You are on page 1of 1

DESIGN CALCULATION

Project : boutique hotel Structure : 1st floor


Computed by : gks Date : 27-Dec-17 Checked by : gks Date : 27-Dec-17

Cantilever Slab Design

Marking :
P

1000 mm

DL = 15.60 kN/m
LL = 0.50 kN/m

Concrete strength, fcu = 30


30 N/mm 2
Steel tensile strength, f y = 460
460 N/mm 2
Span length, L = 1000 mm
Slab thickness, h = 200 mm
Concrete cover, c = 35 mm
Finishes = 50 mm

Loading ( UDL ) Point Load ( Pt )


Self weight 4.80 kN/m2 Dead load, DL 9.60 kN/m
Finishes 1.20 kN/m2 Live Load, LL 0.00 kN/m
Others 0.00 kN/m2 Ult. Point load, P 13.44 kN/m
Dead load, DL 6.00 kN/m2
Live load
load, LL 0 50
0.50 kN/m2
Ult. Design load, n 9.20 kN/m2

Main Reinforcement Transverse Reinforcement


2
Ult. Design moment, M 18.04 kNm/m Provide Asmin 260 mm /m
Effective depth, d 159 mm Steel bar diameter 1010 mm
K 0.024 Provide T 10 - 200
Lever arm, z 0.950 d Steel area provided, Asprov 393 mm 2/m OK!!
2
Steel area required, Asreq 298 mm /m Shear Capacity
2
Minimum steel area, As min 260 mm /m Ult. Shear force, V 22.64 kN/m
Steel bar diameter 1212 mm Shear stress, v 0.14 N/mm 2
Provide T 12 - 200 Shear capacity, v c 0.60 N/mm 2 OK!!
Steel area provided, Asprov 565 mm 2/m OK!!
Deflection Crack Control
( L / d )basic 7.00 Actual clear spacing 188 mm
2
Service stress, f s 161.7 N/mm Allowable clear spacing 477 mm
M / bd2 0.7 N/mm
2

Tension modification factor 2.00


( L / d )allowable 14.00
( L / d )actual 6.29 OK!!
Shear Force
Dead load, DL 15.60 kN/m
Live load, LL 0.50 kN/m