1. Working Principle Non invasive type 3D Laser technology to be used
for physical calibration of the tanks at site.
Procedure shall not require complete empting of
tanks, degassing etc.
Should be able to calibrate during normal working
operation of Retail Outlet without any interference
of the RO operation.
2. Accuracy ± 0.5% or better for entire tank
3. Nozzle size required Min. 50 mm
for entry of measuring
probe
4. Calibration Chart Least count of 1.0 mm or better
Strapping chart to be provided.
The calibration charts are to be incorporated in the
system.
5. Diameter of tank for Upto 3.5 meters
calibration
6. Level of product for 5% to 20% of tank capacity
calibration
7. Standard ambient (-) 50C to (+) 600C.
temperature
8. Approvals required PESO, W&M, ATEX, OIML