You are on page 1of 6

PRECA SOLUTIONS INDIA PVT. LTD.

Regd. Office : Plot # 6, D No.2-9/5/6, Venkata Sai Gateway


Green Land colony, Gachibowli, Hyderabad - 500032.

Main tensile bar

d/2

Width of Corbel = 750 mm


Total thickness of Corbel, h = 500 mm
Clear cover = 40 mm
Depth to main reinforcement = 460 mm

Yield strength of reinforcement, Fy = 500 Mpa


Compressive strength of concrete, Fck = 40 Mpa
Type of concrete = Normal weight
λ = 1
Corbal construction = 1
Coefficient of friction, μ = 1.4

Factored vertical load, Vu = 2050 Kn


Distance of vertical load from face of column, a = 125 mm
Horizontal force acting on corbel, Nuc = 410 Kn
Strength reduction factor (as per 11.9.3.1), φ = 0.8

Nominal vertical load, Vn=Vu/φ = 2562.50 Kn


Nominal vertical load capacity, Vn-cap=0.2*Fck*b*d = 2760.00 Kn
also check for 5.5*b*d & take minimum of both as Vn 1897.5 KN
So consider Vnc as min of above = 1897.5 kN
Shear friction reinforcement
Minimum horizontal force acting on corbel,Nuc-min= 0.2xVu = 410.00 Kn
Horizontal force acting on corbel = 410.00 Kn
Area of shear friction reinforcement, Avf=Vn/(Fyxμ) = 3660.71 Sq mm
for balanced conditions, j = 0.85
Af= [(Vuxa)+(Nuc-actx(h-d)]/(Φxfyxjxd) = 1743.29 Sq mm
Nominal area required, An=Nuc-act/(φ*Fy) = 1025.00 Sq mm
Minimum area of tensile reinforcement
Asc-min=0.04xFckxbxd/Fy = 1104.00 Sq mm
Area of tensile reinforcement Asc = 3465.48 Sq mm
Area of tensile reinforcement required, Asc-req = 3465.48 Sq mm
Dia of main tensile reinforcement, D = 20 mm
Dia of each bar = 628.32 Sq mm
No. of bars required = 6
Provide no. of bars = 7
Area of tensile reinforcement provided = 4398 Sq mm

Horizontal reinforcement
Minimum area of horizontal reinforcement,
Ah-min= 0.5x(Asc-req-An) = 1220 Sq mm
Area of horizontal reinforcemen required
max(Avf/3 and Af/2) = 1220 Sq mm
Area of horizontal reinforcemen required = 1220 Sq mm
Dia if horizontal reinforcement = 12 mm
Area of each bar = 226 Sq mm
Number of bars required = 6
Area of horizontal reinforcement provided = 1357

Spacing of horizontal reinforcement = 51 mm


Say 100 mm
Design Summary
Provide Corbel 750 wide and 500 deep
provi 7 no.20mm dia bars as main reinforcement
provi 6 no.12mm dia bars at 100 mm c/c as horizontal reinforcement

Vu =2050 Kn
125 mm
7 No.- Y20 mm dia
Nuc=410 Kn

hc>=d/2

h=500 mm

d=460 mm 6 No.- Y12 mm dia at 100 C/C


ONS INDIA PVT. LTD.
No.2-9/5/6, Venkata Sai Gateway
hibowli, Hyderabad - 500032.

ACI-11.9.3.1

ACI-11.9.3.2.1
safe

ACI-11.9.3.4
ACI-11.7.4.1

ACI-11.9.3.3
ACI-11.9.3.4
ACI-11.9.5
ACI-11.9.3.5

safe

ACI-11.9.4

ACI-11.9.3.5 a & b

safe