You are on page 1of 3

INCOME TAX RETURN

MEDICAL FILE (PRESCRIPTION AND MEDICINE)


AFX 241
OIL CHANGING OF AFX 241----
INSPECTION OF WIRING TEST REPORT
MAINTENANCE BILL OF AFX 241
ISSUED MATERIAL TO PROJECT (APRIL 2017 TO JUNE 2018)
PARAMETER OF VFD --- PROTECTION SETTING
PASS WORD AND SOFTWARE AND PROGRAM --- PARTS LIST -
MOTOR BEARING LIST
VARIATION LIST--COPY OF CONTRACT---PENDING ISSUES
CASH CLOSING
BANK STAEMENTS + TEX STATEMENT
EOCR on fan and 37kw and above
Cooling types of large motors

Drawout Modules are with-drawable with 3


distinct position viz Test, Service 8 Isolation

SAMCON FEATURES ADVANTAGES

Fully compartmentalized Ensures operator safety.


Drawout Modules are with-drawable with 3
Low Down Time
distinct position viz Test, Service 8 Isolation.
Drawout Modules of same size are fully
Easy Replacement
interchangeable.
Totally enclosed, vermin-proof & dust proof Prevents Accidental Contacts & Short
Vertical Busbar system Circuit
Prevents Accidental Contacts & Short
Automatic safety shutter for the vertical bus-bar.
Circuit
Main bus-bars are easily approachable from the
Easy Supervision & Maintenance
top.
Self-aligning & self-disconnecting power &
No Mismatch of Contacts
auxiliary Control contacts.
Prevents Damage to Main V BUS even
Vertical bus-bars are provided with contact
after
Element for Drawout contacts
number of insertions.
Spring Loaded Earth Contacts Ensures Safely
Swivelling lever- guide for easy withdrawal
Easy Supervision & Maintenance
of the modules without any additional tools.
Feeder & cable alley doors open in opposite Ease For Maintenance &
directions providing ample working space. Commissioning person

Salient features of MCC / PCC enclosure :


• Fully compartmentalized design.
• Draw out trolleys/module incoming and outgoing power and control contacts automatically also late without manual
disengagement in three distinct • position i.e. service, test isolate.
• All Draw out units are fully interchangeable.
• Totally enclosed vermin and dustproof.
• Safety shouters provided accidental contact from vertical bus bars.
• Latest design of our draw out enclosure provide maintenance free vertical bus bars with our joint.
• Main bus bar HBB are approachable from the top.
• Self aligning and disconnecting power and control contact.
• Racking Screw arrangement with telescopic rails system provide safe and sure. Smooth movement like Draw out and
insertion if module.
• New design provide top and bottom guide along with swiveling lever for easy module withdrawal without tools.
• Modular construction with wide choice of compartment size.
• Standard module size minimum 225mm and up to 1500mm height in step of 75rnm.
• Bolted design and assembly allow ease of alteration of extension at site.
• Hinged auxiliary door inside main compartment door permit mounting of control accessories, such as meters, selector
switch, indicating lamps, push buttons and reset actuator.
• Further this system improve better utilization of equipment plate and total interchangeability of trolleys.
• Spring loaded scraping earthling provided with first make and last brake arrangement.
• Maximum eight numbers auxiliary bus bar center provide in top chamber and segregation from HBB zone.
• Large cabling space with adequate cable supports, are provided in CBC.
• Incoming and outgoing stab in type power contacts up to 800Amps. Provide very large range of feeders of different types.

Technical Data :

Rated voltage 600volts, 50HZ.


Phase 3 phase and neutral of 4 poles.
Rated current Main Bus bar -3200Amp Vertical bus bar-800Amp
Short circuit
Standard 50ka 1 second Optional 65ka 1 second
strength
Enclosure type IP-52
Horizontal Aluminum 3200A max Vertical Aluminums 800Amp
Bus bar material max
and Cooper 1000Amp max
Bus bar support SMC (FRP)
Single front 800/850 W x 600D x 2400H. Max
Dimension
Double front 800/850W x 800D x 2400H. Max.
Standard IS 8623.1993 and IEC 61439/60439

SHORT CIRCUIT KA RATING OF MCC COMPONENTS

INSULATION OF BUSBARS

(MAKE / MODELS)

AIR CONDITIONING LIGHTING FIXTURES

VFD VCB ACB MCC

MAGNATIC CONTACTOR AUX RELAYS

SSC SSR THERMAL OVERLOAD

EOCR PROTECTION RELAY SOFT STARTER

LOW VOLTAGE MOTORS REHOSTAT

UPS BATRY CHARGER MV CABLES MV MOTORS

POWER TRANSFORMERS