You are on page 1of 75

DISEÑO SISMO RESISTENTE

PROYECTO FINAL: DISEÑO ESTRUCTURAL VIVIENA MULTIFAMILIAR EN EL

CASCO URBANO DEL MUNICIPIO DE SEMANIEGO - NARIÑO

ALUMNOS:

JAIRO ANDRES GONZALEZ SANTACRUZ

IVAN DARIO JURADO MELO

INGENIERO:

ALFER SILVA CERÒN

UNIVERSIDAD DEL CAUCA

ESPECIALIZACIÒN EN ESTRUCTURAS

FACULTAD DE INGENIERIA CIVIL

POPAYAN – 2018
1
TABLA DE CONTENIDO

INTRODUCCION .............................................................................................................................3
1. OBJETIVOS .............................................................................................................................3
1.1. Objetivo general .............................................................................................................3
2. ANÁLISIS DE ENTRADA GENERAL. .................................................................................4
3. ANÀLISIS DE CARGAS ........................................................................................................7
4. PREDIMENSIONAMIENTO DE ELEMENTOS ESTRUCTURALES .............................12
5. ANÁLISIS ESTÁTICO Y MODAL DE LA ESTRUCTURA ..............................................14
6. CALCULO DE IRREGULARIDADES ................................................................................21
7. DISEÑO DE COLUMNAS ....................................................................................................24
7.1. Diseño a Cortante de columnas C1 y C2 ...............................................................30
8. DISEÑO DE VIGAS ..............................................................................................................36
8.1. Diseño por cortante ....................................................................................................46
9. DISEÑO LOSA DE ENTREPISO ........................................................................................48
9.1. Diseño de vigas auxiliares ........................................................................................50
10. DISEÑO DE CIMENTACIÓN ...........................................................................................54
10.1. Viga de cimentación................................................................................................60
11. LONGITUD DE DESARROLLOS Y GANCHOS PARA LOS ELEMENTOS
ESTRUCTURALES ......................................................................................................................64
12. DISEÑO DE ELEMENTOS NO ESTRUCTURALES ...................................................65
13. REQUISITOS PROTECCIÓN CONTRA INCENDIOS. ................................................72
14. CONCLUSIONES ..............................................................................................................75

2
INTRODUCCION

En este trabajo se presenta una descripción detallada del diseño estructural para la

construcción de la vivienda multifamiliar ubicada en el casco urbano del municipio

de Samaniego – Nariño. El diseño estructural parte de los planos arquitectónicos

definitivos y del estudio de suelo realizado por el grupo CONSULTORES Y

CONSTRUCTORES SAS; con esta información preliminar se presenta y se discute

los resultados obtenidos y se dan las conclusiones y recomendaciones pertinentes

para garantizar la estabilidad y la seguridad de las obras proyectadas en los

aspectos relativos al dimensionamiento y diseño de columnas, vigas, losas y la

respectiva cimentación teniendo en cuenta los parámetros normativos vigentes

NSR-10 de Colombia.

1. OBJETIVOS

En el siguiente trabajo se plantean los siguientes objetivos:

1.1. Objetivo general

Realizar el diseño estructural de la vivienda multifamiliar en el casco urbano del

municipio de Samaniego – Nariño.

3
DISEÑO ESTRUCTURAL VIVIENA MULTIFAMILIAR EN EL CASCO

URBANO DEL MUNICIPIO DE SEMANIEGO - NARIÑO

2. ANÁLISIS DE ENTRADA GENERAL.

PROYECTO EDIFICIO MULTIFAMILIAR SAMANIEGO

DATOS INICIALES
NOMBRE DEL PROYECTO DISEÑO ESTRUCTURAL VIVIENDA MULTIFAMILIAR EN EL CASCO URBANO DE SAMANIEGO
DEPARTAMENTO NARIÑO
UBICACIÓN DE LA
MUNICIPIO SAMANIEGO
EDIFICACION
DIRECCIÓN BARRIO INDUSTRIAL
ZONA DE AMENAZA SISMICA ALTA
REGION DE AMENAZA SISMICA PARA Aa 6.0
COEF. DE ACELERACION PICO EFECTIVA (Aa) 0.3
REGION DE AMENAZA SISMICA PARA Av 6.0
COEF. DE VELOCIDAD PICO EFECTIVA (Av) 0.3
TIPO DE USO DE LA EDIFICACION RESIDENCIAL
GRUPO DE IMPORTANCIA (I) ESTRUCTURA DE OCUPACION NORMAL
COEFICIENTE DE IMPORTANCIA (I) 1.0
COEFICIENTE Fa 1.2
COEFICIENTE Fv 1.8
PORTICOS RESISTENTES A MOMENTOS DE CONCRETO
TIPO DE ESTRUCTURA
REFORZADO
ALTURA DE LA EDIFICACION 15.1

Planta típica de entrepiso.

4
 Modelo generado en ETABS.

 Número de pisos: 5 pisos

 Altura total por piso: 3 m

 Columnas: 30 cm x 30 cm

 Vigas 30 cm x 50 cm

 Materiales

E Unit Weight
Material ν Design Strengths
kN/m² kN/m³
acero refuerzo 200000000 0.3 76.9729 Fy=420000 kN/m², Fu=620528.21 kN/m²
conc. 3000 psi 21000000 0.2 23.5631 Fc=21000 kN/m²

5
 Factores de Carga

Self Weight
Carga Tipo
Multiplier
Dead Dead 1
Live Live 0
Super Dead Superimposed Dead 0
Roof Live Roof Live 0
Wind Wind 0
Seismic Seismic 0

 Espectro elástico y de diseño para el edificio multifamiliar Samaniego.

ESPECTRO ELÁSTICO E INELÁSTICO DE DISEÑO


1.3
1.2
1.1
1.0
0.9 _______________ Espectro Elástico de Diseño
0.8
0.7
_______________ Espectro Inelástico de Diseño
Sa (%g)

0.6
0.5
0.4
0.3
0.2
0.1
0.0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
PERIODO T (Sg)

6
3. ANÀLISIS DE CARGAS

 Carga Muerta (D)

SUPER DEAD ENTREPISO N/m2 KN/m2


cielo raso 250 0.25
cerámica + afinado de piso 1100 1.1
muros divisorios 3000 3
Total 4350 4.35

Carga Loseta 2400 2.4


Área Loseta (m2) 51
TOTAL SUPERDEAD 6750 6.75
TOTAL SUPERDEAD (KN) 344.25

CARGAS ENTREPISO
COLUMNAS N KN
PISO 1
45X55 114345 114.345
Total 114345 114.345

PISO 2 N KN
45X55 103950 103.95
Total 103950 103.95

PISO 3 N KN
45X55 103950 103.95
Total 103950 103.95

PISO 4 N KN
45X55 75141 75.141
30X30 9936 9.936
Total 85077 85.077

PISO 5 N KN
45X55 15444 15.444
30X30 2808 2.808
Total 18252 18.252

7
VIGAS LONG PESO
PARA TODOS LOS PISOS N KN
35X50 31.14 130788 130.788
15X50 15.23 27414 27.414
IPE 17.04 3220.56 3.220
Total 161422 161.422

SUPER DEAD CUBIERTA N/m2 KN/m2


cielo raso 250 0.25
Total 250 0.25

Carga Loseta 2400 2.4


Área Loseta (m2) 34
TOTAL SUPERDEAD 2650 2.65
TOTAL SUPERDEAD (KN) 90.1

VIGAS CUBIERTA LONG N KN


25X30 33.31 59958 59.958
15X30 4.14 4471 4.471
Total 64429 64.429

PESO POR PISO


PISO PESO
5 172.8
4 590.7
3 609.6
2 609.6
1 620.0
TOTAL 2602.8

 Caga Viva (L)

KN/M2 PESO TOTAL KN


ENTREPISO 1.8 91.8
CUBIERTA 1.8 61.2

8
 Fuerzas de viento.

Características del edificio

 Cubierta losa maciza

 Pendiente cubierta: 2%

 Edificio con una puerta de 1.0 x 2.2m, una cortina de 2.5 x 2.2m y 4

ventanas de 2 x 1.4m en la fachada frontal; con dos puerta-cortinas de 2.1 x

2.2m y 8 ventanas de 2 x 1.4m en la fachada posterior.

 Altura del edificio: 15.1 m

Requisitos para el uso del método analítico

 El edificio es de forma regular

 El edificio no tiene características de respuesta que den lugar a cargas

transversales de viento, generación de vórtices, inestabilidad debida a

golpeteo o aleteo y que por su ubicación, tampoco deben merecer

consideración especial los efectos de canalización o sacudimiento por la

estela producida por las obstrucciones a barlovento.

Velocidad de Viento (V) y Factor de direccionalidad del viento (Kd)

 Ubicación del edificio, Samaniego- Nariño Zona 3

 V= 28 m/s (100 km/h) Figura B.6.4-1

 Kd= 0.85 Tabla B.6.5-4

Factor de importancia (I) y coeficiente de exposición (Kz)

9
 Grupo I: Estructuras de ocupación normal

 I= 0.87 Tabla B.6.5-1

 Rugosidad del terreno: Categoría B, área urbana.

 Categoría de exposición: Exposición B

 Kh= 0.81 Tabla B.6.5-3

Factor topográfico Kzt

 Ubicación zona urbana, terreno plano.

 Kzt= 1

Factor de ráfaga G

 G= 0.85

Clasificación del cerramiento

Frontal Posterior
Area Fachada
71.73 107.36
Ag
0.8 Ag = 57.38 85.89
Puertas 7.7 11
ventanas 11.2 22.4
Aberturas Ao 18.9 33.4
Ao <= 0.8 Ag
Ao > 0.37 m2
Ao <= 0.8 Ag
Edificio parcialmente cerrado

Coeficiente de presión interna GCpi

𝐺𝐶𝑝𝑖 = ±0.55

10
Determinación de qh

𝑞ℎ = 0.613 ∗ 𝐾𝑍 𝐾𝑍𝑇 𝐾𝑑 𝑉 2 𝐼

𝑞ℎ = 0.613 ∗ 0.81 ∗ 1 ∗ 0.85 ∗ 282 ∗ 0.87 = 288 𝑁/𝑚2

Coeficiente de presión externa GCp

𝐺𝐶𝑝 = −0.43

Determinación de la carga de viento B.6.5.12.2.2

𝑃 = 𝑞ℎ ∗ (𝐺𝐶𝑝 − 𝐺𝐶𝑝𝑖 )

𝑃𝑚𝑎𝑥 = 288 ∗ (−0.43 − 0.55) = −282 𝑁/𝑚2

En B.6.1.3.1 la carga de viento mínima es de 400 N/m2

𝑃𝑚𝑎𝑥 = 400 𝑁/𝑚2

Fuerzas de Viento 400 N/m2


PISO Fuerza Viento KN
5 3.6972
4 7.9632
3 8.532
2 8.532
1 9.243
TOTAL 37.967

11
4. PREDIMENSIONAMIENTO DE ELEMENTOS ESTRUCTURALES

 Columnas

C.21.61.1. La dimensión menor de la sección transversal no debe ser menor de

300mm.

𝐶𝑜𝑙𝑢𝑚𝑛𝑎𝑠: 30𝑐𝑚 𝑥 30𝑐𝑚.

𝐶𝑜𝑙𝑢𝑚𝑛𝑎𝑠 𝑠𝑢𝑚𝑖𝑛𝑖𝑠𝑡𝑟𝑎𝑑𝑎: 45𝑐𝑚 𝑥 45𝑐𝑚.

 Vigas

Tabla CR.9.5, altura mínima recomendada para vigas que soporten muros divisorios

y particiones frágiles.

𝑙 5.9 𝑚
𝑉𝑖𝑔𝑎 𝑠𝑖𝑚𝑝𝑙𝑒𝑚𝑒𝑛𝑡𝑒 𝑎𝑝𝑜𝑦𝑎𝑑𝑎𝑠 ℎ = = = 0.53 𝑚
11 11

𝐴𝑙𝑡𝑢𝑟𝑎 𝑠𝑢𝑚𝑖𝑑𝑎 ℎ = 0.50 𝑚

C.21.5.1.3. El ancho del elemento, bw, no debe ser menor que el más pequeño de

0.3 h y 250 mm.

𝐴𝑛𝑐ℎ𝑜 𝑚𝑖𝑛𝑖𝑚𝑜 𝑏𝑤 = 0.25 𝑚

𝐴𝑛𝑐ℎ𝑜 𝑎𝑠𝑢𝑚𝑖𝑑𝑜 𝑏𝑤 = 0.35 𝑚

 Losa de entrepiso

Tabla CR.9.5, espesor mínimo losa maciza en una dirección

12
𝑙 5.32 𝑚
𝐿𝑜𝑠𝑎 𝑚𝑎𝑐𝑖𝑧𝑎 𝑒 = = = 0.266 𝑚
20 20

Se opta por colocar vigas auxiliares con el fin de obtener luces menores 1.77 m

𝑙 1.77 𝑚
𝐿𝑜𝑠𝑎 𝑚𝑎𝑐𝑖𝑧𝑎 𝑒 = = = 0.08 𝑚
20 20

𝐸𝑠𝑝𝑒𝑠𝑜𝑟 𝑠𝑢𝑚𝑖𝑛𝑖𝑠𝑡𝑟𝑎𝑑𝑜 𝑒 = 10 𝑐𝑚

13
5. ANÁLISIS ESTÁTICO Y MODAL DE LA ESTRUCTURA

 Método de las fuerzas horizontales equivalentes.

Vs=Sa*∑W
Sa (%g) 0.9 2342.51
(KN)
Ta= Cthα (Sg) 0.54 Ct 0.047
h (m) 15.1
α 0.9
k 1.02

Peso W Altura h
Piso Whk Cvx=Whk/∑Whk Fx= CvxVs Vx (KN)
(KN) (m)
5 172.8 15.1 2758.21211 0.12 281.61 281.61
4 590.7 12.5 7776.53813 0.34 793.98 1075.59
3 609.6 9.5 6064.789 0.26 619.21 1694.80
2 609.6 6.5 4117.45543 0.18 420.39 2115.19
1 620.0 3.5 2226.47898 0.10 227.32 2342.51
∑ 2602.8 ∑: 22943.4736 1.00 2342.51

Cortante basal estático:

𝑉𝐸𝑆𝑇𝐴𝑇𝐼𝐶𝑂 = 2342.51 𝐾𝑁

Cortante basal estático de ETABS

TABLE: Story Response


Elevation X-Dir Y-Dir
Story Location
m kN kN
Story5 15.1 Top 295.9 295.9
Story4 12.5 Top 740.5 740.5
Story3 9.5 Top 601.0 601.0
Story2 6.5 Top 408.1 408.1
Story1 3.5 Top 220.6 220.6
Base total 0 Top 2248.2 2248.2

14
𝑉𝐸𝑆𝑇𝐴𝑇𝐼𝐶𝑂 = 2248.2 𝐾𝑁

 Chequeo de derivas modelo inicial

TABLE: Story Drifts


X Y Z
Story Load Case/Combo Direction Drift Label
m m m
Story5 Envolvente Max X 0.0045 16 4.49 9.92 15.1
Story5 Envolvente Max Y 0.0039 2 6.29 5.32 15.1
Story4 Envolvente Max X 0.0108 16 4.49 9.92 12.5
Story4 Envolvente Max Y 0.0104 14 6.29 -0.8 12.5
Story3 Envolvente Max X 0.0158 16 4.49 9.92 9.5
Story3 Envolvente Max Y 0.0163 14 6.29 -0.8 9.5
Story2 Envolvente Max X 0.0196 16 4.49 9.92 6.5
Story2 Envolvente Max Y 0.0206 14 6.29 -0.8 6.5
Story1 Envolvente Max X 0.0224 7 4.49 8.92 3.5
Story1 Envolvente Max Y 0.0234 1 6.29 0 3.5

Diagrama de derivas

𝐷𝑒𝑟𝑖𝑣𝑎 𝑚𝑎𝑥 𝑒𝑛 𝑑𝑖𝑟𝑒𝑐𝑐𝑖𝑜𝑛 𝑥 = 2.2%

𝐷𝑒𝑟𝑖𝑣𝑎 𝑚𝑎𝑥 𝑒𝑛 𝑑𝑖𝑟𝑒𝑐𝑐𝑖𝑜𝑛 𝑦 = 2.3%

Derivas superiores al 1%,

NO CUMPLE

15
 Periodos y frecuencias modales

TABLE: Modal Periods and Frequencies


Period Frequency Circular Frequency Eigenvalue
Case Mode
sec cyc/sec rad/sec rad²/sec²
Modal 1 0.843 1.186 7.4523 55.5361
Modal 2 0.819 1.221 7.6687 58.8082
Modal 3 0.744 1.345 8.4501 71.4044
Modal 4 0.276 3.625 22.778 518.8371
Modal 5 0.271 3.696 23.2252 539.4104
Modal 6 0.247 4.055 25.4791 649.184
Modal 7 0.162 6.183 38.8496 1509.292
Modal 8 0.16 6.252 39.2806 1542.9632
Modal 9 0.15 6.689 42.0272 1766.2846
Modal 10 0.123 8.155 51.2406 2625.5946
Modal 11 0.12 8.311 52.2223 2727.1668
Modal 12 0.114 8.801 55.3011 3058.2112

Chequeo del periodo

𝑇 ≤ 𝐶𝑢 ∗ 𝑇𝑎

0.843 ≤ 1.2 ∗ 0.54

0.843 ≤ 0.648 𝑁𝑂 𝑂𝐾

El periodo no cumple con los requisitos de la norma, la estructura es muy flexible y

presenta desplazamientos excesivos. Utilizando el software ETABS se comenzó a

incrementar las secciones teniendo en cuenta el plano arquitectónico para lograr el

cumplimiento de derivas, y se obtuvo los siguientes resultados:

𝐶𝑜𝑙𝑢𝑚𝑛𝑎𝑠: 45 𝑐𝑚 𝑥 45 𝑐𝑚

𝑉𝑖𝑔𝑎𝑠: 35 𝑐𝑚 𝑥 50 𝑐𝑚

16
 Materiales

E Unit Weight
Material ν Design Strengths
kN/m² kN/m³
acero refuerzo 200000000 0.3 76.9729 Fy=420000 kN/m², Fu=620528.21 kN/m²
conc. 4000 psi 24870062 0.2 23.5631 Fc=28000 kN/m²

 Periodos y frecuencias modales

TABLE: Modal Periods and Frequencies


Period Frequency Circular Frequency Eigenvalue
Case Mode
sec cyc/sec rad/sec rad²/sec²
Modal 1 0.502 1.994 12.528 156.956
Modal 2 0.456 2.194 13.787 190.081
Modal 3 0.355 2.819 17.715 313.824
Modal 4 0.154 6.495 40.809 1665.401
Modal 5 0.144 6.965 43.761 1914.989

17
TABLE: Modal Periods and Frequencies
Period Frequency Circular Frequency Eigenvalue
Case Mode
sec cyc/sec rad/sec rad²/sec²
Modal 6 0.115 8.676 54.510 2971.387
Modal 7 0.091 10.935 68.704 4720.238
Modal 8 0.084 11.850 74.453 5543.217
Modal 9 0.072 13.823 86.855 7543.859
Modal 10 0.061 16.499 103.664 10746.238
Modal 11 0.058 17.136 107.672 11593.201
Modal 12 0.051 19.643 123.421 15232.740

Chequeo del periodo

𝑇 ≤ 𝐶𝑢 ∗ 𝑇𝑎

0.502 ≤ 1.2 ∗ 0.54

0.502 ≤ 0.648 𝑂𝐾

 Chequeo de derivas modelo inicial

TABLE: Story Drifts


Story Load Case/Combo Direction Drift Label X (m) Y (m) Z (m)
Story5 Envolvente Max X 0.0045 16 4.49 9.92 15.1
Story5 Envolvente Max Y 0.0039 2 6.29 5.32 15.1
Story4 Envolvente Max X 0.0052 16 4.49 9.92 12.5
Story4 Envolvente Max Y 0.0053 14 6.29 -0.8 12.5
Story3 Envolvente Max X 0.0074 16 4.49 9.92 9.5
Story3 Envolvente Max Y 0.0080 14 6.29 -0.8 9.5
Story2 Envolvente Max X 0.0088 16 4.49 9.92 6.5
Story2 Envolvente Max Y 0.0096 14 6.29 -0.8 6.5
Story1 Envolvente Max X 0.0071 7 4.49 8.92 3.5
Story1 Envolvente Max Y 0.0077 2 6.29 5.32 3.5

18
𝐷𝑒𝑟𝑖𝑣𝑎 𝑚𝑎𝑥 𝑒𝑛 𝑑𝑖𝑟𝑒𝑐𝑐𝑖𝑜𝑛 𝑥 = 0.88%

𝐷𝑒𝑟𝑖𝑣𝑎 𝑚𝑎𝑥 𝑒𝑛 𝑑𝑖𝑟𝑒𝑐𝑐𝑖𝑜𝑛 𝑦 = 0.96%

Derivas menores al 1%,

CUMPLE

 Masa modal efectiva

TABLE: Modal Participating Mass Ratios


Case Mode Period [seg] UX UY Sum UX Sum UY
Modal 1 0.502 0.157 0.557 0.157 0.557
Modal 2 0.456 0.632 0.215 0.789 0.772
Modal 3 0.355 0.061 0.084 0.850 0.857
Modal 4 0.154 0.060 0.028 0.910 0.884
Modal 5 0.144 0.033 0.065 0.943 0.949
Modal 6 0.115 0.004 0.009 0.947 0.958
Modal 7 0.091 0.030 0.000 0.977 0.958
Modal 8 0.084 0.001 0.021 0.978 0.979
Modal 9 0.072 0.003 0.007 0.980 0.986
Modal 10 0.061 0.014 0.000 0.994 0.986
Modal 11 0.058 0.001 0.010 0.995 0.996
Modal 12 0.051 0.001 0.001 0.996 0.997

19
Con 12 modos se logra una participación de la masa del 99.6%, superior al 90%

exigido para estructuras irregulares. Teniendo en cuenta esto, el método de fuerza

horizontal equivalente que solo tiene en cuenta los dos primeros modos, no es

suficiente para representar el comportamiento de la masa de la estructura.

 Cortante basal dinámico

TABLE: Story Response


Elevation X-Dir Y-Dir X-Dir Min Y-Dir Min
Story Location
m kN kN kN kN
Story5 15.1 Top 275.9 258.0 -275.9 -258.0
Bottom 275.9 258.0 -275.9 -258.0
Story4 12.5 Top 889.3 882.0 -889.3 -882.0
Bottom 889.3 882.0 -889.3 -882.0
Story3 9.5 Top 1425.5 1424.1 -1425.5 -1424.1
Bottom 1425.5 1424.1 -1425.5 -1424.1
Story2 6.5 Top 1814.0 1813.6 -1814.0 -1813.6
Bottom 1814.0 1813.6 -1814.0 -1813.6
Story1 3.5 Top 2028.2 2023.7 -2028.2 -2023.7
Bottom 2028.2 2023.7 -2028.2 -2023.7

 Chequeo Cortante dinámico

𝑉𝐷𝐼𝑁𝐴𝑀𝐼𝐶𝑂 = 2023.7 𝐾𝑁

𝑉𝐷𝐼𝑁𝐴𝑀𝐼𝐶𝑂 ≥ 0.9 ∗ 𝑉𝐸𝑆𝑇𝐴𝑇𝐼𝐶𝑂

2023.7 ≥ 0.9 ∗ 2248.2

2023.7 ≥ 2023.4 CUMPLE

20
6. CALCULO DE IRREGULARIDADES

 Irregularidad en planta

IRREGULARIDAD TORSIONAL
Tipo 1aP   1.4*(1+2)/2 1.2*(1+2)/2 Фp
Eje X 0.0038 0.0038 0.0053 0.0045
1
Eje Y 0.0053 0.0053 0.0074 0.0063

Tipo 1bP   1.4*(1+2)/2 Фp


Eje X 0.0038 0.0038 0.0053
1
Eje Y 0.0053 0.0053 0.0074

RETROCESOS EN LAS ESQUINAS


Tipo 2P
Eje X m A>0.15B Eje Y m C>0.15D Фp
A 1.8 C 3.59
0.9 1.34 0.9
B 6 D 8.91

 Irregularidad en altura

Tipo 1aA
Eje X Eje Y
Piso K 0.6*K piso 0.7*K piso 0.6*K piso 0.7*K piso Фa
(KN/m) sup. sup. K (KN/m) sup. sup.
5 28140 29604
4 75343 45206 52740 71094 42656 49765
3 85212 51127 59649 76129 45677 53290 1
2 90667 54400 63467 79951 47971 55966
1 99776 59865 69843 92623 55574 64836

Eje X Eje Y
Piso K 0.7*(K2+K 0.8*(K2+K 0.7*(K2+K 0.8*(K2+K3 Фa
(KN/m) 3+K4)/3 3+K4)/3 K (KN/m) 3+K4)/3 +K4)/3
5 28140 29604
4 75343 71094
3 85212 76129 1
2 90667 44029 50319 79951 41259 41259
1 99776 58618 66993 92623 53007 53007

21
Tipo 1bA
Eje X Eje Y
Piso 0.6*K piso 0.7*(K2+K 0.6*K piso 0.7*(K2+K3 Фa
K (KN/m) sup. 3+K4)/3 K (KN/m) sup. +K4)/3
5 28140 29604
4 75343 45206 71094 42656
3 85212 51127 76129 45677 1
2 90667 54400 44029 79951 47971 41259
1 99776 59865 58618 92623 55574 53007

Tipo 2A
Piso Masa (KN) 1.5*piso superior 1.5*piso inferior Фa
5 18
4 60 26 90
3 62 90 93 0.9
2 62 93 93
1 63 93

Tipo 3A
Eje Y m a>1.30b Фa
a 9.47
8.87 0.9
b 6.82

 Irregularidad por redundancia

Ausencia de Redundancia
Ejes Nº Columnas Фr
A 3 0.86
A' 1 0.71
B 2 0.71
C 2 0.71
1 2 0.71
2 3 0.86
3 3 0.86

22
 Resumen de irregularidades y cálculo de Ro

R0 7
Фa 0.9
Фp 0.9
Фr 0.75
R 4.25

ESPECTRO ELÁSTICO E INELÁSTICO DE DISEÑO


1.3
1.2
1.1
1.0
0.9 _______________ Espectro Elástico de Diseño
0.8
0.7
_______________ Espectro Inelástico de Diseño
Sa (%g)

0.6
0.5
0.4
0.3
0.2
0.1
0.0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
PERIODO T (Sg)

23
7. DISEÑO DE COLUMNAS

TABLE: Column Forces


Story Column Unique Name Load Case/Combo P(Ton)
Story1 C2 8 B245SYPP Min -73.5236
Story1 C1 4 B245SYPP Min -65.3624

 Chequeo de la sección columna C2

𝑃𝑢
𝐴𝑔 =
0.52[0.85(𝑓´𝑐 )(1 − 𝑝) + (𝑓𝑦 ∗ 𝑝)]

73523.6
𝐴𝑔 = = 509.3 𝑐𝑚2
0.52[0.85(280)(1 − 0.01) + (4200 ∗ 0.01)]

Dimensiones de la columna

√509.3 = 22.6 𝑐𝑚

Sección adoptada por derivas

𝑏𝑥ℎ = 45𝑐𝑚 ∗ 45𝑐𝑚 = 2025 𝑐𝑚2

Área de acero mínimo

𝐴𝑠 = 𝑝(𝐴𝑔 ) = 0.01 ∗ 2025 = 20.25 𝑐𝑚2

Acero adoptado

8#6 = 22.8 𝑐𝑚2

24
 Chequeo de la sección columna C1

𝑃𝑢
𝐴𝑔 =
0.52[0.85(𝑓´𝑐 )(1 − 𝑝) + (𝑓𝑦 ∗ 𝑝)]

65362.4
𝐴𝑔 = = 441.5 𝑐𝑚2
0.52[0.85(280)(1 − 0.01) + (4200 ∗ 0.01)]

Dimensiones de la columna

√509.3 = 21 𝑐𝑚

Sección adoptada por derivas

𝑏𝑥ℎ = 45𝑐𝑚 ∗ 45𝑐𝑚 = 2025 𝑐𝑚2

Área de acero mínimo

𝐴𝑠 = 𝑝(𝐴𝑔 ) = 0.01 ∗ 2025 = 20.25 𝑐𝑚2

Acero adoptado

8#6 = 22.8 𝑐𝑚2

25
Secciones adoptadas Chequeo diagrama de interaccion.

Columna C2 y C1 no cumplen en el piso 1 con el acero mínimo, las columnas no

están cumpliendo, algunos puntos del diagrama de interacción están por fuera.

26
Columna C2 Columna C1

Resumen de columna C2 y C1 piso 1.

TABLE: Concrete Column Summary - NSR 10


PMM PMM
Story Label Design Section Station Ratio Combo As,min As
m m² m²
Story1 C2 Columna2 45x45 0 1.211 B247SYNN 0.002025 0.002271
Story1 C2 Columna2 45x45 1.5 0.498 B247SYNN 0.002025 0.002271
Story1 C2 Columna2 45x45 3 0.624 B247SYNN 0.002025 0.002271
Story1 C1 Columna 1 45x45 0 1.10 B247SYNN 0.002025 0.003406
Story1 C1 Columna 1 45x45 1.5 0.248 B245SYNP 0.002025 0.003406
Story1 C1 Columna 1 45x45 3 0.357 B245SXNP 0.002025 0.003406

 Acero de refuerzo propuesto para las columnas C2 y C1 del piso 1

12#6 = 22.8 𝑐𝑚2

27
Chequeo diagrama de interaccion Chequeo relacion (6/5) viga/columna

Diagrama de interacción columna C2 y C1 piso 1, están cumpliendo, todas las

combinaciones de cargas están dentro del diagrama de interacción.

28
Columna C2 Columna C1

Con el diseño definitivo se obtiene el siguiente cuadro de resumen, todas las

columnas están cumpliendo.

TABLE: Concrete Column Summary - NSR 10


PMM
Story Label Design Section Station Ratio PMM Combo As,min As
m m² m²
Story5 C2 Columna3 30x30 0 0.474 B245SXNP 0.0009 0.001032
Story5 C2 Columna3 30x30 1.05 0.067 B245SXNP 0.0009 0.001032
Story5 C2 Columna3 30x30 2.1 0.341 B245SXNP 0.0009 0.001032
Story5 C5 Columna3 30x30 0 0.545 B245SYNP 0.0009 0.001032
Story5 C5 Columna3 30x30 1.05 0.066 B245SXNP 0.0009 0.001032
Story5 C5 Columna3 30x30 2.1 0.412 B245SYNP 0.0009 0.001032
Story4 C2 Columna2 45x45 0 0.382 B245SXNP 0.002025 0.002271
Story4 C2 Columna2 45x45 1.25 0.048 B245SYNP 0.002025 0.002271
Story4 C2 Columna2 45x45 2.5 0.454 B245SXNP 0.002025 0.002271
Story4 C1 Columna2 45x45 0 0.388 B245SYNP 0.002025 0.002271
Story4 C1 Columna2 45x45 1.25 0.056 B245SYNP 0.002025 0.002271
Story4 C1 Columna2 45x45 2.5 0.351 B245SYNP 0.002025 0.002271
Story3 C2 Columna2 45x45 0 0.517 B245SXNP 0.002025 0.002271
Story3 C2 Columna2 45x45 1.25 0.1 B245SYNP 0.002025 0.002271
Story3 C2 Columna2 45x45 2.5 0.45 B247SXNN 0.002025 0.002271
Story3 C1 Columna2 45x45 0 0.552 B247SXNN 0.002025 0.002271

29
TABLE: Concrete Column Summary - NSR 10
PMM
Story Label Design Section Station Ratio PMM Combo As,min As
m m² m²
Story3 C1 Columna2 45x45 1.25 0.103 B245SYNP 0.002025 0.002271
Story3 C1 Columna2 45x45 2.5 0.396 B245SYNP 0.002025 0.002271
Story2 C2 Columna2 45x45 0 0.752 B247SYNN 0.002025 0.002271
Story2 C2 Columna2 45x45 1.25 0.181 B247SYNN 0.002025 0.002271
Story2 C2 Columna2 45x45 2.5 0.552 B247SYNN 0.002025 0.002271
Story2 C1 Columna2 45x45 0 0.792 B247SXNN 0.002025 0.002271
Story2 C1 Columna2 45x45 1.25 0.16 B245SYNP 0.002025 0.002271
Story2 C1 Columna2 45x45 2.5 0.501 B247SXNN 0.002025 0.002271
Story1 C2 Columna 1 45x45 0 0.872 B247SYNN 0.002025 0.003406
Story1 C2 Columna 1 45x45 1.5 0.352 B247SYNN 0.002025 0.003406
Story1 C2 Columna 1 45x45 3 0.439 B247SYNN 0.002025 0.003406
Story1 C1 Columna 1 45x45 0 0.74 B247SYNN 0.002025 0.003406
Story1 C1 Columna 1 45x45 1.5 0.248 B245SYNP 0.002025 0.003406
Story1 C1 Columna 1 45x45 3 0.357 B245SXNP 0.002025 0.003406

7.1. Diseño a Cortante de columnas C1 y C2

 Refuerzo transversal

Longitud de confinamiento (Lo) C.21.6.4.1

𝐿𝑜1 = 45 𝑐𝑚

1
𝐿𝑜2 = ∗ 300 𝑐𝑚 = 50 𝑐𝑚
6

𝐿𝑜3 = 45 𝑐𝑚

𝐿𝑜 𝑎𝑠𝑢𝑚𝑖𝑑𝑜 = 50 𝑐𝑚

 Separación geométrica C.21.6.4.3, la menor de:

1
𝑆1 = ∗ 45 𝑐𝑚 = 11.25 𝑐𝑚
4
30
𝑆2 = 6 ∗ 1.59 𝑐𝑚 = 9.54 𝑐𝑚

35 − 17.5
𝑆3 = 10 + ( ) = 15.8 𝑐𝑚 → 𝑆3 = 15 𝑐𝑚
3

 Separación volumétrica para estribos cerrados de confinamiento

C.21.6.4.4(b)

2.13 ∗ 420
𝑆1 = = 5.25 𝑐𝑚
2025
0.3 ∗ 36 ∗ 28 ∗ ( − 1)
1296

2.13 ∗ 420
𝑆2 = = 9.86 𝑐𝑚
0.09 ∗ 36 ∗ 28

 Separación de los estribos en la longitud no confinada C.21.6.4.5

𝑆1 = 6 ∗ 1.59 𝑐𝑚 = 9.54 𝑐𝑚

𝑆2 = 15 𝑐𝑚

 Separación en la longitud de traslapo

𝑆1 = 9 𝑐𝑚

 Dimensión de columna donde el acero longitudinal de la viga atreviese un

nudo viga- columna C.21.7.2.3

𝑏 = 20 ∗ 𝑑𝑏 = 20 ∗ 2.22 = 44.4 𝑐𝑚 → 𝑂𝐾

 Refuerzo transversal en el nudo C.21.7.3

2.13 ∗ 420
𝑆1 = = 5.25 𝑐𝑚
2025
0.3 ∗ 36 ∗ 28 ∗ (1296 − 1)

31
2.13 ∗ 420
𝑆2 = = 9.86 𝑐𝑚
0.09 ∗ 36 ∗ 28

1
𝑆1 = ∗ 45 𝑐𝑚 = 11.25 𝑐𝑚
4

𝑆2 = 6 ∗ 1.59 𝑐𝑚 = 9.54 𝑐𝑚

35 − 17.5
𝑆3 = 10 + ( ) = 15.8 𝑐𝑚 → 𝑆3 = 15 𝑐𝑚
3

32
 Chequeo por cortante de columnas

TABLE: Column Design Forces


Pu Vux Vuy Mrx Col Mny Viga Vex Mry Col Mnx Viga Vey
Story Column Load Combo Station
kN kN kN kN-m kN-m kN kN-m kN-m kN
Story1 C1 B245SXNP top 597.54 76.92 70.55 357 202 199.0 357 126.3 161.1
Story1 C1 B245SXNP bottom 9.45 76.92 70.55 395 395 199.0 357 357 161.1
Story2 C1 B247SXNN top 22.85 71.75 62.75 230 186 129.3 230 112 79.4
Story2 C1 B247SXNN bottom 33.67 71.75 62.75 228 202 129.3 228 126.3 79.4
Story3 C1 B247SXNN top 34.91 55.36 51.06 222 144.1 110.0 222 86.2 66.1
Story3 C1 B247SXNN bottom 45.72 55.36 51.06 230 186 110.0 230 112 66.1
Story4 C1 B245SXNP top 57.71 52.50 50.00 225 106 83.4 225 41.4 42.5
Story4 C1 B245SXNP bottom 67.13 52.50 50.00 235 144.1 83.4 235 86.2 42.5
Story5 C5 B245SXNP top 8.96 18.60 23.30 61 18.25 27.4 61 22 31.0
Story5 C5 B245SXNP bottom 14.82 18.60 23.30 71 64 27.4 71 71 31.0

TABLE: Column Design Forces


Pu Vux Vuy Mrx Col Mny Viga Vex Mry Col Mnx Viga Vey
Story Column Load Combo Station
kN kN kN kN-m kN-m kN kN-m kN-m kN
Story1 C2 B247SYNN top 194.68 82.51 66.50 319 196 170.3 319 133 149.3
Story1 C2 B247SYNN bottom 181.79 82.51 66.50 315 315 170.3 315 315 149.3
Story2 C2 B247SYNN top 78.57 83.45 63.28 255 185 127.0 255 114 82.3
Story2 C2 B247SYNN bottom 67.84 83.45 63.28 245 196 127.0 245 133 82.3
Story3 C2 B247SYNN top 71.05 65.53 48.57 238 148 111.0 238 79 64.3
Story3 C2 B245SYNP bottom 138.50 65.53 48.57 242 185 111.0 242 114 64.3
Story4 C2 B245SXNP top 76.73 55.92 29.10 232 105 96.7 232 44 41.0
Story4 C2 B245SXNP bottom 91.00 55.92 29.10 238 185 96.7 238 79 41.0

33
TABLE: Column Design Forces
Pu Vux Vuy Mrx Col Mny Viga Vex Mry Col Mnx Viga Vey
Story Column Load Combo Station
kN kN kN kN-m kN-m kN kN-m kN-m kN
Story5 C2 B245SXNP top 13.60 22.06 20.80 63 20 28.3 63 14 19.3
Story5 C2 B245SXNP bottom 18.98 22.06 20.80 65 105 28.3 65 44 19.3

fi*Vc
Story Column fi*Vc Ve Vu >0.5*Ve Pu <Ag*f'c/20 adoptado fi*Vs S
Kgf KN KN KN KN KN KN KN cm
Story1 C1 144.43 199.0 76.92 99.5 597.54 283.5 144.43 54.57 50.03
Story2 C1 119.86 129.3 71.75 64.67 33.67 283.5 0 129.33 21.11
Story3 C1 120.37 110.0 55.36 55.02 45.72 283.5 0 110.03 24.81
Story4 C1 121.35 83.4 52.50 41.68 67.13 283.5 0 83.37 32.75
Story5 C5 119.26 31.0 23.30 15.5 14.82 126 0 31.00 55.45

fi*Vc
Story Column fi*Vc Ve Vu >0.5*Ve Pu <Ag*f'c/20 adoptado fi*Vs S
Kgf KN KN KN KN KN KN KN cm
Story1 C2 127.20 170.3 82.51 85.17 194.68 283.5 127.20 43.13 63.30
Story2 C2 122.24 127.0 83.45 63.50 78.57 283.5 0 127.00 21.50
Story3 C2 124.80 111.0 65.53 55.50 138.50 283.5 0 111.00 24.60
Story4 C2 122.77 96.7 55.92 48.33 91.00 283.5 0 96.67 28.24
Story5 C2 119.69 28.3 22.06 14.17 18.98 126 0 28.33 60.67

34
 Resumen de resultados

Zona de confinamiento

𝐿𝑜 = 50 𝑐𝑚

Separación de estribos zona confinada

𝑆𝑐 = 5 𝑐𝑚

Separación de estribos zona no confinada

𝑆𝑐 = 9 𝑐𝑚

7.2. Chequeo cortante en los nudos.

Ve (As1+As2) Vu Vn
Story Column
KN cm2 KN KN
Story1 C1 199.0 27.71 892.08 964.38
Story2 C1 129.3 24.86 849.53 964.38
Story3 C1 110.0 17.82 591.63 964.38
Story4 C1 83.4 13.86 462.37 964.38
Story5 C5 31.0 5.06 168.24 428.61

Ve (As1+As2) Vu fi*Vn
Story Column
KN cm2 KN KN
Story1 C3 170.3 27.71 920.75 964.38
Story2 C3 127.0 24.86 851.86 964.38
Story3 C3 111.0 17.58 581.21 964.38
Story4 C3 96.7 13.86 449.07 964.38
Story5 C3 28.3 5.06 170.90 428.61

35
8. DISEÑO DE VIGAS

 Chequeo de la sección por cortante y torsión.

TABLE: Beam Design Forces


Station V2 T M3 Cortante y Torsion Chequeo
Story Beam de seccion
m kN kN-m kN-m Mpa
(Mpa)
Story1 B8 0.225 -111.51 14.38 139.45 1.34
Story1 B8 0.225 40.09 14.38 -196.01 1.13
Story1 B8 4.32 92.53 3.77 -107.62 0.69
Story1 B8 4.32 -45.39 3.77 113.26 0.42
Story1 B8 5.32 101.54 3.77 -204.11 0.75 3.29
Story1 B8 5.32 -39.19 3.77 153.90 0.39 OK
Story1 B8 5.32 4.27 25.04 -12.46 1.80
Story1 B8 5.32 -24.33 25.04 0.72 1.92
Story1 B8 6.12 8.18 25.04 -4.30 1.92
Story1 B8 6.12 -18.83 25.04 4.77 1.92

TABLE: Beam Design Forces


Station V2 T M3 Cortante y Torsion Chequeo
Story Beam de seccion
m kN kN-m kN-m Mpa (Mpa)
Story2 B8 0.225 -106.58 14.27 124.53 1.31
Story2 B8 0.225 33.81 14.27 -185.57 1.12
Story2 B8 4.32 86.73 2.49 -98.11 0.62
Story2 B8 4.32 -40.60 2.49 104.17 0.34
Story2 B8 5.32 95.74 2.49 -188.72 0.68 3.29
Story2 B8 5.32 -34.40 2.49 139.96 0.30 OK
Story2 B8 5.32 1.64 22.00 -12.28 1.68
Story2 B8 5.32 -23.35 22.00 -0.44 1.69
Story2 B8 6.12 5.56 22.00 -3.35 1.68
Story2 B8 6.12 -17.85 22.00 4.17 1.69

TABLE: Beam Design Forces


Station V2 T M3 Cortante y Torsion Chequeo
Story Beam de seccion
m kN kN-m kN-m Mpa (Mpa)
Story3 B8 0.225 -90.46 13.36 83.67 1.19
Story3 B8 0.225 17.16 13.36 -148.29 1.03 3.29
Story3 B8 4.32 71.24 0.15 -73.06 0.48 OK
Story3 B8 4.32 -25.34 0.15 77.17 0.17

36
Story3 B8 5.32 80.25 0.15 -148.51 0.55
Story3 B8 5.32 -1.90 16.41 -10.96 1.25
Story3 B8 5.32 -19.14 0.15 98.02 0.13
Story3 B8 5.32 -20.46 16.41 -2.08 1.26
Story3 B8 6.12 2.02 16.41 -2.17 1.25
Story3 B8 6.12 -14.96 16.41 3.18 1.26

TABLE: Beam Design Forces


Station V2 T M3 Cortante y Torsion Chequeo
Story Beam de seccion
m kN kN-m kN-m Mpa (Mpa)
Story4 B8 0.225 -83.56 7.78 31.83 0.82
Story4 B8 0.225 -8.98 7.78 -105.88 0.60
Story4 B8 4.32 78.76 2.51 -29.99 0.57
Story4 B8 4.32 -7.42 2.51 44.07 0.20
Story4 B8 5.32 87.77 2.51 -110.90 0.63 3.29
Story4 B8 5.32 -6.00 8.98 -9.10 0.69 OK
Story4 B8 5.32 -1.22 2.51 44.95 0.19
Story4 B8 5.32 -16.26 8.98 -4.24 0.70
Story4 B8 6.12 -2.09 8.98 -1.03 0.69
Story4 B8 6.12 -10.75 8.98 1.67 0.69

TABLE: Beam Design Forces


Station V2 T M3 Cortante y Torsion Chequeo
Story Beam de seccion
m kN kN-m kN-m Mpa (Mpa)
Story5 B13 0.15 -12.67 2.22 18.26 0.75
Story5 B13 0.5933 -11.25 2.22 14.19 0.75
Story5 B13 1.0367 -9.70 2.22 9.34 0.74
Story5 B13 1.48 14.71 2.22 0.26 0.76
Story5 B13 1.9233 17.40 2.22 -3.72 0.78
Story5 B13 2.3667 19.47 2.22 -11.91 0.79
Story5 B13 2.81 20.92 2.22 -20.88 0.80 3.29
Story5 B13 0.15 8.83 2.22 -13.49 0.74 OK
Story5 B13 0.5933 9.96 2.22 -8.24 0.74
Story5 B13 1.0367 12.03 2.22 -3.58 0.75
Story5 B13 1.48 -7.69 2.22 3.61 0.74
Story5 B13 1.9233 -5.67 2.22 3.25 0.73
Story5 B13 2.3667 -4.12 2.22 5.40 0.73
Story5 B13 2.81 -3.03 2.22 6.97 0.73

La sección tiene sección suficiente para resistir los esfuerzos por cortante y torsión.

37
 Umbral de torsión

Umbral de Torsion viga B8 viga B13


Aoh [m2] 0.1 0.0374
Ph [m] 1.3 0.78
Acp [cm2] 1750 750
Pcp [cm2] 170 110
Tu [N.m] 5934.0 1684.4
Tu diseño [N.m] 23592.9 6697.1

Se debe considerar la torsión para todas las vigas del pórtico de análisis.

 Chequeo de área de acero

Cuantía balanceada(Pb) 0.018


Cuantía máxima (Pmax) 0.012
Acero máximo (cm2) 16.93
Acero mínimo (cm2) 4.9

38
 Acero por flexión suministrado

TABLE: Concrete Beam Summary - ACI 318-11


Station As,min Top As Top M3 Top Mmin Top As As norma As
Story Label Design Section
cm cm² cm² KN-m KN-m cm² cm² suministrado
Story5 B13 Viga7 25x30 15 1.83 1.83 18.26 18.26 1.16 1.83
Story5 B13 Viga7 25x30 59.33 1.36 1.36 14.19 14.19 0.90 1.83
Story5 B13 Viga7 25x30 103.67 0.86 0.86 9.34 10.44 0.66 0.88
2#4
Story5 B13 Viga7 25x30 148 0.86 0.86 0.26 10.44 0.66 0.88
2.53 cm2
Story5 B13 Viga7 25x30 192.33 0.86 0.86 -3.72 10.44 0.66 0.88
Story5 B13 Viga7 25x30 236.67 1.83 1.83 -11.91 11.91 0.75 1.83
Story5 B13 Viga7 25x30 281 1.83 2.66 -20.88 20.88 1.33 1.83
Story4 B8 Viga2 35x50 22.5 4.9 7.07 31.83 55.45 3.57 6.96
Story4 B8 Viga2 35x50 72.33 4.9 4.9 35.56 55.45 3.57 4.90
Story4 B8 Viga2 35x50 122.17 2.56 2.56 39.39 39.39 2.52 3.35 4#5
Story4 B8 Viga2 35x50 172 2.28 2.28 46.51 46.51 2.98 3.97 7.92 cm2
Story4 B8 Viga2 35x50 172 2.28 2.28 46.51 46.51 2.98 3.97
Story4 B8 Viga2 35x50 213.3 2.28 2.28 44.70 44.70 2.87 3.81
Story4 B8 Viga2 35x50 254.7 2.28 2.28 51.15 51.15 3.29 4.37
3#5
Story4 B8 Viga2 35x50 296 2.28 2.28 19.76 27.73 1.77 2.35
5.94 cm2
Story4 B8 Viga2 35x50 296 2.28 2.28 19.48 27.73 1.77 2.35
Story4 B8 Viga2 35x50 332 2.28 2.28 26.33 27.73 1.77 2.35
Story4 B8 Viga2 35x50 332 2.28 2.28 26.33 27.73 1.77 2.35
Story4 B8 Viga2 35x50 382 2.28 2.28 1.40 27.73 1.77 2.35 4#5
Story4 B8 Viga2 35x50 432 2.59 2.59 -29.99 29.99 1.91 2.54 7.92 cm2
Story4 B8 Viga2 35x50 482 4.9 4.9 -67.87 67.87 4.39 5.84
Story4 B8 Viga2 35x50 532 4.9 7.42 -110.90 110.90 7.31 7.31

39
TABLE: Concrete Beam Summary - ACI 318-11
Station As,min Top As Top M3 Top Mmin Top As As norma As
Story Label Design Section
cm cm² cm² KN-m KN-m cm² cm² suministrado
Story4 B8 Viga2 35x50 532 2.28 2.28 -9.10 55.45 3.57 4.75
Story4 B8 Viga2 35x50 572 2.28 2.28 -3.37 55.45 3.57 4.75 3#5
Story4 B8 Viga2 35x50 612 0.09 0.09 -1.03 1.03 0.06 0.09 5.94 cm2
Story3 B8 Viga2 35x50 22.5 4.9 10.08 83.67 83.67 5.45 9.93
Story3 B8 Viga2 35x50 72.33 4.9 6.96 74.37 74.37 4.82 6.85
Story3 B8 Viga2 35x50 122.17 4.9 4.9 63.19 63.19 4.08 5.43 2#6 y 3#5
Story3 B8 Viga2 35x50 172 3.21 3.21 55.92 55.92 3.60 4.79 11.64 cm2
Story3 B8 Viga2 35x50 172 3.21 3.21 55.92 55.92 3.60 4.79
Story3 B8 Viga2 35x50 212 3.21 3.21 42.67 42.67 2.73 3.63
Story3 B8 Viga2 35x50 252 3.21 3.21 28.20 37.13 2.37 3.16 2#6
Story3 B8 Viga2 35x50 292 3.21 3.21 2.64 37.13 2.37 3.16 5.7 cm2
Story3 B8 Viga2 35x50 332 3.21 3.21 -15.34 37.13 2.37 3.16
Story3 B8 Viga2 35x50 332 3.21 3.21 -15.34 37.13 2.37 3.16
Story3 B8 Viga2 35x50 382 3.76 3.76 -43.36 43.36 2.78 3.69
5#5
Story3 B8 Viga2 35x50 432 4.9 4.9 -73.06 73.06 4.74 6.30
9.90 cm2
Story3 B8 Viga2 35x50 482 4.9 7.3 -109.17 109.17 7.19 7.19
Story3 B8 Viga2 35x50 532 4.9 10.1 -148.51 148.51 9.95 9.95
Story3 B8 Viga2 35x50 532 3.21 3.21 -10.96 74.25 4.82 6.41
Story3 B8 Viga2 35x50 572 3.21 3.21 -3.62 74.25 4.82 6.41 2#6
Story3 B8 Viga2 35x50 612 0.19 0.19 -2.17 2.17 0.14 0.18 5.7 cm2
Story2 B8 Viga2 35x50 22.5 4.9 12.84 124.53 124.53 8.25 12.65
Story2 B8 Viga2 35x50 72.33 4.9 9.02 106.94 106.94 7.03 8.89
2#6 y 2#7
Story2 B8 Viga2 35x50 122.2 4.9 5.62 87.99 87.99 5.74 5.74
13.46 cm2
Story2 B8 Viga2 35x50 172 4.03 4.03 72.37 72.37 4.69 6.24
Story2 B8 Viga2 35x50 172 4.03 4.03 72.37 72.37 4.69 6.24

40
TABLE: Concrete Beam Summary - ACI 318-11
Station As,min Top As Top M3 Top Mmin Top As As norma As
Story Label Design Section
cm cm² cm² KN-m KN-m cm² cm² suministrado
Story2 B8 Viga2 35x50 212 4.03 4.03 52.71 52.71 3.39 4.51
Story2 B8 Viga2 35x50 252 4.03 4.03 31.92 47.18 3.03 4.03 2#6
Story2 B8 Viga2 35x50 292 4.03 4.03 -0.58 47.18 3.03 4.03 5.7 cm2
Story2 B8 Viga2 35x50 332 4.03 4.03 -24.95 47.18 3.03 4.03
Story2 B8 Viga2 35x50 332 4.03 4.03 -24.95 47.18 3.03 4.03
Story2 B8 Viga2 35x50 382 4.9 4.9 -60.68 60.68 3.91 5.21
2#6 y 2#7
Story2 B8 Viga2 35x50 432 4.9 6.53 -98.11 98.11 6.43 6.43
13.46 cm2
Story2 B8 Viga2 35x50 482 4.9 9.6 -141.65 141.65 9.46 9.46
Story2 B8 Viga2 35x50 532 4.9 13.08 -188.72 188.72 12.88 12.88
Story2 B8 Viga2 35x50 532 4.03 4.03 -12.28 94.36 6.17 6.17
Story2 B8 Viga2 35x50 572 4.03 4.03 -3.82 94.36 6.17 6.17 2#6
Story2 B8 Viga2 35x50 612 0.29 0.29 -3.35 3.35 0.21 0.28 5.7 cm2
Story1 B8 Viga2 35x50 22.5 4.9 13.63 139.45 139.45 9.30 13.43
Story1 B8 Viga2 35x50 72.33 4.9 9.6 118.73 118.73 7.85 9.45
Story1 B8 Viga2 35x50 122.17 4.9 6.05 97.34 97.34 6.38 6.38 3#6 y 2#7
Story1 B8 Viga2 35x50 172 4.26 4.26 78.46 78.46 5.10 5.10 16.31 cm2
Story1 B8 Viga2 35x50 172 4.26 4.26 78.46 78.46 5.10 5.10
Story1 B8 Viga2 35x50 212 4.26 4.26 56.34 56.34 3.63 4.82
Story1 B8 Viga2 35x50 252 4.26 4.26 33.33 49.00 3.15 4.18 2#6
Story1 B8 Viga2 35x50 292 4.26 4.26 -2.14 49.00 3.15 4.18 5.7 cm2
Story1 B8 Viga2 35x50 332 4.26 4.26 -28.88 49.00 3.15 4.18
Story1 B8 Viga2 35x50 332 4.26 4.26 -28.88 49.00 3.15 4.18
3#6 y 2#7
Story1 B8 Viga2 35x50 382 4.9 4.9 -67.40 67.40 4.36 5.80
16.31 cm2
Story1 B8 Viga2 35x50 432 4.9 7.19 -107.62 107.62 7.08 7.08
Story1 B8 Viga2 35x50 482 4.9 10.51 -154.13 154.13 10.35 10.35

41
TABLE: Concrete Beam Summary - ACI 318-11
Station As,min Top As Top M3 Top Mmin Top As As norma As
Story Label Design Section
cm cm² cm² KN-m KN-m cm² cm² suministrado
Story1 B8 Viga2 35x50 532 4.9 14.25 -204.11 204.11 14.04 14.04
Story1 B8 Viga2 35x50 532 4.26 4.26 -12.46 98.01 6.42 6.42
Story1 B8 Viga2 35x50 572 4.26 4.26 -3.62 98.01 6.42 6.42 2#6
Story1 B8 Viga2 35x50 612 0.37 0.37 -4.30 4.30 0.27 0.36 5.7 cm2

TABLE: Concrete Beam Summary - ACI 318-11


Station As,min Top As Top M3 Top Mmin Top As As norma As
Story Label Design Section
cm cm² cm² KN-m KN-m cm² cm² suministrado
Story5 B13 Viga7 25x30 15 1.83 2.31 -13.49 13.49 0.85 1.83
Story5 B13 Viga7 25x30 59.33 1.83 1.83 -8.24 10.44 0.66 1.83
Story5 B13 Viga7 25x30 103.67 1.55 1.55 -3.58 10.44 0.66 0.88
2#4
Story5 B13 Viga7 25x30 148 0.86 0.86 3.61 10.44 0.66 0.88
2.53 cm2
Story5 B13 Viga7 25x30 192.33 0.86 0.86 3.25 10.44 0.66 0.88
Story5 B13 Viga7 25x30 236.67 0.89 0.89 5.40 10.44 0.66 1.83
Story5 B13 Viga7 25x30 281 1.74 1.74 6.97 10.44 0.66 1.83
Story4 B8 Viga2 35x50 22.5 4.61 4.61 -105.88 105.88 6.96 4.90
Story4 B8 Viga2 35x50 72.33 3.07 3.07 -65.34 65.34 4.22 4.90
Story4 B8 Viga2 35x50 122.17 3.41 3.41 -29.65 29.65 1.89 2.51 3#5
Story4 B8 Viga2 35x50 172 4.04 4.04 -1.36 27.73 1.77 2.35 5.94 cm2
Story4 B8 Viga2 35x50 172 4.04 4.04 -1.36 27.73 1.77 2.35
Story4 B8 Viga2 35x50 213.33 3.88 3.88 16.23 27.73 1.77 2.35
Story4 B8 Viga2 35x50 254.67 4.45 4.45 26.79 27.73 1.77 2.35
3#5
Story4 B8 Viga2 35x50 296 4.9 4.9 64.27 64.27 4.15 5.52
5.94 cm2
Story4 B8 Viga2 35x50 296 4.9 4.9 65.88 65.88 4.26 5.66

42
TABLE: Concrete Beam Summary - ACI 318-11
Station As,min Top As Top M3 Top Mmin Top As As norma As
Story Label Design Section
cm cm² cm² KN-m KN-m cm² cm² suministrado
Story4 B8 Viga2 35x50 332 4.57 4.57 52.56 52.56 3.38 4.49
Story4 B8 Viga2 35x50 332 4.57 4.57 52.56 52.56 3.38 4.49
Story4 B8 Viga2 35x50 382 3.96 3.96 45.67 45.67 2.93 3.89
3#5
Story4 B8 Viga2 35x50 432 3.82 3.82 44.07 44.07 2.82 3.76
5.94 cm2
Story4 B8 Viga2 35x50 482 3.8 3.8 43.83 43.83 2.81 3.73
Story4 B8 Viga2 35x50 532 3.9 3.9 44.95 44.95 2.88 3.83
Story4 B8 Viga2 35x50 532 2.28 2.28 -4.24 55.45 3.57 4.75
Story4 B8 Viga2 35x50 572 2.28 2.28 -2.01 55.45 3.57 4.75 3#5
Story4 B8 Viga2 35x50 612 0.14 0.14 1.67 1.67 0.11 0.14 5.94 cm2
Story3 B8 Viga2 35x50 22.5 4.9 5.53 -148.29 148.29 9.93 5.45
Story3 B8 Viga2 35x50 72.33 4.9 4.9 -104.31 104.31 6.85 4.90
Story3 B8 Viga2 35x50 122.17 4.9 4.9 -63.19 63.19 4.08 5.43 3#5
Story3 B8 Viga2 35x50 172 4.87 4.87 -30.09 37.13 2.37 3.16 5.94 cm2
Story3 B8 Viga2 35x50 172 4.87 4.87 -30.09 37.13 2.37 3.16
Story3 B8 Viga2 35x50 212 3.7 3.7 -9.23 37.13 2.37 3.16
Story3 B8 Viga2 35x50 252 3.21 3.21 10.45 37.13 2.37 3.16 2#5
Story3 B8 Viga2 35x50 292 3.3 3.3 38.15 38.15 2.44 3.24 3.96 cm2
Story3 B8 Viga2 35x50 332 4.87 4.87 55.86 55.86 3.60 4.78
Story3 B8 Viga2 35x50 332 4.87 4.87 55.86 55.86 3.60 4.78
Story3 B8 Viga2 35x50 382 4.9 4.9 67.74 67.74 4.38 5.83
4#5
Story3 B8 Viga2 35x50 432 4.9 5.09 77.17 77.17 5.01 5.01
7.92 cm2
Story3 B8 Viga2 35x50 482 4.9 5.82 87.89 87.89 5.73 5.73
Story3 B8 Viga2 35x50 532 4.9 6.52 98.02 98.02 6.42 6.42
Story3 B8 Viga2 35x50 532 3.21 3.21 -2.08 74.25 4.82 6.41
Story3 B8 Viga2 35x50 572 3.21 3.21 -1.37 74.25 4.82 6.41

43
TABLE: Concrete Beam Summary - ACI 318-11
Station As,min Top As Top M3 Top Mmin Top As As norma As
Story Label Design Section
cm cm² cm² KN-m KN-m cm² cm² suministrado
2#5
3.18 3.18 0.20
Story3 B8 Viga2 35x50 612 0.27 0.27 0.27 3.96 cm2
Story2 B8 Viga2 35x50 22.5 4.9 8.38 -185.57 185.57 12.65 8.25
Story2 B8 Viga2 35x50 72.33 4.9 7.14 -133.55 133.55 8.89 7.03
Story2 B8 Viga2 35x50 122.17 4.9 5.83 -84.94 84.94 5.53 5.53 3#6
Story2 B8 Viga2 35x50 172 4.9 4.9 -43.76 47.18 3.03 4.03 8.55 cm2
Story2 B8 Viga2 35x50 172 4.9 4.9 -43.76 47.18 3.03 4.03
Story2 B8 Viga2 35x50 212 4.59 4.59 -16.63 47.18 3.03 4.03
Story2 B8 Viga2 35x50 252 4.03 4.03 9.22 47.18 3.03 4.03 2#6
Story2 B8 Viga2 35x50 292 4.03 4.03 43.70 47.18 3.03 4.03 5.7 cm2
Story2 B8 Viga2 35x50 332 4.9 4.9 67.65 67.65 4.38 5.82
Story2 B8 Viga2 35x50 332 4.9 4.9 67.65 67.65 4.38 5.82
Story2 B8 Viga2 35x50 382 4.9 5.77 87.13 87.13 5.68 5.68
4#6
Story2 B8 Viga2 35x50 432 4.9 6.95 104.17 104.17 6.84 6.84
11.40 cm2
Story2 B8 Viga2 35x50 482 4.9 8.21 122.19 122.19 8.09 8.09
Story2 B8 Viga2 35x50 532 4.9 9.48 139.96 139.96 9.34 9.34
Story2 B8 Viga2 35x50 532 4.03 4.03 -0.44 94.36 6.17 6.17
Story2 B8 Viga2 35x50 572 4.03 4.03 -1.11 94.36 6.17 6.17 2#6
Story2 B8 Viga2 35x50 612 0.36 0.36 4.17 4.17 0.26 0.35 5.7 cm2
Story1 B8 Viga2 35x50 22.5 4.9 9.45 -196.01 196.01 13.43 9.30
Story1 B8 Viga2 35x50 72.33 4.9 7.97 -141.54 141.54 9.45 7.85
Story1 B8 Viga2 35x50 122.17 4.9 6.47 -91.16 91.16 5.95 5.95 4#6
Story1 B8 Viga2 35x50 172 4.9 5.18 -47.39 49.00 3.15 4.18 11.40 cm2
Story1 B8 Viga2 35x50 172 4.9 5.18 -47.39 49.00 3.15 4.18
Story1 B8 Viga2 35x50 212 4.9 4.9 -18.28 49.00 3.15 4.18

44
TABLE: Concrete Beam Summary - ACI 318-11
Station As,min Top As Top M3 Top Mmin Top As As norma As
Story Label Design Section
cm cm² cm² KN-m KN-m cm² cm² suministrado
Story1 B8 Viga2 35x50 252 4.26 4.26 9.33 49.00 3.15 4.18 2#6
Story1 B8 Viga2 35x50 292 4.26 4.26 46.31 49.00 3.15 4.18 5.7 cm2
Story1 B8 Viga2 35x50 332 4.9 4.9 72.16 72.16 4.68 6.22
Story1 B8 Viga2 35x50 332 4.9 4.9 72.15 72.15 4.68 6.22
Story1 B8 Viga2 35x50 382 4.9 6.24 93.93 93.93 6.14 6.14
4#6
Story1 B8 Viga2 35x50 432 4.9 7.58 113.26 113.26 7.47 7.47
11.40 cm2
Story1 B8 Viga2 35x50 482 4.9 9.04 133.74 133.74 8.90 8.90
Story1 B8 Viga2 35x50 532 4.9 10.49 153.90 153.90 10.34 10.34
Story1 B8 Viga2 35x50 532 4.26 4.26 0.72 98.01 6.42 6.42
Story1 B8 Viga2 35x50 572 4.26 4.26 -1.00 98.01 6.42 6.42 2#6
Story1 B8 Viga2 35x50 612 0.41 0.41 4.77 4.77 0.30 0.40 5.7 cm2

45
 Acero mínimo para soportar la torsión.

Viga B8 Piso 1 Viga B8 Piso 2 Viga B8 Piso 3 Viga B8 Piso 4 Viga B13 Piso 5
Inicio
Tu 14.38 14.27 13.36 7.78 2.22
At/S 1 0.00026853 0.00026648 0.00024949 0.00014528 0.00011085
At/S 2 0.000145833 0.000145833 0.000145833 0.000145833 0.000104167
At/S 0.00026853 0.00026648 0.00024949 0.00014583 0.00011085
Al (cm2) 3.49 3.46 3.24 1.90 0.86
Almin (cm2) 5.77 5.80 6.02 7.36 3.10
Al sum. (cm2) 5.77 5.80 6.02 7.36 3.10
Medio
Tu 3.77 2.49 0.15 2.51 2.22
At/S 1 0.00007040 0.00004650 0.00000280 0.00004687 0.00011085
At/S 2 0.000145833 0.000145833 0.000145833 0.000145833 0.000104167
At/S 0.00014583 0.00014583 0.00014583 0.00014583 0.00011085
Al (cm2) 1.90 1.90 1.90 1.90 0.86
Almin (cm2) 7.36 7.36 7.36 7.36 3.10
Al sum.(cm2) 7.36 7.36 7.36 7.36 3.10
Fin
Tu 25.04 22 16.41 8.98 2.22
At/S 1 0.00046760 0.00041083 0.00030644 0.00016769 0.00011085
At/S 2 0.000145833 0.000145833 0.000145833 0.000145833 0.000104167
At/S 0.00046760 0.00041083 0.00030644 0.00016769 0.00011085
Al (cm2) 6.08 5.34 3.98 2.18 0.86
Almin (cm2) 3.18 3.92 5.28 7.08 3.10
Al sum.(cm2) 6.08 5.34 5.28 7.08 3.10

8.1. Diseño por cortante

Viga B8 Piso Viga B8 Piso Viga B8 Piso Viga B8 Piso Viga B13Piso
REQUISITOS 1 2 3 4 5
fiVc (KN) 99.18 99.18 99.18 99.18 37.11
Vud (KN) 111.51 106.58 90.46 87.77 20.9245
fiVs (KN) 12.33 7.41 -8.71 -11.41 -16.18
fiVs chequeo (KN) 385.04 385.04 385.04 385.04 144.06
Av #3 (cm2) 1.43 1.43 1.43 1.43 1.43
S1 (m) 1.27 2.12 -1.80 -1.38 -0.69
S2 (m) 0.52 0.52 0.52 0.52 0.73

46
Viga B8 Piso Viga B8 Piso Viga B8 Piso Viga B8 Piso Viga B13Piso
REQUISITOS 1 2 3 4 5
S2 (m) 0.49 0.49 0.49 0.49 0.68
Vs2max (KN) 256.69 256.69 256.69 256.69 96.04
S3 (m) 0.21 0.21 0.21 0.21 0.11
S3 (m) 0.6 0.6 0.6 0.6 0.6
S1 Torsion (m) 0.13 0.13 0.13 0.13 N/A
S2 Torsion (m) 0.30 0.30 0.30 0.30 N/A

Long. Estribos
X (m) 2.37 2.48 2.92 3.01 4.72
L1 (m) 2.95 2.84 2.40 2.31 -1.91

C.21 - NSR 10
Long.
Confinamiento (m) 1 1 1 1 1
C.21.5.3.2
S4 (m) 0.105 0.105 0.105 0.105 0.105
S5 (m) 11.46 11.46 9.54 9.54 7.62
S6 (m) 0.15 0.15 0.15 0.15 0.15

 Resumen de resultados

Zona de confinamiento

𝐿𝑜 = 100 𝑐𝑚

Separación de estribos zona confinada

𝑆𝑐 = 10 𝑐𝑚

Separación de estribos zona no confinada

𝑆𝑐 = 13 𝑐𝑚

47
9. DISEÑO LOSA DE ENTREPISO

𝐾𝑁
𝐶𝑎𝑟𝑔𝑎 𝑚𝑢𝑒𝑟𝑡𝑎 𝐷 = 6.75
𝑚2

𝐾𝑁
𝐶𝑎𝑟𝑔𝑎 𝑣𝑖𝑣𝑎 𝐿 = 1.8
𝑚2

𝐶𝑜𝑚𝑏𝑖𝑛𝑎𝑐𝑖𝑜𝑛 𝑑𝑒 𝑐𝑎𝑟𝑔𝑎: 1.2 ∗ 𝐷 + 1.6 ∗ 𝐿

𝐾𝑁
𝑤 = 1.2 ∗ 6.75 + 1.6 ∗ 1.8 = 10.98
𝑚2

Se toma una franja de un metro de ancho

𝐾𝑁
𝑞𝑢 = 10.98
𝑚

Diagrama de fuerzas

Diagrama de cortantes

48
Diagrama de momentos

𝑀𝑜𝑚𝑒𝑛𝑡𝑜 𝑚á𝑥𝑖𝑚𝑜 𝑎𝑝𝑜𝑦𝑜: 3.33 𝐾𝑁. 𝑚

𝑀𝑜𝑚𝑒𝑛𝑡𝑜 𝑚á𝑥𝑖𝑚𝑜 𝑙𝑢𝑧: 2.64 𝐾𝑁. 𝑚

 Diseño a flexión

𝑑 = 7 𝑐𝑚

𝜌𝑚𝑖𝑛 = 0.0018

𝐴𝑠𝑚𝑖𝑛 = 0.0018 ∗ 100 ∗ 8 = 1.44 𝑐𝑚2/𝑚

𝜌𝑏 = 0.014

𝜌𝑚𝑎𝑥 = 0.00864

𝐴𝑠𝑚𝑎𝑥 = 0.00864 ∗ 100 ∗ 8 = 6.91 𝑐𝑚2/𝑚

𝑀𝑢− = 3.33 𝐾𝑁. 𝑚

𝐴𝑠 − = 0.21 𝑐𝑚2/𝑚

𝐴𝑠 − = 𝑚𝑎𝑙𝑙𝑎 𝑒𝑙𝑒𝑐𝑡𝑟𝑜𝑠𝑜𝑙𝑑𝑎𝑑𝑎 𝑔𝑟𝑎𝑓𝑖𝑙 5𝑚𝑚 15𝑐𝑚𝑥15𝑐𝑚 = 1.58𝑐𝑚2/𝑚

𝑀𝑢+ = 2.64 𝐾𝑁. 𝑚

𝐴𝑠 + = 0.17 𝐾𝑁. 𝑚

𝐴𝑠 + = 𝑚𝑎𝑙𝑙𝑎 𝑒𝑙𝑒𝑐𝑡𝑟𝑜𝑠𝑜𝑙𝑑𝑎𝑑𝑎 𝑔𝑟𝑎𝑓𝑖𝑙 5𝑚𝑚 15𝑐𝑚𝑥15𝑐𝑚 = 1.58𝑐𝑚2/𝑚

 Diseño a cortante

𝑉𝑢 𝑚𝑎𝑥 = 11.6 𝐾𝑁 (𝑒𝑛 𝑒𝑙 𝑒𝑗𝑒)

√𝑓´𝑐 √21
𝑉𝑐 = ∗𝑏∗𝑑 = ∗ 1 ∗ 0.08 ∗ 103 = 61.1 𝐾𝑁
6 6
∅𝑉𝑐 = 0.75 ∗ 61.1 = 45.8 𝐾𝑁

49
𝑉𝑢 < ∅𝑉𝑐 → 𝑛𝑜 𝑟𝑒𝑞𝑢𝑖𝑒𝑟𝑒 𝑟𝑒𝑓𝑢𝑒𝑟𝑧𝑜

 As contracción y temperatura

𝐴𝑠𝑟 = 0.0018 ∗ 100 ∗ 10 ∗ 1.25 = 2.25 𝑐𝑚2/𝑚

𝐴𝑠𝑟 = 𝑚𝑎𝑙𝑙𝑎 𝑒𝑙𝑒𝑐𝑡𝑟𝑜𝑠𝑜𝑙𝑑𝑎𝑑𝑎 𝑔𝑟𝑎𝑓𝑖𝑙 6.5 𝑚𝑚 15𝑐𝑚𝑥15𝑐𝑚 = 2.56 𝑐𝑚2/𝑚

9.1. Diseño de vigas auxiliares

 Viga auxiliar 1, perfil metálico.

Perfiles posibles:

No Seccion p x 10^3 bx x 10^3 by x 10^3 D/C


1 W6X12 36.68 56.37 102.17 0.98
2 W8X13 40.22 55.73 110.25 0.97
3 W12X14 46.53 54.92 124.76 0.96
4 W4X13 28.66 49.62 81.18 0.86
5 W10X15 37.93 46.40 103.06 0.81
6 W12X16 39.00 43.60 105.07 0.76
7 W8X15 32.21 41.03 88.78 0.71
8 W10X17 30.80 35.25 84.66 0.61
9 W6X16 24.76 31.37 69.92 0.55
10 W5X16 14.68 31.30 51.75 0.55

Perfil más liviano: W6x12

50
 Diseño por cortante F.2.7

Datos de entrada
Fy [Mpa] 344.74
E [Mpa] 200000
Aw [mm2] 894.77

kv sin rigidizadores
5
(F-79)

Procedimiento
h/tw 21.60
F.2.7.2.2 53.95
F.2.7.2.3 59.2443374
F.2.7.2.4 73.7861293

Datos calculados
Øv 1
Cv 1
Vn [N] 185078.303
Øv*Vn [N] 185078.303

𝑉𝑢 = 25700 𝑁

𝑉𝑈 < ∅𝑉𝑛 → 𝑂𝐾

 Diseño por flexión F.2.4.

Entrada datos
E[Mpa] 200000
Fy[Mpa] 344.74
L[mm] 4000
Lb[mm] 4000
c(adim) (F2.6.2.8-a-,b) 1
Cb (F2.6.1.1) Pag 190 1

Seccion compacta???? SI
Grupo 3
Procedimiento
Patin F.2.2.4-1b 9.2 COMPACTO

51
Alma F.2.2.4-1b 90.6 COMPACTO
Lp [mm] (F.2.6.2.5) 988.5
Lr [mm] (F.2.6.2.6) 3419.9 SI
Mp [N.mm] (F.2.2.1) 46888994.5
Mn<Mp (F2.6.2-1) 23755443.0
Fcr [Mpa] (F2.6.2.4) 198.3
w nominal [N/mm] 10.7
Datos calculados
Øb Mnx[KN.m] 21.4
0.982
I (F.2.8.1-1b)
OK

𝑀𝑢 = 21 𝐾𝑁. 𝑚

𝑀𝑈 < ∅𝑏 𝑀𝑛 → 𝑂𝐾

Se puede utilizar un perfil IPE200, el cual es equivalente al W6X12

 Viga auxiliar 2, perfil metálico.

Perfiles posibles:

Seccion p x 10^3 bx x 10^3 by x 10^3 D/C


W6X8.5 132.947 73.949 157.406 0.810
W6X9 120.901 65.051 137.848 0.712
W8X10 126.758 57.853 145.252 0.633
W10X12 121.652 46.172 137.652 0.506
W4X13 69.289 45.283 81.177 0.496
W6X12 88.705 42.921 102.171 0.470
W8X13 97.247 39.340 110.249 0.431

52
Seccion p x 10^3 bx x 10^3 by x 10^3 D/C
W12X14 112.506 36.687 124.756 0.402
W10X15 91.717 32.079 103.059 0.351

Perfil más liviano: W6X9

 Diseño por flexion

Entrada datos
E[Mpa] 200000
Fy[Mpa] 344.74
L[mm] 6220
Lb[mm] 3110
c(adim) (F2.6.2.8-
a-,b) 1
Cb (F2.6.1.1) Pag 190 1

Sección compacta SI
Grupo 3
Procedimiento
Patín F.2.2.4-1b 9.2
Alma F.2.2.4-1b 90.6
Lp [mm] (F.2.6.2.5) 974.5
Lr [mm] (F.2.6.2.6) 2973.0
Mp [N.mm] (F.2.2.1) 35194992.2
Mn<Mp (F2.6.2-1) 20585285.3
Fcr [Mpa] (F2.6.2.4) 225.9
w nominal [N/mm] 3.8
Datos calculados
Øb Mnx [KN.m] 18.53
0.982
I (F.2.8.1-1b)
OK

𝑀𝑢 = 13 𝐾𝑁. 𝑚

𝑀𝑈 < ∅𝑏 𝑀𝑛 → 𝑂𝐾

Se puede utilizar un perfil IPE180, el cual es equivalente al W6X9

53
10. DISEÑO DE CIMENTACIÓN

 Características generales:

𝑃𝑟𝑜𝑓𝑢𝑛𝑑𝑖𝑑𝑎𝑑 𝑑𝑒 𝑑𝑒𝑠𝑝𝑙𝑎𝑛𝑡𝑒 ∶ 1.5 𝑚

𝐶𝑎𝑝𝑎𝑐𝑖𝑑𝑎𝑑 𝑝𝑜𝑟𝑡𝑎𝑛𝑡𝑒 𝑑𝑒𝑙 𝑠𝑢𝑒𝑙𝑜: 12.55 𝑇𝑜𝑛/𝑚2

𝐾 𝑏𝑎𝑙𝑎𝑠𝑡𝑜 𝑝𝑎𝑟𝑎 𝑐𝑖𝑚𝑒𝑛𝑡𝑎𝑐𝑖𝑜𝑛: 2.65 𝐾𝑔/𝑐𝑚3

𝐾 𝑏𝑎𝑙𝑎𝑠𝑡𝑜 𝑝𝑎𝑟𝑎 𝑣𝑖𝑔𝑎 𝑑𝑒 𝑐𝑖𝑚𝑒𝑛𝑡𝑎𝑐𝑖𝑜𝑛: 2.65 ∗ 40 = 106 𝐾𝑔/𝑐𝑚/𝑐𝑚

En el estudio de suelos se recomienda cimentación superficial tipo zapata. Se

realiza el siguiente pre-dimensionamiento:

𝐴𝑙𝑡𝑢𝑟𝑎 𝑣𝑖𝑔𝑎 𝑑𝑒 𝑝𝑖𝑠𝑜 = 60 𝑐𝑚

𝐴𝑛𝑐ℎ𝑜 𝑣𝑖𝑔𝑎 𝑑𝑒 𝑝𝑖𝑠𝑜 = 40 𝑐𝑚

𝐴𝑙𝑡𝑢𝑟𝑎 𝑧𝑎𝑝𝑎𝑡𝑎 = 60 𝑐𝑚

 Pre dimensionamiento zapata

54
αs (Posición columnas)
Col. Interiores 40
Col. Borde 30
Col. Esquina 20

σadm (Mpa) 0.123


t prom(m) 0.50
Recubrimiento (m) 0.075

Ps σneto Area Ancho Ancho


COL. αs
(KN) (Mpa) (m2) (m) sum.(m)
1 20 306.5 0.111 1.972 1.404 2.00
2 20 274.2 0.111 1.764 1.328 2.00
3 30 309.1 0.111 1.989 1.410 2.00
4 20 427.2 0.111 2.749 1.658 2.00
6 20 360.2 0.111 2.318 1.523 2.00
7 20 369.2 0.111 2.376 1.541 2.00
8 20 312.7 0.111 2.012 1.418 2.00
9 30 551.3 0.111 3.548 1.884 2.00

Las dimensiones de las columnas son bastante grandes considerando que se tratan

de zapatas esquineras y luces pequeñas, por lo cual estas llegan a traslaparse, con

esta consideración se comienza con un pre-dimensionamiento de una zapata

corrida de la siguiente manera:

Presiones muy bajas en la zona

central por lo cual se puede reducir la

losa de cimentaciones a un sistema

de zapatas continuas:

55
Ajustamos el modelo hasta obtener las presiones del suelo requeridas y las

dimensiones son:

𝐴𝑙𝑡𝑢𝑟𝑎 𝑧𝑎𝑝𝑎𝑡𝑎 𝑐𝑜𝑛𝑡𝑖𝑛𝑢𝑎: 50 𝑐𝑚

𝐴𝑛𝑐ℎ𝑜 𝑧𝑎𝑝𝑎𝑡𝑎 𝑐𝑜𝑛𝑡𝑖𝑛𝑢𝑎: 90 𝑐𝑚

𝐴𝑙𝑡𝑢𝑟𝑎 𝑣𝑖𝑔𝑎 𝑑𝑒 𝑐𝑖𝑚𝑒𝑛𝑡𝑎𝑐𝑖ó𝑛: 50 𝑐𝑚

𝐴𝑛𝑐ℎ𝑜 𝑣𝑖𝑔𝑎 𝑑𝑒 𝑐𝑖𝑚𝑒𝑛𝑡𝑎𝑐𝑖ó𝑛: 40 𝑐𝑚

 Acero de refuerzo propuesto:

De acuerdo al acero de refuerzo requerido para la zapata eje C se propuso la

siguiente distribución de acero de refuerzo:

𝑇𝑜𝑝: 𝐷𝑖𝑟𝑒𝑐𝑐𝑖𝑜𝑛 𝑥, 𝑦 → 𝑏𝑎𝑟𝑟𝑎𝑠 #6 𝑐𝑎𝑑𝑎 15 𝑐𝑚

𝐵𝑜𝑡𝑡𝑜𝑚: 𝐷𝑖𝑟𝑒𝑐𝑐𝑖𝑜𝑛 𝑥, 𝑦 → 𝑏𝑎𝑟𝑟𝑎𝑠 #6 𝑐𝑎𝑑𝑎 20 𝑐𝑚

56
 Diseño de zapata continua eje C

57
58
 Diagrama con el acero propuesto mm2/m

Dirección x Top Rebar

Dirección x Bottom Rebar

Dirección y Top Rebar

59
Dirección y Bottom Rebar

10.1. Viga de cimentación

Geometric Properties

Combination = Overall Envelope


Beam Label = L5
Section Property = viga de cimentacion
Length = 5.32 m
Section Width = 400 mm
Section Depth = 500 mm
Distance to Top Rebar Center = 75 mm
Distance to Bot Rebar Center = 75 mm

Material Properties

Concrete Comp. Strength = 28 N/mm2


Concrete Modulus = 24870.06 N/mm2
Longitudinal Rebar Yield = 400 N/mm2
Shear Rebar Yield = 400 N/mm2

60
61
𝑀𝑢− = 105.6 𝐾𝑁. 𝑚

𝐴𝑠 − = 9.56 𝑐𝑚2

𝐴𝑠 − = 4#6 = 11.4 𝑐𝑚2/𝑚

𝑀𝑢+ = 71.2 𝐾𝑁. 𝑚

𝐴𝑠 + = 4.6 𝑐𝑚2
+
𝐴𝑠𝑚𝑖𝑛 = 5.6 𝑐𝑚2

𝐴𝑠 + = 4#5 = 7.92 𝑐𝑚2

 Diseño a cortante

𝑉𝑢 𝑚𝑎𝑥 = 154 𝐾𝑁

√𝑓´𝑐 √21
𝑉𝑐 = ∗𝑏∗𝑑 = ∗ 0.5 ∗ 0.46 ∗ 103 = 161.8 𝐾𝑁
6 6
∅𝑉𝑐 = 0.75 ∗ 161.8 = 121.4 𝐾𝑁

∅𝑉𝑠 = 154 − 121.4 = 32.6 𝐾𝑁

𝑆 = 12 𝑐𝑚

𝐿𝑜𝑛𝑔𝑖𝑡𝑢𝑑 𝑑𝑒 𝑐𝑜𝑛𝑓𝑖𝑛𝑎𝑚𝑖𝑒𝑛𝑡𝑜: 1𝑚

𝑆 = 10 𝑐𝑚

62
 Resumen

 Zapata continua

𝑇𝑜𝑝: 𝐷𝑖𝑟𝑒𝑐𝑐𝑖𝑜𝑛 𝑥, 𝑦 → 𝑏𝑎𝑟𝑟𝑎𝑠 #6 𝑐𝑎𝑑𝑎 15 𝑐𝑚

𝐵𝑜𝑡𝑡𝑜𝑚: 𝐷𝑖𝑟𝑒𝑐𝑐𝑖𝑜𝑛 𝑐𝑜𝑟𝑡𝑎 → 𝑏𝑎𝑟𝑟𝑎𝑠 #6 𝑐𝑎𝑑𝑎 18 𝑐𝑚

𝐵𝑜𝑡𝑡𝑜𝑚: 𝐷𝑖𝑟𝑒𝑐𝑐𝑖𝑜𝑛 𝑙𝑎𝑟𝑔𝑎 → 𝑏𝑎𝑟𝑟𝑎𝑠 #6 𝑐𝑎𝑑𝑎 20 𝑐𝑚

 Viga de cimentación

Zona de confinamiento

𝐿𝑜 = 100 𝑐𝑚

Separación de estribos zona confinada

𝑆𝑐 = 10 𝑐𝑚

Separación de estribos zona no confinada

𝑆𝑐 = 12 𝑐𝑚

63
11. LONGITUD DE DESARROLLOS Y GANCHOS PARA LOS ELEMENTOS

ESTRUCTURALES

La longitud de desarrollo, Ld, se calcula de acuerdo con lo especificado por la NSR-

10, Sec.C.12.2.2.

Longitudes de traslapo Clase B para barras rectas y corrugadas a tracción,

estructuras con demanda mínima, DMI; y demanda moderada, DMO, de ductilidad,

Yt = 1.0, Ye = 1.0

64
12. DISEÑO DE ELEMENTOS NO ESTRUCTURALES

Los elementos no estructurales se deben clasificar teniendo en cuenta el grado de

desempeño así (A.9.2.1):

Superior: Es aquel en el cual el daño que se presenta en los elementos no

estructurales es mínimo y no interfiere con la operación de la edificación debido a la

ocurrencia del sismo de diseño.

Bueno: Es aquel en el cual el daño que se presenta en los elementos no

estructurales es totalmente reparable y puede haber alguna interferencia con la

operación de la edificación con posterioridad a la ocurrencia del sismo de diseño.

Bajo: Es aquel en el cual se presentan daños graves en los elementos no

estructurales, inclusive no reparables, pero sin desprendimiento o colapso, debido

a la ocurrencia del sismo de diseño.

Las edificaciones como mínimo debe cumplirse el grado de desempeño de la

siguiente tabla.

Tabla A.9.2-1

Para el diseño de estos elementos se deben tener en cuenta las fuerzas sísmicas

horizontales reducidas de diseño que actúan sobre cualquier elemento no

estructural utilizando la siguiente ecuación (A.9.4.2):

65
Los parámetros que intervienen en esta ecuación son:

 Aceleración en el punto de soporte del elemento, ax

 Amplificación dinámica del elemento no estructural, ap

 Capacidad de disipación de energía en el rango inelástico del elemento no

estructural, Rp

 La masa del elemento, Mp

La aceleración en el punto de soporte ax, se calcula con las siguientes ecuaciones,

(A.9.4-2), en donde Sa es para las dos direcciones en planta de la estructura y se

debe emplear el mayor valor de Sa.

El coeficiente de amplificación dinámica del elemento no estructural ap y la

capacidad de disipación de energía en el rango inelástico del elemento no

estructural Rp, se obtienen de la siguiente tabla:

66
Tabla A.9.5-1

Para obtener el Rp de esta tabla se deben tener en cuenta algunos de los tipos de

anclaje empleados en el medio y su grado de aceptabilidad (A.9.4.9):

 Especiales (Rp=6) - Se trata de anclajes diseñados siguiendo los requisitos

del Título F para estructuras acero estructural para capacidad de disipación

especial (DES). Deben cumplirse todos los requisitos dados allí para permitir

este valor de Rp. (A.9.4.9.1).

67
 Dúctiles (Rp=3) - Cuando el anclaje se realiza por medio de anclajes

profundos que emplean químicos (epóxicos), anclajes profundos vaciados en

el sitio, o anclajes vaciados en el sitio que cumplen los requisitos del Capítulo

C.21. No se permiten los pernos de expansión ni anclajes colocados por

medios explosivos (tiros). Anclajes profundos son aquellos en los cuales la

relación entre la porción embebida al diámetro del perno es mayor de 8. Este

tipo de anclajes debe emplearse cuando el elemento no estructural es dúctil.

(A.9.4.9.2).

 No dúctiles (Rp=1,5) - Cuando el anclaje se realiza por medio de pernos de

expansión, anclajes superficiales que emplean químicos (epóxicos), anclajes

superficiales vaciados en el sitio, o anclajes colocados por medio explosivos

(tiros). Anclajes superficiales son aquellos en los cuales la relación entre la

porción embebida al diámetro del perno es menor de 8. Dentro de este tipo

de anclajes se encuentran las barras de acero de refuerzo con ganchos en

los extremos que se embeben dentro del mortero de pega de la mampostería.

Este tipo de anclajes se permiten cuando el elemento no estructural no es

dúctil. Si se utilizan en elementos no estructurales dúctiles, éstos deben

diseñarse para el mismo valor de Rp=1,5. (A.9.4.9.3).

 Húmedos (Rp=0.5) - Cuando se utiliza mortero, o adhesivos que pegan

directamente al mortero o al concreto, sin ningún tipo de anclaje mecánico

resistente a tracción. (A.9.4.9.4).

68
Estos son los principales parámetros a tener en cuenta en el diseño de elementos

no estructurales.

Para nuestro trabajo se diseña dos tipos de muros:

 un muro soportado en la base y en el extremo superior (fachada)

 un muro de antepecho y parapeto

A continuación, se presentan los resultados obtenidos y los detalles constructivos

se plasman en los planos estructurales.

 Muros de fachada y de antepechos y parapetos

ANTEPECHOS
MUROS FACHADA
Y PARAPETOS
hn (m) 15.10 15.10
heq (m) 11.33 11.33
Sa 0.9 0.9
As 0.3 0.3
ap 1 2.5
Rp 3 1.5
Aa 0.3 0.3
Coeficiente Importancia 1 1
Peso especifico (ton/m3) 1.85 1.85
Espesor muro (m) 0.15 0.15
Peso muro (ton/m2) 0.28 0.28
Longitud muro (m) 5.61 5.61
Esfuerzo acero (Mpa) 170 170
b (m) 0.15 0.15
h (m) 0.15 0.15
Separacion columneta (m) 2.20 2.00

69
 Columnetas muros de fachada

h long d. barra
losa hx Fp muro Momento Cortante Momento Cortante acero diam #3 Nº
ax chequeo
barras
Nº m ton/m/m m ton-m/m ton/m ton-m ton m cm cm
5 15.10 1.20 0.11 0.04 2.0 0.22 0.22 1.25 1.25 1.95 0.90 0.95 1
4 12.50 0.99 0.09 0.04 2.5 0.29 0.23 1.61 1.29 2.45 0.98 0.95 1
3 9.50 0.80 0.07 0.04 2.5 0.23 0.19 1.30 1.04 2.45 0.91 0.95 1
2 6.50 0.64 0.06 0.04 2.5 0.19 0.15 1.04 0.84 2.45 0.85 0.95 1
1 3.50 0.49 0.04 0.04 3.0 0.20 0.13 1.13 0.76 2.95 0.87 0.95 1

Con los resultados obtenidos se puede utilizar una barra Nª 3 en cada columneta, la separación máxima de estas es de

2.20m y debe tener unas dimensiones de 0.15mx0.15m. El acero requerido en cada columneta deberá anclarse en la base

y en la parte superior a la viga del piso, en los lugares en donde este muro no coincida con la viga se debe anclar a la losa.

Cada cuatro hiladas de ladrillo se debe colocar una barra Nª 2 ancladas a las columnetas que amarran el muro.

70
 Columnetas muros de antepechos y parapetos

h long d. barra
losa hx Fp muro Momento Cortante Momento Cortante acero diam #2 Nº
ax chequeo
barras
Nº m ton/m/m m ton-m/m ton/m ton-m ton m cm cm
5 15.10 1.20 0.56 0.04 1.6 0.71 0.89 3.99 4.98 1.60 1.34 1.27 2
4 12.50 0.99 0.46 0.04 1.6 0.59 0.74 3.30 4.12 1.60 1.26 1.27 2
3 9.50 0.80 0.37 0.04 1.6 0.48 0.59 2.67 3.33 1.60 1.17 1.27 2
2 6.50 0.64 0.30 0.04 1.6 0.38 0.48 2.14 2.68 1.60 1.09 1.27 2
1 3.50 0.49 0.22 0.04 1.6 0.29 0.36 1.61 2.02 1.60 0.99 1.27 2

Los resultados nos dicen que se puede utilizar dos barras Nº 2 en cada columneta, además de utilizar un estribo en S del

mismo diámetro del acero longitudinal cada 0.2m. La separación máxima de las columnetas es de 2.0m y debe tener unas

dimensiones de 0.15mx0.15m. El acero requerido en cada columneta deberá anclarse en la base a la viga del piso, en los

lugares en donde este muro no coincida con la viga se debe anclar a la losa. En la parte superior del se debe construir una

vigueta con dos barras Nº 3 y así poder confinar el muro.

71
13. REQUISITOS PROTECCIÓN CONTRA INCENDIOS.

 Protección pasiva

La edificación en análisis pertenece al grupo de ocupación R y así mismos al

subgrupo de ocupación R-2, en donde se encuentran las edificaciones o espacios

empleados principalmente como vivienda, o como dormitorio de tres o más familias,

o de más de 20 personas.

Tabla J.1.1-1 o K.2.1-1

Además de nuestra edificación se clasificará según la función del riesgo de pérdidas

de vidas humanas o amenaza de combustión en la categoría II de edificaciones de

riesgo intermedio.

Tabla J.3.3-1

72
Los elementos estructurales y demás elementos de la construcción deberán tener

como mínimo las resistencias al fuego normalizado.

Tabla J.3.4-3

A continuación, se presenta unas tablas para determinar la resistencia al fuego de

los elementos estructurales según el decreto 92 de enero de 2011.

Para vigas se debe utilizar las dimensiones mínimas según el grado de disipación

de energía, garantizando un recubrimiento mínimo de 4cm para resistir el fuego

durante 2 horas y un recubrimiento de 6cm adecuado hasta 3 horas.

La siguiente tabla es para columnas garantizando un recubrimiento mínimo de 4cm

adecuado para resistir el fuego durante 3 horas

Para losas se debe seguir las siguientes dimensiones con un recubrimiento mínimo

de 2cm para resistir el fuego durante 1 hora y un recubrimiento mayor a 2,5cm

adecuado para más de 2 horas.

73
Para muros estructurales se debe garantizar los mismos recubrimientos que los de

las losas además de cumplir con las dimensiones mínimas de la tabla siguiente.

 Protección activa

Se deben instalar dispositivos de detección y la alarma temprana contra incendios

en los siguientes casos, según el grupo de ocupación.

Tabla J.4.2-1

Además, se deben instalar rociadores automáticos para edificaciones clasificadas

en el grupo de ocupación R2 cuya altura exceda 7 pisos, en las zonas comunes

excepto las escaleras y en toda el área para uso como estacionamiento ubicado

bajo el edificio (J.4.3.8.1). También se deben instalar tomas fijas para bomberos y

mangueras para extinción de incendios en edificaciones que tengan más de 5 pisos

o de mayores a 15m (J.4.3.8.2). Por último, toda edificación clasificada en este

grupo de ocupación debe tener extintores portátiles de fuego (J.4.3.8.3).

74
14. CONCLUSIONES

 El estudio del diseño arquitectónico es fundamental para entender las

posibles distribuciones de columnas y muros estructurales, este también

puede determinar las dimensiones máximas del modelo estructural, en el

presente trabajo el espacio limitado de entradas, salidas y pasillos determino

el dimensionamiento máximo de las secciones de columnas.

 El análisis de cargas debe realizarse con detallamiento, ya que de este

dependerá todos los resultados obtenidos, y un pequeño cambio podría

afectar todo el diseño y resultados obtenidos.

 Es de vital importancia determinar las cargas muertas que harán parte de la

masa de tu estructura, ya que de estas dependerá el periodo fundamental de

tu estructura.

 Las cargas de viento deben realizarse para todo tipo de estructuras, en el

presente trabajo, para el cálculo, fue fundamental conocer la topografía y

ubicación del proyecto, sin embargo, estas fuerzas resultaron por debajo de

la carga mínima de 0.4 KN/m2 con la cual se trabajó.

 Los requisitos de la norma NSR-10 para el acero de refuerzo se cumplieron

con satisfacción, se obtuvieron resultados muy similares, hubo cumplimiento

de los aceros mínimos y máximos. Solo el diseño por cortante de las

columnas y el cortante en los nudos fue diferente, el software trabajo con

unos cortantes más pequeños, sin embargo, los resultados no fueron

controlados por este criterio y dio resultados aceptables.

75

You might also like