PO WE R SEM IC O ND UC TO R S
P6KE SERIES
600W TRANSIENT VOLTAGE SUPPRESSORS
Features
! Glass Passivated Die Construction
! 600W Peak Pulse Power Dissipation
! 6.8V – 440V Standoff Voltage A B A
! Uni- and Bi-Directional Versions Available
! Excellent Clamping Capability
! Fast Response Time
! Plastic Case Material has UL Flammability
Classification Rating 94V-O C
D
Peak Pulse Power Dissipation at TA = 25°C (Note 1, 2, 5) Figure 3 PPPM 600 Minimum W
Peak Pulse Current on 10/1000µS Waveform (Note 1) Figure 1 IPPM See Table 1 A
Note: 1. Non-repetitive current pulse, per Figure 1 and derated above TA = 25°C per Figure 4.
2. Mounted on 40mm2 copper pad.
3. 8.3ms single half sine-wave duty cycle = 4 pulses per minutes maximum.
4. Lead temperature at 75°C = TL .
5. Peak pulse power waveform is 10/1000µS.
tr = 10ms
100 Peak Value Ipp Measured at
1000
Measured at
50 Stand-off Voltage
100
tp
10 X 1000 Waveform
as defined by R.E.A. 10
0 1 10 100 1000
0 1 2 3
VRWM, REVERSE STANDOFF VOLTAGE (V)
t, TIME (ms)
Fig. 1 Pulse Waveform Fig. 2 Typical Junction Capacitance
100
PP, PEAK PULSE POWER (kW)
IMPULSE
10
1.0
TC = 25°C
0.1
0.1 1.0 10 100 1000 10000
100 5.0
Pd , STEADY STATE POWER DISSIPATION (W)
Single Phase
Half-Wave 60Hz
Resistive or
Inductive Load
75 3.75
50 2.5
L = 9.5 mm
25
1.25
10 X 1000 Waveform
as defined by REA 40 x 40 x 1 mm Cu
0
0
0 25 50 75 100 125 150 175 200
0 25 50 75 100 125 150 175 200
TA, AMBIENT TEMPERATURE (°C) TL , LEAD TEMPERATURE (°C)
Fig. 4 Pulse Derating Curve Fig. 5, Steady State Power Derating
Won-Top Electronics Co., Ltd (WTE) has checked all information carefully and believes it to be correct and accurate. However, WTE cannot assume any
responsibility for inaccuracies. Furthermore, this information does not give the purchaser of semiconductor devices any license under patent rights to
manufacturer. WTE reserves the right to change any or all information herein without further notice.
WARNING: DO NOT USE IN LIFE SUPPORT EQUIPMENT. WTE power semiconductor products are not authorized for use as critical components in life
support devices or systems without the express written approval.