Sustainable cooling solution

Benefits
• Cleaning of process water
(control and prevention of the
risk of legionella)
• The closed loop system redu-
ces maintenance costs, preven-
ting the formation of scale on
pipes and molds
• Increased water saving: the
adiabatic phase only starts
operating at certain times of
the year
• Water treatment is limited to
the adiabatic phase only
• Reduction in power consump-
tion: thanks to electronic fans
(EC) and rotation speed modu-
lation during partial loads
• Automatic anti-pollen cycle.
In the case of the presence of The Aquatech Dry Cooler offers many Aryacool is available in two versions:
pollen or foliage, it is possible advantages for process water cooling in
•Dry System: Used when the process
to set automatic cycles that re- industrial plants.
water temperature is 5°C above the
verse the fan rotation direction ambient air temperature.
and push all superfluous mate- By the use of a pressurized circuit, it
is possible to keep the process water •Adiabatic system: used in periods of
rials outwards clean, thereby avoiding the risk of the high ambient temperature; sprayers
growth and spread of legionella. In the nebulize water directly on the heat
adiabatic version, Aryacool uses only the exchanger, promoting the cooling of
quantity of water that is strictly needed, both incoming air and the battery in
reducing waste and operating costs. contact with the water.

In both configurations, finned batteries can be specially treated to withstand hi-


ghly corrosive environments, such as those in chemical industries or plants loca-
ted near marine areas.
On request, a self-draining version or a version with PADS is available
Main features:
- Application flexibility: various sizes and thermal capacities,
suitable for Free-Cooling or for condensation (water cooled
chillers).
- Increased energy savings, thanks to EC fans.

LF_ARC_01_2018_REV.00 - Disclaimer: data in this document may be out of date. Please consult technical data sheet
- Water consumption reduced to a minimum, thanks to a system
that uses water evaporation only during periods of high outdoor
air temperature.

Model L
FCW450-550-650 Max. 4135 mm
FCW750-850 Max. 5335 mm
FCW950 Max. 6135 mm
FCW1050 Max. 6535 mm

Model L W
FC200 4730 mm 1390 mm
FC250 6730 mm 1390 mm
FC300-350 3930 mm 2380 mm
FC400 4730 mm 2380 mm

TECHNICAL DATA DRY Mode (1) ADIABATIC Mode (2)


Nominal Water flow Water presure Nominal Water Water presure Input Water
Fans Weight(3)
capaciy rate drop capaciy flow rate drop power connetions
Model [kW] [m3/h] [kPa] [kW] [m3/h] [kPa] n. [kW] DN [kg]
FC200 213,7 39,9 54,8 276,7 51,7 86 2 4,84 80 688
FC250 244,5 45,7 36,7 319,7 59,8 58,6 3 7,47 100 839
FC300 303,9 56,8 56,4 398,1 74,4 90,5 4 9,76 80 909
FC350 346,3 64,7 48,2 452,6 84,6 76,9 4 10,2 80 940
FC400 414,4 77,5 59,5 535,6 100,1 93,3 4 9,92 100 1140
FCW450 451,8 84,4 30 607,7 113,6 50,3 6 13,44 80 1383
FCW550 566,6 105,9 18,3 755 141,1 30 6 14,46 80 1543
FCW650 621 116 15,8 821,3 153,5 25,5 6 15 80 1627
FCW750 730,6 136,5 55,8 959,3 179,3 89,9 8 18,56 100 1915
FCW850 831,1 155,3 34,4 1085 202,8 54,7 8 20 100 2132
FCW950 922 172,3 48,2 1195,1 223,3 75,9 8 19,12 100 2450
FCW1050 1067,2 199,4 66,4 1379,5 257,8 104,1 10 25 100 2638

(1) Air temperature 25°C, water inlet temperature 40°C, water outlet temperature 35°C (ethylene glycol 30%)
(2) Air temperature 35°C (relative humidity 30%), water inlet temperature 40°C, water outlet temperature 35°C (ethylene glycol 30%)
(3) Empty value