You are on page 1of 24

Inverter Air Conditioning

for Light Commercial Use


2

DI Digital Inverter
Toshiba continues to improve its range of split systems dedicated to commercial applications. Digital Inverter (DI),
compact and last effective. This has been totally redesigned to 4&5 HP model. The performance of these systems
provide significant energy savings for a rapid return on investment. Energy savings, comfort, ease of installation
and simplicity are the strengths Toshiba systems.

Remarkable energy efficiency Wide-Utility function


Industry's top-class energy-saving (Max. 10% up) Heater operation is possible starting from an outdoor
temperature of -15°C, while cooling operation is possible
at -15°C and up to 46 outdoor temperature. This enables
wider applications and use of the system in colder regions.

Extremely lightweight and Small compact size chassis


compact outdoor unit Reduces installation spaces and enables a more efficient
use of the site. Easy to install the outdoor units on a
Lighter than the current model by 8 kg. (11%)
double-decked and easy to install on a wall.

4 HP RAV-SM1104AT(J)P-E
68kg. -8kg.
5 HP RAV-SM1104AT(J)P-E (previous model: 76kg.) Current model
New model

Easy and safety operation for maintenance of the outdoor unit


Inspection window makes it easy to find switch that requires operation and reduces the risk of electrical shock.
1 ~ 3HP 4 ~ 5HP

Inspection window
Cover

Maintenance Switch (2 tact switches)

Maintenance light (6LED)

Outstandingly quiet operation & save operation setting


Night operation make it possible to suppress the operation sound of the outdoor unit
within the time which you desire. [12dB(A) reduction]*

Save operation setting is available from 50% to 100% by 1%


Quiet operation & save operation setting available for 1HP to 5HP
*5HP Outdoor unit, Heating.
Note: Night operation - Necessity to set the Lite-vision plus remote controller (RBC-AMS51E)
Save operation - Necessity to set the Lite-vision plus remote controller (RBC-AMS51E), (RBC-AMT32E)
3

DI BIG
Digital Inverter BIG proposes competitive cost systems solution for medium size applications like Shops and Small
Office buildings. Simultaneous operation of 2, 3 or up to 4 indoor unit can be installed as twin, triple and double
twin systems with single outdoor unit.

Expanded operating temperature range


Air conditioning system designing is easy with BIG Digital BIG Digital Inverter
Inverter because of its expanded operation range. Heater
operation is possible starting from an outdoor temperature Outdoor temp. range when heating*
of -20°C, while cooling operation is possible at -15°C
and up to 46 outdoor temperature. This enables wider Outdoor temp. range when cooling*

applications and use of the system in colder regions.


-20°C-15°C 0°C 15°C 46°C
*Cooling: °C DB, Heating: °C WB

High efficiency EER/COP* performance


BIG Digital Inverter is equipped with a new twin-rotary DC inverter compressor with high efficiency R410a refrigerant.

A new technology twin-rotary DC compressor, 100W +100W output Highly-efficient DC fan motor, propeller fan for
newly developed 3-row heat exchanger.

Wider discharge port for less pressure loss


Screw connection for larger current

Decreasing oil discharge for reliability


Compact & higher efficiency motor
1. Rare metal magnet
2. Highly concentrated & optimized winding
*EER / COP = 3.21 / 3.85
(With 4-way cassette twin system of 8HP),
Larger displacement cylinder (55 cm3/rev)
EER / COP = 2.81 / 3.61
(With 4-way cassette twin system of 10HP),

Small footprint and suilable for Compatible with pipes up to 70 meters


balconies long with a maximum height difference
The outdoor unit has a small physical footprint of only
of 30 meters height
0.29m2, taking up as little space outside as possible.
Installations can reach up to 70 m in total length and 30 m
in elevation.
The outdoor unit is compact and expels exhaust air to the
side, so it can be installed even in limited spaces as shown.

0.29m2

0.90m 0.32m
4

Indoor units
1:1 by combination

HP equivalent Compact 4-way cassette 4-way cassette Slim duct Standard duct
1.0 HP RAV-SM304MUT-E RAV-SM304SDT-E
1.5 HP RAV-SM404MUT-E RAV-SM404SDT-E
2.0 HP RAV-SM564MUT-E RAV-SM564UTP-E RAV-SM564SDT-E RAV-SM566BTP-E
3.0 HP RAV-SM804UTP-E RAV-SM806BTP-E
4.0 HP RAV-SM1104UTP-E RAV-SM1106BTP-E
5.0 HP RAV-SM1404UTP-E RAV-SM1406BTP-E
6.0 HP RAV-SM1604UTP-E RAV-SM1606BTP-E

HP equivalent Ceiling High wall High wall Concealed duct high static pressure

1.0 HP RAV-SM307KRTP-E
1.5 HP RAV-SM407CTP-E RAV-SM407KRTP-E
2.0 HP RAV-SM567CTP-E RAV-SM566KRT-E
3.0 HP RAV-SM807CTP-E RAV-SM806KRT-E
4.0 HP RAV-SM1107CTP-E
5.0 HP RAV-SM1407CTP-E
6.0 HP RAV-SM1607CTP-E
8.0 HP RAV-SM2242DT-E*
10.0 HP RAV-SM2802DT-E*
* RAV-SM***2DT-E can be connected to RAV-SM***4AT8-E only.

DI BIG: 8.0, 10.0 HP

DI: 6.0 HP

DI: 4.0, 5.0 HP


DI: 1.0, 1.5, 2.0, 3.0 HP
5

Outdoor units

Digtal Inverter1-phase model

HP equivalent 1.0 HP 1.5 HP 2.0 HP 3.0 HP


Standard RAV-SM304ATP-E RAV-SM404ATP-E RAV-SM564ATP-E RAV-SM804ATP-E
Model name 50Hz Light Anti-Corrosion protection - - -
Heavy Anti-Corrosion protection RAV-SM304ATJP-E RAV-SM404ATJP-E RAV-SM564ATJP-E RAV-SM804ATJP-E
Cooling capacity (kW) 2.5 3.6 5.0 6.7
Heating capacity (kW) 3.4 4.0 5.3 7.7

Digtal Inverter1-phase model

HP equivalent 4.0 HP 5.0 HP 6.0 HP


Standard RAV-SM1104ATP-E RAV-SM1404ATP-E RAV-SM1603AT-E
Model name 50Hz Light Anti-Corrosion protection - - RAV-SM1603ATZ-E
Heavy Anti-Corrosion protection RAV-SM1104ATJP-E RAV-SM1404ATJP-E RAV-SM1603ATZG-E
Cooling capacity (kW) 10.0 12.0 14.0
Heating capacity (kW) 11.2 12.8 16.0

Digtal Inverter BIG


3-phase model

HP equivalent 8.0 HP 10.0 HP


Standard RAV-SM2244AT8-E RAV-SM2804AT8-E
50Hz Light Anti-Corrosion protection RAV-SM2244AT8Z-E RAV-SM2804AT8Z-E
Heavy Anti-Corrosion protection RAV-SM2244AT8ZG-E RAV-SM2804AT8ZG-E
Model name
Standard RAV-SM2244AT7 RAV-SM2804AT7
60Hz Light Anti-Corrosion protection RAV-SM2244AT7Z RAV-SM2804AT7Z
Heavy Anti-Corrosion protection RAV-SM2244AT7ZG RAV-SM2804AT7ZG
Cooling capacity (kW) 20.0 23.0
Heating capacity (kW) 22.4 27.0
6

Compact 4-way cassette type


Perfectly fit for 600 x 600 grid system ceiling

Perfect for grid system ceiling

This compact unit (575 x 575 mm) fits perfectly into ceilings and matches
RAV-SMxx4MUT-E standard architectural modules, without the need to cut ceiling tiles.

Designed for simple & easy installation and maintenance

Panel The slim flat stylish panel design is only 268 mm in height even when an
electrical box is located inside the unit. Easy access to electrical box is achieved
by simply removing the suction grill. Easy installation is also possible using the
panel adjust pocket. Use the “adjust pocket” function for fine adjustments after
installation.

The drain up height is 850 mm. Available for ceilings up to 3.5 m in height.

RBC-UM11PG(W)-E

3.5m

Maximum height

Options

Auxiliary fresh air flange


TCB-FF101URE2

Ceiling panel
RBC-UM11PG(W)-E
7

Technical specifications
Indoor unit (RAV-) SM304MUT-E SM404MUT-E SM564MUT-E
Standard (RAV-) SM304ATP-E SM404ATP-E SM564ATP-E
Outdoor Light Anti-Corrosion protection (RAV-) - - -
unit
Heavy Anti-Corrosion protection (RAV-) SM304ATJP-E SM404ATJP-E SM564ATJP-E
Power supply 1-phase 50Hz 220–240V / 1-phase 60Hz 220V
Capacity kW 2.5 3.6 5.0
Range, min-max kW 0.9-3.0 0.9-4.0 1.5-5.6
Power consumption kW 0.59 0.90 1.65
Cooling*1
Capacity 100% 4.24 4.00 3.03
EER
(Energy Capacity 80% 4.26 4.30 3.81
Efficiency Ratio)
Capacity 50% 4.03 4.86 4.90
Capacity kW 3.4 4.0 5.3
Range, min-max kW 0.8-4.5 0.8-5.0 1.5-6.3
Power consumption kW 0.76 0.95 1.52
Heating*1
Capacity 100% 4.47 4.21 3.49
COP
(Coefficient of Capacity 80% 4.69 4.85 3.93
Performance)
Capacity 50% 5.31 5.88 4.91
Indoor unit
Standard air flow (H/M/L) m3/h 640/520/440 660/552/468 798/672/546
Sound pressure level (H/M/L) dB(A) 40/36/31 40/36/31 43/39/34
Sound power level (H/M/L) dB(A) 55/51/46 55/51/46 58/54/49
Main unit dimensions (H/W/D) mm 268/575/575 268/575/575 268/575/575
Weight kg 16 16 16
Panel dimensions (H/W/D) mm 27/700/700 27/700/700 27/700/700
Panel weight kg 3 3 3
Outdoor unit
Compressor type DC rotary DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø9.5 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4
Standard / Min. pipe length m 7.5 / 2 7.5 / 2 7.5 / 5
Max. pipe total length m 20 20 30
Maximum height difference m 10 10 30
Outer dimensions (H/W/D) mm 550/780/290 550/780/290 550/780/290
Weight kg 33 39 40
Standard air flow (Fan unit) m3/h 1800 2200 2400
Sound pressure level, Cooling/Heating*2 dB(A) 46/47 49/50 46/48
Sound power level, Cooling/Heating dB(A) 61/62 64/65 63/65
Operating range, Cooling/Heating °C -15~46 / -15~24 -15~46 / -15~15
*1 Rated conditions Cooling : Indoor air temperature 27oC DB / 19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB / 6oC WB
*2 Sound pressure levels measured in an anechoic chamber
8

4-way cassette type


The wide air flow in all direction

Multi-louver individual control

Individual louver control enables airflow to be chosen according to user


RAV-SMxxx4UTP-E preferences. The angles of each louver can be set individually in 3 different
choices of swing patterns; Standard swing, Diagonally opposite swing and
Easy installation Turn-around swing.

Light weight unit (24kg at 5HP) Easy panel (1) Standard swing (2) Diagonally opposite swing
installation, The panel is attached using the bolt
that is already installed on the indoor unit.

(3) Turn-around swing

Built-in condensate drain pump

300mm or less

New long-life pre-filter


850mm or less

A new long-life pre-filter has a surface 1.5 times


210mm
of current filters to improve Dust-collection
performace.

Options

TCB-GFC1602UE
TCB-FF101URE2

Spacer for height adjustment

Air discharge direction kit


Fresh air inlet box
TCB-BC1602UE
TCB-GB1602UE

RBC-U31PGP(W)-E
Air discharge
parts A
Drain piping
side
Packing A
Spacer for height adjustment Refrigerant Air discharge
TCB-SP1602UE
Air discharge
piping parts C
side
parts B Packing B
Panel
Packing B
RBC-U31PGP(W)-E
RBC-U31PGP(WS)-E
RBC-U31PGP(WS)-E Air inlet grille
9

Technical specifications
Indoor unit (RAV-) SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E SM1604UTP-E
Standard (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E
Outdoor Light Anti-Corrosion protection (RAV-) - - - - SM1603ATZ-E
unit
Heavy Anti-Corrosion protection (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E
Power supply 1-phase 50Hz 220–240V / 1-phase 60Hz 220V 1-phase 50Hz 230V (220-240V)

Capacity kW 5.0 6.7 10.0 12.0 14.0


Range, min-max kW 1.5-5.6 1.5-8.0 3.0-11.2 3.0-13.2 3.0-16.0
Power consumption kW 1.56 2.22 3.02 4.29 4.49
Cooling*1
Capacity 100% 3.21 3.02 3.31 2.80 3.12
EER
(Energy Capacity 80% 4.00 3.77 4.08 3.53 3.98
Efficiency Ratio)
Capacity 50% 5.21 5.49 5.10 5.00 4.86
Capacity kW 5.3 7.7 11.2 12.8 16.0
Range, min-max kW 1.5-6.3 1.5-9.0 3.0-13.0 3.0-16.0 3.0-18.0
Power consumption kW 1.36 2.13 2.93 3.40 4.43
Heating*1
Capacity 100% 3.90 3.62 3.82 3.76 3.61
COP
(Coefficient of Capacity 80% 4.37 4.22 4.23 4.30 4.59
Performance)
Capacity 50% 5.41 5.50 5.19 5.12 4.91
Indoor unit
Standard air flow (H/M/L) m3/h 1050/870/780 1230/960/810 2010/1440/1170 2100/1440/1230 2130/1500/1260
Sound pressure level (H/M/L) dB(A) 32/29/28 35/31/28 43/38/33 44/38/34 45/40/36
Sound power level (H/M/L) dB(A) 47/44/43 50/46/43 58/53/48 59/53/49 60/55/51
Main unit dimensions (H/W/D) mm 256/840/840 256/840/840 319/840/840 319/840/840 319/840/840
Weight kg 20 20 24 24 24
Panel dimensions (H/W/D) mm 30/950/950 30/950/950 30/950/950 30/950/950 30/950/950
Panel weight kg 4.2 4.2 4.2 4.2 4.2
Outdoor unit
Compressor type DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5
Standard / Min. pipe length m 7.5 / 5 7.5 / 5 7.5 / 5 7.5 / 5 7.5 / 5
Max. pipe total length m 30 30 50 50 50
Maximum height difference m 30 30 30 30 30
Outer dimensions (H/W/D) mm 550/780/290 550/780/290 890/900/320 890/900/320 1340/900/320
Weight kg 40 44 68 68 99
Standard air flow (Fan unit) m3/h 2400 2700 4080 4200 6180
Sound pressure level, Cooling/Heating*2 dB(A) 46/48 48/52 53/54 54/55 51/53
Sound power level, Cooling/Heating dB(A) 63/65 65/69 70/71 70/71 68/70
Operating range, Cooling/Heating °C -15~46 / -15~15 -15~43 / -15~15
*1 Rated conditions Cooling : Indoor air temperature 27oC DB / 19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB / 6oC WB
*2 Sound pressure levels measured in an anechoic chamber
10

Slim duct type


Slim design for greater application flexibility

Function design

Only 210 mm in height for greater application flexibility.


RAV-SMxx4SDT-E
4-step static pressure setup.
Concealed installation within a ceiling void.
Auxiliary fresh air intake available.

210m m
210m m

Slim & quiet

Quiet, powerful operation.

Perfect comfort throughout the room and can be used with any
style of air diffuser.

Options

Auxiliary fresh air flange


TCB-FF101URE2
11

Technical specifications
Indoor unit (RAV-) SM304SDT-E SM404SDT-E SM564SDT-E
Standard (RAV-) SM304ATP-E SM404ATP-E SM564ATP-E
Outdoor Light Anti-Corrosion protection (RAV-) - - -
unit
Heavy Anti-Corrosion protection (RAV-) SM304ATJP-E SM404ATJP-E SM564ATJP-E
Power supply 1-phase 50Hz 220–240V / 1-phase 60Hz 220V
Capacity kW 2.5 3.6 5.0
Range, min-max kW 0.9-3.0 0.9-4.0 1.5-5.6
Power consumption kW 0.56 0.93 1.91
Cooling*1
Capacity 100% 4.46 3.87 2.62
EER
(Energy Capacity 80% 4.55 4.17 3.28
Efficiency Ratio)
Capacity 50% 4.17 4.74 4.24
Capacity kW 3.4 4.0 5.3
Range, min-max kW 0.8-4.5 0.8-5.0 1.5-6.3
Power consumption kW 0.86 0.97 1.50
Heating*1
Capacity 100% 3.95 4.12 3.53
COP
(Coefficient of Capacity 80% 4.12 4.71 3.96
Performance)
Capacity 50% 4.72 5.71 4.82
Indoor unit
Standard air flow (H/M/L) m3/h 660/560/480 690/600/522 780/678/582
External static pressure-Standard (Upper-Lower) Pa 5-15-30-45 5-15-30-45 4-14-29-44
Sound pressure level-Under air inlet dB(A) 39/36/33 39/36/33 45/40/36
Sound pressure level-Back air inlet dB(A) 30/28/26 30/28/26 33/31/28
Sound power level (H/M/L) dB(A) 54/51/48 54/51/48 60/55/54
Dimensions (H/W/D) mm 210/845/645 210/845/645 210/845/645
Weight kg 22 22 22
Outdoor unit
Compressor type DC rotary DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø9.5 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4
Standard / Min. pipe length m 7.5 / 2 7.5 / 2 7.5 / 5
Max. pipe total length m 20 20 30
Maximum height difference m 10 10 30
Outer dimensions (H/W/D) mm 550/780/290 550/780/290 550/780/290
Weight kg 33 39 40
Standard air flow (Fan unit) m3/h 1800 2200 2400
Sound pressure level, Cooling/Heating*2 dB(A) 46/47 49/50 46/48
Sound power level, Cooling/Heating dB(A) 61/62 64/65 63/65
Operating range, Cooling/Heating °C -15~46 / -15~24 -15~46 / -15~15
*1 Rated conditions Cooling : Indoor air temperature 27oC DB / 19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB / 6oC WB
*2 Sound pressure levels measured in an anechoic chamber
12

Standard duct type


Wide range of application opportunities

Compact sizing

Compact size especially in height (275 mm), new slimmer chassis offers wide range of
RAV-SMxxx6BTP-E installation opportunities to customer.

High static pressure

External static pressure can be raised as high as 120 Pa, so that all areas of the room can
be reached for even temperature distribution, no matter how complex the layout.

Flexible duct is accessible, Allows complete design flexibility

Polygonal rooms Narrow rooms Rooms with fixtures


and obstacles
New spigot shaped flange as new accessories

New spigot shaped flange has higher static pressure with optimized
design, the static pressure drops only 20Pa from rectangle flange states.
Maximum Static pressure will be 100Pa* with all models.
(*static pressure with filter which included in, and intake from back ward)

Options

694
TCB-SF56C6BPE
TCB-SF80C6BPE
TCB-SF160C6BPE

9 94

4
139

(Unit:mm)
13

Technical specifications
Indoor unit (RAV-) SM566BTP-E SM806BTP-E SM1106BTP-E SM1406BTP-E SM1606BTP-E
Standard (RAV-) SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E
Outdoor Light Anti-Corrosion protection (RAV-) - - - - SM1603ATZ-E
unit
Heavy Anti-Corrosion protection (RAV-) SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E
Power supply 1-phase 50Hz 220–240V / 1-phase 60Hz 220V 1-phase 50Hz 230V (220-240V)

Capacity kW 5.0 6.7 10.0 12.1 14.0


Range, min-max kW 1.5-5.6 1.5-7.4 3.0-11.2 3.0-13.2 3.0-16.0
Power consumption kW 1.83 2.38 3.14 4.42 5.13
Cooling*1
Capacity 100% 2.73 2.82 3.18 2.74 2.73
EER
(Energy Capacity 80% 3.42 3.53 3.92 3.46 3.48
Efficiency Ratio)
Capacity 50% 4.39 5.08 4.90 4.92 4.24
Capacity kW 5.3 7.7 11.2 12.8 16.0
Range, min-max kW 1.5-6.3 1.5-9.0 3.0-12.5 3.0-16.0 3.0-18.0
Power consumption kW 1.62 2.32 2.99 3.55 4.69
Heating*1
Capacity 100% 3.27 3.32 3.75 3.61 3.41
COP
(Coefficient of Capacity 80% 3.69 3.87 4.15 4.11 4.04
Performance)
Capacity 50% 4.57 5.07 5.09 4.89 4.32
Indoor unit
Standard air flow (H/M/L) m3/h 798/630/480 1200/930/720 2100/1650/1260 2100/1650/1260 2100/1650/1260
External static pressure (factory setting) Pa 30 30 50 50 50
External static pressure-Standard (Upper-Lower) Pa 30(120-30) 30(120-30) 50(120-30) 50(120-30) 50(120-30)
Sound pressure level (H/M/L) dB(A) 33/29/25 34/30/26 40/36/33 40/36/33 40/36/33
Sound power level (H/M/L) dB(A) 48/44/40 49/45/41 55/51/48 55/51/48 55/51/48
Dimensions (H/W/D) mm 275/700/750 275/1000/750 275/1400/750 275/1400/750 275/1400/750
Weight kg 23 30 40 40 40
Outdoor unit
Compressor type DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5
Standard / Min. pipe length m 7.5 / 5 7.5 / 5 7.5 / 5 7.5 / 5 7.5 / 5
Max. pipe total length m 30 30 50 50 50
Maximum height difference m 30 30 30 30 30
Outer dimensions (H/W/D) mm 550/780/290 550/780/290 890/900/320 890/900/320 1340/900/320
Weight kg 40 44 68 68 99
Standard air flow (Fan unit) m3/h 2400 2700 4080 4200 6180
Sound pressure level, Cooling/Heating*2 dB(A) 46/48 48/52 53/54 54/55 51/53
Sound power level, Cooling/Heating dB(A) 63/65 65/69 70/71 70/71 68/70
Operating range, Cooling/Heating °C -15~46 / -15~15 -15~43 / -15~15
*1 Rated conditions Cooling : Indoor air temperature 27oC DB / 19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB / 6oC WB
*2 Sound pressure levels measured in an anechoic chamber
14

Ceiling type
Smooth curve design & Low noise level

Smooth Curve for pliant Shape


All-new chassis and new rounded design, This new models have been developed in
RAV-SMxxx7CTP-E response to customers’ needs for ceiling units that better match their room interiors.

New Designed Wide Flap Comfortable ambience


The new air oulet has realized both High noise reduction New an has adopted the turbulence prevention rib to optimize the ventilating way.
and large air volume. Air volume has increased and noise level also has decreased compared with previous
model. Winds of new ceiling type of 4HP to 6HP can be reached up to 4.3 metre.
Previous model New model Temperature measuring section Previous model New model
8m
8m

Center 3m

8m
8m

30% Extension
3m
0.5m above the floor

Temperature (deg.C)

Flap control 10 16 22 28 34 (C)

The airflow angle is automatically set to the most New Drain pump kit available as an option
suitable setting according to your cooling or heating
needs, and an automatic swing mode enables airflow The Drain pump kit makes draining easier. Glass built into
to reach all areas of the room to create a comfortable Drain Pump Kit helps reduce mould formation.
ambience.

Options
Options
TCB-KP13CE, TCB-KP23CE
Elbow piping

RBC-AX33CE
Wireless remote controller

TCB-DP31CE
Drain pump kit

TCB-PCUC1E
Optional connecting kit
15

Technical specifications
Indoor unit (RAV-) SM407CTP-E SM567CTP-E SM807CTP-E SM1107CTP-E SM1407CTP-E SM1607CTP-E
Standard (RAV-) SM404ATP-E SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E
Outdoor Light Anti-Corrosion protection (RAV-) - - - - - SM1603ATZ-E
unit
Heavy Anti-Corrosion protection (RAV-) SM404ATJP-E SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E
Power supply 1-phase 50Hz 220–240V / 1-phase 60Hz 220V 1-phase 50Hz 230V (220-240V)

Capacity kW 3.6 5.0 6.9 10.0 12.1 14.0


Range, min-max kW 0.9-4.0 1.5-5.6 1.5-7.4 3.0-11.2 3.0-13.2 3.0-16.0
Power consumption kW 0.83 1.61 2.38 3.11 4.42 4.65
Cooling*1
Capacity 100% 4.34 3.11 2.90 3.22 2.74 3.01
EER
(Energy Capacity 80% 4.65 3.88 3.58 3.96 3.46 3.48
Efficiency Ratio)
Capacity 50% 5.29 5.00 5.23 4.95 4.92 4.32
Capacity kW 4.0 5.3 7.7 11.2 12.8 16.0
Range, min-max kW 0.8-5.0 1.5-6.3 1.5-9.0 3.0-12.5 3.0-16.0 3.0-18.0
Power consumption kW 0.78 1.36 2.13 2.94 3.43 4.61
Heating*1
Capacity 100% 5.13 3.90 3.62 3.81 3.73 3.47
COP
(Coefficient of Capacity 80% 5.93 4.37 4.22 4.23 4.27 3.81
Performance)
Capacity 50% 7.14 5.30 5.42 5.14 5.08 5.00
Indoor unit
Standard air flow (H/M/L) m3/h 900/720/540 900/720/540 1410/1002/750 1860/1350/1020 2040/1530/1200 2040/1650/1260
Sound pressure level (H/M/L) dB(A) 37/35/28 37/35/28 41/36/29 44/38/32 46/41/35 46/42/36
Sound power level (H/M/L) dB(A) 52/50/43 52/50/43 56/51/44 59/53/47 61/56/50 61/57/51
Dimensions (H/W/D) mm 235/950/690 235/950/690 235/1270/690 235/1586/690 235/1586/690 235/1586/690
Weight kg 23 23 29 35 35 35
Outdoor unit
Compressor type DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5
Standard / Min. pipe length m 7.5 / 2 7.5 / 5 7.5 / 5 7.5 / 5 7.5 / 5 7.5 / 5
Max. pipe total length m 20 30 30 50 50 50
Maximum height difference m 10 30 30 30 30 30
Outer dimensions (H/W/D) mm 550/780/290 550/780/290 550/780/290 890/900/320 890/900/320 1340/900/320
Weight kg 39 40 44 68 68 99
Standard air flow (Fan unit) m3/h 2200 2400 2700 4080 4200 6180
Sound pressure level, Cooling/Heating*2 dB(A) 49/50 46/48 48/52 53/54 54/55 51/53
Sound power level, Cooling/Heating dB(A) 64/65 63/65 65/69 70/71 70/71 68/70
Operating range, Cooling/Heating °C -15~46 / -15~24 -15~46 / -15~15 -15~43 / -15~15
*1 Rated conditions Cooling : Indoor air temperature 27oC DB / 19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB / 6oC WB
*2 Sound pressure levels measured in an anechoic chamber
16

High wall type


RAV-SMxx6KRT-E Elegant and slim

Slim-line design

With is attractive, slim-line design, the unit can easily blend in with any room interior.
The filtration system further the indoor air quality benefits of this high wall unit.

Optinum air distribution

RAV-SMxx7KRTP-E 70° directional Auto-swing louvre mode allows optimum air distribution throughout
the room. Total comfort is granted, thanks also to Automatic air volume control and
Automatic cooling/heating.

Cooling mode

Heating mode

Cooling

SWING

Self cleaning function


Toshiba’s self-cleaning function is designed to reduce the humidity that causes mold to
form inside an air-conditioning unit 20 minutes of fan operation after shut down dries
the moist air and helps reduce mold formation on heat exchanger coils.

Normal Operation
Moisture stays trapped inside

Self-cleaning Function
20 minutes of fan operation after shut down dries
the moist air and helps reduce mold formation on
heat exchanger coils.
17

Technical specifications
Indoor unit (RAV-) SM307KRTP-E SM407KRTP-E SM566KRT-E SM806KRT-E
Standard (RAV-) SM304ATP-E SM404ATP-E SM564ATP-E SM804ATP-E
Outdoor Light Anti-Corrosion protection (RAV-) - - - -
unit
Heavy Anti-Corrosion protection (RAV-) SM304ATJP-E SM404ATJP-E SM564ATJP-E SM804ATJP-E
Power supply 1-phase 50Hz 220–240V / 1-phase 60Hz 220V
Capacity kW 2.5 3.6 5.0 6.7
Range, min-max kW 0.9-3.0 0.9-4.0 1.5-5.6 1.5-7.0
Power consumption kW 0.61 1.13 1.66 2.44
Cooling*1
Capacity 100% 4.10 3.19 3.01 2.75
EER
(Energy Capacity 80% 4.17 3.47 3.77 3.44
Efficiency Ratio)
Capacity 50% 3.91 4.19 4.90 4.93
Capacity kW 3.4 4.0 5.3 7.7
Range, min-max kW 0.8-4.5 0.8-5.0 1.5-6.3 1.5-9.0
Power consumption kW 0.85 1.12 1.55 2.61
Heating*1
Capacity 100% 4.00 3.57 3.42 2.95
COP
(Coefficient of Capacity 80% 4.18 4.10 3.85 3.44
Performance)
Capacity 50% 4.72 5.00 4.82 4.48
Indoor unit
Standard air flow (H/M/L) m3/h 516/414/300 516/414/300 840/750/660 1020/750/660
Sound pressure level (H/M/L) dB(A) 40/34/29 41/36/30 42/39/36 47/41/36
Sound power level (H/M/L) dB(A) 55/49/44 56/51/45 57/54/51 62/56/51
Dimensions (H/W/D) mm 275/790/217 275/790/217 320/1050/228 320/1050/228
Weight kg 10 10 12 12
Outdoor unit
Compressor type DC rotary DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø9.5 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4 ø15.9 / ø9.5
Standard / Min. pipe length m 7.5 / 2 7.5 / 2 7.5 / 5 7.5 / 5
Max. pipe total length m 20 20 30 30
Maximum height difference m 10 10 30 30
Outer dimensions (H/W/D) mm 550/780/290 550/780/290 550/780/290 550/780/290
Weight kg 33 39 40 44
Standard air flow (Fan unit) m3/h 1800 2200 2400 2700
Sound pressure level, Cooling/Heating*2 dB(A) 46/47 49/50 46/48 48/52
Sound power level, Cooling/Heating dB(A) 61/62 64/65 63/65 65/69
Operating range, Cooling/Heating °C -15~46 / -15~24 -15~46 / -15~15
*1 Rated conditions Cooling : Indoor air temperature 27oC DB / 19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB / 6oC WB
*2 Sound pressure levels measured in an anechoic chamber
18

Concealed Duct High Static Pressure type

Satisfies all your design needs

Design flexibility

Compatible with externa static pressures up to 196 Pa.

3-steps-switchable static pressure

Low Middle High


RAV-SMxxx2DT-E External static pressure (Pa) 68.6 137.0 196.0

*Factory setting : 137Pa

Large air volume, Duct high static pressure type is most suitable for the large rooms.
Long-life filters fitted as standard. Can be equipped with the following options:

high-efficiency filter (65, 90)


drain pump kit.

Construction characteristics
The flexible duct is accessible. Constant temperature setting is possible in large rooms
or factories. Easy service and installation. Enable to maintain the blower section from
unit side for maintenance and repair. Drain pump kit is available as optional parts up
to 330 mm from unit bottom. Enable to select auto restart operation (set from wired
remote controller)

Options

Filter chamber
TCB-FCY100DE

TCB-PF3DE

TCB-UFM3DE
Drain pump kit
TCB-DP32DE TCB-UFH7DE
19

Technical specifications
Indoor unit (RAV-) SM2242DT-E SM2802DT-E
Standard (RAV-) SM2244AT8-E SM2804AT8-E
Outdoor Light Anti-Corrosion protection (RAV-) - -
unit
Heavy Anti-Corrosion protection (RAV-) - -
Power supply 3-phase 50Hz 380–415V
Capacity kW 20.0 23.0
Range, min-max kW 9.8-22.4 9.8-27.0
Power consumption kW 7.20 8.75
Cooling*1
Capacity 100% 2.78 2.63
EER
(Energy Capacity 80% 3.15 3.24
Efficiency Ratio)
Capacity 50% 3.75 4.49
Capacity kW 22.4 27.0
Range, min-max kW 9.8-25.0 9.8-31.5
Power consumption kW 6.49 8.15
Heating*1
Capacity 100% 3.45 3.31
COP
(Coefficient of Capacity 80% 3.96 3.80
Performance)
Capacity 50% 4.98 4.77
Indoor unit
Standard air flow at 137Pa / (at Mid tap) m3/h 3600 4200
External static pressure (H/M/L) Pa 196/137/68.6
Sound pressure level dB(A) 54 55
Sound power level dB(A) 74 75
Dimensions (H/W/D) mm 470/1380/1250
Weight kg 160
Outdoor unit
Compressor type DC twin rotary
Connecting pipe dia., Gas/Liquid side mm ø28.6 / ø12.7
Min. pipe length m 7.5
Max. pipe total length m 70
Maximum height difference m 30
Outer dimensions (H/W/D) mm 1540/900/320
Weight kg 134
Standard air flow (Fan unit) m3/h 7998 9000
Sound pressure level, Cooling/Heating*2 dB(A) 56/57 57/58
Sound power level, Cooling/Heating dB(A) 72/74 74/75
Operating range, Cooling/Heating °C -15~46 / -20~15
*1 Rated conditions Cooling : Indoor air temperature 27oC DB / 19oC WB, Outdoor air temperature 35oC DB
Heating : Indoor air temperature 20oC DB, Outdoor air temperature 7oC DB / 6oC WB
*2 Sound pressure levels measured in an anechoic chamber
20

Twin system
Cooling Capacity EER Heating Capacity COP
Outdoor unit Indoor unit
Indoor unit type HP
(RAV-) (RAV-) Rated min-max Power consumption 100% 80% 50% Rated min-max Power consumption 100% 80% 50%
(kW) (kW) (kW) (kW) (kW) (kW)
Compact 4-way cassette SM1104AT(J)P-E SM564MUT-E 4 10.0 3.0-11.2 3.16 3.16 3.90 4.85 11.2 3.0-13.0 2.99 3.75 3.96 4.82
SM1104AT(J)P-E SM564UTP-E 4 10.0 3.0-11.2 3.02 3.31 4.08 5.10 11.2 3.0-13.0 2.93 3.82 4.23 5.19
4-way cassette SM1404AT(J)P-E SM804UTP-E 5 12.0 3.0-13.2 4.29 2.80 3.53 5.00 12.8 3.0-16.0 3.40 3.76 4.30 5.12
SM1603AT(Z)(ZG)-E SM804UTP-E 6 14.0 3.0-16.0 4.49 3.12 3.98 4.86 16.0 3.0-18.0 4.43 3.61 4.59 4.91
Digital Inverter 1-phase

Slim duct SM1104AT(J)P-E SM564SDT-E 4 10.0 3.0-11.2 3.18 3.14 3.88 4.81 11.2 3.0-12.5 2.99 3.75 4.15 5.09
SM1104AT(J)P-E SM566BTP-E 4 10.0 3.0-11.2 3.14 3.18 3.92 4.90 11.2 3.0-12.5 2.99 3.75 4.15 5.09
Standard duct SM1404AT(J)P-E SM806BTP-E 5 12.1 3.0-13.2 4.42 2.74 3.46 4.92 12.8 3.0-16.0 3.55 3.61 4.11 4.89
SM1603AT(Z)(ZG)-E SM806BTP-E 6 14.0 3.0-16.0 5.13 2.73 3.48 4.24 16.0 3.0-18.0 4.69 3.41 4.04 4.32
SM1104AT(J)P-E SM567CTP-E 4 10.0 3.0-11.2 3.11 3.22 3.96 4.95 11.2 3.0-12.5 2.94 3.81 4.23 5.14
Ceiling SM1404AT(J)P-E SM807CTP-E 5 12.1 3.0-13.2 4.42 2.74 3.46 4.92 12.8 3.0-16.0 3.43 3.73 4.27 5.08
SM1603AT(Z)(ZG)-E SM807CTP-E 6 14.0 3.0-16.0 4.65 3.01 3.48 4.32 16.0 3.0-18.0 4.61 3.47 3.81 5.00
SM1104AT(J)P-E SM566KRT-E 4 10.0 3.0-11.2 3.13 3.19 3.94 4.90 11.2 3.0-12.5 2.99 3.75 4.15 5.09
High wall SM1404AT(J)P-E SM806KRT-E 5 12.1 3.0-13.0 4.71 2.57 3.25 4.62 12.8 3.0-16.0 3.80 3.37 3.85 4.57
SM1603AT(Z)(ZG)-E SM806KRT-E 6 14.0 3.0-16.0 5.10 2.75 3.22 3.93 16.0 3.0-18.0 4.98 3.21 3.37 3.60
SM2244AT8(Z)(ZG)-E SM1104UTP-E 8 20.0 9.8-22.4 6.24 3.21 3.63 4.33 22.4 9.8-25.0 5.82 3.85 4.42 5.57
SM2244AT7(Z)(ZG) SM1104UTP-E 8 20.0 9.8-22.4 6.24 3.21 3.63 4.33 22.4 9.8-25.0 5.82 3.85 4.42 5.57
4-way cassette
SM2804AT8(Z)(ZG)-E SM1404UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79 27.0 9.8-31.5 7.48 3.61 4.15 5.21
Digital Inverter BIG 3-phase

SM2804AT7(Z)(ZG) SM1404UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79 27.0 9.8-31.5 7.48 3.61 4.15 5.21
SM2244AT8(Z)(ZG)-E SM1106BTP-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
SM2244AT7(Z)(ZG) SM1106BTP-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
Standard duct
SM2804AT8(Z)(ZG)-E SM1406BTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 27.0 9.8-31.5 7.92 3.41 3.91 4.91
SM2804AT7(Z)(ZG) SM1406BTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 27.0 9.8-31.5 7.92 3.41 3.91 4.91
SM2244AT8(Z)(ZG)-E SM1107CTP-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
SM2244AT7(Z)(ZG) SM1107CTP-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
Ceiling
SM2804AT8(Z)(ZG)-E SM1407CTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 27.0 9.8-31.5 7.92 3.41 3.91 4.91
SM2804AT7(Z)(ZG) SM1407CTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 27.0 9.8-31.5 7.92 3.41 3.91 4.91

Triple system
Cooling Capacity EER Heating Capacity COP
Outdoor unit Indoor unit
Indoor unit type HP
(RAV-) (RAV-) Rated min-max Power consumption 100% 80% 50% Rated min-max Power consumption 100% 80% 50%
(kW) (kW) (kW) (kW) (kW) (kW)
Digital Inverter 1-phase

Compact 4-way cassette SM1603AT(Z)(ZG)-E SM564MUT-E 6 14.0 3.0-16.0 4.99 2.81 3.29 4.02 16.0 3.0-18.0 4.69 3.41 4.04 4.32
4-way cassette SM1603AT(Z)(ZG)-E SM564UTP-E 6 14.0 3.0-16.0 4.49 3.12 3.98 4.86 16.0 3.0-18.0 4.43 3.61 4.59 4.91
Slim duct SM1603AT(Z)(ZG)-E SM564SDT-E 6 14.0 3.0-16.0 4.99 2.81 3.29 4.02 16.0 3.0-18.0 4.69 3.41 4.72 4.32
Standard duct SM1603AT(Z)(ZG)-E SM566BTP-E 6 14.0 3.0-16.0 5.13 2.73 3.48 4.24 16.0 3.0-18.0 4.69 3.41 4.04 4.32
Ceiling SM1603AT(Z)(ZG)-E SM567CTP-E 6 14.0 3.0-16.0 4.65 3.01 3.48 4.32 16.0 3.0-18.0 4.61 3.47 3.81 5.00
High wall SM1603AT(Z)(ZG)-E SM566KRT-E 6 14.0 3.0-16.0 5.10 2.75 3.22 3.93 16.0 3.0-18.0 4.98 3.21 3.37 3.60
SM2244AT8(Z)(ZG)-E SM804UTP-E 8 20.0 9.8-22.4 6.24 3.21 3.63 4.33 22.4 9.8-25.0 5.82 3.85 4.42 5.57
SM2244AT7(Z)(ZG) SM804UTP-E 8 20.0 9.8-22.4 6.24 3.21 3.63 4.33 22.4 9.8-25.0 5.82 3.85 4.42 5.57
4-way cassette
SM2804AT8(Z)(ZG)-E SM804UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79 27.0 9.8-31.5 7.48 3.61 4.15 5.21
SM2804AT7(Z)(ZG) SM804UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79 27.0 9.8-31.5 7.48 3.61 4.15 5.21
SM2244AT8(Z)(ZG)-E SM806BTP-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
Digital Inverter BIG 3-phase

SM2244AT7(Z)(ZG) SM806BTP-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
Standard duct
SM2804AT8(Z)(ZG)-E SM806BTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 27.0 9.8-31.5 7.92 3.41 3.91 4.91
SM2804AT7(Z)(ZG) SM806BTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 27.0 9.8-31.5 7.92 3.41 3.91 4.91
SM2244AT8(Z)(ZG)-E SM807CTP-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
SM2244AT7(Z)(ZG) SM807CTP-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
Ceiling
SM2804AT8(Z)(ZG)-E SM807CTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 27.0 9.8-31.5 7.92 3.41 3.91 4.91
SM2804AT7(Z)(ZG) SM807CTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 27.0 9.8-31.5 7.92 3.41 3.91 4.91
SM2244AT8(Z)(ZG)-E SM806KRT-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 3.93
SM2244AT7(Z)(ZG) SM806KRT-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 3.93
High wall
SM2804AT8(Z)(ZG)-E SM806KRT-E 10 23.0 9.8-27.0 9.55 2.41 2.82 3.44 27.0 9.8-31.5 7.92 3.41 3.58 3.84
SM2804AT7(Z)(ZG) SM806KRT-E 10 23.0 9.8-27.0 9.55 2.41 2.82 3.44 27.0 9.8-31.5 7.92 3.41 3.58 3.84
21

Double twin system


Cooling Capacity EER Heating Capacity COP
Outdoor unit Indoor unit
Indoor unit type HP
(RAV-) (RAV-) Rated min-max Power consumption 100% 80% 50% Rated min-max Power consumption 100% 80% 50%
(kW) (kW) (kW) (kW) (kW) (kW)
SM2244AT8(Z)(ZG)-E SM564MUT-E 8 20.0 9.8-22.4 7.12 2.81 3.28 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
Compact 4-way cassette
SM2244AT7(Z)(ZG) SM564MUT-E 8 20.0 9.8-22.4 7.12 2.81 3.28 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
SM2244AT8(Z)(ZG)-E SM564UTP-E 8 20.0 9.8-22.4 6.24 3.21 3.63 4.33 22.4 9.8-25.0 5.82 3.85 4.42 5.57
SM2244AT7(Z)(ZG) SM564UTP-E 8 20.0 9.8-22.4 6.24 3.21 3.63 4.33 22.4 9.8-25.0 5.82 3.85 4.42 5.57
4-way cassette
SM2804AT8(Z)(ZG)-E SM804UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79 2.70 9.8-31.5 7.48 3.61 4.15 5.21
SM2804AT7(Z)(ZG) SM804UTP-E 10 23.0 9.8-27.0 8.19 2.81 3.46 4.79 27.0 9.8-31.5 7.48 3.61 4.15 5.21
SM2244AT8(Z)(ZG)-E SM564SDT-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
Digital Inverter BIG 3-phase

Slim duct
SM2244AT7(Z)(ZG) SM564SDT-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
SM2244AT8(Z)(ZG)-E SM566BTP-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
SM2244AT7(Z)(ZG) SM566BTP-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
Standard duct
SM2804AT8(Z)(ZG)-E SM566BTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 27.0 9.8-31.5 7.92 3.41 3.91 4.91
SM2804AT7(Z)(ZG) SM566BTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 27.0 9.8-31.5 7.92 3.41 3.91 4.91
SM2244AT8(Z)(ZG)-E SM567CTP-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
SM2244AT7(Z)(ZG) SM567CTP-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 5.36
Ceiling
SM2804AT8(Z)(ZG)-E SM807CTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 27.0 9.8-31.5 7.92 3.41 3.91 4.91
SM2804AT7(Z)(ZG) SM807CTP-E 10 23.0 9.8-27.0 9.55 2.41 3.08 4.62 27.0 9.8-31.5 7.92 3.41 3.91 4.91
SM2244AT8(Z)(ZG)-E SM566KRT-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 3.93
SM2244AT7(Z)(ZG) SM566KRT-E 8 20.0 9.8-22.4 7.12 2.81 3.31 4.20 22.4 9.8-25.0 6.40 3.50 4.09 3.93
High wall
SM2804AT8(Z)(ZG)-E SM806KRT-E 10 23.0 9.8-27.0 9.55 2.41 2.82 3.44 27.0 9.8-31.5 7.92 3.41 3.58 3.84
SM2804AT7(Z)(ZG) SM806KRT-E 10 23.0 9.8-27.0 9.55 2.41 2.82 3.44 27.0 9.8-31.5 7.92 3.41 3.58 3.84

Controllers & Accessories


Parts Name Model Name Applied Model Remarks
RBC-AMT32E All indoor units
Wired remote controller RBC-AMS41E All indoor units
RBC-AMS51E-ES/-EN All indoor units

Simple wired remote controller RBC-AS41E All indoor units

RBC-AX32U(W)/(WS)-E 4-way cassette


Controllers Wireless remote controller kits RBC-AX33CE Ceiling
TCB-AX32E2 All indoor units
TCB-EXS21TLE - Use with wired remote controller
TCB-CC163TLE2 - Use with wired remote controller
Remote controller kits
TCB-SC642TLE2 All indoor units
BMS-CM1280TLE All indoor units
TCC-Link adaptor TCB-PCNT30TLE2 All indoor units except High-wall Use with Remote controller kits
Fresh air inlet box TCB-GB1602UE Use with TCB-GFC1602UE
4-way cassette
Fresh air filter chamber TCB-GFC1602UE
4-way cassette, compact 4-way cassette and
Auxiliary fresh air flange TCB-FF101URE2 Slim duct
Spacer for height adjustment TCB-SP1602UE 4-way cassette
Accessories Air discharge direction kit TCB-BC1602UE 4-way cassette
TCB-DP31CE Ceiling Use with TCB-KP13CE, TCB-KP23CE
Drain pump kit
TCB-DP32CE Concealed duct high static pressure
TCB-KP13CE Ceiling
Elbow piping kit
TCB-KP23CE Ceiling
Optional connecting kit TCB-PCUC1E Ceiling
RBC-TWP30E2
Digital Inverter 1-phase model
RBC-TWP50E2
Branch kit RBC-TWP101E "1:2" Twin system of Digital Inverter BIG model
RBC-TRP100E "1:3" Digital Inverter 1-phase model and Digital Inverter BIG model
RBC-DTWP101E "1:4" Double twin system of Digital Inverter BIG model
22

Remote controllers
Lite-Vision plus Remote Controller
Wired remote controller with a built in 7-day timer-featuring a new multi-language,
LCD display with backlight, energy saving options and a return back function.
• Possibility to set and display the room name to easily set-up and monitor the working parameter.
• New modern and desirable controller design with menu driven display.
• Save mode by schedule timer to optimise energy consumption.
• Room temperature display always available.
RBC-AMS51E-ES • Two “Hot Keys” (F1, F2) for easy operation of air conditioner functions.
RBC-AMS51E-EN • Easy to read layout including display of indoor unit model name and serial number.
• Built-in backup power. Settings are kept in memory up to 72 hours in case of power failure.
• Remote TA sensor available in controller.
• Can be connected to a single indoor unit or a group of up to 8 indoor units.

Standard Remote controller Remote controller with weekly timer


Standard wired remote controller can be (7-day timer function)
connected to a single indoor unit or a Wired remote controller with clock display
group of up to 8 indoor units. Power save and a built in 7-day timer function, possible to
operation limits the greatest current value. program 8 functions for each day of the week.
The remote controller allows error to be *The following items can be set in program:
displayed while the protective device works operation time, operation start/stop, operation
RBC-AMT32E or a error occurs. RBC-AMS41E mode, temperature setting, restriction on
button operation

Simple wired remote controller Schedule timer


Simple wired remote controller • Schedule timer mode
can be connected to a single – 6 programmings per day
indoor unit or a group of up to – Enabling 8 groups to be
8 indoor units. programmed
• Start/Stop TCB-EXS21TLE
RBC-AS41E • Temperature setting
• Air flow changing Central remote controller
• Check code display
• Individual control for max. 64 indoor units
divided into 1 to 4 zone (Up to 16 indoor units for
each zone)
Wireless remote controller kit • Up to 16 outdoor header units are connectable
TCB-SC642TLE2 • 4 types of central control settings to inhibit
• Start/Stop individual
• Changing mode operation by remote controller can be selected
• Temperature setting • Usable with other central control devices
• Air flow changing (Max. 10 devices in one control circuit)
• Timer function Either “ON” time or “OFF” time or “CYCLIC” • Two control mode selectivity
can be set how many 30 min. later ON or OFF is operated. (Central controller mode ) Remote controller
• Control by 2 remote controllers is available. mode
Two wireless remote controllers can operate • Setting of simultaneous ON/OFF 3 times per day
one indoor unit. The indoor unit can then be combined with the weekly timer.
operated separately from the two different locations.
• Check code display Central remote controller
• Operation
Individual operation of 128 indoor units available
Return Back Operation
BMS-CM1280TLE Weekly Schedule Operation*
(ON/OFF)
* Schedule timer necessary
RBC-AX32U(W)/(WS)-E RBC-AX33CE • Monitoring
Integral receiver Integral receiver Zone setting (64 zones x 2)
(For 4-way cassette) (For ceiling) Individual unit operation mode operation restriction
Alarm display
Control input
TCB-AX32E2 Status output
Sensor unit; Stand alone receiver
(For 4-way cassette, Compact 4-way cassette (600 ON-OFF controller
x 600), Ceiling, Duct type, High wall)
• Individual control of up to 16 indoor units.
• Setting of simultaneous ON/OFF 3 times
per day combined with the weekly timer.
TCB-CC163TLE2
23

Installation and the use of refrigerants not specified by Toshiba Carrier Corporation

Toshiba refrigeration and air-conditioning units are designed and The type of the refrigerant used for each of our products is shown in the
manufactured on the assumption that the product is used with a accompanying owners manual, or on the product label attached on the
specific refrigerant suitable for each unit. product itself.
We have recently seen some cases where the type of refrigerant Toshiba Carrier Corporation shall not assume any liability for failures,
used is different from the one originally installed in the product. malfunctions or safety in its products if the refrigerant used is different
Such actions may cause mechanical defects, malfunctions, failures from the one specified.
and in some cases result in a serious safety issue. Therefore do
not install any refrigerant other than the one specified by Toshiba
Carrier Corporation for its respective products.

SAFETY PRECAUTIONS

For operation:
• Before use, read through the operating instructions to ensure proper use.
Concerning the purpose for which the air conditioners are to be used
• The air conditioners presented in this catalogue are air conditioning/heating units to be used solely by general consumers.
– Do not use these air conditioners for special applications such as for the storage of food items, animals, plants, precision machines or works
of art. Doing so may degrade the quality of the items.
– Do not use these air conditioners for air-conditioning applications in vehicles or ships. Doing so may cause water and/or power leakages.

Precautions for using air conditioners

Concerning the automatic defrosting unit • Locations where power is supplied from independent power
When the outdoor air temperature drops, frost may form on the generators. The power line frequency and/or voltage may
heat exchanger of the outdoor unit. In such cases, the automatic fluctuate, possibly causing the air conditioner to malfunction.
defrosting unit will be activated, and it will take 5 to 8 minutes for the • L ocations where high frequencies or electrical noise is
heating operation to be restored. generated (from high-frequency welders used for vinyl welding
and processing, high-frequency therapeutic devices used
Concerning the air conditioner's operating conditions and their for thermotherapy, etc.) The electronic components may be
selection adversely affected, possibly causing the air conditioner to
(1) Avoid using the air conditioner in the following locations. malfunction.
• Locations with acidic or alkaline atmospheres (locations at which • Locations where electronic equipment is installed. Electrical
highly acidic or alkaline air is directly drawn in, such as in hot noise may adversely affect the operation of the electronic
springs areas from which sulfur gases are given off, or where equipment.
chemicals, vinegar, exhaust air from burners, etc., are given off )
The heat exchangers and other parts may become corroded. (3) Concerning use in locations with high ceilings
• Locations with atmospheres filled with coolant or other machine • In locations with high ceilings, use of circulators for improving
oil or steam exhaust (such as at food preparation factories or the temperature distribution during heating is recommended.
machine plants). The heat exchangers may corrode; frost may
form as a result of heat exchanger malfunction; air conditioner (4) Concerning use in high-humidity environments
operating performance may be compromised or condensation • When the ceiling-recessed type of indoor unit is installed in a
may form as a result of clogged filters; plastic parts may incur location, such as those described below, and it is very hot and
damage; heat-insulation materials may become separated, etc. humid inside the ceiling, condensation may form on the external
surfaces of the indoor unit and drip down. In such cases, add
(2) Before using an air conditioner in any of the following locations, external heat-insulating materials.
consult with your dealer or a qualified contractor. – Locations such as food preparation sites in which the areas
• Locations where vapors from edible oils are given off (such above the ceilings are hot and humid
as in bakeries or kitchens and restaurants that use edible – Locations in which outside air is drawn in and routed above the
oils) ...The air conditioner's operating performance may be ceiling
compromised or condensation may form as a result of clogged – A bove ceilings with a slate roof or tiled roof overhead
filters, and the plastic parts may incur damage. In line with the
prevailing conditions, take countermeasures such as tailoring the (5) Even when an air conditioner is shut down, it will still consume a
installation conditions in accordance with the conditions, using small amount of power to protect the unit. If the air conditioner
air conditioners designed for kitchens or oil guard filters, etc. will not be used for a prolonged period, turn OFF the main switch
• Locations with disinfectant-induced chlorine atmospheres (water (ground fault circuit breaker). However, before the unit is to be
tanks, etc.) The metal parts in the heat exchangers, motors, etc.,
used again, turn ON the main switch (ground fault circuit breaker)
may become corroded.
• L ocations with high salinity (coastal areas, etc.) Corrosion for at least 12 hours in order to prevent trouble.
may occur so use outdoor units specifically designed to
withstand exposure to salt.
T201601-LC-DI

You might also like