MC4 2-2-2+4 2 3 268 45 4 213 45 850 1124 366 456

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 911
Copyright © 2018, American Wire Group, Inc. 20180201
Type MC Three Conductor w/Ground
Aluminum Armor XHHW2 600V

Item# Size of Cable Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable
Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight
Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT)
AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor
MCM (mils) AWG/MCM (mils)
A2-03MC2 2-2-2+2 2 3 268 45 2 268 45 866 1140 391 485
A1-03MC4 1-1-1+4 1 3 299 55 4 213 45 961 1234 431 548
A1-03MC3 1-1-1+3 1 3 299 55 3 238 45 972 1246 443 562
A1-03MC2 1-1-1+2 1 3 299 55 2 268 45 972 1246 456 576
A1-03MC1 1-1-1+1 1 3 299 55 1 299 55 988 1262 474 603
A1/0-03MC4 1/0-1/0-1/0+4 1/2000 3 336 55 4 213 45 1028 1301 503 629
A1/0-03MC3 1/0-1/0-1/0+3 1/2000 3 336 55 3 238 45 1047 1321 516 644
A1/0-03MC2 1/0-1/0-1/0+2 1/2000 3 336 55 2 268 45 1063 1337 531 662
A1/0-03MC1 1/0-1/0-1/0+1 1/2000 3 336 55 1 299 55 1079 1352 549 689
A1/0-03MC1/0 1/0-1/0-1/0+1/0 1/2000 3 336 55 1/2000 336 55 1079 1352 569 712
A2/0-03MC4 2/0-2/0-2/0+4 2/2000 3 376 55 4 213 45 1118 1392 592 730
A2/0-03MC2 2/0-2/0-2/0+2 2/2000 3 376 55 2 268 45 1142 1415 618 760
A2/0-03MC1 2/0-2/0-2/0+1 2/2000 3 376 55 1 299 55 1157 1431 637 787
A2/0-03MC1/0 2/0-2/0-2/0+1/0 2/2000 3 376 55 1/2000 336 55 1177 1451 660 814
A2/0-03MC2/0 2/0-2/0-2/0+2/0 2/2000 3 376 55 2/2000 376 55 1177 1451 685 842
A3/0-03MC4 3/0-3/0-3/0+4 3/2000 3 421 55 4 213 45 1197 1470 700 850
A3/0-03MC2 3/0-3/0-3/0+2 3/2000 3 421 55 2 268 45 1220 1494 726 880
A3/0-03MC1 3/0-3/0-3/0+1 3/2000 3 421 55 1 299 55 1248 1522 747 909
A3/0-03MC1/0 3/0-3/0-3/0+1/0 3/2000 3 421 55 1/2000 336 55 1264 1537 769 935
A3/0-03MC2/0 3/0-3/0-3/0+2/0 3/2000 3 421 55 2/2000 376 55 1283 1557 798 967
A3/0-03MC3/0 3/0-3/0-3/0+3/0 3/2000 3 421 55 3/2000 421 55 1283 1557 830 1003
A4/0-03MC2 4/0-4/0-4/0+2 4/2000 3 476 55 2 268 45 1346 1620 866 1035
A4/0-03MC1 4/0-4/0-4/0+1 4/2000 3 476 55 1 299 55 1346 1620 882 1060
ARMORED CABLES

A4/0-03MC1/0 4/0-4/0-4/0+1/0 4/2000 3 476 55 1/2000 336 55 1378 1652 907 1088
A4/0-03MC2/0 4/0-4/0-4/0+2/0 4/2000 3 476 55 2/2000 376 55 1394 1667 935 1119
A4/0-03MC3/0 4/0-4/0-4/0+3/0 4/2000 3 476 55 3/2000 421 55 1417 1691 970 1159
A4/0-03MC4/0 4/0-4/0-4/0+4/0 4/2000 3 476 55 4/2000 476 55 1417 1691 1010 1204
A250-03MC2 250-250-250+2 250 3 520 65 2 268 45 1461 1734 993 1203
A250-03MC1 250-250-250+1 250 3 520 65 1 299 55 1496 1820 1065 1284
A250-03MC1/0 250-250-250+1/0 250 3 520 65 1/2000 336 55 1496 1820 1086 1308
A250-03MC2/0 250-250-250+2/0 250 3 520 65 2/2000 376 55 1528 1851 1116 1342
A250-03MC3/0 250-250-250+3/0 250 3 520 65 3/2000 421 55 1547 1871 1152 1382
A250-03MC4/0 250-250-250+4/0 250 3 520 65 4/2000 476 55 1575 1898 1197 1432
A250-03MC250 250-250-250+250 250 3 520 65 250 520 65 1575 1898 1234 1482
A300-03MC2 300-300-300+2 300 3 571 65 2 268 45 1579 1902 1201 1428
A300-03MC1 300-300-300+1 300 3 571 65 1 299 55 1579 1902 1217 1452
A300-03MC1/0 300-300-300+1/0 300 3 571 65 1/2000 336 55 1614 1938 1244 1483
A300-03MC2/0 300-300-300+2/0 300 3 571 65 2/2000 376 55 1614 1938 1269 1511
A300-03MC3/0 300-300-300+3/0 300 3 571 65 3/2000 421 55 1650 1973 1308 1554
A300-03MC4/0 300-300-300+4/0 300 3 571 65 4/2000 476 55 1669 1993 1351 1602
A300-03MC250 300-300-300+250 300 3 571 65 250 520 65 1697 2020 1393 1657
A300-03MC300 300-300-300+300 300 3 571 65 300 571 65 1697 2020 1438 1708
A350-03MC2 350-350-350+2 350 3 614 65 2 268 45 1638 1961 1348 1589
A350-03MC1 350-350-350+1 350 3 614 65 1 299 55 1673 1997 1371 1620
A350-03MC1/0 350-350-350+1/0 350 3 614 65 1/2000 336 55 1673 1997 1391 1643

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
911 Information on this sheet subject to change without notice.
20180201 Copyright © 2018, American Wire Group, Inc.
Type MC Three Conductor w/Ground
Aluminum Armor XHHW2 600V

Item# Size of Cable Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable
Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight
Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT)
AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor
MCM (mils) AWG/MCM (mils)
A350-03MC2/0 350-350-350+2/0 350 3 614 65 2/2000 376 55 1713 2036 1424 1680
A350-03MC3/0 350-350-350+3/0 350 3 614 65 3/2000 421 55 1748 2072 1462 1722
A350-03MC4/0 350-350-350+4/0 350 3 614 65 4/2000 476 55 1748 2072 1502 1767
A350-03MC250 350-350-350+250 350 3 614 65 250 520 65 1772 2095 1543 1821
A350-03MC300 350-350-350+300 350 3 614 65 300 571 65 1799 2123 1593 1877
A350-03MC350 350-350-350+350 350 3 614 65 350 614 65 1799 2123 1639 1927
A400-03MC1 400-400-400+1 400 3 657 65 1 299 55 1772 2095 1531 1794
A400-03MC1/0 400-400-400+1/0 400 3 657 65 1/2000 336 55 1772 2095 1551 1817
A400-03MC2/0 400-400-400+2/0 400 3 657 65 2/2000 376 55 1811 2135 1584 1854
A400-03MC3/0 400-400-400+3/0 400 3 657 65 3/2000 421 55 1811 2135 1616 1890
A400-03MC4/0 400-400-400+4/0 400 3 657 65 4/2000 476 55 1850 2174 1663 1942
A400-03MC250 400-400-400+250 400 3 657 65 250 520 65 1874 2198 1704 1996
A400-03MC300 400-400-400+300 400 3 657 65 300 571 65 1874 2198 1749 2047
A400-03MC350 400-400-400+350 400 3 657 65 350 614 65 1906 2229 1800 2103
A400-03MC400 400-400-400+400 400 3 657 65 400 657 65 1906 2229 1848 2154
A450-03MC1 450-450-450+1 450 3 701 65 1 299 55 1827 2150 1677 1954
A450-03MC1/0 450-450-450+1/0 450 3 701 65 1/2000 336 55 1870 2194 1706 1986
A450-03MC2/0 450-450-450+2/0 450 3 701 65 2/2000 376 55 1870 2194 1731 2014
A450-03MC3/0 450-450-450+3/0 450 3 701 65 3/2000 421 55 1913 2237 1771 2059
A450-03MC4/0 450-450-450+4/0 450 3 701 65 4/2000 476 55 1953 2276 1818 2111
A450-03MC250 450-450-450+250 450 3 701 65 250 520 65 1953 2276 1855 2161
A450-03MC300 450-450-450+300 450 3 701 65 300 571 65 1976 2300 1904 2216
A450-03MC350 450-450-450+350 450 3 701 65 350 614 65 1976 2300 1950 2266

ARMORED CABLES
A450-03MC400 450-450-450+400 450 3 701 65 400 657 65 2012 2335 2004 2324
A450-03MC450 450-450-450+450 450 3 701 65 450 701 65 2012 2335 2049 2374
A500-03MC1 500-500-500+1 500 3 736 65 1 299 55 1906 2229 1828 2116
A500-03MC1/0 500-500-500+1/0 500 3 736 65 1/2000 336 55 1949 2272 1857 2148
A500-03MC2/0 500-500-500+2/0 500 3 736 65 2/2000 376 55 1949 2272 1882 2177
A500-03MC3/0 500-500-500+3/0 500 3 736 65 3/2000 421 55 1992 2316 1922 2221
A500-03MC4/0 500-500-500+4/0 500 3 736 65 4/2000 476 55 1992 2316 1962 2266
A500-03MC250 500-500-500+250 500 3 736 65 250 520 65 2035 2359 2006 2324
A500-03MC300 500-500-500+300 500 3 736 65 300 571 65 2063 2387 2057 2380
A500-03MC350 500-500-500+350 500 3 736 65 350 614 65 2063 2387 2102 2430
A500-03MC400 500-500-500+400 500 3 736 65 400 657 65 2094 2418 2155 2487
A500-03MC450 500-500-500+450 500 3 736 65 450 701 65 2094 2418 2201 2537
A500-03MC500 500-500-500+500 500 3 736 65 500 736 65 2094 2418 2246 2586
A600-03MC1 600-600-600+1 600 3 815 80 1 299 55 2106 2430 2144 2524
A600-03MC1/0 600-600-600+1/0 600 3 815 80 1/2000 336 55 2106 2430 2164 2547
A600-03MC2/0 600-600-600+2/0 600 3 815 80 2/2000 376 55 2146 2469 2197 2583
A600-03MC3/0 600-600-600+3/0 600 3 815 80 3/2000 421 55 2193 2517 2238 2629
A600-03MC4/0 600-600-600+4/0 600 3 815 80 4/2000 476 55 2244 2568 2287 2683
A600-03MC250 600-600-600+250 600 3 815 80 250 520 65 2244 2568 2323 2733
A600-03MC300 600-600-600+300 600 3 815 80 300 571 65 2291 2615 2378 2793
A600-03MC350 600-600-600+350 600 3 815 80 350 614 65 2291 2615 2423 2842
A600-03MC400 600-600-600+400 600 3 815 80 400 657 65 2323 2646 2476 2900

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 911
Copyright © 2018, American Wire Group, Inc. 20180201
Type MC Three Conductor w/Ground
Aluminum Armor XHHW2 600V

Item# Size of Cable Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable
Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight
Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT)
AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor
MCM (mils) AWG/MCM (mils)
A600-03MC450 600-600-600+450 600 3 815 80 450 701 65 2323 2646 2521 2950
A600-03MC500 600-600-600+500 600 3 815 80 500 736 65 2323 2646 2567 2999
A600-03MC600 600-600-600+600 600 3 815 80 600 815 80 2358 2682 2666 3129
A650-03MC1 650-650-650+1 650 3 843 80 1 299 55 2165 2489 2291 2682
A650-03MC1/0 650-650-650+1/0 650 3 843 80 1/2000 336 55 2165 2489 2311 2705
A650-03MC2/0 650-650-650+2/0 650 3 843 80 2/2000 376 55 2209 2532 2345 2742
A650-03MC3/0 650-650-650+3/0 650 3 843 80 3/2000 421 55 2256 2580 2386 2787
A650-03MC4/0 650-650-650+4/0 650 3 843 80 4/2000 476 55 2256 2580 2425 2832
A650-03MC250 650-650-650+250 650 3 843 80 250 520 65 2307 2631 2471 2892
A650-03MC300 650-650-650+300 650 3 843 80 300 571 65 2307 2631 2517 2942
A650-03MC350 650-650-650+350 650 3 843 80 350 614 65 2358 2682 2572 3002
A650-03MC400 650-650-650+400 650 3 843 80 400 657 65 2358 2682 2619 3054
A650-03MC450 650-650-650+450 650 3 843 80 450 701 65 2386 2709 2669 3109
A650-03MC500 650-650-650+500 650 3 843 80 500 736 65 2386 2709 2715 3158
A650-03MC600 650-650-650+600 650 3 843 80 600 815 80 2429 2753 2816 3289
A650-03MC650 650-650-650+650 650 3 843 80 650 843 80 2429 2753 2861 3338
A700-03MC1 700-700-700+1 700 3 878 80 1 299 55 2244 2568 2448 2852
A700-03MC1/0 700-700-700+1/0 700 3 878 80 1/2000 336 55 2244 2568 2468 2875
A700-03MC2/0 700-700-700+2/0 700 3 878 80 2/2000 376 55 2244 2568 2493 2904
A700-03MC3/0 700-700-700+3/0 700 3 878 80 3/2000 421 55 2335 2658 2542 2957
A700-03MC4/0 700-700-700+4/0 700 3 878 80 4/2000 476 55 2335 2658 2582 3002
A700-03MC250 700-700-700+250 700 3 878 80 250 520 65 2390 2713 2628 3063
A700-03MC300 700-700-700+300 700 3 878 80 300 571 65 2390 2713 2674 3113
ARMORED CABLES

A700-03MC350 700-700-700+350 700 3 878 80 350 614 65 2441 2765 2729 3173
A700-03MC400 700-700-700+400 700 3 878 80 400 657 65 2441 2765 2776 3225
A700-03MC450 700-700-700+450 700 3 878 80 450 701 65 2472 2796 2827 3280
A700-03MC500 700-700-700+500 700 3 878 80 500 736 65 2472 2796 2873 3329
A700-03MC600 700-700-700+600 700 3 878 80 600 815 80 2512 2835 2973 3460
A700-03MC700 700-700-700+700 700 3 878 80 700 878 80 2512 2835 3065 3560
A750-03MC1/0 750-750-750+1/0 750 3 909 80 1/2000 336 55 2307 2631 2616 3036
A750-03MC2/0 750-750-750+2/0 750 3 909 80 2/2000 376 55 2307 2631 2641 3064
A750-03MC3/0 750-750-750+3/0 750 3 909 80 3/2000 421 55 2350 2674 2681 3108
A750-03MC4/0 750-750-750+4/0 750 3 909 80 4/2000 476 55 2406 2729 2731 3164
A750-03MC250 750-750-750+250 750 3 909 80 250 520 65 2457 2780 2777 3224
A750-03MC300 750-750-750+300 750 3 909 80 300 571 65 2457 2780 2822 3274
A750-03MC350 750-750-750+350 750 3 909 80 350 614 65 2457 2780 2868 3324
A750-03MC400 750-750-750+400 750 3 909 80 400 657 65 2512 2835 2925 3386
A750-03MC450 750-750-750+450 750 3 909 80 450 701 65 2512 2835 2971 3436
A750-03MC500 750-750-750+500 750 3 909 80 500 736 65 2543 2867 3022 3491
A750-03MC600 750-750-750+600 750 3 909 80 600 815 80 2587 2910 3123 3622
A750-03MC700 750-750-750+700 750 3 909 80 700 878 80 2587 2910 3215 3723
A750-03MC750 750-750-750+750 750 3 909 80 750 909 80 2587 2910 3261 3772
A800-03MC1/0 800-800-800+1/0 800 3 937 80 1/2000 336 55 2370 2694 2764 3194
A800-03MC2/0 800-800-800+2/0 800 3 937 80 2/2000 376 55 2370 2694 2789 3223
A800-03MC3/0 800-800-800+3/0 800 3 937 80 3/2000 421 55 2413 2737 2829 3267

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
911 Information on this sheet subject to change without notice.
20180201 Copyright © 2018, American Wire Group, Inc.
Type MC Three Conductor w/Ground
Aluminum Armor XHHW2 600V

Item# Size of Cable Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable
Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight
Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT)
AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor
MCM (mils) AWG/MCM (mils)
A800-03MC4/0 800-800-800+4/0 800 3 937 80 4/2000 476 55 2469 2792 2879 3323
A800-03MC250 800-800-800+250 800 3 937 80 250 520 65 2469 2792 2916 3372
A800-03MC300 800-800-800+300 800 3 937 80 300 571 65 2524 2847 2971 3434
A800-03MC350 800-800-800+350 800 3 937 80 350 614 65 2524 2847 3017 3483
A800-03MC400 800-800-800+400 800 3 937 80 400 657 65 2579 2902 3074 3546
A800-03MC450 800-800-800+450 800 3 937 80 450 701 65 2579 2902 3120 3595
A800-03MC500 800-800-800+500 800 3 937 80 500 736 65 2579 2902 3165 3644
A800-03MC600 800-800-800+600 800 3 937 80 600 815 80 2610 2934 3264 3773
A800-03MC700 800-800-800+700 800 3 937 80 700 878 80 2654 2977 3364 3882
A800-03MC750 800-800-800+750 800 3 937 80 750 909 80 2654 2977 3410 3931
A800-03MC800 800-800-800+800 800 3 937 80 800 937 80 2654 2977 3455 3980
A900-03MC2/0 900-900-900+2/0 900 3 1000 80 2/2000 376 55 2504 2828 3092 3550
A900-03MC3/0 900-900-900+3/0 900 3 1000 80 3/2000 421 55 2504 2828 3124 3586
A900-03MC4/0 900-900-900+4/0 900 3 1000 80 4/2000 476 55 2610 2934 3184 3652
A900-03MC250 900-900-900+250 900 3 1000 80 250 520 65 2610 2934 3220 3701
A900-03MC300 900-900-900+300 900 3 1000 80 300 571 65 2669 2993 3276 3763
A900-03MC350 900-900-900+350 900 3 1000 80 350 614 65 2669 2993 3322 3813
A900-03MC400 900-900-900+400 900 3 1000 80 400 657 65 2669 2993 3369 3865
A900-03MC450 900-900-900+450 900 3 1000 80 450 701 65 2724 3048 3425 3925
A900-03MC500 900-900-900+500 900 3 1000 80 500 736 65 2724 3048 3470 3974
A900-03MC600 900-900-900+600 900 3 1000 80 600 815 80 2760 3083 3569 4104
A900-03MC700 900-900-900+700 900 3 1000 80 700 878 80 2760 3083 3662 4204
A900-03MC750 900-900-900+750 900 3 1000 80 750 909 80 2807 3131 3716 4263

ARMORED CABLES
A900-03MC800 900-900-900+800 900 3 1000 80 800 937 80 2807 3131 3762 4312
A900-03MC900 900-900-900+900 900 3 1000 80 900 1000 80 2807 3131 3854 4412
A900-03MC1000 900-900-900+1000 900 3 1000 80 1000 1059 80 2807 3131 3947 4512
A1000-03MC2/0 1000-1000-1000+2/0 1000 3 1059 80 2/2000 376 55 2634 2957 3394 3875
A1000-03MC3/0 1000-1000-1000+3/0 1000 3 1059 80 3/2000 421 55 2634 2957 3426 3911
A1000-03MC4/0 1000-1000-1000+4/0 1000 3 1059 80 4/2000 476 55 2681 3005 3475 3965
A1000-03MC250 1000-1000-1000+250 1000 3 1059 80 250 520 65 2744 3068 3523 4027
A1000-03MC300 1000-1000-1000+300 1000 3 1059 80 300 571 65 2744 3068 3568 4078
A1000-03MC350 1000-1000-1000+350 1000 3 1059 80 350 614 65 2803 3127 3625 4139
A1000-03MC400 1000-1000-1000+400 1000 3 1059 80 400 657 65 2803 3127 3672 4191
A1000-03MC450 1000-1000-1000+450 1000 3 1059 80 450 701 65 2803 3127 3717 4240
A1000-03MC500 1000-1000-1000+500 1000 3 1059 80 500 736 65 2866 3190 3775 4302
A1000-03MC600 1000-1000-1000+600 1000 3 1059 80 600 815 80 2902 3225 3874 4431
A1000-03MC650 1000-1000-1000+650 1000 3 1059 80 650 843 80 2902 3225 3919 4480
A1000-03MC700 1000-1000-1000+700 1000 3 1059 80 700 878 80 2902 3225 3966 4532
A1000-03MC750 1000-1000-1000+750 1000 3 1059 80 750 909 80 2902 3225 4012 4581
A1000-03MC800 1000-1000-1000+800 1000 3 1059 80 800 937 80 2902 3225 4057 4630
A1000-03MC900 1000-1000-1000+900 1000 3 1059 80 900 1000 80 2949 3272 4159 4739
A1000-03MC1000 1000-1000-1000+1000 1000 3 1059 80 1000 1059 80 2949 3272 4251 4839

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 911
Copyright © 2018, American Wire Group, Inc. 20180201
NOTES
ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Type MC Four Conductor w/Ground
Aluminum Armor XHHW-2 600V

Applications • UL 1569 for Metal Clad Cables.


Type MC Cable is primarily used for services, • IEEE 1202 Flame Testing of Cables for Use in
feeders, and branch circuits as specified in the Cable Tray, in Industrial and Commercial Occu-
2011 National Electric Code. Type MC cable with pancies (70,000 BTU/hr).
Type XHHW2 conductors may be used in wet or • ICEA T29520 Vertical Cable Tray Flame Tests
dry locations at temperatures not to exceed (210,000 Btu/hr).
90°C. Used for power and lighting indoors, ex- • ICEA S66524 and requirements of the National
posed or concealed, in cable tray where identi- Electric Code
fied for such use; in a raceway, or in dry • ICEA S95658 (NEMA WC 70) construction re-
locations and embedded in plaster or against quirements
other masonry. Voltage rating for XHHW2 con- • Federal Specification JC30B
ductors is 600V.
Color Code
Construction Four Phase Conductors (4): Black, red, blue,
Compact stranded AA8000 series aluminum white
conductor material per ASTM B800, ASTM B801, Grounding Conductor (1): Green
ASTM B836, ASTM B901 (Single Input Wire), as Other colors and stripes available by special
applicable. A binder tape is wrapped over the order.
conductors with interlocked aluminum tape ap-
plied over the assembly. Rated 90°C wet or dry For Special Order
and is flame and sunlight resistant. XLPE insu- • The entire assembly can be covered with a
lated XHHW2 conductors and insulated ground- PVC or CPE outer jacket (black or color). Jack-
ing conductor surrounded with aluminum eted MC Cable may be used in wet locations,
armor (Metal Clad). either direct burial, in underground conduit,
or overhead.
Specifications • Halogen free jackets are available upon re-
Type MC cable with Type XHHW2 conductors quest
are manufactured and tested in accordance with • A black jacket (on individual conductors) with
the latest revisions of: color stripes can be requested.
• UL 44 for Thermoset Insulated Wires and Ca- • Bare Ground conductor available upon re-
bles quest.
• UL 83 for Thermoplastic Insulated Wires and • For sizes not listed above please contact sales.
Cables Ampacity
• UL 1479 Standard for Fire Tests of Through To determine correct ampacity by conductor

ARMORED CABLES
Penetration Firestops. size, please consult the National Electric Code,
• UL Classified 1, 2, and 3 Hour Through Pene- latest edition.
tration Firestop Systems.

Item# Size of Cable Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable
Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight
Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT)
AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor
MCM (mils) AWG/MCM (mils)
A10-04MC10 10-10-10-10+10 10 4 116 30 10 116 30 476 750 134 172
A8-04MC10 8-8-8-8+10 8 4 134 45 10 116 30 583 856 173 234
A8-04MC8 8-8-8-8+8 8 4 134 45 8 134 45 606 880 182 250
A6-04MC8 6-6-6-6+8 6 4 169 45 8 134 45 685 959 230 308
A6-04MC6 6-6-6-6+6 6 4 169 45 6 169 45 701 974 242 322
A4-04MC6 4-4-4-4+6 4 4 213 45 6 169 45 803 1077 315 409
A4-04MC4 4-4-4-4+4 4 4 213 45 4 213 45 819 1093 332 429
A3-04MC6 3-3-3-3+6 3 4 238 45 6 169 45 854 1128 363 464
A3-04MC4 3-3-3-3+4 3 4 238 45 4 213 45 886 1159 382 487
A3-04MC3 3-3-3-3+3 3 4 238 45 3 238 45 886 1159 392 498
A2-04MC6 2-2-2-2+6 2 4 268 45 6 169 45 929 1203 425 535
A2-04MC4 2-2-2-2+4 2 4 268 45 4 213 45 949 1222 442 555

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 912
Copyright © 2018, American Wire Group, Inc. 20180201
Type MC Four Conductor w/Ground
Aluminum Armor XHHW-2 600V

Item# Size of Cable Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable
Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight
Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT)
AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor
MCM (mils) AWG/MCM (mils)
A2-04MC2 2-2-2-2+2 2 4 268 45 2 268 45 965 1238 467 584
A1-04MC4 1-1-1-1+4 1 4 299 55 4 213 45 1063 1337 524 672
A1-04MC3 1-1-1-1+3 1 4 299 55 3 238 45 1083 1356 537 687
A1-04MC2 1-1-1-1+2 1 4 299 55 2 268 45 1083 1356 550 701
A1-04MC1 1-1-1-1+1 1 4 299 55 1 299 55 1106 1380 569 730
A1/0-04MC4 1/0-1/0-1/0-1/0+4 1/0 4 336 55 4 213 45 1138 1411 617 778
A1/0-04MC3 1/0-1/0-1/0-1/0+3 1/0 4 336 55 3 238 45 1161 1435 631 794
A1/0-04MC2 1/0-1/0-1/0-1/0+2 1/0 4 336 55 2 268 45 1181 1455 647 812
A1/0-04MC1 1/0-1/0-1/0-1/0+1 1/0 4 336 55 1 299 55 1205 1478 666 840
A1/0-04MC1/0 1/0-1/0-1/0-1/0+1/0 1/0 4 336 55 1/0 336 55 1205 1478 686 863
A2/0-04MC4 2/0-2/0-2/0-2/0+4 2/0 4 376 55 4 213 45 1240 1514 733 909
A2/0-04MC2 2/0-2/0-2/0-2/0+2 2/0 4 376 55 2 268 45 1264 1537 760 939
A2/0-04MC1 2/0-2/0-2/0-2/0+1 2/0 4 376 55 1 299 55 1287 1561 779 968
A2/0-04MC1/0 2/0-2/0-2/0-2/0+1/0 2/0 4 376 55 1/0 336 55 1311 1585 803 995
A2/0-04MC2/0 2/0-2/0-2/0-2/0+2/0 2/0 4 376 55 2/0 376 55 1311 1585 828 1023
A3/0-04MC4 3/0-3/0-3/0-3/0+4 3/0 4 421 55 4 213 45 1327 1600 875 1066
A3/0-04MC2 3/0-3/0-3/0-3/0+2 3/0 4 421 55 2 268 45 1354 1628 902 1097
A3/0-04MC1 3/0-3/0-3/0-3/0+1 3/0 4 421 55 1 299 55 1382 1656 922 1126
A3/0-04MC1/0 3/0-3/0-3/0-3/0+1/0 3/0 4 421 55 1/0 336 55 1406 1679 946 1154
A3/0-04MC2/0 3/0-3/0-3/0-3/0+2/0 3/0 4 421 55 2/0 376 55 1433 1707 975 1187
A3/0-04MC3/0 3/0-3/0-3/0-3/0+3/0 3/0 4 421 55 3/0 421 55 1433 1707 1007 1223
A4/0-04MC2 4/0-4/0-4/0-4/0+2 4/0 4 476 55 2 268 45 1492 1816 1134 1350
A4/0-04MC1 4/0-4/0-4/0-4/0+1 4/0 4 476 55 1 299 55 1492 1816 1150 1374
ARMORED CABLES

A4/0-04MC1/0 4/0-4/0-4/0-4/0+1/0 4/0 4 476 55 1/0 336 55 1524 1847 1176 1404
A4/0-04MC2/0 4/0-4/0-4/0-4/0+2/0 4/0 4 476 55 2/0 376 55 1551 1875 1206 1438
A4/0-04MC3/0 4/0-4/0-4/0-4/0+3/0 4/0 4 476 55 3/0 421 55 1583 1906 1244 1479
A4/0-04MC4/0 4/0-4/0-4/0-4/0+4/0 4/0 4 476 55 4/0 476 55 1583 1906 1284 1524
A250-04MC2 250-250-250-250+2 250 4 520 65 2 268 45 1626 1950 1304 1575
A250-04MC1 250-250-250-250+1 250 4 520 65 1 299 55 1657 1981 1326 1605
A250-04MC1/0 250-250-250-250+1/0 250 4 520 65 1/0 336 55 1657 1981 1346 1629
A250-04MC2/0 250-250-250-250+2/0 250 4 520 65 2/0 376 55 1689 2013 1377 1664
A250-04MC3/0 250-250-250-250+3/0 250 4 520 65 3/0 421 55 1724 2048 1416 1706
A250-04MC4/0 250-250-250-250+4/0 250 4 520 65 4/0 476 55 1756 2080 1462 1757
A250-04MC250 250-250-250-250+250 250 4 520 65 250 520 65 1756 2080 1498 1807
A300-04MC2 300-300-300-300+2 300 4 571 65 2 268 45 1752 2076 1509 1802
A300-04MC1 300-300-300-300+1 300 4 571 65 1 299 55 1752 2076 1525 1826
A300-04MC1/0 300-300-300-300+1/0 300 4 571 65 1/0 336 55 1787 2111 1552 1856
A300-04MC2/0 300-300-300-300+2/0 300 4 571 65 2/0 376 55 1787 2111 1577 1885
A300-04MC3/0 300-300-300-300+3/0 300 4 571 65 3/0 421 55 1823 2146 1616 1928
A300-04MC4/0 300-300-300-300+4/0 300 4 571 65 4/0 476 55 1858 2182 1663 1979
A300-04MC250 300-300-300-300+250 300 4 571 65 250 520 65 1894 2217 1706 2036
A300-04MC300 300-300-300-300+300 300 4 571 65 300 571 65 1894 2217 1751 2086
A350-04MC2 350-350-350-350+2 350 4 614 65 2 268 45 1846 2170 1709 2019
A350-04MC1 350-350-350-350+1 350 4 614 65 1 299 55 1862 2186 1728 2047
A350-04MC1/0 350-350-350-350+1/0 350 4 614 65 1/0 336 55 1862 2186 1748 2070

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
912 Information on this sheet subject to change without notice.
20180201 Copyright © 2018, American Wire Group, Inc.
Type MC Four Conductor w/Ground
Aluminum Armor XHHW-2 600V

Item# Size of Cable Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable
Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight
Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT)
AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor
MCM (mils) AWG/MCM (mils)
A350-04MC2/0 350-350-350-350+2/0 350 4 614 65 2/0 376 55 1898 2221 1780 2105
A350-04MC3/0 350-350-350-350+3/0 350 4 614 65 3/0 421 55 1933 2257 1818 2148
A350-04MC4/0 350-350-350-350+4/0 350 4 614 65 4/0 476 55 1933 2257 1858 2193
A350-04MC250 350-350-350-350+250 350 4 614 65 250 520 65 1972 2296 1902 2250
A350-04MC300 350-350-350-350+300 350 4 614 65 300 571 65 2008 2331 1954 2308
A350-04MC350 350-350-350-350+350 350 4 614 65 350 614 65 2008 2331 1999 2357
A400-04MC1 400-400-400-400+1 400 4 657 65 1 299 55 1969 2292 1936 2274
A400-04MC1/0 400-400-400-400+1/0 400 4 657 65 1/0 336 55 1969 2292 1957 2297
A400-04MC2/0 400-400-400-400+2/0 400 4 657 65 2/0 376 55 2008 2331 1989 2333
A400-04MC3/0 400-400-400-400+3/0 400 4 657 65 3/0 421 55 2008 2331 2021 2369
A400-04MC4/0 400-400-400-400+4/0 400 4 657 65 4/0 476 55 2047 2371 2069 2422
A400-04MC250 400-400-400-400+250 400 4 657 65 250 520 65 2087 2410 2112 2479
A400-04MC300 400-400-400-400+300 400 4 657 65 300 571 65 2087 2410 2158 2529
A400-04MC350 400-400-400-400+350 400 4 657 65 350 614 65 2102 2426 2206 2582
A400-04MC400 400-400-400-400+400 400 4 657 65 400 657 65 2126 2450 2258 2639
A450-04MC1 450-450-450-450+1 450 4 701 65 1 299 55 2063 2387 2136 2491
A450-04MC1/0 450-450-450-450+1/0 450 4 701 65 1/0 336 55 2079 2402 2159 2518
A450-04MC2/0 450-450-450-450+2/0 450 4 701 65 2/0 376 55 2079 2402 2184 2546
A450-04MC3/0 450-450-450-450+3/0 450 4 701 65 3/0 421 55 2118 2442 2223 2590
A450-04MC4/0 450-450-450-450+4/0 450 4 701 65 4/0 476 55 2161 2485 2271 2643
A450-04MC250 450-450-450-450+250 450 4 701 65 250 520 65 2161 2485 2308 2693
A450-04MC300 450-450-450-450+300 450 4 701 65 300 571 65 2201 2524 2360 2751
A450-04MC400 450-450-450-450+400 450 4 701 65 400 657 65 2244 2568 2461 2861

ARMORED CABLES
A450-04MC450 450-450-450-450+450 450 4 701 65 450 701 65 2244 2568 2507 2910
A500-04MC1 500-500-500-500+1 500 4 736 65 1 299 55 2150 2473 2333 2704
A500-04MC1/0 500-500-500-500+1/0 500 4 736 65 1/0 336 55 2165 2489 2357 2731
A500-04MC2/0 500-500-500-500+2/0 500 4 736 65 2/0 376 55 2165 2489 2382 2759
A500-04MC3/0 500-500-500-500+3/0 500 4 736 65 3/0 421 55 2209 2532 2422 2803
A500-04MC4/0 500-500-500-500+4/0 500 4 736 65 4/0 476 55 2209 2532 2462 2848
A500-04MC250 500-500-500-500+250 500 4 736 65 250 520 65 2252 2576 2506 2906
A500-04MC300 500-500-500-500+300 500 4 736 65 300 571 65 2295 2619 2560 2965
A500-04MC350 500-500-500-500+350 500 4 736 65 350 614 65 2295 2619 2605 3015
A500-04MC400 500-500-500-500+400 500 4 736 65 400 657 65 2339 2662 2661 3075
A500-04MC450 500-500-500-500+450 500 4 736 65 450 701 65 2339 2662 2706 3125
A500-04MC500 500-500-500-500+500 500 4 736 65 500 736 65 2339 2662 2751 3174
A600-04MC1 600-600-600-600+1 600 4 815 80 1 299 55 2358 2682 2743 3236
A600-04MC1/0 600-600-600-600+1/0 600 4 815 80 1/0 336 55 2417 2741 2775 3271
A600-04MC2/0 600-600-600-600+2/0 600 4 815 80 2/0 376 55 2417 2741 2800 3299
A600-04MC3/0 600-600-600-600+3/0 600 4 815 80 3/0 421 55 2437 2761 2835 3339
A600-04MC4/0 600-600-600-600+4/0 600 4 815 80 4/0 476 55 2488 2812 2885 3394
A600-04MC250 600-600-600-600+250 600 4 815 80 250 520 65 2488 2812 2921 3443
A600-04MC300 600-600-600-600+300 600 4 815 80 300 571 65 2535 2859 2975 3503
A600-04MC350 600-600-600-600+350 600 4 815 80 350 614 65 2535 2859 3021 3553
A600-04MC400 600-600-600-600+400 600 4 815 80 400 657 65 2583 2906 3077 3614
A600-04MC450 600-600-600-600+450 600 4 815 80 450 701 65 2583 2906 3122 3663

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 912
Copyright © 2018, American Wire Group, Inc. 20180201
Type MC Four Conductor w/Ground
Aluminum Armor XHHW-2 600V

Item# Size of Cable Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable
Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight
Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT)
AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor
MCM (mils) AWG/MCM (mils)
A600-04MC500 600-600-600-600+500 600 4 815 80 500 736 65 2583 2906 3168 3712
A600-04MC600 600-600-600-600+600 600 4 815 80 600 815 80 2634 2957 3270 3845
A650-04MC1 650-650-650-650+1 650 4 843 80 1 299 55 2429 2753 2938 3445
A650-04MC1/0 650-650-650-650+1/0 650 4 843 80 1/0 336 55 2488 2812 2969 3480
A650-04MC2/0 650-650-650-650+2/0 650 4 843 80 2/0 376 55 2488 2812 2994 3508
A650-04MC3/0 650-650-650-650+3/0 650 4 843 80 3/0 421 55 2508 2831 3030 3548
A650-04MC4/0 650-650-650-650+4/0 650 4 843 80 4/0 476 55 2508 2831 3070 3592
A650-04MC250 650-650-650-650+250 650 4 843 80 250 520 65 2559 2883 3116 3652
A650-04MC300 650-650-650-650+300 650 4 843 80 300 571 65 2559 2883 3161 3703
A650-04MC350 650-650-650-650+350 650 4 843 80 350 614 65 2606 2930 3216 3762
A650-04MC400 650-650-650-650+400 650 4 843 80 400 657 65 2606 2930 3263 3813
A650-04MC450 650-650-650-650+450 650 4 843 80 450 701 65 2657 2981 3318 3873
A650-04MC500 650-650-650-650+500 650 4 843 80 500 736 65 2657 2981 3363 3922
A650-04MC600 650-650-650-650+600 650 4 843 80 600 815 80 2709 3032 3465 4055
A650-04MC650 650-650-650-650+650 650 4 843 80 650 843 80 2709 3032 3511 4104
A700-04MC1 700-700-700-700+1 700 4 878 80 1 299 55 2512 2835 3142 3667
A700-04MC1/0 700-700-700-700+1/0 700 4 878 80 1/0 336 55 2575 2898 3174 3703
A700-04MC2/0 700-700-700-700+2/0 700 4 878 80 2/0 376 55 2575 2898 3199 3732
A700-04MC3/0 700-700-700-700+3/0 700 4 878 80 3/0 421 55 2594 2918 3235 3771
A700-04MC4/0 700-700-700-700+4/0 700 4 878 80 4/0 476 55 2594 2918 3275 3816
A700-04MC250 700-700-700-700+250 700 4 878 80 250 520 65 2646 2969 3321 3876
A700-04MC300 700-700-700-700+300 700 4 878 80 300 571 65 2646 2969 3366 3926
A700-04MC350 700-700-700-700+350 700 4 878 80 350 614 65 2701 3024 3422 3987
ARMORED CABLES

A700-04MC400 700-700-700-700+400 700 4 878 80 400 657 65 2701 3024 3469 4038
A700-04MC450 700-700-700-700+450 700 4 878 80 450 701 65 2752 3076 3524 4098
A700-04MC500 700-700-700-700+500 700 4 878 80 500 736 65 2752 3076 3570 4147
A700-04MC600 700-700-700-700+600 700 4 878 80 600 815 80 2803 3127 3672 4280
A700-04MC700 700-700-700-700+700 700 4 878 80 700 878 80 2803 3127 3765 4380
A750-04MC1/0 750-750-750-750+1/0 750 4 909 80 1/0 336 55 2587 2910 3358 3903
A750-04MC2/0 750-750-750-750+2/0 750 4 909 80 2/0 376 55 2650 2973 3395 3943
A750-04MC3/0 750-750-750-750+3/0 750 4 909 80 3/0 421 55 2650 2973 3427 3979
A750-04MC4/0 750-750-750-750+4/0 750 4 909 80 4/0 476 55 2673 2997 3471 4029
A750-04MC250 750-750-750-750+250 750 4 909 80 250 520 65 2724 3048 3517 4088
A750-04MC300 750-750-750-750+300 750 4 909 80 300 571 65 2724 3048 3563 4139
A750-04MC350 750-750-750-750+350 750 4 909 80 350 614 65 2724 3048 3608 4189
A750-04MC400 750-750-750-750+400 750 4 909 80 400 657 65 2780 3103 3666 4251
A750-04MC450 750-750-750-750+450 750 4 909 80 450 701 65 2780 3103 3711 4301
A750-04MC500 750-750-750-750+500 750 4 909 80 500 736 65 2831 3154 3766 4360
A750-04MC600 750-750-750-750+600 750 4 909 80 600 815 80 2886 3209 3869 4493
A750-04MC700 750-750-750-750+700 750 4 909 80 700 878 80 2886 3209 3962 4593
A750-04MC750 750-750-750-750+750 750 4 909 80 750 909 80 2886 3209 4007 4643
A800-04MC1/0 800-800-800-800+1/0 800 4 937 80 1/0 336 55 2654 2977 3552 4111
A800-04MC2/0 800-800-800-800+2/0 800 4 937 80 2/0 376 55 2720 3044 3590 4152
A800-04MC3/0 800-800-800-800+3/0 800 4 937 80 3/0 421 55 2720 3044 3622 4188
A800-04MC4/0 800-800-800-800+4/0 800 4 937 80 4/0 476 55 2744 3068 3666 4238

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
912 Information on this sheet subject to change without notice.
20180201 Copyright © 2018, American Wire Group, Inc.
Type MC Four Conductor w/Ground
Aluminum Armor XHHW-2 600V

Item# Size of Cable Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable
Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight
Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT)
AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor
MCM (mils) AWG/MCM (mils)
A800-04MC250 800-800-800-800+250 800 4 937 80 250 520 65 2744 3068 3703 4287
A800-04MC300 800-800-800-800+300 800 4 937 80 300 571 65 2795 3119 3758 4348
A800-04MC350 800-800-800-800+350 800 4 937 80 350 614 65 2795 3119 3803 4398
A800-04MC400 800-800-800-800+400 800 4 937 80 400 657 65 2850 3174 3861 4460
A800-04MC450 800-800-800-800+450 800 4 937 80 450 701 65 2850 3174 3906 4510
A800-04MC500 800-800-800-800+500 800 4 937 80 500 736 65 2850 3174 3951 4559
A800-04MC600 800-800-800-800+600 800 4 937 80 600 815 80 2906 3229 4054 4692
A800-04MC700 800-800-800-800+700 800 4 937 80 700 878 80 2961 3284 4157 4803
A800-04MC750 800-800-800-800+750 800 4 937 80 750 909 80 2961 3284 4203 4853
A800-04MC800 800-800-800-800+800 800 4 937 80 800 937 80 2961 3284 4248 4901
A900-04MC2/0 900-900-900-900+2/0 900 4 1000 80 2/0 376 55 2807 3131 3977 3977
A900-04MC3/0 900-900-900-900+3/0 900 4 1000 80 3/0 421 55 2878 3202 4022 4022
A900-04MC4/0 900-900-900-900+4/0 900 4 1000 80 4/0 476 55 2902 3225 4066 4066
A900-04MC250 900-900-900-900+250 900 4 1000 80 250 520 65 2902 3225 4103 4103
A900-04MC300 900-900-900-900+300 900 4 1000 80 300 571 65 2957 3280 4158 4158
A900-04MC350 900-900-900-900+350 900 4 1000 80 350 614 65 2957 3280 4204 4204
A900-04MC400 900-900-900-900+400 900 4 1000 80 400 657 65 2957 3280 4251 4251
A900-04MC450 900-900-900-900+450 900 4 1000 80 450 701 65 3016 3339 4307 4307
A900-04MC500 900-900-900-900+500 900 4 1000 80 500 736 65 3016 3339 4353 4353
A900-04MC600 900-900-900-900+600 900 4 1000 80 600 815 80 3075 3398 4456 4456
A900-04MC700 900-900-900-900+700 900 4 1000 80 700 878 80 3075 3398 4549 4549
A900-04MC750 900-900-900-900+750 900 4 1000 80 750 909 80 3130 3454 4605 4605
A900-04MC800 900-900-900-900+800 900 4 1000 80 800 937 80 3130 3454 4650 4650

ARMORED CABLES
A900-04MC900 900-900-900-900+900 900 4 1000 80 900 1000 80 3130 3454 4743 4743
A900-04MC1000 900-900-900-900+1000 900 4 1000 80 1000 1059 80 3130 3454 4835 4835
A1000-04MC2/0 1000-1000-1000-1000+2/0 1000 4 1059 80 2/0 376 55 2949 3272 4374 4374
A1000-04MC3/0 1000-1000-1000-1000+3/0 1000 4 1059 80 3/0 421 55 3024 3347 4420 4420
A1000-04MC4/0 1000-1000-1000-1000+4/0 1000 4 1059 80 4/0 476 55 3024 3347 4459 4459
A1000-04MC250 1000-1000-1000-1000+250 1000 4 1059 80 250 520 65 3047 3371 4500 4500
A1000-04MC300 1000-1000-1000-1000+300 1000 4 1059 80 300 571 65 3047 3371 4546 4546
A1000-04MC350 1000-1000-1000-1000+350 1000 4 1059 80 350 614 65 3106 3430 4602 4602
A1000-04MC400 1000-1000-1000-1000+400 1000 4 1059 80 400 657 65 3106 3430 4649 4649
A1000-04MC450 1000-1000-1000-1000+450 1000 4 1059 80 450 701 65 3106 3430 4695 4695
A1000-04MC500 1000-1000-1000-1000+500 1000 4 1059 80 500 736 65 3169 3493 4752 4752
A1000-04MC600 1000-1000-1000-1000+600 1000 4 1059 80 600 815 80 3228 3552 4856 4856
A1000-04MC650 1000-1000-1000-1000+650 1000 4 1059 80 650 843 80 3228 3552 4901 4901
A1000-04MC700 1000-1000-1000-1000+700 1000 4 1059 80 700 878 80 3228 3552 4948 4948
A1000-04MC750 1000-1000-1000-1000+750 1000 4 1059 80 750 909 80 3228 3552 4994 4994
A1000-04MC800 1000-1000-1000-1000+800 1000 4 1059 80 800 937 80 3228 3552 5039 5039
A1000-04MC900 1000-1000-1000-1000+900 1000 4 1059 80 900 1000 80 3291 3615 5143 5143
A1000-04MC1000 1000-1000-1000-1000+1000 1000 4 1059 80 1000 1059 80 3291 3615 5236 5236

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 912
Copyright © 2018, American Wire Group, Inc. 20180201
NOTES
ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
PowerGuard® Armored 5kV-35kV Copper 3/C with Copper Ground Wire
TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8

Applications
• Armored Medium-Voltage power cables offer an economical, rugged and reliable alternative to
labor-intensive cable in conduit wiring methods
• Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not
more than six feetApart
• Installed in both exposedAnd concealed work, wet or dry locations, directly buried or embedded
in concrete
Construction
Conductor: Class A or B Compressed concentric stranded copper conductor. Optional water-block-
ing.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation
Insulation: Extruded, unfilled Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in
aNSI/ICEA S-94-649
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the in-
sulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield:The metallic shield is flat uncoated 5-mil thick copper tape helically applied with
minimum 20% overlap
Ground Wire: Three bare copper ground wires placed at the interstice of the conductor.
Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core.
Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability.
Armor: Aluminum Interlocked armor applied over the binder tape of the cable core
Jacket: Black, sunlight resistant, flame retardant PVC jacket

Specifications
• AEIC CS8, Specifications for Shielded Power Cable, 5-46kV
• ICEA S-93-639, 5-46 kV Shielded Power Cable
• ICEA S-97-682, Utility Shielded Power Cable Rated 5-46kV
• UL-1072 MV-105
• UL-1569, Metal Clad Cables
• IEEE 383 Flame Test
• For 105°C continuous, 140°C emergency, 250°C short-circuit operation.

ARMORED CABLES
• UL MC-HLAvailable upon request
NOTES:
• The above dimensions are approximate and subject to normal manufacturing tolerances.
• Ampacities are based on the following: Three Phase Operation In Duct (2011 NEC Table
310.60(C)(80): Three-conductor cable in plastic duct, direct-buried, 105°C conductor temperature,
20°C ambient temperature, earth RHO of 90°C-cm/Watt, and 100% load factor, and shields short-
circuited. Isolated in air (2011 NEC Table 310.60(C)(72)): Three-conductor cable, 105°C conductor
temperature, and 40°C ambient temperature, and shields grounded at one point only. In Cable
Tray: per 2011 NEC 392.80(B)(1)(b)3, for single conductor cables, sizes 1/0 AWG and larger, in-
stalled in a single layer in an uncovered table tray, with a maintained space of not less than one
cable diameter between individual conductors, the ampacities shall not exceed the allowable am-
pacities stated in 2011 NEC Table 310.60(C)(72) (Aluminum), “Isolated in air” values noted above.
• Insulated cables are capable of operating at 105°C. However, the maximum operating tempera-
ture of the cable should be based on the maximum operating temperature of the cable acces-
sories to be used.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 903
Copyright © 2018, American Wire Group, Inc. 20140921
PowerGuard® Armored 5kV-35kV Copper 3/C with Copper Ground Wire
TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8

Item # Size Insulation No. of Size of Conductor Insulation Insulation Overall Approx. Minimum Ampacity Ampacity
AWG Thickness Ground Ground Diameter Diameter Shield Jacket Weight Bending 90°C 90°C
or (mil) Wires Wires (in) (in) (in) (in) (lb/MFT) Radius in Duct inAir
KCMIL (in)
5kV Copper 100%
2-03AIAPC5GT105 2 90 3 10 0.266 0.5 0.56 1.58 1585 12 145 154
1-03AIAPC5GT105 1 90 3 8 0.299 0.53 0.59 1.68 1829 12 165 180
1/0-03AIAPC5GT105 1/0 90 3 8 0.341 0.57 0.63 1.77 2111 13 190 205
2/0-03AIAPC5GT105 2/0 90 3 8 0.376 0.61 0.67 1.86 2540 14 220 240
3/0-03AIAPC5GT105 3/0 90 3 7 0.423 0.66 0.71 1.96 2951 14 250 280
4/0-03AIAPC5GT105 4/0 90 3 7 0.479 0.71 0.77 2.08 3458 15 285 320
250-03AIAPC5GT105 250 90 3 7 0.522 0.76 0.82 2.19 3914 16 315 355
350-03AIAPC5GT105 350 90 3 6 0.622 0.86 0.92 2.44 5146 18 380 440
500-03AIAPC5GT105 500 90 3 5 0.742 0.98 1.05 2.73 6898 20 460 545
750-03AIAPC5GT105 750 90 3 4 0.917 1.16 1.24 3.14 9832 23 570 685
1000-03AIAPC5GT105 1000 90 3 4 1.071 1.32 1.39 3.48 12524 25 645 790
5kV Copper 133%
4-03AIAPC5UT105 4 115 3 10 0.215 0.5 0.56 1.58 1381 12 110 115
2-03AIAPC5UT105 2 115 3 10 0.266 0.55 0.61 1.71 1740 12 145 154
1-03AIAPC5UT105 1 115 3 8 0.299 0.58 0.64 1.78 1959 13 165 180
1/0-03AIAPC5UT105 1/0 115 3 8 0.341 0.62 0.68 1.89 2299 14 190 205
2/0-03AIAPC5UT105 2/0 115 3 8 0.376 0.66 0.72 1.97 2684 14 220 240
3/0-03AIAPC5UT105 3/0 115 3 7 0.423 0.71 0.76 2.07 3102 15 250 280
4/0-03AIAPC5UT105 4/0 115 3 7 0.479 0.76 0.82 2.19 3617 16 285 320
250-03AIAPC5UT105 250 115 3 7 0.522 0.81 0.87 2.3 4080 17 315 355
350-03AIAPC5UT105 350 115 3 6 0.622 0.91 0.97 2.54 5329 18 380 440
500-03AIAPC5UT105 500 115 3 5 0.742 1.03 1.1 2.84 7101 20 460 545
750-03AIAPC5UT105 750 115 3 4 0.917 1.21 1.29 3.25 10062 23 570 685
ARMORED CABLES

1000-03AIAPC5UT105 1000 115 3 4 1.071 1.37 1.44 3.59 12776 26 645 790

8kV Copper 100%


4-03AIAPC8GT105 4 115 3 10 0.215 0.5 0.56 1.58 1381 12 125 135
2-03AIAPC8GT105 2 115 3 10 0.266 0.55 0.61 1.71 1740 12 160 185
1-03AIAPC8GT105 1 115 3 8 0.299 0.58 0.64 1.78 1959 13 185 210
1/0-03AIAPC8GT105 1/0 115 3 8 0.341 0.62 0.68 1.89 2299 14 210 240
2/0-03AIAPC8GT105 2/0 115 3 8 0.376 0.66 0.72 1.97 2684 14 235 275
3/0-03AIAPC8GT105 3/0 115 3 7 0.423 0.71 0.76 2.07 3102 15 270 315
4/0-03AIAPC8GT105 4/0 115 3 7 0.479 0.76 0.82 2.19 3617 16 305 360
250-03AIAPC8GT105 250 115 3 7 0.522 0.81 0.87 2.3 4080 17 335 400
350-03AIAPC8GT105 350 115 3 6 0.622 0.91 0.97 2.54 5329 18 400 490
500-03AIAPC8GT105 500 115 3 5 0.742 1.03 1.1 2.84 7101 20 485 600
750-03AIAPC8GT105 750 115 3 4 0.917 1.21 1.29 3.25 10062 23 585 745
1000-03AIAPC8GT105 1000 115 3 4 1.071 1.37 1.44 3.59 12776 26 660 860

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
903 Information on this sheet subject to change without notice.
20140921 Copyright © 2018, American Wire Group, Inc.
PowerGuard® Armored 5kV-35kV Copper 3/C with Copper Ground Wire
TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8

Item # Size Insulation No. of Size of Conductor Insulation Insulation Overall Approx. Minimum Ampacity Ampacity
AWG Thickness Ground Ground Diameter Diameter Shield Jacket Weight Bending 90°C 90°C
or (mil) Wires Wires (in) (in) (in) (in) (lb/MFT) Radius in Duct inAir
KCMIL (in)
8kV Copper 133%
2-03AIAPC8UT105 2 140 3 10 0.266 0.6 0.66 1.82 1873 13 160 185
1-03AIAPC8UT105 1 140 3 8 0.299 0.63 0.69 1.91 2149 14 185 210
1/0-03AIAPC8UT105 1/0 140 3 8 0.341 0.67 0.73 2 2446 15 210 240
2/0-03AIAPC8UT105 2/0 140 3 8 0.376 0.71 0.77 2.08 2836 15 235 275
3/0-03AIAPC8UT105 3/0 140 3 7 0.423 0.76 0.81 2.18 3260 16 270 315
4/0-03AIAPC8UT105 4/0 140 3 7 0.479 0.81 0.87 2.3 3783 17 305 360
250-03AIAPC8UT105 250 140 3 7 0.522 0.86 0.92 2.44 4321 18 335 400
350-03AIAPC8UT105 350 140 3 6 0.622 0.96 1.02 2.65 5519 19 400 490
500-03AIAPC8UT105 500 140 3 5 0.742 1.08 1.15 2.95 7310 21 485 600
750-03AIAPC8UT105 750 140 3 4 0.917 1.26 1.34 3.36 10299 24 585 745
1000-03AIAPC8UT105 1000 140 3 4 1.071 1.42 1.49 3.69 13035 26 660 860

15kV Copper 100%


2-03AIAPC15GT105 2 175 3 10 0.266 0.67 0.73 1.99 2126 14 160 185
1-03AIAPC15GT105 1 175 3 8 0.299 0.7 0.76 2.06 2358 15 185 210
1/0-03AIAPC15GT105 1/0 175 3 8 0.341 0.74 0.8 2.15 2663 16 210 240
2/0-03AIAPC15GT105 2/0 175 3 8 0.376 0.78 0.84 2.23 3060 16 235 275
3/0-03AIAPC15GT105 3/0 175 3 7 0.423 0.83 0.88 2.33 3494 17 270 315
4/0-03AIAPC15GT105 4/0 175 3 7 0.479 0.88 0.94 2.48 4097 18 305 360
250-03AIAPC15GT105 250 175 3 7 0.522 0.93 0.99 2.59 4579 19 335 400
350-03AIAPC15GT105 350 175 3 6 0.622 1.03 1.1 2.84 5864 20 400 490
500-03AIAPC15GT105 500 175 3 5 0.742 1.15 1.22 3.1 7615 22 485 600
750-03AIAPC15GT105 750 175 3 4 0.917 1.33 1.41 3.51 10644 25 585 745

ARMORED CABLES
1000-03AIAPC15GT105 1000 175 3 4 1.071 1.49 1.58 3.88 13500 28 660 860
15kV Copper 133%
2-03AIAPC15UT105 2 220 3 10 0.266 0.76 0.82 2.19 2406 16 160 185
1-03AIAPC15UT105 1 220 3 8 0.299 0.79 0.85 2.26 2647 16 185 210
1/0-03AIAPC15UT105 1/0 220 3 8 0.341 0.83 0.89 2.35 2962 17 210 240
2/0-03AIAPC15UT105 2/0 220 3 8 0.376 0.87 0.93 2.45 3437 18 235 275
3/0-03AIAPC15UT105 3/0 220 3 7 0.423 0.92 0.97 2.55 3886 18 270 315
4/0-03AIAPC15UT105 4/0 220 3 7 0.479 0.97 1.03 2.68 4437 19 305 360
250-03AIAPC15UT105 250 220 3 7 0.522 1.02 1.09 2.82 4998 20 335 400
350-03AIAPC15UT105 350 220 3 6 0.622 1.12 1.19 3.03 6247 22 400 490
500-03AIAPC15UT105 500 220 3 5 0.742 1.24 1.31 3.31 8090 24 485 600
750-03AIAPC15UT105 750 220 3 4 0.917 1.42 1.5 3.71 11107 26 585 745
1000-03AIAPC15UT105 1000 220 3 4 1.071 1.58 1.67 4.07 14006 29 660 860

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 903
Copyright © 2018, American Wire Group, Inc. 20140921
PowerGuard® Armored 5kV-35kV Copper 3/C with Copper Ground Wire
TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8

Item # Size Insulation No. of Size of Conductor Insulation Insulation Overall Approx. Minimum Ampacity Ampacity
AWG Thickness Ground Ground Diameter Diameter Shield Jacket Weight Bending 90°C 90°C
or (mil) Wires Wires (in) (in) (in) (in) (lb/MFT) Radius in Duct in Air
KCMIL (in)
25kV Copper 100%
1-03AIAPC25GT105 1 260 3 8 0.299 0.87 0.93 2.46 2991 18 185 210
1/0-03AIAPC25GT105 1/0 260 3 8 0.341 0.91 0.97 2.55 3319 18 210 240
2/0-03AIAPC25GT105 2/0 260 3 8 0.376 0.95 1.01 2.63 3735 19 235 275
3/0-03AIAPC25GT105 3/0 260 3 7 0.423 1 1.07 2.76 4260 20 270 315
4/0-03AIAPC25GT105 4/0 260 3 7 0.479 1.05 1.13 2.88 4827 21 305 360
250-03AIAPC25GT105 250 260 3 7 0.522 1.1 1.17 2.99 5334 21 335 400
350-03AIAPC25GT105 350 260 3 6 0.622 1.2 1.27 3.22 6666 23 400 490
500-03AIAPC25GT105 500 260 3 5 0.742 1.32 1.39 3.48 8480 25 485 600
750-03AIAPC25GT105 750 260 3 4 0.917 1.5 1.59 3.91 11628 28 585 745
25kV Copper 133%
1-03AIAPC25UT105 1 345 3 8 0.299 0.98 1.04 2.68 3326 19 185 210
1/0-03AIAPC25UT105 1/0 345 3 8 0.341 1.09 1.16 2.96 4082 21 210 240
2/0-03AIAPC25UT105 2/0 345 3 8 0.376 1.12 1.2 3.04 4517 22 235 275
3/0-03AIAPC25UT105 3/0 345 3 7 0.423 1.17 1.24 3.14 5002 22 270 315
4/0-03AIAPC25UT105 4/0 345 3 7 0.479 1.23 1.3 3.28 5658 23 305 360
250-03AIAPC25UT105 250 345 3 7 0.522 1.27 1.35 3.38 6192 24 335 400
350-03AIAPC25UT105 350 345 3 6 0.622 1.37 1.45 3.6 7516 26 400 490
500-03AIAPC25UT105 500 345 3 5 0.742 1.49 1.58 3.89 9479 28 485 600

35kV Copper 100%


1/0-03AIAPC35GT105 1/0 345 3 8 0.341 1.09 1.16 2.96 4082 21 210 240
2/0-03AIAPC35GT105 2/0 345 3 8 0.376 1.12 1.2 3.04 4517 22 235 275
3/0-03AIAPC35GT105 3/0 345 3 7 0.423 1.17 1.24 3.14 5002 22 270 315
ARMORED CABLES

4/0-03AIAPC35GT105 4/0 345 3 7 0.479 1.23 1.3 3.28 5658 23 305 360
250-03AIAPC35GT105 250 345 3 7 0.522 1.27 1.35 3.38 6192 24 335 400
350-03AIAPC35GT105 350 345 3 6 0.622 1.37 1.45 3.6 7516 26 400 490
500-03AIAPC35GT105 500 345 3 5 0.742 1.49 1.58 3.89 9479 28 485 600
35kV Copper 133%
1/0-03AIAPC35UT105 1/0 420 3 8 0.341 1.24 1.31 3.3 4818 24 210 240
2/0-03AIAPC35UT105 2/0 420 3 8 0.376 1.27 1.35 3.38 5269 24 235 275
3/0-03AIAPC35UT105 3/0 420 3 7 0.423 1.32 1.39 3.48 5776 25 270 315
4/0-03AIAPC35UT105 4/0 420 3 7 0.479 1.38 1.45 3.6 6397 26 305 360
250-03AIAPC35UT105 250 420 3 7 0.522 1.42 1.5 3.71 6951 26 335 400
350-03AIAPC35UT105 350 420 3 6 0.622 1.52 1.61 3.96 8409 28 400 490

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
903 Information on this sheet subject to change without notice.
201401916 Copyright © 2018, American Wire Group, Inc.
PowerGuard® Armored 5kV-35kV Aluminum 3/C with Copper Ground Wire
TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC,AEIC CS8

Applications
• Armored Medium-Voltage power cables offer an economical, rugged and reliable alternative to
labor-intensive cable in conduit wiring methods
• Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not
more than six feet apart
• Installed in both exposed and concealed work, wet or dry locations, directly buried or embedded
in concrete
Construction
Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231.
Stranded conductors are water-blocked with conductor filling compound.
Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the
conductor and bonded to the insulation
Insulation: Extruded, unfilled Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in
ANSI/ICEA S-94-649
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the in-
sulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield:The metallic shield is flat uncoated 5-mil thick copper tape helically applied with
minimum 20% overlap
Ground Wire: Three bare copper ground wires placed at the interstice of the conductor.
Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core.
Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability.
Armor: Aluminum Interlocked armor applied over the binder tape of the cable core
Jacket: Black, sunlight resistant, flame retardant PVC jacket

Specifications
• AEIC CS8, Specifications for Shielded Power Cable, 5-46kV
• ICEA S-93-639, 5-46 kV Shielded Power Cable
• ICEA S-97-682, Utility Shielded Power Cable Rated 5-46 kV
• UL-1072 MV-105
• UL-1569, Metal Clad Cables
• IEEE 383 Flame Test
• For 105°C continuous, 140°C emergency, 250°C short-circuit operation.

ARMORED CABLES
• UL MC-HL available upon request
NOTES:
• The above dimensions are approximate and subject to normal manufacturing tolerances.
• Ampacities are based on the following: Three Phase Operation In Duct (2011 NEC Table
310.60(C)(80): Three-conductor cable in plastic duct, direct-buried, 105°C conductor temperature,
20°C ambient temperature, earth RHO of 90°C-cm/Watt, and 100% load factor, and shields short-
circuited. Isolated in air (2011 NEC Table 310.60(C)(72)): Three-conductor cable, 105°C conductor
temperature, and 40°C ambient temperature, and shields grounded at one point only. In Cable
Tray: per 2011 NEC 392.80(B)(1)(b)3, for single conductor cables, sizes 1/0AWG and larger, in-
stalled in a single layer in an uncovered table tray, with a maintained space of not less than one
cable diameter between individual conductors, the ampacities shall not exceed the allowable am-
pacities stated in 2011 NEC Table 310.60(C)(72) (Aluminum), “Isolated in air” values noted above.
• Insulated cables are capable of operating at 105°C. However, the maximum operating tempera-
ture of the cable should be based on the maximum operating temperature of the cable acces-
sories to be used.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 904
Copyright © 2018, American Wire Group, Inc. 20140921
PowerGuard® Armored 5kV-35kVAluminum 3/C with Copper Ground Wire
TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8

Item # Size Insulation No. of Size of Conductor Insulation Insulation Overall Approx. Minimum Ampacity Ampacity
AWG Thickness Ground Ground Diameter Diameter Shield Jacket Weight Bending 90°C 90°C
or (mil) Wires Wires (in) (in) (in) (in) (lb/MFT) Radius in Duct in Air
KCMIL (in)
5kVAluminum 100%
A4-03AIAPC5GT105 4 90 3 10 0.215 0.45 0.51 1.47 1001 11 86 90
A2-03AIAPC5GT105 2 90 3 10 0.266 0.5 0.56 1.58 1165 12 110 120
A1-03AIAPC5GT105 1 90 3 10 0.299 0.53 0.59 1.68 1298 12 130 140
A1/0-03AIAPC5GT105 1/0 90 3 10 0.336 0.57 0.63 1.75 1431 13 150 160
A2/0-03AIAPC5GT105 2/0 90 3 8 0.379 0.61 0.67 1.87 1698 14 170 185
A3/0-03AIAPC5GT105 3/0 90 3 8 0.423 0.66 0.71 1.96 1887 14 195 215
A4/0-03AIAPC5GT105 4/0 90 3 8 0.479 0.71 0.77 2.08 2121 15 220 250
A250-03AIAPC5GT105 250 90 3 8 0.522 0.76 0.82 2.19 2338 16 245 280
A350-03AIAPC5GT105 350 90 3 7 0.622 0.86 0.92 2.44 2927 18 310 345
A500-03AIAPC5GT105 500 90 3 6 0.742 0.98 1.05 2.73 3734 20 365 430
A750-03AIAPC5GT105 750 90 3 5 0.917 1.16 1.24 3.14 4987 23 460 550
A1000-03AIAPC5GT105 1000 90 3 4 1.071 1.32 1.39 3.48 6177 25 535 650
5kVAluminum 133%
A4-03AIAPC5UT105 4 115 3 10 0.215 0.5 0.56 1.58 1117 12 86 90
A2-03AIAPC5UT105 2 115 3 10 0.266 0.55 0.61 1.71 1321 12 110 120
A1-03AIAPC5UT105 1 115 3 10 0.299 0.58 0.64 1.78 1429 13 130 140
A1/0-03AIAPC5UT105 1/0 115 3 10 0.336 0.62 0.68 1.88 1619 14 150 160
A2/0-03AIAPC5UT105 2/0 115 3 8 0.379 0.66 0.72 1.98 1843 14 170 185
A3/0-03AIAPC5UT105 3/0 115 3 8 0.423 0.71 0.76 2.07 2038 15 195 215
A4/0-03AIAPC5UT105 4/0 115 3 8 0.479 0.76 0.82 2.19 2280 16 220 250
A250-03AIAPC5UT105 250 115 3 8 0.522 0.81 0.87 2.3 2504 17 245 280
A350-03AIAPC5UT105 350 115 3 7 0.622 0.91 0.97 2.54 3110 18 310 345
A500-03AIAPC5UT105 500 115 3 6 0.742 1.03 1.1 2.84 3937 20 365 430
ARMORED CABLES

A750-03AIAPC5UT105 750 115 3 5 0.917 1.21 1.29 3.25 5218 23 460 550
A1000-03AIAPC5UT105 1000 115 3 4 1.071 1.37 1.44 3.59 6429 26 535 650

8kVAluminum 100%
A4-03AIAPC8GT105 4 115 3 10 0.215 0.5 0.56 1.58 1117 12 96 105
A2-03AIAPC8GT105 2 115 3 10 0.266 0.55 0.61 1.71 1321 12 125 145
A1-03AIAPC8GT105 1 115 3 10 0.299 0.58 0.64 1.78 1429 13 145 165
A1/0-03AIAPC8GT105 1/0 115 3 10 0.336 0.62 0.68 1.88 1619 14 165 185
A2/0-03AIAPC8GT105 2/0 115 3 8 0.379 0.66 0.72 1.98 1843 14 185 215
A3/0-03AIAPC8GT105 3/0 115 3 8 0.423 0.71 0.76 2.07 2038 15 210 245
A4/0-03AIAPC8GT105 4/0 115 3 8 0.479 0.76 0.82 2.19 2280 16 240 285
A250-03AIAPC8GT105 250 115 3 8 0.522 0.81 0.87 2.3 2504 17 265 315
A350-03AIAPC8GT105 350 115 3 7 0.622 0.91 0.97 2.54 3110 18 315 385
A500-03AIAPC8GT105 500 115 3 6 0.742 1.03 1.1 2.84 3937 20 385 475
A750-03AIAPC8GT105 750 115 3 5 0.917 1.21 1.29 3.25 5218 23 475 600
A1000-03AIAPC8GT105 1000 115 3 4 1.071 1.37 1.44 3.59 6429 26 545 705

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
904 Information on this sheet subject to change without notice.
20140921 Copyright © 2018, American Wire Group, Inc.
PowerGuard® Armored 5kV-35kV Aluminum 3/C with Copper Ground Wire
TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8

Item # Size Insulation No. of Size of Conductor Insulation Insulation Overall Approx. Minimum Ampacity Ampacity
AWG Thickness Ground Ground Diameter Diameter Shield Jacket Weight Bending 90°C 90°C
or (mil) Wires Wires (in) (in) (in) (in) (lb/MFT) Radius in Duct in Air
KCMIL (in)
8kVAluminum 133%
A2-03AIAPC8UT105 2 140 3 10 0.266 0.6 0.66 1.82 1454 13 125 145
A1-03AIAPC8UT105 1 140 3 10 0.299 0.63 0.69 1.91 1619 14 145 165
A1/0-03AIAPC8UT105 1/0 140 3 10 0.336 0.67 0.73 1.99 1764 14 165 185
A2/0-03AIAPC8UT105 2/0 140 3 8 0.379 0.71 0.77 2.08 1995 15 185 215
A3/0-03AIAPC8UT105 3/0 140 3 8 0.423 0.76 0.81 2.18 2196 16 210 245
A4/0-03AIAPC8UT105 4/0 140 3 8 0.479 0.81 0.87 2.3 2446 17 240 285
A250-03AIAPC8UT105 250 140 3 8 0.522 0.86 0.92 2.44 2745 18 265 315
A350-03AIAPC8UT105 350 140 3 7 0.622 0.96 1.02 2.65 3300 19 315 385
A500-03AIAPC8UT105 500 140 3 6 0.742 1.08 1.15 2.95 4146 21 385 475
A750-03AIAPC8UT105 750 140 3 5 0.917 1.26 1.34 3.36 5455 24 475 600
A1000-03AIAPC8UT105 1000 140 3 4 1.071 1.42 1.49 3.69 6689 26 545 705

15kVAluminum 100%
A2-03AIAPC15GT105 2 175 3 10 0.266 0.67 0.73 1.99 1706 14 125 145
A1-03AIAPC15GT105 1 175 3 10 0.299 0.7 0.76 2.06 1828 15 145 165
A1/0-03AIAPC15GT105 1/0 175 3 10 0.336 0.74 0.8 2.14 1980 15 165 185
A2/0-03AIAPC15GT105 2/0 175 3 8 0.379 0.78 0.84 2.24 2219 16 185 215
A3/0-03AIAPC15GT105 3/0 175 3 8 0.423 0.83 0.88 2.33 2430 17 210 245
A4/0-03AIAPC15GT105 4/0 175 3 8 0.479 0.88 0.94 2.48 2760 18 240 285
A250-03AIAPC15GT105 250 175 3 8 0.522 0.93 0.99 2.59 3003 19 265 315
A350-03AIAPC15GT105 350 175 3 7 0.622 1.03 1.1 2.84 3645 20 315 385
A500-03AIAPC15GT105 500 175 3 6 0.742 1.15 1.22 3.1 4451 22 385 475
A750-03AIAPC15GT105 750 175 3 5 0.917 1.33 1.41 3.51 5799 25 475 600

ARMORED CABLES
A1000-03AIAPC15GT1051000 175 3 4 1.071 1.49 1.58 3.88 7153 28 545 705
15kVAluminum 133%
A2-03AIAPC15UT105 2 220 3 10 0.266 0.76 0.82 2.19 1987 16 125 145
A1-03AIAPC15UT105 1 220 3 10 0.299 0.79 0.85 2.26 2116 16 145 165
A1/0-03AIAPC15UT105 1/0 220 3 10 0.336 0.83 0.89 2.34 2279 17 165 185
A2/0-03AIAPC15UT105 2/0 220 3 8 0.379 0.87 0.93 2.46 2597 18 185 215
A3/0-03AIAPC15UT105 3/0 220 3 8 0.423 0.92 0.97 2.55 2821 18 210 245
A4/0-03AIAPC15UT105 4/0 220 3 8 0.479 0.97 1.03 2.68 3100 19 240 285
A250-03AIAPC15UT105 250 220 3 8 0.522 1.02 1.09 2.82 3422 20 265 315
A350-03AIAPC15UT105 350 220 3 7 0.622 1.12 1.19 3.03 4027 22 315 385
A500-03AIAPC15UT105 500 220 3 6 0.742 1.24 1.31 3.31 4926 24 385 475
A750-03AIAPC15UT105 750 220 3 5 0.917 1.42 1.5 3.71 6262 26 475 600
A1000-03AIAPC15UT1051000 220 3 4 1.071 1.58 1.67 4.07 7659 29 545 705

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 904
Copyright © 2018, American Wire Group, Inc. 20140921
PowerGuard® Armored 5kV-35kV Aluminum 3/C with Copper Ground Wire
TR-XLPE Insulation Copper Tape Shield AIA
PVC Jacket UL Type MV-105 or MC, AEIC CS8

Item # Size Insulation No. of Size of Conductor Insulation Insulation Overall Approx. Minimum Ampacity Ampacity
AWG Thickness Ground Ground Diameter Diameter Shield Jacket Weight Bending 90°C 90°C
or (mil) Wires Wires (in) (in) (in) (in) (lb/MFT) Radius in Duct inAir
KCMIL (in)
25kVAluminum 100%
A1-03AIAPC25GT105 1 260 3 10 0.299 0.87 0.93 2.46 2461 18 145 165
A1/0-03AIAPC25GT105 1/0 260 3 10 0.336 0.91 0.97 2.54 2634 18 165 185
A2/0-03AIAPC25GT105 2/0 260 3 8 0.379 0.95 1.01 2.63 2896 19 185 215
A3/0-03AIAPC25GT105 3/0 260 3 8 0.423 1 1.07 2.76 3196 20 210 245
A4/0-03AIAPC25GT105 4/0 260 3 8 0.479 1.05 1.13 2.88 3489 21 240 285
A250-03AIAPC25GT105 250 260 3 8 0.522 1.1 1.17 2.99 3759 21 265 315
A350-03AIAPC25GT105 350 260 3 7 0.622 1.2 1.27 3.22 4447 23 315 385
A500-03AIAPC25GT105 500 260 3 6 0.742 1.32 1.39 3.48 5316 25 385 475
A750-03AIAPC25GT105 750 260 3 5 0.917 1.5 1.59 3.91 6783 28 475 600
25kVAluminum 133%
A1/0-03AIAPC25UT105 1/0 345 3 10 0.336 1.08 1.16 2.95 3395 21 165 185
A2/0-03AIAPC25UT105 2/0 345 3 8 0.379 1.13 1.2 3.04 3680 22 185 215
A3/0-03AIAPC25UT105 3/0 345 3 8 0.423 1.17 1.24 3.14 3938 22 210 245
A4/0-03AIAPC25UT105 4/0 345 3 8 0.479 1.23 1.3 3.28 4321 23 240 285
A250-03AIAPC25UT105 250 345 3 8 0.522 1.27 1.35 3.38 4616 24 265 315
A350-03AIAPC25UT105 350 345 3 7 0.622 1.37 1.45 3.6 5297 26 315 385
A500-03AIAPC25UT105 500 345 3 6 0.742 1.49 1.58 3.89 6315 28 385 475

35kVAluminum 100%
A1/0-03AIAPC35GT105 1/0 345 3 10 0.336 1.08 1.16 2.95 3395 21 165 185
A2/0-03AIAPC35GT105 2/0 345 3 8 0.379 1.13 1.2 3.04 3680 22 185 215
A3/0-03AIAPC35GT105 3/0 345 3 8 0.423 1.17 1.24 3.14 3938 22 210 245
A4/0-03AIAPC35GT105 4/0 345 3 8 0.479 1.23 1.3 3.28 4321 23 240 285
ARMORED CABLES

A250-03AIAPC35GT105 250 345 3 8 0.522 1.27 1.35 3.38 4616 24 265 315
A350-03AIAPC35GT105 350 345 3 7 0.622 1.37 1.45 3.6 5297 26 315 385
A500-03AIAPC35GT105 500 345 3 6 0.742 1.49 1.58 3.89 6315 28 385 475
35kVAluminum 133%
A1/0-03AIAPC35UT105 1/0 420 3 10 0.336 1.23 1.31 3.29 4128 24 165 185
A2/0-03AIAPC35UT105 2/0 420 3 8 0.379 1.28 1.35 3.39 4433 24 185 215
A3/0-03AIAPC35UT105 3/0 420 3 8 0.423 1.32 1.39 3.48 4712 25 210 245
A4/0-03AIAPC35UT105 4/0 420 3 8 0.479 1.38 1.45 3.6 5059 26 240 285
A250-03AIAPC35UT105 250 420 3 8 0.522 1.42 1.5 3.71 5375 26 265 315
A350-03AIAPC35UT105 350 420 3 7 0.622 1.52 1.61 3.96 6190 28 315 385

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
904 Information on this sheet subject to change without notice.
20140921 Copyright © 2018, American Wire Group, Inc.
Continuously Corrugated Welded Armored Power Cable
FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 1/C

Application
All cables produced to this specification are recognized by the NECAs 600 Volt Type MC-HL and are
suitable for use as described in the code. The conductor temperatures are rated for continuous oper-
ation of 90°C, for emergency overload of 130°C and for short circuit of 250°C. The cables meet the
requirements for application in NEC Class I , Class II and Class III, Div. 1 and 2, Hazardous Locations
covered under NEC articles 501, 502 and 503. The cables are intended for use in industrial applica-
tions where aluminum armor protection is necessary. The continuously welded sheath serves to
provide a completely moisture impervious barrier for the core as well as providing superior electro
static shielding characteristics. The cables may be used in wet or dry applications, installed in racks,
trays or aerially.
These cables have an overall jacket and can be direct buried in earth and buried in concrete.
Three conductor cables are manufactured in accordance with industry accepted practice of using
three symmetrically placed grounds making them advantageous for use in pulse-width modulated
cables and variable frequency drive applications.

Construction
This specification covers single and multi-conductor power cables insulated with flame retardant
crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and
the assembly are encased in a moisture impervious continuously welded corrugated aluminum
armor, and covered with a protective jacket overall. Three conductor type cables are constructed for
VFD applications.
Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements
ofASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM
B496.
Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concen-
trically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant govern-
ing specification.
Conductor Coding - Phase identification is provided by number code on each insulated conductor.
Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3
conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied con-
centric wires for single conductor cables. The total ground wire cross section in all cases meets the
minimum UL requirements for ground size.
Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers

ARMORED CABLES
make the cable round. a binder tape is applied.
Armor - Over the taped assembly there is continuously welded corrugated aluminum armor.
Jacket -A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin
jacket is extruded for a tight fit over the interlocked armor.

Specifications
• National Fire ProtectionAssociation (NFPA 70) National Electric Code (NEC)
• UL 1569 Metal Clad Cables
• UL 44 Thermoset-Insulated WiresAnd Cables
• ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables
• IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies
(70,000 BTU)
• ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU)
• Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables.
• Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables.
• Listed by ULAs Type MC-HL per Standard UL 1569 Metal-Clad Cables.
• Listed by ULAs Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202.
Options
• Custom ground sizes
• CPE jacket.
Notes
**Based on single cable in uncovered cable tray at 30°C ambient temperature per NEC. For other in-
stallations refer to the NEC.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 905
Copyright © 2018, AAmerican Wire Group, Inc. 20160220
Continuously Corrugated Welded Armored Power Cable
FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 1/C

Item # Conductor Conductor Conductor Insulation Jacket No. xAWG Approximate Ampacity** Approximate
Size No. of Nominal (mil) (mil) Copper O.D. 90°C Net
(AWG/kcmil) Strands O.D. Ground (in) Weight
(in) Wires (lb/MFT)
CWCAPC-1-1/0 1/0 19 0.34 55 50 10 x 14 1.19 170 800
CWCAPC-1-2/0 2/0 19 0.38 55 50 10 x 14 1.23 195 900
CWCAPC-1-3/0 3/0 19 0.42 55 50 13 x 14 1.28 225 1065
CWCAPC-1-4/0 4/0 19 0.48 55 50 16 x 14 1.33 260 1255
CWCAPC-1-250 250 37 0.52 65 50 10 x 12 1.44 295 1440
CWCAPC-1-300 300 37 0.57 65 50 13 x 12 1.44 325 1660
CWCAPC-1-350 350 37 0.62 65 50 13 x 12 1.44 370 1820
CWCAPC-1-400 400 37 0.66 65 50 16 x 12 1.44 400 2040
CWCAPC-1-500 500 37 0.74 65 50 16 x 12 1.44 455 2360
CWCAPC-1-600 600 61 0.81 80 60 16 x 12 1.57 585 2735
CWCAPC-1-750 750 61 0.91 80 60 13 x 10 1.77 660 3375
CWCAPC-1-1000* 1000 61 1.12 80 60 16 x 10 1.87 790 4305
ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
905 Information on this sheet subject to change without notice.
20160220 Copyright © 2018, American Wire Group, Inc.
Continuously Corrugated Welded Armored Power Cable
FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 2/C

Application
All cables produced to this specification are recognized by the NECAs 600 Volt Type MC-HL and are
suitable for use as described in the code. The conductor temperatures are rated for continuous oper-
ation of 90°C, for emergency overload of 130°C and for short circuit of 250°C. The cables meet the
requirements for application in NEC Class I, Class II and Class III, Div. 1 and 2, Hazardous Locations
covered under NEC articles 501, 502 and 503. The cables are intended for use in industrial applica-
tions where aluminum armor protection is necessary. The continuously welded sheath serves to
provide a completely moisture impervious barrier for the core as well as providing superior electro
static shielding characteristics. The cables may be used in wet or dry applications, installed in racks,
trays or aerially.
These cables have an overall jacket and can be direct buried in earth and buried in concrete.
Three conductor cables are manufactured in accordance with industry accepted practice of using
three symmetrically placed grounds making them advantageous for use in pulse-width modulated
cables and variable frequency drive applications.

Construction
This specification covers single and multi-conductor power cables insulated with flame retardant
crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and
the assembly are encased in a moisture impervious continuously welded corrugated aluminum
armor, and covered with a protective jacket overall. Three conductor type cables are constructed for
VFD applications.
Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements
ofASTM B3. Unless otherwise specified the conductors are supplied as compact round perASTM
B496.
Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concen-
trically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant govern-
ing specification.
Conductor Coding - Phase identification is provided by number code on each insulated conductor.
Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3
Copper Conductor conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied con-
XLP Insulation centric wires for single conductor cables. The total ground wire cross section in all cases meets the
Filters
minimum UL requirements for ground size.
Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers

ARMORED CABLES
Copper Ground Wire
Binder Tape make the cable round. A binder tape is applied.
CorrugatedArmor Armor - Over the taped assembly there is continuously welded corrugated aluminum armor.
PVC Jacket Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin
jacket is extruded for a tight fit over the interlocked armor.

Specifications
• National Fire Protection Association (NFPA 70) National Electric Code (NEC)
• UL 1569 Metal Clad Cables
• UL 44 Thermoset-Insulated Wires and Cables
• ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables
• IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies
(70,000 BTU)
• ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU)
• Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables.
• Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables.
• Listed by ULAs Type MC-HL per Standard UL 1569 Metal-Clad Cables.
• Listed by ULAs Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202.
Options
• Custom ground sizes
• CPE jacket.
Notes
**Based on single cable in uncovered cable tray at 30°C ambient temperature per NEC. For other in-
stallations refer to the NEC.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 906
Copyright © 2018, AAmerican Wire Group, Inc. 20160220
Continuously Corrugated Welded Armored Power Cable
FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 2/C

Item # Conductor Conductor Conductor Insulation Jacket No. xAWG Approximate Ampacity** Approximate
Size No. of Nominal (mil) (mil) Copper O.D. 90°C Net
(AWG/kcmil) Strands O.D. Ground (in) Weight
(in) Wires (lb/MFT)
CWCAPC-2-8* 8* 7 0.14 45 50 10 0.86 55 380
CWCAPC-2-6* 6* 7 0.18 45 50 6 0.96 75 500
CWCAPC-2-4* 4* 7 0.23 45 50 8 1.06 95 640
CWCAPC-2-2 2 7 0.27 45 50 6 1.16 130 865
CWCAPC-2-1 1 19 0.30 55 50 6 1.44 150 1110
CWCAPC-2-1/0 1/0 19 0.34 55 50 6 1.44 170 1265
CWCAPC-2-2/0 2/0 19 0.38 55 50 6 1.44 195 1460
CWCAPC-2-3/0 3/0 19 0.42 55 50 4 1.57 225 1790
CWCAPC-2-4/0 4/0 19+ 0.48 55 60 4 1.77 260 2155
CWCAPC-2-250 250 37 0.52 65 60 4 1.77 290 2450
CWCAPC-2-300 300 37 0.57 65 60 3 1.87 320 2865
CWCAPC-2-350 350 37 0.62 65 60 3 2.06 350 3265
CWCAPC-2-400 400 37 0.68 65 60 3 2.06 380 3615
CWCAPC-2-500 500 37 0.74 65 60 2 2.28 430 4410
CWCAPC-2-750 750 61 0.91 80 75 1 2.79 535 6505
ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
906 Information on this sheet subject to change without notice.
20160220 Copyright © 2018, American Wire Group, Inc.
Continuously Corrugated Welded Armored Power Cable
FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 3/C

Application
All cables produced to this specification are recognized by the NEC as 600 Volt Type MC-HL and are
suitable for use as described in the code. The conductor temperatures are rated for continuous oper-
ation of 90°C, for emergency overload of 130°C and for short circuit of 250°C. The cables meet the
requirements for application in NEC Class I, Class II and Class III, Div. 1 and 2, Hazardous Locations
covered under NEC articles 501, 502 and 503. The cables are intended for use in industrial applica-
tions where aluminum armor protection is necessary. The continuously welded sheath serves to
provide a completely moisture impervious barrier for the core as well as providing superior electro
static shielding characteristics. The cables may be used in wet or dry applications, installed in racks,
trays or aerially.
These cables have an overall jacket and can be direct buried in earth and buried in concrete.
Three conductor cables are manufactured in accordance with industry accepted practice of using
three symmetrically placed grounds making them advantageous for use in pulse-width modulated
cables and variable frequency drive applications.

Construction
This specification covers single and multi-conductor power cables insulated with flame retardant
crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and
the assembly are encased in a moisture impervious continuously welded corrugated aluminum
armor, and covered with a protective jacket overall. Three conductor type cables are constructed for
VFD applications.
Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements of
ASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM
B496.
Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concen-
trically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant govern-
ing specification.
Conductor Coding - Phase identification is provided by number code on each insulated conductor.
Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3
Copper Conductor
conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied con-
XLP Insulation
centric wires for single conductor cables. The total ground wire cross section in all cases meets the
minimum UL requirements for ground size.
Filters
Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers

ARMORED CABLES
Copper Ground Wire
make the cable round. a binder tape is applied.
Binder Tape
CorrugatedArmor
Armor - Over the taped assembly there is continuously welded corrugated aluminum armor.
PVC Jacket Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin
jacket is extruded for a tight fit over the interlocked armor.

Specifications
• National Fire Protection Association (NFPA 70) National Electric Code (NEC)
• UL 1569 Metal Clad Cables
• UL 44 Thermoset-Insulated Wires and Cables
• ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables
• IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies
(70,000 BTU)
• ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU)
• Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables.
• Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables.
• Listed by ULAs Type MC-HL per Standard UL 1569 Metal-Clad Cables.
• Listed by ULAs Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202.
Options
• Custom ground sizes
• CPE jacket.
Notes
**Based on single cable in uncovered cable tray at 30°C ambient temperature per NEC. For other
installations refer to the NEC.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 907
Copyright © 2018, AAmerican Wire Group, Inc. 20160220
Continuously Corrugated Welded Armored Power Cable
FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 3/C

Item # Conductor Conductor Conductor Insulation Jacket No. xAWG Approximate Ampacity** Approximate
Size No. of Nominal (mil) (mil) Copper O.D. 90°C Net
(AWG/kcmil) Strands O.D. Ground (in) Weight
(in) Wires (lb/MFT)
CWCAPC-3-8* 8* 7 0.14 45 50 3 x 14 0.91 55 465
CWCAPC-3-6* 6* 7 0.18 45 50 3 x 12 1.01 75 615
CWCAPC-3-4* 4* 7 0.23 45 50 3 x 12 1.11 97 810
CWCAPC-3-2 2 7 0.27 45 50 3 x 10 1.44 130 1205
CWCAPC-3-1 1 19 0.30 55 50 3 x 10 1.44 150 1415
CWCAPC-3-1/0 1/0 19 0.34 55 50 3 x 10 1.44 170 1645
CWCAPC-3-2/0 2/0 19 0.38 55 50 3 x 10 1.57 195 1965
CWCAPC-3-3/0 3/0 19 0.42 55 50 3x8 1.57 225 2375
CWCAPC-3-4/0 4/0 19 0.48 55 60 3x8 1.77 260 2880
CWCAPC-3-250 250 37 0.52 65 60 3x8 1.87 290 3340
CWCAPC-3-350 350 37 0.62 65 60 3x6 2.28 350 4520
CWCAPC-3-400 400 37 0.66 65 60 3x6 2.28 375 5070
CWCAPC-3-500 500 37 0.74 65 75 3x6 2.58 430 6260
CWCAPC-3-750 750 61 0.91 80 75 3x4 3.08 535 9100
CWCAPC-3-1000* 1000* 61 1.12 80 85 3x4 3.33 615 11965
ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
907 Information on this sheet subject to change without notice.
20160220 Copyright © 2018, American Wire Group, Inc.
Continuously Corrugated Welded Armored Power Cable
FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 4/C

Application
All cables produced to this specification are recognized by the NECAs 600 Volt Type MC-HL and are
suitable for use as described in the code. The conductor temperatures are rated for continuous oper-
ation of 90°C, for emergency overload of 130°C and for short circuit of 250°C. The cables meet the
requirements for application in NEC Class I, Class II and Class III, Div. 1 and 2, Hazardous Locations
covered under NEC articles 501, 502 and 503. The cables are intended for use in industrial applica-
tions where aluminum armor protection is necessary. The continuously welded sheath serves to
provide a completely moisture impervious barrier for the core as well as providing superior electro
static shielding characteristics. The cables may be used in wet or dry applications, installed in racks,
trays or aerially.
These cables have an overall jacket and can be direct buried in earth and buried in concrete.
Three conductor cables are manufactured in accordance with industry accepted practice of using
three symmetrically placed grounds making them advantageous for use in pulse-width modulated
cables and variable frequency drive applications.

Construction
This specification covers single and multi-conductor power cables insulated with flame retardant
crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and
the assembly are encased in a moisture impervious continuously welded corrugated aluminum
armor, and covered with a protective jacket overall. Three conductor type cables are constructed for
VFD applications.
Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements of
ASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM
B496.
Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concen-
trically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant govern-
ing specification.
Conductor Coding - Phase identification is provided by number code on each insulated conductor.
Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3
Copper Conductor conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied con-
XLP Insulation centric wires for single conductor cables. The total ground wire cross section in all cases meets the
Filters minimum UL requirements for ground size.
Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers

ARMORED CABLES
Copper Ground Wire
Binder Tape make the cable round. A binder tape is applied.
CorrugatedArmor Armor - Over the taped assembly there is continuously welded corrugated aluminum armor.
PVC Jacket Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin
jacket is extruded for a tight fit over the interlocked armor.

Specifications
• National Fire Protection Association (NFPA 70) National Electric Code (NEC)
• UL 1569 Metal Clad Cables
• UL 44 Thermoset-Insulated Wires and Cables
• ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables
• IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies
(70,000 BTU)
• ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU)
• Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables.
• Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables.
• Listed by ULAs Type MC-HL per Standard UL 1569 Metal-Clad Cables.
• Listed by ULAs Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202.
Options
• Custom ground sizes
• CPE jacket.
Notes
**Based on single cable in uncovered cable tray at 30°C ambient temperature per NEC. For other in-
stallations refer to the NEC.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 908
Copyright © 2018, American Wire Group, Inc. 20160220
Continuously Corrugated Welded Armored Power Cable
FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 4/C

Item # Conductor Conductor Conductor Insulation Jacket No. xAWG Approximate Ampacity** Approximate
Size No. of Nominal (mil) (mil) Copper O.D. 90°C Net
(AWG/kcmil) Strands O.D. Ground (in) Weight
(in) Wires (lb/MFT)
CWCAPC-4-2 2 7 0.27 45 50 6 1.44 104 1440
CWCAPC-4-1 1 19 0.30 55 50 6 1.44 120 1705
CWCAPC-4-1/0 1/0 19 0.34 55 50 6 1.57 136 2045
CWCAPC-4-2/0 2/0 19 0.38 55 60 6 1.77 156 2480
CWCAPC-4-3/0 3/0 19 0.42 55 60 4 1.77 180 3000
CWCAPC-4-4/0 4/0 19 0.48 55 60 4 1.87 208 3620
CWCAPC-4-250 250 37 0.52 65 60 4 2.06 232 4240
CWCAPC-3-1/0 1/0 19 0.34 55 50 3 x 10 1.44 170 1645
CWCAPC-3-2/0 2/0 19 0.38 55 50 3 x 10 1.57 195 1965
CWCAPC-3-3/0 3/0 19 0.42 55 50 3x8 1.57 225 2375
CWCAPC-3-4/0 4/0 19 0.48 55 60 3x8 1.77 260 2880
CWCAPC-3-250 250 37 0.52 65 60 3x8 1.87 290 3340
CWCAPC-3-350 350 37 0.62 65 60 3x6 2.28 350 4520
CWCAPC-3-400 400 37 0.66 65 60 3x6 2.28 375 5070
CWCAPC-3-500 500 37 0.74 65 75 3x6 2.58 430 6260
CWCAPC-3-750 750 61 0.91 80 75 3x4 3.08 535 9100
CWCAPC-3-1000* 1000* 61 1.12 80 85 3x4 3.33 615 11965
ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
908 Information on this sheet subject to change without notice.
20160220 Copyright © 2018, American Wire Group, Inc.
Continuously Corrugated Welded Armored Power Cable
FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 5/C

Application
All cables produced to this specification are recognized by the NEC as 600 Volt Type MC-HL and are
suitable for use as described in the code. The conductor temperatures are rated for continuous oper-
ation of 90°C, for emergency overload of 130°C and for short circuit of 250°C. The cables meet the
requirements for application in NEC Class I, Class II and Class III, Div. 1 and 2, Hazardous Locations
covered under NEC articles 501, 502 and 503. The cables are intended for use in industrial applica-
tions where aluminum armor protection is necessary. The continuously welded sheath serves to
provide a completely moisture impervious barrier for the core as well as providing superior electro
static shielding characteristics. The cables may be used in wet or dry applications, installed in racks,
trays or aerially.
These cables have an overall jacket and can be direct buried in earth and buried in concrete.
Three conductor cables are manufactured in accordance with industry accepted practice of using
three symmetrically placed grounds making them advantageous for use in pulse-width modulated
cables and variable frequency drive applications.

Construction
This specification covers single and multi-conductor power cables insulated with flame retardant
crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and
the assembly are encased in a moisture impervious continuously welded corrugated aluminum
armor, and covered with a protective jacket overall. Three conductor type cables are constructed for
VFD applications.
Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements of
ASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM
B496.
Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concen-
trically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant govern-
ing specification.
Conductor Coding - Phase identification is provided by number code on each insulated conductor.
Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3
Copper Conductor conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied con-
XLP Insulation centric wires for single conductor cables. The total ground wire cross section in all cases meets the
Copper Ground Wire minimum UL requirements for ground size.
Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers

ARMORED CABLES
Filters
Binder Tape make the cable round. A binder tape is applied.
CorrugatedArmor Armor - Over the taped assembly there is continuously welded corrugated aluminum armor.
PVC Jacket Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin
jacket is extruded for a tight fit over the interlocked armor.

Specifications
• National Fire Protection Association (NFPA 70) National Electric Code (NEC)
• UL 1569 Metal Clad Cables
• UL 44 Thermoset-Insulated Wires and Cables
• ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables
• IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies
(70,000 BTU)
• ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU)
• Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables.
• Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables.
• Listed by ULAs Type MC-HL per Standard UL 1569 Metal-Clad Cables.
• Listed by ULAs Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202.
Options
• Custom ground sizes
• CPE jacket.
Notes
**Based on single cable in uncovered cable tray at 30°C ambient temperature per NEC. For other in-
stallations refer to the NEC.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 909
Copyright © 2018, American Wire Group, Inc. 20160220
Continuously Corrugated Welded Armored Power Cable
FR-XLP Insulation (XHHW-2), 600V/1kV
Type MC-HL 5/C

Item # Conductor Conductor Conductor Insulation Jacket No. xAWG Approximate Ampacity** Approximate
Size No. of Nominal (mil) (mil) Copper O.D. 90°C Net
(AWG/kcmil) Strands O.D. Ground (in) Weight
(in) Wires (lb/MFT)
CWCAPC-5-8* 8* 7 0.14 45 50 10 1.06 44 700
CWCAPC-5-6* 6* 7 0.18 45 50 8 1.14 60 855
CWCAPC-5-4* 4* 7 0.23 45 50 8 1.44 88 1235
CWCAPC-5-2 2 7 0.27 45 50 6 1.44 104 1685
CWCAPC-5-1 1 19 0.30 55 50 6 1.57 120 2055
CWCAPC-5-1/0 1/0 19 0.34 55 60 6 1.77 136 2490
CWCAPC-5-2/0 2/0 19 0.38 55 60 6 1.77 156 2960
CWCAPC-5-3/0 3/0 19 0.42 55 60 4 1.87 180 3625
CWCAPC-5-4/0 4/0 19 0.48 55 60 4 2.06 208 4420
CWCAPC-5-250 250 37 0.52 65 60 4 2.28 232 5190
CWCAPC-5-300 300 37 0.57 65 75 3 2.58 256 6245
CWCAPC-5-350 350 37 0.62 65 75 3 2.58 280 7090
ARMORED CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
909 Information on this sheet subject to change without notice.
20160220 Copyright © 2018, American Wire Group, Inc.
UL Type MC Copper Conductor
with Ground PVC Jacket
600V

Applications
MC Cable is approved for use in many applications including direct burial, use in cable tray and out-
door exposure. The PVC jacket is free of harmful heavy metals in compliance with RoHS, Directive
2002/95/EC.
• Run from the combiner box to the inverter
• Suitable for rooftop solar applications
• Outdoors
• In wet locations (Type XHHW-2 , or RHW-2 conductors)
• Direct buried
• Encased in concrete
• Hazardous locations
• Strong, but lightweight alloy armor resists damage
• Suitable for wet locations, direct burial, encased in concrete and other uses per the NEC
• More flexible than conduit
• Factory tested engineered product that protects conductors from damage during installation
• Meets or exceeds requirements of the NEC, as well as applicable UL Standards
Construction
Stranded soft drawn copper conductor. Flame retardant thermoset crosslinked polyethylene (XLPE)
insulation Type XHHW-2 conductors rated for wet or dry locations at temperatures not to exceed
90ºC. Grounding is one bare copper stranded conductor, except for sizes 14AWG through 1AWG
contain a green insulated grounding conductor. Phase and grounding conductors are cabled to-
gether with binder tape. aluminum interlocked armor, applied over the binder tape and a longitudi-
nal marker tape, for ID, when unjacketed. Black sunlight resistant and flame retardant polyvinyl
chloride (PVC) compound jacket. Special constructions available upon request.

Standards
• Underwriters Laboratories Standards UL-44
• Class B stranding, per ASTM B 801
• UL-1569 for Type MC
• Federal Specification A-A59544
• IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test
• ICEA T-29-520 (210,000 Btu/hr) Flame Test, and the National Electrical Code (NEC)
• Single conductors are rated XHHW-2 600V, and CT Use 1/0AWG and larger.

ARMORED CABLES
• Additional UL Type PV available upon request.
• Aluminum armor is rated for Direct Burial, using 6AWG and larger conductors, with overall jacket
Notes
Ampacities are based on Table 310.15(B)(16) of the NEC.
* Ampacities shown are for general use as specified by the NEC, Section 310.15. For equipment
marked for use at higher temperatures, the conductor ampacity shall be limited to the following
per NEC 110.14(C):
• 60°C when terminated to equipment for circuits rated 100 amperes or less or marked for size
14AWG through 1AWG conductor.
• 75°C when terminated to equipment for circuits rated over 100 amperes or marked for conduc-
tors larger than 1AWG.
• 90°C for ampacity derating purposes.
When the neutral is considered current-carrying conductor, the ampacity of 4/C cables shall be re-
duced by a factor of 0.80 per NEC 310.15(B)(2)(a). The above data is approximate and subject to nor-
mal manufacturing tolerances.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 910
Copyright © 2018, American Wire Group, Inc. 20160220
UL Type MC Copper Conductor
with Ground PVC Jacket
600V

Item # Conductor No. of Green Outside Outside Jacket Approximate Allowable Allowable
Size Conductors Ground Diameter Diameter Thickness Net Ampacity Ampacity
(AWG/kcmil) Over Over Weight 75°C 90°C
Armor Jacket (lb/MFT) (Amps) (Amps)
14-02AIAWG 14 2 14AWG 0.464 0.564 0.05 191 15 15
14-03AIAWG 14 3 14AWG 0.498 0.700 0.05 219 15 15
14-04AIAWG 14 4 14AWG 0.536 0.737 0.05 249 15 15
12-02AIAWG 12 2 12AWG 0.503 0.705 0.05 227 20 20
12-03AIAWG 12 3 12AWG 0.542 0.747 0.05 265 20 20
12-04AIAWG 12 4 12AWG 0.584 0.786 0.05 304 20 20
10-02AIAWG 10 2 10AWG 0.553 0.754 0.05 282 30 30
10-03AIAWG 10 3 10AWG 0.597 0.799 0.05 335 30 30
10-04AIAWG 10 4 10AWG 0.646 0.848 0.05 389 30 30
8-02AIAWG 8 2 10AWG 0.677 0.892 0.05 427 50 55
8-03AIAWG 8 3 10AWG 0.757 0.957 0.05 524 50 55
8-04AIAWG 8 4 10AWG 0.834 1.021 0.05 618 50 55
6-02AIAWG 6 2 8AWG 0.791 0.974 0.05 566 65 75
6-03AIAWG 6 3 8AWG 0.884 1.045 0.05 700 65 75
6-04AIAWG 6 4 8AWG 0.974 1.123 0.05 832 65 75
4-03AIAWG 4 3 8AWG 0.964 1.161 0.05 900 85 95
4-04AIAWG 4 4 8AWG 1.070 1.250 0.05 1093 85 95
3-03AIAWG 3 3 6AWG 1.049 1.220 0.05 1075 100 115
3-04AIAWG 3 4 6AWG 1.164 1.329 0.05 1306 100 115
2-03AIAWG 2 3 6AWG 1.103 1.306 0.05 1234 115 130
2-04AIAWG 2 4 6AWG 1.228 1.415 0.05 1515 115 130
1-03AIAWG 1 3 6AWG 1.195 1.295 0.05 1162 130 145
Green Insulated
1-04AIAWG 1 4 6AWG 1.336 1.436 0.05 1477 130 145
Green Insulated
ARMORED CABLES

1/0-03AIAWG 1/0 3 6AWG Bare 1.213 1.313 0.05 1359 150 170
1/0-04AIAWG 1/0 4 6AWG Bare 1.335 1.435 0.05 1742 150 170
2/0-03AIAWG 2/0 3 6AWG Bare 1.308 1.408 0.05 1624 175 195
2/0-04AIAWG 2/0 4 6AWG Bare 1.441 1.541 0.05 2092 175 195
3/0-03AIAWG 3/0 3 4AWG Bare 1.415 1.515 0.05 2048 200 225
3/0-04AIAWG 3/0 4 4AWG Bare 1.562 1.682 0.06 2637 200 225
4/0-03AIAWG 4/0 3 4AWG Bare 1.536 1.656 0.06 2498 230 260
4/0-04AIAWG 4/0 4 4AWG Bare 1.697 1.817 0.06 3233 230 260
250-03AIAWG 250 3 4AWG Bare 1.648 1.768 0.06 2904 255 290
250-04AIAWG 250 4 4AWG Bare 1.822 1.942 0.06 3770 255 290
300-03AIAWG 300 3 3AWG Bare 1.760 1.880 0.06 3192 285 320
300-04AIAWG 300 4 3AWG Bare 1.948 2.068 0.06 4211 285 320
350-03AIAWG 350 3 3AWG Bare 1.862 1.982 0.06 3931 310 350
350-04AIAWG 350 4 3AWG Bare 2.061 2.181 0.06 5120 310 350
400-03AIAWG 400 3 3AWG Bare 1.956 2.076 0.06 4173 335 380
400-04AIAWG 400 4 3AWG Bare 2.167 2.287 0.06 5514 335 380
500-03AIAWG 500 3 2AWG Bare 2.131 2.251 0.06 5451 380 430
500-04AIAWG 500 4 2AWG Bare 2.363 2.513 0.075 7124 380 430
600-03AIAWG 600 3 2AWG Bare 2.411 2.561 0.075 6454 420 475
600-04AIAWG 600 4 2AWG Bare 2.677 2.827 0.075 8450 420 475
750-03AIAWG 750 3 1AWG Bare 2.631 2.781 0.075 8015 475 535
750-04AIAWG 750 4 1AWG Bare 2.923 3.073 0.075 10506 475 535

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
910 Information on this sheet subject to change without notice.
20160220 Copyright © 2018, American Wire Group, Inc.
CONTROL CABLES
Table of Contents

Control Cable FR-XLPE Insulated Conductors, PVC Jacket 600V.......................................501


Power Cable FR-XLPE Insulated Conductors, PVC Jacket 600V .......................................502
Control Cable FR-XLPE Insulated Conductors, CPE Jacket 600V ..................................... 503
Power Cable FR-XLPE Insulated Conductors, CPE Jacket 600V.........................................504
Control Cable FR-XLPE Insulated Conductors, Copper Shield, CPE Jacket 600V ............505
Control Cable FR-XLPE Insulated Conductors, XLPO Jacket 600V....................................506
Power Cable FR-XLPE Insulated Conductors, XLPO Jacket 600V......................................507
Control Cable FR-XLPE Insulated Conductors, Smooth Helical Bare Copper Shield,
XLPO Jacket 600V..................................................................................................................508
Control Cable FR-XLPE Insulated Conductors, Longitudinal Corrugated Bare Copper
Shield, XLPO Jacket 600V .....................................................................................................531
Control Cable FR-EPR Insulated Conductors, PVC Jacket 600V ........................................509
Power Cable FR-EPR Insulated Conductors, PVC Jacket 600V ........................................510
Control Cable FR-EPR Insulated Conductors, CPE Jacket 600V .........................................511
Power Cable FR-EPR Insulated Conductors, CPE Jacket 600V...........................................512
Control Cable FR-EPR Insulated Conductors, Copper Shield, CPE Jacket 600V...............513
20/10 Control Cable, PE/PVC Insulated Conductors, PVC Jacket 600V ..............................514
20/10 Control Cable, PE/PVC Insulated Conductors, Shield, PVC Jacket 600V .................515
THHN/PVC Tray Cable (Type TC) 600V
TFN, THWN or THHN Insulated Conductors, PVC Jacket 600V .......................................517
TFN, THWN or THHN Insulated Conductors, Shielded, Drain Wire, PVC Jacket 600V ..518
THWN or THHN Insulated Conductors with Ground, PVC Jacket 600V .........................519
Aluminum Three Conductor UL Type TC 600V .....................................................................529
Aluminum Four Conductor UL Type TC 600V ......................................................................530
Thermocouple Cable, EX, JX, KX, TX 600V .........................................................................520
IMSA 20-1 & ISMA 19-1 Traffic Control Cable 600V ............................................................521
IMSA 50-2 Tube Loop Lead-In Wire 600V .............................................................................522
IMSA 51-1 THHN Loop Detector Lead-In Wire 600V ............................................................523

CONTROL CABLES
IMSA 51-3 Loop Detector Wire 600V ....................................................................................524
IMSA 51-5 Inductant Loop Detector Cable 600V .................................................................525
IMSA Selection Guide ...........................................................................................................526
IMSA Color Code Chart .........................................................................................................527
IMSA Cable Shipping Weights — XHHX-2 & USE-2 ...........................................................528
Wire & Cable: Methods of Color Coding & Color Coding Charts ..........................................B

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 500
Copyright © 2018, American Wire Group, Inc. 20150508
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Control Cable
FR-XLPE Insulated Conductors
PVC Jacket, 600V

Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in wet or dry
locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also ap-
proved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC
cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in
air, in ducts or conduits, in tray or trough, and are suitable for direct burial.

Construction
Stranded uncoated copper conductors, 30 mils FR-XLPE flame-retardant cross-linked polyethylene
insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers
where necessary to make round, cable tape, PVC jacket overall, surface printed.

Standards
• Listed by UL as Type TC per Standard 1277 for Tray Cables.
• Cables UL listed for Direct Burial.
• Individual conductors pass UL VW-1 flame test.
• Individual conductors UL listed as Type XHHW-2.
• Overall jacket UL listed as Sunlight Resistant.
• Cables with grounding conductor UL listed for Open Wiring.
• Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test.
• Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
• Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables.
Notes
• Cables may be supplied with an insulated ground and marked “Open Wiring.”
• Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-
532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• Color Coding: ICEA Method 1, Table E-1
• EPR Insulation
• CPE, CSPE, LSOH Jackets
• Insulated ground wires or bare ground wires
• Overall copper tape shield
• Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 501
Copyright © 2018, American Wire Group, Inc. 20140110
Control Cable
FR-XLPE Insulated Conductors
PVC Jacket, 600V

Item # Number Size Number of Nominal Nominal Nominal Nominal Nominal Nominal Copper Copper Approx. Approx.
of AWG Strands Insulation Insulation Jacket Jacket Cable Cable Weight Weight Weight Weight
Conductors Thickness Thickness Thickness Thickness O.D. O.D. /MFT /km /MFT /km
(in) (mm) (in) (mm) (in) (mm) (lb) (kg) (lb) (kg))
14-R-PVC-2-FLAT 2 FLAT 14 7 0.030 0.76 0.045 1.14 .235x.370 5.97x9.40 25 37 62 92
14-R-PVC-2 2 14 7 0.030 0.76 0.045 1.14 0.365 9.270 25 37 73 109
14-R-PVC-3 3 14 7 0.030 0.76 0.045 1.14 0.390 9.910 40 59 93 138
14-R-PVC-4 4 14 7 0.030 0.76 0.045 1.14 0.425 10.800 53 79 116 173
14-R-PVC-5 5 14 7 0.030 0.76 0.045 1.14 0.465 11.810 66 99 140 208
14-R-PVC-7 7 14 7 0.030 0.76 0.045 1.14 0.590 14.990 93 138 176 262
14-R-PVC-9 9 14 7 0.030 0.76 0.060 1.52 0.620 15.750 119 177 245 365
14-R-PVC-12 12 14 7 0.030 0.76 0.060 1.52 0.680 17.270 159 237 302 449
14-R-PVC-19 19 14 7 0.030 0.76 0.060 1.52 0.800 20.320 252 375 460 685
14-R-PVC-25 25 14 7 0.030 0.76 0.080 2.03 0.985 25.020 323 481 641 954
14-R-PVC-30 30 14 7 0.030 0.76 0.080 2.03 1.050 26.670 387 571 740 1101
14-R-PVC-37 37 14 7 0.030 0.76 0.080 2.03 1.130 28.700 490 729 888 1322

12-R-PVC-2-FLAT 2 Flat 12 7/.0305 0.030 0.76 0.045 1.14 .245x.400 6.2 x10.16 40 60 86 128
12-R-PVC-2 2 12 7/.0305 0.030 0.76 0.045 1.14 0.410 10.410 41 61 96 143
12-R-PVC-3+GRND 3+Grnd 12 7/.0305 0.030 0.76 0.045 1.14 0.435 11.050 86 128 143 213
12-R-PVC-3 3 12 7/.0305 0.030 0.76 0.045 1.14 0.435 11.050 65 96 125 186
12-R-PVC-4 4 12 7/.0305 0.030 0.76 0.045 1.14 0.475 12.070 86 128 157 234
12-R-PVC-5 5 12 7/.0305 0.030 0.76 0.045 1.14 0.515 13.080 108 160 191 284
12-R-PVC-7 7 12 7/.0305 0.030 0.76 0.060 1.52 0.595 15.110 150 224 260 387
12-R-PVC-9 9 12 7/.0305 0.030 0.76 0.060 1.52 0.695 17.650 193 288 340 506
12-R-PVC-12 12 12 7/.0305 0.030 0.76 0.060 1.52 0.780 19.810 258 385 429 638
12-R-PVC-19 19 12 7/.0305 0.030 0.76 0.080 2.03 0.930 23.620 403 600 681 1013
12-R-PVC-25 25 12 7/.0305 0.030 0.76 0.080 2.03 1.095 27.810 515 767 885 1317
12-R-PVC-30 30 12 7/.0305 0.030 0.76 0.080 2.03 1.150 29.210 618 920 1005 1496
12-R-PVC-37 37 12 7/.0305 0.030 0.76 0.080 2.03 1.240 31.500 741 1103 1185 1764

10-R-PVC-2-FLAT 2 Flat 10 7/.0385 0.030 0.76 0.045 1.14 .290x.480 7.37x12.19 66 98 114 170
10-R-PVC-2 2 10 7/.0385 0.030 0.76 0.045 1.14 0.455 11.56 67 100 130 193
10-R-PVC-3+GRND 3+Grnd 10 7/.0385 0.030 0.76 0.045 1.14 0.485 12.32 135 200 201 299
10-R-PVC-3 3 10 7/.0385 0.030 0.76 0.045 1.14 0.485 12.32 101 150 173 257
CONTROL CABLES

10-R-PVC-4 4 10 7/.0385 0.030 0.76 0.06 1.52 0.515 13.08 135 200 236 351
10-R-PVC-5 5 10 7/.0385 0.030 0.76 0.06 1.52 0.615 15.62 167 249 287 427
10-R-PVC-7 7 10 7/.0385 0.030 0.76 0.06 1.52 0.67 17.02 234 349 371 552
10-R-PVC-9 9 10 7/.0385 0.030 0.76 0.06 1.52 0.785 19.94 295 440 479 713
10-R-PVC-12 12 10 7/.0385 0.030 0.76 0.08 2.03 0.895 22.73 402 598 644 958

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
501 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Power Cable
FR-XLPE Insulated Conductors
PVC Jacket, 600V

Applications
As flame-retardant three or four conductor power cables rated 600V, 90°C in wet or dry locations.
Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also
approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open
air, in ducts or conduits, in tray or trough, or direct buried.

Construction
Class B stranded uncoated copper conductor, XLPE cross-linked polyethylene insulation, surface
print phase identification. Three or four insulated conductors twisted with a Class B stranded un-
coated copper grounding conductor in two opposite valleys, suitable fillers, cable tape, PVC jacket
overall, surface printed.
Standards
• Listed by UL as Type TC per Standard 1277 for Tray Cables.
• Individual conductors UL listed as Type XHHW-2.
• Overall jacket UL listed as Sunlight Resistant.
• Cables pass UL and IEEE-383 ribbon burner flame tests.
• Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test (2 AWG and larger).
• Cables UL listed for Direct Burial.
• Cables UL listed for Open Wiring.
• Cables meet requirements of ICEA S-95-658/NEMA WC70.
• Color Code ICEA Method 4
Notes
• Ampacity in accordance with the National Electrical Code for cables in uncovered cable tray with-
out maintained spacing and for cables in raceway or directly buried; at the conductor temperature
indicated, in wet or dry locations, 30°C ambient temperature.
• Grounding conductor per UL Standard 1277 for Type TC Tray Cable
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• E1 or E2 color codes
• EPR Insulation
• CPE, CSPE, LSOH Jackets
• Insulated ground wires or bare ground wires
• Overall copper tape shield
• Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications..

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 502
Copyright © 2018, American Wire Group, Inc. 20140110
Power Cable
FR-XLPE Insulated Conductors
PVC Jacket, 600V

Item # Number of Size Conductor Ground Nominal Nominal Nominal Nominal Nominal Nominal Copper Copper Approx. Approx.
Conductors AWG Strand Wire Insulation Insulation Jacket Jacket Cable Cable Weight Weight Weight Weight
Size Thickness Thickness Thickness Thickness O.D. O.D. /MFT /km /MFT /km
AWG (in) (mm) (in) (mm) (in) (mm) (lb) (kg) (lb) (kg)
3RXLP-14 3 14 7/.0242 14 0.0300 0.76 0.05 1.14 0.425 10.80 53 79 116 173
3RXLP-12 3 12 7/.0305 12 0.0300 0.76 0.05 1.14 0.475 12.07 86 128 157 234
3RXLP-10 3 10 7/.0385 10 0.0300 0.76 0.06 1.52 0.515 13.08 135 200 236 351

3RXLP-8 3 8 7/.0486 10 0.045 1.14 0.06 1.52 0.640 16.26 190 283 314 467
4RXLP-8 4 8 7/.0486 10 0.045 1.14 0.06 1.52 0.705 17.91 242 360 385 573

3RXLP-6 3 6 7/.0612 8 0.045 1.14 0.06 1.52 0.720 18.29 301 448 445 662
4RXLP-6 4 6 7/.0612 8 0.045 1.14 0.06 1.52 0.790 20.07 384 571 558 830

3RXLP-4 3 4 7/.0772 8 0.045 1.14 0.08 2.03 0.875 22.23 448 667 653 972
4RXLP-4 4 4 7/.0772 8 0.045 1.14 0.08 2.03 0.950 24.13 578 862 820 1220

3RXLP-2 3 2 7/.0974 6 0.045 1.14 0.08 2.03 1.000 25.40 716 1066 964 1435
4RXLP-2 4 2 7/.0974 6 0.045 1.14 0.08 2.03 1.095 27.81 919 1368 1214 1807

3RXLP-1 3 1 19/.0664 6 0.055 1.40 0.08 2.03 1.120 28.45 872 1298 1199 1784
4RXLP-1 4 1 19/.0664 6 0.055 1.40 0.08 2.03 1.235 31.37 1136 1691 1704 2536

3RXLP-1/0 3 1/0 19/.0745 6 0.055 1.40 0.08 2.03 1.215 30.86 1081 1609 1414 2104
4RXLP-1/0 4 1/0 19/.0745 6 0.055 1.40 0.08 2.03 1.340 34.04 1413 2103 1825 2716

3RXLP-2/0 3 2/0 19/.0837 6 0.055 1.40 0.08 2.03 1.310 33.27 1341 1996 1706 2539
4RXLP-2/0 4 2/0 19/.0837 6 0.055 1.40 0.08 2.03 1.450 36.83 1760 2619 2223 3308

3RXLP-3/0 3 3/0 19/.0940 4 0.055 1.40 0.08 2.03 1.420 36.07 1717 2555 2437 3627
4RXLP-3/0 4 3/0 19/.0940 4 0.055 1.40 0.08 2.03 1.570 39.88 2245 3341 3123 4648

3RXLP-4/0 3 4/0 19/.1055 4 0.055 1.40 0.08 2.03 1.540 39.12 2132 3173 2600 3869
4RXLP-4/0 4 4/0 19/.1055 4 0.055 1.40 0.11 2.79 1.765 44.83 2796 4161 3444 5125

3RXLP-250 3 250 37/.0822 4 0.065 1.65 0.11 2.79 1.750 44.45 2494 3712 3142 4676
CONTROL CABLES

4RXLP-250 4 250 37/.0822 4 0.065 1.65 0.11 2.79 1.930 49.02 3282 4884 4048 6024

3RXLP-350 3 350 37/.0973 3 0.065 1.65 0.11 2.79 1.970 50.04 3474 5170 4230 6295
4RXLP-350 4 350 37/.0973 3 0.065 1.65 0.11 2.79 2.180 55.37 4577 6811 5470 8140

3RXLP-500 3 500 37/.1162 2 0.065 1.65 0.11 2.79 2.250 57.15 4938 7349 5829 8675
4RXLP-500 4 500 37/.1162 2 0.065 1.65 0.11 2.79 2.475 62.87 6509 9687 7579 11279

3RXLP-750 3 750 61/.1109 1 0.080 2.03 0.14 3.56 2.810 71.37 7278 10831 9101 13544
4RXLP-750 4 750 61/.1109 1 0.080 2.03 0.14 3.56 3.115 79.12 9712 14453 11746 17480

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
502 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Control Cable
FR-XLPE Insulated Conductors
CPE Jacket, 600V

Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in wet or dry
locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also ap-
proved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC
cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in
air, in ducts or conduits, in tray or trough, and are suitable for direct burial.

Construction
Stranded uncoated copper conductors, 30 mils FR-XLPE flame-retardant cross-linked polyethylene
insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers
where necessary to make round, cable tape, CPE jacket overall, surface printed.

Standards
• Listed by UL as Type TC per Standard 1277 for Tray Cables.
• Cables UL listed for Direct Burial.
• Individual conductors pass UL VW-1 flame test.
• Individual conductors UL listed as Type XHHW-2.
• Overall jacket UL listed as Sunlight Resistant.
• Cables with grounding conductor UL listed for Open Wiring.
• Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test.
• Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
• Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables.
• Color Code ICEA Method 4.
Notes
• Cables may be supplied with an insulated ground and marked “Open Wiring.”
• Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-
532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• Color Coding: ICEA Method 1, Table E-1
• EPR Insulation
• PVC, CSPE, LSOH Jackets
• Insulated ground wires or bare ground wires
• Overall copper tape shield
• Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 503
Copyright © 2018, American Wire Group, Inc. 20140110
Control Cable
FR-XLPE Insulated Conductors
CPE Jacket, 600V

Item # Number of Size Number of Nominal Nominal Nominal Nominal Nominal Nominal Copper Copper Approx. Approx.
Conductors AWG Strands Insulation Insulation Jacket Jacket Cable Cable Weight Weight Weight Weight
Thickness Thickness Thickness Thickness O.D. O.D. /MFT /km /MFT /km
(in) (mm) (in) (mm) (in) (mm) (lb) (kg) (lb) (kg)
14-R-CPE-2-FLAT 2 FLAT 14 7 0.030 0.76 0.045 1.14 .235x.370 5.97x9.40 25 37 62 92
14-R-CPE-2 2 14 7 0.030 0.76 0.045 1.14 0.365 9.270 25 37 73 109
14-R-CPE-3 3 14 7 0.030 0.76 0.045 1.14 0.390 9.910 40 59 93 138
14-R-CPE-4 4 14 7 0.030 0.76 0.045 1.14 0.425 10.800 53 79 116 173
14-R-CPE-5 5 14 7 0.030 0.76 0.045 1.14 0.465 11.810 66 99 140 208
14-R-CPE-7 7 14 7 0.030 0.76 0.045 1.14 0.590 14.990 93 138 176 262
14-R-CPE-9 9 14 7 0.030 0.76 0.060 1.52 0.620 15.750 119 177 245 365
14-R-CPE-12 12 14 7 0.030 0.76 0.060 1.52 0.680 17.270 159 237 302 449
14-R-CPE-19 19 14 7 0.030 0.76 0.060 1.52 0.800 20.320 252 375 460 685
14-R-CPE-25 25 14 7 0.030 0.76 0.080 2.03 0.985 25.020 323 481 641 954
14-R-CPE-30 30 14 7 0.030 0.76 0.080 2.03 1.050 26.670 387 571 740 1101
14-R-CPE-37 37 14 7 0.030 0.76 0.080 2.03 1.130 28.700 490 729 888 1322

12-R-CPE-2-FLAT 2 FLAT 12 7/.0305 0.030 0.76 0.045 1.14 .245x.400 6.22x10.16 40 60 86 128
12-R-CPE-2 2 12 7/.0305 0.030 0.76 0.045 1.14 0.410 10.410 41 61 96 143
12-R-CPE-3+GRND 3+Grnd 12 7/.0305 0.030 0.76 0.045 1.14 0.435 11.050 86 128 143 213
12-R-CPE-3 3 12 7/.0305 0.030 0.76 0.045 1.14 0.435 11.050 65 96 125 186
12-R-CPE-4 4 12 7/.0305 0.030 0.76 0.045 1.14 0.475 12.070 86 128 157 234
12-R-CPE-5 5 12 7/.0305 0.030 0.76 0.045 1.14 0.515 13.080 108 160 191 284
12-R-CPE-7 7 12 7/.0305 0.030 0.76 0.060 1.52 0.595 15.110 150 224 260 387
12-R-CPE-9 9 12 7/.0305 0.030 0.76 0.060 1.52 0.695 17.650 193 288 340 506
12-R-CPE-12 12 12 7/.0305 0.030 0.76 0.060 1.52 0.780 19.810 258 385 429 638
12-R-CPE-19 19 12 7/.0305 0.030 0.76 0.080 2.03 0.930 23.620 403 600 681 1013
12-R-CPE-25 25 12 7/.0305 0.030 0.76 0.080 2.03 1.095 27.810 515 767 885 1317
12-R-CPE-30 30 12 7/.0305 0.030 0.76 0.080 2.03 1.150 29.210 618 920 1005 1496
12-R-CPE-37 37 12 7/.0305 0.030 0.76 0.080 2.03 1.240 31.500 741 1103 1185 1764

10-R-CPE-2-FLAT 2 FLAT 10 7/.0385 0.030 0.76 0.045 1.14 .290x.480 7.37x12.19 66 98 114 170
10-R-CPE-2 2 10 7/.0385 0.030 0.76 0.045 1.14 0.455 11.560 67 100 130 193
10-R-CPE-3+GRND 3+Grnd 10 7/.0385 0.030 0.76 0.045 1.14 0.485 12.320 135 200 201 299
10-R-CPE-3 3 10 7/.0385 0.030 0.76 0.045 1.14 0.485 12.320 101 150 173 257
CONTROL CABLES

10-R-CPE-4 4 10 7/.0385 0.030 0.76 0.060 1.52 0.515 13.080 135 200 236 351
10-R-CPE-5 5 10 7/.0385 0.030 0.76 0.060 1.52 0.615 15.620 167 249 287 427
10-R-CPE-7 7 10 7/.0385 0.030 0.76 0.060 1.52 0.670 17.020 234 349 371 552
10-R-CPE-9 9 10 7/.0385 0.030 0.76 0.060 1.52 0.785 19.940 295 440 479 713
10-R-CPE-12 12 10 7/.0385 0.030 0.76 0.080 2.03 0.895 22.730 402 598 644 958

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
503 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Power Cable
FR-XLPE Insulated Conductors
CPE Jacket, 600V

Applications
As flame-retardant three or four conductor power cables rated 600V, 90°C in wet or dry locations.
Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also
approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open
air, in ducts or conduits, in tray or trough, or direct buried.

Construction
Class B stranded uncoated copper conductor, FR-XLPE flame-retardant cross-linked polyethylene in-
sulation, surface print phase identification. Three or four insulated conductors twisted with a Class B
stranded uncoated copper grounding conductor and suitable fillers, cable tape, CPE jacket overall,
surface printed.

Standards
• Listed by UL as Type TC per Standard 1277 for Tray Cables.
• Individual conductors UL listed as Type XHHW-2.
• Individual conductors pass UL VW-1 flame test.
• Overall jacket UL listed as Sunlight Resistant and Oil Resistant II.
• Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test.
• Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
• Cables UL listed for Direct Burial.
• Cables UL listed for Open Wiring.
• Cables meet requirements of ICEA S-95-658/NEMA WC70.
• Color Code ICEA Method 4.
Notes
• Ampacity in accordance with the National Electrical Code for cables in uncovered cable tray with-
out maintained spacing and for cables in raceway or directly buried; at the conductor temperature
indicated, in wet or dry locations, 30°C ambient temperature.
• Grounding conductor per UL Standard 1277 for Type TC Tray Cable.
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• E1 or E2 color codes
• EPR Insulation
• PVC, CSPE, LSOH Jackets
• Insulated ground wires or bare ground wires
• Overall copper tape shield, Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 504
Copyright © 2018, American Wire Group, Inc. 20140110
Power Cable
FR-XLPE Insulated Conductors
CPE Jacket, 600V

Item # Number of Size Conductor Ground Nominal Nominal Nominal Nominal Nominal Nominal Copper Copper Approx. Approx.
Conductors AWG Strand Wire Insulation Insulation Jacket Jacket Cable Cable Weight Weight Weight Weight
Size Thickness Thickness Thickness Thickness O.D. O.D. /MFT /km /MFT /km
AWG (in) (mm) (in) (mm) (in) (mm) (lb) (kg) (lb) (kg)
3EXLP-14 3 14 7/.0242 14 0.0300 0.76 0.05 1.14 0.425 10.80 53 79 116 173
3EXLP-12 3 12 7/.0305 12 0.0300 0.76 0.05 1.14 0.475 12.07 86 128 157 234
3EXLP-10 3 10 7/.0385 10 0.0300 0.76 0.06 1.52 0.515 13.08 135 200 236 351

3EXLP-8 3 8 7/.0486 10 0.045 1.14 0.06 1.52 0.640 16.26 190 283 314 467
4EXLP-8 4 8 7/.0486 10 0.045 1.14 0.06 1.52 0.705 17.91 242 360 385 573

3EXLP-6 3 6 7/.0612 8 0.045 1.14 0.06 1.52 0.720 18.29 301 448 445 662
4EXLP-6 4 6 7/.0612 8 0.045 1.14 0.06 1.52 0.790 20.07 384 571 558 830

3EXLP-4 3 4 7/.0772 8 0.045 1.14 0.08 2.03 0.875 22.23 448 667 653 972
4EXLP-4 4 4 7/.0772 8 0.045 1.14 0.08 2.03 0.950 24.13 578 862 820 1220

3EXLP-2 3 2 7/.0974 6 0.045 1.14 0.08 2.03 1.000 25.40 716 1066 964 1435
4EXLP-2 4 2 7/.0974 6 0.045 1.14 0.08 2.03 1.095 27.81 919 1368 1214 1807

3EXLP-1 3 1 19/.0664 6 0.055 1.40 0.08 2.03 1.120 28.45 872 1298 1199 1784
4EXLP-1 4 1 19/.0664 6 0.055 1.40 0.08 2.03 1.235 31.37 1136 1691 1704 2536

3EXLP-1/0 3 1/0 19/.0745 6 0.055 1.40 0.08 2.03 1.215 30.86 1081 1609 1414 2104
4EXLP-1/0 4 1/0 19/.0745 6 0.055 1.40 0.08 2.03 1.340 34.04 1413 2103 1825 2716

3EXLP-2/0 3 2/0 19/.0837 6 0.055 1.40 0.08 2.03 1.310 33.27 1341 1996 1706 2539
4EXLP-2/0 4 2/0 19/.0837 6 0.055 1.40 0.08 2.03 1.450 36.83 1760 2619 2223 3308

3EXLP-3/0 3 3/0 19/.0940 4 0.055 1.40 0.08 2.03 1.420 36.07 1717 2555 2437 3627
4EXLP-3/0 4 3/0 19/.0940 4 0.055 1.40 0.08 2.03 1.570 39.88 2245 3341 3123 4648

3EXLP-4/0 3 4/0 19/.1055 4 0.055 1.40 0.08 2.03 1.540 39.12 2132 3173 2600 3869
4EXLP-4/0 4 4/0 19/.1055 4 0.055 1.40 0.11 2.79 1.765 44.83 2796 4161 3444 5125

3EXLP-250 3 250 37/.0822 4 0.065 1.65 0.11 2.79 1.750 44.45 2494 3712 3142 4676
CONTROL CABLES

4EXLP-250 4 250 37/.0822 4 0.065 1.65 0.11 2.79 1.930 49.02 3282 4884 4048 6024

3EXLP-350 3 350 37/.0973 3 0.065 1.65 0.11 2.79 1.970 50.04 3474 5170 4230 6295
4EXLP-350 4 350 37/.0973 3 0.065 1.65 0.11 2.79 2.180 55.37 4577 6811 5470 8140

3EXLP-500 3 500 37/.1162 2 0.065 1.65 0.11 2.79 2.250 57.15 4938 7349 5829 8675
4EXLP-500 4 500 37/.1162 2 0.065 1.65 0.11 2.79 2.475 62.87 6509 9687 7579 11279

3EXLP-750 3 750 61/.1109 1 0.080 2.03 0.14 3.56 2.810 71.37 7278 10831 9101 13544
4EXLP-750 4 750 61/.1109 1 0.080 2.03 0.14 3.56 3.115 79.12 9712 14453 11746 17480

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
504 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Control Cable
FR-XLPE Insulated Conductors
Copper Shield, CPE Jacket, 600V

Applications
Control or signal cable for important circuits in industrial plants and station control cable for electric
utilities where flame resistance is essential. Suitable for the operation and interconnection of pro-
tective devices; rated circuit voltage 600V; recommended for operation at 90°C maximum continu-
ous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or
conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL
requirements.

Construction
Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene
rubber (FR-EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1
color-coded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket
overall, surface printed.

Standards
• TC Type Tray Cable per Article 340 of the NEC.
• Individual conductors pass UL Standard 44 and the VW-1 vertical flame test.
• Individual conductors approved as Type XHHW.
•. Cables Pass IEEE-383 ribbon burner flame test.
• Overall jacket approved as Sunlight Resistant.
• Cables meet requirements of ICEA S-73-532, NEMA WC57 for control cables.
Notes
• Cables may be supplied with an insulated ground and marked “Open Wiring.”
• Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-
532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• Color Coding: ICEA Method 1, Table E-1
• EPR Insulation
• PVC, CSPE, LSOH Jackets
• Insulated ground wires or bare ground wires
• Overall copper tape shield
• Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 505
Copyright © 2018, American Wire Group, Inc. 20140110
Control Cable
FR-XLPE Insulated Conductors
Copper Shield, CPE Jacket, 600V

Item # Number of Conductor Conductor Overall Overall Approx.


Conductors Stranding Size mils Diameter Cable
AWG (in) Weight
/MFT
(lb)
14-402SH 2 7 14 45 0.40 120
14-403SH 3 7 14 45 0.42 145
14-404SH 4 7 14 45 0.45 180
14-405SH 5 7 14 45 0.49 230
14-406SH 6 7 14 60 0.53 275
14-407SH 7 7 14 60 0.60 275
14-408SH 8 7 14 60 0.70 305
14-409SH 9 7 14 60 N/A N/A
14-412SH 12 7 14 60 0.89 435
14-414SH 14 7 14 80 0.96 530
14-415SH 15 7 14 80 1.04 565
14-416SH 16 7 14 80 1.05 575
14-418SH 18 7 14 80 1.07 665
14-419SH 19 7 14 80 1.09 665
14-420SH 20 7 14 80 1.10 720
14-425SH 25 7 14 80 1.22 905
14-427SH 27 7 14 80 1.25 905
14-429SH 29 7 14 80 1.26 960
14-431SH 31 7 14 80 1.31 1090
14-432SH 32 7 14 80 1.34 1090
14-437SH 37 7 14 80 1.39 1165

12-452SH 2 12 7 45 0.49 155


12-453SH 3 12 7 45 0.54 185
12-454SH 4 12 7 60 0.62 245
12-455SH 5 12 7 60 0.67 295
12-456SH 6 12 7 60 0.70 340
12-457SH 7 12 7 60 0.73 340
12-458SH 8 12 7 60 0.86 395
12-462SH 12 12 7 80 0.95 610
12-464SH 14 12 7 80 1.04 690
CONTROL CABLES

12-465SH 15 12 7 80 1.20 770


12-466SH 16 12 7 80 1.22 780
12-468SH 18 12 7 80 1.25 865
12-469SH 19 12 7 80 1.25 865
12-470SH 20 12 7 80 1.31 940
12-475SH 25 12 7 80 1.39 1175
12-477SH 27 12 7 80 1.41 1200
12-479SH 29 12 7 80 1.42 1270
12-481SH 31 12 7 80 1.44 1425
12-482SH 32 12 7 80 1.47 1425
12-487SH 37 12 7 80 1.53 1545

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
505 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Control Cable
FR-XLPE Insulated Conductors
Copper Shield, CPE Jacket, 600V

Item # Number of Conductor Conductor Overall Overall Approx.


Conductors Stranding Size mils Diameter Cable
AWG (in) Weight
/MFT
(lb)
10-502SH 2 10 7 45 0.52 190
10-503SH 3 10 7 60 0.62 255
10-504SH 4 10 7 60 0.68 320
10-505SH 5 10 7 60 0.73 370
10-506SH 6 10 7 60 0.80 440
10-507SH 7 10 7 60 0.85 450
10-508SH 8 10 7 80 1.05 755
10-512SH 12 10 7 80 1.10 810
10-514SH 14 10 7 80 1.14 920
10-515SH 15 10 7 80 1.20 995
10-516SH 16 10 7 80 1.24 1020
10-518SH 18 10 7 80 1.27 1140
10-519SH 19 10 7 80 1.27 1155
10-520SH 20 10 7 80 1.34 1255
10-525SH 25 10 7 80 1.48 1600
10-527SH 27 10 7 80 1.52 1625
10-529SH 29 10 7 80 1.54 1730
10-531SH 31 10 7 80 1.60 1950
10-532SH 32 10 7 80 1.63 1950
10-537SH 37 10 7 80 1.70 2120
*Part numbers are for CPE jacketed cables only

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 505
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Control Cable
FR-XLPE Insulated Conductors
XLPO Jacket, 600V

Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in wet or dry
locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also ap-
proved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC
cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in
air, in ducts or conduits, in tray or trough, and are suitable for direct burial.

Construction
Stranded uncoated copper conductors, FR-XLPE flame-retardant cross-linked polyethylene insula-
tion, color coded, two conductors flat, three or more conductors twisted with suitable fillers where
necessary to make round, cable tape, XLPO jacket overall, surface printed.

Standards
• Listed by UL as Type TC per Standard 1277 for Tray Cables.
• Cables UL listed for Direct Burial.
• Individual conductors pass UL VW-1 flame test.
• Individual conductors UL listed as Type XHHW-2.
• Overall jacket UL listed as Sunlight Resistant.
• Cables with grounding conductor UL listed for Open Wiring.
• Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test.
• Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
• Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables.
Notes
• Cables may be supplied with an insulated ground and marked “Open Wiring.”
• Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-
532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• Color Coding: ICEA Method 1, Table E-1
• EPR Insulation
• PVC,CPE CSPE Jackets
• Insulated ground wires or bare ground wires
• Overall copper tape shield
• Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 506
Copyright © 2018, American Wire Group, Inc. 20140110
Control Cable
FR-XLPE Insulated Conductors
XLPO Jacket, 600V

Item # Number of Conductor Conductor Insulation Nominal Nominal Nominal Nominal Approximate Approximate
Conductors Size Stranding Thickness Jacket Jacket Cable Cable Cable Weight Cable Weight
AWG (in) Thickness Thickness O.D. O.D. /MFT /Km
(in) (mm) (in) (mm) (lb) (kg)
14-R-XLPO-2 2 14 7 .030 .045 1.1 .235 x .375 5.97 x 9.53 67 99
14-R-XLPO-3 3 14 7 .030 .045 1.1 0.400 10.2 102 151
14-R-XLPO-4 4 14 7 .030 .045 1.1 0.435 11.0 126 186
14-R-XLPO-5 5 14 7 .030 .045 1.1 0.475 12.1 150 222
14-R-XLPO-7 7 14 7 .030 .045 1.1 0.520 13.2 191 283
14-R-XLPO-9 9 14 7 .030 .060 1.5 0.650 16.5 274 406
14-R-XLPO-12 12 14 7 .030 .060 1.5 0.710 18.0 340 503
14-R-XLPO-16 16 14 7 .030 .060 1.5 0.790 20.1 433 641
14-R-XLPO-19 19 14 7 .030 .060 1.5 0.835 21.2 496 734
14-R-XLPO-26 26 14 7 .030 .080 2.0 1.040 26.4 685 1014
14-R-XLPO-30 30 14 7 .030 .080 2.0 1.075 27.3 762 1128
14-R-XLPO-37 37 14 7 .030 .080 2.0 1.155 29.3 915 1406

12-R-XLPO-2 2 12 7 .030 .045 1.1 .255 x .415 6.48 x 11.4 92 136


12-R-XLPO-3 3 12 7 .030 .045 1.1 0.440 11.2 131 194
12-R-XLPO-4 4 12 7 .030 .045 1.1 0.485 12.3 164 243
12-R-XLPO-5 5 12 7 .030 .045 1.1 0.530 13.5 202 299
12-R-XLPO-7 7 12 7 .030 .060 1.5 0.610 15.5 283 419
12-R-XLPO-9 9 12 7 .030 .060 1.5 0.715 18.2 357 528
12-R-XLPO-12 12 12 7 .030 .060 1.5 0.795 20.2 462 684
12-R-XLPO-16 16 12 7 .030 .080 2.0 0.930 23.6 620 918
12-R-XLPO-19 19 12 7 .030 .080 2.0 0.975 24.8 710 1051
12-R-XLPO-26 26 12 7 .030 .080 2.0 1.160 29.5 950 1406
12-R-XLPO-30 30 12 7 .030 .080 2.0 1.200 30.5 1065 1576
12-R-XLPO-37 37 12 7 .030 .080 2.0 1.300 33.0 1285 1902

10-R-XLPO-2 2 10 7 .030 .045 1.1 .280 x .465 7.11 x 11.8 121 179
10-R-XLPO-3 3 10 7 .030 .045 1.1 0.500 12.7 185 274
10-R-XLPO-4 4 10 7 .030 .060 1.5 0.575 14.6 257 380
10-R-XLPO-5 5 10 7 .030 .060 1.5 0.630 16.0 308 456
10-R-XLPO-7 7 10 7 .030 .060 1.5 0.690 17.5 397 588
10-R-XLPO-9 9 10 7 .030 .060 1.5 0.805 20.4 496 734
CONTROL CABLES

10-R-XLPO-12 12 10 7 .030 .080 2.0 0.935 23.7 661 978


Part numbers are for XLPE/XLPO jacketed cables only.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
506 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Power Cable
FR-XLPE Insulated Conductors
XLPO Jacket, 600V

Applications
Flame retardant control/power cable in free air, raceway and direct burial, for use in wet or dry loca-
tions. Rated at 90°C wet or dry. Permitted for Exposed Run use in accordance with NEC for 3 or
more conductors . Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC.
Sunlight-and weather-resistant. Meets cold bend test at -40°C.

Construction
8 AWG thru 750 kcmil annealed stranded copper conductors per ASTM B33. Class B uncoated cop-
per grounding conductor per ASTM B8. Flame-retardant FR-XLPE insulation, XLPO jacket, color-
coded per ICEA Method 1; Table E-1. Sizes 8 AWG and larger are color-coded per ICEA Method 4;
Individual conductors colored black with conductor number surface printed in contrasting ink

Standards
• Listed by UL as Type TC per Standard 1277 for Tray Cables.
• Cables UL listed for Direct Burial.
• Individual conductors pass UL 1581 VW-1 flame test.
• Individual conductors UL44 listed as Type XHHW-2.
• Overall jacket UL listed as Sunlight Resistant.
• Cables with grounding conductor UL listed for Open Wiring.
• Cables pass IEEE-383 ribbon burner flame test.
• Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
• Cables meet requirements of ICEA S-95-658, NEMA WC70.
• Cables meet requirements of ICEA T-29-520 AND CSA FT-4
• Color Code ICEA Method 4
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• E1 or E2 color codes
• FRXLP or EPR Insulations
• PVC, CPE, CSPE, Jackets
• Insulated ground wires or bare ground wires
• Overall copper tape shield
• Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 507
Copyright © 2018, American Wire Group, Inc. 20140110
Power Cable
FR-XLPE Insulated Conductors
XLPO Jacket, 600V

Item # Number of Conductor Conductor Ground Insulation Nominal Nominal Nominal Nominal Approx. Approx.
Conductors Size Stranding Wire Thickness Jacket Jacket Cable Cable Cable Wt. Cable Wt.
AWG Size (in) Thickness Thickness O.D. O.D. /MFT /Km
AWG (in) (mm) (in) (mm) (lb) (kg)
08-XLPO-2 2 8 7 - .045 .060 1.5 0.625 15.9 199 295
08-XLPO-3 3 8 7 - .045 .060 1.5 0.665 16.9 296 438
08-XLPO-3G 3+GRD 8 7 10 .045 .060 1.5 0.665 16.9 321 475
08-XLPO-4 4 8 7 - .045 .060 1.5 0.730 18.5 383 567

06-XLPO-2 2 6 7 - .045 .060 1.5 0.705 17.9 306 453


06-XLPO-3 3 6 7 - .045 .060 1.5 0.750 19.1 413 611
06-XLPO-3G 3+GRD 6 7 8 .045 .060 1.5 0.750 19.1 459 679
06-XLPO-4 4 6 7 - .045 .060 1.5 0.825 21.0 528 781

04-XLPO-2 2 4 7 - .045 .060 1.5 0.805 20.4 437 647


04-XLPO-3 3 4 7 - .045 .060 1.5 0.860 21.8 597 884
04-XLPO-3G 3+GRD 4 7 8 .045 .060 1.5 0.860 21.8 643 952
04-XLPO-4 4 4 7 - .045 .080 2.0 0.990 25.1 803 1188

02-XLPO-2 2 2 7 - .045 .080 2.0 0.975 24.8 672 1001


02-XLPO-3 3 2 7 - .045 .080 2.0 1.035 26.3 915 1352
02-XLPO-3G 3+GRD 2 7 6 .045 .080 2.0 1.035 26.3 991 1467
02-XLPO-4 4 2 7 - .045 .080 2.0 1.140 29.0 1175 1739

10-XLPO-3 3 1/0 19 - .055 .080 2.0 1.240 31.5 1399 2084


10-XLPO-3G 3+GRD 1/0 19 6 .055 .080 2.0 1.240 31.5 1471 2192
10-XLPO-4 4 1/0 19 - .055 .080 2.0 1.370 34.5 1794 2673

20-XLPO-3 3 2/0 19 - .055 .080 2.0 1.340 34.0 1707 2543


20-XLPO-3G 3+GRD 2/0 19 6 .055 .080 2.0 1.340 34.0 1778 2649
20-XLPO-4 4 2/0 19 - .055 .080 2.0 1.480 37.6 2203 3282

40-XLPO-3 3 4/0 19 - .055 .080 2.0 1.580 40.1 2578 3841


40-XLPO-3G 3+GRD 4/0 19 4 .055 .080 2.0 1.580 40.1 2734 4046
40-XLPO-4 4 4/0 19 - .055 .110 2.8 1.810 46.0 3455 5113

350-XLPO-3 3 350 37 - .065 .110 2.8 2.030 51.6 4251 6291


350-XLPO-3G 3+GRD 350 37 3 .065 .110 2.8 2.030 51.6 4385 6490
350-XLPO-4 4 350 37 - .065 .110 2.8 2.240 56.9 5505 8147

500-XLPO-3 3 500 37 - .065 .110 2.8 2.320 58.9 5869 8686


CONTROL CABLES

500-XLPO-3G 3+GRD 500 37 2 .065 .110 2.8 2.320 58.9 6092 9016
500-XLPO-4 4 500 37 - .065 .110 2.8 2.740 69.6 7668 11349

750-XLPO-3 3 750 61 - .080 .140 3.6 2.860 72.6 8730 12920


750-XLPO-3G 3+GRD 750 61 1 .080 .140 3.6 2.860 72.6 8976 13284

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
507 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Control Cable FR-XLPE Insulated Conductors
Smooth Helical Bare Copper Tape Shield,
Low Smoke Halogen Polyolefin XLPO Jacket, 600V

Applications
Control or signal cable for important circuits in industrial plants and station control cable for electric
utilities where flame resistance is essential. Suitable for the operation and interconnection of pro-
tective devices; rated circuit voltage 600V; recommended for operation at 90°C maximum continu-
ous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or
conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL
requirements.

Construction
Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene
rubber (FR-EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1
color-coded, conductors twisted with suitable fillers, helically applied copper tape shield, XLPO
jacket overall, surface printed.

Standards
• TC Type Tray Cable per Article 340 of the NEC.
• Individual conductors pass UL Standard 44 and the VW-1 vertical flame test.
• Individual conductors approved as Type XHHW.
• Cables Pass IEEE-383 ribbon burner flame test.
• Overall jacket approved as Sunlight Resistant.
• Cables meet requirements of ICEA S-73-532, NEMA WC57 for control cables.
Notes
• Cables may be supplied with an insulated ground and marked “Open Wiring.”
• Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-
532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• Color Coding: ICEA Method 1, Table E-1
• EPR Insulation
• PVC, CPE, CSPE Jackets
• Insulated ground wires or bare ground wires
• Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 508
Copyright © 2018, American Wire Group, Inc. 20150508
Control Cable FR-XLPE Insulated Conductors
Smooth Helical Bare Copper Tape Shield,
Low Smoke Halogen Polyolefin XLPO Jacket, 600V

Item # Number of Conductor Conductor Copper Copper Nominal Nominal Nominal Nominal Approx. Approx.
Conductors Size Stranding Shield Shield Jacket Jacket Cable Cable Cable Cable
AWG Thickness Thickness Thickness Thickness O.D. O.D. Weight Weight
(in) (mm) (in) (mm) (in) (mm) /MFT /Km
(lb) (kg)
14-402SHX 2 14 7 .005 0.13 .045 1.1 0.445 11.3 109 162
14-403SHX 3 14 7 .005 0.13 .045 1.1 0.470 11.9 132 196
14-404SHX 4 14 7 .005 0.13 .045 1.1 0.505 12.8 155 231
14-405SHX 5 14 7 .005 0.13 .060 1.5 0.580 14.7 207 308
14-407SHX 7 14 7 .005 0.13 .060 1.5 0.620 15.7 246 366
14-409SHX 9 14 7 .005 0.13 .060 1.5 0.705 17.9 311 463
14-412SHX 12 14 7 .005 0.13 .060 1.5 0.785 19.9 393 585

12-452SHX 2 12 7 .005 0.13 .045 1.1 0.485 12.3 137 204


12-453SHX 3 12 7 .005 0.13 .045 1.1 0.510 13.0 163 243
12-454SHX 4 12 7 .005 0.13 .060 1.5 0.585 14.9 225 335
12-455SHX 5 12 7 .005 0.13 .060 1.5 0.630 16.0 259 385
12-457SHX 7 12 7 .005 0.13 .060 1.5 0.675 17.1 322 479
12-459SHX 9 12 7 .005 0.13 .060 1.5 0.775 19.7 409 609
12-462SHX 12 12 7 .005 0.13 .080 2.0 0.905 23.0 552 821

10-502SHX 2 10 7 .005 0.13 .045 1.1 0.535 13.6 179 266


10-503SHX 3 10 7 .005 0.13 .060 1.5 0.595 15.1 234 348
10-504SHX 4 10 7 .005 0.13 .060 1.5 0.640 16.3 289 430
10-505SHX 5 10 7 .005 0.13 .060 1.5 0.695 17.7 340 506
10-507SHX 7 10 7 .005 0.13 .060 1.5 0.750 19.1 442 658
10-509SHX 9 10 7 .005 0.13 .080 2.0 0.910 23.1 590 878
10-512SHX 12 10 7 .005 0.13 .080 2.0 1.010 25.7 748 1113
*Part numbers are for XLPO jacketed cables only.
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
508 Information on this sheet subject to change without notice.
20150508 Copyright © 2018, American Wire Group, Inc.
Control Cable FR-XLPE Insulated Conductors
Longitudinal Corrugated Bare Copper Tape Shield,
Low Smoke Halogen Polyolefin XLPO Jacket, 600V

Applications
Control or signal cable for important circuits in industrial plants and station control cable for electric
utilities where flame resistance is essential. Suitable for the operation and interconnection of pro-
tective devices; rated circuit voltage 600 volts; recommended for operation at 90°C maximum con-
tinuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts
or conduits, in tray or trough, and are suitable for direct burial.

Specifications
• Conductors conform to ASTM B-3 & B-8.
• Insulation conforms to UL Standard 44.
• TC Type Tray Cable per Article 340 of the NEC.
• Cables designed to pass the IEEE-383 & IEEE-1202 tests.
• Jacket suitable for Sunlight Resistant applications.
• Cables meet requirements of ICEA S-73-532 and ICEA S-95-658/NEMA WC70.
Construction
Stranded copper conductors, XLP insulated, Method 1 - Table E1 or E2 color coded or Method 4
phase-identified, conductors twisted with suitable fillers, Longitudinal Corrugated Bare Copper Tape
Shield, LSZH jacket overall, surface printed.

Options
Also available with -G Ground Wire, -SH Mylar Aluminum Foil Shield, No Shield

Notes
Dimensional data not binding, we reserve the right to alter specifications without notice. SHIPPING
TOLERANCE +/- 10%

Item # Cond. Number O.A. O.D. Weight


Size of (mil) (mil) /MFT
AWG or Conductors (lb)
or kcmil
18-02XLOHS 18 2 45 0.3 58
18-03XLOHS 18 3 45 0.3 75
18-04XLOHS 18 4 45 0.4 93
18-05XLOHS 18 5 45 0.4 114
18-07XLOHS 18 7 45 0.5 135
18-09XLOHS 18 9 45 0.5 172
18-12XLOHS 18 12 45 0.6 202
18-15XLOHS 18 15 60 0.6 229
18-19XLOHS 18 19 60 0.8 262

CONTROL CABLES
18-25XLOHS 18 25 60 0.9 323
18-31XLOHS 18 31 80 0.9 377
18-37XLOHS 18 37 80 1 448

16-02XLOHS 16 2 45 0.4 69
16-03XLOHS 16 3 45 0.4 84
16-04XLOHS 16 4 45 0.4 104
16-05XLOHS 16 5 60 0.4 119
16-07XLOHS 16 7 60 0.5 140
16-09XLOHS 16 9 60 0.6 181
16-12XLOHS 16 12 60 0.6 246
16-15XLOHS 16 15 80 0.7 302
16-19XLOHS 16 19 80 0.7 352
16-25XLOHS 16 25 80 0.8 469
16-31XLOHS 16 31 80 0.9 590
16-37XLOHS 16 37 80 1 675

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 531
Copyright © 2018, American Wire Group, Inc. 20150508
Control Cable FR-XLPE Insulated Conductors
Longitudinal Corrugated Bare Copper Tape Shield,
Low Smoke Halogen Polyolefin XLPO Jacket, 600V

Item # Cond. Number O.A. O.D. Weight


Size of (mil) (mil) /MFT
AWG or Conductors (lb)
or kcmil
14-02XLOHS 14 2 45 0.4 88
14-03XLOHS 14 3 45 0.4 109
14-04XLOHS 14 4 45 0.5 134
14-05XLOHS 14 5 45 0.5 155
14-07XLOHS 14 7 45 0.5 210
14-09XLOHS 14 9 60 0.7 296
14-12XLOHS 14 12 60 0.7 353
14-15XLOHS 14 15 60 0.8 450
14-19XLOHS 14 19 60 0.8 529
14-25XLOHS 14 25 80 1 740
14-31XLOHS 14 31 80 1.1 881
14-37XLOHS 14 37 80 1.2 1015

12-02XLOHS 12 2 45 0.5 119


12-03XLOHS 12 3 45 0.5 144
12-04XLOHS 12 4 45 0.5 180
12-05XLOHS 12 5 45 0.6 235
12-07XLOHS 12 7 60 0.6 295
12-09XLOHS 12 9 60 0.7 387
12-12XLOHS 12 12 60 0.8 498
12-15XLOHS 12 15 80 0.9 653
12-19XLOHS 12 19 80 1 759
12-25XLOHS 12 25 80 1.1 1021
12-31XLOHS 12 31 80 1.2 1217
12-37XLOHS 12 37 80 1.3 1413

10-02XLOHS 10 2 45 0.5 169


10-03XLOHS 10 3 45 0.5 205
10-04XLOHS 10 4 60 0.6 275
10-05XLOHS 10 5 60 0.7 331
10-07XLOHS 10 7 60 0.7 422
10-09XLOHS 10 9 60 0.8 537
CONTROL CABLES

10-12XLOHS 10 12 80 1 738
10-15XLOHS 10 15 80 1.1 904
10-19XLOHS 10 19 80 1.1 1080
10-25XLOHS 10 25 80 1.3 1431
10-31XLOHS 10 31 80 1.4 1724
10-37XLOHS 10 37 80 1.5 2005

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
531 Information on this sheet subject to change without notice.
20150508 Copyright © 2018, American Wire Group, Inc.
Control Cable
FR-EPR Insulated Conductors
PVC Jacket, 600V

Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in wet or dry
locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also ap-
proved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC
cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in
air, in ducts or conduits, in tray or trough, and are suitable for direct burial.

Construction
Stranded uncoated copper conductors, 30 mils Flame Retardant Ethylene Propylene Rubber (FR-
EPR) insulation, color coded, two conductors flat, three or more conductors twisted with suitable
fillers where necessary to make round, cable tape, PVC jacket overall, surface printed.

Standards
• Listed by UL as Type TC per Standard 1277 for Tray Cables.
• Cables UL listed for Direct Burial.
• Individual conductors pass UL VW-1 flame test.
• Individual conductors UL listed as Type XHHW-2.
• Overall jacket UL listed as Sunlight Resistant.
• Cables with grounding conductor UL listed for Open Wiring.
• Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test.
• Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
• Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables.
Notes
• Cables may be supplied with an insulated ground and marked “Open Wiring.”
• Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-
532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• Color Coding: ICEA Method 1, Table E-1
• FRXLP Insulation
• CPE, CSPE, LSOH Jackets
• Insulated ground wires or bare ground wires
• Overall copper tape shield
• Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 509
Copyright © 2018, American Wire Group, Inc. 20140110
Control Cable
FR-EPR Insulated Conductors
PVC Jacket, 600V

Item # Size Conductor Ground Nominal Nominal Nominal Nominal Nominal Nominal Copper Copper Approx. Approx.
AWG Strand Wire Insulation Insulation Jacket Jacket Cable Cable Weight Weight Weight Weight
Size Thickness Thickness Thickness Thickness O.D. O.D. /MFT /km /MFT /km
AWG (in) (mm) (in) (mm) (in) (mm) (lb) (kg) (lb) (kg)
14-E-PVC-2-FLAT 2 FLAT 14 7/.0242 0.030 0.76 0.045 1.14 .365x.230 9.30x5.80 26 38 61 91
14-E-PVC-3 3 14 7/.0242 0.030 0.76 0.045 1.14 0.390 9.910 39 59 92 137
14-E-PVC-4 4 14 7/.0242 0.030 0.76 0.045 1.14 0.425 10.800 53 78 115 171
14-E-PVC-5 5 14 7/.0242 0.030 0.76 0.045 1.14 0.465 11.810 66 98 139 207
14-E-PVC-7 7 14 7/.0242 0.030 0.76 0.045 1.14 0.505 12.830 92 137 173 257
14-E-PVC-9 9 14 7/.0242 0.030 0.76 0.060 1.52 0.620 15.750 118 176 240 357
14-E-PVC-12 12 14 7/.0242 0.030 0.76 0.060 1.52 0.700 17.780 158 235 301 448
14-E-PVC-19 19 14 7/.0242 0.030 0.76 0.060 1.52 0.815 20.700 250 372 468 696
14-E-PVC-25 25 14 7/.0242 0.030 0.76 0.080 2.03 0.935 23.750 323 481 624 929
14-E-PVC-30 30 14 7/.0242 0.030 0.76 0.080 2.03 1.030 26.160 387 576 747 1112
14-E-PVC-37 37 14 7/.0242 0.030 0.76 0.080 2.03 1.110 28.190 466 694 875 1302

12-E-PVC-2-FLAT 2 FLAT 12 7/.0305 0.030 0.76 0.045 1.14 .400x.245 10.20x6.20 42 63 82 122
12-E-PVC-2 2 12 7/.0305 0.030 0.76 0.045 1.14 0.410 10.410 42 63 94 140
12-E-PVC-3 3 12 7/.0305 0.030 0.76 0.045 1.14 0.435 11.050 64 95 124 185
12-E-PVC-4 4 12 7/.0305 0.030 0.76 0.045 1.14 0.475 12.070 85 127 157 234
12-E-PVC-5 5 12 7/.0305 0.030 0.76 0.045 1.14 0.520 13.210 106 158 191 284
12-E-PVC-7 7 12 7/.0305 0.030 0.76 0.060 1.52 0.595 15.110 149 221 268 399
12-E-PVC-9 9 12 7/.0305 0.030 0.76 0.060 1.52 0.695 17.650 191 285 337 502
12-E-PVC-12 12 12 7/.0305 0.030 0.76 0.060 1.52 0.765 19.430 247 368 428 637
12-E-PVC-19 19 12 7/.0305 0.030 0.76 0.080 2.03 0.940 23.880 391 582 688 1024
12-E-PVC-25 25 12 7/.0305 0.030 0.76 0.080 2.03 1.095 27.810 515 767 854 1271
12-E-PVC-30 30 12 7/.0305 0.030 0.76 0.080 2.03 1.150 29.210 618 920 1002 1491
12-E-PVC-37 37 12 7/.0305 0.030 0.76 0.080 2.03 1.240 31.500 762 1134 1240 1845

10-E-PVC-2-FLAT 2 FLAT 10 7/.0385 0.030 0.76 0.045 1.14 .445x.270 11.30x6.90 64 95 113 168
10-E-PVC-2 2 10 7/.0385 0.030 0.76 0.045 1.14 0.455 11.560 65 97 128 190
10-E-PVC-3 3 10 7/.0385 0.030 0.76 0.045 1.14 0.485 12.320 100 150 172 256
10-E-PVC-4 4 10 7/.0385 0.030 0.76 0.060 1.52 0.560 14.220 134 199 234 348
10-E-PVC-5 5 10 7/.0385 0.030 0.76 0.060 1.52 0.615 15.620 167 249 284 423
10-E-PVC-7 7 10 7/.0385 0.030 0.76 0.060 1.52 0.670 17.020 234 349 381 567
10-E-PVC-9 9 10 7/.0385 0.030 0.76 0.060 1.52 0.760 19.300 295 440 464 691
CONTROL CABLES

10-E-PVC-12 12 10 7/.0385 0.030 0.76 0.080 2.03 0.950 22.990 402 598 651 969

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
509 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Power Cable
EPR Insulated Conductors
PVC Jacket, 600V

Applications
As flame-retardant three or four conductor power cables rated 600V, 90°C. in wet or dry locations.
Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also
approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open
air, in ducts or conduits, in tray or trough, or direct buried.

Construction
Class B stranded tinned annealed copper conductor, Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II surface print phase identification. Color-coded per ICEA Method 4; individual con-
ductors colored black with conductor number surface printed in contrasting ink with a Class B
stranded uninsulated tinned annealed copper grounding conductor and PVC jacket overall, surface
printed.

Standards
• UL 44 Type XHHW-2
• UL 1277 Type TC-ER, UL File # E57179
• UL 1581
• ICEA S-95-658/NEMA WC70
• UL 1581 VW-1
• UL 1277
• IEEE 383
• IEEE 1202
• CSA FT4
• ICEA T-29-520
• Color Coding ICEA Method 4
Notes
• Ampacity in accordance with the National Electrical Code for cables in uncovered cable tray with-
out maintained spacing and for cables in raceway or directly buried; at the conductor temperature
indicated, in wet or dry locations, 30°C ambient temperature.
• Grounding conductor per UL Standard 1277 for Type TC Tray Cable.
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• E1 or E2 color codes
• FRXLP Insulation
• CPE, CSPE, LSOH Jackets
• Insulated ground wires or bare ground wires
• Overall copper tape shield
• Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

CONTROL CABLES
Consult AWG for a variety of alternate constructions for specific applications.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 510
Copyright © 2018, American Wire Group, Inc. 20140110
Power Cable
EPR Insulated Conductors
PVC Jacket, 600V

Item # Number of Size Conductor Ground Nominal Nominal Nominal Nominal Nominal Nominal Copper Copper Approx. Approx.
Conductors AWG Strand Wire Insulation Insulation Jacket Jacket Cable Cable Weight Weight Weight Weight
Size Thickness Thickness Thickness Thickness O.D. O.D. /MFT /km /MFT /Km
AWG (in) (mm) (in) (mm) (in) (mm) (lb) (kg) (lb) (kg)
3REPR-14 3 14 7/.0242 14 0.030 0.76 0.045 1.14 0.430 10.92 55 82 118 176
3REPR-12 3 12 7/.0305 12 0.030 0.76 0.045 1.14 0.480 12.19 87 129 160 238
3REPR-10 3 10 7/.0385 10 0.030 0.76 0.060 1.52 0.565 14.35 136 202 237 353

3REPR-8 3 8 7/.0486 10 0.045 1.14 0.060 1.52 0.655 16.64 190 283 314 467
4REPR-8 4 8 7/.0486 10 0.045 1.14 0.060 1.52 0.720 18.29 242 360 393 585

3REPR-6 3 6 7/.0612 8 0.045 1.14 0.00 1.52 0.740 18.80 297 442 456 679
4REPR-6 4 6 7/.0612 8 0.045 1.14 0.060 1.52 0.790 20.07 384 571 561 835

3REPR-4 3 4 7/.0772 8 0.045 1.14 0.080 2.03 0.880 22.35 442 658 642 955
4REPR-4 4 4 7/.0772 8 0.045 1.14 0.080 2.03 0.950 24.13 578 861 822 1223

3REPR-2 3 2 7/.0974 6 0.045 1.14 0.080 2.03 1.010 25.65 703 1046 979 1457
4REPR-2 4 2 7/.0974 6 0.045 1.14 0.080 2.03 1.090 27.69 919 1368 1235 1838

3REPR-1 3 1 19/.0664 6 0.055 1.40 0.080 2.03 1.120 28.45 872 1298 1021 1594
4REPR-1 4 1 19/.0664 6 0.055 1.40 0.080 2.03 1.235 31.37 1136 1691 1521 2264

3REPR-1/0 3 1/0 19/.0745 6 0.055 1.40 0.080 2.03 1.225 31.12 1069 1591 1439 2142
4REPR-1/0 4 1/0 19/.0745 6 0.055 1.40 0.080 2.03 1.330 33.78 1413 2103 1820 2709

3REPR-2/0 3 2/0 19/.0837 6 0.055 1.40 0.080 2.03 1.300 33.02 1340 1994 1720 2560
4REPR-2/0 4 2/0 19/.0837 6 0.055 1.40 0.080 2.03 1.440 36.58 1760 2619 2208 3286

3REPR-3/0 3 3/0 19/.0940 4 0.055 1.40 0.080 2.03 1.420 36.07 1717 2555 2176 3238
4REPR-3/0 4 3/0 19/.0940 4 0.055 1.40 0.080 2.03 1.570 39.88 2245 3341 2788 3405

3REPR-4/0 3 4/0 19/.1055 4 0.055 1.40 0.080 2.03 1.540 39.12 2130 3170 2614 3890
4REPR-4/0 4 4/0 19/.1055 4 0.055 1.40 0.110 2.79 1.790 45.47 2796 4161 3495 5201

3REPR-250 3 250 37/.0822 4 0.065 1.65 0.110 2.79 1.760 44.70 2494 3712 3184 4738
CONTROL CABLES

4REPR-250 4 250 37/.0822 4 0.065 1.65 0.110 2.79 1.915 48.64 3282 4884 4019 5981

3REPR-350 3 350 37/.0973 3 0.065 1.65 0.110 2.79 1.960 49.78 3474 5170 4187 6231
4REPR-350 4 350 37/.0973 3 0.065 1.65 0.110 2.79 2.165 54.99 4577 6811 5436 8090

3REPR-500 3 500 37/.1162 2 0.065 1.65 0.110 2.79 2.245 57.02 4934 7343 5847 8702
4REPR-500 4 500 37/.1162 2 0.065 1.65 0.110 2.79 2.475 62.87 6509 9687 7607 11321

3REPR-750 3 750 61/.1109 1 0.080 2.03 0.140 3.56 2.810 71.37 7278 10831 9145 13610
4REPR-750 4 750 61/.1109 1 0.080 2.03 0.140 3.56 3.115 79.12 9712 14453 11805 17569

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
510 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Control Cable
FR-EPR Insulated Conductors
CPE Jacket, 600V

Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in wet or dry
locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also ap-
proved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC
cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in
air, in ducts or conduits, in tray or trough, and are suitable for direct burial.

Construction
Stranded uncoated copper conductors, 30 mils Flame Retardant Ethylene Propylene Rubber (FR-
EPR) insulation, color coded, two conductors flat, three or more conductors twisted with suitable
fillers where necessary to make round, cable tape, CPE jacket overall, surface printed.

Standards
• Listed by UL as Type TC per Standard 1277 for Tray Cables.
• Cables UL listed for Direct Burial.
• Individual conductors pass UL VW-1 flame test.
• Individual conductors UL listed as Type XHHW-2.
• Overall jacket UL listed as Sunlight Resistant.
• Cables with grounding conductor UL listed for Open Wiring.
• Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test.
• Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
• Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables.
Notes
• Cables may be supplied with an insulated ground and marked “Open Wiring.”
• Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-
532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• Color Coding ICEAA Method 1, Table E-1
• FRXLP Insulation
• PVC, CSPE, LSOH Jackets
• Insulated ground wires or bare ground wires
• Overall copper tape shield
• Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 511
Copyright © 2018, American Wire Group, Inc. 20140110
Control Cable
FR-EPR Insulated Conductors
CPE Jacket, 600V

Item # Size Conductor Ground Nominal Nominal Nominal Nominal Nominal Nominal Copper Copper Approx. Approx.
AWG Strand Wire Insulation Insulation Jacket Jacket Cable Cable Weight Weight Weight Weight
Size Thickness Thickness Thickness Thickness O.D. O.D. /MFT /km /MFT /km
AWG (in) (mm) (in) (mm) (in) (mm) (lb) (kg) (lb) (kg)
14-E-CPE-2-FLAT 2 FLAT 14 7/.0242 0.030 0.76 0.045 1.14 .365x.230 9.30x5.80 26 38 61 91
14-E-CPE-3 3 14 7/.0242 0.030 0.76 0.045 1.14 0.390 9.910 39 59 92 137
14-E-CPE-4 4 14 7/.0242 0.030 0.76 0.045 1.14 0.425 10.800 53 78 115 171
14-E-CPE-5 5 14 7/.0242 0.030 0.76 0.045 1.14 0.465 11.810 66 98 139 207
14-E-CPE-7 7 14 7/.0242 0.030 0.76 0.045 1.14 0.505 12.830 92 137 173 257
14-E-CPE-9 9 14 7/.0242 0.030 0.76 0.060 1.52 0.620 15.750 118 176 240 357
14-E-CPE-12 12 14 7/.0242 0.030 0.76 0.060 1.52 0.700 17.780 158 235 301 448
14-E-CPE-19 19 14 7/.0242 0.030 0.76 0.060 1.52 0.815 20.700 250 372 468 696
14-E-CPE-25 25 14 7/.0242 0.030 0.76 0.080 2.03 0.935 23.750 323 481 624 929
14-E-CPE-30 30 14 7/.0242 0.030 0.76 0.080 2.03 1.030 26.160 387 576 747 1112
14-E-CPE-37 37 14 7/.0242 0.030 0.76 0.080 2.03 1.110 28.190 466 694 875 1302

12-E-CPE-2-FLAT 2 FLAT 12 7/.0305 0.030 0.76 0.045 1.14 .400x.245 10.20x6.20 42 63 82 122
12-E-CPE-2 2 12 7/.0305 0.030 0.76 0.045 1.14 0.410 10.410 42 63 94 140
12-E-CPE-3 3 12 7/.0305 0.030 0.76 0.045 1.14 0.435 11.050 64 95 124 185
12-E-CPE-4 4 12 7/.0305 0.030 0.76 0.045 1.14 0.475 12.070 85 127 157 234
12-E-CPE-5 5 12 7/.0305 0.030 0.76 0.045 1.14 0.520 13.210 106 158 191 284
12-E-CPE-7 7 12 7/.0305 0.030 0.76 0.060 1.52 0.595 15.110 149 221 268 399
12-E-CPE-9 9 12 7/.0305 0.030 0.76 0.060 1.52 0.695 17.650 191 285 337 502
12-E-CPE-12 12 12 7/.0305 0.030 0.76 0.060 1.52 0.765 19.430 247 368 428 637
12-E-CPE-19 19 12 7/.0305 0.030 0.76 0.080 2.03 0.940 23.880 391 582 688 1024
12-E-CPE-25 25 12 7/.0305 0.030 0.76 0.080 2.03 1.095 27.810 515 767 854 1271
12-E-CPE-30 30 12 7/.0305 0.030 0.76 0.080 2.03 1.150 29.210 618 920 1002 1491
12-E-CPE-37 37 12 7/.0305 0.030 0.76 0.080 2.03 1.240 31.500 762 1134 1240 1845

10-E-CPE-2-FLAT 2 FLAT 10 7/.0385 0.030 0.76 0.045 1.14 .445x.270 11.30x6.90 64 95 113 168
10-E-CPE-2 2 10 7/.0385 0.030 0.76 0.045 1.14 0.455 11.560 65 97 128 190
10-E-CPE-3 3 10 7/.0385 0.030 0.76 0.045 1.14 0.485 12.320 100 150 172 256
10-E-CPE-4 4 10 7/.0385 0.030 0.76 0.060 1.52 0.560 14.220 134 199 234 348
10-E-CPE-5 5 10 7/.0385 0.030 0.76 0.060 1.52 0.615 15.620 167 249 284 423
10-E-CPE-7 7 10 7/.0385 0.030 0.76 0.060 1.52 0.670 17.020 234 349 381 567
CONTROL CABLES

10-E-CPE-9 9 10 7/.0385 0.030 0.76 0.060 1.52 0.760 19.300 295 440 464 691
10-E-CPE-12 12 10 7/.0385 0.030 0.76 0.080 2.03 0.950 22.990 402 598 651 969

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
511 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Power Cable
EPR Insulated Conductors
CPE Jacket, 600V

Applications
As flame-retardant three or four conductor power cables rated 600V, 90°C in wet or dry locations.
Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also
approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open
air, in ducts or conduits, in tray or trough, or direct buried.

Construction
Class B stranded tinned annealed copper conductor, Flame-Retardant Ethylene Propylene Rubber
(FR-EPR) Type II surface print phase identification. Color-coded per ICEA Method 4; individual con-
ductors colored black with conductor number surface printed in contrasting ink with a Class B
stranded uninsulated tinned annealed copper grounding conductor and CPE jacket overall, surface
printed.

Standards
• UL 44 Type XHHW-2
• UL 1277 Type TC-ER, UL File # E57179
• UL 1581
• ICEA S-95-658/NEMA WC70
• UL 1581 VW-1
• UL 1277
• IEEE 383
• IEEE 1202
• CSA FT4
• ICEA T-29-520
• Color Code ICEA Method 4
Notes
• Ampacity in accordance with the National Electrical Code for cables in uncovered cable tray with-
out maintained spacing and for cables in raceway or directly buried; at the conductor temperature
indicated, in wet or dry locations, 30°C ambient temperature.
• Grounding conductor per UL Standard 1277 for Type TC Tray Cable.
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• E1 or E2 color codes
• FRXLP Insulation
• PVC, CSPE, LSOH Jackets
• Insulated ground wires or bare ground wires
• Overall copper tape shield
• Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

CONTROL CABLES
Consult AWG for a variety of alternate constructions for specific applications.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 512
Copyright © 2018, American Wire Group, Inc. 20140110
Power Cable
EPR Insulated Conductors
CPE Jacket, 600V

Item # Number of Size Conductor Ground Nominal Nominal Nominal Nominal Nominal Nominal Copper Copper Approx. Approx.
Conductors AWG Strand Wire Insulation Insulation Jacket Jacket Cable Cable Weight Weight Weight Weight
Size Thickness Thickness Thickness Thickness O.D. O.D. /MFT /km /MFT /Km
AWG (in) (mm) (in) (mm) (in) (mm) (lb) (kg) (lb) (kg)
3EEPR-14 3 14 7/.0242 14 0.0300 0.76 0.045 1.14 0.430 10.92 55 82 118 176
3EEPR-12 3 12 7/.0305 12 0.0300 0.76 0.045 1.14 0.480 12.19 87 129 160 238
3EEPR-10 3 10 7/.0385 10 0.0300 0.76 0.060 1.52 0.565 14.35 136 202 237 353

3EEPR-8 3 8 7/.0486 10 0.045 1.14 0.060 1.52 0.655 16.64 190 283 314 467
4EEPR-8 4 8 7/.0486 10 0.045 1.14 0.060 1.52 0.720 18.29 242 360 393 585

3EEPR-6 3 6 7/.0612 8 0.045 1.14 0.060 1.52 0.740 18.80 297 442 456 679
4EEPR-6 4 6 7/.0612 8 0.045 1.14 0.060 1.52 0.790 20.07 384 571 561 835

3EEPR-4 3 4 7/.0772 8 0.045 1.14 0.080 2.03 0.880 22.35 442 658 642 955
4EEPR-4 4 4 7/.0772 8 0.045 1.14 0.080 2.03 0.950 24.13 578 861 822 1223

3EEPR-2 3 2 7/.0974 6 0.045 1.14 0.080 2.03 1.010 25.65 703 1046 979 1457
4EEPR-2 4 2 7/.0974 6 0.045 1.14 0.080 2.03 1.090 27.69 919 1368 1235 1838

3EEPR-1 3 1 19/.0664 6 0.055 1.40 0.080 2.03 1.120 28.45 872 1298 1021 1594
4EEPR-1 4 1 19/.0664 6 0.055 1.40 0.080 2.03 1.235 31.37 1136 1691 1521 2264

3EEPR-1/0 3 1/0 19/.0745 6 0.055 1.40 0.080 2.03 1.225 31.12 1069 1591 1439 2142
4EEPR-1/0 4 1/0 19/.0745 6 0.055 1.40 0.080 2.03 1.330 33.78 1413 2103 1820 2709

3EEPR-2/0 3 2/0 19/.0837 6 0.055 1.40 0.080 2.03 1.300 33.02 1340 1994 1720 2560
4EEPR-2/0 4 2/0 19/.0837 6 0.055 1.40 0.080 2.03 1.440 36.58 1760 2619 2208 3286

3EEPR-3/0 3 3/0 19/.0940 4 0.055 1.40 0.080 2.03 1.420 36.07 1717 2555 2176 3238
4EEPR-3/0 4 3/0 19/.0940 4 0.055 1.40 0.080 2.03 1.570 39.88 2245 3341 2788 3405

3EEPR-4/0 3 4/0 19/.1055 4 0.055 1.40 0.080 2.03 1.540 39.12 2130 3170 2614 3890
4EEPR-4/0 4 4/0 19/.1055 4 0.055 1.40 0.110 2.79 1.790 45.47 2796 4161 3495 5201

3EEPR-250 3 250 37/.0822 4 0.065 1.65 0.110 2.79 1.760 44.70 2494 3712 3184 4738
CONTROL CABLES

4EEPR-250 4 250 37/.0822 4 0.065 1.65 0.110 2.79 1.915 48.64 3282 4884 4019 5981

3EEPR-350 3 350 37/.0973 3 0.065 1.65 0.110 2.79 1.960 49.78 3474 5170 4187 6231
4EEPR-350 4 350 37/.0973 3 0.065 1.65 0.110 2.79 2.165 54.99 4577 6811 5436 8090

3EEPR-500 3 500 37/.1162 2 0.065 1.65 0.110 2.79 2.245 57.02 4934 7343 5847 8702
4EEPR-500 4 500 37/.1162 2 0.065 1.65 0.110 2.79 2.475 62.87 6509 9687 7607 11321

3EEPR-750 3 750 61/.1109 1 0.080 2.03 0.140 3.56 2.810 71.37 7278 10831 9145 13610
4EEPR-750 4 750 61/.1109 1 0.080 2.03 0.140 3.56 3.115 79.12 9712 14453 11805 17569

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
512 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Control Cable
FR-EPR Insulated Conductors
Copper Shield, CPE Jacket, 600V

Applications
Control or signal cable for important circuits in industrial plants and station control cable for electric
utilities where flame resistance is essential. Suitable for the operation and interconnection of pro-
tective devices; rated circuit voltage 600V; recommended for operation at 90°C maximum continu-
ous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or
conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL
requirements.

Construction
Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene
rubber (EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1 color-
coded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket over-
all, surface printed.

Standards
• TC Type Tray Cable per Article 340 of the NEC.
• Individual conductors pass UL Standard 44 and the VW-1 vertical flame test.
• Individual conductors approved as Type XHHW.
• Cables Pass IEEE-383 ribbon burner flame test.
• Overall jacket approved as Sunlight Resistant.
• Cables meet requirements of ICEA S-73-532/NEMA WC57 for control cables.
Notes
• Cables may be supplied with an insulated ground and marked “Open Wiring.”
• Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-
532(TECH I006). This color coding method omits white and green from the color sequence. A
white or green conductor can be supplied on request.
Options
• Bare or Tinned Copper
• Flexible stranded conductors
• Color Coding: ICEA Method 1, Table E-1
• FRXLP Insulation
• PVC, CSPE, LSOH Jackets
• Insulated ground wires or bare ground wires
• Overall copper braid shield
• Overall longitudinal corrugated copper shield
• Overall mylar tape shield with drain wire
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 513
Copyright © 2018, American Wire Group, Inc. 20140110
Control Cable
FR-EPR Insulated Conductors
Copper Shield, CPE Jacket, 600V

Item # Number of Conductor Conductor Copper Copper Nominal Nominal Nominal Nominal Approx. Approx.
Conductors Size Stranding Shield Shield Jacket Jacket Cable Cable Cable Cable
AWG Thickness Thickness Thickness Thickness O.D. O.D. Weight Weight
(in) (mm) (in) (mm) (in) (mm) /MFT /Km
(lb) (kg)
14-402ESH 2 14 7 .005 0.13 .045 1.1 0.445 11.3 109 162
14-403ESH 3 14 7 .005 0.13 .045 1.1 0.470 11.9 132 196
14-404ESH 4 14 7 .005 0.13 .045 1.1 0.505 12.8 155 231
14-405ESH 5 14 7 .005 0.13 .060 1.5 0.580 14.7 207 308
14-407ESH 7 14 7 .005 0.13 .060 1.5 0.620 15.7 246 366
14-409ESH 9 14 7 .005 0.13 .060 1.5 0.705 17.9 311 463
14-412ESH 12 14 7 .005 0.13 .060 1.5 0.785 19.9 393 585

12-452ESH 2 12 7 .005 0.13 .045 1.1 0.485 12.3 137 204


12-453ESH 3 12 7 .005 0.13 .045 1.1 0.510 13.0 163 243
12-454ESH 4 12 7 .005 0.13 .060 1.5 0.585 14.9 225 335
12-455ESH 5 12 7 .005 0.13 .060 1.5 0.630 16.0 259 385
12-457ESH 7 12 7 .005 0.13 .060 1.5 0.675 17.1 322 479
12-459ESH 9 12 7 .005 0.13 .060 1.5 0.775 19.7 409 609
12-462ESH 12 12 7 .005 0.13 .080 2.0 0.905 23.0 552 821

10-502ESH 2 10 7 .005 0.13 .045 1.1 0.535 13.6 179 266


10-503ESH 3 10 7 .005 0.13 .060 1.5 0.595 15.1 234 348
10-504ESH 4 10 7 .005 0.13 .060 1.5 0.640 16.3 289 430
10-505ESH 5 10 7 .005 0.13 .060 1.5 0.695 17.7 340 506
10-507ESH 7 10 7 .005 0.13 .060 1.5 0.750 19.1 442 658
10-509ESH 9 10 7 .005 0.13 .080 2.0 0.910 23.1 590 878
10-512ESH 12 10 7 .005 0.13 .080 2.0 1.010 25.7 748 1113

08-552ESH 2 8 7 .005 0.13 .060 1.5 0.695 17.7 288 429


08-553ESH 3 8 7 .005 0.13 .060 1.5 0.735 18.7 365 543
08-554ESH 4 8 7 .005 0.13 .060 1.5 0.795 20.2 444 661

06-602ESH 2 6 7 .005 0.13 .060 1.5 0.775 19.7 378 562


06-603ESH 3 6 7 .005 0.13 .060 1.5 0.820 20.8 494 735
06-603ESH 4 6 7 .005 0.13 .080 2.0 0.935 23.4 645 956
CONTROL CABLES

04-502ESH 2 4 7 .005 0.13 .080 2.0 0.915 23.2 550 818


04-503ESH 3 4 7 .005 0.13 .080 2.0 0.965 24.5 722 1074
04-554ESH 4 4 7 .005 0.13 .080 2.0 1.055 26.8 903 1344

02-503ESH 2 2 7 .005 0.13 .080 2.0 1.035 26.3 758 1128


02-554ESH 3 2 7 .005 0.13 .080 2.0 1.100 27.9 1007 1498
02-554ESH 4 2 7 .005 0.13 .080 2.0 1.200 30.5 1288 1917

01-503ESH 2 1 19 .005 0.13 .080 2.0 1.230 31.2 1236 1839


01-554ESH 3 1 19 .005 0.13 .080 2.0 1.350 34.3 1564 2327

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
513 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
20/10 Control Cable
PE/PVC Insulated Conductors
PVC Jacket, 600V

Applications
Standard general purpose control cable for important control circuits in industrial plants and station
control cable for utilities. Suitable for operation and interconnection of protective devices; rated cir-
cuit voltage 600V, recommended for operation at 75°C maximum continuous conductor tempera-
ture. For Non NEC Application Cables may be installed in open air, in ducts or conduit, or in tray or
trough and direct burial. For metering installations where insulated conductors are subject to sun-
light degradation, these cables can be jacketed with special UV-resistant compounds.

Construction
Stranded uncoated copper conductors, 20 mils black high molecular weight polyethylene insulation,
10 mils full color coded PVC Jacket over each insulated conductor, two conductors flat, three or
more conductors twisted with suitable fillers where necessary to make round, polyester tape over
assembly, PVC jacket overall, surface printed.

Standards
Physical and electrical tests in accordance with appropriate sections of ICEA S-73-532, NEMA WC57.

Notes
• Single conductor 20 mils high molecular weight polyethylene insulation and 10 mils polyvinyl
chloride jacket, 600V.
• Color coding is ICEA Appendix E Method 1 Table E-1.
Options
• Flexible stranded conductors
• Tin-coated copper conductors per ASTM B33
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications.

Item # Number of Conductor Conductor Nominal Nominal Nominal Nominal Approximate Approximate
Conductors Size Stranding Jacket Jacket Cable Cable Cable Weight Cable Weight
AWG Thickness Thickness O.D. O.D. /MFT /Km
(in) (mm) (in) (mm) (lb) (kg)
14-CTB-2 2 14 7 .045 1.1 .235 x .375 5.97 x 9.53 63 93
14-CTB-3 3 14 7 .045 1.1 0.400 10.2 95 141
14-CTB-4 4 14 7 .045 1.1 0.435 11.0 117 173
14-CTB-5 5 14 7 .045 1.1 0.475 12.1 132 195
14-CTB-7 7 14 7 .045 1.1 0.515 13.1 174 258
14-CTB-9 9 14 7 .060 1.5 0.640 16.3 238 352
14-CTB-12 12 14 7 .060 1.5 0.710 18.0 305 451

CONTROL CABLES
14-CTB-15 15 14 7 .060 1.5 0.785 19.9 370 548
14-CTB-19 19 14 7 .060 1.5 0.825 21.0 453 670
14-CTB-25 25 14 7 .080 2.0 1.030 26.2 624 924
14-CTB-30 30 14 7 .080 2.0 1.065 27.1 693 1026
14-CTB-37 37 14 7 .080 2.0 1.150 29.2 832 1231

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 514
Copyright © 2018, American Wire Group, Inc. 20140110
20/10 Control Cable
PE/PVC Insulated Conductors
PVC Jacket, 600V

Item # Number of Conductor Conductor Nominal Nominal Nominal Nominal Approximate Approximate
Conductors Size Stranding Jacket Jacket Cable Cable Cable Weight Cable Weight
AWG Thickness Thickness O.D. O.D. /MFT /Km
(in) (mm) (in) (mm) (lb) (kg)
12-CTB-2 2 12 7 .045 1.1 .255 x .415 6.48 x 10.50 85 126
12-CTB-3 3 12 7 .045 1.1 0.445 11.3 126 186
12-CTB-4 4 12 7 .045 1.1 0.485 12.3 158 234
12-CTB-5 5 12 7 .045 1.1 0.560 14.2 200 296
12-CTB-7 7 12 7 .060 1.5 0.610 15.5 259 383
12-CTB-9 9 12 7 .060 1.5 0.715 18.2 328 485
12-CTB-12 12 12 7 .060 1.5 0.795 20.2 423 626
12-CTB-15 15 12 7 .080 2.0 0.920 23.4 554 820
12-CTB-19 19 12 7 .080 2.0 0.970 24.6 675 999
12-CTB-25 25 12 7 .080 2.0 1.150 29.2 865 1280
12-CTB-30 30 12 7 .080 2.0 1.195 30.4 1020 1510
12-CTB-37 37 12 7 .080 2.0 1.290 32.8 1234 1826

10-CTB-2 2 10 7 .045 1.1 .280 x .460 7.11 x 11.7 116 171


10-CTB-3 3 10 7 .045 1.1 0.495 12.6 170 252
10-CTB-4 4 10 7 .060 1.5 0.580 14.7 235 348
10-CTB-5 5 10 7 .060 1.5 0.625 15.9 274 406
10-CTB-7 7 10 7 .060 1.5 0.680 17.3 364 539
10-CTB-9 9 10 7 .060 1.5 0.805 20.4 462 684
10-CTB-12 12 10 7 .080 2.0 0.935 23.7 638 944
10-CTB-15 15 10 7 .080 2.0 1.035 26.3 780 1154
10-CTB-19 19 10 7 .080 2.0 1.090 27.7 958 1418
10-CTB-25 25 10 7 .080 2.0 1.300 33.0 1245 1843
10-CTB-30 30 10 7 .080 2.0 1.350 34.3 1464 2167
10-CTB-37 37 10 7 .080 2.0 1.460 37.1 1778 2631

9-CTB-2 2 9 7 .045 1.1 .290 x .490 7.37 x 12.4 132 195


9-CTB-3 3 9 7 .045 1.1 0.520 13.2 188 278
9-CTB-4 4 9 7 .060 1.5 0.600 15.2 258 382
9-CTB-5 5 9 7 .060 1.5 0.660 16.8 313 463
9-CTB-7 7 9 7 .060 1.5 0.720 18.3 418 619
9-CTB-9 9 9 7 .060 1.5 0.845 21.5 530 784
CONTROL CABLES

9-CTB-12 12 9 7 .080 2.0 0.985 25.0 731 1082


9-CTB-15 15 9 7 .080 2.0 1.095 27.8 896 1326
9-CTB-19 19 9 7 .080 2.0 1.150 29.2 1100 1628
9-CTB-25 25 9 7 .080 2.0 1.380 35.1 1433 2121
9-CTB-30 30 9 7 .080 2.0 1.430 36.3 1688 2499
9-CTB-37 37 9 7 .080 2.0 1.545 39.2 2050 3034

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
514 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
20/10 Control Cable
PE/PVC Insulated Conductors
Shielded, PVC Jacket, 600V

Applications
Standard general purpose control cable for important control circuits in industrial plants and station
control cable for utilities. Suitable for operation and interconnection of protective devices; rated cir-
cuit voltage 600V, recommended for operation at 75°C maximum continuous conductor tempera-
ture. For Non NEC Application Cables may be installed in open air, in ducts or conduit, or in tray or
trough and direct burial. For metering installations where insulated conductors are exposed to sun-
light degradations, these cables can be jacketed with special UV-resistant compounds.

Construction
Stranded uncoated copper conductors, 20 mils black high molecular weight polyethylene insulation,
10 mils full color coded PVC Jacket over each insulated conductor, two conductors flat, three or
more conductors twisted with suitable fillers where necessary to make round, polyester tape over
assembly, copper tape shield, PVC jacket overall, surface printed.

Standards
Physical and electrical tests in accordance with appropriate sections of ICEA S-73-532, NEMA WC57.

Notes
• Single conductor 20 mils high molecular weight polyethylene insulation and 10 mils polyvinyl
chloride jacket, 600V.
• Color coding is ICEA Appendix E Method 1 Table E-1.
Options
• Flexible stranded conductors
• Tin-coated copper conductors per ASTM B33
• Copper braid shield
• 1000V rated construction

Consult AWG for a variety of alternate constructions for specific applications.

Item # Number of Conductor Conductor Copper Copper Nominal Nominal Nominal Nominal Approx. Approx.
Conductors Size Stranding Shield Shield Jacket Jacket Cable Cable Cable Cable
AWG Thickness Thickness Thickness Thickness O.D. O.D. Weight Weight
(in) (mm) (in) (mm) (in) (mm) /MFT /Km
(lb) (kg)
10-CTB-2-S 2 10 7 .005 0.1 .060 1.5 0.600 15.2 233 345
10-CTB-3-S 3 10 7 .005 0.1 .060 1.5 0.640 16.3 285 423
10-CTB-4-S 4 10 7 .005 0.1 .060 1.5 0.695 17.7 333 493

9-CTB-3-S 3 9 7 .005 0.1 .060 1.5 0.620 15.7 258 382

CONTROL CABLES
9-CTB-4-S 4 9 7 .005 0.1 .060 1.5 0.670 17.0 318 471
9-CTB-5-S 5 9 7 .005 0.1 .060 1.5 0.725 18.4 377 558

8-CTB-3-S 3 8 7 .005 0.1 .060 1.5 0.805 20.4 391 579


8-CTB-4-S 4 8 7 .005 0.1 .080 2.0 0.920 23.4 511 756

6-CTB-3-S 3 6 7 .005 0.1 .080 2.0 0.980 24.9 585 866


6-CTB-4-S 4 6 7 .005 0.1 .080 2.0 1.065 27.1 722 1069

4-CTB-3-S 3 4 7 .005 0.1 .080 2.0 1.090 27.7 771 1141


4-CTB-4-S 4 4 7 .005 0.1 .080 2.0 1.190 30.2 982 1453

2-CTB-3-S 3 2 7 .005 0.1 .080 2.0 1.225 31.1 1076 1592


2-CTB-4-S 4 2 7 .005 0.1 .080 2.0 1.345 34.2 1369 2026

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 515
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
TFN, THWN or THHN Insulated Conductors
PVC Jacket, 600V

Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in dry loca-
tions, 75°C in wet locations. Specifically approved for installation in cable trays per Article 336 of the
NEC. Also approved for use in Class 1 remote-control and signaling circuits per Article 725 of the
NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may
be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial.

Construction
Individual conductors of stranded uncoated copper Type TFN (16AWG). Type THWN or THHN (14-10
AWG), color-coded, two conductors flat, three or more conductors twisted, PVC jacket overall, sur-
face printed.

Standards
• Listed by UL as Type TC Tray Cable per Article 336 of the NEC.
• Individual conductors UL listed as Type THWN or THHN (14-10 AWG) or Type TFN (16 AWG).
• Overall jacket UL listed as Sunlight Resistant.
• Cables UL listed for Direct Burial.
• Cables with grounding conductor UL listed for Open Wiring.
• Cables pass UL and IEEE-383 ribbon burner tests and ICEA 210.00 BTU/hr test.
Notes
• Cables designated (w/g) contain an additional bare copper grounding conductor, same size as cir-
cuit conductors, and are UL listed for Open Wiring.
• Standard color-coding is ICEA Method E2 or K2 for NEC applications. This color-coding method
omits white and green from the color sequence.
• ICEA Method 4 color-coding is also provided. This consists of printed numbers and words, 1-ONE,
2-TWO, etc.
• Size 16 AWG is rated 90°C dry only.

Item # Number of Size Number of Overall Nominal Weight


Conductors AWG Strands PVC Jacket Diameter /MFT
(mil) (in) (lb)
16-TC1-2 2 16 7 45 .20 x .30 40
16-TC1-3 3 16 7 45 0.32 60
16-TC1-3 w/g 3 w/g 16 7 N/A N/A N/A
16-TC1-4 4 16 7 45 0.34 75
16-TC1-5 5 16 7 45 0.37 85
16-TC1-6 6 16 7 45 0.40 100
16-TC1-7 7 16 7 45 0.40 110
16-TC1-8 8 16 7 45 0.44 130

CONTROL CABLES
16-TC1-9 9 16 7 45 0.47 140
16-TC1-10 10 16 7 45 0.51 155
16-TC1-11 11 16 7 45 0.51 170
16-TC1-12 12 16 7 60 0.55 200
16-TC1-13 13 16 7 60 0.56 210
16-TC1-14 14 16 7 60 0.58 225
16-TC1-15 15 16 7 60 0.61 240
16-TC1-16 16 16 7 60 0.61 250
16-TC1-17 17 16 7 60 0.64 265
16-TC1-18 18 16 7 60 0.64 275
16-TC1-19 19 16 7 60 0.64 285
16-TC1-20 20 16 7 60 0.67 305
16-TC1-23 23 16 7 60 0.70 340
16-TC1-25 25 16 7 60 0.74 370

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 517
Copyright © 2018, American Wire Group, Inc. 20140902
TFN, THWN or THHN Insulated Conductors
PVC Jacket, 600V

Item # Number of Size Number of Overall Nominal Weight


Conductors AWG Strands PVC Jacket Diameter /MFT
(mil) (in) (lb)
16-TC1-27 27 16 7 60 0.76 395
16-TC1-29 29 16 7 60 0.77 420
16-TC1-31 31 16 7 60 0.80 445
16-TC1-32 32 16 7 60 0.82 460
16-TC1-37 37 16 7 80 0.89 550

14-TC1-2 2 14 7 45 .21 x .33 55


14-TC1-3 3 14 7 45 0.34 75
14-TC1-3 w/g 3 w/g 14 7 45 0.35 92
14-TC1-4 4 14 7 45 0.37 100
14-TC1-5 5 14 7 45 0.41 115
14-TC1-6 6 14 7 45 0.44 140
14-TC1-7 7 14 7 45 0.44 150
14-TC1-8 8 14 7 45 0.48 170
14-TC1-9 9 14 7 45 0.51 195
14-TC1-10 10 14 7 60 0.58 220
14-TC1-11 11 14 7 60 0.58 240
14-TC1-12 12 14 7 60 0.60 265
14-TC1-13 13 14 7 60 0.62 280
14-TC1-14 14 14 7 60 0.64 295
14-TC1-15 15 14 7 60 0.66 310
14-TC1-16 16 14 7 60 0.66 340
14-TC1-17 17 14 7 60 0.70 355
14-TC1-18 18 14 7 60 0.70 370
14-TC1-19 19 14 7 60 0.70 390
14-TC1-20 20 14 7 60 0.73 415
14-TC1-23 23 14 7 60 0.78 475
14-TC1-25 25 14 7 80 0.85 540
14-TC1-27 27 14 7 80 0.88 570
14-TC1-29 29 14 7 80 0.90 600
14-TC1-31 31 14 7 80 0.92 640
14-TC1-32 32 14 7 80 0.94 660
CONTROL CABLES

14-TC1-37 37 14 7 80 0.96 755

12-TC1-2 2 12 7 45 .23 x .37 75


12-TC1-3 3 12 7 45 0.36 105
12-TC1-3 w/g 3 w/g 12 7 45 0.40 130
12-TC1-4 4 12 7 45 0.40 135
12-TC1-5 5 12 7 45 0.45 165
12-TC1-6 6 12 7 45 0.50 195
12-TC1-7 7 12 7 45 0.50 215
12-TC1-8 8 12 7 60 0.58 260
12-TC1-9 9 12 7 60 0.62 300
12-TC1-10 10 12 7 60 0.66 325
12-TC1-11 11 12 7 60 0.66 350
12-TC1-12 12 12 7 60 0.68 375

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
517 Information on this sheet subject to change without notice.
20140902 Copyright © 2018, American Wire Group, Inc.
TFN, THWN or THHN Insulated Conductors
PVC Jacket, 600V

Item # Number of Size Number of Overall Nominal Weight


Conductors AWG Strands PVC Jacket Diameter /MFT
(mil) (in) (lb)
12-TC1-13 13 12 7 60 0.70 400
12-TC1-14 14 12 7 60 0.73 425
12-TC1-15 15 12 7 60 0.76 455
12-TC1-16 16 12 7 60 0.76 485
12-TC1-17 17 12 7 60 0.79 515
12-TC1-18 18 12 7 60 0.79 545
12-TC1-19 19 12 7 60 0.79 656
12-TC1-20 20 12 7 80 0.89 590
12-TC1-23 23 12 7 80 0.93 690
12-TC1-25 25 12 7 80 0.96 770
12-TC1-27 27 12 7 80 1.00 840
12-TC1-29 29 12 7 80 1.01 910
12-TC1-31 31 12 7 80 1.06 950
12-TC1-32 32 12 7 80 1.08 1000
12-TC1-37 37 12 7 80 1.10 1090

10-TC1-2 2 10 7 45 .26 x .43 110


10-TC1-3 3 10 7 45 0.46 155
10-TC1-3 w/g 3 w/g 10 7 45 0.47 194
10-TC1-4 4 10 7 45 0.50 200
10-TC1-5 5 10 7 60 0.58 265
10-TC1-6 6 10 7 60 0.63 315
10-TC1-7 7 10 7 60 0.63 345
10-TC1-8 8 10 7 60 0.69 420
10-TC1-9 9 10 7 60 0.73 450
10-TC1-10 10 10 7 60 0.81 500
10-TC1-11 11 10 7 60 0.81 540
10-TC1-12 12 10 7 60 0.82 580
10-TC1-13 13 10 7 80 0.89 680
10-TC1-14 14 10 7 80 0.92 725
10-TC1-15 15 10 7 80 0.95 745
10-TC1-16 16 10 7 80 0.95 810

CONTROL CABLES
10-TC1-17 17 10 7 80 1.02 860
10-TC1-18 18 10 7 80 1.02 900
10-TC1-19 19 10 7 80 1.02 940
10-TC1-20 20 10 7 80 1.07 990
10-TC1-23 23 10 7 80 1.12 1120
10-TC1-25 25 10 7 80 1.19 1210
10-TC1-27 27 10 7 80 1.22 1295
10-TC1-29 29 10 7 80 1.23 1375
10-TC1-31 31 10 7 80 1.29 1465
10-TC1-32 32 10 7 80 1.31 1510
10-TC1-37 37 10 7 80 1.36 1710

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 517
Copyright © 2018, American Wire Group, Inc. 20140902
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
TFN, THWN or THHN Insulated Conductors
Overall Shield, Drain Wire, 600V

Applications
As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in dry loca-
tions. 75°C in wet locations. Specifically approved for installation in cable trays per Article 336 of the
NEC. Also approved for use in Class 1 remote-control and signaling circuits per Article 725 of the
NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may
be installed in air, in ducts or conduits, in tray or trough, are suitable for direct burial.

Construction
Individual conductors of stranded uncoated copper Type TFN (16AWG). Type THWN or THHN (14-10
AWG), color-coded, cabled singles, overall aluminum/polyester foil tape plus tinned Cu drain wire,
PVC jacket, surface printed.

Standards
• Listed by UL as Type TC Tray Cable per Article 336 of the NEC.
• Individual conductors UL listed as Type THWN or THHN (14-10 AWG) or Type TFN (16 AWG).
• Overall jacket UL listed as Sunlight Resistant.
• Cables UL listed for Direct Burial.
• Cables pass UL and IEEE-383 ribbon burner tests and ICEA 210.00 BTU/hr test.
Notes
• Drain wire 18 AWG on size 16 AWG conductor constructions, and 16 AWG on all other sizes.
• Class 1 circuits as defined in Article 725.
• Class 1, Division II Hazardous Locations per Article 501.4(B).
• Aerial use permitted with a messenger.
• Standard Color Coding also available ICEA Method 1, Table E-1

Item # Number of Size Number of Overall Nominal Weight


Conductors AWG Strands PVC Jacket Diameter /MFT
(mil) (in) (lb)
16-TCCU-2 2 16 7 45 0.32 54
16-TCCU-3 3 16 7 45 0.32 60
16-TCCU-4 4 16 7 45 0.34 75
16-TCCU-5 5 16 7 45 0.37 85
16-TCCU-6 6 16 7 45 0.40 100
16-TCCU-7 7 16 7 45 0.40 110
16-TCCU-8 8 16 7 45 0.44 130
16-TCCU-9 9 16 7 45 0.47 140
16-TCCU-10 10 16 7 45 0.51 155
16-TCCU-11 11 16 7 45 0.51 170
16-TCCU-12 12 16 7 60 0.55 200

CONTROL CABLES
16-TCCU-13 13 16 7 60 0.56 210
16-TCCU-14 14 16 7 60 0.58 225
16-TCCU-15 15 16 7 60 0.61 240
16-TCCU-16 16 16 7 60 0.61 250
16-TCCU-17 17 16 7 60 0.64 265
16-TCCU-18 18 16 7 60 0.64 275
16-TCCU-19 19 16 7 60 0.64 285
16-TCCU-20 20 16 7 60 0.67 305
16-TCCU-23 23 16 7 60 0.70 340
16-TCCU-25 25 16 7 60 0.74 370
16-TCCU-27 27 16 7 60 0.76 395
16-TCCU-29 29 16 7 60 0.77 420
16-TCCU-31 31 16 7 60 0.80 445
16-TCCU-32 32 16 7 60 0.82 460
16-TCCU-37 37 16 7 80 0.89 550

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 518
Copyright © 2018, American Wire Group, Inc. 20140902
TFN, THWN or THHN Insulated Conductors
Overall Shield, Drain Wire, 600V

Item # Number of Size Number of Overall Nominal Weight


Conductors AWG Strands PVC Jacket Diameter /MFT
(mil) (in) (lb)
14-TCCU-2 2 14 7 45 0.34 71
14-TCCU-3 3 14 7 45 0.34 75
14-TCCU-4 4 14 7 45 0.37 100
14-TCCU-5 5 14 7 45 0.41 115
14-TCCU-6 6 14 7 45 0.44 140
14-TCCU-7 7 14 7 45 0.44 150
14-TCCU-8 8 14 7 45 0.48 170
14-TCCU-9 9 14 7 45 0.51 195
14-TCCU-10 10 14 7 60 0.58 220
14-TCCU-11 11 14 7 60 0.58 240
14-TCCU-12 12 14 7 60 0.60 265
14-TCCU-13 13 14 7 60 0.62 280
14-TCCU-14 14 14 7 60 0.64 295
14-TCCU-15 15 14 7 60 0.66 310
14-TCCU-16 16 14 7 60 0.66 340
14-TCCU-17 17 14 7 60 0.70 355
14-TCCU-18 18 14 7 60 0.70 370
14-TCCU-19 19 14 7 60 0.70 390
14-TCCU-20 20 14 7 60 0.73 415
14-TCCU-23 23 14 7 60 0.78 475
14-TCCU-25 25 14 7 80 0.85 540
14-TCCU-27 27 14 7 80 0.88 570
14-TCCU-29 29 14 7 80 0.90 600
14-TCCU-31 31 14 7 80 0.92 640
14-TCCU-32 32 14 7 80 0.94 660
14-TCCU-37 37 14 7 80 0.96 755

12-TCCU-2 2 12 7 45 0.36 90
12-TCCU-3 3 12 7 45 0.36 105
12-TCCU-4 4 12 7 45 0.40 135
12-TCCU-5 5 12 7 45 0.45 165
12-TCCU-6 6 12 7 45 0.50 195
CONTROL CABLES

12-TCCU-7 7 12 7 45 0.50 215


12-TCCU-8 8 12 7 45 0.58 260
12-TCCU-9 9 12 7 45 0.62 300
12-TCCU-10 10 12 7 60 0.66 325
12-TCCU-11 11 12 7 60 0.66 350
12-TCCU-12 12 12 7 60 0.68 375
12-TCCU-13 13 12 7 60 0.70 400
12-TCCU-14 14 12 7 60 0.73 425

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
518 Information on this sheet subject to change without notice.
20140902 Copyright © 2018, American Wire Group, Inc.
TFN, THWN or THHN Insulated Conductors
Overall Shield, Drain Wire, 600V

Item # Number of Size Number of Overall Nominal Weight


Conductors AWG Strands PVC Jacket Diameter /MFT
(mil) (in) (lb)
12-TCCU-15 15 12 7 60 0.76 455
12-TCCU-16 16 12 7 60 0.76 485
12-TCCU-17 17 12 7 60 0.79 515
12-TCCU-18 18 12 7 60 0.79 545
12-TCCU-19 19 12 7 60 0.79 565
12-TCCU-20 20 12 7 60 0.89 590
12-TCCU-23 23 12 7 60 0.93 690
12-TCCU-25 25 12 7 80 0.96 770
12-TCCU-27 27 12 7 80 1.00 840
12-TCCU-29 29 12 7 80 1.01 910
12-TCCU-31 31 12 7 80 1.06 950
12-TCCU-32 32 12 7 80 1.08 1000
12-TCCU-37 37 12 7 80 1.10 1090

10-TCCU-2 2 10 7 45 0.46 126


10-TCCU-3 3 10 7 45 0.46 155
10-TCCU-4 4 10 7 45 0.50 200
10-TCCU-5 5 10 7 60 0.58 265
10-TCCU-6 6 10 7 60 0.63 315
10-TCCU-7 7 10 7 60 0.63 345
10-TCCU-8 8 10 7 60 0.69 420
10-TCCU-9 9 10 7 60 0.73 450
10-TCCU-10 10 10 7 60 0.81 500
10-TCCU-11 11 10 7 60 0.81 540
10-TCCU-12 12 10 7 60 0.82 580
10-TCCU-13 13 10 7 80 0.89 680
10-TCCU-14 14 10 7 80 0.92 725
10-TCCU-15 15 10 7 80 0.95 745
10-TCCU-16 16 10 7 80 0.95 810
10-TCCU-17 17 10 7 80 1.02 860
10-TCCU-18 18 10 7 80 1.02 900
10-TCCU-19 19 10 7 80 1.02 940

CONTROL CABLES
10-TCCU-20 20 10 7 80 1.07 990
10-TCCU-23 23 10 7 80 1.12 1120
10-TCCU-25 25 10 7 80 1.19 1210
10-TCCU-27 27 10 7 80 1.22 1295
10-TCCU-29 29 10 7 80 1.23 1375
10-TCCU-31 31 10 7 80 1.29 1465
10-TCCU-32 32 10 7 80 1.31 1510
10-TCCU-37 37 10 7 80 1.36 1710

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 518
Copyright © 2018, American Wire Group, Inc. 20140902
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
THWN or THHN Insulated Conductors with Ground
PVC Jacket, 600V

Applications
As flame-retardant three or four conductor power cables rated 600V, 90°C in dry locations. 75°C in
wet locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC
cable is also approved for use in Class I and II, Division 2 hazardous locations. Cables may be in-
stalled in open air, in ducts or conduits, in tray or trough, or direct buried.

Construction
Individual conductors of stranded uncoated copper Type THWN or THHN, surface print phase identi-
fication. Three or four insulated conductors twisted with a Class B stranded uncoated copper
grounding conductor and fillers, cable tape, PVC jacket overall, surface printed.

Standards
• Listed by UL as Type TC Tray Cable per Article 336 of the NEC.
• Individual conductors UL listed as Type THWN or THHN.
• Overall jacket UL listed as Sunlight Resistant.
• Cables UL listed for Direct Burial.
• Cables UL listed for Open Wiring.
• Cables and color coding pass UL and IEEE-383 ribbon burner tests and ICEA 210.00 BTU/hr test.
Notes
• Ampacity in accordance with the National Electric Code for cables in uncovered cable tray without
maintained space and for cable in raceway or direct buried. 90°C conductor temperature for dry
locations, 75°C conductor temperature for wet locations, 30°C ambient temperature.
• Grounding conductor per UL Standard 1277 for Type TC Tray Cable.

Item# Number of Size Number of PVC Nylon Overall Nominal Grounding Weight
Conductors AWG or Strands Insulation Jacket PVC Jacket Diameter Conductor /MFT
KCM Thickness Thickness (mil) (in) Size AWG (lb)
(mil) (mil)
3 Conductor
TC3-8 3 8 7 30 5 60 0.62 10 315
TC3-6 3 6 7 30 5 60 0.70 8 445
TC3-4 3 4 7 40 6 80 0.88 8 675
TC3-2 3 2 7 40 6 80 1.01 6 995
TC3-1 3 1 19 50 7 80 1.14 6 1200
TC3-1/0 3 1/0 19 50 7 80 1.23 6 1480
TC3-2/0 3 2/0 19 50 7 80 1.32 6 1770
TC3-3/0 3 3/0 19 50 7 80 1.42 4 2180
TC3-4/0 3 4/0 19 50 7 80 1.56 4 2690

CONTROL CABLES
TC3-250 3 250 37 60 8 110 1.76 4 3225
TC3-350 3 350 37 60 8 110 1.98 3 4370
TC3-500 3 500 37 60 8 110 2.26 2 5960
TC3-750 3 750 61 70 9 110 2.71 1 9050
TC3-1000 3 1000 61 70 9 140 3.10 1/0 11720

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 519
Copyright © 2018, American Wire Group, Inc. 20140902
THWN or THHN with Ground
PVC Jacket, 600V

Item# Number of Size Number of PVC Nylon Overall Nominal Grounding Weight
Conductors AWG or Strands Insulation Jacket PVC Jacket Diameter Conductor /MFT
KCM Thickness Thickness (mil) (in) Size AWG (lb)
(mil) (mil)
4 Conductor
TC4-8 4 8 7 30 5 60 0.68 12 405
TC4-6 4 6 7 30 5 60 0.76 10 555
TC4-4 4 4 7 40 6 80 0.97 10 846
TC4-2 4 2 7 40 6 80 1.11 9 1256
TC4-1 4 1 19 50 7 80 1.26 9 1515
TC4-1/0 4 1/0 19 50 7 80 1.36 9 1913
TC4-2/0 4 2/0 19 50 7 80 1.47 9 2351
TC4-3/0 4 3/0 19 50 7 80 1.58 7 2760
TC4-4/0 4 4/0 19 50 7 110 1.79 7 3545
TC4-250 4 250 37 60 8 110 1.95 7 4148
TC4-350 4 350 37 60 8 110 2.20 6 5480
TC4-500 4 500 37 60 8 110 2.51 5 7924
TC4-750 4 750 61 70 9 140 3.07 4 11340
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
519 Information on this sheet subject to change without notice.
20140902 Copyright © 2018, American Wire Group, Inc.
Aluminum Three Conductor UL
Type TC 600V

Applications
These cables are specifically approved for power, control, lighting and signal circuits, in manufac-
turing, industrial and commercial installations. For use in direct burial, in cable trays, in raceways,
or where supported in outdoor locations by a messenger wire.
In cable tray in hazardous (classified) locations Class I, Division 2 per NEC, also as Class I circuits
per Article 725, and in Class II, Division 2, as permitted per NEC. When installed in accordance with
NEC 336.10(7), TC-ER marked cable is approved for use as open wiring between a cable tray and the
utilization equipment or device.

Construction
Assembly consisting of three or four insulated aluminum alloy AA8000 compact stranded conduc-
tors, cabled together with a bare equipment grounding conductor and non-hygroscopic fillers. The
sub-assembly is wrapped with binding tape and a PVC jacket is applied over the taped assembly.
PVC jacket is sunlight resistant, moisture resistant and flame retardant. This cable uses XHHW-2
conductors that are phase identified, including one insulated black conductor, one insulated white
conductor, and one insulated conductor with a single longitudinal red stripe. If required, a fourth in-
sulated conductor has a single longitudinal blue stripe. Phase conductors are insulated with cross-
linked polyethylene (XLPE) and rated for a maximum operating temperature of 90°C in dry and wet
locations, rated for 600 volts maximum operating voltage. Insulation is free of harmful heavy met-
als in compliance with RoHS, Directive 2002/95/EC.
Standards
• UL 1277 Type TC Tray Cable
• UL 44 Thermoset Insulated Conductors, Type XHHW-2 or RHW-2
• ICE A S-73-5 32
• NEMA WC57 Standard for Control Cables
• ICE A S-95-658 Standard for Non-shielded Power Cables Rated 2000 Volts or less
Notes
Terminates safely with industry standard dual rated terminals and connectors.

Item # Conductor No. of Grounding Insulation Jacket Nominal Nominal Package Ampacity Ampacity
Size Phase Conductor Thickness Thickness Diameter Weight Length 90°C 75°C
AWG Conductors AWG (mil) (mil) (in) (lb/MFT) (ft)
or kcmil or kcmil
A6-03XHPGTC-6 6 3 6 45 60 0.76 234 1000 75 50
A4-03XHPGTC-6 4 3 6 45 60 0.82 293 1000 75 65
A2-03XHPGTC-6 2 3 6 45 80 0.95 431 1000 100 90
A1-03XHPGTC-4 1 3 4 55 80 1.08 544 1000 115 100
A1/0-03XHPGTC-4 1/0 3 4 55 80 1.14 629 1000 135 120

CONTROL CABLES
A2/0-03XHPGTC-4 2/0 3 4 55 80 1.22 739 1000 150 135
A3/0-03XHPGTC-4 3/0 3 4 55 80 1.32 872 1000 175 155
A4/0-03XHPGTC-2 4/0 3 2 55 80 1.43 1061 1000 205 180
A250-03XHPGTC-2 250 3 2 65 80 1.57 1238 500 230 205
A300-03XHPGTC-2 300 3 2 65 110 1.74 1524 500 260 230
A300-03XHPGTC-1/0 300 3 1/0 65 110 1.74 1559 500 260 230
A350-03XHPGTC-2 350 3 2 65 110 1.83 1711 500 280 250
A400-03XHPGTC-1 400 3 1 65 110 1.94 1888 500 305 270
A500-03XHPGTC-1 500 3 1 65 110 2.11 2251 500 350 310
A600-03XHPGTC-1 600 3 1 80 110 2.34 2692 500 385 340
A700-03XHPGTC-1/0 700 3 1/0 80 110 2.47 3069 500 425 375
A750-03XHPGTC-1/0 750 3 1/0 80 110 2.54 3244 500 435 385
A900-03XHPGTC-250 900 3 250 80 140 2.80 4059 500 480 425
A900-03XHPGTC-400 900 3 400 80 140 2.91 4271 500 480 425
A900-03XHPGTC-750 900 3 750 80 140 3.19 5786 500 480 425

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 529
Copyright © 2018, American Wire Group, Inc. 20140626
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Aluminum Four Conductor UL
Type TC 600V

Applications
These cables are specifically approved for power, control, lighting and signal circuits, in manufac-
turing, industrial and commercial installations. For use in direct burial, in cable trays, in raceways,
or where supported in outdoor locations by a messenger wire.
In cable tray in hazardous (classified) locations Class I, Division 2 per NEC, also as Class I circuits
per Article 725, and in Class II, Division 2, as permitted per NEC. When installed in accordance with
NEC 336.10(7), TC-ER marked cable is approved for use as open wiring between a cable tray and the
utilization equipment or device.

Construction
Assembly consisting of three or four insulated aluminum alloy AA8000 compact stranded conduc-
tors, cabled together with a bare equipment grounding conductor and non-hygroscopic fillers. The
sub-assembly is wrapped with binding tape and a PVC jacket is applied over the taped assembly.
PVC jacket is sunlight resistant, moisture resistant and flame retardant. This cable uses XHHW-2
conductors that are phase identified, including one insulated black conductor, one insulated white
conductor, and one insulated conductor with a single longitudinal red stripe. If required, a fourth in-
sulated conductor has a single longitudinal blue stripe. Phase conductors are insulated with cross-
linked polyethylene (XLPE) and rated for a maximum operating temperature of 90°C in dry and wet
locations, rated for 600 volts maximum operating voltage. Insulation is free of harmful heavy met-
als in compliance with RoHS, Directive 2002/95/EC.

Standards
• UL 1277 Type TC Tray Cable
• UL 44 Thermoset Insulated Conductors, Type XHHW-2 or RHW-2
• ICE A S-73-5 32
• NEMA WC57 Standard for Control Cables
• ICE A S-95-658 Standard for Non-shielded Power Cables Rated 2000 Volts or less
Notes
Terminates safely with industry standard dual rated terminals and connectors.

Item # Conductor No. of Grounding Insulation Jacket Nominal Nominal Package Ampacity Ampacity
Size Phase Conductor Thickness Thickness Diameter Weight Length 90°C 75°C
AWG Conductors AWG (mil) (mil) (in) (lb/MFT) (ft)
or kcmil or kcmil
A6-04XHPGTC-6 6 4 6 45 80 0.87 315 1000 55 50
A4-04XHPGTC-6 4 4 6 45 80 0.95 400 1000 75 65
A2-04XHPGTC-6 2 4 6 45 80 1.06 526 1000 100 90
A1-04XHPGTC-4 1 4 4 55 80 1.21 683 1000 115 100
A1/0-04XHPGTC-4 1/0 4 4 55 80 1.28 797 1000 135 120
A2/0-04XHPGTC-4 2/0 4 4 55 80 1.36 928 1000 150 135

CONTROL CABLES
A3/0-04XHPGTC-4 3/0 4 4 55 80 1.46 1097 1000 175 155
A4/0-04XHPGTC-2 4/0 4 2 55 80 1.61 1346 1000 205 180
A250-04XHPGTC-1 250 4 1 65 110 1.83 1704 500 230 205
A300-04XHPGTC-1 300 4 1 65 110 1.93 1948 500 260 230
A350-04XHPGTC-1/0 350 4 1/0 65 110 2.05 2217 500 280 250
A400-04XHPGTC-1/0 400 4 1/0 65 110 2.15 2416 500 305 270
A500-04XHPGTC-2/0 500 4 2/0 65 110 2.34 2906 500 350 310
A600-04XHPGTC-2/0 600 4 2/0 80 110 2.59 3477 500 385 340
A700-04XHPGTC-2/0 700 4 2/0 80 140 2.80 4094 500 425 375
A750-04XHPGTC-3/0 750 4 3/0 80 140 2.88 4363 500 435 385
A750-04XHPGTC-750 750 4 750 80 140 3.34 5234 500 435 385
A900-04XHPGTC-4/0 900 4 4/0 80 140 3.10 5067 500 480 425
A900-04XHPGTC-250 900 4 250 80 140 3.13 5163 500 480 425
A900-04XHPGTC-400 900 4 400 80 140 3.28 5405 500 480 425
A900-04XHPGTC-750 900 4 750 80 140 3.53 5919 500 480 425

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 530
Copyright © 2018, American Wire Group, Inc. 20140626
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Thermocouple Cable
EX, JX, KX, TX
600V

Application
For use as a 600V, multi-pair thermocouple instrumentation cable where flame-retardance, and
moisture/chemical resistance is critical. Cable can be installed in free air, in raceways, or direct bur-
ial. The cable is also approved for wet or dry locations as well as Class 1 Division II industrial haz-
ardous locations per NEC 501-4(b) for (UL) Type Tray Cables (TC).
Temperature rating of 90°C wet or dry. Insulation provides excellent electrical, thermal, and physical
properties, excellent flame resistance and resistant to crush, compression, cuts and heat deforma-
tion. Also conductor insulation provides good low temperature (-40°C) cold bend characteristics.
Approved for direct burial.

Construction
• Conductor is thermocouple alloy per ANSI MC96.1 — 1982.
• Flame-retardant XLPE insulation.
• Conductors twisted together with a drain wire and aluminum mylar shield. Shielded pairs cabled
together with fillers as needed to form a round core. An overall aluminum mylar shield and drain
wire is applied over the core.
• Pairs are color coded per thermocouple type with pair number printed on the negative (red) con-
ductor. See chart below for specific color codes.
• Black, flame-retardant, sunlight resistant, Chlorinated Polyethylene (CPE) jacket. Available with
color coded jacket.
• Available with class B stranding per ASTM B174.
Standards
• Insulated Conductor — VW-1
• UL Type TC, 90°C Wet or Dry, 600V
• ICEA S-82-552, 90°C Wet or Dry, 600V.
• Passes UL 1277 Flame Test (70,000 BTU/hr).
• Passes UL 1202 Flame Test (70,000 BTU/hr).
• Passes IEEE 383 Flame Test (70,000 BTU/hr).
• Passes ICEA T-29-520 Flame Test (210,000 BTU/hr)
EX Color Code
• Chromel (Positive) — PURPLE
• Constantan (Negative) — RED
JX Color Code
• Iron (Positive) — WHITE
• Constantan (Negative) — RED
TX Color Code
• Copper (Positive) — BLUE
• Constantan (Negative) — RED
KX Color Code
• Chromel (Positive) — YELLOW

CONTROL CABLES
• Alumel (Negative) — RED
Notes
Dimensions and weights shown are nominal, subject to industry tolerances. Dimensions and
weights for other cable configurations are available upon request.

Options
• PVC Insulation, EPR Insulation
• PVC Jacket
• 300V
• Overall shield, shielded pairs overall shield

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 520
Copyright © 2018, American Wire Group, Inc. 20140110
Thermocouple Cable
EX, JX, KX, TX
600V

Item # Size AWG Number of Insulation Jacket Overall Weight


Shielded Pairs Thickness Thickness Diameter /MFT
(in) (in) (in) (lb)
ITC-20-1 20 1 0.025 0.045 0.270 35
ITC-20-2 20 2 0.025 0.045 0.035 70
ITC-20-3 20 3 0.025 0.045 0.450 85
ITC-20-4 20 4 0.025 0.045 0.500 105
ITC-20-6 20 6 0.025 0.045 0.600 160
ITC-20-8 20 8 0.025 0.045 0.670 210
ITC-20-10 20 10 0.025 0.045 0.735 240
ITC-20-12 20 12 0.025 0.045 0.790 280
ITC-20-16 20 16 0.025 0.045 0.890 360
ITC-20-24 20 24 0.025 0.045 1.060 500

ITC-18-1 18 1 0.025 0.045 0.300 50


ITC-18-2 18 2 0.025 0.045 0.480 90
ITC-18-3 18 3 0.025 0.045 0.510 115
ITC-18-4 18 4 0.025 0.045 0.595 165
ITC-18-6 18 6 0.025 0.045 0.670 220
ITC-18-8 18 8 0.025 0.045 0.750 280
ITC-18-10 18 10 0.025 0.045 0.820 340
ITC-18-12 18 12 0.025 0.045 0.930 430
ITC-18-16 18 16 0.025 0.045 1.045 540
ITC-18-24 18 24 0.025 0.045 1.235 760

ITC-16-1 16 1 0.025 0.045 0.325 60


ITC-16-2 16 2 0.025 0.045 0.570 130
ITC-16-3 16 3 0.025 0.045 0.600 160
ITC-16-4 16 4 0.025 0.045 0.660 200
ITC-16-6 16 6 0.025 0.045 0.740 270
ITC-16-8 16 8 0.025 0.045 0.880 380
ITC-16-10 16 10 0.025 0.045 0.970 460
ITC-16-12 16 12 0.025 0.045 1.035 530
ITC-16-16 16 16 0.025 0.045 1.165 570
ITC-16-24 16 24 0.025 0.045 1.400 960
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
520 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
IMSA 19-1 & 20-1
Traffic Control Cable
600V

Application
For use in signal systems in underground conduit/duct, or as aerial cable supported by a messen-
ger, or for installation in buildings.

Construction
• Solid Conductor or Stranded Conductor
• Polyethylene Insulation, 75°C, 600V
• 19-1: Black PVC Jacket
• 20-1: Black PE Jacket

Item # Size No. of Insulation Jacket Jacket O.D. O.D. Total Total
AWG Conductors Thickness Wall Wall Solid Solid Weight Weight
(in) Solid Stranded Solid Stranded Solid/MFT Stranded/MFT
(in) (in) (in) (in) (lb) (lb)
IMSA 19-1
IMSA-19-1-14-2 14 2 .025 0.045 0.045 0.329 0.347 62 67
IMSA-19-1-14-3 14 3 .025 0.045 0.045 0.346 0.366 74 79
IMSA-19-1-14-4 14 4 .025 0.045 0.045 0.377 0.398 93 99
IMSA-19-1-14-5 14 5 .025 0.045 0.045 0.410 0.435 114 122
IMSA-19-1-14-7 14 7 .025 0.045 0.045 0.445 0.472 146 156
IMSA-19-1-14-9 14 9 .025 0.045 0.060 0.517 0.580 188 216
IMSA-19-1-14-10 14 10 .025 0.060 0.060 0.591 0.627 221 235
IMSA-19-1-14-12 14 12 .025 0.060 0.060 0.608 0.606 255 272
IMSA-19-1-14-16 14 16 .025 0.060 0.060 0.672 0.715 328 350
IMSA-19-1-14-19 14 19 .025 0.060 0.060 0.707 0.752 377 402
IMSA-19-1-14-20 14 20 .025 0.060 0.060 0.743 0.791 398 424
IMSA-19-1-14-24 14 24 .025 0.060 0.080 0.823 0.917 470 535
IMSA-19-1-14-30 14 30 .025 0.080 0.080 0.911 0.968 605 644
IMSA-19-1-14-37 14 37 .025 0.080 0.080 0.979 1.042 727 774

IMSA-19-1-12-2 12 2 .030 0.045 0.045 0.383 0.405 89 95


IMSA-19-1-12-3 12 3 .030 0.045 0.045 0.404 0.428 107 113

CONTROL CABLES
IMSA-19-1-12-4 12 4 .030 0.045 0.045 0.442 0.468 135 143
IMSA-19-1-12-5 12 5 .030 0.045 0.045 0.483 0.513 168 178
IMSA-19-1-12-7 12 7 .030 0.060 0.060 0.556 0.589 232 246
IMSA-19-1-12-9 12 9 .030 0.060 0.060 0.645 0.684 297 315
IMSA-19-1-12-10 12 10 .030 0.060 0.060 0.699 0.743 324 343
IMSA-19-1-12-12 12 12 .030 0.060 0.060 0.720 0.766 377 399
IMSA-19-1-12-16 12 16 .030 0.060 0.080 0.799 0.891 490 552
IMSA-19-1-12-19 12 19 .030 0.080 0.080 0.882 0.937 598 633
IMSA-19-1-12-20 12 20 .030 0.080 0.080 0.926 0.985 630 667
IMSA-19-1-12-24 12 24 .030 0.080 0.080 1.025 1.091 745 789
IMSA-19-1-12-30 12 30 .030 0.080 0.080 1.084 1.154 904 956
IMSA-19-1-12-37 12 37 .030 0.080 0.080 1.168 1.245 1091 1155

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 521
Copyright © 2018, American Wire Group, Inc. 20140110
IMSA 19-1 & 20-1
Traffic Control Cable
600V

Item # Size No. of Insulation Jacket Jacket O.D. O.D. Total Total
AWG Conductors Thickness Wall Wall Solid Solid Weight Weight
(in) Solid Stranded Solid Stranded Solid/MFT Stranded/MFT
(in) (in) (in) (in) (lb) (lb)
IMSA 20-1
IMSA-20-1-14-2 14 2 .025 0.045 0.045 0.329 0.347 54 58
IMSA-20-1-14-3 14 3 .025 0.045 0.045 0.346 0.366 66 70
IMSA-20-1-14-4 14 4 .025 0.045 0.045 0.377 0.398 83 89
IMSA-20-1-14-5 14 5 .025 0.045 0.045 0.410 0.435 104 111
IMSA-20-1-14-7 14 7 .025 0.045 0.045 0.445 0.472 135 144
IMSA-20-1-14-9 14 9 .025 0.045 0.060 0.517 0.580 174 196
IMSA-20-1-14-10 14 10 .025 0.060 0.060 0.591 0.627 201 214
IMSA-20-1-14-12 14 12 .025 0.060 0.060 0.608 0.606 234 243
IMSA-20-1-14-16 14 16 .025 0.060 0.060 0.672 0.715 305 325
IMSA-20-1-14-19 14 19 .025 0.060 0.060 0.707 0.752 353 376
IMSA-20-1-14-20 14 20 .025 0.060 0.060 0.743 0.791 372 396
IMSA-20-1-14-24 14 24 .025 0.060 0.080 0.823 0.917 441 493
IMSA-20-1-14-30 14 30 .025 0.080 0.080 0.911 0.968 563 600
IMSA-20-1-14-37 14 37 .025 0.080 0.080 0.979 1.042 681 726

IMSA-20-1-12-2 12 2 .030 0.045 0.045 0.383 0.405 79 84


IMSA-20-1-12-3 12 3 .030 0.045 0.045 0.404 0.428 96 102
IMSA-20-1-12-4 12 4 .030 0.045 0.045 0.442 0.468 123 131
IMSA-20-1-12-5 12 5 .030 0.045 0.045 0.483 0.513 155 165
IMSA-20-1-12-7 12 7 .030 0.060 0.060 0.556 0.589 214 226
IMSA-20-1-12-9 12 9 .030 0.060 0.060 0.645 0.684 275 291
IMSA-20-1-12-10 12 10 .030 0.060 0.060 0.699 0.743 300 317
IMSA-20-1-12-12 12 12 .030 0.060 0.060 0.720 0.766 351 372
IMSA-20-1-12-16 12 16 .030 0.060 0.080 0.799 0.891 462 511
IMSA-20-1-12-19 12 19 .030 0.080 0.080 0.882 0.937 558 590
IMSA-20-1-12-20 12 20 .030 0.080 0.080 0.926 0.985 587 622
IMSA-20-1-12-24 12 24 .030 0.080 0.080 1.025 1.091 697 738
IMSA-20-1-12-30 12 30 .030 0.080 0.080 1.084 1.154 853 902
IMSA-20-1-12-37 12 37 .030 0.080 0.080 1.168 1.245 1036 1097
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
521 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
IMSA 19-1 & 20-1
Traffic Control Cable
Shipping Weights

Item # AWG/ IMSA 19-1 IMSA 19-1 IMSA 20-1 IMSA 20-1
Conductors Solid Stranded Solid Stranded
Weight /MFT Weight /MFT Weight /MFT Weight /MFT
(lb) (lb) (lb) (lb)
16/2 16/2 — 29 — 21
16/3 16/3 — 44 — 34
16/4 16/4 — 58 — 48
16/5 16/5 — 73 — 63
16/7 16/7 — 102 — 89
16/9 16/9 — 131 — 111
16/10 16/10 — 146 — 124
16/12 16/12 — 175 — 152

14/2 14/2 58 63 52 55
14/3 14/3 75 81 66 71
14/4 14/4 94 98 85 88
14/5 14/5 113 118 103 108
14/7 14/7 146 154 136 141
14/9 14/9 186 212 172 162
14/10 14/10 220 227 197 205
14/12 14/12 254 267 232 244
14/14 14/14 — 312 — 285
14/15 14/15 311 328 284 302
14/16 14/16 325 341 299 316
14/19 14/19 375 393 348 366
14/20 14/20 395 415 370 387
14/21 14/21 462 432 384 405
14/25 14/25 478 544 450 498
14/26 14/26 497 566 468 518

12/2 12/2 82 87 74 77
12/3 12/3 108 113 99 103
12/4 12/4 135 141 124 130
12/5 12/5 163 172 152 159
12/7 12/7 237 244 212 222

CONTROL CABLES
12/9 12/9 281 310 273 284
12/10 12/10 312 338 296 309
12/12 12/12 372 393 346 367
12/16 12/16 449 541 461 501
12/19 12/19 599 625 547 582
12/20 12/20 631 658 576 618
12/21 12/21 663 691 605 643
12/25 12/25 789 822 720 751

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 521
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
IMSA 50-2
Loop Detector Lead-In Wire
600V

Application
Used in municipal signal systems as lead-in cable or for use in communication circuits where a low
capacitance is needed, suitable for underground conduit, as aerial cable supported by messenger,
or in raceways in buildings.

Construction
• Unilay stranded tin coated, annealed copper per ASTM-B-33
• Twisted pair with overall shield and drain wire
• Insulation is high molecular weight PE per UL 758, black and clear
• Aluminum/Polyester tape shield helically applied
• Polyetheylene Jacket, black
Standards
IMSA Spec No. 50-2-1984.
Also available: NCDOT 1993 and NCDOT 06-031110.

Item # Size Stranding Nominal Nominal Nominal


AWG Jacket O.D. Weight
Thickness (in) /MFT
(in) (lb)
IMSA-50-2-18 18 19 .032 .284 31
IMSA-50-2-16 16 19 .032 .306 39
IMSA-50-2-14 14 19 .032 .338 54
IMSA-50-2-12 12 19 .032 .376 75

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 522
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
IMSA 51-1 THHN
Loop Detector Lead-In Wire
600V

Application
Designed for use in municipal signal systems as “Loop Detector Wire.” These wires are installed in
pavement saw cuts at traffic intersections to detect the presence of motor vehicles. The signal is
sent to a traffic signal controller to activate the light changes.

Construction
Conductors: Stranded, uncoated annealed copper per ASTM B-8. Other strandings and tinned con-
ductors available upon special request.
Insulation: Heat stabilized PVC with a nylon jacket per IMSA Specification No. 51.1 paragraph 4 and
6. Insulation color is black.

Standards
Dimensionals physicals and electricals per IMSA SPECIFICATION NO. 51.1

Item # Size Number of Strands Insulation Jacket Overall Weight


AWG Strands O.D. Thickness Wall Diameter /MFT
(in) (in) (in) (in) (lb)
IMSA-51-1-18 18 7 .0152 .015 .004 .085 7
IMSA-51-1-16 16 7 .0192 .015 .004 .097 11
IMSA-51-1-14 14 7 .0242 .015 .004 .112 16
IMSA-51-1-12 12 7 .0305 .015 .004 .131 24
IMSA-51-1-10 10 7 .0385 .015 .004 .165 38

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 523
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
IMSA 51-3
Loop Detector Wire
600V

Application
Designed for use in municipal signal systems as "Loop Detector Wire". These wires are installed in
pavement saw cuts at traffic intersections to detect the presence of motor vehicles. The signal is
sent to a traffic signal controller to activate the light changes.

Construction
Conductors: Solid or stranded, bare, uncoated copper with separator per ASTM B03 or B08. Other
strandings and tinned conductors available upon special request.
Insulation: Cross-linked polyethylene per IMSA Specification No. 51-3, paragraph 4. Insulation color
is black.

Standards
Tests: Dimensionals, physicals, and electricals per IMSA Specification No. 51-3.

Note
The data listed is approximate and subject to normal manufacturing tolerances. Alternate construc-
tions or materials may be available.

Item # Size Number of Strands Insulation Overall Weight


AWG Strands O.D. Thickness Diameter /MFT
(in) (in) (in) (lb)
IMSA-51-3-14-S 14 Solid N/A .030 .125 17
IMSA-51-3-14-7 14 7 .0242 .0.0 .135 18
IMSA-51-3-14-19 14 19 .0147 .030 .135 18
IMSA-51-3-12-S 12 Solid N/A .030 .145 25
IMSA-51-3-12-7 12 7 .0305 .030 .155 26
IMSA-51-3-10-S 10 Solid N/A .030 .165 38
IMSA-51-3-107 10 7 .0385 .030 .180 39
IMSA-51-3-87 8 7 .0486 .045 .240 66
IMSA-51-3-67 6 7 .0612 .045 .275 99
IMSA-51-3-47 4 7 .0772 .045 .325 151
IMSA-51-3-27 2 7 .0974 .045 .380 232

Shipping Weights
Item # Size AWG IMSA Spec No. Description Weight /MFT

CONTROL CABLES
Insulation Type (lb)
51-3-14 14 51-3 Tinned Copper STR XLPE Insulation 17
51-3-12 12 51-3 Tinned Copper STR XLPE Insulation 29

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 524
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
IMSA 51-5
Inductant Loop Detector Cable
600V

Application
Used in road pavements to detect vehicles for the purpose of changing signals or determining
amount of traffic flow.

Construction
• Single conductor, 600V
• PVC/Nylon Insulation in PVC or PE tube jacket, 75°C
• AWG #14 (2.08mm) one copper conductor per ASTM B-3)
• 19 strand concentric or bunch stranding
• 15 mils of black PVC per UL 62
• Jacket is clear nylon per ASTM D-4066
• Encasing tube is PVC or HDPE compound
• Temperature rating: 60°C
• Voltage rating: 600V
Specifications
IMSA Spec No. 51-5-1984.
Also available: NCDOT 199 and NCDOT 06-24273.

Option
• XLPE Insulation

Item # Size Number of O.D. O.D. O.D. PVC PE


AWG Strands Outside Inside Wall Total Weight Total Weight
Diameter Diameter Thickness /MFT /MFT
(in) (in) (in) (lb) (lb)
IMSA-51-5-14 14 19 .250 .190 .030 30.00 25.00
IMSA-51-5-12 12 19 .260 .200 .030 38.00 34.00

Shipping Weights
Item # Size AWG IMSA Spec No. Description Encasing Weight /MFT
Insulation Type Tube (lb)
51-5 XLPE/PVC 14 14 51-5 Bare CU STR XLPE Insulation PVC 31
51-5 XLPE/PVC 12 12 51-5 Bare CU STR XLPE Insulation PVC 41
51-5 XLPE/HDPE 14 14 51-5 Bare CU STR XLPE Insulation HDPE 33
51-5 XLPE/HDPE 12 12 51-5 Bare CU STR XLPE Insulation HDPE 43
51-5 PVC/PVC 14 14 51-5 Bare CU STR PVC/Nylon Insulation PVC 27
51-5 PVC/PVC 12 12 51-5 Bare CU STR PVC/Nylon Insulation PVC 36

CONTROL CABLES
51-5 PVC/HDPE 14 14 51-5 Bare CU STR PVC/Nylon Insulation HDPE 29
51-5 PVC/HDPE 12 12 51-5 Bare CU STR PVC/Nylon Insulation HDPE 39

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 525
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
IMSA Cable
Selection Guide

Item # IMSA Voltage Applications Installation Conductor Mechanical


Spec No. Rating Configuration Characteristics
19-1 19-1 600 Traffic Signal Aerial or Duct Cabled PVC Outer Jacket
Fire Protective Signal Conductors
19-2 19-2 600 Traffic Signal Aerial or Duct Twisted Pairs Shielded
Fire Protective Signal PVC Outer Jacket
19-3 19-3 600 Traffic Signal Figure-8 Aerial Cabled PVC Outer Jacket
Fire Protective Signal Integral Msgr. Conductors
19-4 19-4 600 Traffic Signal Figure-8 Aerial Twisted Pairs Shielded
Fire Protective Signal Integral Msgr. PVC Outer Jacket
19-5 19-5 600 Traffic Signal Aerial, Duct or Buried Cabled Conductors Shielded
Fire Protective Signal PE Inner &
PVC Outer Jackets
16-6 19-6 600 Traffic Signal Aerial, Duct or Buried Twisted Pairs Shielded,
Fire Protective Signal PE Inner &
PVC Outer Jackets
20-1 20-1 600 Traffic Signal Aerial or Duct Cabled Conductors PE Outer Jacket
Fire Protective Signal
20-2 20-2 600 Traffic Signal, Aerial or Duct Twisted Pairs Shielded
Fire Protective Signal PE Outer Jacket
20-3 20-3 600 Traffic Signal Figure-8 Aerial Cabled Conductors PE Outer Jacket
Fire Protective Signal Integral Msgr.
20-4 20-4 600 Traffic Signal Figure-8 Aerial Twisted Pairs Shielded
Fire Protective Signal Integral Msgr. PE Outer Jacket
20-5 20-5 600 Traffic Signal Aerial, Duct or Buried Cabled Conductors Shielded, PE Inner
Fire Protective Signal & Outer Jacket
20-6 20-6 600 Traffic Signal Aerial, Duct or Buried Twisted Pairs Shielded, PE Inner
Fire Protective Signal & Outer Jacket
26-3 26-3 — Signal Systems Aerial Self-Supporting Single Hard-Drawn High Density Poly-
Copper Conductor ethylene
(HDPE)Insulation
28-3 28-3 — Signal Systems Aerial Self-Supporting Single Copper-Covered HDPE Insulation
Steel Conductor
29-1 29-1 — Signal Systems Aerial Self-Supporting C Line Wire (Parallel) HDPE Insulation
2 Hard-Drawn

CONTROL CABLES
Copper Conductors
29-2 29-2 — Signal Systems Aerial Self-Supporting C Line Wire (Parallel HDPE Insulation
2 Copper-Covered
Steel Conductors
29-3 29-3 — Signal Systems Aerial Self-Supporting C Line Wire (Parallel) HDPE Insulation
2 Hard-Drawn PVC Outer Jacket
Copper Conductors
29-4 29-4 — Signal Systems Aerial Self-Supporting C Line Wire (Parallel) HDPE Insulation
2 Copper-Covered PVC Outer Jacket
Steel Conductors
39-2 39-2 300 Fire Protective Signal Aerial, Duct or Twisted Pairs Shielded
Traffic Communications Building Raceway PVC Outer Jacket
Data Acquisition

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 526
Copyright © 2018, American Wire Group, Inc. 20140110
IMSA Cable
Selection Guide

Item # IMSA Voltage Applications Installation Conductor Mechanical


Spec No. Rating Configuration Characteristics
39-4 39-4 300 Traffic Communications Figure-8 Aerial Twisted Pairs Shielded
Data Acquisition Integral Msgr. PVC Outer Jacket
39-6 39-6 300 Fire Protective Signal Aerial, Duct or Twisted Pairs Shielded
Traffic Communications Building Raceway PE Inner &
Data Acquisition PVC Outer Jackets
40-2 40-2 300 Fire Protective Signal Aerial, Duct or Twisted Pairs Shielded
Traffic Communications Building Raceway PE Outer Jacket
Data Acquisition
40-4 40-4 300 Traffic Communications Figure-8 Aerial Twisted Pairs Shielded
Data Acquisition Integral Msgr. PE Outer Jacket
40-6 40-6 300 Fire Protective Signal Aerial, Duct, Buried or Twisted Pairs Shielded
Traffic Communications Building Raceway PE Inner &
Data Acquisition Outer Jacket
50-2 50-2 600 Signal Loop Detector Duct or Buried Twisted Pairs PE Insulation
Lead-In Feeder PE Outer Jacket
51-1 51-1 600 Inductance Loop Detector Duct Single Conductor PVC/Nylon
Insulation
51-3 51-3 600 Inductance Loop Detector Duct or Buried Single Conductor Cross-Linked
PE Insulation
51-5 51-5 600 Inductance Loop Detector Duct or Buried Single Conductor PVC/Nylon
Insulation in
PVC or PE Tube
51-7 51-7 600 Inductance Loop Detector Duct or Buried Single Conductor Cross-Linked
PE Insulation in
PVC or PE Tube
59-2 59-2 300 Fire Protective Signal Aerial or Duct Twisted Pairs Filled Core,
Traffic Communications Shielded
Data Acquisition PVC Outer Jacket
59-4 59-4 300 Traffic Communications Figure-8 Aerial Twisted Pairs Filled Core,
Data Acquisition Integral Msgr. Shielded
PVC Outer Jacket
59-6 59-6 300 Fire Protective Signal Aerial, Twisted Pairs Filled Core
Traffic Communications Duct or Buried Shielded
Data Acquisition PE Inner Jacket
CONTROL CABLES

PVC Outer Jacket


60-2 60-2 300 Fire Protective Signal Aerial or Duct Twisted Pairs Filled Core
Traffic Communications Shielded
Data Acquisition PE Outer Jacket
60-4 60-4 300 Traffic Communications Figure-8 Aeria Twisted Pairs Filled Core
Data Acquisition Integral Msgr. Shielded
PE Outer Jacket
60-6 60-6 300 Fire Protective Signal Aerial, Twisted Pairs Filled Core,
Traffic Communications Duct or Buried Shielded,
Data Acquisition PE Inner and
PE Outer Jacket
70-1 70-1 — Traffic Communications Aerial, 2 to 72 fibers All Dialectric
Duct or Buried
70-5 70-5 — Traffic Communications Duct or Buried 2 to 72 fibers Armored

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
526 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
IMSA Cable
Color Code Chart
Method 1

This color code system employs six (6) different base colors alternating through a series of 21 conductors. In this series, the last 15 con-
ductors are marked with tracers of contrasting colors. The color sequence is repeated in regular sequence as necessary for cable configu-
rations employing more than twenty-one (21) conductors.

Item # Conductor Base Tracer Item # Conductor Base Tracer


Number Color Color Number Color Color

IMSA-CC-1 1 Black N/A IMSA-CC-12 12 Black White


IMSA-CC-2 2 White N/A IMSA-CC-13 13 Red White
IMSA-CC-3 3 Red N/A IMSA-CC-14 14 Green White
IMSA-CC-4 4 Green N/A IMSA-CC-15 15 Blue White
IMSA-CC-5 5 Orange N/A IMSA-CC-16 16 Black Red
IMSA-CC-6 6 Blue N/A IMSA-CC-17 17 White Red
IMSA-CC-7 7 White Black IMSA-CC-18 18 Orange Red
IMSA-CC-8 8 Red Black IMSA-CC-19 19 Blue Red
IMSA-CC-9 9 Green Black IMSA-CC-20 20 Red Green
IMSA-CC-10 10 Orange Black IMSA-CC-21 21 Orange Green
IMSA-CC-11 11 Blue Black

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 527
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
IMSA Cable
XHHX-2 & USE-2
Shipping Weights

XHHX-2 Shipping Weights USE-2 Shipping Weights


Item # Size AWG Weight Item # Size AWG Weight
/MFT /MFT
(lb) (lb)
IMSA-X14 14 18 IMSA-U14 14 23
IMSA-X12 12 25 IMSA-U12 12 30
IMSA-X10 10 40 IMSA-U10 10 43
IMSA-X8 8 67 IMSA-U8 8 72
IMSA-X6 6 100 IMSA-U6 6 106
IMSA-X4 4 150 IMSA-U4 4 157
IMSA-X2 2 230 IMSA-U2 2 237
IMSA-X1 1 290 IMSA-U1 1 304

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 528
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Wire & Cable
Methods of Color Coding

Used to identify conductors for point-to-point wiring and for circuit diagrams. Color codes are used to establish a standard for use by dif-
ferent manufacturers.
The first color code used colored tracers in a solid colored braid. Most control cable color codes are adaptations of this method. Later, for
ease and convenience, ink printed versions were developed.
Telephone requirements established special color codes.

Color Codes (ICEA Methods)


ICEA/NEMA Method 1 ICEA/NEMA Method 5
Colored insulation with contrasting ink tracers as required. Six A color coding using braids. Also sometimes specified using
different insulation colors and four different colored ink trac- colored insulation and contrasting tracers as an extension of
ers are used to provide positive identification through 21 con- Method I to eliminate duplicate conductors. Up to 127 positive
ductors. The same identification sequence is repeated for conductor coding are available with this method. Usually
cables containing more than 21 conductors. specified as per: ICEA5-61-402 Table 5-1 or ICEA 5-19-81 Table
ICEA/NEMA Method 2 5-2.
A neutral colored compound is used with single or double spi- ICEA/NEMA Method 6
ral ink tracers as required to provide positive identification A color coding whereby one conductor in each layer is identi-
through 21 conductors. The identification sequence is repeated fied by a braid, tape, ridge, stripe or color.
for cables containing more than 21 conductors. ICEA/NEMA Paired Color Code
ICEA/NEMA Method 3 A coding whereby one leg of all pairs is coded white and its
A neutral or single colored insulation compound is surface ink mate is coded in accordance with the first 21 conductors of
printed with both conductor number and color designation to Method 1, omitting white and repeating the sequence as nec-
provide positive identification through 21 conductors. The essary.
identification sequence is repeated for colors containing more Telephone Paired Color Code
than 21 conductors. Five colors are paired with each of five mate colors to give 25
ICEA/NEMA Method 4 identified pairs. The color sequences are repeated for more
A neutral or single colored insulation compound is surface ink than 25 pairs using colored binder strings for group identifica-
printed with conductor number to provide positive conductor tion.
identification through 21 conductors. The identification se-
quence is repeated for cables containing more than 21 con-
ductors.
Note: UL and the NEC restrict the use of green and white as colors and stripes. Special color codes are available to meet these requirements. One method is
ICEA Method E-2 which is similar to Method 1 and ICEA Method E-4 which is similar to Method 2.

CONTROL CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. B
Copyright © 2018, American Wire Group, Inc. 20140110
Wire & Cable
Color Coding Charts

ICEA Method 1, Table E-1 ICEA Method 1, Table E-2


(Colored compound with tracers) (Colored compound with tracers)

Conductor Background Tracer Conductor Background Tracer


Number or Base Color Color Number or Base Color Color
1* Black – 1* Black –
2 White – 2 Red –
3 Red – 3 Blue –
4 Green – 4 Orange –
5 Orange – 5 Yellow –
6 Blue – 6 Brown –
7 White Black 7 Red Black
ICEA Method 2, Table E-1 8 Blue Black
8 Red Black
(Neutral colored compound with tracers)
9 Green Black 9 Orange Black
10 Orange Black Conductor First Second 10 Yellow Black
11 Blue Black Number Tracer Tracer 11 Brown Black
12 Black White Color Color 12 Black Red
13 Red White (Wide (Narrow 13 Blue Red
Tracer) Tracer)
14 Green White 14 Orange Red
1* Black –
15 Blue White 15 Yellow Red
2 White –
16 Black Red 16 Brown Red
3 Red –
17 White Red 17 Black Blue
4 Green –
18 Orange Red 18 Red Blue
5 Orange –
19 Blue Red 19 Orange Blue
6 Blue –
20 Red Green 20 Yellow Blue
7 White Black
21 Orange Green 21 Brown Blue
8 Red Black
*This conductor is in the inside of the assembly. 22 Black Orange
9 Green Black
23 Red Orange
10 Orange Black
24 Blue Orange
11 Blue Black
25 Yellow Orange
12 Black White
26 Brown Orange
13 Red White
27 Black Yellow
14 Green White
28 Red Yellow
15 Blue White
29 Blue Yellow
16 Black Red
30 Orange Yellow
17 White Red
CONTROL CABLES

31 Brown Yellow
18 Orange Red
32 Black Brown
19 Blue Red
33 Red Brown
20 Red Green
34 Blue Brown
21 Orange Green
35 Orange Brown
*This conductor is in the inside of the assembly.
36 Yellow Brown
*This conductor is in the inside of the assembly.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
B Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Wire & Cable
Color Coding Charts

ICEA Method 1, Table E-2 ICEA Method 3 ICEA Method 4


(Neutral colored compound with tracers) (Neutral or single color compound with surface (Neutral or single color compound with surface
printing of numbers and color designations) printing of numbers)
Conductor Background Tracer
Number or Base Color Color Conductor Printed Legend Conductor Printed Legend
1* Black - Number Number
2 Red - 1* 1 – Black 1* 1
3 Blue - 2 2 – White 2 2
4 Orange - 3 3 – Red 3 3
5 Yellow - 4 4 – Green 4 4
6 Brown - 5 5 – Orange 5 5
7 Red Black 6 6 – Blue 6 6
8 Blue Black 7 7 – White–Black 7 7
9 Orange Black 8 8 – Red–Black 8 8
10 Yellow Black 9 9 – Green–Black 9 9
11 Brown Black 10 10 – Orange–Black 10 10
12 Black Red 11 11 – Blue–Black 11 11
13 Blue Red 12 12 – Black–White 12 12
14 Orange Red 13 13 – Red–White 13 13
15 Yellow Red 14 14 – Green–White 14 14
16 Brown Red 15 15 – Blue–White 15 15
17 Black Blue 16 16 – Black–Red 16 16
18 Red Blue 17 17 – White–Red 17 17
19 Orange Blue 18 18 – Orange–Red 18 18
20 Yellow Blue 19 19 – Blue–Red 19 19
21 Brown Blue 20 20 – Red–Green 20 20
22 Black Orange 21 21 – Orange–Green 21 21
*This conductor is in the inside of the assembly. *This conductor is in the inside of the assembly.
23 Red Orange
24 Blue Orange
25 Yellow Orange
26 Brown Orange
27 Black Yellow
28 Red Yellow
29 Blue Yellow
30 Orange Yellow

CONTROL CABLES
31 Brown Yellow
32 Black Brown
33 Red Brown
34 Blue Brown
35 Orange Brown
36 Yellow Brown
*This conductor is in the inside of the assembly.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. B
Copyright © 2018, American Wire Group, Inc. 20140110
Wire & Cable
Color Coding Charts

ICEA Method 5
(Colored compounds with tracers)

Cond. Background First Second Cond. Background First Second Cond. Background First Second
Number or Tracer Tracer Number or Tracer Tracer Number or Tracer Tracer
Base Color Color Color Base Color Color Color Base Color Color Color
1* Black – – 44 Black White Blue 87 Black Orange –
2 White – 45 White Black Blue 88 White Orange –
3 Red – – 46 Red White Blue 89 Red Orange –
4 Green – – 47 Green Orange Red 90 Green Orange –
5 Orange – – 48 Orange Red Blue 91 Blue Orange –
6 Blue – – 49 Blue Red Orange 92 Black Blue –
7 White Black – 50 Black Orange Red 93 White Blue –
8 Red Black – 51 White Black Orange 94 Red Blue –
9 Green Black – 52 Red Orange Black 95 Green Blue –
10 Orange Black – 53 Green Red Blue 96 Orange Blue –
11 Blue Black – 54 Orange Black Blue 97 Yellow – –
12 Black White – 55 Blue Black Orange 98 Yellow Black –
13 Red White – 56 Black Orange Green 99 Yellow White –
14 Green White – 57 White Orange Green 100 Yellow Red –
15 Blue White – 58 Red Orange Green 101 Yellow Green –
16 Black Red – 59 Green Black Blue 102 Yellow Orange –
17 White Red – 60 Orange Green Blue 103 Yellow Blue –
18 Orange Red – 61 Blue Green Orange 104 Black Yellow –
19 Blue Red – 62 Black Red Blue 105 White Yellow –
20 Red Green – 63 White Orange Blue 106 Red Yellow –
21 Orange Green – 64 Red Black Blue 107 Green Yellow –
22 Black White Red 65 Green Orange Blue 108 Orange Yellow –
23 White Black Red 66 Orange White Red 109 Blue Yellow –
24 Orange Black White 67 Blue White Red 110 Black Yellow Red
25 Blue Black White 68 Black Green Blue 111 White Yellow Red
26 Red Black White 69 White Green Blue 112 Green Yellow Red
27 Orange Black White 70 Red Green Blue 113 Orange Yellow Red
28 Black Red Green 71 Green White Red 114 Blue Yellow Red
29 White Red Green 72 Orange Red Black 115 Black Yellow White
30 Red Black Green 73 Blue Red Black 116 Red Yellow White
CONTROL CABLES

31 Green Black Orange 74 Black Orange Blue 117 Green Yellow White
32 Orange Black Green 75 Red Orange Blue 118 Orange Yellow White
33 Blue White Orange 76 Green Red Black 119 Blue Yellow White
34 Black White Orange 77 Orange White Green 120 Black Yellow Green
35 White Red Orange 78 Blue White Green 121 White Yellow Green
36 Orange White Blue 79 Red White Orange 122 Red Yellow Green
37 White Red Blue 80 Green White Orange 123 Orange Yellow Green
38 Black White Green 81 Blue Black Green 124 Blue Yellow Green
39 White Black Green 82 Orange White – 125 Black Yellow Blue
40 Red White Green 83 Green Red – 126 White Yellow Blue
41 Green White Blue 84 Black Green – 127 Red Yellow Blue
42 Orange Red Green 85 White Green – *This conductor is in the inside of the assembly.
43 Blue Red Green 86 Blue Green –

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
B Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
FIBER OPTIC CABLES
Table of Contents

OPGW Optical Ground Wire..................................................................................................607


Installation Manual for OPGW Cable ...................................................................................608
OPGW Cable & System Information Guide for Hardware Selection .................................602
ADSS Fiber Optic Cable ........................................................................................................603
Loose Tube Fiber Optic Cable................................................................................................604
Loose Tube Fiber Optic Cable for Direct Burial....................................................................606
HDPE Conduit.........................................................................................................................605
High Density Polyethylene Duct ...........................................................................................609

FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 600
Copyright © 2018, American Wire Group, Inc. 20170321
NOTES
FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
OPGW Optical Ground Wire

Applications
OPGW cable is suited for installation on transmission lines with the double function of a ground wire
(designed to replace traditional static or shield wires) and a communication wire. OPGW conducts
short circuit current and provide lightning resistance as it “shields” conductors, while providing a
telecommunications path for internal as well as third party communications. OPGW must be capable
of withstanding the mechanical and environmental stresses inflicted on overhead cables (such those
caused by wind or ice). OPGW must also be capable of handling electrical faults on the transmission
line by providing a path to ground yet preventing damage to the delicate optical fibers inside the cable.
OPGW (Optical Ground Wire) with a stainless steel central tube is preferred for its compact size and
ability to house up to 72 fibers in a diameter starting at only 12mm. Its small profile offers an excep-
tional solution to the diameter and weight concerns on many of today’s overloaded transmission
towers where an existing shield wire needs to be replaced with an OPGW cable.

Construction
OPGW cable has two constructions:
Central loose tube type:The fibers are placed loosely in a sealed and water resistant central, alu-
minum tube filled with water blocking gel. This tube provides protection to the fiber during installa-
tion and operation under severe environmental conditions. The stainless steel tube may also be
aluminum-clad steel depending on the engineering requirements. The stainless optical tube is lo-
cated at the center of the cable protected by single or multiple layers of aluminum clad steel, alu-
minum alloy wires, or steel wires. The metallic wires provide mechanical strength to withstand
severe installation and operating conditions, while achieving conductivity to control temperature
rise during short circuit conditions.
Each optical fiber is clearly distinguishable utilizing a fiber identification system consisting of color-
ing and the number of ring marks on it. This compact design features high mechanical strength and
fault current rating within a smaller diameter. The smaller diameter also results in excellent sag ten-
sion performance.
Multi loose tube type: The fibers is placed loosely in a sealed and water resistant stainless steel
tube filled with water blocking gel. Two or three stainless steel optical tubes are helically stranded in
the inner layer of a multiple-layer cable. The multi loose tube type is designed mostly for very high
fiber count requirement over 48 with the maximum fiber count reaching 144. The multi loose tube
type can meet the requirement of huge cross and large current capacity.
The optical fiber is made of high pure silica and germanium doped silica. UV curable acrylate mate-
rial is applied over fiber cladding as optical fiber primary protective coating. The detail data of opti-
cal fiber performance are shown in the following table.
Optical fiber uses special spun device successfully controlled the value of PMD, and makes sure
that it can keep stable in cabling.

Standards • IEC 61232 Aluminum – clad steel wire for elec-


• IEC 60793-1 Optical fiber Part 1: Generic speci- trical purposes
fications • IEC 60104 Aluminum magnesium-silicon alloy
• IEC 60793-2 Optical fiber Part 2: Product speci- wire for overhead line conductors
fications • IEC 61089 Round wire concentric lay overhead
• ITU-T G.652 Characteristics of a single-mode electrical stranded conductors
optical fiber cable • Fiber is Corning SMF-28e+ Optical Fiber
• ITU-T G.655 Characteristics of a non-zero dis-
persion-shifted single-mode optical fiber and Options
Cable • Hardware for Installation
• EIA/TIA 598 Color code of fiber optic cables Notes
• IEC 60794-4-10 Aerial optical cables along • Reel lengths must be defined at time of pur-

FIBER OPTIC CABLES


electrical power lines – Family specification chase to assist client with reducing waste, and
for OPGW to reduce splicing required during installation.
• IEC 60794-1-2 Optical fiber cables-Part 1-2: • Please contact AWG for full detailed technical
Generic specification - Basic optical cable test specifications, including PLS CADD data or
procedures Stress Creep data.
• IEEE1138-2009 IEEE Standard for testing and
performance for optical ground wire (OPGW)
for use on electric utility power lines

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 607
Copyright © 2018, American Wire Group, Inc. 20150407
OPGW Optical Ground Wire

Item # Fibers Fault Total Total Overall Overall Weight Weight RBS RBS
Current Conductor Conductor Diameter Diameter (lb/ft) (kg/km) (lb) (kb)
(KA2sec) Area Area (in) (mm)
(in2) (mm2)
SINGLE STAINLESS STEEL TUBE
OPGW-2S1/24
(M85/R77-51) 24 51 0.1273 85.05 0.484 12.3 0.321 0.478 17390 7888
OPGW-2S2/18
(M80/R72-46) 36 46 0.1202 80.34 0.484 12.3 0.313 0.466 16107 7306
OPGW-2S1/24
(M107/R76-97) 24 97 0.1603 107.13 0.544 13.8 0.338 0.503 16984 7704
OPGW-2S1/24
(M115/R69-121) 24 121 0.1722 115.05 0.563 14.3 0.328 0.488 15611 7081
OPGW-2S42/48
(M137/R107-147) 96 147 0.2046 136.72 0.630 16 0.472 0.702 24048 10908
OPGW-2S2/48
(M137/R100-154) 96 154 0.2046 136.72 0.630 16 0.450 0.67 22384 10153
OPGW-2S2/48
(M150/R107-186) 96 186 0.2246 150.11 0.662 16.8 0.499 0.742 24183 10969
OPGW-2S3/48
(M129/R97-134) 144 134 0.1926 128.68 0.630 16 0.449 0.668 21865 9918
OPGW-2S3/48
(M129/R98-134) 144 134 0.1926 128.68 0.630 16 0.449 0.668 21934 9949
OPGW-2S3/48
(M141/R105-161) 144 161 0.2114 141.29 0.662 16.8 0.499 0.743 23598 10704
FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
607 Information on this sheet subject to change without notice.
20150407 Copyright © 2018, American Wire Group, Inc.
OPGW Optical Ground Wire

Item # Fibers Fault Total Total Overall Overall Weight Weight RBS RBS
Current Conductor Conductor Diameter Diameter (lb/ft) (kg/km) (lb) (kb)
(KA2sec) Area Area (in) (mm)
(in2) (mm2)
ALUMINUM TUBE
OPGW(LAL_Tube)-1S8
(M80/R72-43) 8 43 0.1195 79.88 0.496 12.6 0.300 0.447 16197 7347
OPGW(LAL_Tube)-1S8
(M87/R50-63) 8 63 0.1195 79.88 0.516 13.1 0.272 0.404 11338 5143
OPGW(LAL_Tube)-1S8
(M113/R102-88) 8 88 0.1694 113.19 0.571 14.5 0.421 0.626 22902 10388
OPGW(LAL_Tube)-1S8
(M113/R69-101) 8 101 0.1694 113.19 0.571 14.5 0.369 0.549 15410 6990
OPGW(LAL_Tube)-1S12
(M80/R72-43) 12 43 0.1195 79.88 0.496 12.6 0.301 0.448 16219 7357
OPGW(LAL_Tube)-1S12
(M87/R50-63) 12 63 0.1195 79.88 0.516 13.1 0.272 0.404 11338 5143
OPGW(L-AL_Tube)-1S12
(M100/R91-67) 12 67 0.1494 99.86 0.544 13.8 0.376 0.56 20426 9265
OPGW(LAL_Tube)-1S12
(M100/R61-78) 12 78 0.1461 97.62 0.544 13.8 0.329 0.49 13790 6255
OPGW(LAL_Tube)-1S24
(M99/R86-69) 24 69 0.1481 98.96 0.540 13.7 0.362 0.538 19257 8735
OPGW(LAL_Tube)-1S24
(M99/R55-83) 24 83 0.1481 98.96 0.540 13.7 0.298 0.443 12350 5602
OPGW(LAL_Tube)-1S24
(M108/R94-83) 24 83 0.1622 108.39 0.559 14.2 0.393 0.585 21147 9592
OPGW(LAL_Tube)-1S24
(M108/R60-101) 24 101 0.1622 108.39 0.559 14.2 0.323 0.481 13565 6153
OPGW(LAL_Tube)-1S36
(M116/R96-98) 36 98 0.1741 116.36 0.595 15.1 0.417 0.621 21619 9806
OPGW(LAL_Tube)-1S36
(M116/R66-111) 36 111 0.1741 116.36 0.595 15.1 0.368 0.548 14758 6694
OPGW(LAL_Tube)-1S36
(M132/R112-124) 36 124 0.1978 132.14 0.626 15.9 0.478 0.712 25150 11408
OPGW(LAL_Tube)-1S36
(M132/R76-141) 36 141 0.1978 132.14 0.626 15.9 0.422 0.628 17119 7765
OPGW(LAL_Tube)-1S48
(M144/R113-153) 48 153 0.2148 143.52 0.646 16.4 0.499 0.742 25510 11571
OPGW(LAL_Tube)-1S48
(M147/R80-179) 48 179 0.2196 146.73 0.650 16.5 0.454 0.676 18087 8204
OPGW(LAL_Tube)-1S48
(M188/R156-253) 48 253 0.2814 188 0.725 18.4 0.673 1.001 35139 15939
OPGW(LAL_Tube)-1S48
(M188/R101-305) 48 305 0.2814 188 0.725 18.4 0.555 0.826 22699 10296
OPGW(LAL_Tube)-1S72

FIBER OPTIC CABLES


(M146/R114-159) 72 159 0.2178 145.55 0.677 17.2 0.504 0.75 25556 11592
OPGW(LAL_Tube)-1S72
(M146/R79-184) 72 184 0.2206 147.41 0.677 17.2 0.435 0.648 17727 8041
OPGW(LAL_Tube)-1S72
(M160/R132-188) 72 188 0.2394 160 0.701 17.8 0.569 0.846 29672 13459
OPGW(LAL_Tube)-1S72
(M160/R92-213) 72 213 0.2394 160 0.701 17.8 0.503 0.749 20585 9337

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 607
Copyright © 2018, American Wire Group, Inc. 20150407
OPGW Optical Ground Wire

Item # Fibers Fault Total Total Overall Overall Weight Weight RBS RBS
Current Conductor Conductor Diameter Diameter (lb/ft) (kg/km) (lb) (kb)
(KA2sec) Area Area (in) (mm)
(in2) (mm2)
ALUMINUM CLAD STEEL TUBE
OPGW(ALTube)-1S48
(M81/R76-44) 48 44 0.1218 81.39 0.469 11.9 0.316 0.47 17075 7745
OPGW(ALTube)-1S48
(M81/R48-55) 48 55 0.1218 81.39 0.469 11.9 0.259 0.385 10820 4908
OPGW(ALTube)-1S48
(M89/R75-55) 48 55 0.1330 88.87 0.488 12.4 0.327 0.487 16850 7643
OPGW(ALTube)-1S48
(M89/R51-66) 48 66 0.1330 88.87 0.488 12.4 0.280 0.416 11541 5235
OPGW(ALTube)-1S48
(M96/R82-64) 48 64 0.1430 95.56 0.504 12.8 0.351 0.522 18470 8378
OPGW(AL-Tube)-1S48
(M96/R56-76) 48 76 0.1430 95.56 0.504 12.8 0.299 0.445 12644 5735
OPGW(ALTube)-1S48
(M99/R93-66) 48 66 0.1481 98.99 0.512 13 0.378 0.562 20831 9449
OPGW(ALTube)-1S48
(M99/R63-76) 48 76 0.1481 98.99 0.512 13 0.331 0.493 14174 6429
OPGW(ALTube)-1S48
(M106/R98-76) 48 76 0.1586 106.01 0.528 13.4 0.403 0.599 22024 9990
OPGW(ALTube)-1S48
(M106/R63-94) 48 94 0.1586 106.01 0.528 13.4 0.330 0.491 14105 6398
FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
607 Information on this sheet subject to change without notice.
20150407 Copyright © 2018, American Wire Group, Inc.
OPGW Optical Ground Wire

Designation Fiber Diameter Fault RBS Weight Area Sag10


Count (in) Duty (lb) (lb/ft) (in2) Chart
(max) (kA2s)
MULTI STAINLESS STEEL TUBE
39AY68ACS-1C-1 12 0.528 74.8 19,468 0.365 0.16 1-1461
39AY68ACS-1C-2 12 0.528 71.9 20,620 0.380 0.16 1-1457
27AY59ACS-1C 16 0.472 46.3 16,536 0.305 0.13 1-1457
32AY54ACS-1C 16 0.472 48.1 15,613 0.293 0.13 1-1461
64AY37ACS-1C 20 0.512 75.1 13,987 0.286 0.15 1-1455
34AY73ACS-1C 24 0.528 68.9 21,771 0.395 0.16 1-1427
34AY74ACS-1C 24 0.531 74.1 20,928 0.386 0.16 1-1457
68AY42ACS-1C 24 0.534 88.0 15,529 0.316 0.16 1-1170
31AY87ACS-1C 24 0.555 84.5 24,105 0.438 0.17 1-1427
39AY68ACS-1C-3 24 0.528 71.9 20,620 0.380 0.16 1-1457
44AY75ACS-1C 24 0.555 91.7 21,555 0.404 0.17 1-1461
75AY44ACS-1C 24 0.555 103.9 16,455 0.337 0.17 1-1455
59AY66ACS-1C 24 0.571 109.8 20,098 0.391 0.18 1-536
79AY46ACS-1C 24 0.571 116.2 17,402 0.356 0.18 1-1455
27AY59ACS-2C 32 0.472 41.9 15,310 0.293 0.12 1-1450
59AY27ACS-2C 32 0.472 49.4 10,692 0.232 0.12 1-1439
86ACS-2C 32 0.472 28.8 20,851 0.366 0.12 1-1140
40AY100ACS-1C 36 0.602 118.0 26,909 0.502 0.20 1-1453
56AY83ACS-1C 36 0.602 123.1 25,716 0.479 0.20 1-1450
103AY40ACS-1C 36 0.606 153.9 17,073 0.368 0.21 1-1441
101AY59ACS-1C 36 0.646 190.1 21,902 0.454 0.24 1-1455
84AY76ACS-1C 36 0.646 179.7 25,249 0.499 0.24 1-536
27AY59ACS-3C 48 0.472 37.7 14,083 0.281 0.11 1-1461
32AY54ACS-3C 48 0.472 39.2 13,159 0.269 0.11 1-1444
39AY68ACS-1C-4 48 0.528 71.9 20,620 0.380 0.16 1-1457
59AY27ACS-3C 48 0.472 43.3 10,389 0.232 0.11 1-1439
67AY32ACS-2C 48 0.506 62.9 12,292 0.267 0.13 1-1439
34AY73ACS-2C 48 0.528 65.1 19,090 0.365 0.15 1-1450
34AY74ACS-2C 48 0.531 67.0 19,376 0.370 0.15 1-1450
49AY85ACS-2C 48 0.591 106.4 22,478 0.435 0.19 1-1461
67AY32ACS-3C 72 0.506 54.4 11,915 0.267 0.13 1-1455
40AY100ACS-2C 72 0.602 104.9 24,642 0.476 0.19 1-1457
101AY47ACS-2C 72 0.620 146.6 18,418 0.397 0.21 1-1439
101AY59ACS-2C 72 0.646 167.8 21,336 0.451 0.22 1-1170
110AY51ACS-2C 72 0.646 172.4 19,662 0.428 0.22 1-1439
59AY101ACS(27)-2C 72 0.646 155.9 24,617 0.517 0.22 1-1427
191AY45ACS-3C 72 0.785 426.6 19,735 0.504 0.34 1-1056
194AY74ACS-3C 144 0.836 498.6 23,121 0.599 0.37 1-1056

FIBER OPTIC CABLES


Notes:
*Many other designs are also available.
*Specifications are subject to change without notice.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 607
Copyright © 2018, American Wire Group, Inc. 20150407
Notes
FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Installation Manual for OPGW Cable

This handbook is formulated on IEEE 1138-2008 and IEEE 524-1992 etc.


OPGW has two functions: electric aerial ground wire and fiber communication.
It is constituted of AS wire, AA wire and stainless steel tube op-unit. The installation rules of OPGW
are almost the same as the engineering and installation modes of traditional aerial electric power
wire, referring to electric power company's aerial transmit circuitry installation skills, management
and other related files. In order to guarantee the installation of OPGW and avoid the waste of per-
sonnel and material resources, we compile this handbook as the reference, not instead of any other
manufacturers' installation instructions.
OPGW is usually installed on the top of pole of the electric power aerial wire. The following disad-
vantages should be considered: vibration caused by wind, hurricane, ice thickness, unsteady opera-
tion caused by temperature, and possible thunder attack, short circuit ere. Therefore, detailed
engineering program should be formulated according to different structures of OPGW and specific
route conditions. According to design requirement, OPGW should be allotted correctly; every tray of
optical fiber cable should he installed in the appointed part of route and should be laid according to
engineering chart operation file.
Please click HERE to download the complete intallation manual.

FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 608
Copyright © 2018, American Wire Group, Inc. 20150407
NOTES
FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
OPGW Cable & System Information Guide
for Hardware Selection

The following outline describes the OPGW cable information required to select proper cable attach-
ment hardware and accessories. Most of the cable information can be found in the cable specifica-
tion — it is recommended that this information be gathered along with the information about the
cable system. Submit this information to American Wire Group to verify proper application.
A. CABLE INFORMATION REQUIRED for DEAD-ENDS AND SUSPENSIONS
1. CABLE SPECIFICATIONS/Cable Specification Sheet Data
a. Cable Diameter: Overall outer diameter of the OPGW.
b. Cable Construction Strand Configuration: Lay Direction of outer wire strands, Distribution
and Location of individual strand materials in a cross-section, Number of strand layers.
c. Rated Breaking Strength
d. Fault Current
2. CABLE SYSTEM
a. Maximum Vertical Load at Hardware Attachment
b. Line Angles

In addition to the outline above, other products offered for OPGW applications require further infor-
mation as listed in Part B below.
B. ADDITIONAL INFORMATION FOR OTHER HARDWARE ACCESSORIES
1. Splice Closures, Closures, and Domes
a. Fiber Count
b. Fiber Type
c. Fiber Optic Element Configuration
d. Type of Buffer Tubes (plastic or stainless steel)
e. Core construction (Solid, Aluminum Tube, Aluminum Channel),
2. Spiral Vibration Damper
a. Span Lengths
b. Final Tension at the Average Annual Minimum Temperature (AAMT)
c. Terrain
3. FITTINGS (Y-Clevis, Clevis Eye, Yoke Plates), Ground Wire, Downlead Cushions, Cable Storage
a. Interface at structure
b. Type of Structure (Wood Pole, Concrete, Steel, Lattice Tower)
c. Ground Wire Material, Bonding Material
HARDWARE TESTS
The IEEE 1138 Test Standard for OPGW includes a series of tests that require suitable hardware to
demonstrate system performance. System tests include Tensile Strength, Vibration Test, and Gallop-
ing Tests among others. System tests require dead-ends and suspensions that can survive the test
parameters and prove cable/hardware compatibility.

FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 602
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
ADSS
All Dielectric Self-Supporting
Fiber Optic Cable

Applications
The “All Dielectric Self-Supporting (ADSS)” cables are designed for aerial self-supporting applica-
tions at short, medium and long span distances. ADSS cables offer a rapid and economical means
for deploying optical fiber cables along existing aerial rights-of-way. They are being deployed by
cable television operators, telephone companies, municipalities and emerging network operators,
in addition to electric power utilities.
Construction
The ADSS cable consists of a number of tubes/elements according to the specified number of
fibers. The elements are usually fiber-containing tubes; however fillers may be used to preserve the
cable geometry. Two to twelve color-coded fibers are loosely laid in each tube which is filled with a
water-blocking gel. The tubes are stranded around a dielectric central strength member and bound
in a jacket. A water-swelling tape is helically wrapped around the cable core. Aramid yarn strength
members are helically laid to supply peripheral strengthening of the cable. The outer jacket is tightly
bound over the aramid yarn layer. For long span applications a double jacket design can be consid-
ered. A ripcord is located under each jacket layer to facilitate its removal. For up to 30 fiber cables,
the “ADSB” design is applicable, for 32-144 fibers the “ADSC” design is applicable. Dry cable de-
signs, ballistic protection and other cable designs are available upon request..
Standards
• Cables are designed for aerial installation according to IEEE-P1 222
• Cables tested according to TIA/EIA-455 and IEC-60794-1.
• Cables meet or exceed Telcordia (Bellcore) requirements for outside plant cables (GR-20) when the
appropriate options are chosen.
Default Jacket Colors
PE HFFR SM Fibers Black Yellow MM Fibers Black Orange
Other jacket colors may be available, please specify.
Sag Chart
Below are the coefficients for a standard ADSS cable containing 32 to 60 fibers in 5 tubes with a sin-
gle outer jacket. The cable can be used in a span of 450 feet with NESC light conditions, 300 feet for
NESC medium and 240 feet for NESC heavy conditions.
• Cross section area 0.196 in^2
• Outside diameter 0.5 in
• Unit weight 0.081 lbs/ft
• Ultimate tension 5800 lbs
The following values are calculated at 68°F
• Final modulus of elasticity 3248850 psi
• Thermal expansion coefficient -2.78e-7°F
• Stress strain A1 2973280 psi
• Creep A1 2625190 psi

Item # ADS Number of Cable Cable Installation Span Sag in Tension Sag in Tension Sag in Tension
Series Elements Weight Diameter Tension (m) Light in Light Medium in Medium Heavy in Heavy
(kg/km) (mm) (N)(2) (m) (m) (N) (m) (N) (m) (N)
ADSS-1 2-30 ADSB 5 105 11.5 400 30 0.16 1230 0.48 1600 0.66 2370
ADSS-2 2-30 ADSB 5 105 11.5 525 40 0.22 1540 0.69 1970 0.95 2940
ADSS-3 2-30 ADSB 5 105 11.5 800 60 0.37 2100 1.16 2650 1.6 3900

FIBER OPTIC CABLES


ADSS-4 2-30 ADSB 5 105 11.5 860 70 0.46 2300 1.42 2930 2.27 4320
ADSS-5 2-30 ADSB 5 105 11.5 985 80 0.54 2560 1.68 3240 2.33 4755
ADSS-6 2-30 ADSB 5 105 11.5 1255 100 0.71 3040 2.25 3820 — —
ADSS-7 2-30 ADSB 5 105 11.5 1520 120 0.89 3500 2.80 4380 — —
ADSS-8 2-30 ADSB 5 105 11.5 1785 135 1.01 3870 3.23 4810 — —
ADSS-9 2-30 ADSB 5 105 11.5 1920 150 1.16 4170 3.70 5180 — —
ADSS-10 32-60 ADSC 5 120 12.7 425 30 0.16 1310 0.49 1650 0.67 2430
ADSS-11 32-60 ADSC 5 120 12.7 570 40 0.23 1630 0.71 2030 0.96 3000

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 603
Copyright © 2018, American Wire Group, Inc. 20140110
ADSS
All Dielectric Self-Supporting
Fiber Optic Cable

Item # ADS Number of Cable Cable Installation Span Sag in Tension Sag in Tension Sag in Tension
Series Elements Weight Diameter Tension (m) Light in Light Medium in Medium Heavy in Heavy
(kg/km) (mm) (N)(2) (m) (m) (N) (m) (N) (m) (N)
ADSS-12 32-60 ADSC 5 120 12.7 715 50 0.30 1940 0.94 2400 1.28 3530
ADSS-13 32-60 ADSC 5 120 12.7 845 60 0.38 2220 1.17 2750 1.62 4020
ADSS-14 32-60 ADSC 5 120 12.7 990 70 0.45 2520 1.43 3080 1.97 4500
ADSS-15 32-60 ADSC 5 120 12.7 1120 80 0.54 2780 1.69 3390 2.35 4990
ADSS-16 32-60 ADSC 5 120 12.7 1500 100 0.70 3340 2.22 4050 — —
ADSS-17 32-60 ADSC 5 120 12.7 1780 120 0.88 3840 2.79 4628 — —
ADSS-18 32-60 ADSC 5 120 12.7 1936 135 1.02 4150 3.26 5020 — —
ADSS-19 32-60 ADSC 5 120 12.7 2200 150 1.16 4530 — — — —
ADSS-20 62-72 ADSC 6 125 12.7 443 30 0.16 1320 0.50 1640 0.67 2500
ADSS-21 62-72 ADSC 6 125 12.7 580 40 0.24 1640 0.71 2040 0.97 3000
ADSS-22 62-72 ADSC 6 125 12.7 795 50 0.30 2000 0.92 2470 1.26 3590
ADSS-23 62-72 ADSC 6 125 12.7 950 60 0.38 2300 1.16 2800 1.60 4080
ADSS-24 62-72 ADSC 6 125 12.7 1085 70 0.46 2570 1.42 3130 1.96 4540
ADSS-25 62-72 ADSC 6 125 12.7 1240 80 0.54 2850 1.68 3450 2.32 5000
ADSS-26 62-72 ADSC 6 125 12.7 1530 100 0.72 3350 2.22 4070 — —
ADSS-27 62-72 ADSC 6 125 12.7 180 120 0.90 3830 2.80 4650 — —
ADSS-28 62-72 ADSC 6 125 12.7 2080 135 1.04 4220 3.23 5100 — —
ADSS-29 62-72 ADSC 6 125 12.7 2340 150 1.18 4600 — — — —
ADSS-30 74-96 ADSC 8 180 14.2 580 30 0.17 1500 0.5 1800 0.67 2590
ADSS-31 74-96 ADSC 8 180 14.2 820 40 0.24 1890 0.7 2260 0.96 3220
ADSS-32 74-96 ADSC 8 180 14.2 1000 50 0.32 2220 0.94 2630 1.28 3770
ADSS-33 74-96 ADSC 8 180 14.2 1220 60 0.4 2600 1.17 3060 1.61 4330
ADSS-34 74-96 ADSC 8 180 14.2 1400 70 0.49 2890 1.42 3415 1.97 4820
ADSS-35 74-96 ADSC 8 180 14.2 1640 80 0.57 3240 1.67 3800 — —
ADSS-36 74-96 ADSC 8 180 14.2 1960 100 0.76 3790 2.23 4450 — —
ADSS-37 74-96 ADSC 8 180 14.2 2360 120 0.94 4390 — — — —
ADSS-38 74-96 ADSC 8 180 14.2 2640 135 1.09 4800 — — — —
ADSS-39 98-126 ADSC 10 220 16 834 30 0.19 1730 0.49 2015 0.66 2810
ADSS-40 98-126 ADSC 10 220 16 1100 40 0.27 2150 0.70 2500 0.94 3500
ADSS-41 98-126 ADSC 10 220 16 1290 50 0.35 2500 0.93 2920 1.27 4070
ADSS-42 98-126 ADSC 10 220 16 1590 60 0.44 2910 1.17 3360 1.61 4660
ADSS-43 98-126 ADSC 10 220 16 1860 70 0.53 3290 1.40 3800 1.94 5220
ADSS-44 98-126 ADSC 10 220 16 2150 80 0.62 3680 1.66 4215 — —
ADSS-45 98-126 ADSC 10 220 16 2690 100 0.81 4400 2.17 5030 — —
ADSS-46 98-126 ADSC 10 220 16 3250 120 1.00 5114 — — — —
ADSS-47 122-144 ADSC 12 280 17.2 1030 30 0.21 1910 0.49 2200 0.66 3030
ADSS-48 122-144 ADSC 12 280 17.2 1340 40 0.29 2380 0.71 2710 0.95 3720
ADSS-49 122-144 ADSC 12 280 17.2 1720 50 0.37 2900 0.91 3280 1.25 4400
ADSS-50 122-144 ADSC 12 280 17.2 2030 60 0.47 3300 1.15 3740 1.58 5030
FIBER OPTIC CABLES

ADSS-51 122-144 ADSC 12 280 17.2 2440 70 0.56 3800 1.38 4270 — —
ADSS-52 122-144 ADSC 12 280 17.2 2750 80 0.65 4215 1.62 4725 — —
ADSS-53 122-144 ADSC 12 280 17.2 3470 100 0.85 5070 — — — —

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
603 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Loose Tube Fiber Optic Cable

Applications
Multi-purpose Outdoor — Aerial Lashed, Duct, Direct Buried
Constructions
Dielectric, Armored, Double Armored
Fiber Count
2 to 432 fibers in Color-coded Buffer Tubes
Fiber Types
Singlemode / Multimode
Options
Gel-Filled Core / Steel Central Member / Copper Pair(s)
Other versions
Central / Heavy Duty / Indoor-Outdoor
Performance
ANSI/ICEA, IEC, RUS, Telcordia GR-20
Mechanical Specifications
Installation
[+] Maximum installation load 600 lbf (2670 N)
[+] Maximum operation load 180 lbf (800 N)
Temperature Range
[+] Shipping and Storage -40°F to +167°F (-40°C to +75°C)
[+] Installation -22°F to +140°F (-30°C to +60°C)
[+] Operation -40°F to +158°F (-40°C to +70°C)

Item # Fiber Number of Diameter Diameter Approximate Approximate Bend Bend Bend Bend
Count Buffer (in) (mm) Cable Cable Radius Radius Radius Radius
Tubes Weight Weight Load Load No Load No Load
/MFT /km (in) (cm) (in) (cm)
(lb) (kg)
Dielectric (Non-Armored)
LT-DNA-1 2 to 60 5 0.42 10.6 53 79 8 21 4 11
LT-DNA-2 62 to 72 6 0.45 11.5 63 94 9 23 5 11
LT-DNA-3 74 to 84 7 0.49 12.3 72 107 10 25 5 12
LT-DNA-4 86 to 96 8 0.53 13.4 82 122 11 27 5 13
LT-DNA-5 98 to 108 9 0.56 14.2 90 134 11 28 6 14
LT-DNA-6 110 to 120 10 0.60 15.1 99 147 12 30 6 15
LT-DNA-7 122 to 132 11 0.63 16.1 109 162 13 32 6 16
LT-DNA-8 134 to 216 18 0.67 16.9 126 187 13 34 7 17
LT-DNA-9 218 to 264 22 0.74 18.9 153 228 15 38 7 19
LT-DNA-10 266 to 288 24 0.77 19.6 167 248 15 39 8 20
LT-DNA-11 290 to 432* 18 0.73 18.6 153 228 15 37 7 19
*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups.

FIBER OPTIC CABLES


Rated buffer storage length is 8 feet (2.4 meters)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 604
Copyright © 2018, American Wire Group, Inc. 20140110
Loose Tube Fiber Optic Cable

Item # Fiber Number of Diameter Diameter Approximate Approximate Bend Bend Bend Bend
Count Buffer (in) (mm) Cable Cable Radius Radius Radius Radius
Tubes Weight Weight Load Load No Load No Load
/MFT /km (in) (cm) (in) (cm)
(lb) (kg)
Single Jacket Armored
LT-SJA-1 2 to 60 5 0.48 12.2 98 146 10 24 7 18
LT-SJA-2 62 to 72 6 0.51 13.0 109 162 10 26 8 20
LT-SJA-3 74 to 84 7 0.55 14.0 122 182 11 28 8 21
LT-SJA-4 86 to 96 8 0.59 15.0 135 201 12 30 9 23
LT-SJA-5 98 to 108 9 0.62 15.8 146 218 12 32 9 24
LT-SJA-6 110 to 120 10 0.66 16.8 161 240 13 34 10 25
LT-SJA-7 122 to 132 11 0.69 17.6 171 255 14 35 10 26
LT-SJA-8 134 to 216 18 0.73 18.6 195 291 15 37 11 28
LT-SJA-9 218 to 264 22 0.81 20.6 231 344 16 41 12 31
LT-SJA-10 266 to 288 24 0.84 21.4 242 360 17 43 13 32
LT-SJA-11 290 to 432* 18 0.80 20.3 225 225 16 41 12 31
Double Jacket Armored
LT-DJA-1 2 to 60 5 0.54 13.8 118 175 11 28 8 21
LT-DJA-2 62 to 72 6 0.57 14.5 138 205 11 29 9 22
LT-DJA-3 74 to 84 7 0.61 15.5 153 228 12 31 9 23
LT-DJA-4 86 to 96 8 0.65 16.6 170 253 13 33 10 25
LT-DJA-5 98 to 108 9 0.68 17.3 182 272 14 35 10 26
LT-DJA-6 110 to 120 10 0.72 18.3 201 300 14 37 11 28
LT-DJA-7 122 to 132 11 0.75 19.1 212 315 15 38 11 29
LT-DJA-8 134 to 216 18 0.79 20.1 239 356 16 40 12 30
LT-DJA-9 218 to 264 22 0.87 22.1 283 421 17 44 13 33
LT-DJA-10 266 to 288 24 0.90 22.9 295 439 18 46 14 34
LT-DJA-11 290 to 432* 18 0.87 22.1 279 415 17 44 13 33
Dielectric Double Jacket (Non-Armored)
LT-DDJ-1 2 to 60 5 0.48 12.1 68 101 10 24 5 12
LT-DDJ-2 62 to 72 6 0.51 13.0 83 124 10 26 5 13
LT-DDJ-3 74 to 84 7 0.55 13.9 91 136 11 28 5 14
LT-DDJ-4 86 to 96 8 0.59 15.0 103 153 12 30 6 15
LT-DDJ-5 98 to 108 9 0.62 15.7 111 165 12 31 6 16
LT-DDJ-6 110 to 120 10 0.66 16.7 123 182 13 33 7 17
LT-DDJ-7 122 to 132 11 0.69 17.6 132 196 14 35 7 18
LT-DDJ-8 134 to 216 18 0.73 18.4 149 221 15 37 7 18
LT-DDJ-9 218 to 264 22 0.80 20.4 184 274 16 41 8 20
LT-DDJ-10 266 to 288 24 0.83 21.2 192 286 17 42 8 21
LT-DDJ-11 290 to 432* 18 0.79 20.1 182 271 16 41 8 20
*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups.
Rated buffer storage length is 8 feet (2.4 meters)
FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
604 Informatio on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Loose Tube Fiber Optic Cable

Item # Fiber Number of Diameter Diameter Approximate Approximate Bend Bend Bend Bend
Count Buffer (in) (mm) Cable Cable Radius Radius Radius Radius
Tubes Weight Weight Load Load No Load No Load
/MFT /km (in) (cm) (in) (cm)
(lb) (kg)
Double Jacket Double Armored
LT-DJDA-1 2 to 60 5 0.67 17.1 205 306 13 34 10 26
LT-DJDA-2 62 to 72 6 0.70 17.8 232 346 14 36 11 27
LT-DJDA-3 74 to 84 7 0.74 18.8 253 377 15 38 11 28
LT-DJDA-4 86 to 96 8 0.78 19.9 274 408 16 40 12 30
LT-DJDA-5 98 to 108 9 0.81 20.6 288 428 16 41 12 31
LT-DJDA-6 110 to 120 10 0.85 21.6 315 468 17 43 13 32
LT-DJDA-7 122 to 132 11 0.88 22.4 330 492 18 45 13 34
LT-DJDA-8 134 to 216 18 0.92 23.4 359 535 18 47 14 35
LT-DJDA-9 218 to 264 22 1.00 25.5 414 616 20 50 15 38
LT-DJDA-10 266 to 288 24 1.03 26.2 429 638 21 52 15 39
LT-DJDA-11 290 to 432* 18 1.01 25.7 416 619 20 51 15 38
Triple Jacket Double Armored
LT-TJDA-1 2 to 60 5 0.73 18.6 235 350 15 37 11 28
LT-TJDA-2 62 to 72 6 0.76 19.4 270 402 15 39 11 29
LT-TJDA-3 74 to 84 7 0.80 20.4 292 434 16 41 12 31
LT-TJDA-4 86 to 96 8 0.84 21.4 317 472 17 43 13 32
LT-TJDA-5 98 to 108 9 0.87 22.1 333 495 17 44 13 33
LT-TJDA-6 110 to 120 10 0.91 23.2 359 534 18 46 14 35
LT-TJDA-7 122 to 132 11 0.94 23.9 377 561 19 48 14 36
LT-TJDA-8 134 to 216 18 0.98 24.9 412 613 20 50 15 37
LT-TJDA-9 218 to 264 22 1.06 27.0 468 696 21 54 16 40
LT-TJDA-10 266 to 288 24 1.09 27.7 488 727 22 55 16 42
LT-TJDA-11 290 to 432* 18 1.08 27.4 486 723 22 55 16 42
*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups.
Rated buffer storage length is 8 feet (2.4 meters)

FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 604
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Loose Tube Fiber Optic Cable
for Direct Burial (Polyethylene Duct)

PBT Tube or PE filler Application


Single jacket loose tube cable with a dielectric central strength member, rein-
Optical fibers forced with glass yarns and polyethylene jacket, designed for outdoor applica-
tions, for direct installations in duct. The cable is supplied in UV resistant high
Central member
density polyethylene (HDPE) duct.
Central member jacket Construction
• Up to 12 optical fibers are enclosed in a polybutylene terephthalate (PBT)
Dielectric strength elements
tubes.
Outer PE jacket • Up to 24 tubes are stranded around jacketed dielectric central member to-
gether with PE fillers to form the cable core.
Water-blocking material • The fibers and tubes are color coded for easy identification.
• All the interstices in the cable core are filled with a water blocking materials to
prevent water penetration. Water swelling glass yarns are laid over the cable
Ripcord core to serve as peripheral dielectric strength members.
• A polyethylene jacket extruded over the glass yarns provides the final cable
shape and protection. A ripcord is provided under the jacket to facilitate its re-
moval.
• The cable is inserted into UV resistant high density polyethylene duct for wide
range of uses including extreme temperatures, abrasive and high tension ap-
plications in underground installations.
Cable Handling
Minimum bend radius with load 15 x OD
Minimum bend radius with no load 10 x OD
Minimum bend radius, storage coils 10 x OD
Maximum rated cable load (MRCL) 600 lbs (2700N)
Maximum long term load 180 lbs (800N)
Temperature Range
Installation -300°C to 600°C (-220°F to 1400°F)
Operation -600°C to 700°C (-760°F to 1580°F)
Storage -400°C to 750°C (-400°F to 1670°F)
Polyethylene Duct Characteristics
General specification:
The duct is manufactured from virgin high density polyethylene
The ducts are supplied with smooth walls and come either in orange color or in
black with 3 orange stripes
The duct is capable of being coiled in continuous lengths, transported, stored
outdoors and subsequently uncoiled for installation – without affecting its prop-
erties or performance
The duct performs in underground and above-ground installation an ambient
temperature range of minus 300°F to 1300°F
The duct specified for areal installations is ultraviolet light-resistant by UV light
stabilizer protecting the duct for a minimum of 12 months in direct sunlight
The duct is bent to a minimum (supported) radius of 10 outer diameters
Tests on finishing duct are performed in accordance with:
• ASTM D3035 Polyethylene Plastic Pipe Based on Controlled Outside Diameter
• ASTM D1248 Polyethylene Plastics Molding and Extrusion Materials (Type III,
Class A, B or C, Category 5, grade P34)
• ASTM D1693 Environmental Stress Cracking of Ethylene Plastics (Cond. B,

FIBER OPTIC CABLES


F20/96 HRS)
• ASTM D1238 Flow Rates of Thermoplastics by extrusion Plastometer
• ASTM D638 Tensile properties of Plastics
• ASTM D3350 Polyethylene Plastic Pipe and Fitting Materials (Cell #335440)
• NEMA TC 7 Smooth-wall Coilable Polyethylene Electrical Plastic Duct

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 606
Copyright © 2018, American Wire Group, Inc. 20150407
Loose Tube Fiber Optic Cable
for Direct Burial (Polyethylene Duct)

Cable Nominal Dimensions and Weight


FIBER COUNT 2-60 61-72 73-96 97-120 121-144 145-216 217-240 241-288
Cable Outer inch 0.4 0.42 0.49 0.56 0.62 0.61 0.64 0.71
Diameter mm 10.1 10.7 12.5 14.1 15.7 15.4 16.2 18
Cable lb/kft 47 53 69 97 112 97 109 134
Weight kg/km 70 79 103 145 166 145 162 200

Fiber Characteristics
Type Single Mode Multi Mode

μm
PHYSICAL CHARACTERISTICS 50/125 62.5/125

μm
Core Diameter 50.0 ± 2.5 50.0 ± 2.5

μm
Clad Diameter 125.0 ± 0.7 125.0 ± 1.0 125.0 ± 1.0
≤ 0.5,<0.2 typical ≤ 1.0 ≤ 1.0
μm
Core/Clad Concentricity Error (Offset)
Coating diameter 235-245 245 ± 10 245 ± 10
Tensile proof test kpsi 100 100 100
OPTICAL CHARACTERISTICS
Attenuation for Wavelength at 1310 nm dB/km ≤0.34 (max), ≤0.32 typical
Attenuation for Wavelength at 1550 nm dB/km ≤0.21 (max), ≤0.19 typical
Attenuation for Wavelength at 850 nm dB/km ≤ 2.3 ≤ 0.9
Attenuation for Wavelength at 1300 nm dB/km ≤ 0.6 ≤ 0.6
Zero Dispersion Wavelength (λ0) Nm 1302-1322 1295-1340 1320-1365

μm
MODE FIELD DIAMETER

μm
for wavelength 1310 nm 9.2 ± 0.4
for wavelength 1550 nm 10.4 ± 0.5
Cut-off wavelength (λcc) nm ≤ 1260

Fibers and Tubes Color-Code per TIA/EIA 598A


FIBER NO. 1 2 3 4 5 6 7 8 9 10 11 12
COLOR Blue Orange Green Brown Slate White Red Black Yellow Violet Rose Aqua
FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
606 Information on this sheet subject to change without notice.
20150407 Copyright © 2018, American Wire Group, Inc.
HDPE Conduit

Specifications
The material meets or exceeds the standards in ASTM D 3350-05 for Type III, Class PE 334480E (col-
ors with UV stabilizer) or Class C (black), high density polyethylene.

Property Test Method Value


Density (g/cm3) D792A or D1505 0.941 - 0.955
Melt Index (g/10 min) D1238 0.39 max.
Flexural Modulus (psi) D790 80,000 min.
Tensile Strength @ Yield (psi) D638 3,000 min.
ESCR, Condition B (10%, 50°C) D1693 F10 > 96 hours
Hydrostatic Design Basis (psi) D2387 NPR
* NPR - Not Pressure Rated

Ultraviolet Protection
Non-black conduit shall contain sufficient protection against UV radiation for a period not less than
one year. Black conduit contains sufficient protection against UV radiation in long term above
ground applications.
*Available with smooth or ribbed interior wall

Item # Nominal Nominal Minimum Nominal Min. Bend Max. Weight


Size Outside Wall Inner Radius Pulling /MFT
Diameter Thickness Diameter Unsupported Tension (lb)
(in) (in) (in) (in) (lb)
SDR 11
SDR11-13 13mm 0.625 0.055 0.500 8 210 46
SDR11-1/2 1/2" 0.840 0.076 0.668 10 390 85
SDR11-3/4 3/4" 1.050 0.095 0.840 12 605 130
SDR11-1 1" 1.315 0.120 1.055 14 950 204
SDR11-1-1/4 1 1/4" 1.660 0.151 1.338 18 1520 320
SDR11-1-1/2 1 1/2" 1.900 0.173 1.533 20 1760 416
SDR11-2 2" 2.375 0.216 1.917 26 3105 640
SDR11-3 3" 3.500 0.318 2.826 48 6740 1386
SDR11-4 4" 4.500 0.409 3.633 60 11145 2295
SDR 13.5
SDR13.5-1/2 1/2" 0.840 0.062 0.696 10 320 72
SDR13.5-3/4 3/4" 1.050 0.078 0.874 12 505 111
SDR13.5-1 1" 1.315 0.097 1.101 14 790 169
SDR13.5-1-1/4 1 1/4" 1.660 0.123 1.394 18 1260 265
SDR13.5-1-1/2 1 1/2" 1.900 0.141 1.598 20 1455 344
SDR13.5-2 2" 2.375 0.176 2.002 26 2580 532
SDR13.5-3 3" 3.500 0.259 2.951 48 5590 1154
SDR13.5-4 4" 4.500 0.333 3.794 60 9250 1905

FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 605
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
High Density Polyethylene Duct

Application
High Density Polyethelene Duct has been tested and proven under the most severe conditions.
From extreme temperatures to abrasive and high-tension applications in underground installations,
HDPE provides quality service and economy in a wide range of uses. As a smooth and flexible duct
for cable, HDPE is unequaled for ease of installation and continuous strength.
Description
The duct shall be manufactured from virgin high-density polyethylene. The addition of clean rework
material is permissible if generated in the manufacturer’s own plant. The ducts are supplied with ei-
ther smooth, ribbed, or corrugated walls and come in a multitude of colors. The duct shall be capa-
ble of being coiled (reeled) in continuous lengths, transported, stored outdoors and subsequently
uncoiled for installation - without affecting its properties or performance.
Environmental Performance
The duct shall perform in underground and aboveground temperature range of minus 300° temper-
ature range of minus 300°F to 1300°F without degradation of material properties. The duct specified
for aerial installation shall be ultraviolet light resistant. It shall be possible to bend the duct to a
minimum (supported) radius of 10 diameters. Workmanship The duct shall be free of visible cracks,
holes or other physical defects that would degrade its performance. It shall be as uniform as practi-
cable in respect to overall dimensions, color, density, thickness, etc.
Color
The duct for exposed areas (black) shall have a minimum of carbon black. All other colors shall have
a UV light stabilizer which will protect the duct for a minimum of 12 months in direct sunlight.
Markings
The duct shall have a durable identification showing the name or trademark of the manufacturer,
duct size (i.e., 2” IPS SCH-80), date and reference code. Duct for electrical cable should have “CAU-
TION - HIGH-VOLTAGE” printed at regular intervals. Other special markings can be agreed upon be-
tween the buyer and seller.
Capping
The open ends of each length of reeled duct shall be sealed by plastic caps to prevent the entrance
of dirt and/or moisture.
Pull Rope and Lubricant
The duct should be equipped with a factory installed rope or tape and pre-lubed to aid in the instal-
lation of cable. The rope can be provided with varying strengths as needed for a particular installa-
tion. Check with a manufacturer for specifications.
Couplings
Couplings should be available to quickly connect the duct and should be air and watertight (i.e.,
Duct-Lok type couplings in either plastic or aluminum, depending on type of installation).
Packaging
The duct should be provided on lightweight metal reels in maximum lengths possible with no joints
or splices. This will keep coupling requirements to a minimum. Special reel sizes and/ or dimen-
sions should be available for special installations.
Corrosion
The duct shall be resistant to most harsh chemicals and/or protected against degradation due to ox-
idation or general corrosion.
Installation
The duct shall be capable of being direct buried by plowing or trenching with no special considera-

FIBER OPTIC CABLES


tion to using selective backfill. The duct shall also be capable of being encased in concrete.
NOTE: HDPE conduit is manufactured to the dimension and requirements of ASTM F2160. Ovality
(out-of-roundness) and curvature are inherent characteristics of coiled, continuous length HDPE
conduit. While these conditions are normal and expected and are not a concern in most applica-
tions, some installations or applications may require “re-rounding” of the conduit. When this is nec-
essary, ovality should be corrected in the field by processing the conduit through re-rounding and
straightening equipment during installation.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 609
Copyright © 2018, American Wire Group, Inc. 201802011
High Density Polyethylene Duct

Tests on Resins and Finished Duct


Since specifications vary from customer to customer, we perform in-house lab tests on resins and finished products which include, but
are not limited to the following:
• ASTM D3035: Polyethylene Plastic Pipe Based on Controlled Outside Diameter.
• ASTM D2447: Polyethylene Plastic Pipe, Schedules 40
• ASTM D2239: Polyethylene Plastic Pipe Based on Controlled Inside Diameter.
• ASTM D1248: Polyethylene Plastics Molding and Extrusion Materials. (Type III, Class A, B,or C, Category 5, Grade P34).
• ASTM D1693: Environmental Stress-Cracking of Ethylene Plastics. (Cond. B, F20/96 HRS.)
• ASTM D1238: Flow Rates of Thermoplastics by Extrusion Plastometer.
• ASTM D1505: Density of Plastics by the Density Gradient Technique.
• ASTM D638: Tensile Properties of Plastics.
• ASTM D3350: Polyethylene Plastic Pipe and Fittings Materials. (Cell # 335440).
• NEMA TC 7: Smooth-Wall Coilable Polyethylene Electrical Plastic Duct. other ASTM tests i.e.: Tensile, Impact etc.
• ASTM D1505: Density of Plastics by the Density Gradient Technique.
• ASTM D638: Tensile Properties of Plastics.
• ASTM D2412: Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading.
• ASTM D2444: Determination of the Impact resistance of Thermoplastic Pipe and Fittings by Means of a Tup.
• ASTM D3485: Smooth-Wall Coilable Polyethylene Conduit for Pre-assembled Wire and Cable.
• ASTM F2160: Standard Specifications for Solid Wall High Density Polyethylene (HDPE) Conduit Based on Controlled Outside Diameter
(OD).
Design Considerations
Please refer to our technical data brochure. This shows different design parameters for polyethylene pipe (i.e., Wall Crushings, Wall Buck-
ling, etc.) as per the various SDR (wall thickness) ratings.
Special Options
Striped Duct - Three longitudinal stripes can be extruded on any standard size of smooth duct of any color. Stripes are approximately 1/8-
inch in width (varying slightly according to the duct size). There is no additional charge for Striped Duct.
Sequentially-Marked Duct - Duct can be ordered with numbering - every two feet - printed on the duct.
Cable in Conduit - Cable can be pre-installed in conduit utilizing the same stringent quality control as pre-roped and pre-taped duct. (Re-
quest the technical instruction guide for C.I.C. installation.)
Fire-Retardant HDPE - AWG offers Fire-Retardant (FR) in any type of duct (orange only). Fire Retardant HDPE has been successfully tested
and is offered in the top class, i.e., UL94 V-O only. Because the fire retardant process eliminates UV protection, Fire-Retardant duct must
be installed safe from exposure to UV light.

All sizes of duct are available with ProPullTM PreLube, ProPullTM Rope or Tape (1130#, 1250#, 1500# or 2500# tensile strength) and spool
lengths of your choice up to reel capacity.

Selected sizes available with UL Mark.


FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
609 Information on this sheet subject to change without notice.
20180201 Copyright © 2018, American Wire Group, Inc.
High Density Polyethylene Duct

TYPICAL THERMAL AND ELECTRICAL PROPERTIES OF HDPE DUCT

PROPERTY TEST METHOD UNITS VALUE


Vicat Softening Temp. ASTM D 1535 °F 255°
Heat Distortion Temp. ASTM D 648 °F 172°
Thermal Expansion ASTM D 696 in/in/°F 1 x 10-4
Thermal Conductivity ASTM C 177 BTU in/ft/hrs/°C 4.7
Volume Resistivity DIN 53482 Ω/cm >1016
Surface Resistance DIN 53482 Ω >1013
Dialectric Strength DIN 53481 KV/cm 700-850

TYPICAL PHYSICAL PROPERTIES: HIGH MOLECULAR WEIGHT HDPE PRODUCTS

PROPERTY ASTM (CONDITION) UNITS VALUE


Density (Black) D 1505 g/cm3 0.955
Melting Point DSC °F 261
Melt Index i2.16 D 1238 (E) gm/10 min. .11
Tensile Yield Strength D 638 psi 3300
Elongation at Break D 638 (Specimen I) % 800
Tens. of Modulus of Elast. D 638 psi 113.000
Flexural Modulus D 790 psi 136.000

← 103
Vicat Softening Temp. D 1525 °F 255
Brittleness Temp. D 746 °F
Heat Distortion Temp. D 648 °F 172
Thermal Expansion D 696 in/in/°F 1 x 10-4
Rockwell Hardness L D 795 — 49
Shore Hardness D D 2240 — 68

The data listed was determined on press molded test specimens, and may therefore deviate from specimens taken from pipes.

Classification
Type/Class/Cat./Grade D 1248 III/C/5/P34
Cell Classification D 3350 335440
Recommended Designation PE 34

Designated tests are made in accordance with current issues of ASTM Standard Testing Methods.

Copies of these methods are available, on request, from the America Society for Testing and Materials, 1916 Race Street, Philadelphia PA
19103

FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 609
Copyright © 2018, American Wire Group, Inc. 20180201
NOTES
FIBER OPTIC CABLES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
PORTABLE POWER CABLES
Table of Contents

SOOW/SEOOW Control Cable ..............................................................................................701


Welding Cable 600V ICEA Approved 105°C-40°C ................................................................702
Type W RHH/RHW Single Conductor 600/2000V.................................................................703
Type W Magnet Crane Cable Two Conductor 600/2000V....................................................704
Type W Round Multi-Conductor 600/2000V.........................................................................705
Type G Round 600/2000V......................................................................................................706
MP-GC Mine Power Feeder 5kV-15kV ...................................................................................707
SHD-GC Portable Power Cable 2kV-25kV .............................................................................708
Type DLO Diesel Locomotive Cable 2kV ..............................................................................709
Jumper Cable Transformer Lead Wire Non-Shielded 5kV/15kV .........................................710

POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 700
Copyright © 2018, American Wire Group, Inc. 20180201
NOTES
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
SOOW/SEOOW
Control Cables

Applications
Special uses requiring flexibility and mechanical toughness, high environmental resistance and
flame retardance. Push button remote controls. Motor control, stage equipment and lighting. Indus-
trial control and robotic systems. Outdoor applications. Suitable and approved for submersion in
water.

Construction
Flexible and tough jacket. Offers -50°C to 105°C temperature extremes. Offers excellent abrasion,
ozone, sunlight, chemical and oil resistance as well as water and mold resistant non-wicking light-
weight polypropylene fillers. Water resistant with high dielectric insulation. Lightweight, long last-
ing, easy to carry and easy to handle. All components are recyclable and non-hazardous for
environmental landfill disposal. Color coded conductors for easy identification.

Standards
Federal and Military use under Federal Spec. JC-580B. UL Listed SOOW/SEOOW 600V to NEC Arti-
cle 400, MSHA approval for flame resistance for mining applications.

Color Code
• 2/C Black, White
• 3/C Black, White, Green
• 4/C Black, White, Red, Green
• 5/C Black, White, Red, Green, Orange
** Ampacity based on NEC Table 400-5(A) for sized 18/2 thru 10/4 and table 400-5 (B) for sizes 8/2 thru 2/5.

Note
Sizes up to 10/4 are UL/CSA/MSHA, sizes 8/2 to 2/5 are non-UL constructions made with wall thick-
nesses in accordance with industry standards and MSHA approved.
The ampacity is provided for engineering information only. The manufacturer cannot recommend or
express the use of these ampacities since the exact application may need approval from the author-
ity having local jurisdiction. Above information is subject to engineering changes. Cold temperature
rating is -50°C.

Item # Size/ Strands Nominal Weight Ampacity


Conductors O.D. /MFT
(in) (lb)
22225 18/2 16/30 0.345 61 10
22325 18/3 16/30 0.365 71 10
22425 18/4 16/30 0.39 84 7
30505 18/5 16/30 0.465 113 5.6
22226 16/2 26/30 0.37 74 13
22326 16/3 26/30 0.39 87 13
22426 16/4 26/30 0.415 103 10
30506 16/5 26/30 0.495 140 8
22227 14/2 41/30 0.5 129 18
22327 14/3 41/30 0.525 151 18
22427 14/4 41/30 0.565 180 15
30507 14/5 41/30 0.645 232 12
22228 12/2 65/30 0.57 173 25
22328 12/3 65/30 0.595 203 25
22428 12/4 65/30 0.645 247 20
30508 12/5 65/30 0.71 301 16
22229 10/2 104/30 0.62 218 30
22329 10/3 104/30 0.655 265 30
22429 10/4 104/30 0.705 324 25
30509 10/5 104/30 0.765 387 20
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 701
Copyright © 2018, American Wire Group, Inc. 20140110
SOOW/SEOOW
Control Cables

Item # Size/ Strands Nominal Weight Ampacity


Conductors O.D. /MFT
(in) (lb)
22220 8/2 96/28 0.662 220 40
22320 8/3 96/28 0.701 290 40
22420 8/4 96/28 0.783 377 35
22470 8/5 96/28 0.851 452 28
22221 6/2 96/26 0.752 301 55
22321 6/3 96/26 0.818 421 45
22421 6/4 96/26 0.892 521 45
22521 6/5 96/26 0.992 665 36
22222 4/2 96/24 0.892 459 70
22322 4/3 96/24 0.913 585 70
22422 4/4 96/24 1.027 771 60
22552 4/5 96/24 1.117 1029 48
22223 2/2 7x17/.0223 1.091 665 95
22323 2/3 7x17/.0223 1.158 940 95
22423 2/4 7x17/.0223 1.267 1170 80
22553 2/5 7x17/.0223 1.396 1419 64
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
701 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Welding Cable
600V ICEA Approved
105°C - 40°C

Applications
Designed for connections from electrode holders and clamps to arc welders, bus welding box or
transformer.
Recommended for use in shipyards, mines, and other areas where cable is subject to extreme phys-
ical abuse. Flame retardant, oil resistant, resilient, resists compression cuts and abrasion, durable
handling.
This cable is not suitable for in line voltage use. Improper use could be hazardous to personnel and
could damage equipment.

Construction
• Conductor is annealed rope stranded bare copper conductor per ICEA S-75-381.
• Insulation is Ethylene Propylene Rubber (EPR) type EP, Class 45, 105 C. Table 50.55 of UL.1581.
• Operating Voltage: 600V max.
Standards
Meets ASTM B-3 ASTM B1732, ICEA S-175-381, IEC 254-1.

Available on Request
• Class M stranding
• Colors
• Hypalon or Neoprene Insulation
• UL or CSA Listed
• Custom Cut Lengths
Notes
• Nominal resistance of conductor acc to ICEA S-75-381 Class K
Welding Machine Rating
Lengths up to 13.7m Lengths 14m to 30.5m Lengths 76.2m to 30.8m
45ft 46ft to 100ft 101ft to 250ft
Amps AWG mm2 AWG mm2 AWG mm2
75 4 21 4 21 4 21
100 2 34 2 34 2 34
200 1 42 1 42 2/0 67
300 1/0 54 2/0 67 4/0 107
400 2/0 67 3/0 85 — —
600 3/0 85 4/0 107 — —

Item # Size Nominal Nominal Nominal Nominal Copper Weight Amps


AWG Stranding Resistance Thickness O.D. Content /MFT
Class K of Conductor of Insulation (in) /MFT (lb)
/MFT@25°C (in) (lb)
(ohm)
W01-6 6 285/30 0.4190 0.059 0.319 83 120 75
W02-4 4 412/30 0.2630 0.059 0.366 133 180 100
W03-2 2 647/30 0.1670 0.071 0.429 213 260 140
W04-1 1 817/30 0.1330 0.071 0.508 266 320 160
W05-1/0 1/0 1021/30 0.1050 0.079 0.555 342 400 190
W06-2/0 2/0 1289/30 0.0842 0.079 0.598 433 500 223
W07-3/0 3/0 1650/30 0.0668 0.079 0.673 538 610 265
W08-4/0 4/0 2065/30 0.0530 0.079 0.716 687 760 310
W09-250 250MCM 2479/30 N/A 0.125 0.866 804 855 445
W10-350 350MCM 3416/30 N/A 0.125 0.953 1120 1255 552
W11-500 500MCM 4921/30 N/A 0.125 1.130 1638 1800 695
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 702
Copyright © 2018, American Wire Group, Inc. 20180201
NOTES
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Type W
Type RHH/RHW Single Conductor
90°C UL 600/2000V

Applications
For use as portable power systems, entertainment industry activities such as theatre, television,
nightclubs, motion pictures, mobile communication vans, spotlights and sound permanent or tem-
porary power. Permanent wiring of 600 volt power supplies, hoists, cranes and other applications
where flexible power leads must be installed in conduit or raceways.

Construction
• Conductor is 8 — 500 MCM fully annealed stranded bare copper.
• Insulation is premium grade 90°C EPDM.
• Jacket is black CPE.
• Jacket marking is TYPE W PORTABLE POWER CABLE (UL) DRY 90°C WET 75°C 2000V SUNLIGHT
RESISTANT - P(#) MSHA-(SIZE)-TYPE RHH (UL) 600V.
• Temperature range of -40°C to +90°C .
• Voltage rating of 600 volt Type W.
• Water and sunlight resistant.
• Designed to withstand severe environmental conditions.
• Withstands exposure to oil, acids, alkalies, heat, flame, moisture and chemicals.
• Lengths cut to order.
Standards
• Meets or exceeds flame test requirements of MSHA, IEEE, ICEA, and UL
• Conforms to ICEA S-61-658
• ICEA S-75-381 NEMA WC70 UL TYPE W and RHH or RHW-2 MSHA approved

Item # Size Conductor Nominal Nominal Nominal Nominal Current Net


AWG Stranding Thickness of Thickness of O.D. O.D. Amps Weight
Insulation Insulation (in) (mm) /MFT
(in) (mm)
S-01-W8 8 133 0.06 1.52 0.450 11.93 83 140
S-02-W6 6 259 0.06 1.52 0.530 13.46 109 205
S-03-W4 4 133 0.06 1.52 0.585 14.86 145 275
S-04-W2 2 259 0.06 1.52 0.630 16.00 192 365
S-05-W1 1 259 0.08 2.03 0.745 18.92 223 475
S-06-W10 1/0 259 0.08 2.03 0.780 19.81 258 555
S-07-W20 2/0 259 0.08 2.03 0.845 21.46 298 675
S-08-W30 3/0 259 0.08 2.03 0.910 23.11 345 805
S-09-W40 4/0 259 0.08 2.03 0.970 24.64 400 965
S-10-W250 250 259 0.095 2.41 1.035 26.29 445 1165
S-11-W350 350 855 0.095 2.41 1.130 28.72 552 1520
S-12-W500 500 1235 0.095 2.41 1.300 33.02 695 2100

POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 703
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Type W
2-Conductor Magnet Crane Cable
600/2000V 90°C

Applications
Magnet Crane Cable is a heavy duty, portable cable that is designed especially to use on magnet
cranes, and may be used on mobile mining equipment, lifting magnets, cutters, loaders, conveyers,
drills or pumps where grounded circuits are not required, in portable power situations and as tem-
porary power supply.

Construction
• Conductors are flexible stranded, annealed copper.
• Insulation is Thermoset EPR.
• Cabled with fillers for roundness with an open reinforced over assembly for mechanical protec-
tion.
• Jacket is Thermoset CPE.
Standards
• Meets or exceeds flame test requirements of MSHA, IEEE, ICEA, and UL
• Conforms to ICEA S-61-658
• ICEA S-75-381 NEMA WC-70 UL TYPE W and RHH or RHW-2 MSHA approved

Item # No. of Size Number of Insulation Overall Net Weight


Conductors AWG Strands Thickness Diameter /MFT.
(mil) (in) (lb)
MC1W-8 2 8 133 .060 .81 Inches 430 Lbs
MC2W-6 2 6 259 .060 .93 Inches 590 Lbs
MC3W-4 2 4 259 .060 1.08 Inches 830 Lbs
MC4W-2 2 2 259 .060 1.27 Inches 970 Lbs

POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 704
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Type W Round
Multi-Conductor
90°C UL 600/2000V

Applications
For use in heavy duty services as power supply cable, AC systems (grounded and ungrounded),
mobile and portable electrical equipment, motor and battery leads. For 2 conductor cables use on
DC or AC single phase systems where no grounding is required, or on DC systems with one con-
ductor for grounding. For 4 conductor cables, use on two or three phase AC systems with one con-
ductor used for grounding. For 5 conductor cables, use in applications where separating the system
neutral from the frame ground is required.

Construction
• Conductor is 8 - 500 MCM fully annealed stranded bare copper.
• Insulation is premium grade color coded 90°C EPDM.
• Jacket is 90°C Black CPE+ with temperature range of -40°C to +90°C .
• Jacket is indent printed for easy identification (successive footage printing available).
• Jacket marking is TYPE W PORTABLE POWER CABLE 2000V 90°C DRY 75°C WET SUN RES (UL) -
PK(#) MSHA
• Designed to withstand severe environmental conditions.
• Withstands exposure to oil, acids, alkalies, heat, flame, moisture and chemicals.
• Rope lay stranding for maximum flex life with excellent impact resistance and cable core bound
for superior flexibility and toughness.
• Suitable for continuous submersion in water.
• Lengths cut to order.
Standards
ICEA S-75-381 NEMA WC-58 UL TYPE W and MSHA approved.
Notes
• These ampacities are based on a conductor temperature of 90°C and an ambient air temperature
of 40°C per ICEA PUB-S-75-381 NEMA WC0-8. For ampacities per National Electrical Code require-
ments, refer to the latest NEC edition.
• Shipping tolerance +/- 10%
• Heavy duty neoprene jacket optional.
• Successive footage printing available.

Item # No. of Size Conductor Nominal Nominal Nominal Nominal Current Net
Conductors AWG Stranding Thickness of Thickness of O.D. O.D. Ampacity Weight
Insulation Insulation (in) (mm) /MFT
(in) (mm) (lb)
M01-2W8 2 8 133 0.060 1.52 0.790 20.07 72 365
M02-2W6 2 6 259 0.060 1.52 0.910 23.11 95 510
M03-2W4 2 4 259 0.060 1.52 1.060 26.92 127 700
M04-2W2 2 2 259 0.060 1.52 1.250 31.75 167 1015
M05-2W1 2 1 259 0.080 2.03 1.440 36.58 191 1490
M06-2W10 2 1/0 259 0.080 2.03 1.520 38.81 217 1710
M07-2W20 2 2/0 259 0.080 2.03 1.650 41.92 250 1880
M08-2W30 2 3/0 259 0.080 2.03 1.770 44.96 386 2420
M09-2W40 2 4/0 259 0.080 2.03 1.920 48.77 328 2490
M10-3W8 3 8 133 0.060 1.52 0.955 24.26 59 530
M11-3W6 3 6 259 0.060 1.52 1.010 25.65 79 660
M12-3W4 3 4 259 0.060 1.52 1.150 29.21 104 925
M13-3W2 3 2 259 0.060 1.52 1.320 33.53 138 1325
M14-3W1 3 1 259 0.080 2.03 1.490 37.85 161 1600
M15-3W10 3 1/0 259 0.080 2.03 1.650 41.92 186 2280
M16-3W20 3 2/0 259 0.080 2.03 1.750 44.45 215 2680
M17-3W30 3 3/0 259 0.080 2.03 1.890 48.01 249 3220
M18-3W40 3 4/0 259 0.080 2.03 2.040 51.82 287 3900
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 705
Copyright © 2018, American Wire Group, Inc. 20140110
Type W Round
Multi-Conductor
90°C UL 600/2000V

Item # No. of Size Conductor Nominal Nominal Nominal Nominal Current Net
Conductors AWG Stranding Thickness of Thickness of O.D. O.D. Ampacity Weight
Insulation Insulation (in) (mm) /MFT
(in) (mm) (lb)
M19-3W250 3 250 327 0.095 2.41 2.390 60.71 320 5070
M20-3W350 3 350 855 0.095 2.41 2.680 68.07 394 6570
M21-3W500 3 500 1235 0.095 2.41 3.030 76.96 487 8700
M22-4W8 4 8 133 0.060 1.52 0.955 24.26 54 620
M23-4W6 4 6 259 0.060 1.52 1.090 27.69 72 825
M24-4W4 4 4 259 0.060 1.52 1.250 31.75 93 1175
M25-4W2 4 2 259 0.060 1.52 1.480 37.59 122 1650
M26-4W1 4 1 259 0.080 2.03 1.680 42.67 143 2450
M27-4W10 4 1/0 259 0.080 2.03 1.790 45.47 165 2570
M28-4W20 4 2/0 259 0.080 2.03 1.930 49.02 192 3450
M29-4W30 4 3/0 259 0.080 2.03 2.070 52.58 221 4050
M30-4W40 4 4/0 259 0.080 2.03 2.260 57.40 255 4970
M31-5W8 5 8 133 0.060 1.52 1.070 27.18 50 710
M32-5W6 5 6 259 0.060 1.52 1.210 30.73 68 1010
M33-5W4 5 4 259 0.060 1.52 1.400 35.56 88 1400
M34-5W2 5 2 259 0.060 1.52 1.610 40.89 116 2340
M35-5W1 5 1 259 0.080 2.03 1.880 47.75 136 3040
M36-5W10 5 1/0 259 0.080 2.03 1.960 49.78 157 3460
M37-5W20 5 2/0 259 0.080 2.03 2.130 54.10 182 4180
M38-5W30 5 3/0 259 0.080 2.03 2.260 57.40 210 4900
M39-5W40 5 4/0 259 0.080 2.03 2.460 62.48 242 5980
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
705 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Type G Round
90°C 600/2000V

Applications
For use in heavy duty services as power supply cable, mobile and portable electrical. For 2 conduc-
tor cables use with AC single phase systems where grounding is required.

Construction
• Conductor is 8 — 500 MCM fully annealed stranded bare copper.
• Insulation is premium grade color coded 90°C EPR.
• Withstands exposure to oil, acids, alkalies, heat, flame, moisture and chemicals.
• Rope lay stranding for maximum flex life with excellent impact resistance and cable core bound
for superior flexibillity and toughness.
• Suitable for continuous submersion in water.
• Jacket is 90°C Black CPE with temperature range of -40°C to +90°C .
• Jacket is Indent printed for easy identification (successive footage printing available).
• Jacket marking is (SIZE) TYPE G-GC portable power cable 600/200V 90°C sun oil resistant C(UL)
FT-5 (-40°C) MSHA.
• Lengths cut to order.
Standards
ICEA S-75-381 and MSHA approved.

Notes
• These ampacities are based on a conductor temperature of 90°C and an ambient air temperature
of 40 °C per ICEA PUB-S-75-381 NEMA WC70. For ampacities per National Electrical Code require-
ments, refer to the latest NEC edition.
• Shipping tolerance +/- 10%
• Heavy duty neoprene jacket optional.
• Succesive footage printing available.

Item # No. of Size Conductor Grounding Ground Nominal Nominal Nominal Nominal Current Net
Conductors AWG Stranding Conductor Check Thickness of Thickness of O.D. O.D. Ampacity Weight
Size Size Insulation Insulation (in) (mm) /MFT
AWG AWG (in) (mm) (lb)
2 Conductor
2-01-G8 2 8 133 2 # 10 0.06 1.52 0.81 20.57 72 495
2-02-G6 2 6 259 2 # 10 0.06 1.52 0.93 23.62 95 650
2-03-G4 2 4 259 2#8 0.06 1.52 1.08 27.43 127 940
2-04-G2 2 2 259 2#6 0.06 1.52 1.27 32.26 167 1360
2-05-G1 2 1 259 2#5 0.06 2.03 1.44 36.58 191 1730
2-07-G20 2 2/0 259 2#3 0.06 2.03 1.65 41.91 250 2240
2-08-G30 2 3/0 259 2#2 0.06 2.03 1.77 44.96 286 2860
2-09-G40 2 4/0 259 2#1 0.06 2.03 1.92 48.77 328 3500
2-6-0G10 2 1/0 259 2#4 0.06 2.03 1.52 38.61 217 2000

POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 706
Copyright © 2018, American Wire Group, Inc. 20140110
Type G Round
90°C 600/2000V

Item # No. of Size Conductor Grounding Ground Nominal Nominal Nominal Nominal Current Net
Conductors AWG Stranding Conductor Check Thickness of Thickness of O.D. O.D. Ampacity Weight
Size Size Insulation Insulation (in) (mm) /MFT
AWG AWG (in) (mm) (lb)
3 Conductor
3-01-G8 3 8 133 2 # 10 10 0.060 1.52 0.965 24.51 59 665
3-02-G6 3 6 259 2 # 10 10 0.060 1.52 1.050 26.67 79 830
3-03-G4 3 4 259 2#8 10 0.060 1.52 1.165 29.59 104 1145
3-04-G2 3 2 259 2#7 10 0.060 1.52 1.340 34.04 138 1485
3-05-G1 3 1 259 2#6 8 0.080 2.03 1.510 38.35 161 2100
3-06-G10 3 1/0 259 2#5 8 0.080 2.03 1.650 41.91 186 2550
3-07-G20 3 2/0 259 2#4 8 0.080 2.03 1.750 44.45 215 3020
3-08-G30 3 3/0 259 2#3 8 0.080 2.03 1.890 48.01 249 3660
3-09-G40 3 4/0 259 2#2 8 0.080 2.03 2.040 51.82 287 4410
3-10-G250 3 250 627 2#2 8 0.095 2.41 2.390 60.71 320 6060
3-11-G350 3 350 855 2 # 1/0 8 0.095 2.41 2.680 68.07 394 7400
3-12-G500 3 500 1235 2 # 2/0 8 0.095 2.41 3.030 76.96 487 10100
4 Conductor
4-01-G8 4 8 133 4 # 12 0.06 1.52 0.970 24.64 54 635
4-02-G6 4 6 259 4 # 12 0.06 1.52 1.110 28.19 72 900
4-03-G4 4 4 259 4 # 10 0.06 1.52 1.245 31.62 93 1280
4-04-G2 4 2 259 4#9 0.06 1.52 1.470 37.34 122 2000
4-05-G1 4 1 259 4#8 0.08 2.03 1.680 42.67 143 2660
4-06-G10 4 1/0 259 4#7 0.08 2.03 1.790 45.47 165 3140
4-07-G20 4 2/0 259 4#6 0.08 2.03 1.930 49.02 192 3780
4-08-G30 4 3/0 259 4#5 0.08 2.03 2.070 52.58 221 4500
4-09-G40 4 4/0 259 4#4 0.08 2.03 2.260 57.40 255 5520
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
706 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Type MP-GC
3-Conductor EPR or XLP 5kV-15kV
100% Insulation Level (Grounded) 90°C

Applications
This cable is designed for high voltage connections between power distribution systems in mines,
mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is
required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing
service.

Construction
• Conductor is stranded annealed copper enveloped in a strand shield.
• Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE).
• Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consist-
ing of two bare grounds and one 8-gauge insulated ground check that are cabled together in the
interstices of the power conductors and fillers are added to make round.
• A single faced rubber filled tape is applied overlapped.
• 5kV and 8kV jacket is Chlorinated Polyethylene (CPE).
• 15kV jacket is Polychloride (PVC); Jacket options include Chlorinated Polyethelene (CPE or Hy-
palon (SCSPE).
Standards
Conforms to ICEA S-75-381 NEMA WC70

Notes
Shipping tolerance +/- 10%

Item # Power Power Power Ground Ground Jacket Overall Net


Conductors Conductors Conductors Wire Wire Thickness Diameter Weight
Size Number of Insulation Size Number of (in) (in) /MFT
AWG Strands Thickness AWG Strands (lb)
(in)
5kV CPE
MP5-01-4 4 7 .090 7 7 1.32 .110 1240
MP5-02-2 2 7 .090 5 7 1.45 .110 1670
MP5-03-1/0 1/0 19 .090 3 7 1.63 .110 2300
MP5-04-2/0 2/0 19 .090 2 7 1.75 .140 2730
MP5-05-4/0 4/0 19 .090 1/0 19 2.00 .140 3490
MP5-06-250 250 37 .090 1/0 19 s 2.13 .140 4620
MP5-07-350 350 37 .090 2/0 19 2.35 .140 5940
MP5-08-500 500 37 .090 4/0 19 2.64 .170 8160
8kV CPE
MP8-01-4 4 7 0.115 8 7 0.11 1.43 1440
MP8-02-2 2 7 0.115 6 7 0.11 1.55 1760
MP8-03-1 1 19 0.115 5 7 0.11 1.65 2070
MP8-04-1/0 1/0 19 0.115 4 7 0.11 1.75 2440
MP8-05-2/0 2/0 19 0.115 3 7 0.14 1.88 2940
MP8-06-4/0 4/0 19 0.115 1/0 19 0.14 2.12 4130
MP8-07-250 250 37 0.115 2/0 19 0.14 2.25 4760
MP8-08-350 350 37 0.115 3/0 19 0.14 2.46 6090
MP8-09-500 500 37 0.115 4/0 19 0.14 2.75 8360
15kV PVC
MP15-01-2 2 7 0.175 6 7 0.19 1.88 2190
MP15-02-1/0 1/0 19 0.175 4 7 0.14 2.05 2890
MP15-03-2/0 2/0 19 0.175 3 7 0.14 2.15 3350
MP15-04-4/0 4/0 19 0.175 1 7 0.14 2.4 4610
MP15-05-250 250 37 0.175 1/0 19 0.14 2.5 4990
MP15-06-350 350 37 0.175 2/0 19 0.14 2.75 6380
MP15-01-500 500 37 0.175 4/0 19 0.14 3.1 8770
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 707
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
SHD-GC
3-Conductor EPR/CPE 2kV
100% Insulation Level – 90°C

Applications
This cable is designed for heavy duty high voltage portable power trailing cable between the load
center and equipment such as power shovels, draglines, and other excavators and is suitable for
use in open pit mines, quarries and on gantry cranes where the delivery of a heavy power load and
maximum safety is required.

Construction
• Conductor is extra flexible, stranded, tinned annealed copper.
• Insulation is Ethylene Propylene Rubber (EPR).
• Covered grounding and 8-gauge ground check conductors.
• Jacket is Black Chlorinated Polyethylene (CPE).
Standards
Conforms to ICEA S-75-381 NEMA WC70

Notes
• Neoprene jacket optional.
• Shipping tolerance +/- 10%

Item # Power Power Power Ground Ground Jacket Overall Net


Conductors Conductors Conductors Wire Wire Thickness Diameter Weight
Size Number of Insulation Size Number of (in) (in) /MFT
AWG Strands Thickness AWG Strands (lb)
(in)
2kV
DL01-5-6 6 133 .110 10 49 .185 1.56 1460
DL05-5-4 4 133 .110 8 133 .185 1.68 1690
DL03-5-5 2 259 .110 6 133 .205 1.87 2290
DL04-5-1/0 1/0 266 .110 4 133 .220 2.08 3110
DL05-5-5/0 2/0 342 .110 2 133 .220 2.20 3570
DL06-5-4/0 4/0 532 .110 1 259 .235 2.50 4990
DL07-5-550 250 427 .120 1/0 259 .250 2.69 5820
DL08-5-350 350 427 .120 2/0 259 .265 2.95 7540
DL09-5-500 500 427 .120 4/0 259 .280 3.31 9840

POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 708
Copyright © 2018, American Wire Group, Inc. 20140110
Type SHD-GC
3-Conductor EPR/CPE 2kV
100% Insulation Level – 90°C

Item # Power Power Power Ground Ground Jacket Overall Net


Conductors Conductors Conductors Wire Wire Thickness Diameter Weight
Size Number of Insulation Size Number of (in) (in) /MFT
AWG Strands Thickness AWG Strands (lb)
(in)
5kV
DL01-2-6 6 133 .070 10 19 .155 960
DL02-2-4 4 133 .070 8 133 .155 1410
DL03-2-2 2 259 .070 6 133 .170 1940
DL04-2-1/0 1/0 266 .080 4 133 .190 2950
DL05-2-2/0 2/0 342 .080 2 133 .250 3470
DL06-2-4/0 4/0 532 .080 1 133 .220 4800
DL07-2-250 250 427 .095 1/0 133 .220 5950
DL08-2-350 350 427 .095 2/0 133 .235 7400
DL09-2-500 500 427 .095 4/0 259 .265 10100
8kV
DL01-8-4 4 133 150 8 49 .205 1.94 2240
DL02-8-2 2 133 150 6 133 .220 2.12 2730
DL03-8-1/0 1/0 259 150 4 133 .220 2.32 3380
DL04-8-2/0 2/0 259 150 3 133 .235 2.46 4030
DL05-8-4/0 4/0 259 150 1 133 .250 2.75 5440
DL06-8-250 250 427 150 1/0 259 .250 2.89 6280
DL07-8-350 350 427 150 2/0 259 .280 3.20 8300
DL01-8-500 500 427 150 4/0 250 .295 3.56 12000
15kV
DL01-15-2 2 133 210 6 133 .235 2.41 2950
DL02-15-1/0 1/0 259 210 4 133 .250 2.64 3650
DL03-15-2/0 2/0 259 210 3 133 .250 2.73 4250
DL04-15-4/0 4/0 259 210 1 259 .265 3.05 5930
25kV
DL02-25-2/0 1/0 259 295 4 133 .265 3.05 5250
DL03-25-4/0 2/0 259 295 3 133 .280 3.20 6000
DL04-25-250 4/0 259 295 1 259 .295 3.50 7710
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
708 Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Type DLO
Diesel Locomotive Cable
600/2000V 90°C

Applications
This cable is for wiring down tower applications and may be used on electrically driven, earth mov-
ing equipment, as power supply to A.C. welding equipment, as water heater leads, and in motor
and power lead applications. May be installed in wet or dry areas, conduit, ducts, trays or troughs.

Construction
• Conductor is extra flexible tinned, stranded copper with a separator layer.
• EPR insulation.
• Jacket is CPE (Hypalon jacket available upon request).
Standards
• Meets flame test requirements of MSHA and passes ICEA cold bend test at -40°C.
• Meets AAR specifications.
• UL listed as RHH-RHW-2.
• Rated for CT use, 1/0 and larger.
Notes
• Ampacity based on single conductor in free air, 90°C conductor temperature, 40°C ambient per
ICEAS-75-381.
• Sequential footage marks.
• Shipping tolerance +/- 10%

Item # Area Size Number of Insulation Jacket Overall Net Weight Ampacity
Circular AWG Strands in Thickness Thickness Diameter /MFT 1/C Free Air
(mil) Conductor (in) (mil) (in) (lb) 90°C
DL-600/2-1 3831 14 19 .045 30 .24 34 32
DL-600/2-2 6088 12 19 .045 30 .25 45 36
DL-600/2-3 10910 10 27 .045 30 .29 68 55
DL-600/2-4 14950 8 37 .060 30 .33 82 83
DL-600/2-5 24640 6 61 .060 30 .40 125 109
DL-600/2-6 36760 5 91 .060 30 .43 175 127
DL-600/2-7 42420 4 105 .060 30 .45 195 145
DL-600/2-8 60600 2 150 .060 30 .50 265 192
DL-600/2-9 90900 1 225 .080 45 .64 425 223
DL-600/2-10 111100 1/0 275 .080 45 .69 500 258
DL-600/2-11 131300 2/0 325 .080 45 .73 570 298
DL-600/2-12 181800 3/0 450 .080 45 .80 780 345
DL-600/2-13 222200 4/0 550 .080 45 .86 890 400
DL-600/2-14 262600 262.6 650 .090 65 .97 1100 458
DL-600/2-15 313100 313.1 775 .090 65 1.01 1280 514
DL-600/2-16 373700 373.7 925 .090 65 1.11 1500 574
DL-600/2-17 444400 444.4 1100 .090 65 1.18 1760 642
DL-600/2-18 535300 535.3 1325 .110 65 1.29 2110 725
DL-600/2-19 646400 646.4 1591 .110 65 1.38 2410 815
DL-600/2-20 777700 777.7 1924 .110 65 1.47 2930 910
DL-600/2-21 929200 929.2 2299 .110 65 1.58 3450 1025
DL-600/2-22 1111000 1111.0 2745 .110 65 1.74 4130 1143
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 709
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Jumper Cable
Transformer Lead Wire
Non-Shielded 5kV/15kV 90°C

Applications
This cable is for use as flexible power leads permitting temporary connections or bypassing ener-
gized power lines at voltages up through 15kV, phase to phase.

Installation
These cables must be positioned away from contact with grounds, transformer cases, cross-arms,
etc. to avoid possible high stress and capacitance leakage due to the fact that jumper cables cannot
be protected against prolonged contact with other conductors or grounds by shielding.

Construction
• Conductor is flexible stranded copper conductor with a semi-conducting strand shield covering.
• Insulation is Ethylene Propylene Rubber (EPR).
• Jacket is heavy duty, red NBR/PVC jacket.
• Rating is 5KV/15KV, 90°C.
• Non-Shielded
Standards
• ICEA S-75-381 NEMA WC70

Item # Size Number of Overall Diameter Net Weight


AWG Strands (in) /MFT
(lb)
J1-5/15-2 2 259 0.900 550
J2-5/15-10 1/0 259 0.985 730
J3-5/15-20 2/0 259 1.040 850
J4-5/15-40 4/0 516 1.165 1174
J5-5/15-350 350 855 1.416 2220
J6-5/15-500 500 1235 1.580 2377

POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
Information on this sheet subject to change without notice. 710
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES
POWER CABLES
PORTABLE

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
sales@buyawg.com
APPENDIX
Table of Contents

Terms & Conditions/Warranty ..................................................................................................A


Wire & Cable: Handling and Installation Engineering Guide ................................................H
Jacket Material Selection Chart................................................................................................K
Insulation Performance Specifications: EPR & TRXLPE .........................................................O
Allowable Ampacities of Insulated Conductors .....................................................................N
Thermal Resistivity of Materials .............................................................................................M
PowerGuard® Testing Recommendations............................................................................321
Wire & Cable: Methods of Color Coding & Color Coding Charts ..........................................B
Recommended Reel Handling Practices..................................................................................C
Steel Reel Specifications & General Purpose Steel Fluted Returnable Reels ......................D
Cabling.........................................................................................................................................I
Metric Size to AWG Size............................................................................................................E
Copper Conductor Stranding Chart: Class A thru M ..............................................................G
Wire & Cable: Glossary of Terms ..............................................................................................F

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. 000
Copyright © 2018, American Wire Group, Inc. 20170306
NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Terms & Conditions
Warranty

Price Warranty
Prices are based on COMEX copper or LME aluminum listed on the All merchandise ordered will be supplied in accordance with the
quotation. Prices are subject to copper/aluminum adjustment at the description on the face of the order acknowledgment and in accor-
time of shipment in the event that COMEX or LME copper exceeds dance with applicable specifications and design standards, and will
the quoted base in excess of 10%. be substantially free from defects in material and workmanship.
The Seller’s liability in respect to any defect in or failure of the mer-
Cancellation chandise supplied, as well as any loss, injury or damage attributa-
Cancellation after acceptance of an order cannot be made without ble thereto, is limited to the replacement or repair of defects which,
Seller’s written consent and on such conditions as will indemnify under proper use and handling, have been proven to the Seller’s
Seller against loss for commitments made and work already com- satisfaction to arise solely from faulty design, materials or work-
plete and/or in process. manship, within a period of one (1) year from the date of shipment
Special Orders from the Seller’s factory. Further, the Seller must be notified in writ-
When Special Make Orders are accepted the entire order must be ing of the said defect or failure within a period of one (1) year from
taken. Special Make Orders cannot be cancelled or modified once the date of shipment. The replacement of such merchandise does
accepted and cannot be returned. not include expenses incurred in the installation or use of the mate-
rial. No merchandise shall be returned to the Seller’s factory or
Tolerances warehouse for credit or replacement before the Seller has officially
Non-Stock & Special Make merchandise is subject to the following advised of this transaction.
tolerances: Total product -0 and Reel lengths +/-10%, or as speci-
fied. Exact reel lengths will incur additional charges. Warranty Limitations
This warranty does not cover the repair or replacement of any
Delivery cable which fails as a result of damage in transit, misuse, neglect,
Any shipment schedule is approximate. Seller shall not be liable for accident, Acts of God, abuse, improper handling, improper storage,
any delay in delivery or failure to deliver caused in whole or in part excessive stress, faulty or improper or unauthorized installation or
by any reason beyond Seller’s control. repair, negligent maintenance or failure to comply with the written
Claims instructions for installation, use or maintenance provided by the
Buyer agrees to inspect merchandise for defects and for conform- Seller.
ity, and agrees to check material against shipping papers upon un- Exclusion of Other Warranties
loading at destination. All claims for shortages or defective This warranty is in lieu of all other warranties, express or implied,
merchandise must be made by Buyer in writing within seven (7) and all other warranties, including but not limited to the implied
days of receipt of shipment. warranties of merchantability and fitness for a particular purpose,
Returns are expressly disclaimed.
Return merchandise must be full reels or cartons, undamaged and Limitation of Liability and Limitation of Actions
in the original unopened package. Credit will be given for returned In no event shall Seller be liable for any indirect, incidental, special,
merchandise only for full reels of undamaged wire if still in the punitive or consequential loss, damage or expense (which shall be
original package. No merchandise may be returned without the deemed to include without limitation: any loss of profit or revenue,
written authority of Seller and receipt of Seller’s RMA number. No loss of goodwill, loss claimed by end-user’s customers, or loss of
merchandise may be returned after the expiration of sixty (60) days business opportunity) of any nature or kind, however arising,
following the date of shipment. Returns may be subject to a Re- whether in contract, in tort or otherwise, even if Seller is deemed to
stocking Fee. Non-Stock & Special Make merchandise will not be be aware of the possibility of such damages. Seller’s maximum lia-
considered for return and is not subject to the previous stated re- bility for any claim, loss or damage shall not exceed the purchase
turn conditions. price for the cable subject to a claim under any circumstance, even
Refunds if end-user has claims or is subject to claims in excess of this limi-
No cash refunds. Trade Credit Only. All returns and other proper tation. Any legal proceeding related to this warranty must be pre-
claims for credit may be applied toward future purchases only or sented within (1) year after the cause of action arises.
as agreed. Sole and Exclusive Remedy
Taxes This document sets forth the Seller’s sole and exclusive warranty
Liability for all taxes imposed by any government authority with re- obligation to the Buyer and the Buyer’s sole and exclusive remedy
spect to the goods herein ordered shall be assumed and paid by in the event of defective cable.
Buyer. Choice of Law
Modifications The laws of the State of Florida, without giving effect to its conflicts
Any modification of these Standard Terms and Conditions shall not of law principles, govern all matters arising out of or relating to
be binding on Seller unless signed on behalf of Seller by a repre- these Standard Terms and Conditions and all the transactions it
sentative authorized to do so, regardless of whether Seller has contemplates, including, without limitation, its validity, interpreta-
commenced shipping of any merchandise ordered hereunder or tion, construction, performance and enforcement.
whether Seller has accepted payments therefore.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. A
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Wire & Cable:
Handling and Installation Engineering Guide

Receiving and Handling Cable .............................................H1 Receiving and Handling Cable


Receipt of Cable Reels ..........................................................H1 In order to benefit from investing in underground cable (power
cable), the purchaser should put into practice a complete visual in-
1. Visually check for shipment damage............................H1 spection program that will help identify any cable that is damaged
2. Inspect reel tags .............................................................H1 during shipment. If any cable is undesirable, it is then returned to
the manufacturer instead of being installed. By recognizing and re-
3. Check dimensional tolerances ......................................H1 fusing damaged cable, one can considerably improve the depend-
Handling of Cable Reels........................................................H1 ability of the underground system.
Storage of Cable Reels ......................................................H2
Receipt of Cable Reels
Installation Suggestions .......................................................H2 Once the purchaser has received the cable shipments, they should
Safety Measures Prior to Pulling Cable ...........................H2 carry out an approval inspection. A cable approval inspection in-
volves some straightforward and low-cost steps that can yield sig-
Temperature Considerations.........................................H2
nificant dividends.
Duct Sizing......................................................................H2 The following steps should be taken to insure proper acceptance of
Jam Ratio........................................................................H2 cable:
Cable Clearance .............................................................H3
1. Visually check for shipment damage
Minimum Bending Radius (Static Conditions) ............H3 Visually check cable reels for any damage that may have taken
Minimum Bending Radius (Dynamic Conditions).......H3 place during delivery. The purchaser should be mainly worried for
cable damage if:
Cable Training (Offset Bending) ....................................H3
a. A reel is laying flat on its side, especially if it is a large conduc-
Power and Control Cables without Metallic Shielding or Armor.H4 tor size, such as 500 kcm, 750 kcm, or 1,000 kcm
Power and Control Cables with Metallic Shielding or Armor ......H4 b. Numerous reels are piled on top of each other
Clearing Ducts ................................................................H4 c. Other cargo is piled on the reel
d. Nails have been driven into the overhang to prevent overcrowd-
Trench for Direct Burial..................................................H4 ing
Rack/Trays .......................................................................H4 e. A reel overhang is broken
f. A cable covering is detached, discolored, or broken
Precautions During Cable Pulling .................................H4
g. A cable end seal is detached or broken (a broken or absent end
Cable Guides ..................................................................H4 seal means that moisture may have come into the cable)
Cable Lubricant ..............................................................H5 h. A reel has fallen (concealed damage likely)
Pulling Eyes & Grips ......................................................H5 2. Inspect reel tags
Maximum Pulling Tensions ...........................................H5 Visually check each reel to assure that it has the correct tags and la-
bels as noted in the specifications. The reel should contain the sub-
A. Pulling Eye..............................................................H5 sequent minimum information:
B. Cable grips..............................................................H6 a. Purchaser’s name and address
Sidewall Bearing Pressure (Static Conditions) ............H6 b. Purchase order number
c. Conductor size and type
Sidewall Bearing Pressure (Dynamic Conditions).......H7 d. Insulation thickness and type
Special Conditions for Metallic Armored Cables................H7 e. Jacket type
Sheath Currents and Voltages in Single Conductor Cables......H7 f. Quantity of cable on reel
g. Beginning and ending sequential footage numbers present on
Eliminating Sheath Currents.............................................H7 the jacket
Standing Voltage................................................................H8 Confirm that the cable description, reel size, and cable footage are
equivalent to that specified. Any missing information should be ac-
Installation of Single Conductor Cables in Parallel ............H8
quired from the manufacturer.
Reel Capacities...................................................................H8
NEMA Method................................................................H8 3. Check dimensional tolerances
Make a straightforward measurement of the cable dimensions on
Handling of Cables Reels......................................................H9 one reel of each size of cable in a shipment to prove that the cable’s
Shipment for Unloading with a Forklift at Dock................H10 dimensions meet the requirement.
Shipment for Unloading down an Inclined Ramp ............H10 Handling of Cable Reels
Shipment for Unloading with a Forklift at Jobsite............H10 To guarantee that material handling equipment does not touch or
Unloading from Open Flat Bed Trailers..............................H11 interfere with cable surfaces or with protective covering on the reel,
the utmost care should be taken when moving the cable reels. It is
Cable Reel Handling............................................................H12 very important that cable reels not be dropped from any height, or
Excavating, Trenching, Backfilling, and Surface be allowed to roll unrestrained. Cable reels should be moved or
Restoration...........................................................................H13 lifted using the technique depicted at the end of this document.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. H1
Copyright © 2018, American Wire Group, Inc. 20170208
Wire & Cable:
Handling and Installation Engineering Guide

1. For cranes, booms, or other overhead lifting equipment, a NOTE: If a specific method of shipping is used, such as shipping to
sturdy steel arbor or heavy rod or pipe should be placed in a job site, etc., the manufacturer must be notified of these special
through the reel hubs so that the cable reel can be lifted by requirements.
slings that make the most of spreader bars. This technique will
assure that sling pressure against a reel flange, slanting of the Installation Suggestions
reel, sliding of the sling, and other unstable situation will be re- Below you will find a general guide for the installation of shielded
duced. and unshielded cables, jacketed cables rated 600 to 35,000 volts in
2. When lifting reels by fork truck type equipment, reels should conduit, underground ducts, racks, trays or direct buried.
only be lifted from the sides, and only if the blades of the fork
truck are long enough to support both flanges. This way will Safety Measures Prior to Pulling Cable
make sure that the lift pressure is uniformly dispersed on both Temperature Considerations
flanges and not on the cable itself. It is important to consider that low temperatures create handling
3. Rolling reels containing cables should be kept to a minimum; if and pulling difficulties of varying degrees, depending on cable con-
rolling is necessary, reels should always be rolled in the direc- struction and installation location. Most cables can be safely han-
tion indicated by the “arrows” on the sides of the reel flanges or dled if not subjected to temperatures lower than -10°C (14°F) in the
in the opposite direction to which the cable is wrapped onto the twenty-four (24) hour period prior to pulling and bending the cable.
reel. Rolling the reels this way will avoid the release of the cable If temperatures do fall below these values during the following 24
wraps, which may lead to problems during installation. hour period, measures should be taken to transport the cable to a
4. It is important that any debris be cleared from the path over warm storage area. The cable should be exposed to a temperature
which the cable reels are to be rolled since that might damage of 15°C (60°F) for 24 hours to ensure warm-up. Pulling eyes, if nec-
the cable if the reels were to roll over it. Cable reels should be essary, should be set up. If the cable is installed during cold
rolled in the direction of the “Roll This Way” arrow and lowered weather conditions, cable should be pulled more slowly and
in a controlled manner. The ramps should be spaced far enough trained in place the same day it is removed from the warm storage
apart so that they are touching the reel flanges at all times. area. The cable should also not be dropped or bent if cold outside.

Storage of Cable Reels Duct Sizing


Cable reels should not be stored on their sides if at all possible. Select duct size in such a way that the difference between the hoop
To prevent deterioration of the reels and moisture seeping into the diameter of the cable(s) and the inside diameter of the duct will not
cables, it is preferable to store cable reels indoors on a hard, dry be less than ½”. Also check that the cross-sectional area of the cable
surface. is not more than the percentage of the interior cross-sectional area
of the conduit, as recommended by the National Electric Code
If cable reels are stored outdoors they must be supported off the
(NEC). In addition, consider using larger ducts or additional pull
ground and protected with a suitable weatherproof material. The
boxes if long pulls are required.
reel supports should be at least twice the width of the reel flange,
long enough to provide a sufficient load bearing surface (to pre- Jam Ratio
vent sinking), and high enough to prevent the reel from sitting in Jamming might occur in bends if three cables are pulled in parallel
free standing water in case of rain. Reel supports should be placed in duct. This happens when the cables adjust from a triangular pat-
under each reel flange, and to prevent rolling each reel should be tern to a cradled pattern as they are pulled in through the bend.
placed between the reel flange and the support at opposite sides of This pattern change will force the two outer cables to move farther
the flange. apart. The cables will also jam if the conduit diameter is too small
All cable reels should be stored in such a way so as to allow easy to contain the wider pattern.
access for lifting and moving, away from construction activities, To prevent this, the jam ratio should be checked. The jam ratio cor-
falling or lying objects, sources of high heat, open flames, chemi- responds to the inside diameter of the duct to the cable diameter,
cals or petroleum products, etc. that may cause damage to the such that:
cable. It is also recommended to use fences or any other suitable
barriers to protect cables and reels against damage by vehicles or J=D÷d
other moving equipment in the storage area.
Where:
If the cable is stored on reels for future use after the factory applied
J = Jam ratio
end caps are removed, the exposed cable ends MUST be re-sealed
using properly applied weatherproof end caps or by taping the D = Inside diameter of duct (in)
ends with a tape designed to prevent moisture. PVC tapes or Duct d = Outside diameter of cable (in)
Tape are not appropriate for preventing moisture. One must secure The proper cable configuration can be determined if the above jam
the loose ends of the cable reels to the reel flange and cannot lie ratio is calculated. The likely configurations are as follows:
on the ground. Jam Ratio Cable Configuration
Reels and end caps should be inspected from time to time if they J < 2.4 Triangular
will be stored outside for a long period of time. A once a month in- 2.4 < J < 2.6 More likely triangular
spection is suitable at first but one should consider increasing this 2.6 < J < 2.8 Either triangular or cradled
if storage time is extended since wooden reels tend to deteriorate 2.8 < J < 3.0 More likely cradled
over time and sealed end caps will lose their usefulness. Rates of J > 3.0 Cradled
deterioration will vary depending on the environment in which the
reels are stored.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
H2 Information on this sheet subject to change without notice.
20170208 Copyright © 2018, American Wire Group, Inc.
Wire & Cable:
Handling and Installation Engineering Guide

Cable jamming tends to occur between J = 2.8 and J = 3.1. This is calculating conduit or tubing fill. The actual dimensions of the
true if the sidewall bearing pressure (SWBP) in a bend surpasses equipment grounding or bonding conductor (insulated or bare)
the 1,000 lbs/foot. shall be used in the calculation.”
The below formula can be used when a calculation must be made
Cable Clearance to comply with the NEC fill ratio requirements:
In order to make sure that the cables can be pulled through the
conduit, specifically in applications where the National Electric FR = [NPC x (PCD ÷ 2)2 + NGC x (GCD ÷ 2)2] ÷ (CD ÷ 2)2
Code (NEC) limits on conduit fill do not apply, one needs to calcu-
Where:
late the clearance between the cable(s) and conduit. The recom-
mended calculated clearance should not be less than 0.5 inches. FR = Fill Ratio (%)
However, a lesser clearance, such as 0.25 inches, may be suitable NPC = Number of Phase Conductors with the same diameter
for primarily straight pulls. PCD = Diameter of Phase Conductor (in)
In addition, the clearance should contain the pulling eye or cable NGC = Number of Ground Conductors with the same diameter
grip, which is used for the cable pull. The formulas below can be
used to calculate the cable clearance for a single cable pull and for GCD = Diameter of Ground Conductor (in)
a three-cable pull. (Please Note: To allow for differences in cable CD = Diameter of Conduit or Duct (in)
and duct dimensions and ovality of the duct at bends, the nominal
cable diameter “d” has been increased by 5%). Minimum Bending Radius (Static Conditions)
a. Single Cable Pull The following formula can be used to determine the minimum val-
ues for the radii to which such cables may be bent for permanent
C = D – 1.05 x d training:
b. Three Cable Pull (triangular pattern)
MBR = OD x M
D (D – 1.05 x d) 1.05 x d 2
C = __ – 1.366 (1.05 x d) + ____________ x
2 2
1–
[ ____________
(D – 1.05 x d) ] Where:
MBR = Minimum radius of bend (in)
Where: OD = Outside diameter of cable (in)
C = Cable clearance (in)
M = Diameter multiplier (Please see tables on the next page(s))
D = Inside diameter of duct (in)
Note: The above calculation applies to STATIC conditions ONLY.
d = Outside diameter of cable (in) Please reference the DYNAMIC conditions section below and the
Please reference the following table in dealing with applications Sidewall Bearing Pressure section for the minimum bending radius
where the National Electric Code (NEC) is compulsory. The table of cable in motion.
shows the most ordinary scenarios concerning the fill ratio of
many cable configurations in various duct sizes. Minimum Bending Radius (Dynamic Conditions)
The following formula can be used to determine the minimum val-
Conductor Fill Per NEC Code
ues for the radii to which such cables may be bent while being
Duct 1 Conductor 2 Conductors 3 Conductors 4 conductors
pulled into an installation and while under tension. This value will
Sizes (53% Fill Ratio) (31% Fill Ratio) (40% Fill Ratio) (40% Fill Ratio)
largely depend on the tension the cable experiences as it exits the
(in) Area Dmax Area Dmax Area Dmax Area Dmax
bend. The greater the exiting tension, the greater the minimum-
(in2) (in) (in2) (in) (in2) (in) (in2) (in)
bending radius will be for the cable.
½ 0.16 0.453 0.09 0.245 0.12 0.227 0.12 0.197
¾ 0.28 0.6 0.16 0.324 0.21 0.301 0.21 0.261 MBR = (Te ÷ SWBP) X 12 (in)
1 0.46 0.764 0.27 0.413 0.34 0.383 0.34 0.332 Where:
1¼ 0.80 1.005 0.47 0.543 0.60 0.504 0.60 0.436 MBR = Minimum radius of bend (in)
1½ 1.08 1.172 0.63 0.634 0.82 0.588 0.82 0.509 Te = Tension as cable exits the bend (pounds x force)
2 1.78 1.505 1.04 0.814 1.34 0.755 1.34 0.654 SWBP = Maximum allowable Sidewall Bearing Pressure (pounds
x force per foot of bend radius)
2½ 2.54 1.797 1.48 0.972 1.92 0.902 1.92 0.781
3 3.91 2.234 2.26 1.208 2.95 1.12 2.95 0.97 Cable Training (Offset bending)
3½ 5.25 2.583 3.07 1.397 3.96 1.296 3.96 1.122 You may use the following formula to determine the minimum dis-
tance necessary for permanent cable training (offset bending) in a
4 6.74 2.931 3.94 1.585 5.09 1.47 5.09 1.273 manhole:
5 10.60 3.674 6.20 1.987 8.00 1.843 8.00 1.596
6 15.31 4.415 8.96 2.388 11.56 2.215 11.56 1.918 L = S (4 R – S)
Please Note: “dmax(in)” is the maximum single conductor diameter Where:
that will comply with the above requirements. “Area (in2)” is the
area of the conductor(s). Ground wires have not been considered L = Minimum distance required (in)
in the above table. The NEC requires that “Equipment grounding S = Offset (in)
or bonding conductors, where installed, shall be included when R = Bending radius to cable centerline (in)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. H3
Copyright © 2018, American Wire Group, Inc. 20170208
Wire & Cable:
Handling and Installation Engineering Guide

*For conductor sizes 1500kcm and larger, the minimum bending radius for
S LC Shielded cable is 18X the cable diameter.
Note 1: Multiply the diameter of the cable by the factor in the table
above to attain the minimum-bending radius.
Note 2: These limits may not be appropriate for use with conduit
bends, sheaves or other curved surfaces around which the cable
may be pulled under tension while being installed due to sidewall
bearing pressure limits. The minimum radius specified refers to the
L
inner radius of the cable bend and not to the axis of the cable.
R
Clearing Ducts
Using a plug that is roughly the same diameter as the inside of the
duct does not permit obstructions in the duct since it pulls the plug
through the structure. After doing this, use a wire brush to clean
Allow a suitable length of straight cable at both ends of the offset and remove foreign matter from the duct. In order to prevent
bend. scratch damage to the cable jacket during pulling, it is important to
smooth the interior.
Power and Control Cables without Metallic Shielding or Armor
Insulation Overall Diameter of Cable Trench for Direct Burial
Thickness (in) To prevent damage to the cable jacket during or after cable installa-
(mil) 1.000 and Less 1.001 to 2.000 2.001 and Over tion, the trench should be clean of sharp stone, glass, metal or
Minimum Bending Radius as a Multiple of Cable Diameter wood debris. The trench bottom should be evenly covered with a
155 and less 4 5 6 layer of soil or sand that has been screened through a medium-to-
fine mesh screen to remove all larger stones or other material. This
156 to 310 5 6 7
will assure a smooth, soft-bedding surface for the cable(s). It is a
310 and over — 7 8 good idea to lay a protective covering on the fill about 6-8 inches
Note 1: The highest applicable multiplier should be used in all above the cable to protect it if working in an urban area or near
cases. The calculated minimum bend radius (applicable multiplier x where a lot of digging occurs. If working under highways or rail-
outside diameter of cable) refers to the inner surface of the bent road rights-of-way, it is also a good idea to install the cable in a
cable, and not the axis (centerline) of the cable conduit. pipe or conduit to give added mechanical protection.
Note 2: Use the thickest of the insulations of the cables within the Rack/Trays
assembly and the diameter of the largest single cable within the One should check the entire path that the cable will follow during
cable assembly to determine the multiplier. Afterwards, apply that pulling to make sure that the cable will have a smooth ride, free of
multiplier to the diameter of the overall assembly. all barriers or sharp edges. In checking this, one should consider
Note 3: The minimum values for the radii to which cables may be the position the cable will take on when under tension.
bent during installation may not apply to conduit bends, sheaves
or other curved surfaces around which the cable may be pulled Precautions During Cable Pulling
under tension while being installed. Larger radii bends may be re- Cable Guides
quired for such conditions. (Please reference “Precautions during All guides should be in the form of large diameter, smooth-sur-
Cable Pulling” in the “Sidewall Bearing Pressure” section). faced, free-turning sheaves or rollers to prevent damage to the
cable jacket when guiding the cable from the reel to the duct
Power and Control Cables with Metallic Shielding or Armor mouth or trench. Guide tubes or chutes must be smooth, burr-free
Cable Type Minimum Bending Radius Minimum Bending Radius working surfaces with the largest possible bend radii and be se-
For Single Conductors For Multiple Conductors† curely anchored if used. Mounting the cable reel in sturdy jacks,
Interlocked and Polymeric leveling the reel shaft and lubricating the reel arbor holes with
Armor (without shielded grease will lead to low cable tension. If breaking the reel needs to
conductor) 7 7 happen, it should only be done to prevent reel over-run when the
Interlocked Armor and pull is slowed or stopped, or on steep downhill runs where cable
Polymeric Armor (with weight is enough to overcome cable-duct friction.
shielded conductor) 12 7 This information also applies for rack or tray installations. The fol-
Wired Armored Cable 12 12 lowing points should be noted when making such pulls:
Metallic Tape Shielded Cable 12 7 1. Cable support rollers should be spaced close enough so that the
Metallic Fine Wire Shield 12 7 cable’s normal sag, even when under tension, will not result in
Concentric Neutral Wire tray dragging.
Shielded Cable 8 5 2. The cable rollers should be contoured so that the cable will not
Lead Sheath Cable 12 7 ride off the end of the roller or be “pinched” into a sheave con-
LC Shielded Cable 12* 7 tour diameter that is smaller than that of the cable.
3. When rollers or sheaves are used to guide the cable through the
† Use the larger of the two minimum bending radii when considering the
bends, it is important that enough of them be used to guide the
minimum-bending radius for multiple conductors.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
H4 Information on this sheet subject to change without notice.
20170208 Copyright © 2018, American Wire Group, Inc.
Wire & Cable:
Handling and Installation Engineering Guide

cable in a smooth curve of the desired radius from tangent secure the armor at the cut point with friction tape before cut-
point to tangent point. If this is not done, the cable may be ting.
“kinked” around the radius of each roller. 4. Apply four, 3-inch long, tight wrappings of friction tape. Place
The cable may be paid off the reel and laid into the trench as the this tape on a) the end of the core, b) on the core to the edge of
reel is moved along the length of the trench in cases of direct-bur- the sheath/armor, c) on the jacket, or sheath/armor to the edge
ial installations. When this happens, the cable is laid on a bed of of same, and d) on jacket, or sheath/armor where the last 3
soil or sand. inches of grip will be.
If the cable needs to be pulled through the trench, the best way to 5. If cable will be exposed to moisture during the pull, seal the cut
do so is to support the cable on temporary rollers so that the cable ends of the conductors with sealing mastic and vinyl tape, or
does not drag over the soil or sand bed. If one does not have heat-shrinkable cap(s).
rollers handy, sacks filled with very fine sand or other fine powdery 6. Place the grip on the cable and secure it tightly by “milking” it
material may be used as an alternative to support the cable and from the cable end towards the end of the grip.
keep it from dragging on the trench bed during the pulling process. 7. Clamp the back end of the grip to secure it to the cable with a
steel hose clamp, such as the “Band-It” types, or a tough steel
Cable Lubricant wire that is firmly applied.
To reduce pulling tensions and damage on cables, lubricants may 8. Over the clamp apply a tape wrapping to smooth it and prevent
be used in conduit. When using cable or pulling lubricants, one drag during the pull.
should avoid compounds that may contain oils or greases since CAUTION: The ends of cable pulled this way will not be entirely
they may damage the cable jackets. Also, pulling lubricants that safe from water. If this is an issue, properly applied pulling eyes
contain micro-spheres or micro-balls should be avoided for should be used.
medium-voltage cable installations. These kinds of lubricants are *NOTE: The force applied by pulling a grip may damage or disrupt
meant to be used on low-tension pulls that are not representative the underlying cable, so it is best to cut off the section immedi-
of power cable pulls. ately below the grip as well as the three feet of cable behind the
Most commercially available pulling lubricants can be used with lit- grip before fixing together.
tle worry for compatibility. But, one does need to keep in mind that
some pulling lubricants react poorly to some cable jacket com- Maximum Pulling Tensions
pounds, which may lead to ruining the cable jacket. It is best to To prevent damage to the cable, pulling tensions for installing elec-
avoid damage to the cable jacket by consulting the cable manufac- trical cables should be maintained as low as possible. This may be
turer regarding lubricant compatibility with specific jacket com- done through proper use of size ducts or conduits, by avoiding
pounds. long pulls, and avoiding runs that may contain sharp bends or se-
vere changes in elevation.
Pulling Eyes & Grips The following maximum allowable pulling tension must not be
Pulling eyes attached to the cable conductor(s) are used for large, passed when pulling cable by the method indicated.
heavy cable, or for cables where the pulls are very long or contain
numerous bends. To use the pulling eye, one must fasten it directly A. Pulling Eye
to the conductor(s) on the end of the cable by soldering the copper The maximum tension for cables pulled with a pulling eye should
conductors into a socket-type eye, or by mechanically compressing not exceed the value calculated using the following formula:
the aluminum conductors into an aluminum eye. Then, a tape seal
or heat-shrinkable tube is placed over the eye-cable joint to provide Tmax = CTC x CA x N
a reliable weather-tight seal for the cable during pulling. For ar- Where:
mored cables, the armor needs to be properly secured to the eye to
insure the reliability of the cable during pulling. Generally, pulling Tmax = Maximum pulling tension (lb)
eyes tend to be installed at the factory; however, they can also be CA = Conductor Area (cmil)
installed in the field. N = Number of conductors being pulled
Often times, woven wire pulling grips, generally called “baskets” CTC = Conductor Tension Constant
are used to pull armored cables; they are well suited for pulling
smaller size voltage cables, or where the pulls are fairly short. Spe- For CTC with aluminum compression eyes or blots use:
cial measures need to be taken if using “baskets” on Interlock Ar- 0.011 — Copper conductor
mored cables to avoid damage to the cable or problems in making 0.008 — Aluminum Stranded conductor
the pull. The puling grip may tend to stretch the armor if the grip is
0.006 — Aluminum Solid conductor
not properly secured to the cable. The following method for prepar-
ing the cable and attaching the grip is advised: For CTC with filled eyes or bolts use:
1. Select the grip size that fits the cable diameter or armor best. 0.013 — Copper conductor
Determine the length of the gripping portion of the grip. 0.011 — Aluminum Stranded conductor
2. Find two points on the end of the cable. The first is 75% of the 0.008 — Aluminum Solid conductor
grip length from the end; the second is 100% of the grip length
from the end. NOTE: When calculating the maximum pulling tension, DO NOT
3. Get rid of the sheath/armor, and also the outer jacket if there, to consider the area of neutral or grounding conductors in cable(s).
the first mark. Do not damage the core of the armor. If need be, The number of conductors should be reduced by one (1) when cal-

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. H5
Copyright © 2018, American Wire Group, Inc. 20150116
Wire & Cable:
Handling and Installation Engineering Guide

culating the maximum tension for parallel cable assemblies. The † Interlock Armor pulling tension using pulling grips should be limited to the
“N” can equal the number of cables in the assembly, excluding lesser of the value provided above or 50% of value of Tmax calculated using
ground wires. This number can also be reduced by one (1) as an “Pulling Eye” formula.
extra measure. Note 1: The above tensions correspond to three cables in one grip.
The stress on the cable conductor should not exceed 16,000 psi
Pulling Eye Maximum Pulling Tension (lbs) (0.013 lbs/cmil) for annealed copper conductors when using a grip.
Size Copper Stranded Aluminum For stranded ¾ and full hard aluminum conductors the stress
1/C 3-1/C 3-1/C 1/C 3-1/C 3-1/C should not exceed 14,000 psi (0.011 lbs/cmil) and 10,000 psi (0.008
Single Parallel Triplex Single Parallel Triplex lbs/cmil) for solid ½ to full hard aluminum conductors. The allow-
8 AWG 181 362 543 132 264 396 able conductor stress should be based on two cables sharing a
7 AWG 229 458 687 166 332 498 load for three single conductor cables in parallel and triplexed con-
6 AWG 288 576 864 209 418 627 figurations.
5 AWG 363 726 1089 264 528 792 Note 2: The manufacturer of the cable(s) used should be contacted
4 AWG 459 918 1377 333 666 999 to determine the mechanical limitations of the cable(s).
3 AWG 578 1156 1734 420 840 1260 Note 3: It is recommended that pulling grips be used during instal-
2 AWG 729 1458 2187 530 1060 1590 lation of Polymeric Armored Cables, due to their higher sidewall
bearing pressure capabilities.
1 AWG 920 1840 2760 669 1338 2007
1/0 AWG 1161 2322 3483 844 1688 2532 Pulling Grips Maximum Pulling Tension (psi)
2/0 AWG 1464 2928 4392 1064 2128 3192 Type of Cable PE, XLP Insulated EPR Insulated Paper Insulated
3/0 AWG 1845 3690 5535 1342 2684 4026 Single Multiple Single Multiple Single Multiple
4/0 AWG 2327 4654 6981 1692 3384 5076 Cable Cables Cable Cables Cable Cables
250 kcm 2750 5500 8250 2000 4000 6000 Lead Shielded 16000 16000 8000 8000 1500 1500
300 kcm 3300 6600 9900 2400 4800 7200 (Note 4) (Note 4) (Note 5) (Note 5) (Note 6) (Note 6)

350 kcm 3850 7700 11550 2800 5600 8400 Note 4: The maximum pulling tension stress limit for pulling grips
400 kcm 4400 8800 13200 3200 6400 9600 on lead sheathed cable with XMPLE/TRXLPE insulation is 16,000
psi of lead sheath area for a single cable as well as one grip on
450 kcm 4950 9900 14850 3600 7200 10800
three cables (per AEIC CG5-2005).
500 kcm 5500 11000 16000 4000 8000 12000
Note 5: The maximum pulling tension stress limit for pulling grips
550 kcm 6050 12100 18150 4400 8800 13200 on lead sheathed cable with EPR insulation is 8,000 psi of lead
600 kcm 6600 13200 19800 4800 9600 14400 sheath area for a single cable as well as one grip on three cable
650 kcm 7150 14300 21450 5200 10400 15600 (per AEIC CG5-2005).
700 kcm 7700 15400 23100 5600 11200 16800 Note 6: The maximum pulling tension stress limit for pulling grips
750 kcm 8250 16500 24750 6000 12000 18000 on lead sheathed cable with Paper insulation is 1,500 psi of lead
800 kcm 8800 17600 26400 6400 12800 19200 sheath area for a single cable as well as one grip on three cables
900 kcm 9900 19800 29700 7200 14400 21600 (per IPCEA P-41-412-1958).
1000 kcm 11000 22000 33000 8000 16000 24000
Sidewall Bearing Pressure (Static Conditions)
B. Cable Grips The dynamic radial pressure of cable which is pulled around a
When using a cable grip to pull cables, the maximum tension bend under pulling tension should be kept as low as possible and
should not exceed the value shown in the following two tables, or not exceed the following values listed in the table. To calculate
the formula used in the table above. these values use the following formula:
PSW = Te ÷ Br
Pulling Grips Maximum Pulling Tension (lbs)
Where:
Type of Cable PE, XLP Insulated EPR Insulated
Single Multiple Single Multiple PSW = Sidewall Bearing Pressure in pounds per foot of bend
Cable Cables Cable Cables radius
Unshielded, with or without Jacket 2000 2000 2000 2000 Te = Pulling Tension as cable exits the bend (lbs)*
Concentric Wire URD with Jacket 10000 5000 10000 10000 Br = Bend radius, in feet
Concentric Wire URD without Jacket 10000 5000 6000 3000 *Note: The maximum pulling tension determined by the above for-
Taped Shielded with Jacket 10000 5000 10000 10000 mulas must be observed.
Fine Wire Shielded with Jacket 10000 5000 10000 10000
LC Shielded with Jacket 8000 4000 5000 2500
Polymeric Armored Cables (See Note 3) — — 10000 10000
Interlock Armor with PVC Jacket 5000† — 5000† —
Interlock Armor with Poly Jacket 5000† — 5000† —
Lead Sheathed Cables See Subsequent Table

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
H6 Information on this sheet subject to change without notice.
20170208 Copyright © 2018, American Wire Group, Inc.
Wire & Cable:
Handling and Installation Engineering Guide

Sidewall Bearing Pressure (Dynamic Conditions) centric grounding conductor are bonded or grounded at more than
To calculate the minimum bending radii for dynamic conditions, one (1) point. The magnitude of the induced voltage is relative to
use the following formula: the magnitude of the current in the phase conductor. The magni-
tude of the sheath currents is a function of the induced voltage and
MBR = (Te ÷ PSW) x 12 the sheath impedance. The armor and the grounding conductor can
Where: become very hot if the sheath current is large. If this occurs, the
MBR = Minimum Bending Radius (in) conductor insulation will also be subjected to temperatures that
may cause electrical failure or reduce the life expectancy of the
Te = Pulling Tension as cable exits the bend (lbs)* cable.
PSW = Maximum Sidewall Bearing Pressure in pounds per foot One will have to derate the cable if sheath currents are large
of bend radius from following table enough to raise the temperature of the insulation above its rated
*Note: The maximum pulling tension determined by the above for- value.
mulas must be observed. In a single conductor cable carrying currents less than 180 amps,
sheath currents will not pose a problem since induced voltages and
Sidewall Bearing Pressure (lbs/ft of bend radius)* sheath impedances minimize sheath losses.
Type of Cable PE, XLP EPR In single conductor cables carrying currents between 180 and 425
Insulated Insulated amps, sheath currents will not pose a problem if the cables are
Unshielded, without Jacket 1200 500 spaced about one (1) cable diameter apart. When this spacing is
Unshielded, with Jacket 1200 1000 done, mutual heating is minimized and the induced voltage is re-
Interlock Armor with PVC Jacket duced by virtue of field cancellation.
Single Conductor & Three Conductor In single conductor cables carrying currents larger than 425 amps,
having round core (100% fillers) 800 800 it is normally necessary to derate the cables to avoid overheating
Interlock Armor with Poly Jacket unless the sheath currents are removed.
Single Conductor & Three Conductor Armor of magnetic material (such as galvanized steel) should not
having round core (100% fillers) 1000 1000 be used on single conductor cables intended for use in AC circuits.
Concentric Wire URD, without Jacket 1200† 1000†
Eliminating Sheath Currents
Concentric Wire, Encapsulating Jacket 2000 2000
One needs to make sure that all paths by which sheath currents cir-
Concentric Wire, with Sleeved Jacket 1500 1500 culate are kept open in order to prevent the current from flowing.
LC Shielded with Jacket 1500 1500 One should ground and bond cable armors and concentrically ap-
Taped Shielded with Jacket 1500 1500 plied grounding conductors at the supply end only and afterwards
Fine Wire Shielded with Jacket 1500 1500 isolated from ground and each other. Isolation may be established
when installing cables in individual ducts by using cables with PVC
Teck-90 Cable, Single Conductor & Three jackets or other insulating materials, or also by mounting cables.
Conductor having round core (100% fillers) 800 800
No sheath current will flow if the armors and concentrically applied
Teck-90 Cable, Three Conductor
grounding conductors are bonded and grounded at the supply end
with minimal or no fillers 350 350
through a non-ferrous metal panel and mounted on an insulated
Lead Sheathed (Solid Dielectric) 2000** 2000** panel at the load end. For an illustration of this, please see the fig-
Polymeric Armored Cables Air Bag® 2400 ure down below.
AirGuard® 3000 a) Cables enter supply end enclosure through metallic non-ferrous
Lead Sheath (PILC) 400 panel to avoid overheating. Cable armors are bonded through
† Value shown corresponds to a single conductor cable pull. Maximum Side- panel.
wall Bearing Pressure limits of 750 and 200 lbs. per foot, respectively, are b) Cable enters load end enclosure through panel of insulating ma-
recommended for a three-conductor pull. terial. The insulating material maintains the open circuit of the
* For a pulling eye/pulling grip, the maximum pulling tension must be ob- armors.
served in addition to the maximum sidewall bearing pressure limit. c) Cable armors and concentrically applied grounding conductors
** These values are based on the cross-sectional area of one lead sheath. are bonded and grounded at the supply end only. When in-
Note 1: It is recommended that the manufacturer of the cable(s) in stalled in this way, the armor and concentric grounding conduc-
question be contacted concerning the mechanical limitations of tor do not form a part of the system ground circuit and a
the cable. separate ground conductor should be installed, following the
proper electrical code.
Special Conditions for Metallic Armored Cables d) All cable connectors and lock nuts are made of non-magnetic
metal (aluminum or other).
Sheath Currents and Voltages in Single Conductor Cables
A voltage is induced in the concentrically applied wires of the
grounding conductor and the armor in a single conductor cable
with an interlocking armor.
A current will flow in the completed path if the armor and the con-

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. H7
Copyright © 2018, American Wire Group, Inc. 20170208
Wire & Cable:
Handling and Installation Engineering Guide

Standing Voltage Installation of Single Conductor Cables in Parallel


An induced voltage will exist between ground and both the armor
and the concentric grounding conductor throughout the length of
the cable when single conductor cables are installed, as shown in
the figure below:
SUPPLY LOAD
END END

Non-Ferrous Panel of
Metal Panel Insulating
Materials

Connectors & Locknuts


of Non-Ferrous Material

Metallic Shield
Separate Ground Conductor Cut-Off Inside
Enclosure Close
to Connector Notes:
Metal Enclosure
1. S = Separation of groups. This equals the width of one group.
2. Horizontal and vertical separation between adjacent cables
should be a minimum of one (1) cable diameter to benefit from
The magnitude of this voltage is proportional to the phase conduc- the ampacity in free air in a ventilated cable tray.
tor current, the cable length and the spacing between the cables. 3. Neutral conductors can be located outside of the above groups.
The magnitude of the “standing voltage” is usually limited to about
25 volts. Please be aware that some Electrical Inspection Authori- Reel Capacities
ties limit this voltage to a lower amount. NEMA Method
By grounding the armor and the concentric grounding conductor at The formula for calculating footage capacities of reels for round
the midpoint of the cable run, one can limit the standing voltage cable is shown below. A 5% factor and 95% traverse utilization
and also increase the circuit length. If doing this, the cable must go have been built into the formula. Cables must be wound evenly to
through a junction box at the midpoint of the run and must be con- obtain consistency.
nected on each side of the junction box as shown on the supply
end of the figure above. In this case, the cables at both the supply
and load ends must be connected through panels of insulating ma-
terial to prevent the flow of sheath currents. Nevertheless, when
f
12 {[ (A–2xX–B *
1.9 – D )
F = __ B + ____________ 0.95 x D ____________
1.9 – D
0.95 x C *
A – 2 x X – B * ________
][ D ][ ]}
two (2) or more single conductor cables are installed in parallel per * Round off the result to the nearest whole number.
phase, grounding at the midpoint is not allowed. For more on in-
stalling single conductor armor cables in parallel please see the di-
agram below, which depicts symmetrical configurations: Where:
F = Feet of cable on reel
A = Flange diameter, in inches
B = Drum diameter, in inches
C = Inside traverse, in inches
D = Cable diameter, in inches
X = This variable is defined as the distance between the cable
and the outside edge of the reel flange. Clearance is equivalent
to 1 inch or 1 cable diameter, whichever is the larger quantity.
Note: The NEMA formula does not cover paralleled or triplexed as-
semblies. Contact the cable manufacturer for the maximum
footages of these assemblies.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
H8 Information on this sheet subject to change without notice.
20170208 Copyright © 2018, American Wire Group, Inc.
Wire & Cable:
Handling and Installation Engineering Guide

Handling of Cables Reels

YES NO

Reels should be lifted with a shaft extending through both flanges. Inspect all reels. Reels laying flat should be refused or received
subject to inspection.

Reels should be lowered using hydraulic gate, hoise or forklift. Do NOT allow forks to touch cable or reel wrap.
LOWER CAREFULLY.

Load with flanges on edge and chock securely.. Never drop reels from trailer.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. H9
Copyright © 2018, American Wire Group, Inc. 0140401
Wire & Cable:
Handling and Installation Engineering Guide

Shipment for unloading with a forklift at dock

Shipment for unloading down an inclined ramp

Shipment for unloading with a forklift at jobsite

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
H10 Information on this sheet subject to change without notice.
20170208 Copyright © 2018, American Wire Group, Inc.
Wire & Cable:
Handling and Installation Engineering Guide

Unloading from Open Flat Bed Trailers

Spacer Bar

CORRECT

Reel Tongs

INCORRECT

Winch Line

INCORRECT

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. H11
Copyright © 2018, American Wire Group, Inc. 20170208
Wire & Cable:
Handling and Installation Engineering Guide

Cable Reel Handling

Do NOT allow forks to touch cable or reel wrap. Do NOT allow forks to touch cable or reel wrap.

Do NOT allow forks to touch cable or reel wrap. Do NOT allow forks to touch cable or reel wrap.
This method OK for Low Voltage Cable only!

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
H12 Information on this sheet subject to change without notice.
20170208 Copyright © 2018, American Wire Group, Inc.
Wire & Cable:
Handling and Installation Engineering Guide

Excavating, Trenching, Backfilling, and Surface Restoration Drain Tile Repairs


Contractor shall use good engineering and construction practices
PRODUCTS
to minimize damage to existing drainage tiles and waterways in
Excavated Backfill Materials
order to minimize damage to existing drainage. Contractor shall
• Backfill shall be free of roots, stumps, rubbish, and stone, con-
consult with landowners to determine locations of existing tiles, if
crete and clay lumps larger than one-third cubic foot.
known, prior to construction.
• Remove and dispose of unsuitable material in backfill.
In the event that Contractor damages drainage tiles or waterways
EXECUTION during construction, Contractor shall repair or replace the dam-
Preparation aged tiles and restore the damaged waterways, either at their origi-
• Verify location of existing underground utilities. nal location or at such other location as will accomplish their
• Protect all existing underground facilities. original purpose.
• Protect all existing above ground facilities and structures.
Suitable fill material shall be placed under the repaired or replaced
• Provide for continuance of use of all utilities.
tile to minimize settling.
Trenching Contractor shall coordinate drainage tile repair such that
• Cut existing surfaces to expose area for trenching. Landowner’s representative may observe such work by Contractor,
• Bore below all asphalt surfaces. provided such representative must be available in accordance with
• No classification of excavated material will be made. Grantee’s construction schedule.
• Strip topsoil and stockpile for replacement/restoration
• Excavate trench to required line and grade. All underground power lines (including ground cables) shall be in-
• Keep trench width to a minimum to allow proper jointing of util- stalled at least 4 feet below finished ground elevation. During con-
ity and compaction of bedding and backfill. struction, if Contractor encounters underground drainage tiles
• Organize operations to keep time of open trench to a minimum. while trenching for underground lines, Contractor shall install un-
• Excavation by blasting will not be allowed. derground lines below the drainage tiles unless the drainage tiles
• Trench bottom shall be firm for entire length and width. are 6 feet or more below the surface, in which case the under-
• Remove unstable material from trench bottom and replace with ground lines shall be installed above the drainage tiles.
approved bedding. Upon Completion of the work, Contractor shall provide a site map
• Remove rock, shale and hardpan to one foot below bedding ele- showing the “as built” location of the underground transmission
vation and replace with approved foundation material. lines on the Property.
• Keep trenches free from water.
TESTING
• Dispose of excavated material not used or suitable for use as
Backfill Compaction Test
backfill.
Compaction tests shall be performed at a depth of one and 1.5 feet
• Stabilize unstable trench walls.
above the cables and 3 feet above the cables.
• Protect bottom of trench from frost. Do not place structures or
conduit on frozen ground. Compaction tests shall be performed every 500 feet for the first
mile and every mile thereafter.
Backfilling and Compacting
• Do not start encasement backfilling until work which will be cov- Care is to be taken when compacting under, alongside, and imme-
ered is completed and areas are free of foreign material. diately above the cable to avoid crushing the insulation and to pre-
• Restore underground facilities interfered with to original condi- serve the trefoil configuration of the cable.
tion. Compaction Test Failure
• Place minimum of two feet of backfill over initial encasement be- If the required state of compaction is not obtained, it shall be the
fore beginning compaction operations. responsibility of the Contractor to re-compact or rework the mate-
• Compaction by flooding will not be allowed. rial to the required state of compaction. In cases where there is a
• Level depressions in finished trench. failure to achieve the required state of compaction it may be re-
• Replace topsoil. quired that the backfill be removed and re-compacted or replaced
• Backfill compaction - 85% of standard proctor density unless oth- at the discretion of Engineer and/or Owner.
erwise specified on drawings.
° Testing fees will be paid by the Contractor.
Surface Restoration
• Provide surface restoration to match existing conditions.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. H13
Copyright © 2018, American Wire Group, Inc. 20180201
NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Jacket Material Selection Chart

PVC Polyethylene Neoprene Chlorosulphonated Thermoplastic


Polyethylene CP
Mechanical
Abrasion Resistance Good Excellent Good Good Excellent
Tensile Strength Excellent Excellent Excellent Excellent Good
Elongation Good Excellent Excellent Excellent Good
Compression Resistance Good Excellent Excellent Excellent Good
Flexibility Good Fair Excellent Excellent Fair

Environmental
Flame Good Poor Excellent Excellent Good
Fresh Water Good Exceptional Excellent Excellent Excellent
Salt Water Good Exceptional Excellent Excellent Excellent
Motor Oil Good Excellent Good Good Good
Fuel Oil Good Slight swelling above 60°C Good Good Poor above 110°C
Crude Oil Good Slight swelling above 60°C Good Good Poor above 110°C
Creosote Poor Good Fair Fair Good
Gasoline Good Excellent Poor Poor Excellent
Kerosene Good Slight swelling at Slight swelling at
higher temperature Poor Poor higher temperature
Isopropyl Alcohol Fair Good Fair Good Good
Wood Alcohol Fair Good Fair Good Good
Grain Alcohol Fair Good Fair Good Good
Sulfuric Acid Excellent Excellent Excellent Excellent Excellent
Nitric Acid Excellent Excellent Excellent Excellent Excellent
Hydrochloric Acid Excellent Excellent Excellent Excellent Excellent
Sodium Hydroxide (Lye) Good Excellent Good Excellent Excellent
Potassium Hydroxide (Potash) Good Excellent Good Excellent Excellent
Calcium Hydroxide (Lime) Good Excellent Poor Fair Excellent
Acetone Poor Excellent Poor Fair Good
Methyl Ethyl Ketone (MEK) Poor Good Poor Fair Good
Ethyl Acetate Poor Good Poor Fair Good
Lacquer Thinner Poor Good Poor Fair Good
Chloroform Poor Good Poor Fair Good
Carbon Tetrachloride Poor Good Poor Fair Good
Methyl Chloride Poor Poor Poor Poor Poor

General
Leaves protective residue
after combustion Yes No Yes Yes Yes
Oxygen index (ASTMD-2863) 23-30% 17-18% 31-39% 30-36% 30-34%
Halogen content - % weight 26 0 18 14 18-20
Minimum installation temperature -10°C -40°C -20°C -20°C -40°C
Dimensional stability underheat Fair Fair Excellent Excellent Fair
Maximum operating temperature 75°C 75°C 90°C 90°C 75°C
Note: When cables are to be installed in cold weather, they should be kept in heated storage for at least 24 hrs. before installation.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. K
Copyright © 2018, American Wire Group, Inc. 20150309
NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Insulation Performance Specifications

EPR Performance Specifications TRXLPE Performance Specifications


The insulation shall be a premium quality, heat, moisture, ozone Suitable for use for the following specifications
and corona resistanthermosetting ethylene propylene; TYPE I, II or • AEIC CS8
III as listed in ICEA S-93-639 or ICEA S-97-682. The cable manufac- • ICEA S-94-649
turer shall compound the insulation material with in its own or re- • ICEA T-31-610
motely owned facilities. The insulation shall be compatible with • ICEA T-34-664 as applicable for TRXLPE insulated concentric neu-
both the conductor shield and the insulation shield. The thickness tral cable
shall be at the 100% or 133% level as applicable and in accordance • UL 1072 MV-90 or MV-105
with the latest edition of ICEA. • CSA Standard C68.5-07
S-93-639, ICEA S-97-682 and UL 1072. The diameters over the insu- ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral
lation shall be in accordance with ICEA S-97-682. The EPR insula- cable must conform to the following chart:
tion shall also meet the guaranteed values as listed in the table
below.
PHYSICAL PROPERTIES UNIT TEST METHOD VALUE
PHYSICAL REQUIREMENTS GUARANTEED Density (Base Resin) g/cm3 ASTM D1505 0.921
VALUE Tensile Strength kg/ cm 2
ASTM D638 200
Unaged Tensile strength, psi, min. 1600
Elongation % ASTM D638 550
Elongation at rupture, %, min. 275
Oven Aging @ 135°C , 7 days
Tensile Stress at 200% elongation,
psi, min. at room temperature 1000 Tensile Strength Retention % ASTM D638 > 90
Modulus, psi, min. @ 130°C 300 Elongation Retention % ASTM D638 > 90
After Air Oven Aging at 121°C for 7 days (168 hours) Hot/Set @ 200°C, 20N/cm2 IEC-60811-2-1
Tensile stress, % of unaged value, min. 90
Hot Elongation % < 100
Elongation at rupture, % of unaged
value, min. 90 Permanent Set % <5
Hot Creep Test at 150°C Cure Behavior @ 180°C (MDR) HCY-I-24196
Elongation, %, max. 25
Ts1 minute >1
Set, %, max. 5
Heat Distortion after 1 hour in air oven at 121°C Tc90 minute <5
Percent max. 8.5 Mh-MI lb・in > 4.5
Ozone Resistance Moisture ppm HCY-I-24205 < 200
0.030% Concentration, 25°C, 24 hours No Cracks
No Cracks 0.0005% Concentration,
ELECTRICAL PROPERTIES UNIT TEST METHOD VALUE
52°C, 24 hours No Cracks
Cold Bend -55°C No Cracks Dielectric Constant @ 1 MHz - ASTM D150 < 2.3
Heat Deformation Test per ASTM D2220 Dissipation Factor @ 1 MHz - ASTM D150 < 0.0005
% Max. Distortion of buffed samples
Dielectric Strength kV/mm ASTM D149 > 20
of insulation conditioned for 5 minutes
and under load for 15 minutes No Cracks DC Volume Resistivity ohm cm ASTM D257 > 1016

TREE RESISTANCE UNIT TEST METHOD VALUE


Relative Bow-tie Tree Size % Internal < 15
Resistance to Water Tree
Growth @25°C, 30 days % Internal < 0.1
1. Tree test conditions: Frequency=1kHz, Applied Voltage=5kV, 0.01M NaCl So-
lution.
2. Values are typical : not to be construed for specification.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. 0
Copyright © 2018, American Wire Group, Inc. 20170208
NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Allowable Ampacities of Insulated Conductors

Allowable Ampacities of Insulated Aluminum or CopperClad Allowable Ampacities of Insulated Copper Conductors
Aluminum Conductors
• Rated Up to and Including 2000 • Rated Up to and Including 2000
Volts, 60°C through 90°C (140°F Volts, 60°C through 90°C (140°F
through 194°F). through 194°F).
• Not More Than Three Current- • Not More Than Three Current-
Carrying Conductors in Race- Carrying Conductors in Race-
way, Cable, or Earth (Directly way, Cable, or Earth (Directly
Buried). Buried).
• Based on Ambient Temperature • Based on Ambient Temperature
of 30°C (86°F) of 30°C (86°F).
. .

Conductor 60°C/140°F 75°C/167°F 90°C/194°F Conductor 60°C/140°F 75°C/167°F 90°C/194°F


]
Size TW, UF RHW, THHW, TBS, SA, SIS, FEP, FEPB, Size TW, UF RHW, THHW, TBS, SA, SIS, FEP, FEPB,
(AWG/kcmil) THW, THWN, MI, RHH, RHW-2, THHN, (AWG/kcmil) THW, THWN, MI, RHH, RHW-2, THHN,
XHHW, USE, ZW XHH, XHHW, XHHW-S, XHHW, USE, ZW XHH, XHHW, XHHW-S,
USE-2, ZW USE-2, ZW
18 - - - 18 - -
16 - - - 16 - -
14* - - - 14* 15 20 25
12* 15 20 25 12* 20 25 30
10* 25 30 35 10* 30 35 40
8 35 40 45 8 40 50 55
6 40 50 55 6 55 65 75
4 55 65 75 4 70 85 95
3 65 75 85 3 85 100 115
2 75 90 100 2 95 115 130
1 85 100 115 1 110 130 145
1/0 100 120 135 1/0 125 150 170
2/0 115 135 150 2/0 145 175 195
3/0 130 155 175 3/0 165 200 225
4/0 150 180 205 4/0 195 230 260
250 170 205 230 250 215 255 290
300 195 230 260 300 240 285 320
350 210 250 280 350 260 310 350
400 225 270 305 400 280 335 380
500 260 310 350 500 320 380 430
600 285 340 385 600 350 420 475
700 315 375 425 700 385 460 520
750 320 385 435 750 400 475 535
800 330 395 445 800 410 490 555
900 355 425 480 900 435 520 585
1000 375 445 500 1000 455 545 615
* Small Conductors. Unless specifically permitted in 240.4(E) through (G), * Small Conductors. Unless specifically permitted in 240.4(E) through (G),
the overcurrent protection shall not exceed 15 amperes for 14 AWG, 20 am- the overcurrent protection shall not exceed 15 amperes for 14 AWG, 20 am-
peres for 12 AWG, and 30 amperes for 10 AWG copper; or 15 amperes for 12 peres for 12 AWG, and 30 amperes for 10 AWG copper; or 15 amperes for 12
AWG and 25 amperes for 10 AWG aluminum and copper-clad aluminum after AWG and 25 amperes for 10 AWG aluminum and copper-clad aluminum
any correction factors for ambient temperature and number of conductors after any correction factors for ambient temperature and number of conduc-
have been applied. tors have been applied.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. N
Copyright © 2018, American Wire Group, Inc. 20170208
NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Thermal Resistivities of Materials

Material Thermal Resistivity (ρT)


Km/W
Insulating Materials*
Paper insulation in solid type cables 6.0
Paper insulation in oil-filled cables 5.0
Paper insulation in cables with external gas pressure 5.5
Paper insulation in cables with internal gas pressure
A) Pre-impregnated 5.5
B) Mass-impregnated 6.0
PE 3.5
XLPE 3.5
PPL 5.5
Polyvinyl chloride
Up to and including 3kV cables 5.0
Greater than 3kV cables 6.0
EPR
Up to and including 3kV cables 3.5
Greater than 3kV cables 5.0
Butyl rubber 5.0
Rubber 5.0
Protective Coverings
Compounded jute and fibrous materials 6.0
Rubber sandwich protection 6.0
Polychoroprene
PVC
Up to and including 35kV cables 5.0
Greater than 35kV cables 6.0
PVC/Bitumen on corrugated aluminum sheaths 6.0
PE 3.5
Materials for Duct Installations
Concrete 1.0
Fibre 4.8
Earthenware 1.2
PVC 6.0
PE 3.5
*For the purposes of current rating calculations, the semiconducting screening materials are assumed to have the
same thermal properties as the adjacent dielectric materials.
Where plastic or elastomeric materials are used for protective coverings, the thermal resistivities shall be taken to be
the same as those for the insulation grades of the materials given in this table.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. M
Copyright © 2018, American Wire Group, Inc. 20160322
NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
PowerGuard®
Testing Recommendations

June 7, 2016
Regarding field testing cables for commissioning, we recommend the VLF Testing in Accordance to
IEEE 400: IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Sys-
tems in accordance to Table 1 IEEE400.2 VLF Test Voltage Levels for Sinusoidal, Cosine-Rectangular.
Voltage Peak values are shown in brackets for Cosine-Rectangular and Squarewave.
The most important application part of the new IEEE400.2 cable testing guide is the Table 1 below
that shows the recommended VLF Hipot voltage testing levels for the various medium voltage cable
ratings for both new (Acceptance and Installation Testing) and old (Maintenance Testing) cable in-
stallations.
This is a Pass/Fail type test, the cable either withstands the specified test voltage or it does not.
The IEEE400 defines types of field tests:
Installation Test
This test is conducted after the installation of the cable but before the installation ofaccessories like
the splices and terminations. Its purpose is to detect any transport, manufacturing, storage or instal-
lation defects.
Acceptance Test
This test is performed after the installation of the accessories, but before energization ofthe cable. It
checks for installation defects of the complete cable system, as well as defects as a result of ship-
ping, manufacturing or storage.
Test Frequency
VLF test frequency is 0.1Hz of a testing of 30 minutes.

Cable Rating Installation Test Acceptance Test Maintenance Test


phase to phase phase to ground phase to ground phase to ground
(RMS)
kV rms kV rms (or peak) kV rms (or peak) kV rms (or peak)
5 9 (13) 10 (14) 7 (10)
8 11 (16) 13 (18) 10 (14)
15 18 (25) 20 (28) 16 (22)
25 27 (38) 31 (44) 23 (33)
35 39 (55) 44 (62) 33 (47)

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. 321
Copyright © 2018, American Wire Group, Inc. 20170306
NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Wire & Cable
Methods of Color Coding

Used to identify conductors for point-to-point wiring and for circuit diagrams. Color codes are used to establish a standard for use by dif-
ferent manufacturers.
The first color code used colored tracers in a solid colored braid. Most control cable color codes are adaptations of this method. Later, for
ease and convenience, ink printed versions were developed.
Telephone requirements established special color codes.

Color Codes (ICEA Methods)


ICEA/NEMA Method 1 ICEA/NEMA Method 5
Colored insulation with contrasting ink tracers as required. Six A color coding using braids. Also sometimes specified using
different insulation colors and four different colored ink trac- colored insulation and contrasting tracers as an extension of
ers are used to provide positive identification through 21 con- Method I to eliminate duplicate conductors. Up to 127 positive
ductors. The same identification sequence is repeated for conductor coding are available with this method. Usually
cables containing more than 21 conductors. specified as per: ICEA5-61-402 Table 5-1 or ICEA 5-19-81 Table
ICEA/NEMA Method 2 5-2.
A neutral colored compound is used with single or double spi- ICEA/NEMA Method 6
ral ink tracers as required to provide positive identification A color coding whereby one conductor in each layer is identi-
through 21 conductors. The identification sequence is repeated fied by a braid, tape, ridge, stripe or color.
for cables containing more than 21 conductors. ICEA/NEMA Paired Color Code
ICEA/NEMA Method 3 A coding whereby one leg of all pairs is coded white and its
A neutral or single colored insulation compound is surface ink mate is coded in accordance with the first 21 conductors of
printed with both conductor number and color designation to Method 1, omitting white and repeating the sequence as nec-
provide positive identification through 21 conductors. The essary.
identification sequence is repeated for colors containing more Telephone Paired Color Code
than 21 conductors. Five colors are paired with each of five mate colors to give 25
ICEA/NEMA Method 4 identified pairs. The color sequences are repeated for more
A neutral or single colored insulation compound is surface ink than 25 pairs using colored binder strings for group identifica-
printed with conductor number to provide positive conductor tion.
identification through 21 conductors. The identification se-
quence is repeated for cables containing more than 21 con-
ductors.
Note: UL and the NEC restrict the use of green and white as colors and stripes. Special color codes are available to meet these requirements. One method is
ICEA Method E-2 which is similar to Method 1 and ICEA Method E-4 which is similar to Method 2.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. B
Copyright © 2018, American Wire Group, Inc. 20140110
Wire & Cable
Color Coding Charts

ICEA Method 1, Table E-1 ICEA Method 1, Table E-2


(Colored compound with tracers) (Colored compound with tracers)

Conductor Background Tracer Conductor Background Tracer


Number or Base Color Color Number or Base Color Color
1* Black – 1* Black –
2 White – 2 Red –
3 Red – 3 Blue –
4 Green – 4 Orange –
5 Orange – 5 Yellow –
6 Blue – 6 Brown –
7 White Black 7 Red Black
ICEA Method 2, Table E-1 8 Blue Black
8 Red Black
(Neutral colored compound with tracers)
9 Green Black 9 Orange Black
10 Orange Black Conductor First Second 10 Yellow Black
11 Blue Black Number Tracer Tracer 11 Brown Black
12 Black White Color Color 12 Black Red
13 Red White (Wide (Narrow 13 Blue Red
Tracer) Tracer)
14 Green White 14 Orange Red
1* Black –
15 Blue White 15 Yellow Red
2 White –
16 Black Red 16 Brown Red
3 Red –
17 White Red 17 Black Blue
4 Green –
18 Orange Red 18 Red Blue
5 Orange –
19 Blue Red 19 Orange Blue
6 Blue –
20 Red Green 20 Yellow Blue
7 White Black
21 Orange Green 21 Brown Blue
8 Red Black
*This conductor is in the inside of the assembly. 22 Black Orange
9 Green Black
23 Red Orange
10 Orange Black
24 Blue Orange
11 Blue Black
25 Yellow Orange
12 Black White
26 Brown Orange
13 Red White
27 Black Yellow
14 Green White
28 Red Yellow
15 Blue White
29 Blue Yellow
16 Black Red
30 Orange Yellow
17 White Red
31 Brown Yellow
18 Orange Red
32 Black Brown
19 Blue Red
33 Red Brown
20 Red Green
34 Blue Brown
21 Orange Green
35 Orange Brown
*This conductor is in the inside of the assembly.
36 Yellow Brown
*This conductor is in the inside of the assembly.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
B Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Wire & Cable
Color Coding Charts

ICEA Method 1, Table E-2 ICEA Method 3 ICEA Method 4


(Neutral colored compound with tracers) (Neutral or single color compound with surface (Neutral or single color compound with surface
printing of numbers and color designations) printing of numbers)
Conductor Background Tracer
Number or Base Color Color Conductor Printed Legend Conductor Printed Legend
1* Black - Number Number
2 Red - 1* 1 – Black 1* 1
3 Blue - 2 2 – White 2 2
4 Orange - 3 3 – Red 3 3
5 Yellow - 4 4 – Green 4 4
6 Brown - 5 5 – Orange 5 5
7 Red Black 6 6 – Blue 6 6
8 Blue Black 7 7 – White–Black 7 7
9 Orange Black 8 8 – Red–Black 8 8
10 Yellow Black 9 9 – Green–Black 9 9
11 Brown Black 10 10 – Orange–Black 10 10
12 Black Red 11 11 – Blue–Black 11 11
13 Blue Red 12 12 – Black–White 12 12
14 Orange Red 13 13 – Red–White 13 13
15 Yellow Red 14 14 – Green–White 14 14
16 Brown Red 15 15 – Blue–White 15 15
17 Black Blue 16 16 – Black–Red 16 16
18 Red Blue 17 17 – White–Red 17 17
19 Orange Blue 18 18 – Orange–Red 18 18
20 Yellow Blue 19 19 – Blue–Red 19 19
21 Brown Blue 20 20 – Red–Green 20 20
22 Black Orange 21 21 – Orange–Green 21 21
*This conductor is in the inside of the assembly. *This conductor is in the inside of the assembly.
23 Red Orange
24 Blue Orange
25 Yellow Orange
26 Brown Orange
27 Black Yellow
28 Red Yellow
29 Blue Yellow
30 Orange Yellow
31 Brown Yellow
32 Black Brown
33 Red Brown
34 Blue Brown
35 Orange Brown
36 Yellow Brown
*This conductor is in the inside of the assembly.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. B
Copyright © 2018, American Wire Group, Inc. 20140110
Wire & Cable
Color Coding Charts

ICEA Method 5
(Colored compounds with tracers)

Cond. Background First Second Cond. Background First Second Cond. Background First Second
Number or Tracer Tracer Number or Tracer Tracer Number or Tracer Tracer
Base Color Color Color Base Color Color Color Base Color Color Color
1* Black – – 44 Black White Blue 87 Black Orange –
2 White – 45 White Black Blue 88 White Orange –
3 Red – – 46 Red White Blue 89 Red Orange –
4 Green – – 47 Green Orange Red 90 Green Orange –
5 Orange – – 48 Orange Red Blue 91 Blue Orange –
6 Blue – – 49 Blue Red Orange 92 Black Blue –
7 White Black – 50 Black Orange Red 93 White Blue –
8 Red Black – 51 White Black Orange 94 Red Blue –
9 Green Black – 52 Red Orange Black 95 Green Blue –
10 Orange Black – 53 Green Red Blue 96 Orange Blue –
11 Blue Black – 54 Orange Black Blue 97 Yellow – –
12 Black White – 55 Blue Black Orange 98 Yellow Black –
13 Red White – 56 Black Orange Green 99 Yellow White –
14 Green White – 57 White Orange Green 100 Yellow Red –
15 Blue White – 58 Red Orange Green 101 Yellow Green –
16 Black Red – 59 Green Black Blue 102 Yellow Orange –
17 White Red – 60 Orange Green Blue 103 Yellow Blue –
18 Orange Red – 61 Blue Green Orange 104 Black Yellow –
19 Blue Red – 62 Black Red Blue 105 White Yellow –
20 Red Green – 63 White Orange Blue 106 Red Yellow –
21 Orange Green – 64 Red Black Blue 107 Green Yellow –
22 Black White Red 65 Green Orange Blue 108 Orange Yellow –
23 White Black Red 66 Orange White Red 109 Blue Yellow –
24 Orange Black White 67 Blue White Red 110 Black Yellow Red
25 Blue Black White 68 Black Green Blue 111 White Yellow Red
26 Red Black White 69 White Green Blue 112 Green Yellow Red
27 Orange Black White 70 Red Green Blue 113 Orange Yellow Red
28 Black Red Green 71 Green White Red 114 Blue Yellow Red
29 White Red Green 72 Orange Red Black 115 Black Yellow White
30 Red Black Green 73 Blue Red Black 116 Red Yellow White
31 Green Black Orange 74 Black Orange Blue 117 Green Yellow White
32 Orange Black Green 75 Red Orange Blue 118 Orange Yellow White
33 Blue White Orange 76 Green Red Black 119 Blue Yellow White
34 Black White Orange 77 Orange White Green 120 Black Yellow Green
35 White Red Orange 78 Blue White Green 121 White Yellow Green
36 Orange White Blue 79 Red White Orange 122 Red Yellow Green
37 White Red Blue 80 Green White Orange 123 Orange Yellow Green
38 Black White Green 81 Blue Black Green 124 Blue Yellow Green
39 White Black Green 82 Orange White – 125 Black Yellow Blue
40 Red White Green 83 Green Red – 126 White Yellow Blue
41 Green White Blue 84 Black Green – 127 Red Yellow Blue
42 Orange Red Green 85 White Green – *This conductor is in the inside of the assembly.
43 Blue Red Green 86 Blue Green –

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
B Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Recommended Reel Handling Practices
How to Handle Cable Reels

Cradle both reel flanges between Upended heavy reels will often arrive
forks. damaged. Refuse or receive subject
to inspection for hidden damage.

Reels can be hoisted with a shaft Do not lift by top flange. Cable
extending through both flanges. or reel will be damaged.

Lower reels from truck using Never allow forks to touch


hydraulic gate, hoist or fork lift. cable surface or reel wrap.
LOWER CAREFULLY!

Always load with flanges on Never drop reels.


edge and chock and block
securely.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. C
Copyright © 2018, American Wire Group, Inc. 20170123
NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Steel Reel Specifications

I-Beam Tire Fluted Steel Reel—Type RMT


NOTE — When required, cable test hole in the flange shall not have more than 3 flutes removed to provide this opening. The cable test hole shall be rein-
forced along the cutout with a metal equal to or greater than that required for use in the drum of the reel. Height of cable test hole to be no greater than one-
half the length.

30°
TRAVERSE

Y”

1” RADIUS

LAG OPENING

FLANGE THE LAG OPENING SHOULD


DIAMETER DRUM BE WELL ROUNDED AND
DIAMETER GROUND SMOOTH

TIRE

DRUM
HEAD SHEET

INNER RING
ARBOR HOLE

FLUTES LONG CROSS ARM


SHORT CROSS ARM

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. D
Copyright © 2018, American Wire Group, Inc. 20140110
Steel Reel Specifications

General Purpose Steel Fluted Returnable Reels for Wire and Cables—Class 1

Type* –Reel Dimensions– Max. Arbor Max. Tire –––––Cross Arms––––– Drum Inner (Flange) Maximum
Fl Trav Drum Overall Hole Number Size U.S.S. Long Short U.S.S. Ring Head –––Capacity–––
Width Diameter Flutes (in) (ga) (in) (in) (ga) Dimensions Sheet (lb) (kg)
(in) (in) per Hd (in) U.S.S.
(ga)
RM 42 24 24 33 3.25 24 2x5/16 8 5x2 4x2 12 3-3/4x3/16 16 1,956 887
RM 48 24 24 33 3.25 24 2x5/16 8 5x2 4x2 12 3-3/4x3/16 16 3,072 1,393
RM 54 32 32 41 3.25 30 2x5/16 8 5x2 4x2 12 3-3/4x3/16 16 4,464 2,024
RM 60 32 32 41 3.25 30 2x5/16 8 5x2 4x2 12 3-3/4x3/16 16 6,360 2,884
RM 66 32 36 41 3.25 32 2-1/2x1/2 8 6x2 5x2 12 3-3/4x3/16 16 7,680 3,482
RM 72 36 40 45 3.25 40 2-1/2x1/2 8 6x2 5x2 12 3-3/4x1/4 16 10,260 4,654
RM 72 36 48 45 3.25 40 2-1/2x1/2 8 6x2 5x2 12 3-3/4x1/4 16 7,872 3,570
RM 78 36 48 45 3.25 40 2-1/2x5/8† 8 6x2 5x2 12 3-3/4x1/4 16 10,752 4,876
RMT 84 36 42 45 5.25 40 7.5lb/ft, 3" I-Beam 8 7-7/8x2 6x2 10 4x1/4 16 13,608 6,171
RMT 84 45 42 55 5.25 40 7.5lb/ft, 3" I-Beam 8 7-7/8x2 6x2 10 4x1/4 16 17,004 7,711
RMT 84 45 56 55 5.25 40 7.5lb/ft, 3" I-Beam 8 7-7/8x2 6x2 10 4x1/4 16 11,196 5,050
RMT 90 45 42 55 5.25 40 7.5lb/ft, 3" I-Beam 8 7-7/8x2 6x2 10 4-1/4x1/4 16 21,036 9,540
RMT 90 45 56 55 5.25 40 7.5lb/ft, 3" I-Beam 8 7-7/8x2 6x2 10 4-1/4x1/4 16 15,216 6,900
RMT 90 54 56 64 5.25 40 7.5lb/ft, 3" I-Beam 8 7-7/8x2 6x2 8 4-1/4x1/4 16 18,252 8,277
RMT 96 60 42 71 5.25 40 7.5lb/ft, 3" I-Beam 8 7-7/8x3 6x3 8 4-1/2x5/16 14 26,000 11,719
RMT 98 60 56 71 5.25 40 7.5lb/ft, 3" I-Beam 8 7-7/8x3 6x3 8 4-1/2x5/16 14 26,000 11,719
RMT** 108 74 56 85 5.25 40 7.5lb/ft, 3" I-Beam 8 7-7/8x3 6x3 8 4-1/2x5/16 14 30,000 13,605
* RM—Flat bar tire
** Generally used for aluminum wire and cable
† Alternate size is 3x1/2 inch
RMT—I-Beam Tire
NOTE—Tie holes, if necessary, shall be in the flat portion of the head sheet. There will be no holes in the flute itself.
NOTE—A range of 3 to 3.25-inch and 5 to 5.25-inch arbor hole diameter shall be permitted for existing reels until the year 2005.

Welding Requirements for Class 1 Reels


Head sheet to tire—at all radii of flute-intermittent weld
Head sheet to inner ring—at all radii of flute-intermittent weld
Drum to inner ring—intermittent weld
Cross arm to cross arm—continuous weld
Cross arm to inner ring—continuous weld
Cross arm to hub—continuous weld
Back-up plate to hub and cross arm—continuous weld
Port frame—continuous weld
All welds shall reflect good welding practice with proper penetration.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
D Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Cabling

Cable A 1500' linear

Cable B 1500' linear A 1500' linear

B 1500' linear

C 1500' linear

4500' linear
Cable C 1500' linear

4500' linear

Cabled (Triplexed) Cables


Cable A 1500' linear

Cable B 1500' linear

CKT 1350' linear


Cable C 1500' linear

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. I
Copyright © 2018, American Wire Group, Inc. 20140506
NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Metric Size to AWG Size

Area Size Nominal Nominal Number Area Size Nominal Nominal Number
(mm2) AWG/MCM Overall Overall of Wires (mm2) AWG/MCM Overall Overall of Wires
Diameter Diameter Diameter Diameter
(mm) (in) (mm) (in)
1010 2000 41.45 1.632 127 42.41 1 8.43 0.332 19
1000 41.14 1.620 91 35 7.65 0.302 19
887 1750 38.76 1.526 127 35 7.56 0.298 7
800 36.81 1.448 61 33.62 2 7.42 0.292 7
760 1500 35.87 1.412 91 26.67 3 6.61 0.260 7
633 1250 32.74 1.289 91 25 6.39 0.252 7
507 1000 29.26 1.152 61 21.15 4 5.89 0.232 7
500 29.05 1.143 37 16 5.13 0.202 7
400 25.97 1.023 37 13.30 6 4.67 0.184 7
380 750 25.35 0.998 61 10 4.05 0.160 7
304 600 22.68 0.893 61 8.37 8 3.71 0.146 7
300 22.46 0.884 37 6.0 3.12 0.123 7
253.4 500 20.65 0.813 37 5.26 10 2.95 0.116 7
240 20.09 0.792 37 4.0 2.55 0.101 7
203 400 18.49 0.728 37 3.31 12 2.34 0.092 7
185 17.64 0.695 37 2.5 2.01 0.080 7
177 350 17.30 0.681 37 2.08 14 1.85 0.073 7
152 300 16.00 0.630 37 1.5 1.56 0.062 7
150 15.85 0.624 19 1.31 16 1.47 0.058 7
127 250 14.61 0.575 37 1.0 1.29 0.051 7
120 14.15 0.558 19 0.82 18 1.02 0.046 7
107.2 4/0 13.41 0.528 19 0.75 0.98 0.039 7
95 12.60 0.497 19 0.52 20 0.81 0.032 7
85.01 3/0 11.94 0.470 19 0.50 0.80 0.031 7
70 10.86 0.427 19 0.33 22 0.64 0.025 7
67.43 2/0 10.64 0.419 19 0.25 0.56 0.022 7
53.49 1/0 9.47 0.373 19 0.20 24 0.51 0.020 7
50 9.15 0.361 19

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. E
Copyright © 2018, American Wire Group, Inc. 20140110
NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Copper Conductor Stranding Chart
Class A thru M

Size Approx. Pounds Concentric Concentric Concentric Concentric Rope Rope Rope
AWG O.D. per Strand Strand Strand Strand Lay Lay Lay
1000 ft Class A Class B Class C Class D Concentric Concentric Bunch
Strand Strand Strand
Class G Class H Class I
24AWG
(.201")
36 0.0050 0.07570 N/A N/A N/A N/A N/A N/A N/A
35 0.0056 0.09540 N/A N/A N/A N/A N/A N/A N/A
34 0.0063 0.12030 N/A N/A N/A N/A N/A N/A N/A
33 0.0071 0.15170 N/A N/A N/A N/A N/A N/A N/A
32 0.0080 0.19130 N/A N/A N/A N/A N/A N/A N/A
30 0.0089 0.24130 N/A N/A N/A N/A N/A N/A N/A
30 0.0100 0.30420 N/A N/A N/A N/A N/A N/A N/A
29 0.0113 0.38360 N/A N/A N/A N/A N/A N/A N/A
28 0.0126 0.48370 N/A N/A N/A N/A N/A N/A N/A
27 0.0142 0.61000 N/A N/A N/A N/A N/A N/A N/A
26 0.0159 0.76920 N/A N/A N/A N/A N/A N/A N/A
25 0.0179 0.96990 N/A N/A N/A N/A N/A N/A N/A
24 0.0201 1.22300 N/A N/A N/A N/A N/A N/A N/A
23 0.0226 1.54200 N/A N/A N/A N/A N/A N/A N/A
22 0.0254 1.94500 N/A N/A N/A N/A N/A N/A N/A
21 0.0285 2.45200 N/A N/A N/A N/A N/A N/A N/A
20 0.0363 3.15400 N/A 7 19 N/A N/A N/A N/A
18 0.0456 5.01500 N/A 7 19 N/A N/A N/A N/A
16 0.0576 7.97400 N/A 7 19 N/A N/A N/A N/A
14 0.0726 12.68000 N/A 7 19 37 49 N/A N/A
12 0.0915 20.16000 N/A 7 19 37 49 N/A N/A
10 0.1160 32.06000 N/A 7 19 37 49 N/A 26
9 0.1600 40.42000 N/A 7 19 37 49 133 N/A
8 0.1460 51 N/A 7 19 37 49 133 41
6 0.1840 80.9 N/A 7 19 37 49 133 63
4 0.2320 129 7 7 19 37 49 133 105
3 0.2600 162 7 7 19 37 49 133 N/A
2 0.2990 205 7 7 19 37 49 133 161
1 0.3320 259 7 19 37 61 133 259 210
1/0 0.3730 326 7 19 37 61 133 259 266
2/0 0.4190 411 7 19 37 61 133 259 342
3/0 0.4700 518 7 19 37 61 133 259 418
4/0 0.5280 653 7 19 37 61 133 259 532
250000 0.5750 772 19 37 61 91 259 427 637
300000 0.6300 925 19 37 61 91 259 427 735
350000 0.6810 1080 19 37 61 91 259 427 882
400000 0.7280 1236 19 37 61 91 259 427 980
500000 0.8130 1542 37 37 61 91 259 427 1225
600000 0.8930 1850 37 61 91 127 427 703 1470
750000 0.9980 2316 61 61 91 127 427 703 1862
1000000 1.1520 3086 61 61 91 127 427 703 2527

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. G
Copyright © 2018, American Wire Group, Inc. 20170303
NOTES

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Wire & Cable
Glossary of Terms

AWG Color Code


Abbreviation for American Wire Gauge. A system for circuit identification through use of solid colors
AWM and contrasting tracers.
Designation for appliance wiring material. Compound
Alternating Current An insulating or jacketing material made by mixing two or
Electric current that continually reverses its direction. Is ex- more ingredients.
pressed in cycles per second (hertz or Hz). Concentricity
Ambient Temperature In a wire or cable, the measurement of the location of the cen-
The temperature of the medium (gas, liquid or earth) sur- ter of the conductor with respect to the geometric center of
rounding an object. the surrounding insulation.
American Mustang Conductor
A premium grade thermoset cord, UL listed as SOOW or An uninsulated wire suitable for carrying electrical current.
SJOOW, CSA SOOW and SJOOW. Contacts
American Wire Gauge (AWG) The parts of the connector that actually carry the electrical cur-
A standard system for designating wire diameter. Also re- rent and that touch the equivalent parts in the mating connec-
ferred to as the Brown and Sharpe (B&S) wire gauge. tor.
Ampacity Continuity Check
See Current Carrying Capacity. A test to determine whether electrical current flows continu-
Ampere ously throughout the length of a single wire or individual
The unit of current. One ampere is the current flowing through wires in a cable.
one ohm of resistance at one volt potential. Cord
Anneal A flexible insulated wire suitable for carrying electric current.
Relief of mechanical stress through application of heat and Corona
gradual cooling. Annealing copper renders it soft and less brit- Ionization of air surrounding a conductor caused by the influ-
tle. ence of high voltage. Causes deterioration of insulation mate-
Audio Frequency rials.
The range of frequencies audible to the human ear. Usually Crazing
20–20,000 Hz. The minute cracks on the surface of plastic materials.
Braid CSA
A fibrous or metallic group of filaments interwoven in cylindri- Abbreviation for Canadian Standards Association, a nonprofit,
cal form to form a covering over one or more wires. independent organization that operates a listing service for
Breakdown Voltage electrical and electronic materials and equipment. The Cana-
The voltage at which the insulation between two conductors dian counterpart of the Underwriters Laboratories
breaks down. Current Carrying Capacity
Bunch Stranding The maximum current an insulated conductor can safely carry
A group of wires of the same diameter twisted together with- without exceeding its insulation and jacket temperature limita-
out a predetermined pattern. tions. It is dependent on the installation conditions.
Cabling Decibel (db)
The twisting together of two or more insulated conductors to A unit that expresses differences of power or voltage level. It
form a cable. is used to express power loss in passive circuits or cables.
Capacitance Dielectric Strength
The ability of a dielectric material between conductors to store The voltage that an insulation can withstand before break-
electricity when a difference of potential exists between the down occurs. Usually expressed as a voltage gradient (such as
conductors. The unit of measurement is the farad, which is the volts per mil).
capacitance value that will store a charge of one coulomb Direct Capacitance
when a one-volt potential difference exists between the con- The capacitance measured directly from conductor to conduc-
ductors. In AC, one farad is the capacitance value that will per- tor through a single insulating layer.
mit one ampere of current when the voltage across the Drain Wire
capacitor changes at a rate of one volt per second. In a cable, the uninsulated wire laid over the shield compo-
Circuit (Electric) nent or components and used as a ground connection.
The complete path of an electrical current. When the continu- Drawing
ity is broken, it is called an open circuit; when continuity is In wire manufacture, pulling the metal through a die or series
maintained, it is called a closed circuit. of dies to reduce diameter to a specified size.
Cold Flow
Permanent deformation of the insulation due to mechanical
force or pressure (not due to heat softening).

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. F
Copyright © 2018, American Wire Group, Inc. 20140110
Wire & Cable
Glossary of Terms

Eccentricity Hz
Like concentricity, a measure of the center of a conductor's lo- Abbreviation for hertz.
cation with respect to the circular cross section of the insula- Impedance
tion. Expressed as a percentage of displacement of one circle The total opposition that a circuit offers to the flow of alternat-
within the other. ing current or any other varying current at a particular fre-
Elongation quency. It is a combination of resistance R and reactance X,
The fractional increase in length of a material stressed in ten- measured in ohms.
sion. Inductance
EMI The property of a circuit or circuit element that opposes a
Abbreviation for electromagnetic interference. change in current flow, thus causing current changes to lag be-
Farad hind voltage changes. It is measured in henrys.
A unit of electrical capacitance. Insulation
Filler A material having high resistance to the flow of electric cur-
1) A material used in multiconductor cables to occupy large in- rent. Often called a dielectric in radio frequency cable.
terstices formed by the assembled conductors; Jacket
2) An inert substance added to a compound to improve prop- An outer non-metallic protective covering applied over an in-
erties or decrease cost. sulated wire or cable.
Flame Resistance Jumper Cable
The ability of a material to resist the propagation of flame A short flat cable interconnecting two wiring boards or de-
once the heat source is removed. vices.
Flex Life Lay
The measurement of the ability of a conductor or cable to The length measured along the axis of a wire or cable re-
withstand repeated bending. quired for a single strand (in stranded wire) or conductor (in
Frequency cable) to make one complete turn about the axis of the con-
The number of times an alternating current repeats its cycle in ductor or cable.
one second. Longitudinal Shield
G A tape shield, flat or corrugated, applied longitudinally with
An industry designation for a 2kV portable power cable con- the axis of the core being shielded.
sisting of 2 4 insulated conductors with ground wires placed MTW
in the valleys for use in mines and similar applications. Thermoplastic insulated machine tool wire.
Gauge Multiconductor
A term used to denote the physical size of a wire. More than one conductor within a single cable complex.
G-GC designation Mylar
An industry for a 2kV portable power cable consisting of 3 in- A synthetic compound with high dielectric qualities made by
sulated conductors with 2 ground wires, and a ground check DuPont and used extensively in the wire and cable industry in
conductor. For use in mines and similar applications. tape form.
Ground NEMA
An electrical term meaning to connect to the earth or other Abbreviation for National Electrical Manufacturers Associa-
large conducting body to serve as an earth, thus making a tion.
complete electrical circuit. Ohm
Harness A unit of electrical resistance.
An arrangement of wires and cables, usually with many break- OSHA
outs, which have been tied together or pulled into a rubber or Abbreviation for Occupational Safety and Health Act, specifi-
plastic sheath, used to interconnect an electric circuit. cally the Williams Steiger Law passed in 1970 covering all fac-
Hertz (Hz) tors relating to safety in places of employment.
A term replacing cycles per second as an indication of fre- Plasticizer
quency. A chemical agent added to plastics to make them softer and
Hi-Pot more pliable.
A test designed to determine the highest voltage that can be Potting
applied to a conductor without breaking through the insula- The sealing of a cable termination or other component with a
tion. liquid that cures into an elastomer.
HPD Primary Insulation
Heater cord with thermoset insulation and cotton or rayon The first layer of nonconductive material applied over a con-
braid overall. ductor, whose prime function is to act as electrical insulation.
HPN
Parallel heater cord.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
F Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.
Wire & Cable
Glossary of Terms

Put-Up SJEOW
Packaging of finished wire or cable by size and length. Same construction as SEOW except 300 volt rated.
PVC SJO
Abbreviation for polyvinylchloride. Same as SJ, but oil resistant outer jacket. Can also be made
Rated Voltage “water resistant.” 300V, 60°C, 75°C, 900°C or 105°C.
The maximum voltage at which an electrical component can SJOOW
operate for extended periods without undue degradation or Same as SOOW except 300 volt rated.
safety hazard. SJT
REA Junior hard service thermoplastic conductors with overall
Abbreviation for Rural Electrification Administration, which is thermoplastic jacket, 300V, 60°C, 75°C, 900C or 105°C.
part of the US Dept. of Agriculture. REA establishes specifica- SJTO
tions and provides approval for telephone station wire and Same as SJT, but oil resistant thermoplastic outer jacket.
power cables. SLC
Resistance Stage Lighting Cable. A 600-volt single conductor cable for
A measure of the difficulty in moving electrical current use with indoor and outdoor stages, fairs and carnivals.
through a medium when voltage is applied. It is measured in SO
ohms. Hard service cord. Same construction as type S, except oil re-
RFI sistant thermoset jacket. 600V, 600°C to 105°C.
Abbreviation for radio frequency interference. SOOW
S Same as SOW except oil resistant insulation.
Heavy duty, rubber insulated portable cord. Standard copper SOW
conductors with separator and individual rubber insulation. Same as SO except suitable for outdoor use.
Two or more color-coded conductors cabled with filler,
wrapped with separator and rubber jacketed overall 600V. SP-1
All rubber, parallel jacketed, two conductor light duty cord for
SEO pendant or portable use. 300V.
Same construction as STO, except insulation and jacket are
made of Thermoplastic Elastomer Rubber (TPE) 600V. SP-2
Same as SP-1, but heavier construction, with or without third
SEOOW conductor for grounding purposes. 300V.
Same construction as SEOW, except with oil resistant insula-
tion. SP-3
Same as SP-2, but heavier construction for refrigerators or
SEOW room air conditioners. 300V.
Same construction as SEO, except suitable for outdoor use.
Usually UL listed for continuous submersion in water 600V. Spacing
Distance between the closest edges of two adjacent conduc-
Separator tors.
Pertaining to wire and cable, a layer of insulating material
such as textile paper, Mylar, etc., which is placed between a Spark Test
conductor and its dielectric, between a cable jacket and the A test designed to locate pinholes in the insulation of a wire or
components it covers, or between various components of cable by application of a voltage for a very short period of
multiple conductor cable. It can be utilized to improve strip- time while the wire is being drawn through a field of elec-
ping qualities and/or flexibility, or can offer additional mechan- trodes.
ical or electrical protection to the components it separates. SPE
Shield Same construction as SP-1, except insulation and jacket made
A tape shield, or braid of metal, usually copper, aluminum or of Thermoplastic Elastomer Rubber (TPE).
other conducting material, placed around or between electric Spiral Wrap
circuits or cables or their components to contain any un- The helical wrap of a tape or other material over a core or
wanted radiation, or to keep out an unwanted interference. component.
SJ SPT-1
Junior hard service rubber insulated pendant or portable cord. Same as SP-1, except all thermoplastic, 300V. With or without
Same construction as SJT, except insulation and jacket is ther- third conductor for grounding.
moset (rubber) 300V. SPT-2
SJE Same as SP-2, except all thermoplastic. 300V. With or without
Same construction as SJT, except insulation and jacket made third conductor for grounding.
of Thermoplastic Elastomer Rubber (TPE)300V. SPT-3
SJEO Same as SP-3, except all thermoplastic. 300V. With or without
Same construction as SJO, except insulation and jacket made third conductor for grounding.
of Thermoplastic Elastomer Rubber (TPE).

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
Information on this sheet subject to change without notice. F
Copyright © 2018, American Wire Group, Inc. 20140110
Wire & Cable
Glossary of Terms

ST Thermoset
Hard service cord, jacketed. Same as type S, except all plastic A material that hardens or sets when heat is applied and that,
construction. 600V, 600°C to 105°C. once set, cannot be resoftened by heating. The application of
STO heat cures or vulcanizes the material.
Same as ST, but with oil resistant thermoplastic outer jacket. TPE
600V, 600°C to 105°C. Abbreviation for Thermoplastic Elastomer.
Strand UL
A single uninsulated wire. Abbreviation for Underwriters Laboratories, a nonprofit inde-
Stranded Conductor pendent organization that operates a listing service for electri-
A conductor composed of wires or groups of wires twisted to- cal and electronic materials and equipment.
gether. Voltage
Surge The term most often used in place of electromotive force, po-
A temporary and relatively large increase in the voltage or cur- tential, potential difference or voltage drop to designate the
rent in an electric circuit or cable. Also called a transient. electrical pressure that exists between two points and is capa-
SV ble of producing a current when a closed circuit is connected
Vacuum cleaner cord, rubber insulated with rubber jacket, between two points.
rated at 300V. VW-1
SVE A flammability rating established by Underwriters Laborato-
Same construction as SV, except insulation and jacket made of ries for wires and cables that pass a specific vertical flame
Thermoplastic Elastomer (TPE). test, formerly designated FR-1.
SVT W (Type)
Same as SV, except all plastic construction. With or without An industry designation for a 2kV portable power cable con-
third conductor for grounding purposes only. 300V, 600°C to sisting of 1–6 insulated conductors. For use in mines and simi-
105°C. lar severe duty applications.
TC W
Tray Cable. Multi-conductor cable specifically approved for UL designation for outdoor listed flexible cord that is tested
use installed in cable trays. for sunlight and weather requirements (e.g., 5TW).
Tensile Strength Water Resistant
The pull stress required to break a given specimen. UL designation for cords that have an insulation on the indi-
vidual conductors that passes UL requirements (e.g., 5T Water
Thermoplastic Resistant or 5T Dry 105°C, Water Resistant 60°C).
A material that softens and melts when heated and becomes
firm on cooling.

www.buyawg.com
TOLL FREE 1.800.342.7215
Telephone 1.954.455.3050
Fax 1.954.455.9886
APPENDIX

sales@buyawg.com
F Information on this sheet subject to change without notice.
20140110 Copyright © 2018, American Wire Group, Inc.