Professional Documents
Culture Documents
Hydrology
Catchment area(intake site) 36Km2
Mean annual precipitation 2911.45mm
Design flood at intake site 4.297 cumecs
Design discharge 1.56m3/s
Power plant
Types of power generation Run of type(ROR)
Installed capacity 3.36 MW
Gross head 262.48 m
Net head 258.74 m
Wet energy 4.81GWh
Dry energy 14.91 GWh
Diversion structure
Type of weir Broad crested weir
Length of weir 16.9 m
Height of weir 2.6 m
Width of under sluice 2.5m
Spill way crest level 1582.6 m
Guide wall level 1585.35m
Intake
Intake type Submerge side Orifice
Intake opening(L*B) 1.8m*1.2m
Intake sill level 1581m
Intake canal
Canal type Open
Shape Rectangle
Length 2m
Width 1.8 m
Height 2.78 m
Slope 1 in 3433
Gravel Trap
Length 5m
Width 2.3m
Height 3m
Longitudinal Slope 1 in50
Inlet transition 1.25 m
Outlet Transition 1.1 m
Approach canal
Canal type Open
Shape Rectangle
Length 50.8 m
Width 1.2 m
Height 1.95 m
Slope 1 in 1000
Settling Basin
Length 26 m
Width 4m
Height 4.2 m
Longitudinal Slope 1in 50
Inlet Transition 7m
Outlet Transition 3m
Headrace canal
Forebay
Length 10.8 m
Width 3m
Height 5.3 m
Longitudinal Slope 1 in 50
Inlet Transition Length 2.85 m
Penstock
Type of material mild Steel
Type of flow Pressurized
Length 474 m
Internal diameter 80 cm
Thickness 14 mm
Bifurcation penstock
Type of material mild Steel
Type of flow Pressurized
Internal diameter 56 cm
Thickness 11 mm
Power house
Type surface
Dimension 18.4m*10.27m*11.11m
Turbine
Type of turbine Pelton
No of turbine 2 no.s
Turbine output 1.68 MW(Each)
Generator
No of units 2
Type Synchronous, 3 phase verticalaxis
Transformer
No of units 1
Type Step-up
Economic factor