Professional Documents
Culture Documents
SBF1
Working Load carry by column A (PA)= 222.08 KN Factored load (PAu)= 333.12
Working Load carry by column B(PB)= 319 KN Factored load (PBu)= 478.80
sizeof column A x-dir A 300 mm
y-dir A 300 mm
size of column B x-dir B 300 mm
y-dir B 300 mm
c/c distance between column A & B (x')= 4.275 m
consdering;
unit weight of soil (We)= 20 KN/m2
Angle of repose (φ) = 30 degree
safe bearing of capacity of soil(sqc)= 100 KN/m2
characteristic strength of concrete(fck)= 20 N/mm2
characteristic strength of steel(fy)= 500 N/mm2
1. Depth of foundation:
((1−𝑠𝑖𝑛𝜑)/(1+𝑠𝑖𝑛φ))^2
h= 𝑄�/𝑊𝑒 ∗
= 0.556 ≅ 1m
The base of foundation is located at the depth of 1m below which soil is not subjected to seasonal volumn
changes caused by alternate wetting and drying;
2. Footing dimensions:
d= 186.79 mm
b.Thickness of footing based on one way shear
The effective thickness of footing may be determined by considering that the shear is resisted without
shear reinforcement as follows;
𝑉�,𝑚𝑎𝑥=𝜏�𝑐 𝑏� �
or; d= (𝑉�,𝑚𝑎𝑥)/(𝜏�𝑐 𝑏�)
where; Vu,max= maximum ultimate shear per unit width at a section at distance d from the face of beam
= Pu(0.5B-0.5b-d)
here; Pu= 136.36 KN/m2
B= 2.00 m
b= 350.00 mm
Taking ; bo= 1.00 m
𝜏�𝑐 = shear strength of concrete in foundaation
= k which may be taken as 1.0 for assumed total depth ≥ 300mm *shear strength of concrete
which may be taken as its minimum value of 0.36 N/mm2 on consideration that the
flexural reinforcement shall be small due to large depth of foundation slab on shear consideration
= 0.36 N/mm2
Therefore; �∗𝑏0= (𝑃�(0.5𝐵−0.5𝑏−�)∗𝑏�)/(𝜏�𝑐∗𝑏�)
or, d= 0.2266 m
Therefore; the thickness of footing is governed by one way shear.
Hence; d= 226.65 mm
and , D= 226.65 mm + clear cover of 50mm + (assumed diameter)/2
Providing 12 mm φ at a clearcover = 50 mm
D= 282.65 mm
consider; D= 550 mm
effective depth (d) = 494 mm
A uniform thickness of 550 mm upto a distance of 494 mm
and then it is reduced linearly to 200mm at the edge; (from the face of footing beam)
Provided overall depth (D) = 550 mm d= 494 mm
Mu/bd2 = 0.380
Percentage of steel required
pt % 0.089 % < pt,lim = 0.758 % ( for Fe=
Ast = 442.01 mm2
Spacing of 12 mm φ bar 255.86 mm c/c
d = 612 mm
let , 20 mm ∅ at a clearcover of = 50 mm
overall depth = 671.80 mm
Provide an overall depth of = 700 mm
Thus, effective depth = 640 mm
𝑀�/(𝑏�^2)= 2.431
(𝑃𝐵∗𝑥)/(𝑃𝐴+𝑃𝐵)
(𝑃𝐵∗𝑥)/(𝑃𝐴+𝑃𝐵)
<
(𝜏𝑣)
(𝜏𝑐)
𝑀�/(𝑏�^2)=
<
(𝜏𝑐)
∅
KN
KN
N/mm2 )
h of concrete
500 N/mm2 )
N/mm2 )
N/mm2
N/mm2 )
500 N/mm2 )
20 mm ∅
0.701 %
& 450 mm
�1
PA= 333.12 KN PA+PB= 811.92 PB = 478.8
x= 4.275 m
x''= 2.67 m
Y
X
B = 2 m 0.35
X
�1 = 1.402 m �2 = 1.57
Y
fig: strap beam footing
PA = 333.12 KN PB = 478.8
49.2984904 49.29849
40.91 (+)
(-)
-292.21 -214.75
fig: shear force diagram(KN)
-153.475 -348.47
-149.02
-38.82
3.07
84.549
fig: Bending moment diagramKNm)
350 3-20 mm dia +
mm 2-20 mm dia
3-16mm dia
700 mm
3-20 mm dia+
12mm dia bar@ 150mmc/c bothways 2-20 mm dia
3-16mm dia
550 mm
200 c
mm o
3-20 mm dia +
2-20 mm dia
3-16mm dia
�2
c
o
KN
KN
3-16mm dia
700 mm
Design of strap footing
SBF1
Working Load carry by column A (PA)= 240.95333 KN Factored load (PAu)= 265.04867
Working Load carry by column B(PB)= 211 KN Factored load (PBu)= 232.14
sizeof column A x-dir A 300 mm
y-dir A 300 mm
size of column B x-dir B 300 mm
y-dir B 300 mm
c/c distance between column A & B (x')= 3.45 m
consdering;
unit weight of soil (We)= 20 KN/m2
Angle of repose (φ) = 30 degree
safe bearing of capacity of soil(sqc)= 150 KN/m2
characteristic strength of concrete(fck)= 25 N/mm2
characteristic strength of steel(fy)= 500 N/mm2
1. Depth of foundation:
((1−𝑠𝑖𝑛𝜑)/(1+𝑠𝑖𝑛φ))^2
h= 𝑄�/𝑊𝑒 ∗
= 0.833 ≅ 1m
The base of foundation is located at the depth of 1m below which soil is not subjected to seasonal volumn
changes caused by alternate wetting and drying;
2. Footing dimensions:
(L1^2)/2+L2*( (x-dirA)/2+x)=(L1+L2)*x"
(L1^2)/2+L2*( (x-dirA)/2+x)= 3.433
(L1^2)/2+ 3.6 L2 = 3.43
substituting the value of L1 as L1= 1.950 -L2
L2^2 + 3.301 L2 + -3.06 = 0
L2 = 0.756 m
L1 = 1.194 m
L1= 2.100 m L2 = 1.50 m
d= 97.16 mm
b.Thickness of footing based on one way shear
The effective thickness of footing may be determined by considering that the shear is resisted without
shear reinforcement as follows;
𝑉�,𝑚𝑎𝑥=𝜏�𝑐 𝑏� �
or; d= (𝑉�,𝑚𝑎𝑥)/(𝜏�𝑐 𝑏�)
Vu,max= maximum ultimate shear per unit width at a section at distance d from the face of beam
= Pu(0.5B-0.5b-d)
here; Pu= 110.78 KN/m2
B= 1.70 m
b= 300.00 mm
Taking ; bo= 1.00 m
shear strength of concrete in foundaation
k which may be taken as 1.0 for assumed total depth ≥ 300mm *shear strength of concrete
which may be taken as its minimum value of 0.36 N/mm2 on consideration that the
flexural reinforcement shall be small due to large depth of foundation slab on shear consideration
= 0.36 N/mm2
Therefore; �∗𝑏0= (𝑃�(0.5𝐵−0.5𝑏−�)∗𝑏�)/(𝜏�𝑐∗𝑏�)
or, d= 0.1647 m
Therefore; the thickness of footing is governed by one way shear.
Hence; d= 164.72 mm
and , D= 164.72 mm + clear cover of 50mm + (assumed diameter)/2
Providing 10 mm φ at a clearcover = 40 mm
D= 209.72 mm
consider; D= 300 mm
effective depth (d) = 255 mm
A uniform thickness of 300 mm upto a distance of 255 mm
and then it is reduced linearly to 200mm at the edge; (from the face of footing beam)
Provided overall depth (D) = 300 mm d= 255 mm
Mu/bd2 = 0.835
Percentage of steel required
pt % 0.200 % < pt,lim = 0.9475 % ( for Fe=
Ast = 510.01 mm2
Spacing of 10 mm φ bar 153.99 mm c/c
d = 266 mm
let , 16 mm ∅ at a clearcover of = 25 mm
overall depth = 299.04 mm
Provide an overall depth of = 300 mm
Thus, effective depth = 450 mm
𝑀�/(𝑏�^2)= 2.010
h of concrete
500 N/mm2 )
N/mm2 )
N/mm2
N/mm2 )
500 N/mm2 )
16 mm ∅
1.061 %
& 450 mm
PA= 265.048667 KN PA+PB= 497.18533 PB = 232.13667
x= 3.45 m
x''= 1.76 m
Y
X
B = 1.7 m 0.3
X
�1 = 2.100 m �2 = 1.50
Y
fig: strap beam footing
PA = 265.048667 KN PB = 232.13667
130.439667 -50.355
28.25 (+)
(-)
-236.80 -141.25
fig: shear force diagram(KN)
-122.092 -108.25
-101.58
37.77
2.12
52.967
fig: Bending moment diagramKNm)
300 3-12 mm dia
mm
2-16mm dia
300 mm
3-12 mm dia
10mm dia bar@ 100mmc/c bothways
2-16mm dia
300 mm
200 c
mm o
3-12mm dia
2-16mm dia
KN
KN
2-16mm dia
300 mm
1
Design of raft foundation
service Load in column B A
Pa = 1168.95 KN
Pb = 844.98 KN
Pc = 2427.243 KN
Pd = 1840.85 KN 19.68 m
size of all column = 400mm*400mm
consdering;
unit weight of soil (We)= 20 KN/m2
Angle of repose (φ) = 30 degree
safe bearing of capacity of soil(sqc)= 100 KN/m2 A C
characteristic strength of concrete(fck)= 20 N/mm2 1m
characteristic strength of steel(fy)= 500 N/mm2
1. Depth of foundation:
((1−𝑠𝑖𝑛𝜑)/(1+𝑠𝑖𝑛φ))^2
h= 𝑄�/𝑊𝑒 ∗
≅
1
= 0.556 1m
The base of foundation is located at the depth of 1m below which soil is not subjected to seasonal volumn
changes caused by alternate wetting and drying;
Moment of inertia
Ix-x = 9482.27 m4
Iy-y = 3464.06 m4
area of raft slab(A)= 262.2497 m2
Therefore;
Mx = Pey = 19825.205 KNm
My = Pex = 8905.950 KNm
P/A = 23.954 KN/m2
soil pressure at different points is as follows:
� = 𝑃/𝐴±𝑀𝑦/𝐼𝑦 𝑥±𝑀𝑥/𝐼𝑥 𝑦
i. corner B-2
σ B-2= 57.744 KN/mm2 < 100 KN/mm2
The bending moment is obtained by using a coefficent of 1/10 and L as center of column distance;
here;
depth of the raft will be governed by two way shear.
1.118 = 1267470 1
(3d+1200)*d
d = 165.336 mm
1.118 = 1753425 2
(2d+1200)*d
d = 175.16 mm
3 for the column A-1
perimeter bo = 2(0.5d+0.5d+300+0.5d+300)
= 3d+1200
τv = 𝑉�/𝑏
��
1.118 = 3640864.5 3
(3d+1200)*d
d = 214.06 mm
1.118 = 2761275 4
(4d+1200)*d
d = 234.93 mm
= 482.4 mm2/m
spacing of reinforcement providing 12mm bar;
= 234.452736 mm c/c
Providing 12mm bar @150mm c/c at bothways in top and bottom.
X 2
10.94 m 1.5 m
B B
ex
ey
Y
20.83 m
D A
12.59 m 2
300 mm
0.5d 0.5d
0.5d
0.5d
0.5d
0.5d
0.5d
0.5d
0.5d
0.5d
0.5d
0.5d
Working Load carry by column A120.6933 KN Factored load (PAu)= 132.7627 KN
Working Load carry by column B 157.1867 KN Factored load (PBu)= 172.9053 KN
sizeof column A x-dir A 300 mm
y-dir A 300 mm
size of column B x-dir B 300 mm
y-dir B 300 mm
c/c distance between column A & B (x')= 2.56 m
consdering;
unit weight of soil (We)= 20 KN/m2
Angle of repose (φ) = 30 degree
safe bearing of capacity of soil(sqc)= 77.88 KN/m2
characteristic strength of concrete(fck)= 25 N/mm2
characteristic strength of steel(fy)= 500 N/mm2
1. Depth of foundation:
h=
= 0.432723 1m
The base of foundation is located at the depth of 1m below which soil is not subjected to seasonal volumn
changes caused by alternate wetting and drying;
2. Footing dimensions:
(L1^2)/2+L2*( (x-dirA)/2+x)=(L1+L2)*x"
(L1^2)/2+L2*( (x-dirA)/2+x)= 4.181543
(L1^2)/2+ 2.71 L2 = 4.181543
substituting the value of L1 as L 2.616573 -L2
L2^2 + 0.186855 L2 + -1.517 = 0
L2 = 1.141628 m
L1 = 1.474944 m
consideL1= 1.5 m L2 = 1.5 m
d= 100.1437 mm
b.Thickness of footing based on one way shear
The effective thickness of footing may be determined by considering that the shear is resisted without
shear reinforcement as follows;
or; d=
where;Vu,max= maximum ultimate shear per unit width at a section at distance d from the face of beam
= Pu(0.5B-0.5b-d)
here; Pu= 92.62667 KN/m2
B= 1.5 m
b= 300 mm
Taking ; bo= 1m
= shear strength of concrete in foundaation
= k which may be taken as 1.0 for assumed total dep300mm *shear strength of concrete
which may be taken as its minimum value of 0.36 N/mm2 on consideration that the
flexural reinforcement shall be small due to large depth of foundation slab on shear consideration
= 0.36 N/mm2
Therefore;
or, d= 0.122786 m
Therefore;the thickness of footing is governed by one way shear.
Hence; d= 122.7855 mm
and , D= 122.7855 mm + clear cover of 50mm + (assumed diameter)/2
Providing 10 mm φ at a clearcover = 40 mm
D= 167.7855 mm
consider; D= 300 mm
effective depth (d) = 255 mm
A uniform thickness o 300 mm upto a distance of 255 mm
and then it is reduced linearly to 200mm at the edge; (from the face of footing beam)
Provided overall depth (D) = 300 mm d= 255 mm
Mu/bd2 = 0.512812
Percentage of steel required
pt % 0.120869 % pt,lim 0.9475 % ( for Fe= 415 N/mm2 )
Ast = 308.2149 mm2
Spacing of 10 mm φ bar 254.8141 mm c/c
d = 286.1045 mm
let , 16 mm at a clearcover of 25 mm
overall depth = 319.1045 mm
Provide an overall depth of = 350 mm
Thus, effective depth 317 mm
2.70846
pt % = 0.72933 % pt,lim 0.9475 % ( for Fe= 500 N/mm2 )
Therefore, Ast = 693.5931 mm2
Provide 3 12 mm + 2 16 mm
2 - legged stirrups of di 8 mm
Sv = 261.7397 mm c/c min of 0.75d 237.75 mm & 450 mm
min. shear reinforcement criteria
302.4732 mm c/c
Provide shear stirrups2- legged stirrups of 8mm dia @ 200mmc/c
to seasonal volumn
balanced section;
resisted without
face of beam
nsideration
m right edge)