BILL NO.

2
HVAC WORKS

Item Description Qty Unit Unit Amount


Rate US.$

MINI-SPLIT UNIT

Mini-Split Units Including Evaporator Blower Unit and Condensing Unit with Steel base,
vibration isolators, refrigerant pipes, condensate pipes, controls and accessories:

A Concealed Split unit, cooling capacity 1 Ton complete with 66 No.


refrigerant pipes.
B Concealed Split unit, cooling capacity 1.5 Ton complete 0 No.
with refrigerant pipes.
C Concealed Split unit, cooling capacity 2 Ton complete with 0 No.
refrigerant pipes.
D Concealed Split unit, cooling capacity 3 Ton complete 66 No.
with refrigerant pipes.

Supply, Install and Test the Following Fans, Including Flanges, Support Framing, Mounting
Bolts, Controls and all Necessary Fixing Accessories and Connection as Specified and as
Shown on Drawings:
Supply, Install and Test the Following Fans, Including Flanges, Support Framing, Mounting
Bolts, Controls and all Necessary Fixing Accessories and Connection as Specified and as
Shown on Drawings:

E Wall Type Exhaust Fan with fire rated shutter (100 CFM). 77 No.

Fresh Air Fan


Supply, Install and Test the Following Fans, Including Flanges, Support Framing, Mounting
Bolts, Controls and all Necessary Fixing Accessories and Connection as Specified and
prezarization for fire rated for 2 hours at 250 C with sensor and mtorized connection with all
contractor should submit static pressor construction for consultant reviw and approvel.

F FAF (Pump fresh air fan), 500 CFM


G FAF (Pump fresh air fan), 680 CFM 1 No.
H FAF (Pump fresh air fan),1055 CFM 1 No.
1 No.
Pressurization Fan
Supply, Install and Test the Following Fans, Including Flanges, Support Framing, Mounting
Bolts, Controls and all Necessary Fixing Accessories and Connection as Specified and
prezarization for fire rated for 2 hours at 250 C with sensor and mtorized connection with all
contractor should submit static pressor construction for consultant reviw and approvel.

I PF 200 CFM 1 No.


J PF 300 CFM 1 No.
K PF 760 CFM 1 No.
L PF 1055 CFM 1 No.
M PF 575 CFM 1 No.

Sypply and install the following below as per drawing and specification and as per QCDD regulation

EXHAUST GRILLE (basement level) Fire rated as per 1 LS


qcdd regulation and as per drawing and specification.
SUPPLY GRILLE (basement level) Fire rated as per qcdd 1 LS
regulation and as per drawing and specification.

DOOR LOUVER Fire rated as per qcdd regulation and as 1 LS


per drawing and specification.

AXIAL FAN (basement level) Fire rated as per qcdd 1 LS


regulation and as per drawing and specification.

FIRE DAMPER (located in wall) Fire rated as per qcdd 11 No


regulation and as per drawing and specification.

VOLUME DAMPER Fire rated as per qcdd regulation and 22 No


as per drawing and specification.

AXIAL FAN (pantry/toilet) Fire rated as per qcdd 77 No


regulation and as per drawing and specification.

EXHAUST CEILING DIFFUSER Fire rated as per qcdd 1 LS


regulation and as per drawing and specification.

DISK VALVE EXHAUST DIFFUSER Fire rated as per 1 LS


qcdd regulation and as per drawing and specification.

MOTORIZED DAMPER Fire rated as per qcdd regulation 24 No


and as per drawing and specification.

DUCT SIZE 150X100 Fire rated as per qcdd regulation 206 m


and as per drawing and specification.

DUCT SIZE 150X150 Fire rated as per qcdd regulation 7m


and as per drawing and specification.

DUCT SIZE 150X200 Fire rated as per qcdd regulation 31 m


and as per drawing and specification.
DUCT SIZE 200x200 Fire rated as per qcdd regulation 42 m
and as per drawing and specification.

DUCT SIZE 250x200 Fire rated as per qcdd regulation 104 m


and as per drawing and specification.

DUCT SIZE 300x250 Fire rated as per qcdd regulation 42 m


and as per drawing and specification.
Supply, Install and Test the Following Fans, Including Flanges, Support Framing, Mounting
Bolts, Controls and all Necessary Fixing Accessories and Connection as Specified and
prezarization for fire rated for 2 hours at 250 C with sensor and mtorized connection with all
contractor should submit static pressor construction for consultant reviw and approvel.

I Wall Type Exhaust Fan with fire rated shutter (100 CFM). 143 No.

Fresh Air Fan

A FAF (Pump fresh air fan), 500 CFM


B FAF (Pump fresh air fan), 680 CFM 1 No.
C FAF (Pump fresh air fan),1055 CFM 1 No.
1 No.
Pressurization Fan

D PF 200 CFM
E PF 300 CFM 1 No.
F PF 760 CFM 2 No.
G PF 1055 CFM 1 No.
H PF 575 CFM 2 No.
3 No.