You are on page 1of 9

ERRATA SHE

Module Name: RCC Chapter 1 Question

No. Page No. Que No.

1 1 3

2 1 3

3 1 5

4 1 5

5 2 8

6 2 10 (2)

7 2 13

8 3 15

9 3 16

10 3 22
ERRATA SHEET
tion Proof-reading done by: Mrs Rashmi Gupta

Error Correction to be made


List-I contains some properties of concrete cement and List-II
Group-I contains some properties of
concrete/ cement and Group-II

List-I Group-I
A. Workability of commie A. Workability of concrete
B.Direct tensile strength of coma-etc B.Direct tensile strength of concrete
List-II Group-II
1. Cylinder splitting lest 1. Cylinder splitting test
2. Tiee-Bee test 2. Vee-Bee test
5. Pull out. Lest 5. Pull out test

partial material safely factor (yn) for steel according partial material safety factor (yn) for steel
to IS: 436-2000 is according to IS: 456-2000 is
b)1.13 b)1.15

is not more than ∓ Y 5 percent is not more than ∓ Y percent


Water is added to the concrete mix for
Water is added to the for hydration of workability hydration of cement and workability

according to IS 45 6:2000 is according to IS 456:2000 is


a) 50000 fck b) 0.7 fck a) 5000 fck b) 0.7 fck
c) 50000√Fck d) 0.7 √Fck c) 5000√fck d) 0.7 √fck

List - I List - I
C. Split cylinder teat C. Split cylinder test
D. Compacting factor lest D. Compacting factor test

the Limit State Design of a flexural


the Limit Suite Design of a flexural member, the swain in member, the strain in reinforcing bars
reinforcing bars under tension at ultimate state should not under tension at ultimate state should not
be haw than be less than
√Fck fck
Rashmi Gupta

Remarks(If any)
ERRATA SHEET
Module Name: RCC Chapter 2 Question

No. Page No. Que No. Error

section is subject to will be eccentric


compression . The neutral axis will be
1 1 1(II) parallel to the resultant axis of banding.
A reinforced con to beam of rectangular
2 1 4 &5 crass section
The spacing (nun) of 2 – legged 8 mm
3 1 4 stirrups 10 be provided Is
environment this her undergoes uniform
corrosion
4 1 7
5 2 7(a) Corrosion onuses circumferential
6 2 7(a) the creeks will be parallel
7 2 7(c) the cracks will he perpendicular
8 2 7(d) causes radial tensile anemia in concrete
9 2 11 (c) missing
RATA SHEET
Proof-reading done by: Mrs Rashmi Gupta

Correction to be made Remarks(If any)

section is subject to biaxially eccentric compression .


The neutral axis will be parallel to the resultant axis
of bending.
A reinforced concrete beam of rectangular cross
section
The spacing (mm) of 2 – legged 8 mm stirrups to be
provided is

environment this bar undergoes uniform corrosion


Corrosion causes circumferential
the cracks will be parallel
the cracks will be perpendicular
causes radial tensile stresses in concrete
(c) grade of concrete only
ERRATA SHEET
Module Name: RCC Chapter 3 Question

No. Page No. Que No. Error


1 1 1 axial load or 450 kN

2 1 1 size 2m × 3m side along the plane


3 1 1 column Centers of gravity
4 1 1 soil under the Coating are
5 1 2&3 The two leads are gradually
6 1 2&3 with 2 HYDC bars

characteristic compressive strength and the


bending tensile strength of the concrete are
7 1 2&3 20.0 N/mm2 and d2.2 N/mm2 respectively
8 1 3(Options ) a) 23.7 EN b) 25.6 KR
9 2 9 & 10 M20 and re250 respectively

10 2 11 Question is incomplete, fig.is missing


11 2 13 Fig. is missing
RRATA SHEET
Proof-reading done by: Mrs Rashmi Gupta

Correction to be made Remarks(If any)


axial load of 450 kN

size 2m × 3m, with 3m side along the plane


column Centres of gravity
soil under the footing are
The two loads are gradually
with 2 HYSD bars

characteristic compressive strength and the bending


tensile strength of the concrete are 20.0 N/mm2 and
2.2 N/mm2 respectively
a) 23.7 kN b) 25.6 kN
M20 and Fe250 respectively

The cross-section at mid- span of a beam at the edge


of a slab is shown in the sketch. A portion of the slab
is considered as the effective flange width for the
beam. The grades of concrete and reinforcing steel
are M25 and Fe415 respectively. The total area of
reinforcing bars (A) is 4000 mm2 . At the ultimate
limit state xu denotes the depth of the neutral axis
from the top fibre. Treat the section as under-
reinforced and flanged (xu > 100mm)
Module Name: RCC Chapter 4
0.87fySv ERRATA SHEET

No. Page No. Que No. Error


ERRATA SHEET
Proof-reading done by: Mrs Rashmi Gupta

Correction to be made Remarks(If any)

You might also like