VIESMANN VITOCAL 200-S

Air/water heat pump, split version


3.0 to 10.6 kW

Datasheet
For part no. and prices: see pricelist

VITOCAL 200-S Type AWB 201.B VITOCAL 200-S Type AWB-AC 201.B

Heat pump with electric drive in split design with external and Equipment level as per type AWB 201.B, with additional active
internal unit. cooling function plus integral instantaneous heating water
For central heating and DHW heating in heating systems. heater.

5822 525 GB 5/2011


Benefits

■ Low operating costs through high COP (COP = Coefficient of Per- ■ Easy to use Vitotronic control unit with plain text and graphic display
formance) to EN 14511: Up to 4.6 (air 7 °C/water 35 °C) and up to ■ Highly convenient through reversible system that enables heating
3.5 (air 2 °C/water 35 °C). Output control and DC inverter for high and cooling.
efficiency in partial load operation.
■ Maximum flow temperature: Up to 55 °C at -15 °C outside temper-
ature (with reduced output). EHPA quality seal as proof of the COP for subsidy according
■ Weather-proof external unit with evaporator, compressor, expansion to the German market incentive programme.
valve and fan.
■ Internal unit with high efficiency heating circuit pump (to Energy
Label A), heat exchanger, 3-way diverter valve, safety assembly and
control unit; for the heating/cooling versions with an integral instan-
taneous heating water heater.

5822 525 GB

2 VIESMANN VITOCAL 200-S


Specification

Specification
Vitocal 200-S
Type AWB/AWB-AC 201.B04 201.B07 201.B10 201.B13
Output details, heating
to EN 14511 (A2/W35 °C, 5 K spread)
Rated heating output kW 3.00 5.60 7.70 10.60
Compressor frequency Hz 60 65 55 75
Fan speed rpm 870 650 650 650
Power consumption kW 0.91 1.73 2.20 3.25
Coefficient of performance ε (COP) in 3.27 3.24 3.50 3.26
heating mode
Output control kW 1.10 – 3.80 1.30 – 7.70 4.40 – 9.90 5.00 – 11.90
Heating output data
to EN 14511 (A7/W35 °C, 5 K spread)
Rated heating output kW 4.50 8.00 10.90 14.60
Compressor frequency Hz 60 65 55 75
Fan speed rpm 870 650 650 650
Power consumption kW 0.97 1.88 2.36 3.40
Coefficient of performance ε (COP) in 4.64 4.26 4.62 4.29
heating mode
Cooling capacity data
to EN 14511 (A35/W7 °C, 5 K spread)
Rated cooling capacity kW 3.20 6.20 7.40 9.10
Compressor frequency Hz 60 65 55 70
Fan speed rpm 870 650 650 650
Power consumption kW 1.08 2.40 2.69 3.64
Energy efficiency ratio EER 2.96 2.60 2.75 2.50
Output control kW 1.2 – 3.8 1.6 – 8.0 2.4 – 8.5 2.4 – 10.0
Cooling capacity data
to EN 14511 (A35/W18 °C, 5 K spread)
Rated cooling capacity kW 4.20 8.80 10.00 12.60
Compressor frequency Hz 60 65 55 70
Fan speed rpm 870 650 650 650
Power consumption kW 1.13 2.63 2.80 4.20
Energy efficiency ratio EER 3.72 3.35 3.57 3.00
Air intake temperature
Cooling mode (type AWB-AC)
– Min. °C 15 15 15 15
– Max. °C 45 45 45 45
Heating mode (type AWB, AWB-AC)
– Min. °C –15 –15 –15 –15
– Max. °C 35 35 35 35
Heating water
at 10 K spread
Content l 2.2 2.2 3.2 3.2
Minimum flow rate (always maintain) l/h 600 820 1200 1380
Max. flow temperature °C 55 55 55 55
Electrical values
External unit
– Rated voltage, compressor 1/N/PE 230 V/50 Hz
– Max. rated current, compressor A 5 9 10 15
– Starting current, compressor A 10.5 15 10 10
– Compressor starting current with stalled A 20 25 25 32
armature
– Starting current (charging DC capaci- A 45 < 35 30 30
tors)
– Internal fuse/MCB A 3.5 3.5 3.15 3.15
– IP rating IP 24 24 24 24
5822 525 GB

VITOCAL 200-S VIESMANN 3


Specification (cont.)

Type AWB/AWB-AC 201.B04 201.B07 201.B10 201.B13


Electrical values
Internal unit
Heat pump control unit/PCB
– Rated voltage, control unit/PCB 1/N/PE 230 V/50 Hz
– Fuse protection, power supply 1xB16A
– Internal fuse/MCB 6.3A (slow)/250 V
Instantaneous heating water heater
Only for type AWB-AC
– Rated voltage 1/N/PE 230 V/50 Hz
3/N/PE 400 V/50 Hz
– Heating output kW 8.8 8.8 8.8 8.8
– Fuse protection, power supply 3xB16A 3xB16A 3xB16A 3xB16A
Electrical power consumption
– Fan (max.) W 65 70 130 130
– External unit (max.) W 3.0 3.6 5.8 5.8
– Secondary pump W 50 50 70 70
– Control unit/PCB, external unit (max.) W 150 150 150 150
– Control unit/PCB, internal unit (max.) W 5 5 5 5
– Max. power, control unit/PCB W 1000 1000 1000 1000
Refrigerant circuit
Refrigerant R410A R410A R410A R410A
Fill volume kg 1.2 2.15 2.95 2.95
Top-up amount for line lengths >12 m to g/m 20 60 60 60
≤30 m
Compressor (hermetically sealed) Type Rotating piston Rotating piston Scroll Scroll
Permiss. operating pressure
– High pressure side bar 43 43 43 43
MPa 4.3 4.3 4.3 4.3
– Low pressure side bar 43 43 43 43
MPa 4.3 4.3 4.3 4.3
Dimensions
External unit
Total length mm 869 1040 900 900
Total width mm 290 340 340 340
Total height mm 610 865 1255 1255
Internal unit

Total length mm 450 450 450 450


Total width mm 360 360 360 360
Total height mm 905 905 905 905
Total weight
External unit kg 43 66 110 110
Internal unit type AWB kg 34 34 37 37
Internal unit type AWB-AC kg 38 38 41.5 41.5
Permiss. operating pressure, secondary bar 3 3 3 3
side MPa 0.3 0.3 0.3 0.3
Connections
Heating water flow G 1¼ 1¼ 1¼ 1¼
Heating water return and DHW cylinder G 1¼ 1¼ 1¼ 1¼
return
DHW cylinder flow G 1¼ 1¼ 1¼ 1¼
Condensate line (external unit) mm 16 x 1 16 x 1 16 x 1 16 x 1
Liquid line
– Pipe 7 mm 6x1 10 x 1 10 x 1 10 x 1
– Internal unit UNF ⅝ ⅝ ⅝ ⅝
– External unit UNF ⁷⁄₁₆ ⅝ ⅝ ⅝
Hot gas line
– Pipe 7 mm 12 x 1 16 x 1 16 x 1 16 x 1
– Internal unit UNF ⅞ ⅞ ⅞ ⅞
– External unit UNF ¾ ⅞ ⅞ ⅞
Refrigerant line lengths
– Min. m 3 3 3 3
– Max. m 20 30 30 30
Sound power of the external unit*1
Weighted total sound power level at
5822 525 GB

A7 °C (±3 K)/W35 °C (±5 K)


– At rated heating output dB(A) 60 62 62 63

*1 Measurements with reference to EN 12102/EN ISO 9614-2

4 VIESMANN VITOCAL 200-S


Specification (cont.)

Internal unit dimensions

A B 450 /
AB

150
360 360

960
905
50
40

58

41
+
75
1105

147
219
294
369

A Cable entry <42 V


B Cable entry 400 V~/230 V~, >42 V
5822 525 GB

VITOCAL 200-S VIESMANN 5


Specification (cont.)

A B

100 100

1000

A Cable entry <42 V


B Cable entry 400 V~/230 V~, >42 V

Hydraulic connections
Symbol Meaning Connection
Refrigerant lines from/to the external unit: 7 connection pipe UNF thread
– Liquid line 10 mm ⅝
For type AWB-AC 201.B04, a reduction from 10 to 6 mm is required
downstream from the internal unit connection (reducer ⅝ to ⁷⁄₁₆
supplied).
– Hot gas line 16 mm ⅞
For type AWB-AC 201.B04, a reduction from 16 to 12 mm is
required downstream from the internal unit connection (reducer ⅞
to ¾ supplied).
DHW cylinder flow (heating water side) G 1¼

Heating water return and DHW cylinder return G 1¼


+
Heating water flow G 1¼

5822 525 GB

6 VIESMANN VITOCAL 200-S


Specification (cont.)

External unit dimensions


Type AWB/AWB-AC 201.B04

869
290 610 795

74
500

40

308
5822 525 GB

VITOCAL 200-S VIESMANN 7


Specification (cont.)

Type AWB/AWB-AC 201.B07

1040
340 950

865

527 90

48

378
5822 525 GB

8 VIESMANN VITOCAL 200-S


Specification (cont.)

Types AWB/AWB-AC 201.B10 and B13

340 903

1255

357 705 97
50
357
5822 525 GB

VITOCAL 200-S VIESMANN 9


Printed on environmentally friendly,
chlorine-free bleached paper

Subject to technical modifications.

Viessmann Werke GmbH&Co KG Viessmann Limited


D-35107 Allendorf Hortonwood 30, Telford
5822 525 GB

Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB


Fax: +49 6452 70-2780 Telephone: +44 1952 675000
www.viessmann.com Fax: +44 1952 675040
E-mail: info-uk@viessmann.com

10 VIESMANN VITOCAL 200-S