Palabras clave: Avícola, reactor anaerobio, reactor aerobio, demando bioquímica de oxígeno,
demanda química de oxígeno.
Abstract
Poultry industry is one of the branches of the animal production of greater importance from the
exploitation of two of its basic slopes; production of meat and egg, in production line generate
wastewater with a high organic load, grease and suspended solids, such as the “Finca Avícola
Fincavic S.A “generating sewage with a COD of 1136.46 mg/L, BOD 5 of 915 mg/L and SST of
443.67 mg/L, parameters that leave outside the permissible limits for discharge to the public
sewer system of the Ecuadorian regulations. This is why the objective of this study is the design
of a wastewater treatment plant from “Finca Avícola Fincavic S.A”, located in Sangolquí-
Pichincha. The plant has an activated sludge treatment composed of a preliminary treatment of
grids, primary settler, aerobic reactor and secondary settle, the sludge of both settlers are
stabilized by a digestor of low load and drying bed. The effluent after passing through the different
stages of treatment has a COD of 116.124 mg / L, BOD 5 of 119.9 mg / L and SST of 135.60 mg/L,
values that are within the ecuadorian norm, complying with the limits for discharge to Public
sewage system are COD of 500mg /L, BOD5 of 250mg /L y SST of 220 mg /L.
Keywords: Poultry, anaerobic reactor, aerobic reactor, biochemical oxygen demand, chemical
oxygen demand
2. MATERIALES Y MÉTODOS
La evaluación de los parámetros DBO5 y DQO en las aguas residuales tomadas de la “Finca
Avícola Fincavic S.A” se realizó en los laboratorios del Centro de Investigaciones Científicas
(CEINCI) de la Universidad de las Fuerzas Armadas-ESPE. El caudal máximo, mínimo y
promedio, temperatura y pH se determinaron en el momento de la toma de la muestra, otros
parámetros detallados en la Tabla 1 se obtuvieron mediante búsqueda bibliográfica, los valores
se compararon con el Texto Unificado de Legislación Secundaria del ministerio del ambiente
(TULAS) con el fin de identificar los parámetros sobre los cuales se tendría que trabajar para el
diseño de la planta de tratamiento.
La Finca Avícola Fincavic S.A cuenta con 5 galpones distribuidas en 6 hectáreas con una
capacidad máxima de 15000 aves en fase producción, de acuerdo con Fincavic S.A (2016) la
tasa de crecimiento de producción anual para la empresa avícola es de 3.5 % y el caudal máximo
dura alrededor de 4 horas, tomando en consideración esta información la proyección del caudal
se realizó en base al caudal máximo. El caudal proyectado para los 15 años es 183,43 mL/s. En
el Gráfico 1 se observa la curva de crecimiento del caudal proyectado para los 15 años.
100
y = 4.912x + 106.67
0 R² = 0.9951
0 2 4 6 8 10 12 14 16
Tiempo( años)
Gráfico 1: Proyección del caudal máximo para 15 años con una tasa de crecimiento en producción del 3.5%
anual.
Parámetros seleccionados en el diseño de la planta de tratamiento
Los parámetros obtenidos en el análisis de las aguas residuales de la Finca Avícola Fincavic S.A
fueron comparados con el TULAS, determinando los valores que no cumplían con la normativa
ecuatoriana para la descarga al sistema de alcantarillado público, esto permitió identificar los
datos (Tabla 2) con los que se trabajaría en el diseño de la planta de tratamiento para la Finca
Avícola Fincavic S.A
Tratamiento Preliminar:
Rejillas de desbaste
Los tratamientos preliminares son destinados a preparar las aguas residuales para que
puedan recibir un tratamiento posterior, sin que ocasionen problemas a los equipos mecánicos
y causar depósitos permanentes en tanques cuya presencia pueda provocar problemas de
mantenimiento y funcionamiento de las operaciones; para minimizar algunos efectos
negativos como grandes variaciones de caudal y descomposición y la presencia de materiales
flotantes (Cajas, 2014). El primer paso en el tratamiento del agua residual consiste en la
separación de los sólidos gruesos. El procedimiento más habitual se basa en hacer pasar el agua
residual bruta a través de rejas de barras (Hammeken & Romero, 2005).
El diseño del canal artificial se define en términos de la profundidad de flujo y de las dimensiones
de la sección. Generalmente se diseñan con secciones de figuras geométricas regulares siendo
así rectangulares, trapezoidales, triangulares, entre otros. Se debe de tener en cuenta algunos
elementos geométricos y factores como: tipo de material, coeficiente de rugosidad, velocidad
máxima y mínima permitida y la pendiente del canal (Valencia, 2013).
Tratamiento Primario
Sedimentador primario
Luego de la rejilla de limpieza manual, se colocó un sedimentador primario circular, y no uno
rectangular, porque estos últimos pueden provocar puntos muertos de distribución de la carga
de sólidos (Saldes y Alkalay lowitt, 2004).
Esta unidad cuenta con coagulación y floculación (poliacrilato sódico), con una pendiente de
fondo para sostener en la parte superior el agua residual y en la parte inferior retener los lodos
producto de la sedimentación por gravedad, permitiendo eliminar la mayor cantidad de sólidos y
materia orgánica que pudiera causar obstrucción de tuberías (Comisión Nacional del Agua,
2013). Además, el agua contará con flujo horizontal y se descargará a la tubería de salida por
medio del vertedero que rodea todo el diámetro del sedimentador.
Tratamiento Secundario
Sedimentador secundario
Después del reactor aerobio completamente mezclado se colocó un sedimentador secundario
cilíndrico (Bustos, 2012), el cual, es el responsable de la separación de sólidos suspendidos
restantes del agua tratada, para obtener un efluente de buena calidad.
Lechos de secado
Se utilizan para deshidratar lodo extendiendolo sobre una capa de arena de espesor 20 a 25 cm,
dejándolo secar. Una vez perdida la humedad, se puede utilizar como material de relleno o
fertilizante.
Un lecho de secado típico debe ser diseñado para retener en una o más secciones, el volumen
total de todo removido del digestor. Los elementos estructurales del lecho incluyen los muros
laterales, tuberías dedrenaje, capas de arena y grava (Villarroel, 2012).
Se recomienda utilizar como medios de drenaje capas de grava y de arena. La capa de grava
debe tener un espesor entre 200 y 460 mm y la capa de arena un espesor entre 250 y 460 mm.
Las partículas de grava deben presentar un diámetro entre 3 y 25 mm. El tamaño efectivo de los
granos de arena debe estar entre 0.3 y 0.75 mm (Maita, 2012).
3. RESULTADOS
Tratamiento Preliminar
Los parámetros de diseño calculados para el canal de ingreso del agua residual, con las
ecuaciones y parámetros propuestas por Metcalf & Eddy (1995) se indican en la Tabla 4.
El canal de llegada tiene como función recibir el agua residual que llega de la avícola. Con la
finalidad de que el flujo del agua sea constante dentro del canal se ha propuesto una pendiente
del 5% lo que define la velocidad del caudal máximo que es de 0,435 m/s. El valor de la velocidad
calculado está dentro de los parámetros estabecidos, ya que según Lozano-Rivas (2013) este
valor debe ser menor a 2.5 m/s.
Tratamiento Primario
De acuerdo con Crites & Tchobanoglous (2000), el tiempo de retención empleado para un
sedimentador primario seguido por tratamiento secundario se encuentra en el rango de 1,5 a 2,5
horas, se eligió un valor intermedio de 2 horas. A su vez, la tasa de carga superficial toma valores
entre 2 y 10 m3/m2-d (PAHO, 2005), en consecuencia se fijó un valor de 7 m3/m2-d. Los cálculos
del dimensionamiento se resumen en la Tabla 6.
Remoción de DBO
Área superficial (As) 2,264 m2 𝑇𝐷𝐻
Diámetro (D) 1,700 m 𝑅𝐷𝐵𝑂 = ∗ 100
0,018 ℎ + 0,020 𝑇𝐷𝐻
Profundidad (H) 0,583 m
Remoción de SST
Remoción de DBO 34,48 % 𝑇𝐷𝐻
𝑅𝑆𝑆𝑇 = ∗ 100
0,0075 + 0,014 𝑇𝐷𝐻
Remoción de SST 56,34 %
Remoción de DQO* 31,88 % Profundidad total
Profundidad total (Ht) 0,733 M 𝐻𝑡 = 𝐻 + D/2 * tg(p)
Diámetro total (Dt) 1,850 m
Diámetro hasta el vertedero
𝐷𝑡 = 𝐷 + Dv
Qu= ?
SSu = 12000mg/L
Balance de líquidos 𝑄𝑜 = 𝑄𝑒 − 𝑄𝑢
Balance de SS 𝑄𝑜𝑆𝑆𝑜 = 𝑄𝑒 𝑆𝑆𝑒 − 𝑄𝑢 𝑆𝑆𝑢
𝑄𝑜(𝑆𝑆𝑢 − 𝑆𝑆𝑜 )
𝑄𝑒 =
𝑆𝑆𝑢 − 𝑆𝑆𝑒
𝐿 𝐿
𝑄𝑒 = 15512,812 , 𝑄𝑢 = 335,538
𝑑 𝑑
Tratamiento secundario
Los valores asumidos y calculados para el diseño del reactor aerobio completamente mezclado
se resumen en la Tabla 7.
Para el reactor aerobio se utilizarán aireadores OXYSTAR de FUCHS, ya que son empleados
para introducir oxígeno en lagunas, tanques ecualizadores o reactores de lodos activados como
es nuestro caso. Además de proveer una aireación de burbuja fina, los aireadores también
proveen un buen flujo y mezcla de agua residuales en el reactor (FUCHS, 2014).
Con los datos obtenidos se determinó que utilizar un aireador OXYSTAR OS 3.0 con potencia
de 2.2 KW es suficiente para mantener los requerimientos de oxígeno en el reactor.
(𝑄 + 𝑄𝑤 + 𝑄𝑟 )
Caudal futuro máximo (Q) 15.848 m3/d Área total: 𝐴𝑇 =
Régimen de flujo (Rf) 16.3 m3/d- m2 𝑅𝑓
Caudal de lodos desalojados 0.408 m3/d Diámetro: 2 4∗𝐴
𝑇
(Qw) 𝐷=√
𝜋
Caudal de recirculación (Qr) 6.792 m3/d
Tiempo de retención 2 h 𝐷 2
hidráulico (TDH) Volumen: 𝑉 = 𝜋( ) 𝐻
2
Pendiente en el fondo (p) 10 °
Eficiencia de remoción de 30 % Carga del vertedero:
SST (E)
SST que ingresa al 193.71 mg/L 𝑄
clarificador (SSTo) 𝐶𝑣 =
𝜋𝐷
Diámetro desde la pared al 0.15 m Profundidad
vertedero (Dv)
Valores calculados 𝐻 = 𝑅𝑓 ∗ 𝑇𝐷𝐻
SST efluente
Área superficial (AT) 1.414 m2 𝐸
Diámetro del sedimentador 1.342 m 𝑆𝑆𝑇𝑒 = 𝑆𝑆𝑇𝑜 × (1 − )
100
(D) Profundidad total
Diámetro total (Dt) 1.492 m 𝐷
𝐻𝑡 = 𝐻 + ∗ tan(𝑝)
Volumen del sedimentador 0.874 m3 2
(V)
Profundidad (H) 0.5 m Diámetro hasta el vertedero
Profundidad total (Ht) 0.618 m 𝐷𝑡 = 𝐷 + 𝐷𝑣
Carga del vertedero (Cv) 3.75 m3/dm
SST en el efluente (SSTe) 135.60 mg/L
Tratamiento de lodos
La cantidad de sólidos suspendidos volátiles que ingresan al digestor (𝑆𝑆𝑉𝑜 ) fue determinada
aplicando un balance de masa de SSV de los lodos primarios y secundarios, como se indica a
continuación:
m3
Caudal que ingresa al digestor: Q o = 0,953538
d
Reemplazando los valores y despejando SSVo (Sólidos suspendidos volátiles que ingresan al
digestor):
𝑚𝑔
SSVo = 10703,775
L
En función del caudal y carga de sólidos volátiles, se realiza el dimensionamiento del digestor,
los cálculos se resumen en la Tabla 10. Adicionalmente, se implementará en el digestor un
sistema de medición de pH y los materiales de construcción permitirán el mantenimiento de la
temperatura necesaria para la digestión anaerobia.
Tabla 10: Parámetros de diseño del digestor anaerobio
Datos Unidad Fórmulas de diseño
El lecho típico de secado es de forma rectangular poco profundo con fondos porosos colocados
sobre un sistema de drenaje. El lodo se aplica sobre el lecho en forma de capas de 20 a 40 cm
de espesor que representa a la altura aplicada en este caso se ha escogido 20 cm y se deja
secar al ambiente. La altura total del lecho escogida es de 2 m (Villarroel, 2012).
El medio de drenaje va generalmente desde 0.30 m de espesor y deberá tener los siguientes
componentes: El medio de soporte recomendado está constituido por una capa de 0.15
m formada por ladrillos colocados sobre el medio filtrante, con una separación de 2 a 3 cm llena
de arena. La arena es el medio filtrante y deberá tener un tamaño efectivo de 0.3 a 1.3 mm y
el espesor de la capa escogido para el diseño es de 0.25 m. Debajo de la arena se deberá
colocar un estrato de grava graduada de 0.2 m de espesor (Maita, 2012).
Tabla 112: Valores de DQO, DBO5 y SST en la aguas residuales terminado el tratamiento de
lodos activados”
Parámetro (mg/L) Valor (mg/L)
DBO5 119,9
DQO 116,124
SST 135,60
tubo.
TRATAMIENTO PRELIMINAR
PRIMARIA
NOVAFORT de 2"
pérdida de carga y dificulta la
(Línea hacia el 0.8m (Plastigama , 2004)
adhesión de materiales a la pared
sedimentador
del tubo, lo que se traduce en
secundario)
menores costos de mantenimiento.
Se utilizó válvulas de paso integral
Válvula de esfera 2".
porque garantizan una sección
Paso integral. 1 (Giacomini, 2009)
libre de paso equivalente a la del
TRATAMIENTO SECUNDARIO
MODELO R910S.
tubo.
Tanque de Los tanques circulares son mucho
sedimentación más eficientes que los
1 (Lothar, 1998)
Acero inoxidable rectangulares evitando puntos
304 muertos de distribución.
Tubería
NOVAFORT de 2" Por ser liviana, resistente a ruptura
(Línea hacia el 1.5m y lisa, lo que implica una menor (Plastigama , 2004)
SEDIMENTACIÓN SECUNDARIA
DIGESTOR ANAEROBIO
atractiva y confiable.
Válvula de esfera
Válvula para la purga del lodo por
cromada, hembra,
el fondo del digestor, dos para la
palomilla roja y grifo (Giacomini,
4 entrada de los lodos (primario y
de descarga de 1/4”. 2009)
secundario), y otra para salida de
Paso estándar.
biol
MODELO: R251S
GESTIÓN DE LODOS
3.10. Presupuesto
El costo de los materiales y equipos necesarios para la construcción de una planta de tratamiento
de agua residual para la finca avícola Fincavic S.A. se detallan en la Tabla 144, alcanzando un
valor total de $11573.69
Tabla 144: Costos totales para la construcción de una planta de tratamiento de aguas
residuales para la finca avícola Fincavic S.A
PRECIO PRECIO
MATERIAL / DESCRIPCI
TRATAMIENTO UNITARIO CANTIDAD TOTAL
EQUIPO ÓN
($USD) ($USD)
Cemento
gris de gran
finura
TRATAMIENTO PRELIMINAR
7.95
Cemento 100 Kg 15.9
CANAL DE INGRESO
(50 Kg)
Enconfrado y
enlucido
Construcción del 50
2 m3 100.0
canal (m3)
Válvula con
esfera
DADO
Válvula de esfera 2". niquelada,
Paso integral. hembra, 52.39 1 52.39
MODELO R910S. palanca y
grifo de
descarga de
3/8”.
Tubo de
acero
Tubería NOVAFORT inoxidable,
de 2" (Línea hacia el redondeado, 54.016
medida de 0.8m 10.62
sedimentador (6.10 m)
secundario) 2”, largo de
6.10 m
Válvula con
esfera
DADO
Válvula de esfera 2". niquelada,
Paso integral. hembra, 52.39 1 52.39
MODELO R910S. palanca y
grifo de
REJILLAS
descarga de
3/8”.
Rejillas de
acero
Rejilla de limpieza inoxidable
350.16 1 350.16
manual
Tubo de
acero
Tubería NOVAFORT inoxidable,
54.016
de 2" (Línea hacia el redondeado, 0.8m 10.62
(6.10 m)
reactor) medida de
2”, largo de
SEDIMENTADOR PRIMARIO
TRATAMIENTO PRIMARIO
6.10 m
Válvula con
esfera
DADO
Válvula de esfera 2". niquelada,
Paso integral. hembra, 52.39 2 52.39
MODELO R910S. palanca y
grifo de
descarga de
3/8”.
Plancha de
acero
Planchas de acero inoxidable,
inoxidable (Tanque espesor 3 380.00 4 1552.00
circular) mm, tamaño
1200x2400m
m
Plancha de
acero
inoxidable,
Planchas de acero
espesor 3
inoxidable (Tanque 380.00 7 2660.00
mm, tamaño
rectangular - reactor)
1200x2400m
m
Potencia de
2.2 kW,
longitud total
de 1.520
Aireador OXYSTAR
mm, peso 37 649.83 1 649.83
OS 3.0
REACTOR AEROBIO
kg,
profundidad
de inmersión
500 mm.
Tubo de
acero
Tubería NOVAFORT inoxidable,
de 2" (Línea hacia el redondeado, 54.016
0.8m 7.08
sedimentador medida de (6.10 m)
secundario) 2”, largo de
TRATAMIENTO SECUNDARIO
6.10 m
Válvula con
esfera
DADO
Válvula de esfera 2". niquelada,
Paso integral. hembra, 52.39 1 52.39
MODELO R910S. palanca y
grifo de
descarga de
3/8”.
Plancha de
acero
inoxidable,
Planchas de acero
espesor 3
inoxidable (Tanque 380.00 4 1552.00
mm, tamaño
circular)
1200x2400m
SEDIMENTACIÓN SECUNDARIA
Tubo de
acero
Tubería NOVAFORT inoxidable,
de 2" (Línea hacia el redondeado,
1.5m 13.28
digestor anaerobio) medida de
2”, largo de
6.10 m
54.016
(6.10 m)
Tubería NOVAFORT
1.8m 15.94
de 2" (recirculación)
Tes iguales
de acero
inorxidable,
diámetro de
Unión T 15,89 1 15.89
2 ½”
Codo de
acero
inoxidable,
Codo de 90° con 3 diámetro 2
12.57 1 12.57
entradas ½”
Codo de
acero
galvanizado,
con diámetro
Codo de 90° 9.74 2 19.48
de 2 ½”
Válvula con
esfera
DADO
Válvula de esfera 2". niquelada,
Paso integral. hembra, 52.39 4 209.56
MODELO R910S. palanca y
grifo de
descarga de
3/8”.
Plancha de
acero
inoxidable,
Planchas de acero
espesor 3
inoxidable (Tanque 380.00 9 3420.00
mm, tamaño
DIGESTOR ANAEROBIO DE BAJA CARGA
rectangular - reactor)
1200x2400m
m
Válvula con
GESTIÓN DE LODOS
esfera
Válvula de esfera
DADO
cromada, hembra,
niquelada,
palomilla roja y grifo
hembra, 52.39 4 209.56
de descarga de 1/4”.
palanca y
Paso estándar.
grifo de
MODELO: R251S
descarga de
3/8”.
Válvula con
esfera
DADO
Válvula de esfera 2". niquelada,
Paso integral. hembra, 52.39 1 52.39
MODELO R910S. palanca y
grifo de
descarga de
3/8”.
Cemento
7.95
Cemento gris de gran 150 Kg 23.85
(50 Kg)
finura
30
Arena - 1.3 m3 39.0
(m3)
25
Grava - 1.4 m3 35.0
(m3)
6
Ladrillos - 10 m2 60.0
(m2)
Construcción del 50
LECHO DE SECADO
Enconfrado y 5 m3 250
lecho rectangular (m3)
enlucido
Tubo de
acero
inoxidable,
Tubería NOVAFORT 54.016
redondeado, 0.5m 27.01
de 4" (6.10 m)
medida de
4”, largo de
6.10 m
Válvula con
esfera
DADO
Válvula de esfera 2". niquelada,
Paso integral. hembra, 52.39 1 52.39
MODELO R910S. palanca y
grifo de
descarga de
3/8”.
TOTAL PRESUPUESTO ($) 11573.69
DISCUSIÓN
De acuerdo en la Tabla 2, donde se muestran las características de las aguas residuales de la
“Finca Avícola Fincavic S.A” , frente a las establecidas en el Texto Unificado de Legislación
Ambiental Secundaria del Ministerio de Ambiente (TULAS) para la descarga de efluentes al
sistema de alcantarillado público, podemos observar que los parámetros como demanda química
de oxígeno (DQO) , demanda bioquímica de oxígeno (DBO5) y solido suspendidos totales (SST)
no cumplen la normativa, se muestran valores para la Finca de DQO de 1136,465mg/L, DBO5
de 915mg/L y SST de 484,38 mg/L, motivo por el que se debe someter las aguas residuales a
un tratamiento antes de descargarlas para disminuir los valores de dichos parámetros y evitar
impactos ambientales .
La selección del tratamiento por lodos activados de las aguas residuales de la Finca Avícola
Fincavic S.A se dio debido a que el agua presenta una relación DQO/DBO 5 y DBO5/DQO de
1,242 y 0,80, respectivamente, indicando que las aguas residuales pueden ser tratadas con
sistemas biológicos ( Jiménez, 2000), además las aguas presentan valores de pH en el rango
adecuado (4 - 9) y nutrientes (N y P) para que los microorganismos cumplan su función de
descomponer la materia orgánica (Caldera et al, 2010).
Para poder reducir la concentración de la DBO 5, DQO y SST del agua residual de la finca se
empleó un sistema que constó de un tratamiento preliminar con rejillas, el cual tuvo una eficiencia
del 65% para remoción de SST, posteriormente se llevó a un sedimentador primario que presenta
una eficiencia de remoción de 34,48% para DBO 5, 56,34% para SST y 31,88% para DQO, se
pasó a un reactor aerobio removiendo el 85% de la DQO y 80% de DBO5 , finalmente se llevó a
un sedimentador secundario con una eficiencia del 30% para SST , dando como resultados una
disminución de DQO, DBO5 y SST en 116,124 mg/L, 119,9 mg/L y 135,60mg/L,
respectivamente, cumpliendo con los límites para descarga al sistema de alcantarillado público
especificado en el TULAS que son 500mg DQO/L, 250mg DBO5/L y 220 mg/L SST .
Como el sistema de lodos activados genera lodos no estabilizados (Limón, 2013), tanto el lodo
del sedimentado primario como el del sedimentador secundario se trataron con un digestor
anaerobio y un lecho desecado. El reactor anaerobio elegido fue de baja carga ya que los
compuestos volátiles fueron de 0,357 kg/d*m3, presentó un tiempo de retención de 30 días, con
una producción de sólidos aerobios de 1,748 Kg SSV/d y una producción de metano teórico de
2,63 Kg DQO/m3, el metano es recogido en un colector de gases, tanto el efluente y sólidos
provenientes del digestor y lecho de secado tienen usos futuros de biol y abono.
La selección de equipos y materiales se detalla en la Tabla 14, esta muestra que la planta tendrá
un costo alrededor de los $11573.69.
CONCLUSIONES Y RECOMENDACIONES
La planta de tratamiento fue eficiente para remover los parámetros DQO, DBO 5 y SST
en 116,124 mg/L, 915 mg/L y 135.60mg/L, respectivamente, cumpliendo con los límites
para descarga al sistema de alcantarillado público especificado en el TULAS .
La selección del tratamiento por lodos activados es un sistema eficiente para tratar las
aguas residuales de la Finca Avícola Fincavic S.A.
La planta tendrá un costo alrededor de los $11573.69.
Se recomienda monitorear las condiciones de pH y temperatura en el reactor anaerobio,
ya que la variación de estos podría ocasionar inconveniente en el proceso.
BIBLIOGRAFíA
Asetub. (2004). PVC y el agua Sistemas de tuberías de PVC. Recuperado el 17 de Enero
de 2017, de www.asetub.es/component/docman/doc_download/34-pvc-y-el-
agua?Itemid=628
Anhalzer, P. (2016). La industria avícola ecuatoriana registra un crecimiento sostenido.
Recuperado el 20 de enero del 2017, de:
http://edicionimpresa.elcomercio.com/es/082300000aedd091-6159-44a6-b4a5-
bceb00c33b7f
Bustos, I. (2012). Diseño del sistema de tratamiento de aguas residuales de las etapas
rivera y curtido para la tintorería San José. Obtenido de Tesis de Pregragrado- Escuela
Superior Politécnica de Chimborazo:
http://dspace.espoch.edu.ec/bitstream/123456789/2025/1/96T00167.pdf
Cajas, A. (2014). Diseño Del Sistema De Tratamiento De Aguas Residuales En El Centro
De Salud N°2 En La Ciudad De Ambato Provincia De Tungurahua. Recuperado el 30 de
Diciembre de 2016, de Escuela Superior Politécnica De Chimborazo :
http://dspace.espoch.edu.ec/bitstream/123456789/3205/1/96T00239.pdf
Caldera, Y., Gutiérrez, E., Luengo, M., Chávez, J., Y Ruesga, L. (2010). Evaluación del
sistema de tratamiento de aguas residuales de industria avícola. Revista Científica, vol.
XX (4), pp. 409-416.
Calvache, W., Chaves, M., Durán, C., Guaña, E., Imba, A., & Nasate, W. (2002).
Recuperado el Diciembre de 2014, de
https://books.google.com.ec/books?id=Y44LHaIpkqwC&printsec=frontcover&hl=es&sou
rce=gbs_ge_summary_r&cad=0#v=onepage&q&f=false
Cevallos, M., Ramos, A. (2009). Diseño de un biodigestor anaerobio. Recuperado del 23
de enero de 2017, de http://repositorio.espe.edu.ec/bitstream/21000/308/9/T-ESPE-
026444-5.pdf, pp. 132.
Crites, R., & Tchobanoglous, G. (2000). Tratamiento de aguas residuales en pequeñas
poblaciones (Vol. 1). Santa Fé, Colombia: Mc Grawhill.
DISEPROSA. (s.f.). Plantas de tratamiento de aguas. Recuperado el 28 de diciembre de
2014, de
http://www.interempresas.net/FeriaVirtual/Catalogos_y_documentos/87264/Plantas_de
_Tratamiento_de_Aguas.pd
FAO. (1992). Wastewater treatment and use in agriculture. Corporate Document
Repository.
FAO (2011). Manual de biogas, Recuperado del 23 de enero de 2017, de:
http://www.fao.org/docrep/019/as400s/as400s.pdf
FUCHS. (2014). Aireador OXYSTAR. Recuperado el 19 de Enero de 2017, de
http://www.fuchsgermany.com/fileadmin/download_pdf/downloadcenter_es/Aireador_F
UCHS_OXYSTAR_Foletto_espanol_2014-01.pdf
García, P. (2010). Calidad de Agua - Lodos Activados - Guia Ambiental. Recuperado el
20 de enero del 2017, de : http://www.guiaambiental.com.ar/conocimiento-calidad-de-
agua-lodos-activados.html
Giacomini. (2009). Válvulas de esfera. Recuperado el 17 de Enero de 2017, de
http://old.giacomini.com/export/sites/default/es/download_gallery/pdf_catalogo_doc_tec
_spagna/familia_6/1264665823116_Valvulas_de_esfera.pdf
Hammeken, A., & Romero, E. (2005). Análisis y diseño de una planta de tratamiento de
agua residual para el municipio de San Andrés Cholula. Recuperado el 29 de Diciembre
de 2016, de Universidad de las Américas Puebla. :
http://catarina.udlap.mx/u_dl_a/tales/documentos/lic/hammeken_a_am/capitulo5.pdf
Hess, M. (2000). Pequeños sistemas de tratamiento de aguas residuales. Obtenido de
Centro Interamericano de Desarrol lo Integral de Aguas y Tierras.
Jiménez, A. (2000). Determinación de los parámetros fisicoquímicos de calidad de las
aguas. Universidad Carlos III. España. Obtenido de < http://ocw.uc3m.es/ingenieria-
quimica/ingenieria-ambiental/otros-recursos-1/OR-F-001.pdf> Extraído [29/11/2016].
Limón, J. (2013).LOS LODOS DE LAS PLANTAS DE TRATAMIENTO DE AGUAS
RESIDUALES, ¿PROBLEMA O RECURSO?. Recuperado el 20 de enero del 2017, de
:
http://www.ai.org.mx/ai/images/sitio/201309/ingresos/jglm/doc_ingreso_gualberto_limon
_trabajo_de_ingreso.pdf
Lozano-Rivas, W. (2013). Diseño de Plantas de Tratamiento de Aguas Residuales.
Módulo didáctico. Recuperado el 30 de Diciembre de 2016, de Universidad Nacional
Abierta Y A Distancia - UNAD:
datateca.unad.edu.co/contenidos/358039/Modulo_verson_julio_2013.pdf
Lorenzo,Y & Obaya, M. (2005). La digestión anaerobia: Aspectos teóricos. Recuperado
el 19 de enero del 2017 de http://www.redalyc.org/pdf/2231/223120659006.pdf
Maita, J. (2012). IMENSIONAMIENTO DE UNA PLANTA DE TRATAMIENTO DE
AGUAS RESIDUALES PARA LA CABECERA PARROQUIAL DE LICÁN. Recuperado el
13 de Enero de 2017, de i ESCUELA SUPERIOR POLITÉCNICA DE CHIMBORAZO:
http://dspace.espoch.edu.ec/bitstream/123456789/2010/1/236T0062.pdf
Maldonado, M. (2010). Proceso de secado de lodo . Recuperado el 17 de Enero de 2017,
de http://catarina.udlap.mx/u_dl_a/tales/documentos/lpro/maldonado_g_ma/
MARN. (10 de Abril de 2015). Aireación prolongada. Recuperado el 2017, de Ministerio
de Medio Ambiente y Recursos Naturales, Observatorio del Agua, Gobierno de El
Salvador:http://agua.marn.gob.sv/Documentos/TallerAguas2015/AIREACION_PROLO
NGADA_V3.pdf
Metcalf, R., & Eddy, P. (1995). Ingeniería de aguas residuales. Tratamiento, vertido y
reutilización. Madrid: Mc Graw - Hill Interamericana.
Ortiz, Y., y Lon Wo, E., (2016). Efecto de los residuales avícolas en el ambiente.
Recuperado el 20 de enero del 2017, de Instituto de Ciencia Animal de Cuba
:http://www.fertilizando.com/articulos/efecto%20residuales%20avicolas%20ambiente.as
p
Organización Panamericana dela Salud PAO (2005). Guía para el diseño de
desarenadores y sedimentadores. Desarrollo sostenible. Recuperado de:
http://www.bvsde.paho.org/bvsatp/e/tecnoapro/documentos/agua/158esp-diseno-
desare.pdf
Ramalho, R. (1996). Tratamiento de aguas residuales (Revisada ed.). Barcelona,
España: Reverté.
Saldes, L. G., & Alkalay Lowitt, D. (2004). TRATAMIENTO DE RESIDUOS LÍQUIDOS
DE UNA FÁBRICA DE GALLETAS. Universidad Técnica Federico Santa María, Casilla
110 - V, Valparaíso, Chile.
Sánchez, J. (2010). Modelamiento de las condiciones hidráulicas de una planta
compacta para el tratamiento de aguas residuales domésticas. Obtenido de Tesis
Magistral - Universidad Nacional de Colombia:
http://www.bdigital.unal.edu.co/2006/1/8646493.2010.pdf
Suárez, A., Jácome, P: Ures, M. (2015). Equalization tank / Homogenization tank. FS-
PRET-002. Technology fact sheets for effluent treatment plants on textile industry. pp. 7.
Recuperado de: https://www.wateractionplan.com/documents/186210/186352/INDITEX-
FS-PRET-002-Ecualization+homogenization.pdf/6dfa6898-93d5-4329-9b51-
6c9ee6ead7d8
TULAS. (2003). Norma de Calidad Ambiental y de Descarga de Efluentes: Recurso Agua.
Libro VI. Anexo I. Ecuador.
Uralita. (2014). Sistemas de Tuberías. Recuperado el 17 de Enero de 2017, de
https://www.interempresas.net/Construccion/FeriaVirtual/Escaparate-Adequa-Uralita-
198125.html
Valencia, A. (2013). DISEÑO DE UN SISTEMA DE TRATAMIENTO PARA LAS AGUAS
RESIDUALES DE LA CABECERA PARROQUIAL DE SAN LUIS – PROVINCIA DE
CHIMBORAZO. Recuperado el 12 de Enero de 2017, de
http://dspace.espoch.edu.ec/bitstream/123456789/3118/1/236T0084.pdf
Villarroel, J. (2012). RATAMIENTO DE AGUAS RESIDUALES DOMESTICAS
MEDIANTE HUMEDALES ARTIFICIALES EN LA COMUNIDAD DE RUMICHACA.
Recuperado el 13 de Enero de 2017, de UNIVERSIDAD NACIONAL AGRARIA LA
MOLINA:
www.lamolina.edu.pe/proyectos/proyecto_AQUAtech/Diplomado_III/monografias/pdf_d
oc/VILLARROEL.pdf
Zambrano, A. (2017). Guayaquil sede del XXIV Congreso de avicultura.
Recuperado el 20 de enero del 2016, de Revista Agro:
http://www.revistaelagro.com/wp-content/uploads/2012/08/septiembre.pdf
PLANOS PROPUESTOS PARA EL
DISEÑO DE LA PLANATA DE
TRATAMIENTO DE LA FINCA
AVÍCOLA FINCAVIC S.A