To measure the power in 3 -phase balanced star and delta connected load and to determine the
power factor.
This experiment helps students to understand power measurement in 3-phase circuits and to
determine the power factor of the given load.
Two wattmeter method is the most suitable method for the power measurement in 3Φ circuits. It is
applicable for balanced as well as unbalanced 3Φ load . Power factor can also be determined by this
method.
IN STAR CONNECTION
iB = -(iR + iY).
Instantaneous power
= iRvRB + iYvYB.
= W1 + W2.
vRY + vYB + vBR = 0 Where vRY, vYB, vBR are instantaneous voltages.
= W1 + W2.
Thus in both star and delta circuits, the sum of the two wattmeter readings w1 and w2 is equal to
the total power consumed in the circuit.
FORMULA: P = √3VLILcos Φ
Φ=tan-1[√3(w2 – w1)]
(w2 + w1)
Figure No.1
Figure No.2
6. Apparatus Required
1.Wattmeter 250 V, 5A
7. Experimental Procedure
1. Connect the circuit as shown in the Figure No1 to measure the power in star
connected load.
8 Observation Table
OBSERVATION TABLE:
STAR
CKT
DELTA
CKT
2.Draw the phasor diagram and prove that sum of two wattmeter reading is equal to 3-
phase power