NORTH AMERICA Pressurised p 50016 -2 Protection by gas exclusion - analysers *Located in non-hazardous area and may be connected to hazardous area
** Hazardous-area apparatus
Powder filled q 50017 -5 Protection by gas exclusion - weighing machines
NEC 505 Gas Zone 0 Zone 1 Zone 2 Listed in NEC® Article 505-5
NEC 500 Gas & Dust Division 1 Division 2 Listed in NEC® Article 500-3(c) Flameproof d 50018 -1 Prevention of propagation of internal explosion - dc motors
CENELEC IEC
Increased safety e 50019 -7 Prevention by design - induction motors MARKING MARKING SUB DIVISIONS OF TYPE n
Intrinsic safety ia 50020 -11 Low energy. Safe with two faults - Level measurement R R Restricted breathing
enclosures
Intrinsic safety ib 50020 -11 Low energy. Safe with one fault - displays
GAS GROUPING INGRESS PROTECTION Intrinsically safe systems 50039 -25 Considers combinations of intrinsically safe apparatus
L L Energy limited apparatus
NO PROTECTION 0 0 NO PROTECTION
ACETYLENE IIC A 20
OBJECTS GREATER THAN 5Omm 1 1 VERTICALLY DRIPPING WATER Codes of Practice Explosion Protection - Europe
- Selection, installation, inspection, maintenance
OBJECTS GREATER THAN 12mm 2 2 ANGLED DRIPPING WATER -75O TO 90O for gas atmospheres
HYDROGEN IIC B 20 REMARKS
OBJECTS GREATER THAN 2.5mm 3 3 SPRAYED WATER CEN
CENELEC IEC
ETHYLENE IIB C 60
OBJECTS GREATER THAN 1.0mm 4 4 SPLASHED WATER EN 60079 60079 REMARKS Explosion prevention EN 1127-1 Part 1 -
Basic concepts &
methodology
DUST PROTECTED 5 5 WATER JETS & protection for all industries
Classification of hazardous areas -10 -10 New IEC version published 2002
DUST TIGHT 6 6 HEAVY SEAS except mining
PROPANE IIA D 180 Electrical Installations -14 -14 New IEC version published 2002
7 EFFECTS OF IMMERSION
EXAMPLE IP65 Inspection and maintenance -17 -17 New IEC version published 2002 Basic concepts
Explosion prevention EN 1127-2 Part 2 -
Equipment is dust-tight and 8 INDEFINITE IMMERSION Repair and overhaul -19 -19 & methodology
*North America hazard categories: Class I (Gasses & Vapours); Class II (Dusts); Class III (Fibres) & protection
protected against water jets. for mining
Data for flammable gases -20
Simple Apparatus
IGNITION TEMPERATURE/ Mechanical Impacts (IK) Code EN50102 Group II Electrical Apparatus Permitted Zone
for combustible dusts D ATEX category
TEMPERATE CLASS (T CLASS) IK code IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 REMARKS
Passive components JB
C
O Degrees of protection provided by enclosures for electrical equipment against mechanical impacts Code EN 61241 1 2 3 Well defined sources of stored
700
O
energy considered in safety analysis
Note: IEC are currently working on a programme to introduce a parallel series of standards for combustible dusts reflecting the IEC 60079 - gas atmosphere standards.
300
O
T2 300O
IIA T3 CYCLOHEXANE 259 O
1 IP20 Indoor, from contact with contents They have agreed to re-number the parts as shown below. It is anticipated that a number of these will be published by the end of 2003 *Note: North America still uses 1.2V and 20 microjoules
200
O
T3 200O 2 IP22 Indoor, limited, falling dirt &water
Fieldbus in hazardous areas
EW
IEC
N
100
O
T5 100O dust & ice damage IEC PROPOSED
STANDARD
TITLE
CODE
STATUS STANDARD TITLE
T6 85O
NUMBER
NUMBER
3R IP24 Outdoor, from rain, sleet & ice damage The Fieldbus Intrinsically safe Concept
4 IP66 Indoor & outdoor, from windblown General requirements for electrical apparatus (FISCO) IEC60079-27 Technical
}
61241-0 -
dust, rain, splashing & hose directed for use in presence of combustible dusts Enclosure protected, temperature limitation - construction
water & ice damage 61241-1-1
and testing Specification will move to Standard
WORK IN PROGRESS
61241-1 Protection by enclosure tD
SMALL COMPONENT RELAXATION 4X IP66 Indoor & outdoor, from corrosion, status in the near future. The benefits
windblown dust, rain, splashing & 61241-2 Type of protection pD - pressuriastion pD 61241-4 Type of protection pD
}
>20mm2<10mm2 Surface temperature <200OC & ice damage Selection and installation for electrical
61241-14 apparatus for dusts
- Selection, installation and maintenance of apparatus meeting Division 2. Further details are contained
>20mm2 Power dissipation <1.3 W* 61241-1-2
12 IP54 Indoor, from dust, falling dirt & IEC61241-1-1 above
at 40OC ambient dripping non-corrosive liquids 61241-17 Inspection and maintenance requirements - in MTL Application Notes AN9026 FISCO
61241-18 Apparatus protected by encapsulation mD - -
13 IP54 Indoor, from dust, spraying water, oil and AN9027 FNICO (Fieldbus Non-
O
*Reduced to 1.2 W with 60 C ambient or 1.0 W with 80 C ambient
O
& non-corrosive liquids Test methods for dust other parts will also Methods for determining minimum ignition temperatures
61241-20-1 be generated
- 61241-2-1 Incendive Concept)
of dust
enquiry@mtl-inst.com
www.mtl-inst.com