Self standing tail gas stack 98m high having bade diameter of 4000mm & top diameter of 1300mm
25 8 5 1.3 98 - 96 510
24 8 5 1.3 96 - 92 1020
23 8 5 1.3 92 - 88 1020
22 12 9 1.3 88 - 84 1524
21 12 9 1.3 84 - 80 1524
20 12 9 1.3 80 - 76 1524
19 12 9 1.3 76 - 72 1524
18 12 9 2 72 - 68 2353
17 12 9 2.7 68 - 66 1591
16 12 9 2.7 66 - 62 3181
15 12 9 2.7 62 - 58 3181
14 12 9 2.7 58 - 54 3181
13 16 13 2.7 54 - 50 4235
12 16 13 2.7 50 - 46 4235
11 16 13 2.7 46 - 43 3176
10 16 13 3.35 43 - 41 2630
9 16 13 4 41 - 38 4714
8 16 13 4 38 - 34 6285
7 16 13 4 34 - 30 6285
6 16 13 4 30 - 25 7857
5 20 17 4 25 - 20 9811
4 20 17 4 20 - 15 9811
3 25 22 4 15 - 10 12248
2 25 22 4 10 - 5 12248
1 25 22 4 5-0 12248
2 2
Weight of Zone = π *( 4.000 + 3.968 ) * 7850 * 4.000 = 6285 kg
4
Page 1 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
Load Calculations.
Dead Weight
Self weight of the chimmney shell os taken by staad as per uncorroded thickness & a factor of 1.2
has been applied to self weight to account for the loads due to service platforms,ladders, flueducts etc
Live load
Live load on the service platform = 300 kg/sqm
Considering 1m width of the platform.The live load is calculated and applied as a joint load in the
staad file at level 7.5m, 15m, 22.5m, 30m, 37.5m, 45m, 49.3m
OD of OD of Platform LL on
LVL chimmney Platform area platform
m m m m2 kg Sample calculation
82.5 1.3 3.3 7.222 2166 For Lvl 45m
75 1.3 3.3 7.222 2166 OD platform = 5.5 m
67.5 2.7 4.7 11.618 3485 OD chimmney = 3.5 m
60 2.7 4.7 11.618 3485 Area = 3.14 x ( 5.5^2 -3.5^2 ) / 4
52.5 2.7 4.7 11.618 3485 = 14.1 m2
45 2.7 4.7 11.618 3485 Platform LL = 300 x 14.13
37.5 4 6 15.7 4710 = 4239 kg
30 4 6 15.7 4710
22.5 4 6 15.7 4710
15 4 6 15.7 4710
7.5 4 6 15.7 4710
Wind Load
Wind loads have been calculated in accordence with IS:875-2015 (Part 3) and IS:6533-1989 (Part2)
Page 2 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
Risk Factor k1 = 1
Topography Factor k3 = 1
Cyclone Factor k4 = 1
Combination Factor kc = 1
Page 3 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
3 15 - 10 0.97 42.68 1.1 0.88
2 10 - 5 0.91 40.04 0.97 0.78
1 5-0 0.91 40.04 0.97 0.78
The chimmney is divided into parts of 5m,4.5 & 3.5m. The wind load calculated is applied
as a concentrated load at mid point of each part
The static wind force acting at mid point of kth zone is calculated as follows:
Pst,k = c q k hk dk
Where,
c = Shape factor for the chimmney for circular section = 0.7
qk = Static wind pressure at the midpoint of kth zone
hk = height of kth zone strip(m)
dk = external diameter of chimmney (m)
The wind load is increased by 10% to account for platform & ladders and additional 10% for top 10m
portion to account for streaks
Page 4 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
17 68 - 66 0.7 1.24 2.7 2 4.69 5.625
16 66 - 62 0.7 1.23 2.7 4 9.30 10.229
15 62 - 58 0.7 1.21 2.7 4 9.15 10.062
14 58 - 54 0.7 1.2 2.7 4 9.07 9.979
13 54 - 50 0.7 1.19 2.7 4 9.00 9.896
12 50 - 46 0.7 1.17 2.7 4 8.85 9.730
11 46 - 43 0.7 1.15 2.7 3 6.52 7.173
10 43 - 41 0.7 1.13 3.35 2 5.30 5.830
9 41 - 38 0.7 1.12 4 3 9.41 10.349
8 38 - 34 0.7 1.1 4 4 12.32 13.552
7 34 - 30 0.7 1.08 4 4 12.10 13.306
6 30 - 25 0.7 1.05 4 5 14.70 16.170
5 25 - 20 0.7 1 4 5 14.00 15.400
4 20 - 15 0.7 0.96 4 5 13.44 14.784
3 15 - 10 0.7 0.88 4 5 12.32 13.552
2 10 - 5 0.7 0.78 4 5 10.92 12.012
1 5-0 0.7 0.78 4 5 10.92 12.012
Natural frequency of vibration for self weight = 0.706 cps (from STAAD output file)
Since period for natural oscillation for the chimmney exceed 0.25 sec, the dynamic
effect of wind needs to be considered (cl.No.8.3.1 of IS:6533 (part2)-1989)
Dynamic loads on the structure is calculated for the first three modes of ossicilation for the structure.
The loads due to subsequent modes are assumed to be negligible.
Dynamic wind load acting at the centre of jth zone of the chimmney in the ith mode
of natural oscillation is determined as follows.
Pdyn.ij = Mj ξi ηij ν
Page 5 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
ν = coefficient which take care of space correlation of wind pulsation speed according to
ht. & vicinity of building structures
Dynamic coeffcient ξi is determined from Table 5 of IS 6533 part 2 :1989 depending on parameter ξi'
Ti Vb
ξi'=
1200
Coefficient for space correlation of wind pulsation speed ν is determined from Table 7 of
IS 6533 part 2 :1989 based on parameter ξi'
Note: Value of ν for second and third mode are taken as 1 in accordance with clause 8.3.5
Σ ϒik mk Pst.k
ηij = ϒij
Σ ϒik2 Mk
Page 6 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
and kth zones in the ith mode of
mk = coefficient of pulsation of speed thrust from Table 6 of IS 6533 part 2 :1989
Pst.k = Static wind load on the kth zone
The different modes of oscillation for the structure has been determined with the help of
STAAD Pro software. The values obtained for the first three modes has been considered in design.
Ht mk
upto 10 0.83
upto 20 0.83
upto 40 0.75
upto 60 0.65
upto 100 0.60
upto 200 0.54
The mode shapes for the first three modes are tabulated below.
Page 7 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
7 -0.077 0.119 -0.222
6 -0.054 0.088 -0.184
5 -0.035 0.060 -0.136
4 -0.020 0.036 -0.087
3 -0.009 0.017 -0.044
2 -0.002 0.004 -0.012
1 0.000 0.000 0.000
Page 8 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
Therefore η1j = -0.955 x = 3.82
9.2336
Page 9 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
19 74 0.540 0.600 5.504 1.783 1.829 0.533 -0.993
18 70 0.497 0.600 8.400 2.505 2.824 0.697 -0.914
17 67 0.375 0.600 5.625 1.266 1.909 0.268 -0.690
16 64 0.308 0.600 10.229 1.890 3.817 0.362 -0.566
15 60 0.173 0.600 10.062 1.044 3.817 0.114 -0.318
14 56 0.044 0.650 9.979 0.285 3.817 0.007 -0.081
13 52 -0.070 0.650 9.896 -0.450 5.082 0.025 0.129
12 48 -0.159 0.650 9.730 -1.006 5.082 0.128 0.292
11 44.5 -0.221 0.650 7.173 -1.030 3.811 0.186 0.406
10 42 -0.244 0.650 5.830 -0.925 3.156 0.188 0.449
9 39.5 -0.250 0.750 10.349 -1.940 5.657 0.354 0.460
8 36 -0.251 0.750 13.552 -2.551 7.542 0.475 0.462
7 32 -0.243 0.750 13.306 -2.425 7.542 0.445 0.447
6 27.5 -0.222 0.750 16.170 -2.692 9.428 0.465 0.408
5 22.5 -0.184 0.750 15.400 -2.125 11.773 0.399 0.338
4 17.5 -0.136 0.830 14.784 -1.669 11.773 0.218 0.250
3 12.5 -0.087 0.830 13.552 -0.979 14.698 0.111 0.160
2 7.5 -0.044 0.830 12.012 -0.439 14.698 0.028 0.081
1 2.5 -0.012 0.830 12.012 -0.120 14.698 0.002 0.022
Page 10 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
11 44.5 3.811 0.712 5.521 0.428 3.611 0.406 2.643
10 42 3.156 0.620 3.981 0.396 2.772 0.449 2.417
9 39.5 5.657 0.568 6.538 0.371 4.650 0.460 4.438
8 36 7.542 0.492 7.550 0.334 5.579 0.462 5.941
7 32 7.542 0.396 6.077 0.283 4.731 0.447 5.751
6 27.5 9.428 0.308 5.909 0.232 4.854 0.408 6.568
5 22.5 11.773 0.216 5.174 0.172 4.482 0.338 6.798
4 17.5 11.773 0.140 3.354 0.117 3.056 0.250 5.025
3 12.5 14.698 0.080 2.392 0.070 2.289 0.160 4.013
2 7.5 14.698 0.036 1.077 0.033 1.081 0.081 2.029
1 2.5 14.698 0.008 0.239 0.008 0.254 0.022 0.553
ξi = 3.131
ν = 0.650
Mk = 0.612 Tonnes = 612.00 kg
2
η1j = 4.000 m/s
Therefore,
Pdyn,1j = 3.131 x 0.65 x 4 x 612
= 4982 N
= 4.982 kN
Allowable deflection = L/200 =98000 / 200 = 490 mm > 100.252 mm Hence safe
The design wind forces has been combined in accordance with Cl.No.8.3.7 of IS:6533 (part2)-1989.
as follows
Page 11 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
The design forces at the base of each zone is obtained from STAAD Pro. Software.
The design forces at the base of each zone and the corresponding stresses are computed below.
The allowable stresses for the sections are calculated as per Cl.No.7.7.2 and ANNEX C
of IS:6533 (part2)-1989.
2
Yield Stress of Steel = 250 N/mm
Page 12 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
Weld Efficiency = 0.8
Page 13 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
= 85.8 N/mm2
Stress due bending = 9946 x 10^6 = 61.51 < 85.8 N/mm2 Hence Safe
1.62E+08
Therefore 16 mm thick plate is OK
Total Stress in Compression = 61.51 + 3.88 = 65.39 < 85.8 N/mm2 Hence Safe
Total Stress in Tension = 61.51 - 3.88 = 57.63 < 120 N/mm2 Hence Safe
4M
Tensile force to be resisted by bolts = - W
d
4 x 21056.2
= - 1388.5
4
Page 14 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
= 19667.7 kN
4 x 21056.2 1388.5
+ = 2023.58 kN
3.14 x 4^2 3.14 x 4
Allowable plate bending stress, fbs = 0.75 x fy = 0.75 x 240 = 180 N/mm2
Page 15 of 16
550 TPD SAP WITH PRODUCT MIX &
50 TPD SO2 PLANT Document No:-
M/s SEYA INDUSTRIES LTD.
SITE:- TARAPUR, MAHARASHTRA Rev
Document Title :
FFIL JOB NO:- 201712 Date
Provided thickness of the base plate = 75 mm > 73 mm Hence safe