DESIGN
2 Grade and paving levels and paving extents are shown. (Dimensions of paving
not required.)
5 All equipment nozzles and vendor package terminal points are clearly
identified and tagged.
6 All tie-in points and battery limits are clearly identified and tagged and
coordinates/elevations are indicated.
7 Line numbers identifies all lines and major locating dimensions & elevation are
given.
8 Flow directions and slope symbols are indicated as per the P&IDs.
9 All secondary pipe supports (standard & special) are indicated and tagged and
the locating dimensions marked.
10 All primary pipe supports are identified by appropriate symbols (e.g. guide,
axial stop, etc.).
13 Structural grid numbers of pipe racks, buildings and shelters are shown.
DRAFTING
21 Revision block contains initials of the originator, checker and approver (both
Discipline & Project).
22 Drawing scale is stated in the title block and graphic scale (bar scale) is
shown.
24 All general notes are checked and the units for dimensions, coordinates &
levels are given in the notes.
26 Reference drawing numbers and titles are listed and checked. List shall
include unit plot plan and piping key plan as a minimum.
28 Revision clouds, along with revision number triangles are marked properly, if
applicable.
29 “Hold” clouds, if applicable, are properly marked and the list of “Holds” is
indicated.
30 Key plan is shown and the applicable area/unit of the plot plan is highlighted.
31 Match line co-ordinates and drawing limits are clearly marked and are
consistent with the Key Plan drawing. Continuation drawing numbers are
correctly written.
NCG : GREEN
LPS : RED
FCD : YELLOW
VAP : COLOR 40
SW : COLOR 140
EQUIPMENT : CYAN
TEXT HEIGHT: