Professional Documents
Culture Documents
TABLE OF CONTENTS
(TOC)
FAULT SYMPTOMS
COMPONENT
FAULT ISOLATION
LOCATION
REMOVAL/INSTALLATION
(REF. AMM)
NOTE: In some systems, a BITE PROCEDURE description assists the fault isolation.
X-REF TO
FAULT
SYMPTOMS
The ATA REF column in the TOC for PACK TEMPERATURE CONTROL cross-references to 21-61, which is the FAULT SYMPTOMS page ( (Ref. Fig. 103
SHEET 01
X-REF TO
FAULT
ISOLATION
On this page, the "NORMAL" operation is shown by a horizontal line leading to the word "NORMAL".
The fault symptom noted is the following : (Ref. Fig. SHEET 01
YES 21 61 00
FIG. 102
NO 21 61 00
FIG. 103
Figure 00-00-00-002 / SHEET 01/1 - Examples of TSM use
** ON A/C ALL
)
The answer YES or NO corresponding to the symptom noted directs the user to the FAULT ISOLATION mentioned on the right-hand side of the page ( (Ref.
Fig. 104 SHEET 01
OUT
ON
NOTE: - Fault Symptoms (FS) are normally shown on a single page. Depending on the number of the fault isolation se-
quences, a Fault Symptom may be split into two sheets.
- In a sheet, dotted lines denote that a part of the considered Fault Symptoms are referred to the other sheet.
For similarity between the two sheets, PREREQUISITES are repeated as well as the text at the top of columns.
The NORMAL state operation line is also boxed.
- Fault symptoms of some chapters directly cross-refer to the numbered blocks located in the FAULT ISOLATION
pages. These blocks are associated with the ATA REF, Fig. number of the Fault Isolation ( (Ref. Fig. 106 SHEET
01) ).
(b) Prerequisites
At the top of the FS, the prerequisites indicate the configuration in which the A/C must be when trouble shooting is commenced and also the list of the C/
Bs that must be closed.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION
BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR INJURE PERSONS.
WARNING: MAKE SURE THAT YOU DO THE DEACTIVATION OF THE THRUST REVERSER
BEFORE YOU DO MAINTENANCE WORK ON OR AROUND THE THRUST
REVERSER. IF YOU DO NOT DO THIS PROCEDURE, THERE IS A RISK OF
UNWANTED OPERATION AND THUS OF INJURY TO PERSONS AND DAMAGE TO
EQUIPMENT.
WARNING: YOU MUST OBEY ALL THE SAFETY PROCEDURES WHEN YOU DO WORK
IN OR NEAR THE FUEL THANK. IF YOU DO NOT OBEY THE SAFETY
Specific instructions for the wiring check are given where necessary.
These include values (eg. resistance) and connector/pin numbers where applicable. If no specific instructions are given for the wiring check, the check
must include a continuity test ( ESPM 20-52-21 ) and a test for short circuit ( ESPM 20-52-22 )
(Ref. Fig. SHEET 01)
(Ref. Fig. SHEET 01)
(Ref. Fig. SHEET 01)
(Ref. Fig. SHEET 01)
(Ref. Fig. SHEET 01)
Figure01 - - Example