You are on page 1of 9

Solution Report For Steel Structures : Practice Test ­ 3

Represent whole test solution with correct and incorrect answers.

  View Your Test Analysis

Q. No Question Status

Q.1 Which one of the statement is FALSE?

a. The structure designed by the plastic method results saving in steel by about 10 – 15%.
b. For indeterminate and complicated structures, the plastic method is more conveniently applicable.
c.  The factor of safety is more in plastic design as compared to elastic design.
d. In plastic design, the lateral bracing requirements are more stringent than the elastic design.

Attempt Correct Correct Ans. c FAQ? Have any doubt? Solution

Q.2 In a gusseted base, when the end of the column is machined for complete bearing on the base plate, the
axial load is assumed to be transferred to the base plate,

a.  fully by direct bearing.
b. fully through the fastenings.
c. 25% by direct bearing and 75% through fastening.
d.  50% by direct bearing and 50% through fastening.

Attempt Incorrect Your Ans. a Correct Ans. d


FAQ? Have any doubt? Solution

Q.3 Equilibrium conditions, yield conditions (M < Mp) and mechanism condition (formation of a plastic collapse

mechanism) are the conditions to be satisfied by any correct plastic analysis result. Which of the above
conditions does the kinematic methods of plastic analysis consider?

a.  Equilibrium and Mechanism condition
b. Equilibrium and Yield condition
c.  Mechanism and Yield condition
d. Only Equilibrium condition

Attempt Incorrect Your Ans. c Correct Ans. a


FAQ? Have any doubt? Solution

Q.4 Which one of the following is not correct for riveted joints as per IS Code?

a.  To minimize the effect of bending in top joints atleast two rivets in a line should be provided.
b. In the case of double cover butt joint, the total shear force to be transmitted by the members is split into two
parts.
c. In the case of double cover butt joint, eccentricity of force does not exist and hence bending is eliminated,
whereas it exists in the case of a lap joint.
d.   Rivets subjected to both shear and axial tension shall be so proportioned that the calculated shear and
axial tension do not exceed τvf and σtf and the expression  does exceed 1.4.

Attempt Incorrect Your Ans. a Correct Ans. d


FAQ? Have any doubt? Solution

Q.5 Which of the following statements are CORRECT ?
1. The single laced systems on opposite sides of the main components should preferably be in the same
direction so that one be the shadow of the other.
2. The angle of inclination of the lacing with the longitudinal axis of the column should be between 40 to 70.
3.  The  lacing  system  should  be  designed  to  resist  additional  shear  due  to  bending  if  the  compression
member carries bending due to eccentric loading, applied end moments, and or lateral loading.

a. 1 and 3
b.  1 and 2
c. 2 and 3
d.  All of the above

Attempt Incorrect Your Ans. b Correct Ans. d


FAQ? Have any doubt? Solution

Q.6 Which of the following statement(s) is(are) CORRECT ?
1. Gusset plate material is saved by using a lug angle but extra material is required for lug angles and their
connection.
2. Lug angles are not very efficient in transmitting loads and a certain eccentricity is caused between the
load and the C.G. of the rivet group.
3. In the case of angle member, the lug angles and their connections to the gusset or any other supporting
member  should  be  capable  of  developing  a  strength  not  less  than  20%  in  excess  of  the  force  in  the
outstanding leg of the angle.

a. 1 and 2
b. 2 and 3
c. only 1
d.  All of the above

Attempt Correct Correct Ans. d FAQ? Have any doubt? Solution

Q.7 For the given shape of the cross­section, which has the largest shape factor ?

a. Rectangular
b.  Triangular
c. Solid circular
d.  Diamond

Attempt Incorrect Your Ans. d Correct Ans. b


FAQ? Have any doubt? Solution

Q.8 For a built up section consisting of two equal angle sections connected back to back and tack riveted along
entire length, the minimum radius of gyration will be along
a.  X ­ X axis
b. Y ­ Y axis
c. 45° to XX and YY axis
d. Can not be ascertained with given data

Attempt Correct Correct Ans. a FAQ? Have any doubt? Solution

Q.9 Number  of  rivets  carrying  calculated  shear  through  a  packing  shall  be  increased  above  the  number
required by normal calculations by ____________ percent for each 2.0 mm thickness of packing except
that, for packing having a thickness of 6 mm or less, no increment need to be made.

Attempt Incorrect Your Ans. 25 Correct Ans. 2.5


FAQ? Have any doubt? Solution

Q.10 The  permissible  stresses  for  main  structural  steel  members  under  dynamic  loads  should  be  increased
by____________ %.

Attempt Incorrect Your Ans. 25 Correct Ans. 33.33 (33 ­ 34)


FAQ? Have any doubt? Solution

Q.11 A  simply  supported  beam  of  span  5000  mm  is  loaded  with  a  uniformity  distributed  load  of  40  kN/m.

Assuming yield strength of steel, fy  = 250 MPa, required section modulus is ____________ cm3 .

[Use WSM]

Attempt Incorrect Your Ans. 833.33 Correct Ans. 757.58 (755­760)


FAQ? Have any doubt? Solution

Q.12 For a diamond section, shape factor is 2. The factor of safety in bending is 1.5. If the allowable stress is
increased by 25% for wind and earthquake loads, then the load factor is ____________.

Attempt Correct Correct Ans. 2.4 FAQ? Have any doubt? Solution

Q.13 The ratio of shear carrying capacity of a rivet in a double cover butt joint to that of a rivet in a lap joint,
would be ____________.
Attempt Correct Correct Ans. 2 FAQ? Have any doubt? Solution

Q.14 A 12 mm thick­bracket plate is used to transmit a reaction of 125 kN (factored load) at an eccentricity of
75  mm  from  the  column  flange.  If  depth  of  column  is  150  mm,  then  the  bending  stress  developed  will

be____________ N/mm2 .

Not Attempt Correct Ans. 208.33 (205 ­ 210) FAQ? Have any doubt? Solution

Q.15 For a welded plate girder with vertical stiffeners, the maximum depth of web provision in design when the
thickness of the web plate is 8 mm, would be ____________ mm.

Attempt Correct Correct Ans. 1600 FAQ? Have any doubt? Solution

Q.16 A  steel  column  pinned  at  both  ends  has  a  buckling  load  of  160  kN.  If  the  column  is  effectively  held  in
position  and  restrained  against  rotation  at  one  end  but  neither  held  in  position  nor  restrained  against
rotation at the other end, then its buckling load will be ____________ kN.

Attempt Correct Correct Ans. 40 FAQ? Have any doubt? Solution

Q.17
A fixed ended beam is subjected to load W at 1/3rd span as shown in figure. The collapse load is

                       

a. 

b.   

c. 

d. 

Attempt Correct Correct Ans. b FAQ? Have any doubt? Solution

Q.18 A moment M of magnitude 100 kN­m is transmitted to a column flange through a bracket by using four 16
mm diameter rivets as shown in figure.
                        
The shear force (in kN) in rivet A is

a.  176.78
b. 218.36
c. 333.56
d. 436.72

Attempt Correct Correct Ans. a FAQ? Have any doubt? Solution

Q.19 When  less  number  of  high  strength  bolts  are  used  for  making  the  connection  with  smaller  connection
length, which of the following type of failure occurs

a. yielding of gross­section
b. rupture failure
c. tearing failuire of plate
d.  block shear failure

Attempt Correct Correct Ans. d FAQ? Have any doubt? Solution

Q.20 Which one of the following statement(s) is(are) true about load factor in plastic analysis and design of steel
structure?
1.  In  actual  practice,  a  load  factor  varying  from  1.7  to  2.0  is  assumed  depending  upon  the  designer’s
judgement.
2. When the structure is subjected to wind, the corresponding load factor for plastic analysis is increased
by 25%.
3. The prime function of the load factor is to ensure that the structure will be safe under service conditions.

a. only 1
b.  2 and 3
c.  1 and 3
d. All of the above

Attempt Incorrect Your Ans. b Correct Ans. c


FAQ? Have any doubt? Solution

Q.21
A square steel slab base of area 4 m2  is provided for a column made of two rolled channel sections. The
500  mm  ×  250  mm  column  carries  an  axial  compressive  load  of  2500  kN.  The  line  of  action  of  the  load
passes through the centroid of the column section as well as of the slab base. The permissible bending
stress in the slab base is 185 MPa. The required minimum thickness (in mm) of the slab base is
a. 54.03
b. 76.80
c.  79.59
d. 68.39

Attempt Correct Correct Ans. c FAQ? Have any doubt? Solution

Q.22 Two plates, subjected to direct tension, each of 12 mm thickness and having widths of 130 mm and 150
mm, respectively are to be fillet welded with an overlap of 300 mm. Given that the permissible stress is
110 MPa and the permissible stress in steel is 150 MPa. The length of the weld required using the minimum
permissible weld size (in mm) as per IS 800:1984 is

a. 832.27
b.  607.79
c. 492.64
d. 370.57

Attempt Correct Correct Ans. b FAQ? Have any doubt? Solution

Q.23 A prismatic beam (as shown below) has plastic moment capacity of MP, then the collapse load P of the

beam is

                    

a.   

b. 

c. 

d. 

Attempt Correct Correct Ans. a FAQ? Have any doubt? Solution

Q.24 A double cover riveted butt joint is used to connect two plates of 250 mm width and 16 mm thickness as
shown  in  figure.  There  are  sixteen  power  driven  rivets  of  20  mm  diameter  at  a  pitch  of  75  mm  in  both
direction on either side of the plate. Two cover plates of 10 mm thickness are used. The capacity (in kN) of
the joint in tension considering bearing and shear only, with permissible bearing and shear stresses as
300 MPa and 100 MPa respectively, is

                         

a. 978.26
b. 1012.23
c.  1161.76
d. 1373.49

Attempt Correct Correct Ans. c FAQ? Have any doubt? Solution

Q.25 A  column  consists  of  four  ISA  150  ×  150  ×  12  mm,  riveted  together  as  shown  in  figure.  If  the  effective
length of column is 4.5 m, then the slenderness ratio is _____________.

                                    

Attempt Incorrect Your Ans. 97.59 Correct Ans. 72.62 (70 ­ 75)


FAQ? Have any doubt? Solution

Q.26 The  minimum  thickness  of  lacing  flat  required  for  single  lacing  system  as  compared  to  double  lacing
system is _________ times for same effective length of lacings under identical condition.

Attempt Correct Correct Ans. 1.5 FAQ? Have any doubt? Solution

Q.27 A bracket plate is welded to a column flange through a fillet weld of size 8 mm. It is subjected to a 110 kN
load acting at an eccentricity of 220 mm from the C.G. of the weld as shown in figure below.
The direct shear stress acting on the weld group is ______________ N/mm2 .

Attempt Correct Correct Ans. 29.76 (29 ­ 30) FAQ? Have any doubt? Solution

Q.28 A section is said to be plastic when outstand of compression flange is less than _____________ ε.

Attempt Correct Correct Ans. 9.4 FAQ? Have any doubt? Solution

Q.29 A plate section, 300 mm × 10 mm has four staggered holes as shown in figure. The diameter of hole is 21.5
mm. The allowable axial tension will be _________ kN.

[Take permissible stress of 150 N/mm2  in axial tension]

                  

Attempt Correct Correct Ans. 345 (342 ­ 348) FAQ? Have any doubt? Solution

Q.30 The magnitude of load P is increased till collapse and the plastic moment carrying capacity of steel beam
section is 120 kNm. The value of R using plastic analysis is _______ kN.

                              
Attempt Correct Correct Ans. 60 FAQ? Have any doubt? Solution

Q.31 Two plates of thickness 16 mm and 14 mm are to be jointed by a single ­V groove weld as shown in figure.

            
Assuming an effective length of 200 mm, Fe 410 grade steel plates are used and that the welds are shop
welded. The strength of weld is __________ kN.
[Assume factor of safety γmw = 1.25]

Attempt Correct Correct Ans. 350 FAQ? Have any doubt? Solution

Q.32 A  diamond  section  with  unequal  diagonals,  the  shorter  being  b  and  longer  h,  is  used  as  a  beam.  If  the
shorter diagonal is placed parallel to the xx ­ axis, the shape factor of the section will be __________.

Attempt Correct Correct Ans. 2 FAQ? Have any doubt? Solution

Q.33 If a built­up single laced column is subjected to 1200 kN axially and inclination of the lacing bar is 45° with
vertical, then each lacing bar is designed for an axial force of ____________kN.

Attempt Correct Correct Ans. 21.21 (21 ­ 22) FAQ? Have any doubt? Solution

You might also like