22 Series Exit Devices

22 Exit Device

Finishes
Color US Number BHMA Number

Sprayed Aluminum SP28 689

Sprayed Dark Bronze SP313 695

© 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.
22 Exit Device
Index
Introduction...............................................................................................................................................................1
Panic Exit Hardware • Rim Devices
• 22 Rim Device ................................................................................................................................................2
• 22 Rim Device Trim........................................................................................................................................3
• Surface Mounted Vertical Rod Devices
• 2227 Surface Mounted Vertical Rod Device..................................................................................................6
• 2227 Surface Mounted Vertical Rod Device Trim..........................................................................................7
Fire Exit Hardware • Fire Exit Rim Devices
• 22-F Fire Exit Rim Device...............................................................................................................................4
• 22-F Fire Exit Rim Device Trim.......................................................................................................................5
• Fire Exit Surface Mounted Vertical Rod Devices
• 2227-F Fire Exit Surface Mounted Vertical Rod Device.................................................................................8
• 2227-F Fire Exit Surface Mounted Vertical Rod Device Trim ........................................................................9
Trim Selection • Optional Trim ........................................................................................................................................................10
• Lever Designs.......................................................................................................................................................10
• Operation Options.................................................................................................................................................10
Strike Selection • Strikes...................................................................................................................................................................12
• Strikes/Stiles.........................................................................................................................................................12
Device Electrical • ALK – Exit Alarm kit .............................................................................................................................................15
• LX – Latch Bolt Monitoring ..................................................................................................................................16
• RX – Request to Exit ............................................................................................................................................16
• RX2 – Double Request to Exit..............................................................................................................................16
Device Accessories • Cover Plate Kit ......................................................................................................................................................14
• Cylinders...............................................................................................................................................................11
• EPT – Electrical Power Transfer ...........................................................................................................................15
• GBK – Glass Bead Kit ...........................................................................................................................................14
• PS9 – Alarm Kit Power Supply ............................................................................................................................15
• Rod and Latch Guards .........................................................................................................................................14
Device Options • LBR – Less Bottom Rod ......................................................................................................................................14
• LD – Less Dogging...............................................................................................................................................14
• PL – Pullman Latch ..............................................................................................................................................14
Additional Information • ANSI Grade, Type & Function ..............................................................................................................................13
• Device, Latch and Rod Dimensions .....................................................................................................................13
• UL Fire Labeling and Opening Sizes ....................................................................................................................13
• Finishes.................................................................................................................................................Inside Cover
• Handing ................................................................................................................................................................13
• How-to-Order Information....................................................................................................................................18
• Popular Double Door Applications.......................................................................................................................17
• Nomenclature .......................................................................................................................................................18
Symbols
Indicates Fire Rated Application Indicates ADA Products

Introduction
Exit devices are a critical part of the Fire and Life Safety egress system and will provide safe and reliable service when properly
applied and maintained. Von Duprin designs and manufactures exit devices in accordance to ISO 9001 Quality Management
System and meets or exceed accepted U.S. domestic and International standards. All 22 series exit devices are UL listed for
Panic Hardware or Fire Hardware, and are certified to ANSI A156.3, 2001, Grade1. Consult your local IR Security & Safety
consultant or the Von Duprin factory for current listings.

It is intended that the information included in this publication, when properly used, will provide clear and reliable guidelines to
the proper general selection and application. However, the scope of the information is necessarily limited.

Unusual operating conditions and environments and other external influences can affect the proper application of the products
represented. Modifications of these products will also affect UL listings. It is recommended that whenever an unusual application
condition exists, or when any modification of a product is considered, that our engineers review the application.

Application engineering services are available to help ensure proper selection or to review any areas where users of Von Duprin
products may have questions.
© 2005 Ingersoll-Rand Co. May be copied for use with specification submittal. 1
22 Rim Exit Device

22 rim exit device for all types of single and double doors with mullion, UL listed for Panic Exit
Hardware. Devices are ANSI A156.3, 2001, Grade 1. Covers stock hollow metal doors with 161*
cutouts. Fits door stiles as narrow as 3 ¹³|₁₆" (97mm), see page 12. See opposite page for available
outside trim and device functions.
*Not applicable with all strike and mullion combinations, consult factory.
Specifications
299 Strike
Device Functions Ships ready for all functions; EO, DT, NL, TP, K, L
Device Handing Non-Handed
Device Lengths 3’ (914mm) – see minimum door opening chart at bottom of page
4’ (1219mm) – see minimum door opening chart at bottom of page
Finishes SP28, SP313
Strikes 299 Dull Black
Optional Strikes see page 12
Dogging Feature Hex key dogging standard
LD Less Dogging see page 14
Electric Options LX Latchbolt Monitor Switch see page 14
RX Touch Bar Monitor Switch see page 14
RX2 Double Touch Bar Monitor Switch see page 14
ALK Alarm Exit Kit see page 14
Miscellaneous Options GBK Glass Bead Kit see page 15
Fasteners & Includes 1 ³|₄" (19mm) – 2 ¹|₄" (57mm) Wood & Metal Doors
Sex Bolts (SNB) Optional SNB available for device, see next page for quantities
Latch Bolt Deadlocking, ³|₄" (19mm) throw
Device Centerline from 39 ¹³|₁₆" (1011mm) at center of device
Finished Floor 39 ¹¹|₁₆" (1008mm) with Mullion
Device Dimensions see page 13
See page 16 for How to Order specification
Minimum Door Opening Chart

Stop Single Double Door Minimum Door Opening Minimum Door Opening
Height Strike Door w/Mullion for 3´ device* w/ALK*
¹|₂´´ 299 Yes –– 26.500´´ (673mm) 33.250´´(845mm)
¹|₂´´ 1439 Yes –– 25.687´´ (652mm) 32.437´´(824mm)
¹|₂´´ 299 –– 4754/4854/4954 27.000´´ (686mm) 33.750´´(857mm)
¹|₂´´ 299 –– 5654 25.812´´ (656mm) 32.562´´(827mm)
¹|₂´´ 1408 –– 5754 25.750´´ (679mm) 32.500´´(826mm)
¹|₂´´ 1606 –– 1654 26.562´´ (675mm) 33.312´´(846mm)
⁵|₈´´ 299 Yes –– 26.750´´ (679mm) 33.500´´(851mm)
⁵|₈´´ 1439 Yes –– 25.937´´ (659mm) 32.687´´(830mm)
⁵|₈´´ 299 –– 4754/4854/4954 27.125´´ (689mm) 33.875´´(860mm)
⁵|₈´´ 299 –– 5654 26.687´´ (678mm) 33.437´´(849mm)
⁵|₈´´ 1408 –– 5754 25.875´´ (657mm) 32.625´´(829mm)
⁵|₈´´ 1606 –– 1654 26.687´´ (678mm) 33.437´´(849mm)
*For 4´ device, add 6´´ (152mm)

2 © 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.
22 Rim Exit Device Standard Trim
Exit only Dummy Trim Night Latch Night Latch
Pull when Dogged Key Retracts Latchbolt Key Retracts Latchbolt
Optional Pull Required

Product Description 22EO 22DT 22NL 22NL-OP

–– 210DT* 210NL* 110NL-MD*


Trim Description
110NL-WD*
5³|₈" x 4²⁵|₃₂" x ³|₃₂" 5³|₈" x 4²⁵|₃₂" x ³|₃₂"
Escutcheon Plate Size –– ––
(137x121x2mm) (137x121x2mm)

Pull Center to Center –– –– –– ––

Projection –– 1³¹|₃₂" (42mm) 1³¹|₃₂" (42mm) ––

ANSI Function 01 02 03 03

Cylinder Type –– –– Rim Rim


Optional Trim
(See page 10) 230EO 230DT 230NL ––

Optional #425 Sex Bolt 6 (with no trim)


Quantity for Device 2 (with EO trim) 2 2 6

* ANSI/BHMA A156.3 (2001) Grade 1 Trim

Thumbpiece Knob Lever


Key Locks & Unlocks Key Locks & Unlocks Key Locks & Unlocks

Product Description 22TP 22K 22L

Trim Description 230TP* 210K 230L*

3" x 12¹|₁₆" x ³|₃₂" 3" x 4²⁵|₃₂" x ³|₃₂" 3" x 6³|₈" x ¹⁵|₁₆"


Escutcheon Plate Size
(76x306x2mm) (76x121x2mm) (76x162x24mm)

Pull Center to Center 5¹|₂" (140mm) –– ––

Projection 2" (51mm) 2¹⁵|₁₆" (75mm) 2⁵|₈" (67mm)

ANSI Function 05 08 08

Cylinder Type 1¹|₄" Mortise Furnished 1¹|₄" Mortise

Optional Trim
(See page 10) 230TP-BE 210K-BE 230L-BE

Optional #425 Sex Bolt


Quantity for Device
2 2 2 3

* ANSI/BHMA A156.3 (2001) Grade 1 Trim


22-F Rim Fire Exit Device

22-F rim fire exit device for all types of single doors up to 4’ x 8’ (1219mm x 3048mm) or
8’ x 8’ (2438mm x 3048mm) double doors with 9954 or 9854 mullion, UL listed for Fire Exit Hardware.
See page 13 for detailed information on UL listed fire exit hardware label and door opening size
information. Devices are ANSI A156.3, 2001, Grade 1. Fits door stiles as narrow as 4 ³|₈" (111mm), see
page 12. See opposite page for available outside trim and device functions.

Specifications
299F Strike
Device Functions Ships ready for all functions; EO, NL, TP, K, L
Device Handing Non-Handed
Device Lengths 3’ (914mm) – see minimum door opening chart at bottom of page
4’ (1219mm) – see minimum door opening chart at bottom of page
Finishes SP28, SP313
Strikes 299F – Dull Black, single doors
499F – Dull Black, double door with 9954 or 9854 mullion
499F Strike Optional Strike see page 12
With 9854/9954 Dogging Feature No mechanical dogging
Mullion Electric Options LX Latchbolt Monitor Switch see page 14
RX Touch Bar Monitor Switch see page 14
RX2 Double Touch Bar Monitor Switch see page 14
ALK Alarm Exit Kit see page 14
Miscellaneous Options GBK Glass Bead Kit see page 15
Fasteners & Includes 1 ³|₄" (19mm) – 2 ¹|₄" (57mm) Wood & Metal Doors
Sex Bolts (SNB) Optional SNB available for device, see next page for quantities.
Sex bolts are required on wood fire doors.
Latch Bolt Deadlocking, ³|₄" (19mm) throw
Device Centerline from 39 ¹³|₁₆" (1011mm) at center of device
Finished Floor 39 ¹¹|₁₆" (1008mm) with Mullion
Device Dimensions see page 13

See page 16 for How to Order specification

Minimum Door Opening Chart

Stop Single Double Door Minimum Door Opening Minimum Door Opening
Height Strike Door w/Mullion for 3´ device* w/ALK*
¹|₂´´ 299F/499F Yes –– 26.500´´ (673mm) 33.250´´(845mm)
¹|₂´´ 299F/499F –– KR/9854/9954 27.000´´ (686mm) 33.750´´(857mm)
⁵|₈´´ 299F/499F Yes –– 26.750´´ (679mm) 33.500´´(851mm)
⁵|₈´´ 299F/499F –– KR/9854/9954 27.125´´ (689mm) 33.875´´(860mm)

*For 4´ device, add 6´´ (152mm)

4 © 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.
22-F Rim Fire Exit Device Standard Trim
Exit only Night Latch Night Latch
Key Retracts Latchbolt Key Retracts Latchbolt
Optional Pull Required

Product Description 22EO-F 22NL-F 22NL-OP-F

Trim Description –– 210NL** 110NL-MD**


110NL-WD**
5³|₈" x 4²⁵|₃₂" x ³|₃₂"
Escutcheon Plate Size –– ––
(137x121x2mm)
Pull Center to Center –– –– ––
Projection –– 1³¹|₃₂" (42mm) ––

ANSI Function 01 03 03

Cylinder Type –– Rim Rim


Optional Trim
(See page 10) 230EO 230NL ––

*Optional #425 Sex Bolt 6 (with no trim) 2 6


Quantity for Device 2 (with EO trim)
*Additional 425 SNB for 2 2 2
499F strike
* Sex Bolts are required for wood fire doors
** ANSI/BHMA A156.3 (2001) Grade 1 Trim

Thumbpiece Knob Lever


Key Locks & Unlocks Key Locks & Unlocks Key Locks & Unlocks

Product Description 22TP-F 22K-F 22L-F

Trim Description 230TP** 210K 230L**

3" x 12¹|₁₆" x ³|₃₂" 3" x 4²⁵|₃₂" x ³|₃₂" 3" x 6³|₈" x ¹⁵|₁₆"


Escutcheon Plate Size
(76x306x2mm) (76x121x2mm) (76x162x24mm)

Pull Center to Center 5¹|₂" (140mm) –– ––

Projection 2" (51mm) 2¹⁵|₁₆" (75mm) 2⁵|₈" (67mm)

ANSI Function 05 08 08

Cylinder Type 1¹|₄" Mortise Furnished 1¹|₄" Mortise

Optional Trim
(See page 10) 230TP-BE 210K-BE 230L-BE

*Optional #425 Sex Bolt 2 2 2


Quantity for Device
*Additional 425 SNB for 2 2 2
499F strike
5
* Sex Bolts are required for wood fire doors
** ANSI/BHMA A156.3 (2001) Grade 1 Trim
2227 Surface Mounted Vertical Rod Device

2227 surface mounted vertical rod exit device for all types of single and double doors, UL listed for
Panic Exit Hardware. Devices are ANSI A156.3, 2001, Grade 1. Covers stock hollow metal doors with
86 or 161 cutouts. Fits door stiles as narrow as 3 ⁵|₈" (92mm), see page 12. See opposite page for
available outside trim and device functions.
Top Latch
Specifications
Device Functions Ships ready for all functions; EO, DT, NL, TP, K, L
Device Handing Non-Handed
Device Lengths 3’ (914mm) – see minimum door opening chart at bottom of page
4’ (1219mm) – see minimum door opening chart at bottom of page
299 Top Strike
Door Height 7’ (2134mm) – standard door height
Extension rods available for door heights up to 10’
12" (205mm)
36" (914mm)
Finishes SP28, SP313
Strikes Top 299 – Dull Black
Bottom 248L-4 and 304L – Unfinished
Optional Strikes see page 12
248L4
Bottom Strike Dogging Feature Hex key dogging standard
for use with LD Less Dogging see page 14
flat threshold Electric Options LX Latchbolt Monitor Switch see page 14
RX Touch Bar Monitor Switch see page 14
RX2 Double Touch Bar Monitor Switch see page 14
ALK Alarm Exit Kit see page 14
Miscellaneous Options PL Pullman Latch see page 14
GBK Glass Bead Kit see page 15
RG Rod Guards see page 15
304L
LG Latch Guards see page 15
Bottom Strike
Fasteners & Includes 1 ³|₄" (19mm) – 2 ¹|₄" (57mm) Wood & Metal Doors
Sex Bolts (SNB) Optional SNB available for device, see next page for quantities.
Sex Bolts are furnished standard for top and bottom latches.
Latch Bolt Deadlocking Anti-friction Top and Bottom Bolt, ⁵|₈" (16mm) throw
Device Centerline from 39 ¹³|₁₆" (1011mm)
Bottom Latch
Finished Floor
Door Undercut ¹|₄" (7mm) from finished floor recommended, ³|₄" (19mm)
maximum or ¹|₈" (3mm) from threshold
Device Dimensions see page 13
See page 16 for How to Order specification

Minimum Door Opening Chart

Stop Single Double Door Minimum Door Opening Minimum Door Opening
Height Strike Door w/Mullion for 3´ device* w/ALK*
¹|₂´´ N/A Yes Vert. x Vert. 25.875´´ (657mm) 32.625´´(829mm)
⁵|₈´´ N/A Yes Vert. x Vert. 26.000´´ (664mm) 32.750´´(832mm)

*For 4´ device, add 6´´ (152mm)

6 © 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.
2227 Surface Mounted Vertical Rod Device Trim
Exit only Dummy Trim Night Latch Night Latch
Pull when Dogged Key Retracts Latchbolt Key Retracts Latchbolt
Optional Pull Required

Product Description 2227EO 2227DT 2227NL 2227NL-OP

–– 210DT* 210NL* 110NL-MD*


Trim Description
110NL-WD*
5³|₈" x 4²⁵|₃₂" x ³|₃₂" 5³|₈" x 4²⁵|₃₂" x ³|₃₂"
Escutcheon Plate Size –– ––
(137x121x2mm) (137x121x2mm)

Pull Center to Center –– –– –– ––

Projection –– 1³¹|₃₂" (42mm) 1³¹|₃₂" (42mm) ––

ANSI Function 01 02 03 03

Cylinder Type –– –– Rim Rim


Optional Trim
(See page 10) 230EO 230DT 230NL ––

Optional #425 Sex Bolt 6 (with no trim)


Quantity for Device 2 (with EO trim) 2 2 6

* ANSI/BHMA A156.3 (2001) Grade 1 Trim

Thumbpiece Knob Lever


Key Locks & Unlocks Key Locks & Unlocks Key Locks & Unlocks

Product Description 2227TP 2227K 2227L

Trim Description 230TP* 210K 230L*

3" x 12¹|₁₆" x ³|₃₂" 3" x 4²⁵|₃₂" x ³|₃₂" 3" x 6³|₈" x ¹⁵|₁₆"


Escutcheon Plate Size
(76x306x2mm) (76x121x2mm) (76x162x24mm)

Pull Center to Center 5¹|₂" (140mm) –– ––

Projection 2" (51mm) 2¹⁵|₁₆" (75mm) 2⁵|₈" (67mm)

ANSI Function 05 08 08

Cylinder Type 1¹|₄" Mortise Furnished 1¹|₄" Mortise

Optional Trim
230TP-BE 210K-BE 230L-BE
(See pages 10)

Optional #425 Sex Bolt


Quantity for Device 2 2 2

* ANSI/BHMA A156.3 (2001) Grade 1 Trim 7


2227-F Surface Mounted Vertical Rod Fire Exit Device

2227-F surface mounted vertical rod fire exit device for pairs of doors up to 8’ x 10’ (2438mm x
3048mm), UL listed for Fire Exit Hardware. See page 13 for detailed information on UL listed fire exit
hardware label and door opening size information. Devices are ANSI A156.3, 2001, Grade 1. Fits door
stiles as narrow as 3 ⁵|₈" (92mm), see page 12. See opposite page for available outside trim and device
Top Latch functions.
Specifications
Device Functions Ships ready for all functions; EO, NL, TP, K, L
Device Handing Non-Handed
Device Lengths 3’ (914mm) – see minimum door opening chart at bottom of page
299F Top Strike 4’ (1219mm) – see minimum door opening chart at bottom of page
Door Height 7’ (2134mm) – standard door height
Extension rods available for door heights up to 10’
12" (205mm)
36" (914mm)
Finishes SP28, SP313
Strikes Top 299F (499F LBR) – Dull Black
Bottom 304L – Unfinished
304L
Optional Strikes see page 12
Bottom Strike
Dogging Feature No Mechanical Dogging
Electric Options LX Latchbolt Monitor Switch see page 14
RX Touch Bar Monitor Switch see page 14
RX2 Double Touch Bar Monitor Switch see page 14
ALK Alarm Exit Kit see page 14
Miscellaneous Options LBR Less Bottom Rod see page 14
GBK Glass Bead Kit see page 15
RG Rod Guards see page 15
LG Latch Guards see page 15
Fasteners & Includes 1 ³|₄" (19mm) – 2 ¹|₄" (57mm) Wood & Metal Doors
Sex Bolts (SNB) Optional SNB available for device, see next page for quantities.
Sex Bolts are furnished standard for top and bottom latches.
Latch Bolt Deadlocking Anti-friction Top and Bottom Bolt, ⁵|₈" (16mm) throw
Device Centerline from 39 ¹³|₁₆" (1011mm) at center of device
Finished Floor
Bottom Latch
Door Undercut ¹|₄" (7mm) from finished floor recommended, ³|₄" (19mm)
³|₈" (9mm) maximum
Device Dimensions see page 13

See page 16 for How to Order specification

Minimum Door Opening Chart

Stop Single Double Door Minimum Door Opening Minimum Door Opening
Height Strike Door w/Mullion for 3´ device* w/ALK*
¹|₂´´ N/A Yes Vert. x Vert. 25.875´´ (657mm) 32.625´´(829mm)
⁵|₈´´ N/A Yes Vert. x Vert. 26.000´´ (664mm) 32.750´´(832mm)

*For 4´ device, add 6´´ (152mm)

8 © 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.
2227-F Surface Mounted Vertical Rod Fire Exit Device Trim
Exit only Night Latch Night Latch
Key Retracts Latchbolt Key Retracts Latchbolt
Optional Pull Required

Product Description 2227EO-F 2227NL-F 2227-OP-F

Trim Description –– 210NL** 110NL-MD**


110NL-WD**
5³|₈" x 4²⁵|₃₂" x ³|₃₂"
Escutcheon Plate Size –– ––
(137x121x2mm)
Pull Center to Center –– –– ––
Projection –– 1³¹|₃₂" (42mm) ––

ANSI Function 01 03 03

Cylinder Type –– Rim Rim


Optional Trim
(See page 10) 230EO 230NL ––

*Optional #425 Sex Bolt 6 (with no trim)


2 6
Quantity for Device 2 (with EO trim)
*Additional 425 SNB for 2 2 2
499F strike
* Sex Bolts are required for wood fire doors
** ANSI/BHMA A156.3 (2001) Grade 1 Trim

Thumbpiece Knob Lever


Key Locks & Unlocks Key Locks & Unlocks Key Locks & Unlocks

Product Description 2227TP-F 2227K-F 22L-F

Trim Description 230TP** 210K 230L**

3" x 12¹|₁₆" x ³|₃₂" 3" x 4²⁵|₃₂" x ³|₃₂" 3" x 6³|₈" x ¹⁵|₁₆"


Escutcheon Plate Size
(76x306x2mm) (76x121x2mm) (76x162x24mm)

Pull Center to Center 5¹|₂" (140mm) –– ––

Projection 2" (51mm) 2¹⁵|₁₆" (75mm) 2⁵|₈" (67mm)

ANSI Function 05 08 08

Cylinder Type 1¹|₄" Mortise Furnished 1¹|₄" Mortise

Optional Trim
(See page 10) 230TP-BE 210K-BE 230L-BE

*Optional #425 Sex Bolt 2 2 2


Quantity for Device
*Additional 425 SNB for 2 2 2
499F strike
9
* Sex Bolts are required for wood fire doors
** ANSI/BHMA A156.3 (2001) Grade 1 Trim
22 Optional Trim

210 Series Trim


The 210DT and 210NL have a heavy 10 gauge (2.4mm) stainless steel escutcheon. Cylinder must be ordered separately for the 210NL trim.
The 210K knob trim has a 10 gauge (2.4mm) steel escutcheon and uses the Schlage “A” orbit knob with six pin “C” keyway.

230 Series Trim


The 230EO, 230DT, 230NL and 230TP have a heavy 10 gauge (2.4mm) steel escutcheon. The 230L has a cast aluminum ³|₄” (19mm) depth
escutcheon. #06 lever style furnished standard, #03 style lever is available. 230L furnished RHR if handing is not specified. Cylinder must be
ordered separately for the 230NL, 230TP and 230L trims.

110NL Cylinder Kit


Cylinder kit is available MD for metal doors or WD for wood doors. Metal door application supplied standard if door material is not specified.
When ordering with device, specify function NL-OP. Cylinder must be ordered separately.

Exit Only Dummy Trim Night Latch Thumbpiece Lever Knob


Trim Plate Pull When Dogged Key Retracts Latch Bolt Blank Escutcheon Blank Escutcheon Blank Escutcheon
Always Operable, Always Operable, Always Operable,
no cylinder no cylinder no cylinder

Trim Description 230EO 230DT** 230NL** 230TP-BE** 230L-BE** 210K-BE

Escutcheon Plate Size 3" x 12¹|₁₆" x ³|₃₂" 3" x 12¹|₁₆" x ³|₃₂" 3" x 12¹|₁₆" x ³|₃₂" 3" x 12¹|₁₆" x ³|₃₂" 3" x 6³|₈" x ¹⁵|₁₆" 3" x 4²⁵|₃₂" x ³|₃₂"
(76x306x2mm) (76x306x2mm) (76x306x2mm) (76x306x2mm) (76x162x24mm) (76x121x2mm)

Pull Center to Center –– 5¹|₂" (140mm) 5¹|₂" (140mm) 5¹|₂" (140mm) –– ––

Projection –– 2" (51mm) 2" (51mm) 2" (51mm) 2 ⁵|₈" (67mm) 2 ¹⁵|₁₆" (75mm)

ANSI Function 01 02 03 –– –– ––

Cylinder Type –– –– Rim –– –– ––


*Optional #425 Sex Bolt
2 2 6 –– 2 2
Quantity for Device
*Additional 425 SNB for
2 2 2 2 2 2
499F strike
* Sex Bolts are required for wood fire doors
** ANSI/BHMA A156.3 (2001) Grade 1 Trim
Operation Options Lever Designs

Standard operation, Blank escutcheon, #03 #06


key locks and unlocks lever or knob always Standard
lever or knob. active.
(Classroom) (Passage)
10 © 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.
22 Cylinder Options

Cylinders
Cylinders are not furnished with device or trim (unless noted) and must be specified when ordering. Specify finish when ordering separately.
Only available with Schlage “C” Keyway. Custom Keying not available.

Rim – 3216 Mortise – 3215 (Schlage B502-191 cam)

© 2005 Ingersoll-Rand Co. May be copied for use with specification submittal. 11
22 Strike/Stile Information

Strikes for Rim Devices


264 299 299F 499F

2⁷|₈" 2⁷|₈" 2⁷|₈" 3⁷|₁₆"


(73mm) (73mm) (73mm) (87mm)

1¹|₄" 1¹|₄" 1¹|₄" 1¹|₂"


1¹|₄" or
(32mm) (32mm) (32mm) (32mm) (38mm)
Projection 9/16" (14mm) Projection 13/16" (21mm) Projection 13/16" (21mm) Projection 15/16" (23mm)

1408 1410 – Integral Stop 1439 – Blade Stop*** 1606

3⁷|₁₆" 2⁷|₈"
(87mm) 3³|₁₆"
(81mm) 1³|₄" (35mm) (73mm)

1⁷|₈" 1³|₈"
1³|₈" (48mm) (35mm)
(35mm)
One per pair of doors Projection 1/2" (13mm) Projection 1/2" (13mm) Projection 3/8" (10mm)
1609**

3¹|₄"
(83mm)

1¹|₁₆"
(27mm)

Strikes for Vertical Rod Devices


248L-4 260U – Flush Transom Only 304L 385A
Available for FEH
1⁷|₈" 2"
2¹|₂" 2¹|₂"

1⁷|₈" 2¹|₄"
⁹|₁₆" 1⁵|₈"
Projection 3/8" (10mm) Projection 3/8" (10mm) Mortise 13/16" (21mm) Mortise 2-1/2" (64mm)

Strikes 264, 299, 299F and 499F also available for Vertical Rod Devices

DEVICE TYPE STANDARD STANDARD OPTIONAL OPTIONAL


SINGLE DOOR DOUBLE DOOR SINGLE DOOR DOUBLE DOOR
STRIKE STILE APPLICATION* STILE STRIKE STILE APPLICATION * STILE
1439 3-3/16" (97mm) 299 w/5654 4-1/4" (108mm)

1410 3-3/16" (97mm) 1408 w/5754 3-3/16" (97mm)


22
299 4-3/4" (121mm) 299 w/4954 4-3/4" (121mm)
1606 3-15/16" (100mm) 1606 w/1654 4-1/4" (108mm)

1609 w/vertical rod**


–– –– 4-3/8" (111mm)

22-F 299F 4-3/8" (111mm) 499F w/9954 4-7/8" (124mm) –– –– –– ––

299 Top
2227 LATCH RETRACTION 304L Bottom or 3-5/8" (92mm) Two Vertical Rods 3-5/8" (92mm) 3-5/8" (92mm) Two Vertical Rods 3-5/8" (92mm)
248L4 Bottom 260U Top
385A Bottom
299 Top
2227 PULLMAN LATCH 248L4 Bottom
3-5/8" (92mm) Two Vertical Rods 3-5/8" (92mm) 260U Top 3-5/8" (92mm) Two Vertical Rods 3-5/8" (92mm)

299F Top
2227-F 304L Bottom
3-5/8" (92mm) Two Vertical Rods 3-5/8" (92mm) –– –– –– ––

*Mullion information, refer to General and Auxiliary Catalog.


**Not for UL Fire Exit Hardware. Must be used with a coordinator.
*** Replaces 1409 Strike
NOTE: On a Rim/Vertical Rod application for a pair of doors, the 1609 strike extends off the edge of the door into the opening.

12 © 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.
UL Listings, Grade, Type, Function Options and Dimensions

UL Listed Fire Exit Hardware Label and Opening Size


Double Door

Exit Device Door Material Single Door With Mullion **Same Direction Double Egress
22-F HM 3 Hour 4’ x 8’ 3 Hour 8’ x 8’ –– –– –– ––
22-F WD 90 MIN. 4’ x 8’ 90 Min. 8’ x 8’ –– –– –– ––
2227-F HM –– –– –– –– 90 Min. 8’ x 10’ 3 Hour 8’ x 10’
2227-F WD –– –– –– –– *20 Min. 8’ x 10’ *90 Min. 8’ x 9’
2227-F WD –– –– –– –– *90 Min. 8’ x 9’ –– ––
2227-F-LBR HM –– –– –– –– 90 Min. 8’ x 10’ 3 Hour 8’ x 10’
2227-F-LBR WD –– –– –– –– *20 Min. 8’ x 10’ *90 Min. 8’ x 9’
2227-F-LBR WD –– –– –– –– *90 Min. 8’ x 9’ –– ––

*UL listing for wood doors may be for a specific door manufacturer. Consult wood door manufacturers for current UL listings
**Currently, no door manufacturer offers a listing over 90 minutes with doors swinging same direction.

ANSI Grade, Type & Function Door Handing


Function Grade 1, Type 1 Grade 1, Type 2

01 22EO, 22EO-F 2227EO, 2227EO-F

02 22DT 2227DT

03 22NL, 22NL-F 2227NL, 2227NL-F

05 22TP, 22TP-F 2227TP, 2227TP-F

08 22K, 22K-F 2227K, 2227K-F

22L, 22L-F 2227L, 2227L-F 2¹|₈"


08 (54mm)
Vertical Rod Dimensions
Vertical rods are
4¹|₂"
¹|₂" (13mm) square tubing (114mm)
Dimensions
1¹|₂"
(38mm)

37⁷|₁₆"
(951mm)

33⁷|₁₆"
(842mm)

© 2005 Ingersoll-Rand Co. May be copied for use with specification submittal. 13
22 Options & Accessories

Less Bottom Rod – LBR Vertical Rod and Latch Guard — RG-27
LBR option for fire exit devices is available using a spring loaded Series RG-27 Vertical Rod and Latch Guards protect
auxiliary latch bolt installed in the lower door edge. When exposed the bottom rods of exit devices from the damaging
to heat the auxiliary latch bolt releases, keeping the doors in alignment impacts of carts or gurneys passing through doors.
and closed during a fire. See page 13 for detailed information on UL If bottom rods become damaged, the exit device
listed fire exit hardware label and door opening size information. will not function as intended and can jeopardize the
LBR devices for fire exit devices ship standard with a 499F top strike ability to exit safely during an emergency.
and less bottom strike. In addition to protecting the vertical rod, the guard
36" provides a smooth, unobstructed surface so the
LBR devices must be ordered in pairs of vertical rod devices, or
(914mm) door can be pushed open easiliy with the bumpers
must be used in conjunction with an approved automatic or
constant latching flush bolt. of a wheelchair. The standard latch guard features a
45˚ ramp and continuous ramp on full width or
Less Dogging – LD extended latch guard.
Less dogging ia available on all 22 series panic exit devices. To All stainless steel construction in US32D finish.
order, use prefix LD. Example LD22EO Latch guards can cover latches as large as
Rod Guard 1¹|₄"W x 10"H x 1⁷|₈" projection. For use on Hollow
Metal Fire-Rated Doors.
Pullman Latch – PL
Pullman latches are always extended and are most commonly used
in conjunction with electric strikes and LBR-less bottom rod applications. 33 ¹|₈" (841mm) – 3' (914mm) door
Not available with fire rated exit devices. Pullman latches do not 45 ¹|₈" (1146mm) – 4' (1219mm) door
deadlock and are not recommended for applications where security
may be compromised. When the PL is specified the standard latches
are replaced with Pullman style latches at an additional charge. See
Pricebook for details.
12" (305mm)
Glass Bead Kit – GBK
Extended Latch Guard
Glass Bead kits are used on doors with raised glass beads. Each kit
consists of ¹|₄” (6mm) shim sets. GBK for surface vertical rod devices 2 ¹|₄" (57mm)
ship with ¹|₈” (3mm) shims for rod guides. Shims are not required for
Top and Bottom latches 10´´
(254mm)

4 ³|₈"
(111mm)
Latch Guard

Models
To order, specify: RGO — Rod guard only (Projection 1³|₁₆" (30mm) ).
1. With device specify GBK in device description. RG-27 — Rod and latch guard.
2. To order separately, specify model 22GBK-R (rim), 22GBK- RG-27-3 — 3' (914mm) Rod Guard
499F (rim), 22GBK-SV (vertical rod) and Extended Latch Guard.
RG-27-4 — 4' (1219mm) Rod Guard
3. Finish, SP28 or SP313
and Extended Latch Guard.

Cover Plate Kit – 229 LGO — Latch guard only.


LGO-3 — 3' (914mm) Extended latch guard only.
Kit contains inside and outside plates for hinge stile cutouts, an LGO-4 — 4' (1219mm) Extended latch guard only.
inside plate for the lock stile, and necessary screws. Plates are
designed to cover cutouts required by most existing exit device Note: Not for use on wood fire doors
installations.
To Order, Specify:
1. Model number.
2. Handing (except on RGO).
3. Door material if other than Hollow Metal.
4. Optional sex bolt mounting available.

14 © 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.
22 Electrical Options

Alarm Kit – ALK Electrical Power Transfer – EPT

The ALK battery alarm kit is a simple yet effective way to deter
unauthorized use of an opening. While the exit device is still a means of
egress, the ALK kit contains an internal horn. When the touch bar is
depressed, the horn sounds to provide an audible means of signaling
that the opening has been violated. The alarm kit can be armed or
disarmed by key thus allowing the exit device to be set in an armed or
disarmed mode. The horn is rated at 85 decibel. Standard Hex Key
dogging not available when using an ALK.
The key switch uses a standard 1¹|₄" (32mm) mortise UL Listed (GVUX) – Miscellaneous Fire Door Accessories
cylinder with a straight cam (Schlage Cam reference B502-191).
The unit operates on one standard 9-volt alkaline battery. When the
Electric Power Transfer provides a means of transferring electrical power
battery is weak, the horn will emit an intermittent low battery alert signal.
from a door frame to the edge of a swinging door. The units are completely
Alarm kits are furnished standard with a RX-request to exit switch. concealed when the door is in the closed position, and are ideally suite for
Optional LX-Latch bolt monitoring, or RX2-double request to exit installations involving abuse or heavy traffic.
monitor switch are available. LX latch bolt monitoring is recommended
for use with surface vertical rod exit devices. Two models are available; EPT-2, two 18 gauge wires and EPT-10,
ten 24 gauge wires.
The ALK includes “EMERGENCY EXIT ONLY, ALARM WILL SOUND”
decal for application on the door. Door applications:
The ALK is available with two optional circuit boards. External Inhibit (EI) up to 5" butt hinge – 180˚ swing
allows for the use of external switch to be used to arm, disarm and reset 5¹|₂" butt hinge – 130˚ swing
the alarm. Auto Reset (AR) rearms the alarm after a preset time. Auto 6" butt hinge – 110˚ swing
Reset is available in three factory set times, 1¹|₂, 3 or 6 minutes. ³|₄" offset pivot – 180˚ swing

The ALK can also be hard wired and powered using a PS9 power supply.
See PS9 on this page for additional information. Not for use with swing clear hinges or center hung pivots

To Order, Specify: Finishes


1. With device, specify ALK SP28 (sprayed aluminum)
2. To order separately, specify model 22ALK or SP313 (sprayed duranodic).
3. Specify Options EI or AR, Example: ALK-AR. For AR option
specify factory set time (1¹|₂, 3 or 6 minutes)
4. Door size other than 3’ Dimensions
5. Switch if other than RX Housing 9" x 1 ¹|₄" x 1 ⁵|₈" (229mm x 32mm x 38mm)
6. Finish, SP28 or SP313 EPT-2 Two 18 gauge wires
Up to 2 amps @ 24 VDC with a
Minimum door opening sizes on ALK applications – 16 amp maximum surge
refer to device pages 2, 4, 6 and 8.
EPT-10 Ten 24 gauge wires, Up to 1 amp @ 24VDC
with a 16 amp maximum surge
Power Supply – PS9
To order, specify:
The PS9 is an AC power supply that provides 9 VDC power to operate
1. EPT-2 or EPT-10.
the ALK alarm kit. The unit will power one or two alarm kits. Included is
a 9-volt sealed battery that provides backup power in case of an AC 2. Finish, SP28 or SP313.
power failure.

© 2005 Ingersoll-Rand Co. May be copied for use with specification submittal. 15
22 Electrical Options

Request to Exit — RX

The RX (Request to Exit) feature is used to signal the use of an opening.


This device is equipped with one internal SPDT switch which
monitors the pushpad.
The device can be connected to a security console, or may be used as a
single door alarm when used with a horn and power supply. A continuous
current electric transfer must be used for transferring power from the
frame to the door.
The RX switch option should not be used to control a load, but as a
signaling switch (0.5 amps. resistive maximum).
The RX switch is available in a low current (LC) switch. Most commonly
used in computer operated monitoring systems.

To Order, Specify:
1. Standard – Use prefix RX, example RX22EO
2. Low Current – Use prefix RX-LC, example RX-LC22EO
Double Request to Exit — RX2
The RX2 feature uses 2 RX switches.
To Order, Specify:
1. Standard – Use prefix RX2, example RX22EO

Latch Bolt Monitoring — LX

The LX feature is used to signal the use of an opening. This device is


equipped with one internal SPDT switch which monitors the latch bolt.
The device can be connected to a security console, or may be used as a
single door alarm when used with a horn and power supply. A continuous
current electric transfer must be used for transferring power from the
frame to the door.
The LX switch option should not be used to control a load, but as a
signaling switch (0.5 amps. resistive maximum).

The LX switch is available in a low current (LC) switch. Most commonly


used in computer operated monitoring systems.

To Order, Specify:
1. Standard – Use prefix LX, example LX22EO
2. Low Current – Use prefix LX-LC, example LX-LC22EO

Electrical Rating for all Switches:


• Standard – up to 0.5 Amp @ 24VDC Maximum
• Low Current (LC) - up to .05 Amp @ 24VDC Maximum

Note: All Switches can be either factory or field installed

16 © 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.
22 Popular Door Applications

Popular Double Door Applications

Two rim devices with mullion— Two vertical rods—double egress, panic or fire
same direction, panic or fire device device

Two surface mounted vertical rod


devices—same direction, panic or fire device
(do not use with overlapping astragal)

Auxiliary Fire Latch

Two FEH vertical rods with auxiliary fire latch—


LBR option
17
22 Additional Information

Nomenclature – How To Order


RX 22 27 L F SP28 RHR 03 ALK SNB 3´6´´ 7´2´´ WD
LD –– Less Dogging
LX — Latch Bolt Monitoring
LXLC –– Latch Bolt Monitoring, Low Current
RX — Request to Exit
RXLC –– Request to Exit, Low Current
RX2 –– Double Request to Exit

22 — Series 22

None — Rim Device


27 — Surface Mounted Vertical Rod Device

DT — Dummy Trim
EO — Exit Only
K –– Knob (Classroom)
K-BE –– Knob-Blank Escutcheoon
L — Lever (Classroom)
L-BE –– Lever-Blank Escutcheon
NL –– Night Latch (Key retracts Latchbolt)
NL-OP — Night Latch Cylinder Assembly – Optional Pull
TP –– Thumbpiece
TP-BE –– Thumbpiece-Blank Escutcheon

None — Panic Exit Device


F — Fire Exit Device

Finish –– SP28, SP313

Handing — RHR, LHR

Lever Style — #06 (standard), #03

Option(s)
LBR — Less Bottom Rod
SNB –– Sexbolts
ALK –– Alarm Kit
GBK –– Glass Bead Kit
CYL –– Cylinder
PL –– Pullman Latch
SEC –– Security Screws
–– Optional Trim
–– Optional Strike

Door Specifications:
Door Width –– 3’ (Standard), advise if different

Door Height –– 7’ (Standard), advise if different

Door Thickness –– 1³|₄” (Standard), advise if different

Door/Frame Material:
HM –– Hollow Metal (standard)
WD –– Wood
AL –– Aluminum

Device Ctr. Line –– See specifications, advise if


different than standard

Door Application:
SGL –– Single (Standard for Rim)
PR –– Pair (Standard for Surface Vertical)
DE –– Double Egress

Door Listings –– 3 Hour


–– 1¹|₂ Hour
–– 1 Hour
–– 45 Minute
–– 20 Minute

18 © 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.
22 Series Notes

© 2005 Ingersoll-Rand Co. May be copied for use with specification submittal. 19
22 Series Notes

20 © 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.
22 Series Exit Devices
International Offices
Canada / Latin America
IR Security & Safety
1076 Lakeshore Road East
Mississauga, Ontario,
L5E 1E4, Canada
(905) 403-1800
(905) 278-1413 FAX
(877) 590-4734

North-East Asia
IR Security & Safety
23/F, 625 King’s Road
Northpoint, Hong Kong
+(852) 2235-0600
+(852) 2565-1409 FAX

South-East Asia / Australia / NZ


IR Architectural Hardware Ltd.
P.O. Box 19-347
437 Rosebank Road,
Avondale, Auckland, New Zealand
Visit Von Duprin on the web
+64 (0) 9-829-0550
+64 (0) 9-829-0552 FAX
www.vonduprin.com
www.irarchitecturalhardware.co.nz or contact an
Mexico IR Security & Safety Consultant
IR Security & Safety 1-877-840-3621
Blvd. Centro Industrial No. 11
Puentas de Vigag, Tlalnepantla
Estado de Mexico, 54070 Mexico
+525-5-8503-6614

Europe / Middle-East / Africa


IR Security & Safety Ltd.
Bescot Crescent
Walsall, West Midlands WS1 4DL
United Kingdom
+44 (0)1922 707400
+44 (0)1922 646303 FAX
www.irsecurityandsafety.co.uk

VON DUPRIN
Administrative Offices
2720 Tobey Dr.
Indianapolis, IN 46219
317-613-8944
317-613-8302 Fax
Customer Service
800-999-0408
800-999-0328 Fax
Technical Support
888-371-7331
317-613-8509 Fax

©2005 Ingersoll-Rand VD-GN-1002 Rev. 3/05 Printed in USA

You might also like