Professional Documents
Culture Documents
CI51J
HIDRAULICA DE AGUAS SUBTERRANEAS
Y SU APROVECHAMIENTO
TEMA 7
HIDRAULICA DE CAPTACIONES VERTICALES
EJEMPLOS DE PRUEBAS DE BOMBEO
OTOÑO 2006
UNIVERSIDAD DE CHILE
FACULTAD DE CIENCIAS FÍSICAS Y MATEMÁTICAS
DEPARTAMENTO DE INGENIERIA CIVIL
CI51J
EJEMPLO 1
EJEMPLO 2
EJEMPLO 3
THEIS
JACOB – TIEMPO
JACOB – TIEMPO/DISTANCIA2
PERDIDAS DE CARGA
EJEMPLO 4
EJEMPLO 5
EJEMPLO 6
EJEMPLO 7
CI51J
PRUEBA DE BOMBEO 1
CI51J
PRUEBA DE BOMBEO 1
m2
T = 121
día
S = 2.48 ⋅10 −5
CI51J
METODO DE JACOB (TIEMPO)
∆s 2.3⋅ Q 2.3 ⋅ Q
m= = T=
∆Log (t ) 4 ⋅ π ⋅ T 4 ⋅π ⋅ m
2.25 ⋅ T ⋅ t 0
s (r , t ) = ⋅ Ln 2.25 ⋅ T ⋅ t 0
Q
=0 =1
4 ⋅ π ⋅T r ⋅S
2
r2 ⋅ S
2 .25 ⋅ T ⋅ t0
S=
r2
CI51J
PRUEBA DE BOMBEO 1
3.5
3.0
2.5
Descenso (m)
2.0
Datos Medidos
Jacob
1.5
m = 1.733
1.0
0.5
0.0
1 10 100 1000
CI51J
PRUEBA DE BOMBEO 1
∆s 2.3⋅ Q 2.3 ⋅ Q
m= = T=
∆Log (t ) 4 ⋅ π ⋅ T 4 ⋅π ⋅ m
2.3 ⋅ 0.96 m 2 m2 m2
T= = 0.101 = 146
4 ⋅π ⋅1.733 min min día
2.25 ⋅ T ⋅ t 0
s (r , t ) = ⋅ Ln 2.25 ⋅ T ⋅ t 0
Q
=0 =1
4 ⋅ π ⋅T r ⋅S
2
r2 ⋅ S
CI51J
EJEMPLO 1
EJEMPLO 2
EJEMPLO 3
THEIS
JACOB – TIEMPO
JACOB – TIEMPO/DISTANCIA2
PERDIDAS DE CARGA
EJEMPLO 4
EJEMPLO 5
EJEMPLO 6
EJEMPLO 7
CI51J
PRUEBA DE BOMBEO 2
Q = 5 m3/min
r=5m
CI51J
PRUEBA DE BOMBEO 2
100
10
Descenso (m)
0.1
0.01
1 10 100 1000 10000
CI51J
METODO DE JACOB (TIEMPO)
∆s 2.3⋅ Q 2.3 ⋅ Q
m= = T=
∆Log (t ) 4 ⋅ π ⋅ T 4 ⋅π ⋅ m
2.25 ⋅ T ⋅ t 0
s (r , t ) = ⋅ Ln 2.25 ⋅ T ⋅ t 0
Q
=0 =1
4 ⋅ π ⋅T r ⋅S
2
r2 ⋅ S
2 .25 ⋅ T ⋅ t0
S=
r2
CI51J
PRUEBA DE BOMBEO 2
1.0
0.9
0.8
0.7
0.6
Descenso (m)
Datos Medidos
0.5
Jacob
0.4 m = 0.253
0.3
0.2
0.1
0.0
0.1 1 10 100 1000 10000
CI51J
PRUEBA DE BOMBEO 2
∆s 2.3⋅ Q 2.3 ⋅ Q
m= = T=
∆Log (t ) 4 ⋅ π ⋅ T 4 ⋅π ⋅ m
2.3 ⋅ 5 m2 m2 m2
T= = 3.62 = 5,209
4 ⋅π ⋅ 0.253 min min día
2.25 ⋅ T ⋅ t 0
s (r , t ) = ⋅ Ln 2.25 ⋅ T ⋅ t 0
Q
=0 =1
4 ⋅ π ⋅T r ⋅S
2
r2 ⋅ S
CI51J
EJEMPLO 1
EJEMPLO 2
EJEMPLO 3
THEIS
JACOB – TIEMPO
JACOB – TIEMPO/DISTANCIA2
PERDIDAS DE CARGA
EJEMPLO 4
EJEMPLO 5
EJEMPLO 6
EJEMPLO 7
CI51J
PRUEBA DE BOMBEO 3
THEIS
CI51J
PRUEBA DE BOMBEO 3
CI51J
PRUEBA DE BOMBEO 3
THEIS
CI51J
W(u) = W* = 8.0
PRUEBA DE BOMBEO 3
1/u = 1/u * = 6000
P1 s = s* = 3.7 m
t = t* = 48 min
r = 5.5 m = 2880 seg
= 0.033 día
CI51J
PRUEBA DE BOMBEO 3
W(u) = W* = 8.0
P1
1/u = 1/u * = 6000
s = s* = 3.7 m
Q 691. 2 m2 m2
T= ⋅ W *
= ⋅ 8 . 0 = 118 . 9
4 ⋅ π ⋅ s* 4 ⋅ π ⋅ 3.7 día día
THEIS
CI51J
PRUEBA DE BOMBEO 3
P2
r = 40.5 m
W(u) = W* = 4.75
s = s* = 2.0 m
t = t* = 39 min
= 2440 seg
= 0.028 día
CI51J
PRUEBA DE BOMBEO 3
W(u) = W* = 4.75
P2
1/u = 1/u * = 180
s = s* = 2.0 m
Q 691.2 m2 m2
T= ⋅ W *
= ⋅ 4 . 75 = 130 . 6
4 ⋅π ⋅ s* 4 ⋅ π ⋅ 2.0 día día
THEIS
CI51J
W(u) = W* = 2.35
PRUEBA DE BOMBEO 3
1/u = 1/u * = 18.5
P3 s = s* = 1.0 m
t = t* = 37.5 min
r = 118.0 m = 2250 seg
= 0.026 día
CI51J
PRUEBA DE BOMBEO 3
W(u) = W* = 2.35
P3
1/u = 1/u * = 18.5
s = s* = 1.0 m
Q 691.2 m2 m2
T= ⋅ W *
= ⋅ 2 . 35 = 129 . 3
4 ⋅ π ⋅ s* 4 ⋅ π ⋅1.0 día día
THEIS
CI51J
PRUEBA DE BOMBEO 3
P1 P2 P3
2
T (m /día) 118.9 130.6 129.3
S 8.74E-05 4.79E-05 5.22E-05
CI51J
EJEMPLO 1
EJEMPLO 2
EJEMPLO 3
THEIS
JACOB – TIEMPO
JACOB – TIEMPO/DISTANCIA2
PERDIDAS DE CARGA
EJEMPLO 4
EJEMPLO 5
EJEMPLO 6
EJEMPLO 7
CI51J
PRUEBA DE BOMBEO 3
Transmisibilidad:
2.25 ⋅ T ⋅ t 2.3⋅ Q 2.25 ⋅ T ⋅ t
s (r , t ) = ⋅ Ln ⋅ Log
Q
=
4 ⋅ π ⋅T r 2
⋅ S 4 ⋅ π ⋅ T r ⋅S
2
2.3⋅ Q Q
s(r, t ) = a + b ⋅ Log (t ) b= T = 0.183 ⋅
4⋅π ⋅T ∆s
Coeficiente de Almacenamiento:
2.25 ⋅ T ⋅ t 0
s (r , t ) = ⋅ Ln 2.25 ⋅ T ⋅ t 0
Q
=0 =1
4 ⋅ π ⋅T r ⋅S
2
r2 ⋅ S
2 .25 ⋅ T ⋅ t0
S=
r2 JACOB
CI51J
PRUEBA DE BOMBEO 3
CI51J
PRUEBA DE BOMBEO 3
Q
Transmisibilidad: T = 0.183 ⋅
∆s
2.25 ⋅ T ⋅ t0
Coeficiente de Almacenamiento: S=
r2
P1 P2 P3
∆s (m) 0.92 - -
t0 (min) - 0.4 3.9
t0 (día) - 0.00027778 0.00270833
r (m) - 40.5 118
T (m2 /día) 137.5 - -
S - 5.24E-05 6.02E-05
JACOB
CI51J
EJEMPLO 1
EJEMPLO 2
EJEMPLO 3
THEIS
JACOB – TIEMPO
JACOB – TIEMPO/DISTANCIA2
PERDIDAS DE CARGA
EJEMPLO 4
EJEMPLO 5
EJEMPLO 6
EJEMPLO 7
CI51J
PRUEBA DE BOMBEO 3
JACOB 2
CI51J
PRUEBA DE BOMBEO 3
Transmisibilidad:
2.25 ⋅ T ⋅ t 2.3⋅ Q 2.25 ⋅ T ⋅ t
s (r , t ) = ⋅ Ln ⋅ Log
Q
=
4 ⋅ π ⋅T r 2
⋅ S 4 ⋅ π ⋅ T r ⋅S
2
2.3⋅ Q
s(r, t ) = a + b ⋅ Log 2
t Q
b= T = 0.183 ⋅
r 4⋅π ⋅T ∆s
Coeficiente de Almacenamiento:
2.25 ⋅ T ⋅ t 0
s (r , t ) = ⋅ Ln 2.25 ⋅ T ⋅ t 0
Q
=0 =1
4 ⋅ π ⋅T r ⋅S
2
r2 ⋅ S
2 .25 ⋅ T ⋅ t
S=
CI51J
PRUEBA DE BOMBEO 3
JACOB 2
CI51J
PRUEBA DE BOMBEO 3
m2
T = 129.1 S = 5.03 ⋅10−5
día
CI51J
EJEMPLO 1
EJEMPLO 2
EJEMPLO 3
THEIS
JACOB – TIEMPO
JACOB – TIEMPO/DISTANCIA2
PERDIDAS DE CARGA
EJEMPLO 4
EJEMPLO 5
EJEMPLO 6
EJEMPLO 7
CI51J
El descenso del nivel de agua en un pozo de bombeo incluye no sólo
el efecto del cono de depresión en el acuífero, sino que también las
pérdidas de carga causadas por el paso del agua a través de la rejilla
o criba del pozo hacia el interior del pozo.
CI51J Debido a que este último proceso es de tipo turbulento se ha
demostrado que su importancia es proporcional a la segunda potencia
del caudal, i.e., Q2.
sW = B ⋅ Q + C ⋅ Q2
C
sW CONDICION DEL POZO DE BOMBEO 2 5
(s /m )
Pozo bien diseñado y mantenido < 1,900
Pozo con deterioro menor 1,900 – 3,800
Pozo sin buen desarrollo > 3,800
Pozo con dificultades para su recuperación > 12,500
sW
= B + C ⋅Q
Q
CI51J
Descensos (m)
Caudal (l/s) Pozo de
Pozo MW1 Pozo MW2 Pozo MW3
Bombeo
10 1.10 0.54 0.32 0.17
15 1.84 0.80 0.48 0.24
CI51J
Descenso Teórico s − C ⋅Q 2
E= Eficiencia del Pozo = ⋅100 = W ⋅100
Descenso Medido sW
CI51J
EJEMPLO 1
EJEMPLO 2
EJEMPLO 3
THEIS
JACOB – TIEMPO
JACOB – TIEMPO/DISTANCIA2
PERDIDAS DE CARGA
EJEMPLO 4
EJEMPLO 5
EJEMPLO 6
EJEMPLO 7
CI51J
Si un pozo ha sido bombeado por un período de tiempo t y luego es
detenido bruscamente, el descenso residual puede ser calculado
fácilmente mediante superposición.
CI51J
CI51J
CI51J
CI51J
EJEMPLO 1
EJEMPLO 2
EJEMPLO 3
THEIS
JACOB – TIEMPO
JACOB – TIEMPO/DISTANCIA2
PERDIDAS DE CARGA
EJEMPLO 4
EJEMPLO 5
EJEMPLO 6
EJEMPLO 7
CI51J
PRUEBA DE BOMBEO 4
CI51J
PRUEBA DE BOMBEO 4
CI51J
PRUEBA DE BOMBEO 4
CI51J
EJEMPLO 1
EJEMPLO 2
EJEMPLO 3
THEIS
JACOB – TIEMPO
JACOB – TIEMPO/DISTANCIA2
PERDIDAS DE CARGA
EJEMPLO 4
EJEMPLO 5
EJEMPLO 6
EJEMPLO 7
CI51J
CI51J
IMAGINARIA
r1 P r2
Q Q
BARRERA
CI51J
Para el esquema anterior se tiene que en un punto cualquiera situado
en la zona izquierda de la barrera la depresión total queda dada por la
contribución de cada uno de los pozos:
r 2 ⋅S r 2 ⋅S
s P (r , t ) =
Q Q
⋅ W 1 + ⋅ W 2
4 ⋅π ⋅ T 4 ⋅T ⋅ t 4 ⋅π ⋅ T 4⋅T ⋅t
CI51J
Si utilizamos la aproximación de Jacob es necesario analizar el tiempo
en el cual el efecto del pozo real y del pozo imagen alcanza al punto
de interés:
r1 P r2
Q Q
r12 ⋅ S r22 ⋅ S
t1 = t2 =
2.25 ⋅ T 2.25 ⋅ T
BARRERA
Q 2.25 ⋅ T ⋅ t 2.25 ⋅ T ⋅ t
sP = ⋅ Ln 2 =0 =1
4 ⋅ π ⋅T r ⋅S r2 ⋅ S
CI51J
Si utilizamos la aproximación de Jacob es necesario analizar el tiempo
en el cual el efecto del pozo real y del pozo imagen alcanza al punto
de interés:
r12 ⋅ S
sP = 0 t<
2.25 ⋅T
Q 2.25 ⋅ T ⋅ t r12 ⋅ S r 2 ⋅S
sP = ⋅ Ln 2 ≤t < 2
4 ⋅ π ⋅T r1 ⋅ S 2.25 ⋅ T 2.25 ⋅ T
CI51J
El análisis de una prueba de bombeo realizada en una zona con
presencia de una barrera tendrá una forma como la indicada en la
figura siguiente.
r12 ⋅ S
t1 =
2.25 ⋅ T
r22 ⋅ S
t2 =
2.25 ⋅ T
CI51J
r1
d?
CI51J
Supongamos que se realiza una prueba de bombeo utilizando un pozo
de bombeo y un pozo de observación separados una distancia r1.
r2
Q
r1
2d
Q 2.25 ⋅ T ⋅ t
sP = ⋅ Ln 2
4 ⋅ π ⋅T r1 ⋅ S
CI51J
Desde la figura anterior es posible identificar los valores de depresión
s1 y s2, los que se producen luego de un tiempo t1 y t2 de iniciado el
bombeo.
Q 2.25 ⋅ T ⋅ t1
s1 = ⋅ Ln
4 ⋅π ⋅ T r1 ⋅ S
2
Q 2.25 ⋅T ⋅ t 2
s2 = ⋅ Ln
4 ⋅ π ⋅T r2 ⋅ S
2
CI51J
Los argumentos de los logaritmos deben ser iguales:
2.25 ⋅ T ⋅ t1 2.25 ⋅ T ⋅ t 2
=
r12 ⋅ S r22 ⋅ S
t2
r2 = r1 ⋅
t1
r1 + r2
d=
2
CI51J
2d
r2
Q r1
O1
r1
O2
r2
CI51J
CI51J
CI51J