You are on page 1of 2

ES STRUCTURAL CONSULTANT STRUCTURAL DESIGN CALCULATION

Date : 03-Apr-18
Part : Corridor slab Number: Element : Solid Slab
Project :

Material Properties
Concrete fcu : 40 MPa
Steel strength fy : 500 MPa
concrete cover : 35 mm
Unit weight of concrete : 25 kN/m3

Geometry
Thickness of slab
t : 125 mm
effective depth of slab
Length of Slab : 2.40 m d : 90 mm
Width of Slab : 1.00 m b : 1000 mm

Loading
Dead load on slab : 3.5 kPa
Live load on slab : 4.0 kPa

DL 6.63 kN/m
LL 4.00 kN/m

2.4 m

Self weight of slab : 3.13 kN/m


Suiperimposed dead load : 3.5 kN/m
Superimposed live load : 4.0 kN/m

Analysis
The maximum bending moment in service will be due to the ultimate loads,
1.5DL+1.5LL wu : 15.94 kN/m

BM Mu : 11.5 kNm/width Mu : 11.5 kNm/m


Shear Vu : 19.1 kN/width Vu : 19.1 kN/m width

Flexure Design
Mu : 0.87 fy Ast d (1- Ast fy/(fck b d))
effective width available
b : 1000 mm d : 90 mm

Mu,lim : 0.133 fck bd2 : 43.1 kNm


> 11.48 kNm, hence compression reinforcement is not required.
Calculating the required area of steel,
2
5.438 Ast - 4E+04 Ast = 1E+07

Solving the above equation,


2
Ast : 306.1 mm
Minimum reinforcement required for beam as per IS 456, Sec.26.5.1.1
: 0.170%
ES STRUCTURAL CONSULTANT STRUCTURAL DESIGN CALCULATION

Date : 03-Apr-18
Part : Corridor slab Number: Element : Solid Slab
Project :

As,min : 153 mm2 Ast,req : 306.1 mm


2

Provide main reinforcement as below


2
10 mm @ 200 mm c/c Ast,Pro : 392.7 mm
ρ : 0.44%
Distribution Steel
Ast : 0.12 bt (IS456-Sec 26.5.2.1)
: 150 mm2 per m width
Distribution reinforcement as below
2
8 mm @ 250 mm c/c Ast,Pro : 201.1 mm
Compression reinforcement
mm @ 150 mm c/c Ast',Pro : 0 mm2

Check for Shear


Shear stress τv : Vu/(bd)
effective width available
b : 1000 mm d : 90 mm

2
τv : 0.044 N/mm
Shear strength provided by concrete based on the available reinforcement,
2
τc : 0.43 N/mm (IS 456-Table-19)
> τv, Hence shear reinforcement is not required.

Check for Deflection


Actual L/d ratio (L/d)act : 26.67

deflection limit, L/d : 20.0 (IS456-Sec-23.2.1)

Modification factor for tension reinforcement (IS456-Fig-4)


ρ : 0.44 percent
Ast,req : 306.1 sqmm
Ast,Pro : 392.7 sqmm

fs : 0.58 fy (Ast,req/Ast,pro) (IS456-Fig-4)


2
fs : 226.1 N/mm

Therefore, modification factor for tension reinforcement


m1 : 1.41

Modification factor for compression reinforcement (IS456-Fig-5)


ρ' : 0.00 percent

m2 : 1.00 (IS456-Fig-5)

(L/d)allow : 28.2
> 26.67, deflection within limit. Hence safe.