Test Report on CBR (AASHTO T193)

Penetration Mould-1
(mm) Dial Reading Load (kN)
0 0 0.00
0.25 15 0.30
0.50 25 0.50
0.75 33 0.66
1.00 42 0.84
1.25 50 1.01
1.50 60 1.21
1.75 66 1.33
2.00 76 1.53
2.25 85 1.71
2.50 95 1.91
2.75 104 2.09
3.00 113 2.27
3.25 123 2.47
3.50 132 2.65
3.75 141 2.84
4.00 150 3.02
4.25 160 3.22
4.50 170 3.42
4.75 180 3.62
5.00 192 3.86
5.25 196 3.94
5.50 200 4.02
5.75 204 4.10
6.00 209 4.20
6.25 213 4.28
6.50 217 4.36
6.75 221 4.44