You are on page 1of 1

HAHD ENGINEERING & ASSOCIATES

JURUTERA PERUNDING – CHARTERED CONSULTING ENGINEER

PROJECT : TAKER OFF :

C.M.D.'S REINFORCEMENT RATIO

A Pile Caps m3 x 105 kg/m3 30% T32 - Pile Caps


30% T25 - Pile Caps
20% T20 - Pile Caps
20% T16 - Pile Caps
-

B Beams m3 x 250 kg/m3 25% T32 - Beams


20% T25 - Beams
20% T20 - Beams
15% T16 - Beams
10% T12 - Beams
10% T10 - Beams
-

C Slabs m3 x 100 kg/m3 30% T16 - Slabs


40% T12 - Slabs
30% T10 - Slabs
-

D Stairs m3 x 125 kg/m3 20% T16 - Stairs


40% T12 - Stairs
40% T10 - Stairs
-

E Column m3 x 200 kg/m3 40% T32 - Column


25% T25 - Column
20% T20 - Column
15% T10 - Column
-

F Walls m3 x 75 kg/m3 45% T16 - Walls


40% T12 - Walls
15% T10 - Walls
-

G Liquid m3 x 105 kg/m3 25% T25 - Ret Wall


Retaining 25% T20 - Ret Wall
Structure 30% T16 - Ret Wall
(Walls) 20% T12 - Ret Wall
-

H Liquid m3 x 105 kg/m3 25% T25 - Slabs


Retaining 25% T20 - Slabs
Structure 30% T16 - Slabs
(Slabs) 20% T12 - Slabs
-

389949115.xls / CMD RFT RATIO