TurPower Associates Application Note #106

Why update older


Why older,, analog panel meters?
meters?

It is easier and more affordable than ever to re-


place older, outdated single-function analog meters,
such as voltage, current, or frequency meters, with
newer, digital technology. As you know traditional
style analog meters are subject to interpretation er-
ror when the technician tries to determine the read-
ing according to the needle on the display. Not to
mention, that this style of meter must be read onsite.
Newer style digital meters offer many advantages. PM130 Series TrueMeterTM from SA
from TEC
SATEC

Feeder Conditions Instantly & Accuratel


Instantly y
Accurately MODBUS or DNP 3.0 protocols) to determine what
The PM130 Series TrueM TM
Meter from SATEC si- information is communicated, so the “data highway”
multaneously displays phases A, B, and C on a digi- does not get bogged down with unneeded data.
tal readout that provides exact readings. Because Fits StandardP
Standard anel Cutout
Panel
all three phases are viewed at the same time, the
technician can instantly determine feeder condition The PM130 Series directly replaces existing
and balance. ANSI 4” round style switchboard meters or a 92 X
92 mm DIN square system meter cutout. The unit is
With a touch of a button, the PM130 Meters will constructed in a rugged, molded housing and fits in
display additional information, such as min/max the same cutout - no panel alteration is required.
measurements (instantaneous and demands), real The PM130 Series meets IEEE C37.90.1 surge with-
time measurements, four quadrant readings (power standing capacity, ANSI C62.41-1991 standard
and power factor), and status information on relays, surge standards, and more.
counters, and TXD, RXD communications. The
PM130 Series provides True RMS measurement and The units feature a unique “pass thru” rear cur-
fast, real-time, cycle-by-cycle measurements at 32 rent CT input for easy connection and low burden.
samples per cycle. The units have an LED percent- The unique design offers system protection and/or
of-load bar that mimics the analog meter needle. redundancy.
System Integration of the Old With the New
New Not only are the meters affordable but one meter
replaces multiple analog meters. The PM130 re-
By replacing older analog meters with the PM130 places 14 analog meters, the PM130P power model
Series TrueMMeterTM, you can easily integrate them replaces up to 42 analog meters , and the PM130E
with Energy Management or SCADA systems in- energy model replaces up to 56 analog meters.
cluding MODBUS, ASCII, or DNP 3.0. By updating
and integrating older, analog meters, electrical pa- Call TruPower Associates for more on just how
rameters can be viewed and controlled remotely, as easy and affordable it is to provide your power sys-
well as adding remote alarm capabilities. The as- tem with so much more by replacing analog meters
signable registers feature allows the user (via with PM130 Series TrueM MeterTM panel meters.