You are on page 1of 1

DR.

FIXIT PIDICRETE CF 310


High Range Water Reducing cum Retarding Admixture
for Concrete

Dr. Fixit Pidicrete CF 310 is a Plasticizing admixture COMPATIBILITY:

CONCRETE ADMIXTURES
to produce pumpable or flow able concrete, free from Dr. Fixit Pidicrete CF 310 is compatible with all types
bleeding and segregation. of cement e.g. OPC, PPC, PSC etc.
It also imparts the cohesiveness to concrete mix for easy Dr. Fixit Pidicrete CF 310 is compatible with all air
placing and pumping. entraining agent which complies wiith IS 9103-2003
and Integral water proofing compound which complies
SPECIFICATION AND STANDARD with IS 2645- 1978. If other admixtures are to be used
IS: 9103-1999 and ASTM-C-494-86, Type G in concrete containing Dr. Fixit Pidicrete CF 310 they
must be dispensed separately.
AREAS OF APPLICATION
Precast Concrete STORAGE :
High Performance Concrete • Keep the liquid above freezing temperature.
• If the product has frozen, thaw it at room
FEATURES & BENEFITS temperature(25°C) and agitate until complete
Water reduction upto 25-28% without effecting the reconstitute in the original form.
workability • Store under cover, protect from direct sunlight.
Helps in reducing cement content for a required strength • Failure to comply with recommended storage condition
by reducing w/c ratio. may result in premature deterioration of the product
Achieve high early strength. and packaging.
Increases workability at a given w/c ratio, resulting easy
placing, and eliminates honeycombing. SAFETY PRECAUTIONS :
Reduction in shrinkage cracks •Dr. Fixit Pidicrete CF 310 is a non-toxic and
Less permeable and hence more durable concrete. inflammable. When in contact with the skin, it should
be washed with cold water.
METHOD OF APPLICATION :
Concrete shall be mixed with 50-70% of the mixing TECHNICAL INFORMATION :
water(based on mix design by weight). Appearance - Dark Brown Liquid
The correct quantity of Dr. Fixit Pidicrete CF 310 should Sp.Gravity - 1.20 +/- 0.02
be measured with recommended dispenser and should be Chloride content - Nil
added to the concrete with remaining 30% mixing water pH Value - 7±1

DR . FIXIT Pidicrete CF 160


and allow to mix it for recommended mixing time.
Dr. Fixit Pidicrete CF 310 should not be added in dry
mixes under any circumstances PACKING :
265 Kgs, 250 Kgs, Tanker Supply
DOSAGE:
Dosage range of Dr. Fixit Pidicrete CF 310 will be 400 ml
to 1200 ml per bag of cement.
CC-DF-PIDI-CF-160-FLR-ENG-06/08

Optimum dosage should be determined by doing site trial


mixes. Dosage may go above maximum limit for High
Performance Concrete and shall be determined by site
trial mix.

Disclaimer: The product information & application details given by the company
Pidilite Industries Limited & its agents has been provided in good faith & meant to serve only as a general
Construction Chemicals Division guideline during usage. Users are advised to carry out tests & take trials to ensure
on the suitability of products meeting their requirement prior to full scale usage
Ramkrishna Mandir Road Post Box No. 17411 of our products. Since the correct identification of the problems, quality of other
Andheri (E) Mumbai 400059 INDIA materials used and on-site workmanship are factors beyond our control, there
are no expressed or implied guarantee / warranty as to the results obtained.
Tel +91-22-2835 7000 Fax +91-22-2835 7008 The Company does not assume any liability or any consequential damage for
website www.doctor-fixit.com E-mail drfixit@pidilite.com unsatisfactory results, arising from the use of our products.