Building Element As per submitted design Remarks

GENERAL

Building Structure Type Frame Structure


Number of storey applied for permit (in Nos.) 3
Number of storeys considered in Structural design (in 3
Nos.)
No
Provision for further extension considered or not

ETABS
If Computer Aided Design (CAD) is used, please state the
name of the Software package

8.61
Total height (h) of structure with extension (in m)

NBC 101-1994 MATERIALS SPECIFICATIONS

Materials to be used in structure (tick the listed materials


RCC (Reinforcement Bar)
that will be used in structural element

Stone Masonry
Structural Aluminium
Brick Masonry
Timber
Structural Steel
NBC 102-1994 UNIT WEIGHT OF MATERIALS
Specify the design unit weight of materials: RCC (in 25
kN/m3)
Specify the design unit weight of materials: Brick Masonry 19.2
(in kN/m3)
NBC 103-1994 OCCUPANCY LOAD (IMPOSED LOAD)
Occupancy Load (Uniformly Distributed load in kN/m2) for 2
Rooms and Kitchen
Occupancy Load (Uniformly Distributed load in KN/m2) for 3
Corridors, Staircase, Store
Occupancy Load (Uniformly Distributed load in KN/m2) for 3
Balcony
NBC 104-1994 WIND LOAD
2
Wind Zone

Basic wind speed (m/s) 47


NBC 105-1994 SEISMIC DESIGN OF BUILDINGS IN NEPAL
Sei s mi c Coeffi ci ent Approach
Method adopted for eathquake resistant design

Adopted Code for Seismic Design IS:1893-2002


Subsoil category Type III (Soft)
Seismic Weight (W) (in kN) 2177.357
Fundamental Time Period of the building along X (Tx) (in 0.37
Seconds)
Fundamental Time Period of the building along Y (Ty) (in 0.37
Seconds)
Seismic zoning factor (Z) 0.36
Importance Factor (I) 1
Response reduction factor (R) 5
Spectral acceleration coefficient Along X (Sa/g) 2.5
0.09
Design Horizontal Seismic Coefficient Along X (Ah)

Spectral acceleration coefficient Along Y (Sa/g) 2.5


0.09
Design Horizontal Seismic Coefficient Along Y (Ah)

Base Shear(VB) for Seismic Coefficient Along X 195.962


Base Shear(VB) for Seismic Coefficient Along Y 195.962
Maximum Inter-Storey Drift 0.001
Corresponding Storey height for Maximum Inter-Storey 2.87
Drift (h)
Maximum Inter-Storey Drift Ratio 0.003
NBC 106-1994 SNOW LOAD
Snowfall type or condition No s nowfal l
NBC 107-1994 PROVISIONAL RECOMMENDATION ON FIRE
SAFETY
Have you considered fire safety requirement? No
NBC 108-1994 SITE CONSIDERATION FOR SEISMIC HAZARDS
No
Whether distance of construction site from toe/beginning
of downward slope is within 50m?

Whether distance of construction site from river bank is No


within 50m?
Availability of soil test report No
NBC 114-1994 CONSTRUCTION SAFETY
Yes
Are you sure that all safety measures will be fulfilled in the
construction site as per this code?

Safety wares use Safety hard hat


Safety goggles
Safety boots
Safety belts
First aid facility
STRUCTURAL DATA FOR FRAMED RCC STRUCTURE
NBC 110-1994 PLAIN AND REINFORCED CONCRETE
Concrete grade in structure M20
M25
M30
M35
Reinforcement Steel Grade Fe-500

Slab Design

Boundary Condition of Slab 2 Adjacent-Si de Conti nuous


Effective Thickness of Slab (d) (in mm) 108
Short Span of Critical Slab Panel (L) (in mm) 3580
Calculated short span to effective depth ratio (L/d) for 33
corresponding slab
26
Basic (L/d) ratio

2
Required modification factor for tension reinforcement

0.14
Required Tension Reinforcement (Ast) Percentage (%) for
short span bottom reinforcement
0.14
Provided Tension Reinforcement (Ast) Percentage (%) for
short span bottom reinforcement

2
Actual Modification factor for tension reinforcement

Check for Critical beam


Effective depth of beam (d) (in mm) 317
Critical span (L) (in mm) 4800
Support condition One Si de Conti nuous
Basic (L/d) ratio 23
15.14
Calculated Critical Span to effective depth ratio (L/d)

Check for Critical Column


Critical column length 2.87
Minimum size of column (in mm) x 305
305

Short column effect considered or not No

1
Minimum area of longitudinal reinforcement provided (%)

Design Philosophy Li mi t State method


Load Combinations (IS)
1:DL 1.5
1:LL 1.5
2:DL 1.2
2:LL 1.2
2:EQ 1.2
3:DL 1.5
3:EQ 1.5
4:DL 0.9
4:EQ 1.5
Yes
Whether sample design calculations of foundations,
columns, beams and slabs are submitted

FOUNDATION
Type of Foundations Isolated
Combined
Raft
PILE
Strap
Depth of foundation from ground level to the buttom of 1.54
footing (in m)
Sa ve Ca ncel