INFORMACION HIDROLOGICA

Estación: LUMBA

Precipitación Máxima en 24 horas mm

Año Enero Febrero Marzo Abril Mayo Junio


1997 14.3 19.7 26.2 32.7 23.1 7.9
1998 4.1 26.9 31.5 38.6 35.9 8.7
1999 19.7 35.7 18.3 17.7 23.8 23.4
2000 8.7 11.0 32.2 22.0 14.4 36.8
2001 7.2 35.9 23.2 13.2 6.8 0.8
2002 10.5 18.8 18.5 41.8 17.7 4.4
2003 9 7.1 54.4 5.1 20.5 11.8
2004 2.8 6.9 16.7 18.8 124.3 20.4

Maximo 19.7 35.9 54.4 41.8 124.3 36.8


Minimo 2.8 6.9 16.7 5.1 6.8 0.8
Promedio 9.5 20.3 27.6 23.7 33.3 14.3
ORMACION HIDROLOGICA
UTM Norte 9419408.448 Dpto Amazonas
Este 822460.943 Prov Bagua
Altitud 1050 msnm Dist Aramango

Julio Agosto Septiembre Octubre Noviembre Diciembre TOTAL MAXIMA ANUAL


4.2 11.9 2.8 14.6 22.2 7.4 187.0 32.7
1.9 8.6 8.8 38.9 8.4 15.1 227.4 38.9
6.6 20.0 29.3 7.0 14.8 19.0 235.3 35.7
11.2 12.0 7.4 11.7 21.4 19.6 208.4 36.8
7.2 2.2 23.0 14.0 14.5 55.5 203.5 55.5
25.3 0.6 8.2 41.7 36.5 6.5 230.5 41.8
4.7 3.3 65.7 14.5 10 19.2 225.3 65.7
13.7 11.3 4.3 18.9 34.8 11.9 284.8 124.3

25.3 20.0 65.7 41.7 36.5 55.5 124.3


1.9 0.6 2.8 7.0 8.4 6.5 32.7
9.4 8.7 18.7 20.2 20.3 19.3 225.3
PROMEDIO
15.6
19.0
19.6
17.4
17.0
19.2
18.8
23.7
INFORMACION HIDROLOGICA
Estación : DURAND

Parametro: Precipitación Máxima en 24 horas mm

Año Enero Febrero Marzo Abril Mayo Junio


1997 6.7 31.0 12.0 23.0 43.2 22.3
1998 28.7 32.5 28.8 52.5 45.3 36.5
1999 45.5 41.0 16.4 65.5 101.0 51.5
2000 19.0 36.8 60.0 39.5 55.5 77.0
2001 15.5 8.6 3.8 31.6 43.0 32.2
2002 20.0 18.5 20.3 42.5 26.0 29.5
2003 19.5 30.5 27.0 18.0 40.0 46.5
2004 38.2 10.5 26.0 13.0 109.0 44.6

Maximo 45.5 41.0 60.0 65.5 109.0 77.0


Minimo 6.7 8.6 3.8 13.0 26.0 22.3
Promedio 24.1 26.2 24.3 35.7 57.9 42.5
ORMACION HIDROLOGICA
Latitud 9428675.599 Dpto Amazonas
Longitud 838956.083 Prov Bagua
Altitud 650 msnm Dist Aramango

Julio Agosto Septiembre Octubre Noviembre Diciembre Sub Total MAXIMA ANUAL
53.0 11.2 10.4 3.3 3.2 6.4 225.7 53.0
55.8 26.5 23.0 75.0 18.0 16.0 438.6 75.0
47.5 37.0 28.0 68.0 17.5 15.5 534.4 101.0
38.0 45.0 16.8 22.4 21.5 93.9 431.5 93.9
24.0 20.7 20.0 38.0 28.0 32.3 297.7 43.0
27.0 16.5 19.0 26.0 30.2 12.3 287.8 42.5
73.8 21.0 32.0 34.5 59.0 24.0 425.8 73.8
70.2 33.2 18.0 19.5 36.5 35.9 418.7 109.0

73.8 45.0 32.0 75.0 59.0 93.9 109.0


24.0 11.2 10.4 3.3 3.2 6.4 42.5
48.7 26.4 20.9 35.8 26.7 29.5 398.8

109
101
93.9
75
73.8
53
43
42.5
Total PROMEDIO
225.7 19.9
438.6 37.3
534.4 44.4
525.4 46.0
297.7 25.7
287.8 24.3
425.8 36.9
454.6 37.9
INFORMACION HIDROLOGICA
Estación : PUERTO PACUY

Parametro: Precipitación Total Mensual mm

Año Enero Febrero Marzo Abril Mayo Junio Julio


1997 80.4 54.9 30.7 94.2 58.3 31.6 16.7
1998 34.6 49.9 26.7 47.9 76.1 50.6 23.5
1999 69.0 80.8 61.2 28.0 57.3 47.2 20.7
2000 22.3 60.7 66.9 99.8 38.2 40.0 30.7
2001 43.9 54.2 31.2 49.0 46.3 32.7 38.7
2002 31.7 35.5 44.3 29.5 45.4 21.5 48.0
2003 24.7 37 35.8 35.3 43.9 44.2 34.0
2004 60.2 28.3 41.3 37.0 46.0 26.2 33.8

Maximo 80.4 80.8 66.9 99.8 76.1 50.6 48.0


Minimo 22.3 28.3 26.7 28.0 38.2 21.5 16.7
Promedio 45.9 50.2 42.3 52.6 51.4 36.8 30.8
HIDROLOGICA
UTM: Norte: 9441002.258 Dpto Amazonas
Este: 841304.618 Prov Bagua
Altitud 400 msnm Dist Pacuy

Agosto Septiembre Octubre Noviembre Diciembre Total MAXIMA ANUAL PROMEDIO


42.4 32.8 52.1 67.2 37.8 599.1 94.2 49.9
9.7 46.1 55.1 29.9 35.2 485.3 76.1 40.4
24.5 27.8 38.2 23.4 67.2 545.3 80.8 45.4
27.0 64.0 26.8 20.5 37.5 534.4 99.8 44.5
20.0 28.3 48.4 40.3 44.8 477.8 54.2 39.8
21.3 18.5 43.0 67.7 30.8 437.2 67.7 36.4
30.5 36.1 79.0 28.2 42.7 471.4 79.0 39.3
31.6 37.7 53.5 77.0 69.4 542.0 77.0 45.2

42.4 64.0 79.0 77.0 69.4 99.8


9.7 18.5 26.8 20.5 30.8 54.2
25.9 36.4 49.5 44.3 45.7 511.6

99.8
94.2
80.8
79.0
77.0
76.0
67.7
54.2
INFORMACION HIDROLOGI
Estación : CHIRIACO

Parametro: Precipitación Máxima en 24 horas mm

Año Enero Febrero Marzo Abril Mayo Junio


1997 24.5 27.0 40.8 41.4 75.0 17.4
1998 34.0 50.8 35.0 54.0 64.0 30.0
1999 25.0 50.4 40.4 50.6 68.4 6.0
2000 35.5 36.0 60.5 100.0 50.0 36.0
2001 47.0 51.0 50.5 43.8 51.0 58.5
2002 35.5 40.0 40.2 50.0 70.0 56.0
2003 40 125 136.0 128.0 180.0 100.0
2004 61.2 64.5 23.5 36.2 111.6 114.0

Maximo 61.2 125.0 136.0 128.0 180.0 114.0


Minimo 24.5 27.0 23.5 36.2 50.0 6.0
ORMACION HIDROLOGICA
UTM Norte 9446259.099 Dpto Amazonas
Este 840084.618 Prov Bagua
Altitud 350 msnm Dist Chiriaco

Julio Agosto Septiembre Octubre Noviembre Diciembre Sub Total MAXIMA ANUAL
40.0 10.2 31.0 62.1 27.4 31.5 428.3 75.0
33.2 40.0 69.1 116.5 20.0 33.0 546.4 116.5
4.0 6.0 25.0 52.0 72.0 60.0 459.8 72.0
4.0 63.0 25.5 12.5 55.0 20.5 438.0 100.0
40.0 45.0 80.0 88.0 40.0 25.0 485.0 88.0
50.0 10.5 12.3 125.0 20.5 13.0 523.0 125.0
70.5 25.0 23.0 37.0 30.0 50.5 945.0 180.0
32.0 37.4 41.5 81.0 84.0 12.0 662.7 114.0

70.5 63.0 80.0 125.0 84.0 60.0


4.0 6.0 12.3 12.5 20.0 12.0
Total PROMEDIO
428.3 35.7
579.6 48.3
459.8 38.3
498.5 41.5
619.8 51.6
523.0 43.6
945.0 78.8
698.9 58.2
CALCULO DE DATOS FALTANTES POR EL METODO DE LOS PROMEDIOS
ESTACION DURAND
ESTACIONES
FECHA FALTANTE LUMBA DURAND PTO. PACUY CHIRIACO
Dic. 2000 19.60 X 37.50 20.50
TOTAL ANUAL 36.80 431.50 534.40 438.00
PRECIPITACION FALTANTE (X)= 92.50

CALCULO DE DATOS FALTANTES POR EL METODO DE LOS PROMEDIOS


ESTACION DURAND
ESTACIONES
FECHA FALTANTE LUMBA DURAND PTO. PACUY CHIRIACO
Dic. 2004 11.90 X 69.40 12.00
TOTAL ANUAL 124.30 418.70 542.00 662.70
PRECIPITACION FALTANTE (X)= 33.42

CALCULO DE DATOS FALTANTES POR EL METODO DE LOS PROMEDIOS


ESTACION PUERTO CHIRIACO
ESTACIONES
FECHA FALTANTE LUMBA CHIRIACO DURAND PTO PACUY
Jul. 1998 1.90 X 55.80 23.50
TOTAL ANUAL 227.40 546.40 438.60 485.30
PRECIPITACION FALTANTE (X)= 33.18

CALCULO DE DATOS FALTANTES POR EL METODO DE LOS PROMEDIOS


ESTACION PUERTO CHIRIACO
ESTACIONES
FECHA FALTANTE LUMBA CHIRIACO DURAND PTO PACUY
Marz. 2000 32.20 X 60.00 66.90
TOTAL ANUAL 208.40 438.00 431.50 534.40
PRECIPITACION FALTANTE (X)= 60.53
CALCULO DE DATOS FALTANTES POR EL METODO DE LOS PROMEDIOS
ESTACION PUERTO CHIRIACO
ESTACIONES
FECHA FALTANTE LUMBA CHIRIACO DURAND PTO PACUY
Feb. 2001 35.90 X 8.60 54.20
TOTAL ANUAL 203.50 485.00 297.70 477.80
PRECIPITACION FALTANTE (X)= 51.01

CALCULO DE DATOS FALTANTES POR EL METODO DE LOS PROMEDIOS


ESTACION PUERTO CHIRIACO
ESTACIONES
FECHA FALTANTE LUMBA CHIRIACO DURAND PTO PACUY
Abr. 2001 13.20 X 31.60 49.00
TOTAL ANUAL 203.50 485.00 297.70 477.80
PRECIPITACION FALTANTE (X)= 43.78

CALCULO DE DATOS FALTANTES POR EL METODO DE LOS PROMEDIOS


ESTACION PUERTO CHIRIACO
ESTACIONES
FECHA FALTANTE LUMBA CHIRIACO DURAND PTO PACUY
Nov. 2001 14.50 X 28.00 40.30
TOTAL ANUAL 203.50 485.00 297.70 477.80
PRECIPITACION FALTANTE (X)= 39.96

CALCULO DE DATOS FALTANTES POR EL METODO DE LOS PROMEDIOS


ESTACION PUERTO CHIRIACO
ESTACIONES
FECHA FALTANTE LUMBA CHIRIACO DURAND PTO PACUY
Abr. 2004 18.80 X 13.00 37.00
TOTAL ANUAL 284.80 662.70 418.70 542.00
PRECIPITACION FALTANTE (X)= 36.16
ANALISIS DE CONSISTENCIA

ANUAL ACUMULADO
AÑO
LUMBA DURAND PTO. PACUY CHIRIACO PP LUMBA DURAND
1997 187.00 225.70 599.10 428.30 360.03 1802.20 3190.00
1998 227.40 438.60 485.30 579.58 432.72 1615.20 2964.30
1999 235.30 534.40 545.30 459.80 443.70 1387.80 2525.70
2000 208.40 525.37 534.40 498.53 441.68 1152.50 1991.30
2001 203.50 297.70 477.80 619.75 399.69 944.10 1465.93
2002 230.50 287.80 437.20 523.00 369.63 740.60 1168.23
2003 225.30 425.80 471.40 945.00 516.88 510.10 880.43
2004 284.80 454.63 542.00 698.86 495.07 284.80 454.63
5000.00 ANALISIS DE CONSIST
ACUMULADO
PTO. PACUY CHIRIACO PPA R² = 0.9923947166
4500.00 ANALISI DE CONSISTENCIA
4092.50 4752.82 3459.38 LUMBA
3493.40 4324.52 3099.36 4000.00 Linear (ANALISI DE
R² = 0.9967659802
CONSISTENCIA LUMBA)
3008.10 3744.94 2666.64
3500.00 ANALISIS DE CONSISTENCIA
2462.80 3285.14 2222.94 DURAN
1928.40 2786.61 1781.26 3000.00 Linear
R² =(ANALISIS DE
0.99353855
1450.60 2166.86 1381.57 CONSISTENCIA DURAN)
ANALSIS DE CONSISTENCIA PTO
1013.40 1643.86 1011.95 2500.00 PACUY
542.00 698.86 495.07
2000.00
R² = 0.9993467244
1500.00

1000.00

500.00

0.00
0.00 500.00 1000.00 1500.00
ANALISIS DE CONSISTENCIA ESTACION DURAND
R² = 0.9923947166
ANALISI DE CONSISTENCIA
LUMBA
Linear (ANALISI DE
R² = 0.9967659802
CONSISTENCIA LUMBA)
ANALISIS DE CONSISTENCIA
DURAN
Linear
R² =(ANALISIS DE
0.99353855
CONSISTENCIA DURAN)
ANALSIS DE CONSISTENCIA PTO
PACUY

R² = 0.9993467244

500.00 1000.00 1500.00 2000.00 2500.00 3000.00 3500.00 4000.00


PROMEDIO ARITMETICO

ESTACION PRECIPITACION (mm) ESTACION


LUMBA 225.275 DURAND
DURAND 398.75 CHIRIACO
PTO. PACUY 511.5625 PTO. PACUY
CHIRIACO 0 LUMBA
AREA TOTAL

Pmed= 303.4375 mm

ISOYETAS

ISOYETAS (mm) AREA

150 - 200 7342395.08


200 - 300 42829542.923
300 - 400 93464550.176
400 - 500 47537986.83
500 - 600 57300301.586
600 - 650 81076797.47
TOTAL AREA 329552255.299
POLIGONO DE THIESSEN

AREA % PRECIPITACION Pmedi


A1 31520858.984 9.56 398.75 38.1394522956
A2 57159755.805 17.34 0 0
A3 70505871.58 21.39 511.5625 109.445950837
A4 170365768.927 51.70 225.275 116.4584613758
AREA TOTAL 329552255.299 100.00 TOTAL 264.0438645 mm

31.520858984
57.159755805
70.505871583 329552.255
170.365768927 329552.255
329.552255299
ISOYETAS

PORCENTAJE DE AREA ISOYETA Pmed


ENTRE CURVAS PROMEDIO
2.23 175 3.8989845111
13.00 250 32.4907068866
28.36 350 99.2637496348
14.43 450 64.9126010504
17.39 550 95.6302539751
24.60 625 153.7631668562
100.00 TOTAL 449.959463 mm
38.1394523
APLICANDO METODO DE THIESSEN

AREAS DE INFLU
AÑO Nº DATOS LUMBA -A DURAN -B PACUY -C CHIRIACO -D A (Km2)
1997 1 124.3 109 99.8 180 170.37
1998 2 65.7 101 94.2 125 170.37
1999 3 55.5 93.9 80.8 116.5 170.37
2000 4 41.8 75 79.0 114 170.37
2001 5 38.9 73.8 77.0 100 170.37
2002 6 36.8 53 76.0 88 170.37
2003 7 35.7 43 67.7 75 170.37
2004 8 32.7 42.5 54.2 72 170.37

DISTRIBUCION NORMAL

AÑO Nº DATOS Pmed. (mm) F(X) EMPIRICA NORMAL NORMAL


1997 1 127.260 0.9841 0.1111 0.0159 0.0952
1998 2 85.462 0.7130 0.2222 0.2870 0.0648
1999 3 75.168 0.5682 0.3333 0.4318 0.0984
2000 4 65.459 0.4222 0.4444 0.5778 0.1333
2001 5 60.989 0.3573 0.5556 0.6427 0.0871
2002 6 55.618 0.2846 0.6667 0.7154 0.0488
2003 7 50.062 0.2177 0.7778 0.7823 0.0045
2004 8 45.055 0.1661 0.8889 0.8339 0.0550

MEDIA = 70.634 MAXIMO = 0.133


DESV. EST. = 26.375 CRITICO = 0.481
ACEPTADA

LOG NORMAL 2 PARAMETROS

AÑO Nº DATOS Pmed. (mm) y = lnx F(x) EMPIRICA LN2


1997 1 127.260 4.8462 0.9731 0.1111 0.0269
1998 2 85.462 4.4481 0.7670 0.2222 0.2330
1999 3 75.168 4.3197 0.6340 0.3333 0.3660
2000 4 65.459 4.1814 0.4705 0.4444 0.5295
2001 5 60.989 4.1107 0.3870 0.5556 0.6130
2002 6 55.618 4.0185 0.2861 0.6667 0.7139
2003 7 50.062 3.9133 0.1890 0.7778 0.8110
2004 8 45.055 3.8079 0.1152 0.8889 0.8848

MEDIA = 4.206 MAXIMO =


DESV. EST. = 0.332 CRITICO =
LOG NORMAL 3 PARÁMETROS

AÑO Nº DATOS Pmed. (mm) y = ln (x-a) F(x) EMPIRICA LN3


1997 1 127.260 4.493 0.9454 0.1111 0.0546
1998 2 85.462 3.863 0.7901 0.2222 0.2099
1999 3 75.168 3.619 0.6912 0.3333 0.3088
2000 4 65.459 3.317 0.5474 0.4444 0.4526
2001 5 60.989 3.141 0.4586 0.5556 0.5414
2002 6 55.618 2.876 0.3310 0.6667 0.6690
2003 7 50.062 2.501 0.1812 0.7778 0.8188
2004 8 45.055 1.972 0.0573 0.8889 0.9427

MAXIMO =
CRITICO =
AREAS DE INFLUENCIA GUMBEL
B (Km2) C (Km2) D (Km2) AREA CUENCA Pmed. (mm)
31.52 70.51 57.16 329.55 127.260 AÑO
31.52 70.51 57.16 329.55 85.462 1997
31.52 70.51 57.16 329.55 75.168 1998
31.52 70.51 57.16 329.55 65.459 1999
31.52 70.51 57.16 329.55 60.989 2000
31.52 70.51 57.16 329.55 55.618 2001
31.52 70.51 57.16 329.55 50.062 2002
31.52 70.51 57.16 329.55 45.055 2003
2004

LN2
0.0842
0.0107
0.0326
0.0851
0.0574
0.0472
0.0333
0.0041

0.0851
0.4808
ACEPTADA
LN3 MEDIA 3.223
0.0565 DESV.EST. 0.793
0.0123 a 37.869895
0.0245
0.0082 C.ASIMETRIA 2.179440245E-06
0.0142
0.0024
0.0410
0.0538

0.0565
0.4808
ACEPTADA
Nº DATOS Pmed. (mm) y = (x - u)/a Tr EMPIRICA GUMBEL GUMBEL
1 127.260 2.4254 11.81 0.1111 0.0846 0.0265
2 85.462 0.9925 3.23 0.2222 0.3097 0.0875
3 75.168 0.6396 2.44 0.3333 0.4099 0.0766
4 65.459 0.3068 1.92 0.4444 0.5209 0.0764
5 60.989 0.1535 1.74 0.5556 0.5758 0.0203
6 55.618 -0.0306 1.55 0.6667 0.6434 0.0233
7 50.062 -0.2210 1.40 0.7778 0.7127 0.0650
8 45.055 -0.3927 1.29 0.8889 0.7726 0.1163

MEDIA = 70.634 MAXIMO = 0.1163


DESV. EST. = 26.375 CRITICO = 0.4808
ACEPTADA
n = nº de dato 8
yn medio = 0.4843
Sn = 0.9043

parámetros, según n
a = Sx / Sn = 29.17
u = x-yn*a= 56.51
CURVAS IDF:

id=i24 (24/d)^0.5 Formula de GRUNSKY


Donde:
id: Intensidad de lluvia sin considerar el tiempo de retorno
i24 : Intensidad de lluvia sin considerar el tiempo de retorno
d : duración del aguacero en horas.

Para ajustar la intensidad de lluvia involucrando el periodo de retorno se ha empleado el metodo de Gumbel

Intensidad Historica (mm/hr)


Año Pmáx. (24hl) I24 Duración de Lluvia, en minutos
(mm) (mm/h) 15 30 60
1997 127.260 5.30 51.95 36.74 25.98
1998 85.462 3.56 34.89 24.67 17.44
1999 75.168 3.13 30.69 21.70 15.34
2000 65.459 2.73 26.72 18.90 13.36
2001 60.989 2.54 24.90 17.61 12.45
2002 55.618 2.32 22.71 16.06 11.35
2003 50.062 2.09 20.44 14.45 10.22
2004 45.055 1.88 18.39 13.01 9.20

Promedio 23.07 16.31 11.53


Desv. Stand. 10.77 7.61 5.38
n° datos 8 8 8
yn 0.4843 0.4843 0.4843
Sn 0.9043 0.9043 0.9043
a 11.907 8.420 5.954
u 17.302 12.235 8.651

Tr Duración de la lluvia en minutos


años 15 30 60
5 35.16 24.86 17.58
25 55.39 39.17 27.69
50 63.76 45.09 31.88
75 68.63 48.53 34.32
100 72.08 50.97 36.04
CURVAS IDF
80.00

70.00

Intensidades
60.00

50.00

40.00

30.00

20.00

10.00

0.00
15 30 60 120 180
empleado el metodo de Gumbel

d Historica (mm/hr)
e Lluvia, en minutos
120 180
18.37 15.00
12.34 10.07
10.85 8.86
9.45 7.71
8.80 7.19
8.03 6.55
7.23 5.90
6.50 5.31

8.16 6.66
3.81 3.11
8 8
0.4843 0.4843
0.9043 0.9043
4.210 3.437
6.117 4.995

e la lluvia en minutos
120 180
12.4317992 10.1505215
19.5826053 15.9891302
22.5438236 18.4069549
24.2649965 19.8122867
25.4831767 20.8069266
URVAS IDF

Tr 5
Tr 25
Tr 50
Tr 75
Tr
100

120 180
Hallamos el Tiempo de concentración:

Tc = 0.0195(L3/H)0.385

Pto inicio: 1430.00


Pto final: 350.00

H= 1080.00
L= 22237.71

Tc = 139.01

Tc = 0.0003245(L/S^0.5)^0.77

L= 22237.71 m.
S= 0.05
Tc = 0.0003245(L/S^0.5)^0.77
Tc = 138.80 min.

Tomamos Tc = 170,83 min por ser el punto hidraulicamente mas lejano.

CURVAS IDF
80.00
Intensidades

70.00

60.00

50.00

40.00

30.00

19.00
20.00

10.00

0.00
15 30 60 120
20.00

10.00

0.00
15 30 60 120

Para un diseño de un puente:


Tr = 50 años
Tc = 170,83 min
Imax. = 0,625 mm/min.

CALCULO DE CAUDAL DE DISEÑO:

Q = CIA/360

A= 329.55 km2
I= 19 mm/h
C= 0.15 (considerando un suelo cesped arenoso mediano con

Q= 260.89
hidraulicamente mas lejano.

URVAS IDF
139.00

60 120 180
60 139.00 120 180

n suelo cesped arenoso mediano con pendiente de 4%)

You might also like