INDIRECT HEATER SPECIFICATION SHEET

Project Number :
Revision: A
Customer

Location
THERMAL DESIGN
FLUID TO BE HEATED Well Head Natural Gas
TOTAL FLUID ENTERING
INLET OUTLET Gas Coils Data:
Gas Flow Rate 5.00 MMScfd 5.00 Intermediate Choke Yes
LIQUID - Water 40.00 Bpd 40.00 Post Choke Temperature 80 o
F
LIQUID - Condensate Oil 2.5 Bpd 2.5 Choke Inlet Pressure 1,000 Psig
Gas Temperature 100 o
F 100 Pressure Drop (allowable) 750 Psi
Gas Density/Spec. Grav. 0.6 Sp. Grav. 0.6 Type of Fuel Natural Gas
Liquid Water Density 1 Sp. Grav. 1 LHV / HHV of Fuel 980 Btu/Scf
Oil Density/oAPI/Sp. Gr. 52 oAPI 52 Bath Medium Water+Ethylene Glylcol
Gas Viscosity Centipoises Design Bath Temperature 190 o
F
Liquid Water Viscosity Centipoises
Oil Viscosity Centipoises
Water Therm Conductivity Btu/Hr-Ft2/oF
Oil Therm Conductivity Btu/Hr-Ft2/oF
Oil Specific Heat Btu/Lb-oF
Water Specific Heat Btu/Lb-oF

MECHANICAL DESIGN ELECTRICAL DESIGN / AREA CLASSIFICATION


Design Pressure: Power Available:
First Coil Pressure 6,170 Psig Voltage N/A
Second Coil Pressure 6,170 Psig Phase N/A
Design Temperature: Hertz N/A
First Coil Inlet Temp. 100 o
F Area Classification:
Second Inlet Coil Temp 80 o
F Class II
Crossion Allowance 0.250 inch. Division 2
Design Code (ASME, API, DOT) ASME Group D
Temperature T4A
ENVIRONMENTAL DESIGN CIVIL DESIGN
Allowable Noise 85 dba Elevation, ASL Unk. feet
Allowable Emissions: Ambient Temperature 95 - 110 o
F
NOX Lb/hr Wind Speed 100 Mph
CO2 Lb/hr OnShore / OffShore OnShore
HydroCarbons Lb/hr Seismic Zone 4 (0 - 4)
H2S Lb/hr

BURNER TYPE MISCELLANEOUS


Natural Draft Yes Skid Mounted Yes
Forced Draft No Stack Type Ell
Control Type Pneumatic

ACCESSORIES CONTROL PANEL


Standard Supply No Required Yes
Custom Design Yes NEC / NEMA Rating
Options: Type
Bath Low Level Switch Yes Ignitor Yes
Fuel Meter Yes Burner Management Unkn.
Stack High Temp Switch Yes PLC w/B.M. & Temp Control Unkn.

Page 1 of 3
Flame Arrestor Yes PLC W/ DCS Communications Unkn.

Page 2 of 3
In-Line Heater Sketch:

F
H

A Gas inlet

E
Gas outlet
B

Nozzles' Schedule:

Size Facing Type Class


A Wellhead Gas Inlet 4" Raised Face Flanged 2500 #
B Gas Outlet 4" Raised Face Flanged 150 #
C Fuel gas inlet 2" Raised Face Flanged 150 #
D Fuel gas outlet 2" Raised Face Flanged 150 #
E Temperature Indicator ¾" N/A Screwed 3000 #
F Water bath Fill Unk. N/A N/A N/A
G Drain 2" N/A Screwed 150 #
H Thermostat ¾" N/A Screwed 3000 #
I Choke inlet 4" Raised Face Flanged 2500 #
J Choke outlet 4" Raised Face Flanged 150 #

ADDITIONAL NOTES:
1. All process coils are to be removable
2. Designer / Fabricator to state max. design heating Flux on fire tube
3. Unit to be skid mounted and complete for field installation and hook up.
4.Unit shall have pre-piped ability to be flow by-passed with exception that built in heater choke shall remain in service.
5. Heater Choke valve shall be Long-nose (if possible) adjustable choke (manual handwheel).
6. Heater shell shall be insulated and protected by corrugated metal
7. Heater will have auxilliary coil for heating fuel and instrument natural gas

Page 3 of 3