You are on page 1of 1

C4

C5

SPECIFICATION:
SERVICE ENTRANCE

C1 PB
MAIN PANEL BOARD 1. THE SUPPLY VOLTAGE SHALL BE 220 V, 1 PHASE , 2 WIRE 60 HZ
LIGHTS

LUMAINER LAMP
2. SERVICE ENTRANCE CONDUCTOR SHALL BE INSTALLED IN RIGID STEEL
POST LAMP CONDUIT OR EMT PIPE.
CONVENIENCE OUTLET
S1 SINGLE THUMBLER SWITCH GANG
3. THE MINIMUM WIRE TO BE USED SHALL 3.5 MM² TW CM. WIRE.
S2 DOUBLE THUMBLER SWITCH GANG

LIGHTING HOMERUN
POWER HOMERUN 4. ALL ELECTRICAL INSTALLATION SHALL BE DONE IN ACCORDANCE WITH
SWITCH OMERUN
LATEST EDITION OF PHIL. ELECTRICAL CODE.
C2 STAGE
5. ELECTRICAL WORK MUST BE UNDER THE DIRECT SUPERVISION OD DULY
C3 LICENSED ENGINEER OR A REGISTERED MASTER ELECTRICIAN.

M 220 V 1 Ø .2 - WIRE, 60HZ


service entrance
2 - / 4 MM² THW IN 25MM Ø RSC PIPE

BASKETBALL 2 - / 4 MM² THW IN 25MM Ø RSC PIPE


COURT

C1 40AT 20AT C2

C3 20AT 20AT
C4
C6

C5 20AT 20AT
C6

1 - 8 MM² TW CU. GROUND WIRE

1 GROUND FLOOR ELECTRICAL PLAN HALL WAY 2 SCHEMATIC DIAGRAM 3 VICINTY MAP
E1 SCALE 1:250 METERS
E1 SCALE NTS
E1 SCALE NTS

PRC NO.
DRAWNED BY: PROJECT TITLE: APPROVED BY: SPECIFICATIONS
TIN NO.
PROPOSED ILIGAN CAPITOL COLLEGE GYMNASIUM GROUND FLOOR ELECTRICAL PLAN
PTR NO.

DATE ISSUED
LOCATION: SCHEMATIC DIAGRAM
1
PLACE ISSUED
BRGY MAHAYAHAY , ILIGAN CITY LEGEND AND ELECTRICAL SPECIFICATION E2
ELECTRICAL ENGINEER OWNER: MADAME ROSALINDA R. DELESTE OWNER'S APPROVAL VICINTY MAP