MTL Cabinets and Enclosures

for MTL8000 and MTL8800L

Cabinets and Enclosures- overview 4.2

Standard Cabinet Specification 4.3

C8000 System for MTL8000 4.4

E8000S & E8000D Enclosures for MTL8000 4.5

E8800L Enclosures for MTL8800L 4.6

ENCLOSURES
CABINETS &

MTL Power Court, Luton, Bedfordshire, England LU1 3JJ


Tel: +44 (0)1582 723633 Fax +44 (0)1582 422283
E-mail: enquiry@mtl-inst.com Web site: http://www.process-io.com
MTL Cabinets and Enclosures - Overview

From components to Standard system Telematic range


complete solutions . . A standard system and enclosure is The Telematic range of surge protection
available for the MTL8000 and MTL8800L devices (SPDs) is a further option to
ranges. This provides an enclosure neutralise the effect of high voltage spikes
containing the Process I/O equipment, that can be induced by lightning and heavy
Since the early 1970’s MTL has
power supplies and their internal wiring, duty industrial machinery. Bearing in mind
acquired international recognition field-wiring trunking and tagging and any the high cost of downtime for equipment
for individual Intrinsic Safety necessary isolation devices replacement, the Telematic range of SPDs
components. This reputation has represents a cost effective safeguard and
now been further enhanced by Overall package inexpensive insurance.
MTL Process Automation’s range The overall package includes all specified
of Process I/O products. To components, followed by a full, in-house
Quotations
simplify the system integration inspection. Each cabinet or enclosure is Quotations for these standard system
supplied with full documentation showing solutions are available from your local MTL
process, MTL can offer any of this
the wiring configuration, the internal layout, office. The standard products are designed
equipment ready assembled in a a bill of materials and details of the power to meet most customer’s needs but your local
range of standard cabinets or distribution. MTL’s ISO9001 certification sales office will also be pleased to quote for
enclosures. ensures that you receive high quality any special requirements.
engineering to recognised standards with
prompt delivery times. For more information about individual
Process I/O systems or IS barrier components, please refer to the MTL
and isolator components can be Traditional MTL interface IS catalogue.
provided pre-assembled in a ranges
range of standard cabinets and Traditional MTL interface ranges –
enclosures. Previously only avail- MTL7000 and MTL4700 barriers, MTL4000
able as custom-made assemblies, and MTL5000 galvanic isolators and
MTL can now offer these from a MTL800 multiplexers are also available,
integrating the functions of an IS interface
sophisticated, yet cost effective,
cabinet and a marshalling cabinet into one.
standard range. Each system is designed to bring out the
specific application features of each range.

Also available is the extensive


ENCLOSURES

range of Telematic products to


CABINETS &

protect control signal, coax and


video signal cables and equip-
ment, power lines and networks.

MTL Power Court, Luton, Bedfordshire, England LU1 3JJ


Tel: +44 (0)1582 723633 Fax +44 (0)1582 422283
E-mail: enquiry@mtl-inst.com Web site: http://www.process-io.com
MTL Cabinets and Enclosures

Standard cabinet specification

◆ 24 Vdc, 25A power supply*


◆ 230 Vac top mounted cooling fan
◆ Dual access (front and rear doors)
◆ Two air filters
◆ Drawing pocket
◆ Multiple earth bars
* 50A or redundant power supply available on
request

SPECIFICATION

Cabinet make & type: .....................................Rittal PS4808


Dimensions: ..800 (w) x 800 (d) x 2000 (h) (plus 100mm plinth)
Cabinet colour: ........................................................RAL7032
Plinth colour: ...........................................................RAL7022

800

Power supply 1

Power supply 2

Fan
Name plate

ENCLOSURES
CABINETS &
Top View
Door handle
2000

Drawing pocket Foundation Plan

Cable retainers
750

(mounted in plinth)
Air filter
(front and
back door)

Plinth 800
100

Front View

For more information about MTL systems, please contact your local MTL office.

MTL Power Court, Luton, Bedfordshire, England LU1 3JJ


Tel: +44 (0)1582 723633 Fax +44 (0)1582 422283
E-mail: enquiry@mtl-inst.com Web site: http://www.process-io.com
MTL Cabinets and Enclosures

C8000 floor mounting enclosure system for MTL8000 Series Process I/O

◆ High packing density


◆ No external barriers or isolators
◆ Hot swapping facility
◆ 6mm effective width per channel

The MTL8000 system can be connected to all major fieldbus types


and allows complete access to information from both smart and non
smart field devices. MTL8000 Series offers genuine process control
I/O features and data integrity. As well as real field mounting
capability, MTL8000 Series gives customers the benefit of greatly
reduced installed cost. Cabling and interconnections are both
minimised, and extra plant security, local fail-safe and preventive
maintenance characteristics combine to make this a unique and
reliable form of process control.

OUTLINE DESCRIPTION
of fully equipped system

MTL8000 Series modules ........................mounted on carriers


Mounting ..................................................................DIN rail
Number of channels
in horizontal installation ......................................................672
in vertical installation ........................................................1024
Wiring ...................................................................................
Field wiring is connected to integral field terminal blocks. A single
or dual communication cable is connected to the safe-area side of
ENCLOSURES
CABINETS &

the carrier.
Surge protection devices ....................................................
These devices can be installed to safeguard system integrity and
increase process reliability.
Options ................................................................................
Systems are available for horizontal or vertical mounting,
depending on packing density and operational temperature
requirements.
Note: Both standard system configurations may be used for gener-
al purpose, Zone 2, Zone 1 and Zone 0 field wiring. For field
mounting, please refer to the section “Field Enclosures”.

ORDERING INFORMATION
MTL8000 System ......................................................C8000
Options .................................................................................
Redundant power supply for carrier and bussed field power, surge
protection and loop disconnect facility

MTL Power Court, Luton, Bedfordshire, England LU1 3JJ


Tel: +44 (0)1582 723633 Fax +44 (0)1582 422283
E-mail: enquiry@mtl-inst.com Web site: http://www.process-io.com
MTL Cabinets and Enclosures

E8000S & E8000D wall mounting field enclosures for


MTL8000 Series Process I/O

◆ Designed specifically for field installation


◆ Corrosion resistant construction
◆ Hot swapping facility
◆ Ideal for all process I/O applications

Standard field enclosures are available for MTL8000 Series. These


enclosures are rated IP65 and are suitable for mounting in the field.
The “standard” design ensures adequate heat dissipation and is
suitable for input from general purpose and Zone 2 as well as from
Zone 1/Zone 0 areas. Single and two carrier designs are available.
Both designs provide a window through which status LEDs on the
modules, BIM and power supply can be seen. Designs are available
with powder-coated mild steel, stainless steel or polycarbonate
material as the enclosure material.

OUTLINE DESCRIPTION
of fully equipped system

Items provided .................................................Fitted DIN rail


..........................................................................Cable trunking
Permitted location ..................................................Safe area
.........................................................................Europe Zone 2
...........................................USA & Canada, Class 1, Division 2
...........................................excluding Class 2, Division 2 (dusts)

ENCLOSURES
Ambient temperature limits ................................................

CABINETS &
Can be fully loaded without exceeding the temperature rating of the
installed modules.
Surge protection devices ....................................................
These devices can be installed to safeguard system integrity and
increase process reliability.
Dimensions
E8000S............................................380 (w) x 210 (d) x 600 (l)
E8000D ...........................................700 (w) x 210 (d) x 760 (l)
Options ................................................................................
Ex ‘p’ purged enclosures with leakage compensators for mounting
in Zone 1 are available. Redundant power supplies are also an
option.

ORDERING INFORMATION
Single carrier enclosure ..........................................E8000S
Two carrier enclosure: ............................................E8000D
Options .................................................................................
Powder-coated mild steel, stainless steel or polycarbonate enclosure
material, surge protection, purged enclosure with leakage
compensators, Ex ‘p’ enclosure and/or redundant power supply.

MTL Power Court, Luton, Bedfordshire, England LU1 3JJ


Tel: +44 (0)1582 723633 Fax +44 (0)1582 422283
E-mail: enquiry@mtl-inst.com Web site: http://www.process-io.com
MTL Cabinets and Enclosures

E8800L wall mounting field enclosures for MTL8800L Series

◆ Zone 1 or 2/Division 1 or 2 hazardous area or


general purpose mounting
◆ Reduced installation costs
◆ Flexible system design
◆ High system availability

MTL8800L Series distributed I/O systems provide an intelligent


interface between field-mounted instrumentation and a process
industry control system. The I/O blocks are capable of being
mounted in Zone 1/Division 1 hazardous areas; connecting via a
fieldbus to the bus interface in the safe area. Whether an
existing system or a new one is installed, MTL8800L Series connect
field sensors and actuators to the system via one of a number of
standard fieldbuses or Local Area Networks (LANs).

OUTLINE DESCRIPTION
of fully equipped system

Mounting ...................................................................DIN rail


Number of I/O blocks .......................................................1
Permitted location
The I/O blocks are capable of being mounted in Zone1/Division1
hazardous areas. The MTL8800L Series are usually mounted in a
field enclosure to provide environmental protection.
Wiring ..................................................................................
Terminal blocks are provided on hazardous area side for
ENCLOSURES
CABINETS &

marshalling
Surge protection devices ....................................................
These devices can be installed to safeguard system integrity and
increase process reliability.

ORDERING INFORMATION

MTL8800 Enclosures ................................................E8800L


Options .......................IS power distribution for DO, AI and AO
...................................................2,3 or 4 wire RTD connections