Professional Documents
Culture Documents
INTRODUCTION
The model HW/TW/AW program version 02001010 can be divided into 2 types :
The standard division scale ( 1 / 3000 ~ 1/ 10000 )
The high precision division scale ( over 1 / 10000 ~ 1 / 15000 )
FEATURES
1. High performance in A/D converter
w 0.3uv/D sensitivity
w Sample speed 16 times / second
w Maximum resolution : 15000
w Non-linearity 0.01 % FS
w -1 mv ~ +5 mv
w Used range –1 mv ~ +14 mv
w Load cell excitation power 5VDC ±5% 100mA ( can be connected with 4 sets of 350Ω load
cells )
6. AC / DC power supply
7. LCD display
9. With built-in-backlight
ERROR MESSAGE
-1- SM2020010106
05/07/19
E8 ⇒ Internal resolution is too high out of its range.
-2- SM2020010106
05/07/19
UNITS
. .
. . . Pcs
. . . .
PT M+ PST PT M+
⇒
RE- ∧ ∧
ZERO → 0←
CALL BL
R
PRINT
TARE CE T CE
↵ ↵
M+ +
⇒
RE- ∧
ZERO
CALL BL
→ 0← R ∧
PRINT
TARE CE
↵
T CE ↵
-3- SM2020010106
05/07/19
-4- SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
FUNCTION SETTING
♦ Turn on the machine, while the scale is counting backward to zero, press and hold ZERO key
until the display appears the program version no. “ ”.
Then, release your finger from ZERO key, the display will appear “ ” in the calibration mode.
Press TARE
Press ∧
Press TARE
Press ∧
Press TARE
Press ∧
Press TARE ⇒ WEIGHT CALIBRATION
⇒ SPECIFICATION SETTING
Press ∧
Press TARE
⇒ NOISE FILTER SETTING
Press ∧
Press TARE ⇒ SHOWING THE INTERNAL VALUES
Press ∧
Press TARE
Press ∧
-5- SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
F0 ⇒ WEIGHT CALIBRATION
♦ Before calibrating, please adjust the mini jumper SWA1 to “ADJ” position.
♦ After finishing the calibration, please re-adjust the mini jumper SWA1 to “LOCK” position.
Press ↵
ï ð .
kg
Press ∧ and ↵
to input the “calibrated weight* value”
. kg
“calibrated weight”*
should be over 0 weight or any weight
Put 3kg weight on the scale, less than the full capacity of scale.
Press ↵
While stable
Buzzer “beep”
. kg
F0 calibration is finished
return to weighing mode
-6- SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
F1 ⇒ SPECIFICATION SETTING
♦ Before calibrating, please adjust the mini jumper SWA1 to “ADJ” position.
♦ After finishing the calibration, please re-adjust the mini jumper SWA1 to “LOCK” position.
Press ↵
⇒
Showing the internal resolution
E6 ⇒ over 360000
E7 ⇒ less than 240000
Press ↵
∧ = key for moving up (0,1,2,3,4,5,6,7,8,9)
ï ð ↵ = key for moving right
Press ∧ and ↵ ZERO = confirm key CE = cancel key
to key in the setting number
ï ð
⇒ To select unit mode
1 = kg 2 = lb
Press ZERO EX :
“kg” only, you keyin 100xx0
“lb” only, you keyin 200xx0
kg “kg”, “lb” units, keyin 120xx0
ï ð
th
4 digit ⇒ 0 = kg display、1 = g display
Press ∧ and ↵
th
to key in the setting number 5 digit ⇒ 0 = lb display、1 = lb, oz display
kg
ï ð ⇒ Full capacity + 9d ( Max. “lb” weight = Max. “kg” x 2 times )
EX :
“3kg×1g”&“30kg×10g”&“300kg×100g” keyin 003009
Press ZERO “6kg×2g”&“60kg×20g”&“600kg×200g” keyin 006018
“15kg×5g”&“150kg×50g” keyin 015045
kg
ï ð ⇒ Weight specification setting
st
1 digit =division (1,2,5)
Press ∧ and ↵ nd
2 digit = decimal
to key in the setting number rd th th th
3 , 4 , 5 , and 6 digits are” 0 ”
kg
ï ð
Press ZERO
-7- SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
♦ Before calibrating, please adjust the mini jumper SWA1 to “ADJ” position.
♦ After finished the calibration, please re-adjust the mini jumper SWA1 to “LOCK” position.
Press ↵
The display shows
the factory setting
Press ∧
to input the setting number
∧ = key for moving up (01~15)
Press ↵
-8- SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
♦ Before calibrating, please adjust the mini jumper SWA 1 to “ADJ” position.
♦ After finished the calibration, please re-adjust the mini jumper SWA1 to “LOCK” position.
Press ↵
Press ∧
⇒ Normal mode
Press ∧
Press ∧
Press ↵
F4 ⇒ CHECK-WEIGHING FUNCTION
Press ↵
CANCEL “H” , “L” & “B” VALUE
ï ð . . ï ð
kg Press ↵ 5 times kg
Press ↵
“ LOW LIMITS ”
( Low Limit > 10d, d = division )
Press ∧ and ↵
to set “ Low Limit ” EX: low limit =2kg
kg
. ï ð
∧ = for moving up (0,1,2,3,4,5,6,7,8,9)
↵ = confirm key
Press ↵
ï ð .
kg
“ HIGH LIMITS ”
( High Limit ≥ Low Limit )
Press ∧ and ↵
to set “ High Limit ” EX: High Limit =2.5 kg
. ï ð
kg
- 10 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
Press ↵
Χ Χ
kg A B
ï ð A ⇒ 0 = Stable, beeps & LCD on.
“ ALARM ” 1 = Stable, beeps, whether stable or not, LCD on.
Press ∧ and ↵ 2 = Whether stable or not, beeps & LCD on.
to set “ alarm limit ” EX: alarm value=22 B ⇒ 0 = No beeps
1 = OK (over low limits and under high limit), beeps
kg 2 = Under or equal to low limit ( must be over 10d )
ï ð and over or equal to high limit, beeps
♦ LCD INDICATION:
Press ↵
ïLOWð ïOKð ïHIGHð
ïïïïïïðððððð
10d LOW LIMIT HIGH LIMIT
- 11 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
Press ↵
The screen displays transmitting mode
(factory setting)
∧ key = 0 ~ 4 number
Press ∧ ↵ key = confirm key
to select transmitting mode
Press ↵
The screen displays baud rate values
(factory setting)
∧ key = 1200、2400、4800、9600
Press ∧
↵ key = confirm key
To select baud values
(1200、2400、4800、9600)
⇒ No transmit
⇒ Press ↵ to transmit
(complete mode, for serial printer)
⇒ Stable transmit (accumulation)
- 12 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
4 To select transmitting mode for EZ-2 printer , the baud values must be select 9600bps
- 13 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
DATA ( 8 BYTES )
2D ( HEX ) = “ – ” ( MINUS )
2E ( HEX ) = “ . ” ( DECIMAL POINT )
UNIT ( 2 BYTES )
kg = 6B ( HEX ) ; 67 ( HEX )
lb = 6C ( HEX ) ; 62 ( HEX )
Transmit example:
1. Example +0.876kg when it is stable and net value :
S T , N T , + 0 . 8 7 6 k g 0D 0A
- 14 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
HEAD , HEAD , DATA UNIT C LF
- 15 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
- 16 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
+100.0 kg
- 17 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
Press ↵
Scale revert to 0
Press ↵
Internal value
- 18 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
Press ↵
- 19 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
Press ↵
Press ∧
Press ∧
Press ∧
Press ∧
Press ↵
= No hold function.
= In the continuos changing weight value, the scale will automatically hold
the maximum value displaying on the screen.
Press any key except PRINT key to cancel the hold function.
= When it is stable, the scale will hold the value which is displaying on the screen.
Press any key except PRINT key to cancel the hold function.
= When it is stable, the scale will hold the value which is displaying on the
screen. When the scale returns to 0 (the weight is less than 10 division),
the hold function mode will be released.
- 20 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
- 21 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
Press ↵
= UNLOCK
Press ∧
Press ∧ = LOCK
Press ↵
- 22 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
LINEARITY CALIBRATION INSTRUCTION
♦ While turning on the machine, press and hold TARE key, the display will appears
Then, release your finger from TARE key, the display is in the calibration mode .
Press TARE
Press ∧
Press TARE
Press ∧
Press TARE
Press ∧
⇒ Linearity modification
⇒ No use
Press ↵
Scale reverts to 0
- 23 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
- 24 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
C0 ⇒ Linearity procedures
♦ Maximum linearity calibration is up to 10 steps. The more linearity calibration is done, better
stability of linearity performance is.
♦ Before calibration, please adjust the mini jumper SWA1 to “ADJ” position.
♦ After finished the calibration, please re-adjust the mini jumper SWA1 to “LOCK” position.
♦ Please refer to the appendix 2 for the linearity table list.
Press ↵
*Internal value
Press ↵
1 calibration step
st
Press ↵
*Internal value
Put 5kg
Press ↵
3 calibration step
rd
Press ↵
*Internal value
Put 5kg
Press ↵
linearity calibration is finished,
scale reverts 0
Press CE
- 25 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
APPENDIX 1 :
TABLE LIST FOR THE DIFFERENT SPECIFICATION SETTING
1. Capacity specs.
2. Reference number for the unit of calibrated weight.
3. Full capacity + 9 division.
4. Reference number for division and decimal.
- 26 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
030018 015009
6 6
240000 (3 kg) 130000 (15 kg)
230000 (30 kg) 120000 (150 kg)
220000 (300 kg) 110000 (1500 kg)
210000 (3000 kg) 66
66
- 27 - SM2020010106
PDF created with pdfFactory Pro trial version www.pdffactory.com
05/07/19
3 kg 6 kg 12、15 kg
01 1 1 kg 01 1 2 kg 01 1 5 kg
02 1 1 kg 02 1 2 kg 02 1 5 kg
03 1 1 kg 03 1 2 kg 03 1 5 kg
24、30 kg 60 kg 120、150 kg
01 1 10 kg 01 1 20 kg 01 1 50 kg
02 1 10 kg 02 1 20 kg 02 1 50 kg
03 1 10 kg 03 1 20 kg 03 1 50 kg
240、300 kg 600 kg
01 1 100 kg 01 1 200 kg
02 1 100 kg 02 1 200 kg
03 1 100 kg 03 1 200 kg
- 28 - SM2020010106