You are on page 1of 2

Technical Data S ummary

GyroTrak

The Baker Hughes GyroTrak™ service System Performance


provides an MWD based North seeking Gyro GyroTrak service is an add-on to the
tool for applications where magnetic OnTrak™ and NaviTrak™ directional survey
interference dictates gyroscopic instruments services. Operators can choose to transmit
for directional surveying and BHA orientation. data from both sensor packages - offering
The GyroTrak service incorporates and data from two discrete survey packages
utilizes different types of Gyro sensors to (separated by a minimum of 15 ft (4.8 m)) and
provide a comprehensive service capable of facilitating better turn and build rate estimates.
operating in most conditions and with the wide The MWD-based GyroTrak service offers
range of BHI tools and services. significant survey time savings over
conventional wireline systems. The modularity
There are different challenging applications of the GyroTrak service allows it to be offered
where the GyroTrak service is required: in multiple configurations.
 collision avoidance in conditions of nearby
well casing interference The gyroscopes utilized in GyroTrak service
 kickoff below a casing shoe can withstand the drilling environment while
 whipstock orientation and window milling maintaining its calibrated accuracy. Using
 relief-well drilling advanced bias and temperature modelling, the
 drilling in formations where natural magnetic GyroTrak MWD service can provide azimuth,
interference exists inclination, highside toolface, gyro toolface, G-
total and earth rate, to be utilized in surveying.

GyroTrak

Features Benefits
Real-time orientation in a high magnetic
Utilization of the gyroscopes
interference environment
Reduced nonproductive time by elimination of
While drilling gyroscopic service
wireline rig up and run time
Reduction or elimination of non-magnetic
spacing, between survey sensors and Closer to the bit directional measurements
magnetic-metal components
No need for wireline gyroscopes run Reduced HS&E risk

©2014-2014 Baker Hughes Incorporated. All rights reserved.


GTK-70-01-001 Rev. A
Technical Data S ummary

GyroTrak

NaviTrak with GyroTrak Service OnTrak with GyroTrak Service


General Tool Specifications
US Units SI Units US Units SI Units
Hole size range 3⅞ in. to 17½ in. 98.4 mm to 444.5 mm 10⅝ in. to 26 in. 251 mm to 669 mm
3⅛ 79.4 mm — —
4¾ 120.7 mm — —
Nominal tool OD 6¾ 171.5 mm — —
8¼ 209.6 mm 8¼ 209.6 mm
9½ 241.3 mm 9½ 241.3 mm
20 ft to 33 ft 6.10 m to 10.10 m
Length 32 ft 9.75 m
(Collar dependent, modular or standard)
Weight
3⅛ 1,920 lb 700 kg — —
4¾ 2,450 lb 1,110 kg — —
6¾ 2,920 lb 1,325 kg — —
8¼ 3,520 lb 1,600 kg 1,900 lb to 5,000 lb 862 kg to 2,268 kg
9½ 5,415 lb 2,021 kg 2,700 lb to 6,600 lb 1,225 kg to 2,994 kg
Connections
3⅛ Up: 3-in. CDP Box Down: 3-in. CDP Box — —
4¾ Up: 3½-in. IF Box Down: 3½-in. IF Box — —
6¾ Up: 4½-in. IF Box Down: 4½-in. IF Box — —
w/ Stop Sub: Up/Down: 6⅝-in. Reg. Box/Pin
8¼ Up: 6⅝-in. Reg. Box Down: 6⅝-in. Reg. Box
w/o Stop Sub: Baker Hughes Modular M30 internal connections1)
w/ Stop Sub: Up/Down: 7⅝-in. Reg. Box/Pin
9½ Up: 7⅝-in. Reg. Box Down: 7⅝-in. Reg. Box
w/o Stop Sub: Baker Hughes Modular M30 internal connections1)
Power source 10 cell lithium ion battery Turbine alternator/ 10 cell lithium ion battery
Survey accuracy is quantified by an ISCWSA format error model. The model reflects the sensitivity of tool performance to the geographic
Accuracy
location, inclination and azimuth of each survey station.

NaviTrak with GyroTrak Service OnTrak with GyroTrak Service


Operating Specifications and Limits
US Units SI Units US Units SI Units
Maximum temperature
Operating 32°F to 239°F 0°C to 115°C 32°F to 302°F 0°C to 150°C
Survival -40°F to 257°F -40°C to 125°C -40°F to 302°F -40°C to 150°C
Memory 8 MB for quality Control (QC) purposes for quality control (QC) purposes only
Operating inclination 25° 25°, 30˚, 40°, 70˚ and 90° (tool version dependent)

NaviTrak with GyroTrak Service OnTrak with GyroTrak Service


Sensor Specifications
US Units SI Units US Units SI Units
Varies based on tool configuration and number of batteries used.
Varies based on tool configuration and number of batteries used.
Operating time, min. circulation hours Temp. <70°C ≅ 100 hrs. with 100 surveys
Estimated flow off hours per battery is 150 hours.
Temp. >70°C ≅ 45 hrs.
Pressure rating 20,000 psi 1,380 bar 20,000 psi 1,380 bar
Calculated output Azimuth, inclination, highside toolface, gyro toolface, GT, earth rate and gyro temperature
Pressure rating 5–10 min. from start of survey to first transmitted word, depending on accuracy requirements
1) To connect to Baker Hughes components only.

Drilling & Evaluation Although the information contained herein is believed to be accurate, no other representations are made concerning the information. Under no circumstances shall Baker Hughes be liable for any incorrect or incomplete
2001 Rankin Road information. All technical specifications and commercial information concerning the product and/or services described herein may be changed at any time without further notice. Refer to Supplemental Technical Specifications
Houston, Texas 77073 (TDS-20-60-0000-00) for further environmental specific specifications and information on the application, operation, and handling of Baker Hughes tools. Technical Data Summaries are controlled documents and can only be
Phone: +1 713-625-4200 released through the BHOS – Global Ops/AMO Documentation Group.
www.bakerhughes.com GTK-70-01-001