HIGH VOLUME / PM10 DATA RECORD

Site / Station : Lab 17

Sample Date : 12/2

Collection Date : 13/2

Time : 24 Hours

Initial Filter Weight : 4.31g

Gross Filter Weight : 4.33g

Net Particulate Weight (A) : 0.02g

Flow Rate (Using air flow : 40 ft3/min


meter)
Running Time Meter (Initial) : 9.20 am

(Final) : 9.20 am

Total Sample Time : 1720 – 280 = 1440min = 24 hours

Total Air Volume : (40 X 1440) X 0.028 = 1612.8 m3

Particulate Concentration : A g / 1612.8 m3 = 6.20µg/m3

Exposed Area : 20.5 X 27 = 553.5 cm2


Plumbum test using Atomic Absorption Spectrophotometer (AAS):

Sample Mean SD RSD Replicates Replicates Replicates


(%)
Blank 0.319 0.0017 0.5 0.321 0.317 0.319
Autozero Performed
Standard 0.107 0.0028 2.7 0.104 0.110 0.106
1
Standard 1 Applied
Standard 0.137 0.0007 0.5 0.138 0.137 0.136
2
Standard 2 Applied
Standard 0.166 0.0013 0.8 0.166 0.168 0.165
3
Standard 3 Applied
Corr. Coef.: 0.831939 Slope: 0.06567 Intercept: 0.0000
Sample 0.027 0.0178 66.7 0.047 0.014 0.020
001
Table 1: The Result obtained from Atomic Absorption Spectrophotometer

Figure 1: The Graph Obtained from Atomic Absorption Spectrophotometer test