You are on page 1of 7

PROJECT : BELLEMARE STAIR

ADRESS : 29 ISLA BAHIA DRIVE FT. LAUDERDALE FL, 33316

Steel Stair Design Based on AISC Manual 9th

INPUT DATA & DESIGN SUMMARY HSS4X4X1/2

STRINGER - 1 (Channel or Tube) => HSS8X2X3/8


HSS8X2X3/8
Tube A d Ix Sx
6,18 8,00 38,20 C1
9,56
2X20.7

LANDING BEAM - 1 (Channel or Tube) => HSS10X2X3/8


HSS10X2X3/8
Tube A d Ix Sx
7,58 10,00 71,70 14,30
C6X13

DIMENSIONS H = 14 ft, story Ht


L1 = 8,167 ft
L2 = 4,333 ft
L3 = 12,167 ft

NUMBER OF STORIES n = 1

GRAVITY LOAD DL = 63 psf


LL = 40 psf

THE STAIR DESIGN IS ADEQUATE.

ANALYSIS

STRINGER - 1

q = 40,60 deg, from horizontal


w = 0.5 (DL / Cos q + LL) L3 = 748 plf , projected
R = 0.5 w (L1 + 0.5 L2) = 3,87 kips
M = w (0.5 L2 + L1 ) 2 / 8 = 9,99 ft-kips
fb = M / Sx = 12,53 ksi
Fb = 0.6 Fy = 27,60 ksi > fb [Satisfactory]
E = 29000 ksi
DLL = 5 (wLL Cos q) ((L2 + L1 )/ Cos q)4 / (384 E I) = 0,27 in
< (L2 + (L1 / Cos q)) / 240 = 0,65 in [Satisfactory]

LANDING BEAM - 1

w = (DL + LL) L2 = 446 plf


P = 3,87 kips, from 2-STRINGERS
R = 0.5 w L3 + P = 6,58 kips
M = w L32 / 8 + P L3 / 2 = 31,77 ft-kips
fb = M / Sx = 26,66 ksi
Fb = 0.6 Fy = 27,60 ksi > fb [Satisfactory]
DLL = 5 wLL L34 / (384 E I) + PLL L33 / (24 E I) = 0,13 in
< L3 / 240 = 0,61 in [Satisfactory]
PROJECT : BELLEMARE STAIR
ADRESS : 29 ISLA BAHIA DRIVE FT. LAUDERDALE FL, 33316

Weld Capacity of Eccentric Connection Based on AISC 360-10/16

INPUT DATA & DESIGN SUMMARY


THICKER PART JOINTED t = 0,375 in
WELD SIZE w = 0,25 in
ECCENTRICITY TO EDGE x = 0 in
WELD LENGTH D= 10 in
GRAVITY LOAD, ASD P = 13,16 kips
LATERAL LOAD, ASD F= 5 kips

THE CONNECTION DESIGN IS ADEQUATE.


ANALYSIS
MIN WELD SIZE (AISC 360 Tab. J2.4) w min = 0,19 in
MAX WELD SIZE (AISC 360 J2.2b) w max = 0,31 in
EFFECTIVE THROAT THICKNESS t e= 0.707 w = 0,18 in
CENTRODIAL MOMENT OF INERTIA Ix = 2 (t e D3 / 12 ) = 29,5 in4
DIRECT SHEAR STRESS fx= F/2Dte = 1,4 ksi
fy= P/2Dte = 3,7 ksi
BENDING STRESS fx= D P x/2 Ix = 0,0 ksi
RESULTANT STRESS fv= [( Sf x)2 + f y2 ) 0.5 = 5,1 ksi

ALLOWABLE STRESS (AISC 360 J2.4 ) Fv = 0.6 FEXX / W = 21,0 ksi


> fv = 5,1 ksi [Satisfactory]
PROJECT : BELLEMARE STAIR
ADRESS : 29 ISLA BAHIA DRIVE FT. LAUDERDALE FL, 33316

Stringer to Wall Anchorage Design Based on TMS 402-16/13

INPUT DATA & DESIGN SUMMARY


MASONRY STRENGTH
f m' = 1,5 ksi
FASTENER YIELD STRESS
fy = 60 ksi
SERVICE VERTICAL LOAD
P = 6,58 kips
VERTICAL LOAD TO FACE DIMENSION
e = 0 in
SERVICE HORIZONTAL TENSION LOAD
T = 5 kips
WALL THICKNESS
b = 8 in
FASTENER DIAMETER f = 3/4 in
EFFECTIVE EMBEDMENT Lb = 6 in [THE BEAM ANCHORAGE DESIGN IS ADEQUATE]
DISTANCE TO WALL TOP Lbe = 48 in
NO. ANCHORS (4,6,or 8) n = 6 MIN. FACE PLATE SIZE - 7 in x 27 in
SPACING Sh = 4 in, o.c. 7
VERTICAL SPACING Sv = 12 in, o.c. 27

ALLOWABLE INCREASING ? (IBC/CBC 1605.3.2) Yes

ANALYSIS
ANCHOR LOCATION & FORCE
MAX TENSION STRESS, ASD Anchor X (in) Y (in) XCG2 YCG2 Na Va
ba = 1,2 kips / fastener 1 -10,00 -5,50 100,00 30,25 1,2 1,1
MAX SHEAR STRESS, VERTICAL 2 10,00 -5,50 100,00 30,25 1,2 1,1
bv = 1,1 kips / fastener 3 -10,00 5,50 100,00 30,25 -0,6 1,1
GOVERNING SPACING 4 10,00 5,50 100,00 30,25 -0,6 1,1
S = 4 in, o.c. 5 #¡VALOR! #¡VALOR! 1,1
6 #¡VALOR! #¡VALOR! 1,1
7 #¡VALOR! #¡VALOR! 1,1
8 #¡VALOR! #¡VALOR! 1,1
CHECK MIN. EMBEDMENT (TMS 402-16/13 6.3.6/6.2.6) 1,12 4,4
Lb,min = MIN[ 4f , 2] = 2,00 in < Lb TRUE

CHECK TENSION CAPACITY FOR A FASTENER (TMS 402 8.1.3.3.1)


Ba = MIN[ 1.25A pt (f m ') 0.5 , 0.6A bf y ] = 2,28 kips / fastener

> k ba = 0,86 kips / fastener TRUE

Where L = MIN[ Lb , Lbe] = 6,00 in, conservative value


q = COS-1(0.5Sh / L) = 1,23 rad
A seg = L2 [ q - 0.5 SIN(2q)] = 33,00 in2

A pt = p L2 - 2A seg = 47,10 in2 (TMS 402-16/13 6.3.2/6.2.2)

A b = p f2 / 4 = 0,44 in2

k= 3/4

CHECK SHEAR CAPACITY (TMS 402 8.1.3.3.2)


Bv = MIN[1.25A pv (f m ') 0.5 , 350(A bf m ') 1/4 , 2.5A pt (f m ') 0.5 , 0.36A bf y ] = 1,78 kips / fastener 9,29247 1,7758 5,58486 9,542588
> bv = 1,10 kips / fastener , Gravity only TRUE

Where q = COS-1(0.5S / Lbe) = 1,53 rad


2
A seg = Lbe2 [ q - 0.5 SIN(2q)] = 3427,17 in
A pv = 0.5(p Lbe2 - 2A seg) = 191,94 in2 (TMS 402-16/13 6.3.3/6.2.3)

CHECK COMBINED SHEAR AND TENSION CAPACITY (TMS 402 8.1.3.3.3)


(ba / Ba) (5/3) + (bv / Bv ) (5/3) = 0,77 < 1,00 TRUE
PROJECT : BELLEMARE STAIR
ADRESS : 29 ISLA BAHIA DRIVE FT. LAUDERDALE FL, 33316

Wind Analysis for Freestanding Wall & Sign Based on ASCE 7-10

INPUT DATA 24
Exposure category (B, C or D) = C
Importance factor, 1.0 only, (Table 1.5-2) Iw = 1,00
Basic wind speed (ASCE 7-10 26.5.1) V = 170 mph
Topographic factor (26.8 & Table 26.8-1) Kzt = 1 Flat
Height of top h = 18,17 ft
Vertical dimension (for wall, s = h) s = 4,17 ft
Horizontal dimension B = 5 ft
Dimension of return corner Lr = 0,06562 ft

DESIGN SUMMARY
Max horizontal wind pressure p = 85 psf
Max total horizontal force at centroid of base F = 1,77 kips
Max bending moment at centroid of base M = 28,42 ft-kips
Max torsion at centroid of base T = 1,77 ft-kips

ANALYSIS
Velocity pressure
qh = 0.00256 Kh Kzt Kd V2 = 55,44 psf
where: qh = velocity pressure at mean roof height, h. (Eq. 29.3-1 page 307 & Eq. 30.3-1 page 316)
Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 29.3-1, pg 310) = 0,88
Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250) = 0,85
h = height of top = 18,17 ft

Wind Force Case A: resultant force though the geometric center (Sec. 29.4.1 & Fig. 29.1-1)
p = qh G Cf = = 85 psf
F = p As = 1,77 kips
M = F (h - 0.5s) for sign, F (0.55h) for wall = 28,42 ft-kips
T= = 0,00 ft-kips
where: G = gust effect factor. (Sec. 26.9) = 0,85
Cf = net force coefficient. (Fig. 29.4-1, page 311) 1,80
As = B s = 20,8 ft2

Wind Force Case B: resultant force at 0.2 B offset of the geometric center (Sec. 29.4.1 & Fig. 29.1-1)
p = Case A = 85 psf
F = Case A = 1,77 kips
M = Case A = 28,42 ft-kips
T = 0.2 F B = 1,77 ft-kips

Wind Force Case C: resultant force different at each region (Sec. 29.4.1 & Fig. 29.4-1)
p = qh G Cf
F = S p As
M = S [ F (h - 0.5s) for sign, F (0.55h) for wall ]
T = S Ts

s Distance Cf Pi Asi Fi Mi Ti
0 (ft) (Fig. 29.4-1) (psf) (ft2) (kips) (ft-kips) (ft-kips)
2,25 1 4,2 2,250 106 17,3611 1,84 29,61 0,77
1,50 2
1,50 3
1,50 4
1,50 5
1,50 10
1,50 B 5,0 1,500 71 3,47222 0,25 3,95 -0,51
S 2,09 33,56 0,26 <== Case C may not be considered, footnote 3 of Fig. 6-20
PROJECT : BELLEMARE STAIR
CLIENT : 29 ISLA BAHIA DRIVE FT. LAUDERDALE FL, 33316

Structural Glass Design, Based on ASTM E1300 & CAN/CGSB-12.20, using Finite Element Method

INPUT DATA & DESIGN SUMMARY


GLASS PANEL SIZE W= 4,17 ft
L= 5 ft

GLASS PANEL THICKNESS t = 0,7874 in, (20 mm)


Weight = 214 lbs
0,09051
CONNECTION TYPE ( 0 or 1) 0 , only corner pinned.

s allow =
2
ALLOWABLE GLASS STRENGTH 14,5 ksi, (24 N / mm )
(Annealed: 3.5 ksi, Heat-strengthened: 6.5 ksi, Tempered: 14.5 ksi - verify reqd.)

ALLOWABLE DEFLECTION L / 240


( The max value suggested: L / 60 for window or curtain wall, L / 180 for stair.)

UNIFORM AREA LOAD (Perpendicular to Plane) D= 85 psf, ASD level


POINT LOAD (Including Impact Factor) P= 1,77 kips, ASD level

THE DESIGN IS ADEQUATE.

ANALYSIS
GLASS PROPERTIES
g = 156 lbs / ft 3 (2500 kg / m 3 )
2
E= 10150 ksi (70 kN / mm )
u = 0,22 , Poisson's ratio

JOINT DEFLECTIONS, REACTIONS, & PLATE SECTION FORCES


P= 1,77 kips,( Point load at Joint 9.)

Joint D R Bending M
Number in kips Section ft-k/ft
1 0 -0,09 7-8 0,03
2 0,14 8-9 0,04
3 0,21 3-6 0,42
4 0,00 6-9 0,42
5 0,14
6 0,21
7 0,00
8 0,14
9 0,21

CHECK BENDING CAPACITY


Mn / Wb = s allow d t 2 / 6 = 17,98 ft-k/ft > M = 0,42 ft-k/ft
[Satisfactory]
Where d= 12 in, (1 ft)
2 2 0.5
M = (M 6-9 + M 8-9 ) = 0,42 ft-k/ft

CHECK DEFLECTION
D max = 0,21 in < L / 240 = 3,00 in
[Satisfactory]
Where L = Max (L , W) = 60,0 in
PROJECT : BELLEMARE STAIR
ADRESS : 29 ISLA BAHIA DRIVE FT. LAUDERDALE FL, 33316

Group of Tension and Shear Fasteners Near Two Edges Based on ACI 318-14

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH f c' = 3 ksi
SPECIFIED STRENGTH OF FASTENER f uta = 58 ksi
(T he strength of most fastenings is likely to be controlled by the embedment strength rather
than the steel strength, so it is usually economical to use AST M A307 Grade A fastener.)
FACTORED DESIGN TENSION LOAD Nua, 1 = 1,77 k
FACTORED DESIGN SHEAR LOAD V ua, 1 = 0,214 k
EFFECTIVE EMBEDMENT DEPTH hef = 3,5 in
FASTENER DIAMETER d = 0,5 in
FASTENER HEAD TYPE 4 Heavy Hex
( 1=Square, 2=Heavy Square, 3=Hex, 4=Heavy Hex, 5=Hardened Washers )
FASTENER CENTER-TO-CENTER SPACING s = 3 in
DIST. BETWEEN THE FASTENER AND EDGE c1 = c 1a = 6 in
DIST. BETWEEN THE FASTENER AND EDGE c2 = c 2a = 3,5 in
SEISMIC LOAD ? (ACI 318 17.2.3) Yes
[THE FASTENER DESIGN IS ADEQUATE.]
ANALYSIS
NUMBER OF FASTENERS n = 2
EFFECTIVE AREA OF FASTENER A se,N = 0,142 in2

BEARING AREA OF HEAD Ab = 0,467 in2, ( or determined from manufacture's catalogs.)


CHECK THE FASTENERS TENSILE STRENGTH : (ACI 318 17.4.1.2)

f N sa  f n Ase, N  f uta  = 12,354 k > Nua = 4,425 k [Satisfactory]

w here : f = 0,75 x 1 = 0,75 , (ACI 318-14 17.2.3.4.4)


W0 = 2,50 , ASCE 7-10 Tab. 12.2-1 or 15.4-1

CHECK CONCRETE BREAKOUT STRENGTH : (ACI 318 17.4.2.1)


 0.3 

f N cbg  f A N y ec , Ny ed , Ny c , N N b  f A N2 y ec , N  0.7  c min y c , N 24 f 'c h1.5
A No 9hef   1.5hef  ef 
= 5,225 k > Nua [Satisfactory]
w here : f = 0,75 x 0,75 = 0,5625 , ACI 318 17.2.3.4.4
yec,N term is 1.0 for no eccentricity in the connection.
yc,N term is 1.0 for location w here concrete cracking is likely to occur.
CHECK PULLOUT STRENGTH : (ACI 318 17.4.3.1)


f N pn  f ny cp, N Ab8 f 'c  = 12,609 k > Nua [Satisfactory]

w here : f = 0,75 x 0,75 = 0,5625 , ACI 318 17.2.3.4.4


ycp,N term is 1.0 for location w here concrete cracking is likely to occur.
CHECK SIDE-FACE BLOWOUT STRENGTH : (ACI 318 17.4.4.1)
c min > 0.4 hef [Satisfactory]
Since this fastener is located far from a free edge of concrete (c > 0.4 hef ) this type of failure mode is not applicable.
DETERMINE DESIGN TENSILE STRENGTH :

f N n  min f N sa ,f N cb ,f N pn  = 5,225 K

CHECK FASTENER SHEAR STRENGTH : (ACI 318 17.5.1.2)


fV sa  fn0.6 Ase, N f ut = 6,424 k > V ua = 0,535 k [Satisfactory]
w here : f = 0,65 x 1 = 0,65
(for built-up grout pads, first factor shall be multiplied by 0.8, ACI 318 17.5.1.3)
CHECK CONCRETE BREAKOUT STRENGTH FOR SHEAR LOAD : (ACI 318 17.5.1.2) (Cont'd)

fV cbg  f AV y ec ,Vy cd ,Vy c ,VV b  f


1.5c11.5c1  s  c2   c2   l 0.2

y ec ,V  0.7  0.3 y c ,V  7 d  d f c c11.5 
'

    
2
AVo 4.5c1 1.5c1 
= 3,185 k > V ua [Satisfactory]
w here : f = 0,75 x 1 = 0,75
ycp,N term is 1.0 for no eccentricity in the connection.
yc,V term is 1.0 for location w here concrete cracking is likely to occur.
lterm is load bearing length of the anchor for shear, not to exceed 8d.
CHECK PRYOUT STRENGTH FOR SHEAR LOAD : (ACI 318 17.5.3.1)

A No

 hef  
9
0.3 
fV cpg  f k cp A N y ed , Ny c , N N b  f k cp A N2  0.7  c min y c , N 24 f 'c h1.5
1.5h ef 
ef  
= 13,932 k > V ua [Satisfactory]
w here : f = 0,75 x 1 = 0,75
yc,N term is 1.0 for location w here concrete cracking is likely to occur.
kcp = 2,0 for h ef > 2.5 in.
DETERMINE DESIGN SHEAR STRENGTH :

fV n  min fV sa ,fV cb ,fV cp  = 3,185 K

REQUIRED EDGE DISTANCES AND SPACING TO PRECLUDE SPLITTING FAILURE :


Since headed cast-in-place fasteners are not like to be highly torqued, the minimum cover requirements of ACI 318 20.6.1.1 apply.
Cover Prov d > Cover Reqd [Satisfactory]
CHECK TENSION AND SHEAR INTERACTION : (ACI 318 17.6)
Since Nua,1 > 0.2 f Nn and
Vua,1 < 0.2 f V n the full tension design strength is permitted.
The interaction equation must be used

N ua ,1 V ua ,1
  0,41 < 1,2 [Satisfactory]
f N n fV n

Summary of Dimensional Properties of Fasteners


Effective
Fastener Gross Area of Bearing Area of Heads, Nuts, and Washers
Diameter Area of Threaded ( A b ) ( in2 )
( in ) Fastener Fastener Heavy Heavy Hardened
Square Hex
( in2 ) ( in2 ) Square Hex Washers
0,250 1/4 0,049 0,032 0,142 0,201 0,117 0,167 0,258
0,375 3/8 0,110 0,078 0,280 0,362 0,164 0,299 0,408
0,500 1/2 0,196 0,142 0,464 0,569 0,291 0,467 0,690
0,625 5/8 0,307 0,226 0,693 0,822 0,454 0,671 1,046
0,750 3/4 0,442 0,334 0,824 1,121 0,654 0,911 1,252
0,875 7/8 0,601 0,462 1,121 1,465 0,891 1,188 1,804
1,000 1 0,785 0,606 1,465 1,855 1,163 1,501 2,356
1,125 1 1/8 0,994 0,763 1,854 2,291 1,472 1,851 2,982
1,250 1 1/4 1,227 0,969 2,288 2,773 1,817 2,237 3,682
1,375 1 3/8 1,485 1,160 2,769 3,300 2,199 2,659 4,455
1,500 1 1/2 1,767 1,410 3,295 3,873 2,617 3,118 5,301
1,750 1 3/4 2,405 1,900 - - - 4,144 6,541
2,000 2 3,142 2,500 - - - 5,316 7,903