You are on page 1of 2

Sample of Instruments We Calibrate…..








Thermo-Hygrometers
T/RH Probes and Measuring Devices
T/RH Data Loggers
Dew Point Meters
T/RH Chart Recorders
PRT, RTD, TC Probes
Microbaths, Dryblocks, Ovens
Calibration
Accuracy
Repair Services
Your Trusted
Service Partner 1


Infrared Thermometers
Multimeters
Cost-Effectiveness CALIBRATION
• Megohmmeters On-site Calibration Services Cost-Effectiveness
• Current Clamps Reliability CUSTOMIZED SOLUTIONS
• Process Meters Accuracy REPAIR SERVICES
Customized Solutions
• Resistors
ON-SITE


Tachometers
Manometers
CALIBRATION SERVICES
• Gauges Corporate Headquarters
Reliability
• Calibrators 361 Steelcase Road West, Suite 6
Markham, Ontario L3R 3V8
• Differential Gauges
tel: (905) 477-2133
• Transmitters/Transducers fax: (905) 477-4219
• Vacuum Gauges
Toll Free: 1-800-567-8686
• Barometers
www.alphacontrols.com
• Particle Counters alphacal@alphacontrols.com
• Gas Detectors
Montréal
• Flow Meters and Controllers télé : (450) 621-3626
• Variable Area Meters (Rotameters) téléc : (450) 621-4089
Serving Canadian industry for over 30 years
• Bubble Meters www.alphacontrols.com
Humidity: Temperature:
Calibration Accreditation & Commitment • 10 to 95% RH: ±0.5% RH • Range:
At Alpha, we believe we are the best calibration to Quality • Dew Point Temperature: -196 to 660°C: ±0.01°C
service provider in the industry, and we’re ready to 660°C to 1200°C: ±2.3°C
Alpha Controls & Instrumentation Inc. is an ISO 9001 -30 to 30°C: ±0.1°C
prove it! We stand behind everything we do. Every
calibration lab can offer you technicians and test registered company and its calibration services are • Ambient Temperature: • Infrared:
equipment. But you need more. More accuracy. Fast accredited to ISO/IEC 17025 by the American Association -30 to 60°C: ±0.1°C -15 to 500°C: ±0.5°C
turnaround times. Service designed to meet your for Laboratory Accreditation (A2LA), one of the most
stringent accreditation authorities that is accepted • Fixed Points:
specific needs and most importantly, calibration Electrical: LN2, Hg, TPW, Tin, Zinc, Al
services you can trust. worldwide. By achieving these quality objectives, Alpha is
• Voltage:
fully committed to comply with all of your company and or
Our Metrologist’s boast the highest level of accreditation and use only 1000 V AC/DC
industry needs. Pressure:
state-of-the-art technology from the proven world leaders in • Current:
• A2LA Accreditation to ISO/IEC 17025 (scope # 2260.01) • Gauge/Absolute:
calibration instrumentation. Combined with our unparalleled technical 1000 A AC/DC 0 to 300 psig/psia: ±0.009% rdg.
service, support and competitive pricing, you get a complete • ISO 9001:2008 registration for all our quality
calibration experience. • Resistance:
management processes • Differential:
0 to 2 GOhms
• Standard calibration procedures for all calibrations -60 to 60 in W.C.: ±0.00015 in W.C.
Service performed • Capacitance:
• Barometric:
0 to 110 mF
Test & measurement instruments drift over time, but you can’t afford • Fully trained Metrologists 750 to 1150 mbar: ±0.11 mbar
errors. You depend on accuracy and reliability. Whether you need to • RTD/TC:
• MET/CAL Calibration Management Software • Vacuum :
calibrate every year or every three months, you can count on Alpha to Pt100, J, K, T and more
get the job done in a timely fashion and provide exceptional customer • Meets ISO17025 & ANSI/NCSL Z-540-1-1994 & 0 to 30 in Hg: ±0.003 in Hg
• Frequency:
service. Operate at peak efficiency by making Alpha Controls & ANSI/NCSL Z-540.3-2006 requirements
0 to 225 mHz • Hydraulic:
Instrumentation your one-stop shop for all your calibration needs. • Full calibration and service support 100 to 10,000 psig: ±0.025% rdg.
• Competitive pricing • Reference standards with accuracies that suit all your Particles:
• Excellent turnaround times (expedited service available) calibration needs • Sizes: Gas:
• On-site calibration services • NIST traceable reports 0.1 µm to 25 µm: ±5% • Methane, Oxygen, Hydrogen Sulfide, Propane,
• Full calibration reports with test uncertainty values R 507 (refrigerant), Carbon Monoxide, Carbon
• Pick-up & delivery services are available Flow (Gas): Dioxide, Penthane, Nitrogen and others
How does an A2LA accreditation benefit
• Online quote feature (we will get back to you within the hour)* • 0-100 SLPM: +/-0.2% rdg
you as the customer?
• Automated calibration due notices
• Minimizes risk
• Technical competence of staff
• Provides confidence in the measurement results
• Traceability of measurements and calibrations to
“Calibration services you can trust” national standards www.alphacontrols.com
*during business hours
• Quality assurance of calibration data

You might also like