You are on page 1of 2

Product Data Sheet

VERSILINE TL-91 S

VERSILINE TL-91 S: BASE 423V5 : CURING AGENT 927VC

Description: VERSILINE TL-91 S is a 100% solids high performance novolac epoxy lining with excellent
chemical resistance to a wide range of chemicals and solvents. TL-91 S is designed to be a
single coat application with rapid cure, allowing for a vessel to be returned to service in as little
as 36 hours.

Recommended use: As a lining system for crude oil up to 200⁰F (93⁰C), MTBE, produced water, alcohols, aromatic
and aliphatic solvents, aviation fuels, gasoline blends, select acidic and caustic chemicals.

Refer to Versiline Chemical Resistance guide or Contact your Hempel Representative for
specific cargo and service conditions.

Availability: Not included in Group Assortment. Availability subject to special agreement.

PHYSICAL CONSTANTS:

Shade nos / Colors: 16500* / Grey


Volume solids, %: 100
Theoretical spreading rate: 2 m²/litre [80.2 sq.ft/US gallon] - 500 micron/20 mils
Flash point: >100°C [212°F]
Specific gravity: 1.3 kg/litre [10.6 lbs/US gallon]
Dry to touch: 5 hours at 25°C/77°F
Fully cured: 24 hours at 25°C/77°F
VOC content: 16 g/litre [0.1 lbs/US gallon]
Shelf life: 1 year [25°C/77°F] from time of production
*Other shades according to specification.
The physical constants stated are nominal data according to approved formulas.

APPLICATION DETAILS:

Version, mixed product VERSILINE TL-91 S


Mixing ratio: BASE 423V5 : CURING AGENT 927VC
4 : 1 by volume
Application method: Heated plural component spray Brush (touch-up)
Thinner (max.vol.): Do not dilute
Pot life: 20-25 minutes at 25°C/77°F
Nozzle orifice: 0.023” - 0.027”
Nozzle pressure: 193-241 bar [2800-3500 psi]
(Airless spray data and amount of thinning are indicative and subject to adjustment depending
on ambient conditions and equipment set-up)
Cleaning of tools: Methyl Ethyl Ketone or Methyl Isobutyl Ketone
Indicated film thickness, dry: 500 micron per coat [20 mils per coat]
Indicated film thickness, wet: 500 micron per coat [20 mils per coat]
Overcoat interval: If overcoating/touch-up is required, contact HEMPEL

Safety: Handle with care. Before and during use, observe all safety labels on packaging and
paint containers, consult Hempel Material Safety Data Sheets and follow all local
or national safety regulations.

Issued: April 2016 Page: 1/2


Product Data Sheet
VERSILINE TL-91 S

SURFACE PREPARATION: Steel: Remove oil and grease etc. thoroughly with suitable detergent. Remove salts and
other contaminants by high pressure fresh water cleaning. Dry abrasive blasting to Sa 3
(ISO 8501-1) corresponding to SSPC-SP 5/NACE No.1 with a dense, angular surface profile
of Rz 75-100 micron/3-4 mils corresponding to ISO Comparator Medium (G), Keane-Tator
Comparator 3.0 to 4.5 G/S or Rugotest No. 3 BN 10a-b. After blasting, clean the surface
carefully from abrasives and dust.

All pitting, scratches, gouges, and other defects may be repaired either by welding or by filling
with VERSILINE CP-83 MP that are compatible with TL-91 S and suitable for the intended
service conditions.

Concrete: According to specification

APPLICATION CONDITIONS: Apply only on a dry and clean surface with a temperature above the dew point to avoid
condensation. 24 hours prior to application store the components (base and curing agent)
at 25°C-30°C/77°F-85°F to facilitate handling and spraying. Use only where application and
curing can proceed at temperatures above: 1.7°C/35°F*. Maximum relative humidity: 80%. In
confined spaces provide adequate ventilation during application and drying.

PRECEDING COAT: For Steel: VERSILINE TL-91 S or VERSILINE CP-83 MP


For Concrete: VERSILINE PRIMER 75 S

SUBSEQUENT COAT: None or VERSILINE TL-91 S

REMARKS:

Heated plural component spray: For application using heated plural component airless spray equipment, the base (423V5)
should be heated to 120°F (49°C) and curing agent (927VC) should be heated to 80°F (27°C).
Heating to higher temperature will have a negative effect on the overall application and
performance properties.

Film thicknesses: May be specified in other film thicknesses than indicated depending on purpose and area of
use. This will alter spreading rate and may influence drying time and overcoating interval.
Normal range dry film thickness is 500-750 micron / 20-30 mils.

*At lower temperatures close to 1.7°C/35°F, it is important not to exceed a dry film thickness
of 500 micron/20 mils.

Note: VERSILINE TL-91 S is for professional use only.

Issued by: HEMPEL USA Inc. – 423VC16500

This Product Data Sheet supersedes those previously issued.


For explanations, definitions and scope, see “Explanatory Notes” available on hempel.com. Data, specifications, directions and recommendations given in this data sheet
represent only test results or experience obtained under controlled or specially defined circumstances. Their accuracy, completeness or appropriateness under the actual
conditions of any intended use of the Products herein must be determined exclusively by the Buyer and/or User.
The Products are supplied and all technical assistance is given subject to Hempel's general conditions of sales, delivery and service, unless otherwise expressly agreed in
writing. The Manufacturer and Seller disclaim, and Buyer and/or User waive all claims involving, any liability, including but not limited to negligence, except as expressed
in said general conditions for all results, injury or direct or consequential losses or damages arising from the use of the Products as recommended above, on the overleaf
or otherwise. Product data are subject to change without notice and become void five years from the date of issue.

Issued: April 2016 Page: 2/2