The 88-story mixed-use tower has 50 stories of office space and 38 stories of hotel space. It uses a composite structural system of reinforced concrete and structural steel. Mega composite columns and a core wall are connected by outrigger trusses and horizontal slabs to maximize the structure's effective depth and resist extreme lateral loads. The system achieves 70% structural efficiency through slight inefficiencies. Piles 65.7 meters long support the foundation.
Original Description:
Poster describing the structural system of the famous Jin Mao Tower
The 88-story mixed-use tower has 50 stories of office space and 38 stories of hotel space. It uses a composite structural system of reinforced concrete and structural steel. Mega composite columns and a core wall are connected by outrigger trusses and horizontal slabs to maximize the structure's effective depth and resist extreme lateral loads. The system achieves 70% structural efficiency through slight inefficiencies. Piles 65.7 meters long support the foundation.
The 88-story mixed-use tower has 50 stories of office space and 38 stories of hotel space. It uses a composite structural system of reinforced concrete and structural steel. Mega composite columns and a core wall are connected by outrigger trusses and horizontal slabs to maximize the structure's effective depth and resist extreme lateral loads. The system achieves 70% structural efficiency through slight inefficiencies. Piles 65.7 meters long support the foundation.
General System Description Mixed Structural System and Influence on
Plan area of 280,000 m2 Jin
Behaviour An 88 story (421 m) tall tower. With 50 stories of office space and 38 stories of hotel space, and 3 levels of basement Mao Reinforced concreted combined with structural steel was Aspect ratio 8:1 The vertical elements of the mega Tower, strategically placed to resist extreme lateral loads. Reducing the redundancy of structural elements, forcing the structure are: Shanghai system to approach global static determinacy, significantly increasing economy. Mega composite column Due to slight inefficiencies the system was 70% efficient.
Wind Engineering and Seismic Design
Strength design of the structure is based on a code specified 100 year return wind with basic wind speed of 32.5 m/sec for a 10 Core minute average time for the towers. wall Response spectrum and Time history analysis were considered and used for final analysis and design. Mega steel column Pin concept
How does the structural system work?
Core and mega columns are linked by structural steel outrigger trusses acting compositely with horizontal diaphragm slabs. These are maximizing the effective depth of the structure .
Fire Egress Features
Resistance to gravity loads: This includes 8 structural steel built-up mega-columns and composite wide Stairs interrupt at refuge floors, which Located at levels 24 and 26, levels 51 and 53 (left), and between levels 85 and the roof (right) flanged beams and built-up trusses used to frame allows transfer to other stairs. The roof reflects the pagoda form of the truss system - an the floors. The framing trusses are of 4.5 m c/c with a The refuge floors have 2 hour efficient form of transfer of lateral loads between core and the composite metal deck slab with 75 mm and deep enclosure and mechanical exterior composite columns by providing continuum over the metal deck slab with 80 mm normal weight topping pressurization. open core. the slab. Foundation System: Deep piles of length 65.7 m, 4 m Resistance to lateral loads: 4 composite deep reinforced concrete mat and a continuous mega columns activated in each primary reinforced concrete slurry wall along the perimeter direction, 8 composite mega column in the have been installed. Based on the tower load, the pile diagonal direction. These columns are length and the soil conditions, the expected subjected to axial forces induced from the Ankita Roy Chowdhury (PT400116) settlement for the tower was upto 50 mm. overall bending moments. Soumyakanti Dhavala (PT402016)