SIGMACOVER 630

May 2012

CLEANING SOLVENT – Thinner 90-53

Film thickness and spreading rate

theoritical spreading rate m2/l 13.8 6.6 8.3 4.1


dft in μm 60 (for 125 (for 100 (for 200 (for
brush/ airless brush/ airless
roller) spray) roller) spray)

Maximum dft when brushing: 100 μm

Overcoating table for dft up to 150 μm

substrate temperature 10°C 20°C 30°C 40°C


with itself minimum interval 20 hours 9 hours 5 hours 3 hours
maximum interval 12 months 9 months 6 months 3 months

– surface should be dry and free from any contamination

Overcoating tabel for dft up to 150 μm

substrate temperature 10°C 20°C 30°C 40°C


with various alkyds minimum interval 24 hours 16 hours 8 hours 5 hours
maximum interval 21 days 10 days 7 days 3 days

– after exceeding of the maximum interval, glossy finishes require a


corresponding undercoat
– surface should be dry and free from any contamination
– best intercoat adhesion occurs when the subsequent coat is applied before
the preceding coat is fully cured
– if this time is exceeded it may be necessary to roughen the surface

Overcoating table for dft up to 150 μm

substrate temperature 10°C 20°C 30°C 40°C


with polyurethanes minimum interval 48 hours 24 hours 12 hours 6 hours
maximum interval 6 months 3 months 1 month 1 month

– surface should be dry and free from any contamination

page 3/6
SIGMACOVER 630

May 2012

Overcoating table for dft up to 150 μm

substrate temperature 10°C 20°C 30°C 40°C


with various two pack epoxy minimum interval 20 hours 9 hours 5 hours 3 hours
coatings
maximum interval 6 months 3 months 1 month 1 month

Curing Curing table for dft up to 150 μm


substrate touch dry full cure dry to handle
temperature
10°C 14 hours 15 days 20 hours
20°C 6 hours 7 days 9 hours
30°C 4 hours 4 days 5 hours
40°C 2 hours 2 days 3 hours

– adequate ventilation must be maintained during application and curing


(please refer to sheets 1433 and 1434)

Pot life (at application viscosity)

15 °C 3 hours
20 °C 2 hours
30 °C 1 hour
40 °C 0.5 hour

Worldwide availability Whilst it is always the aim of Sigma Coatings to supply the same product on a
worldwide basis, slight modification of the product is sometimes necessary to
comply with local or national rules/circumstances.
Under these circumstances an alternative product data sheet is used.

REFERENCES Conversion tabels see information sheet 1410


Explanation to product data sheets see information sheet 1411
Safety indications see information sheet 1430
Safety in confined spaces and health safety
Explosion hazard - toxic hazard see information sheet 1431
Safe working in confined spaces see information sheet 1433
Directives for ventilation practice see information sheet 1434
Cleaning of steel and removal of rust see information sheet 1490
Specification for mineral abrasives see information sheet 1491
Relative humidity - substrate temperature -
air temperature see information sheet 1650

page 4/6