Q2. Considering the free vibration data for a three storied building as given below, calculate the design
seismic forces and lateral force distribution using SRSS. The building is a SMRF structure situated in
Patiala. The soil beneath the structure is a hard rock and the height of each storey is 3 m. The seismic
weights of the top, middle and bottom stories are 640 kN, 690 kN and 690 kN respectively. Mode
shapes and natural periods of vibration for the three modes of vibration are given as:
1 1 1
1 0.802 , 2 0.555 and 3 2.247 and T1 = 0.0647, T2 = 0.023 and T3 = 0.016, respectively.
0.445 1.246 1.802
Q3. For Q2 above, compare the computed design base shear with the base shear calculated using the
fundamental period. Apply base shear correction. The dimensions of the building are 27 m × 11 m.
Assume infill walls on all the beams. Show the distribution of lateral force at each storey in the larger
and shorter directions considering all the modes.