You are on page 1of 1

FACTS, FIGURES, & DATA

COMPRESSOR/VACUUM PUMP RFW 120 DV RFW 150 DV RFW 200 DV RFW 260 DV

m³/h 720 860 1240 1600


FREE AIR FLOW cfm 424 506 730 942

FLOW RATE m³/h 680 820 1180 1540


cfm 400 483 694 906
@ 400 MBAR RESIDUAL PRESSURE/60% VACUUM

MAX. DISCHARGE PRESSURE barg 2 2 2 2


psig 29 29 29 29
GAUGE

MAX. DISCHARGE PRESSURE barg 2 2 1.5 0.5


psig 29 29 22 7
V-BELT DRIVE

SHAFT SPEED rpm 1500 1500 1500 1500

POWER REQUIREMENT kw 27.5 30 45 58


hp 37 40 60 78
AT SHAFT @ 0.5 BAR/7.25 PSIG

liters/h 0.2 0.2 0.3 0.4


OIL CONSUMPTION gal/h 0.05 0.05 0.08 0.11

kgm² 0.52 0.52 0.73 0.95


MASS MOMENT OF INERTIA lb.sq. ft 12.34 12.34 17.32 22.54

mbar/% 200/80 200/80 200/80 200/80


MAX. VACUUM CONTINUOUS OPERATION inHg 24 24 24 24

MAX. VACUUM mbar/% 100/90 100/90 100/90 100/90


inHg 27 27 27 27
INTERMITTENT OPERATION (MAX. 15 MIN.)

NOISE LEVEL AT 7 M (22 FT) DISTANCE & dB 68 71 75 76


A 73.5 74 79 82
AT 400 MBAR/0.5 BAR RANGE (18 inHG/7.25 PSIG)

l 7.5 7.5 7.5 7.5


OIL TANK CAPACITY gal 1.98 1.98 1.98 1.98

kg 220 220 280 360


WEIGHT INCLUDING NON-RETURN VALVE lb 485 485 617 794

mm 200 200 350 500


A
in 7.9 7.9 13.8 19.7
DIMENSIONS
mm 735 735 885 1035
L
in 29.0 29.0 35.0 41.0

WATER COOLING SYSTEM DATA


COMPRESSOR/VACUUM PUMP RFW 120 DV RFW 150 DV RFW 200 DV RFW 260 DV

COOLING WATER CIRCULATION l/min 15 15 25 35


gal/min 4.0 4.0 6.6 9.2
QUANTITY PE = 0.5 BAR G (7.25 PSIG)

COOLING WATER CIRCULATION l/min 20 20 29 40


gal/min 5.3 5.3 7.7 10.6
QUANTITY PE = 2.0 BAR G (29 PSIG)

HEAT TO BE DISSIPATED kW 11.5 11.5 19 24


hp 15.4 15.4 25.5 32.2
PE = 0.5 BAR G, 7.5 PSIG

HEAT TO BE DISSIPATED kw 14.5 14.5 20 28


hp 19.5 19.5 26.8 37.5
PE = 2.0 BAR G, 29 PSIG

l 10 10 10 10
EXPANSION TANK CAPACITY gal 2.64 2.64 2.64 2.64

PIPEWORK DIMENSIONS inches 1 1 1 1