You are on page 1of 4

HTR FR PVC

Insulated Cable

Cable Catalogue 2012


Single Core HTR FR PVC Insulated Copper Conductor (Unsheathed), Industrial Cables, 1100 Voltage Grade

Skin color PVC


Natural PVC
Multistrand copper conductor

Current Carrying Capacity 2


Cables Single Phase Max.
Nominal Cross Number/Nom. Thickness
Approx. Overall Unenclosed Conductor
Basic Code Sectional area Dia of cond. of Insulation
Diameter Conduit/ clipped directly Resistance per
of conductor strands (Nom)
Trunking to a surface or KM at 20º C
on cable trays
HTR FR sq. mm. mm mm mm Amps Amps Ohms
WSFFDN…A1X50 0.5 16/0.2 0.6 2.1 4 4 39.00
WSFFDN…A1X75 0.75 24/0.2 0.6 2.3 8 8 26.00
WSFFDN…A11X0 1.0 14/0.3 0.7 2.7 12 13 18.10
WSFFDN…A11X5 1.5 22/0.3 0.7 3.0 14 18 12.10
WSFFDN…A12X5 2.5 36/0.3 0.8 3.6 20 24 7.41
WSFFDN…A14X0 4.0 56/0.3 0.8 4.1 26 32 4.95
WSFFDN…A16X0 6.0 84/0.3 0.8 4.6 34 41 3.30

...Fill the colour code i.e. B = Blue ...


B

Note : 90 metres length in carton packaging & 180 metres project lengths in polywrap packaging.
HTR FR available in 90 metres packing & 180 metres with type A PVC.
** Conductor Shall be class-II for 1.0, 1.5 & 2.5 Sqmm & for other size shall be of class V as per IS:8130
*The number and diameter of conductor strands are for reference only. Conductor resistance as per IS:8130 is the governing criteria.

Single Core HTR FR PVC Insulated Copper Conductor (Unsheathed), Flexible Industrial Cables, 1100 Voltage Grade

Skin color PVC


Natural PVC
Multistrand flexible copper conductor

Current Carrying Capacity 2 Max.


Nominal Cross Number/Nom. Thickness Cables Single Phase
Approx. Overall Conductor
Basic Code Sectional area Dia of cond. of Insulation
Diameter Unenclosed clipped directly to a Resistance per
of conductor strands (Nom)
surface or on cable trays KM at 20º C

HTR FR sq. mm. mm mm mm Amps Ohms


WSFFDN…B1010 10 80/0.4 1.0 6.1 51 1.91
WSFFDN…B1016 16 126/0.4 1.0 7.0 68 1.21
WSFFDN…B1025 25 196/0.4 1.2 8.6 88 0.780
WSFFDN…B1035 35 276/0.4 1.2 9.7 112 0.554
WSFFDN…B1050 50 396/0.4 1.4 11.5 152 0.386

...Fill the colour code i.e. B = Blue ...


B

Note : Conductor as per class V of IS:8130 of IS:694, Standard Packing length 100 metres and bigger packing on request.
*The number and diameter of conductor strands are for reference only. Conductor resistance as per IS:8130 is the governing criteria.

Construction
Conductor : Plain annealed copper conductor as per IS:8130
Insulation : Primary - Natural PVC with HTR FR property
Secondary - Skin color coated PVC with HTR FR property
(25 sq mm and above are provided with unicolour insulation only)
Colour : Red/Yellow/Blue/Black/Green
Any other colour on specific request can also be supplied.
Multicore Round HTR FR PVC Insulated Copper Conductor and PVC Sheathed Flexible Industrial Cables, 1100 Voltage Grade

Conductor
Conductor
Insulation Insulation
Sheath Sheath

Nominal Thickness of Voltage Drop/


Nominal Appx. Overall Diameter
Number Sheath Amp/Meter
Cross Thickness Current Max. Conductor
Nom. dia DC or
Sectional of Insula- Rating 3 Resistance Per KM
Basic Code of cond.
Area of tion (Nom) Two Three Four Two Three Four AC Single
Phase at 20ºC
strands* Core Core Core Core Core Core Phase
Conductor AC
AC
sq. m,m mm mm mm mm mm mm mm mm Amps mV mV Ohms
WSMFDSKB_X50 0.5 16/0.20 0.6 0.9 0.9 0.9 6.2 6.5 7.0 4 83 72 39.0
WSMFDSKB_X75 0.75 24/0.20 0.6 0.9 0.9 0.9 6.6 6.9 7.5 8 56 48 26.0
WSMFDSKB_1X0** 1.0 32/0.20 0.6 0.9 0.9 0.9 6.9 7.3 7.9 12 43 37 19.5
WSMFDSKB_1X5** 1.5 30/0.25 0.6 0.9 0.9 1.0 7.4 7.8 8.7 14 31 26 13.3
WSMFDSKB_2X5** 2.5 50/0.25 0.7 1.0 1.0 1.0 8.8 9.4 10.2 20 18 16 7.98
WSMFDSKB_4X0 4.0 56/0.30 0.8 1.0 1.0 1.0 10.2 10.9 11.9 26 11 9.6 4.95

Note : Available in 100 metres length with black outer sheath & in bigger packing on request. Any colour on specific request can be supplied, in economical run.
*The number and diameter of conductor strands are for reference only. Conductor resistance as per IS:8130 is the governing criteria.
**Conductor shall be of Class-V as per IS:8130

Co-Axial TV Cables

Sheeth PE Insulation

Braid Copper
conductor
AI. Mylar
tape

Application : Used in cable TV operations, Computer net-working etc.


Construction : Solid annealed bare copper conductor, gas injected foam polythene insulated and alloy braided with Petroleum jelly flooded, & Overall PVC
sheathed.

Technical Data
Type Standard Range Flame Retardant HTR FR Type Standard Range Flame Retardant HTR FR
Size RG-6 Inner Conductor Solid Bare Copper
Conductor Solid Copper Nom. diameter (mm) 1.02
Insulation Gas Injected Physical Foamed Polyethylene Dielectric Foam PE
Outer Conductor Braided with Aluminium Alloy Wire Nom. diameter (mm) 4.57
Outer Jacket UV Resistant Black PVC Jacket Outer Conductor - First Bonded AL Tape
Progressive Sequential Length marketing on Every Outer Conductor - second AL Braid
Marking
Meter Nom. Coverage (%) 60
Max. Resistance 2.13 (W/km) @ 20°C (inner conductor) Jacket PVC (Black)
Nom. Impedance 75 (W) Nom. diameter (mm) 7.00
Loop Resistance 2.78 (W/km) @ 20°C (inner conductor) Nom Velocity Ratio (%) 85
Telephone Switch Board Cables
Application : Cables used for Indoor Telephones, Telephone Exchanges, Satellite Telecommunication Systems, Industrial Plant Communication systems,
EPBAX system, Closed Circuit Security Systems, In-House Telephone wiring and various other equipments involving telephones.
Standard : Cables are generally made as per TEC Specification No. G/WIE-06/02 or as per customer specification.
Construction : Solid annealed tinned/bare copper conductor, PVC insulated cores suitably colour coded for distinct identification, twisted to form pairs laid
up, PVC sheathed. Armoured Cables are provided with Galvanised steel wire/strip armouring and then sheathed again with PVC

Design / material Options


Conductor : Tinned copper/Bare copper
Insulation : PVC/Polythelene
Shielding : Over all shielded / Individual pair shielded and over all shielded with polyester
backed aluminium tape or fine copper wire braid (Manufactured against
Armour
customer’s orders only for economical runs.) Conductor
Sheathing : PVCFR/FRLSH/Polythelene Insulation Inner sheath
Conductor size Cable : 0.5 mm Twisted
Bedding tape
pair
Configuration : 2p, 3p, 4p, 5p
Note: Supplied in 90 metres length carton except 3 pairs and above polywrap coils. Outer sheath
Filler

Salient Features for Telephone Cable


• Hard grade PVC insulation is used for long life and stable properties of cables, • Staggered lays of twisted pairs are used to ensure minimum cross talk.
• Sizing and processing of conductor and insulated cores is done in precisely controlled manner on automatic modern machines to have optimum values
of capacitance, capacitance unbalance, image and cross talk attenuation and characteristic impendence, • Shielding is done to protect from outside /
inter pair interference as per specific needs.

High Temperature Resistant (HTR) Flame Retardant Cables


Electrical wires are used as electrical paths for Industrial and household power applications. In general, excessive voltage drops/ fluctuation in service
line result in lower voltage at the receiving end. Due to this lower voltage, the current drawn and the current passing through the electric wires are higher
than normal which results in high temperature rise in the conductor. Ordinary wires cannot sustain such system abnormalities and may lead to risks of
short circuit and serious fire hazards.
STANDARD ( HTR ) FR wires have specially been developed to operate under such operational conditions. They incorporate special technology which is
rated for 10 % higher current carrying capacity and can withstand high temperature rise even during the worst of overloading conditions.

Comparative technical features are given in the details below


S.No Feature Normal FR Range Standard (HTR)
1 Insulation Material FR PVC Special PVC
2 Insulation property Good Very Good
3 Temperature Rating 70°C 85°C
4 Thermal stability 80 100
5 Flame Retardancy Very Good Excellent
6 Temperature Index >250°C >300°C
7 Abrasion Resistance During Installation Good Very Good
8 Life of Product Normal 20% more than Normal
9 Rated current Normal 10% higher than Normal
10 Leakage current at operating temp. Normal 10% less than Normal

Regional & Branch Offices :


NORTH - REGIONAL OFFICE: Corporate Office: QRG Towers, 2D, Sector-126, Expressway, Noida-201304, Tel: 0120-4771000, Fax: 0120-4772000, Delhi : Tel: 011-
47676700, 23888200, Fax: 011-47676750, 23888250, Chandigarh: Tel: 0172 4232400-401, Fax: 0172-4232403, Dehradun: Tel: 0135-6670202, Fax: 0135-6670203,
Haryana: Tel: 91-120 2477848 / 853, Fax: 0120-2583904, Noida: Tel: 0120-3055609/ 3055610, Fax: 0120-3055611, Ludhiana: Tel: 0161-4676001 / 6024, Fax:
0161-46766007, Jammu: Tel: 0191-2490424, Fax: 0191-2490405, Jaipur: Tel: 0141-3988210, Fax: 0141-2389024, Kanpur: Tel: Airtel: 09935533751 /52/53, 0512-
2690128/129/130, Fax: 0512-2692800, Lucknow: 0522-2201032,2200938
EAST - REGIONAL OFFICE: Kolkata: ICC Tower, 5th Floor, 4 India Exchange Place, Kolkata-700001, Tel: 033-40129851/52, Fax: 033-40127339, Bhubaneshwar:
Tel: 0674-2598104, 2598105, 2598106, Fax: 0674-2598107, Guwahati: Tel: 0361-2134521, 2458923, Fax: 0361-2460355, Siliguri: Tel: 0353-2525907-3290402 (RIM),
Jamshedpur: Tel: 0657-6542492, 09234369436, Patna: Tel: 0612-3244218, 2655519, Telefax: 0612-2655518
WEST - REGIONAL OFFICE: Mumbai: 302, Boston House, 3rd Floor Suren Road, CTS No. 260/261, Andheri (E) Mumbai-400093, Tel: 022-67298600-603, Ahmedabad:
WIR/ZSCMC00001/DEC12

Tel: 079-40061111, 40060738-740, Fax: 079-40060741, Indore: Tel: 0731-2572340-41, 4009998 (Airtel), Fax: 0731-2551626, Rajkot: Tel: 0281-3013289/3013290,
Nagpur: Tel: 0712-2224132, 2222692, 2222029, Pune: Tel: 020-64016413/14, Raipur: Tel: 0771-4243400 / 01, Telefax: 0771-4243402, Surat: Telefax: 0261-2350137
SOUTH - REGIONAL OFFICE: Chennai: Block – 1, A & D Wing, Shakthi Towers, 7th Floor, 766, Anna Salai, Chennai-600002, Tel: 044-28526941-44, Fax: 044-28524326,
Bangalore: Tel: 080-49075000, Fax: 080-25582663, Coimbatore: Telefax: 0422-2305767, 2306199, 2305199, Hyderabad: Tel: 040-27533372, 27533355, 27533632,
66320407/0408/6401/6402, Fax: 040-27533211, Kochi: Tel: 0484-4099000, 2393165, 2393068, Fax: 0484-2393170, Vishakapatnam: Tel: 0891-6514339, Fax: 0891-
2522547

Representative Offices :
• Goa • Solapur • Gwalior • Jabalpur • Hubli • Davanagere • Gulbarga • Mysore • Trichy • Kathmandu • Sambalpur • Jalandhar • Bhopal • Calicut
• Madurai • Trivandrum • Vijayawada

HAVELLS INDIA LIMITED


Corporate Office: QRG Towers, 2D, Sector -126, Expressway, Noida - 201 304 (UP),
Ph. +91-120-4771000, India E-mail: standard.ho@havells.com
Consumer Care No.: 1800 11 0303 (Toll Free), 011-41 66 0303 (Landline), 1800 103 1313 (All connections)
Registered Office: 1/7, Ram Kishore Road, Civil Lines, Delhi - 110054
Visit us at : www.sel.co.in

You might also like