Fire and Smoke Curtains

Table of Content
Company Profile 4

Introduction 6
The Concept
Products Functions
Advantage vs. others
Gravity Fail Safe
Area of use

American Products 12
SmokeStop™ D100 Deployable Smoke & Draft Curtain
®
FireMaster D200 Fire & Smoke Rated Curtain
® ®
FireMaster evacU8 D200E Fire & Smoke Rated Curtain
With Egress

European Products 21
SmokeStop™ Smoke Barriers
®
SmokeStop™ evacU8 Smoke Barriers
®
FireMaster Fire Curtain Barriers
®
FireMaster Horizontal Fire Barriers
®
FireMaster Concertina™ Fire Curtains Barriers

Optional Extra Control Features 40


Test & Certification Bodies 41
Matrix Table American Vs European 42
Case Studies 43
Projects Reference List 48
3
COMPANY PROFILE
With Over 35 years of commitment to the region, SMC interiors has positioned itself as
a market leader in the manufacture and supply of quality interior finishing products.

SMC interiors’ primary clientele is the contract market, focusing mainly on sectors such as
hospitals, office buildings, hotels, universities, airports, governmental Institutions, commercial
centers and high-end private residences/palaces. Major projects have included Al-Immam
Mohammed Bin Saud Islamic University in Riyadh, which called for the manufacture of over
260,000 square meters of false ceilings; considered to be the largest single metal false
ceiling supply contract in the world. Other iconic projects include Al Faisaliah Center, Kingdom
Tower, King Saud University (KSU) and Princess Noura bint Abdulrahman University (PNU) in
Riyadh, King Abdullah University of Science and Technology (KAUST) in Thuwal, Haram Car
Parking Extension in Madinah, Aramco North Park in Dahran, Bahrain Financial Harbour-Dual
Towers and the Dubai Police Head Quarters.

With regional expansion set as a strategic goal; SMC interiors currently has physical presence
in six geographical areas; Jeddah, Riyadh, Al-Khobar, Bahrain, Dubai and Abu Dhabi; in
addition to sister companies based in Jordan and Lebanon. Furthermore, in order to assure
continuous growth; the management is committed to long-term strategic investments in the
areas of Machinery, IT Solutions and most importantly Human Resources.

SMC interiors’ leadership is also highlighted by our relentless thrive to making international
standards locally available. This is highlighted by accreditations and certifications from ISO,
UL, ASTM, GreenGuard Gold; to mention a few.

We aim to offer and develop our products and services to the highest possible standards in
order to assure your success and the long-term viability of our relationships.

We thank you for your trust and aim to continuously exceed your expectations.

Sincerely,


Peter I. Kildani
President

4
MOTTO
Widening the gap one step at a time

VISION
To be recognized as the market leader in providing the
optimum solution for interior finishing products

MISSION
Create demand and loyalty by sharing our passion,
integrity and desire to continuously exceed expectations

5
Smoke and Fire Barriers
Introduction

The Concept

Smoke Barriers: Fire Curtain Barriers:


Smoke Barriers control the movement of fire Active Fire Curtain Barrier assemblies used in life
effluent within a construction works in the safety and property protection applications can
event of fire. Smoke barriers, when used within be vertical, horizontal or angled. For example,
a smoke and heat control system, become a these could be used in place of fire doors and
critical element of that system. If smoke barriers shutters, non-load bearing walls, non-load
are not in their fire operational position, the bearing ceilings and glazing. They can be used to
system will not perform as designed. However, form fire separation, such as protected lobbies.
even in the event that other elements of the The typical advantage of active fire curtain
SHEVS do not function, smoke barriers in the assemblies is that they enable greater width
fire operational position will provide essential and curtain movements with smaller space
smoke containment and channelling. requirement than other traditional methods,
e.g. steel fire shutters, doors.

6
Products Functions
• To stop rapid spread of smoke throughout the building.
• Assist occupants with safe evacuation.
• Assist emergency services.
• Fire and smoke containment.
• Used as a life safety product.

Advantage vs. Others


Being the original patent holders of this technology, the fail-safe by gravity feature presents
itself as a testament to SMC Coopers Fire status as the market leader in Fire and Smoke Barriers
with continuous research & development keep on widening the gap one step at a time.

Gravity Fail-Safe
The concept to SMC Coopers gravity fail-safe “Property of a fire/smoke/draft curtain barrier
assembly to move to it’s fire operational position in a safe and controlled manner to facilitate fire/
smoke separation when all consumable primary and auxiliary power supplies are removed, in the
event of wiring or system corruption, open or short circuit, or any combination thereof.” It shall do
so in a safe and controlled manner.

7
Area of Use:
Void Edges - Compartments & Channelling - Lift Lobbies – Car Parks – Escalators - Service
Hatches - Atriums – Auditoriums – Theatres - Warehouses - Service Corridors – Factories
Containment – Protection For Non Fire Rated Glazing - & Etc…

Void Edges:

Non fire rated glass on the main entrance Smoke Barriers to protect the entrance

Lift Lobby Application:

Fire Curtain Barriers forming protected lift lobby

8
Compartmentation and Channelling:

Smoke Barriers are not visible

Smoke Barriers Partial Containment

9
Car Park Application:

Fire Curtain Barriers to protect Car Park

Escalator:

Fire Curtain Barriers for Escalators

10
Serving Hatches:

Fire Curtain Barriers used within service hatch opening

Angled Boundaries:

Fire Curtain Barriers for Boundary Protection in front of non-fire rated glazing

11
American Products

SmokeStop™ D100 Deployable Smoke


& Draft Curtains
Description
SMC Coopers deployable smoke & draft curtains are like a large electrically operated roller blind.
Whereby they are concealed above a ceiling out of view. The curtains are either activated by an
alarm signal or by a power outage. The fabric is fire resistant, but the system as a whole is not
meant to stop fire; it instead impedes or channels out the smoke.

The SMC Coopers SmokeStop ™ D100 is manufactured from the same materials that has been
tested and certified for a 3-Hour fire label and smoke and draft rating, approved to span unlimited
widths and heights up to 9m. The test criteria for fire rated assemblies included side guides,
however the design parameters for deployable smoke & draft curtains do not require any of the
above certifications except the ability to impede the spread of smoke and therefore side guides are
not required for the D100 Deployable Smoke Draft Curtains . Thus, the D100 Smoke Draft Curtain
exceeds the fire and life safety requirements of the building code.

Deployment Options

12
Product Application
A Smoke Draft Curtain is commonly used in large spaces where smoke management is a challenge.
In these type of applications, Smoke Draft Curtains typically work in conjunction with smoke and
heat vents. Above smoke movement provides temporary tenable environments until building
occupants can evacuate during a fire or emergency. Smoke Draft Curtains are a critical part of the
compartmentalization effort because they prevent the migration of smoke and help to channel it
towards vents that are a passive system for smoke management.

Product Advantages
SMC Coopers SmokeStop™ D100 are made of technologically advanced fire-resistant fabric. The
assembly is concealed in a compact overhead housing and is virtually invisible when retracted.
Operated by remotely located control unit and fully synchronized with the building fire and life
safety system. Upon activation the assembly gravity drops into place and is automatically reset after
clearing of the fire alarm or smoke detection system.

Applicable Standards
• International Building Code (IBC), Chapter 9, Section 910.3.5.1
• UL 10B:2009, Standard for Fire Tests of Door Assemblies (without hose steam)
• UL 10C:2009, Standard for Positive Pressure Fire Tests of Door Assemblies (without hose steam)
• UL 10D:2009, Outline Investigation for Fire Tests for Fire Protective Curtains
• UL 1784:2004, Standard for Air Leakage Tests of Door Assemblies
• UL 864:2003, Standard for Control Units and Accessories for Fire Alarm Systems

Certification
• Listing & Labelling with Intertek (ITS)
• BS EN ISO 9001:2008 with British Standards Institute (BSI)
• BS EN ISO 14001:2004 with Lloyds Register (LRQA)

13
SmokeStop™ D100 Deployable Smoke & Draft
Curtains Maximum Sizes
• Single roller: width up to 5m, heights up to 9m
• Multiple rollers: width unlimited*, heights up to 9m
• N.B: In Multiple Rollers fabric overlap is 600mm

Fire Rated
3-Hours Rating up to 1000°C

Box sizes

*For deployable smoke & draft curtains with large widths/heights kindly contact SMC interiors representative

14
FireMaster® D200 Fire & Smoke
Rated Curtains:
Description
The SMC Coopers FireMaster® D200 is a first in the industry. It has been US laboratory tested and
approved for unlimited widths, heights up to 8m with a UL 10B/C rating for 20 minutes, a UL 10D
rating for 3-Hour and is also UL 1784 Smoke & Draft rated.

The SMC Coopers FireMaster® D200 is mounted as a vertical rolling assembly with fixed side
guides to ensure against movement or blowout during extreme pressures caused by fire conditions.
These pressure guides, combined with a specially designed bottom bar, make this fire-rated fabric
assembly a critical component of a building’s passive redundant fire and life safety system. Equipped
with brush stripes in the housing and pressure side guides to meet the requirement of NFPA 105.

Fire & Smoke Rated Curtains

Product Application
SMC Coopers Fire & Smoke Rated Curtains are mainly used in fire compartments or to isolate & stop
the propagation of fire & smoke from one area to another.

In case of a fire, to ensure safe passage of people, FireMaster® D200 Fire & Smoke Rated Curtain
can be used as both a fire and a smoke curtain; thanks to the Split Drop Delay option. It can be
programmed to deploy in a smoke operational position for a certain period of time, which would in
turn allow people to escape.

15
Product Advantages
The SMC Coopers FireMaster® D200 is made of a technologically advanced fire-resistant fabric.
The assembly is concealed in a compact overhead housing and is virtually invisible when in the
retracted position. Operated by remotely located control unit and fully synchronized with the
building fire and life safety system. The SMC Coopers FireMaster® D200 uses the same features as
other SMC Coopers Fire Curtain Systems.

Upon activation, the assembly gravity drops in a controlled manner into place and is automatically
reset after clearing of the fire alarm or smoke detection system. The SMC Coopers FireMaster®
D200 fire and smoke rated curtains are available with Oversize Certification to span unlimited
widths.

Applicable Standards
• International Building Code (IBC), Chapter 7, Section 715.4.2, Table 715.4
• UL 10B:2009, Standard for Fire Tests of Door Assemblies (without hose steam)
• UL 10C:2009, Standard for Positive Pressure Fire Tests of Door Assemblies (without hose steam)
• UL 10D:2009, Outline Investigation for Fire Tests for Fire Protective Curtains
• UL 1784:2004, Standard for Air Leakage Tests of Door Assemblies
• UL 864:2003, Standard for Control Units and Accessories for Fire Alarm Systems

Certification
• Listing & Labelling with Intertek (ITS)
• BS EN ISO 9001:2008 with British Standards Institute (BSI)
• BS EN ISO 14001:2004 with Lloyds Register (LRQA)

16
FireMaster® D200 Fire & Smoke Rated Curtains
Maximum Sizes
• Single roller: width up to 5m, heights up to 8m
• Multiple Roller: width unlimited*, heights up to 8m.
• N.B: In Multiple Rollers fabric overlap is 600mm.

Fire Rated
3-Hour Fire Rating up to 1000°C

Box sizes

*For FireMaster® D200 Fire & Smoke Rated Curtains with large widths/heights kindly contact
SMC interiors representative

17
FireMaster® evacU8® D200E Fire &
Smoke Rated Curtain With Egress:
Description
The SMC Coopers FireMaster® evacU8® D200E is a fire and smoke rated curtain with soft surface
egress doors. The SMC Coopers FireMaster® evacU8® D200E is a first in the industry, made of a
flexible fire-resistant fabric that has been US laboratory tested and approved for up to widths up
to18m, heights up to 6m. It has a UL 10B/C rating for 20 minutes, and UL 10D for 90 minutes and
is also UL 1784 Smoke & Draft rated.

The SMC Coopers FireMaster® evacU8® D200E incorporates a new concept in egress doors, the
soft-surface egress door can be pushed open with less than 30 pounds of force applied to the
interior surface, once opened a building occupant can easily pass through for egress. This swinging
technology also allows the soft-surface egress door to automatically return to its fully closed fire
and life safety position.

ADA Compliant

Product Application
The SMC Coopers FireMaster® evacU8® D200E, shown above depicts a single fire and smoke rated
assembly which can incorporate egress doors. The D200E when deployed is fixed in vertical high
pressure side guides that are easily hidden by side mounting. This technology guarantees no blowout
or movement problems that are a potential challenge with combustion during a fire. Because D200E
will not blowout from vertical shaft air pressures that are common in multistory buildings, these
assemblies are easily tested under normal building conditions.

18
Product Advantages
The assembly is concealed in a compact overhead housing and is virtually invisible when in the
retracted position. Operated by a remotely located control unit and fully synchronized with
the building fire and life safety system, The FireMaster ® evacU8® D200E uses the same self-
closing features as other SMC Coopers Fire Curtain systems. Upon activation the assembly
gravity closes in a controlled manner into place and is automatically reset after clearing of the
fire alarm or smoke detection system.

Applicable Standards
• International Building Code (IBC), Chapter 7, Section 715.4.2, Table 715.4 and Chapter 10,
Section 1008.1.3 and 1008.1.9
• UL 10B:2009, Standard for Fire Tests of Door Assemblies (without hose steam)
• UL 10C:2009, Standard for Positive Pressure Fire Tests of Door Assemblies (without hose steam)
• UL 10D:2009, Outline Investigation for Fire Tests for Fire Protective Curtains
• UL 1784:2004, Standard for Air Leakage Tests of Door Assemblies
• UL 864:2003, Standard for Control Units and Accessories for Fire Alarm Systems

Certification
• Listing & Labelling with Intertek (ITS)
• BS EN ISO 9001:2008 with British Standards Institute (BSI)
• BS EN ISO 14001:2004 with Lloyds Register (LRQA)

19
FireMaster® evacU8® D200E With Egress
Maximum Sizes
• Single roller: width up to 18m*, height up to 6m*
• Only single roller available

Fire Rated
90 min fire rating up to1000ºC

Box Sizes

Maximum Width <5 metres Maximum Width > 5 metres < 18 meters Maximum Width <5 metres Maximum Width > 5 metres < 18 meters
Maximum Drop <4 metres Maximum Drop <4 metres Maximum Drop > 4 metres < 6 meters Maximum Drop > 4 metres < 6 meters

*For FireMaster® evacU8® D200E Fire & Smoke Rated Curtains with large widths/heights kindly
contact SMC interiors representative

• The maximum width for a single motor is 5m span, beyond this we use a further motor at the
opposite end
• The door is secured at the side with hook and loop and a ‘breakable’ bottom bar section

20
European Products

Smoke Barriers:
Description
Smoke Barriers are like a large electrically operated roller blind. Whereby they are concealed above
a ceiling out of view. The barriers are either activated by an alarm signal or by a power outage. The
fabric is fire resistant, but the system as a whole is not meant to stop fire; it instead Impedes or
channels out the smoke.

Deployment Options

21
Product Application
Smoke and heat exhausted ventilation systems (SHEVS) create a smoke free layer above the floor
by removing smoke and heat, and thus improve the conditions for the safe escape and/or rescue of
people and animals and the protection of property and permit the fire to be fought while still in its
early stages.

Smoke barriers control the movement of fire effluent within a construction works in the event of
fire. Smoke barriers, when used within a smoke and heat control system, becomes a critical element
of that system if smoke barriers are not in their fire operational position, the system will not perform
as designed. However, even in the event that other elements of the SHEVS do not function smoke
barriers in the fire operational position will provide essential smoke containment and channelling.

Product Advantages
Smoke Barriers are made of technologically advanced fire-resistant fabric. The assembly is
concealed in a compact overhead housing and is virtually invisible when retracted.

Operated by remotely located control unit and fully synchronized with the building fire and life
safety system. Upon activation the assembly gravity drops into place and is automatically reset after
clearing of the fire alarm or smoke detection system.

Applicable Standards
• BS EN 12101-1:2005+A1:2006, Smoke and heat control systems. Specification for smoke
barriers
• BS EN 1363-1:1999, Fire resistance tests. General requirements
• BS EN 1634-3:2004, Fire resistance and smoke control tests for door and shutter assemblies, openable
windows and elements of building hardware. Smoke control test for door and shutter assemblies
• BS EN 13501-4:2007+A1:2009, Fire classification of construction products and building elements.
Classification using data from fire resistance tests on components of smoke control systems
• BS EN ISO 1716:2010, Reaction to fire tests for products. Determination of the gross heat of
combustion (calorific value)
• BS EN 13823:2010, Reaction to fire tests for building products. Building products excluding
floorings exposed to the thermal attack by a single burning item
• BS EN 13501-1:2007+A1:2009, Fire classification of construction products and building
elements. Classification using test data from reaction to fire tests
• BS 476-6:1989+A1:2009, Fire tests on building materials and structures. Method of test for
fire propagation for products
• BS 476-7:1987, Fire tests on building materials and structures. Method for classification of the
surface spread of flame of products
• BS 6323-5:1982, Specification for seamless and welded steel tubes for automobile, mechanical
and general engineering purposes. Specific requirements for electric resistance welded
(including induction welded) steel tubes
• BS EN ISO 9001:2008, Quality management systems
• BS EN ISO 14001:2004, Environmental management systems

22
Certification
• CE Marking & Labelling with International Fire Consultants Certification (IFCC)
• Independent Third Party Product Certification to ISO Guide 65 with International Fire
Consultants Certification (IFCC)
• BS EN ISO 9001:2008 with British Standards Institute (BSI)
• BS EN ISO 14001:2004 with Lloyds Register (LRQA)

Smoke Barriers Maximum Sizes


• Single roller: width up to 8m, heights up to 8m
• Multiple rollers: width unlimited*, heights up to 10.5m
• N.B: In Multiple Rollers fabric overlap is 400mm

Classification
• DH60: ≤ 60 min following time temperature curve
• D600A: 120+min at 600ºC

Functional Gaps
Functional gaps may be required between the barrier and the construction works, and for angled and
adjacent barriers only. The functional gap allowed is:

• 20mm for barriers which travel up to and including 2m


• 40mm for barriers which travel from 2m up to and including 6m
• 60mm for barriers which travel more than 6m

23
Box Sizes

*For SmokeStop™ Smoke Barriers with large widths/heights kindly contact SMC interiors representative

24
SmokeStop™ evacU8®
Description
SmokeStop™ evacU8® smoke barriers are a unique patented bi-roller system which has narrow
interweaving / overlapped panels which are only 600mm (24”) wide. Each panel overlaps the other
and has its own self-levelling bottom ballast system.

Evacuees can simply WALKTHRUTM the ‘strips’ which then fall back into place, helped by the
patented anti-tangle overlap retention system. The SmokeStop™ evacU8® smoke barrier is also
DDA compliant.

• Total Gravity Fail-Safe Operation, demanded by legislation and only available fully tested and
certified from SMC Coopers Fire
• Patented anti-tangle re-alignment & overlap retention system
• Self-levelling bottom system to overcome uneven floors
• See through overlaps and 50% translucent panels for safety
• Patented strip retraction system to enable safe, consistent retraction
• Unique mechanical over ride system for Emergency Services (Optional)
• Safety Escape System*

*Signage shall be designed to meet the requirements of local regulations in terms of positional
placement, symbols, language and colour.

Deployment Options

Standard Deployment

Full deployment provides total smoke


protection whilst still allowing WALKTHRUTM

25
Multistage Deployment

1. Partial closure of all fabric strips provides


initial smoke layer depth protection whilst
allowing clear WALKTHRUTM

2. Further full closure of alternate fabric strips


creates clear escape routes

3. Full closure of remaining fabric strips provides


total smoke protection whilst still allowing
WALKTHRUTM

Product Application
• The ever increasing need for both damage prevention and occupant safety
• Prevents smoke spreading quickly, threatening life or damaging buildings & contents
• Intuitive means of escape
• Quick and easy, minimal effort, DDA compliant
• Ideal for high occupancy buildings / high traffic areas
• No delay for escape

26
Common Applications

• Underground Rail Stations


• Airports
• Stadiums
• Museums
• Office Blocks
• Cinemas
• Shopping Centres
• Libraries
• Universities
• Hospitals
• Schools
• Restaurants

Applicable Standards
• BS EN 12101-1:2005+A1:2006, Smoke and heat control systems. Specification for smoke barriers
• BS EN 1363-1:1999, Fire resistance tests. General requirements
• BS EN 1634-3:2004, Fire resistance and smoke control tests for door and shutter assemblies, openable
windows and elements of building hardware. Smoke control test for door and shutter assemblies
• BS EN 13501-4:2007+A1:2009, Fire classification of construction products and building elements.
Classification using data from fire resistance tests on components of smoke control systems
• BS EN ISO 1716:2010, Reaction to fire tests for products. Determination of the gross heat of
combustion (calorific value)
• BS EN 13501-1:2007+A1:2009, Fire classification of construction products and building
elements. Classification using test data from reaction to fire tests
• BS 476-6:1989+A1:2009, Fire tests on building materials and structures. Method of test for
fire propagation for products
• BS 476-7:1987, Fire tests on building materials and structures. Method for classification of the
surface spread of flame of products
• BS 6323-5:1982, Specification for seamless and welded steel tubes for automobile, mechanical
and general engineering purposes. Specific requirements for electric resistance welded
(including induction welded) steel tubes
• BS EN ISO 9001:2008, Quality management systems
• BS EN ISO 14001:2004, Environmental management systems

Certification
• CE Marking & Labelling with International Fire Consultants Certification (IFCC)
• Independent Third Party Product Certification to ISO Guide 65 with International Fire
Consultants Certification (IFCC)
• BS EN ISO 9001:2008 with British Standards Institute (BSI)
• BS EN ISO 14001:2004 with Lloyds Register (LRQA)

SmokeStop™ evacU8® Maximum Size


• Single rollers: width up to 5m, heights up to 6.3m
• Multiple rollers: width unlimited*, heights up to 6.3m
• N.B: In Multiple Rollers fabric in min. of 600mm, with overlaps min. 30mm

27
Classification
• D600A: 120+min at 600ºC

Box Size

300mm

200mm

The maximum drop available from this headbox is 4m.


For a drop between 4m and 6m a 350mm x 250mm headbox is required.

Removable
access
Access for maintenance is always required through the bottom of the
headbox along the entire width of the SmokeStop™ evacU8® barrier.

This is achieved by removing the bottom panels on both sides


of the headbox as illustrated above.

28
FireMaster® Active Fire Curtain Barriers:
Description
SMC Coopers FireMaster® Active Fire Curtain Barriers are like a large electrically operated roller
blind. Whereby they are concealed above a ceiling out of view. The curtains are either activated by
an alarm signal or by a power outage. The Fire Curtain Barriers are always installed with side guides
to stop the propagation of fire & smoke from one area to another.

Active Fire Curtain Barriers comprise technologically advanced fire-resistant fabric roller barriers
encased in a compact steel housing. Barriers remain invisibly retracted until activated by an alarm
or detector signal, at which time they descend safely to their operational position. To be regulation
compliant, they must be protected by total power failure Gravity Fail-Safe. The fire curtain is
mounted as a vertical rolling assembly with fixed side guides to ensure against movement or
blowout during extreme pressures caused by fire conditions.

120min or 240min rating of a Fire Curtain is actually for the complete systems ability to stop the
flames and not let the fire pass that barriers location.

Product Application
SMC Coopers FireMaster® Fire Curtain Barriers are used in life safety and property protection
application and can be horizontal, vertical or angled. For example, in certain end-use applications,
these could be used in place of fire doors and roller shutters, non-loadbearing walls, non-loadbearing
ceilings and glazed elements. They can be used to form fire separation, such as protected routes and
protected lobbies. Active fire curtain barrier assemblies can enable greater barrier widths and barrier
movements using less space than other traditional methods.

In case of a fire, to ensure safe passage of people, a Fire Curtain Barrier can be used to contain
smoke for a predetermined time before closing fully for full fire containment, thanks to the Split Drop
Delay, allowing evacuees to escape underneath it. As an additional safety precaution, one can install
an emergency retract button, which when pressed, would pull the curtain upwards and after safely
passing through, the curtain would automatically descend.

29
Product Advantages
When compared to the other fire solutions is that the assembly is concealed in a compact overhead
housing and is virtually invisible when in the retracted position. It is operated by a remotely located
control unit and fully synchronized with the building fire and life safety system. Upon activation the
assembly gravity drops into place and is automatically reset after clearing of the fire alarm or smoke
detection system.

Fire Curtain Barriers Require Side Guides

29

90 - 100
Adjustable

End fixed Face fixed Recessed

30
Applicable Standards
• BSI PAS 121:2007, Specification for active fire curtain barrier assemblies and active fire barrier
assemblies with smoke rating
• BS EN 1634-1:2008, Fire resistance and smoke control tests for door, shutter and, openable
window assemblies and elements of building hardware. Fire resistance tests for doors, shutters
and openable windows
• BS EN 1363-1:1999, Fire resistance tests. General requirements
• BS EN 1363-2:1999, Fire resistance tests. Alternative and additional procedures
• BS EN 13501-2:2007+A1:2009, Fire classification of construction products and building
elements. Classification using data from fire resistance tests, excluding ventilation services
• BS EN 12605:2000, Industrial, commercial and garage doors and gates. Mechanical aspects.
Test methods
• BS EN 14600:2005, Doorsets and openable windows with fire resisting and/ or smoke control
characteristics. Requirements and classification
• BS 476-6:1989+A1:2009, Fire tests on building materials and structures. Method of test for
fire propagation for products
• BS 476-7:1987, Fire tests on building materials and structures. Method for classification of the
surface spread of flame of products
• BS 6323-5:1982, Specification for seamless and welded steel tubes for automobile, mechanical
and general engineering purposes. Specific requirements for electric resistance welded
(including induction welded) steel tubes
• BS EN ISO 9001:2008, Quality management systems
• BS EN ISO 14001:2004, Environmental management systems

Certification
• Independent Third Party Product Certification to ISO Guide 65 with International Fire
Consultants Certification (IFCC)
• Independent Third Party Product Certification to PAS 121:2007 with International Fire
Consultants Certification (IFCC)
• BS EN ISO 9001:2008 with British Standards Institute (BSI)
• BS EN ISO 14001:2004 with Lloyds Register (LRQA)

Fire Curtain Barriers Maximum Sizes


• Single roller: width up to 5m, heights up to 8m
• Multiple rollers 240min fire rated: width up to 44.6m, heights up to 5m
• Multiple rollers 120 mins fire rated: width unlimited*, heights up to 8m
• N.B: In Multiple Rollers fabric overlap is 600mm

31
Classification
• FireMaster® (2h) to EN 1634-1 (E120, EW20)
• FireMaster® (4h) to BS 476-22.8 (240mins)
• FireMaster® Plus to EN 1634-1 (E120 EW60)
• FireMaster® Super Plus™** to EN 1634-1 (El1 120)** With Sprinklers

Box Sizes

*For FireMaster® Fire Curtain Barriers with large widths/heights kindly contact SMC interiors representative.
For specialist products FireMaster® Plus and SuperPlus™ kindly contact SMC interiors representative.

32
FireMaster® Horizontal Active Fire
Curtain Barriers:
Description
SMC Coopers FireMaster® Horizontal Active Curtain Barriers comprise technologically advanced
fire-resistant fabric roller barriers encased in a compact steel housing. Curtains remain invisibly
retracted until activated by an alarm or detector signal. At this time they close safely to their
operational position where they stop and control the spread of fire in a building.

Product Application
The FireMaster® Horizontal Active Curtain Barrier is suitable for large and small openings such as
expansive atriums or it can be used in skylight applications.

Product Advantages
When compared to the other fire solutions is that the assembly is concealed in a compact housing
and is virtually invisible when in the retracted position. It is operated by a remotely located control
unit and fully synchronized with the building fire and life safety system. FireMaster® Horizontal
Active Fire Curtain Barriers use NVS™ technology (no visible supports) within the opening. Thereby
the opening is completely free and clear of any auxiliary slide cables. This is of particular benefit for
building service and maintenance purpose as access equipment can be used through the openings.

33
Applicable Standards
• BSI PAS 121:2007, Specification for active fire curtain barrier assemblies and active fire barrier
assemblies with smoke rating
• BS EN 1634-1:2008, Fire resistance and smoke control tests for door, shutter and, openable
window assemblies and elements of building hardware. Fire resistance tests for doors, shutters
and openable windows
• BS EN 1363-1:1999, Fire resistance tests. General requirements
• BS EN 1363-2:1999, Fire resistance tests. Alternative and additional procedures
• BS EN 13501-2:2007+A1:2009, Fire classification of construction products and building
elements. Classification using data from fire resistance tests, excluding ventilation services
• BS EN 12605:2000, Industrial, commercial and garage doors and gates. Mechanical aspects.
Test methods
• BS EN 14600:2005, Doorsets and openable windows with fire resisting and/ or smoke control
characteristics. Requirements and classification
• BS 476-6:1989+A1:2009, Fire tests on building materials and structures. Method of test for
fire propagation for products
• BS 476-7:1987, Fire tests on building materials and structures. Method for classification of the
surface spread of flame of products
• BS 6323-5:1982, Specification for seamless and welded steel tubes for automobile, mechanical
and general engineering purposes. Specific requirements for electric resistance welded
(including induction welded) steel tubes
• BS EN ISO 9001:2008, Quality management systems
• BS EN ISO 14001:2004, Environmental management systems

Certification
• Independent Third Party Product Certification to ISO Guide 65 with International Fire
Consultants Certification (IFCC)
• Independent Third Party Product Certification to PAS 121:2007 with International Fire
Consultants Certification (IFCC)
• BS EN ISO 9001:2008 with British Standards Institute (BSI)
• BS EN ISO 14001:2004 with Lloyds Register (LRQA)

FireMaster® Horizontal Simplex™ Fire Curtain


Barriers Maximum Sizes
Single Horizontal Size Range:
• Min. width 1.5m, max. width 5m
• Min. length 1.5m, max. length 7m

Manufacturing = 7 meters
Assessed = 12 meters

Manufacturing = 5 meters
Assessed = 5 meters

34
FireMaster® Horizontal Duplex™ Fire Curtain
Barriers Maximum Sizes
Double Horizontal Size Range:
• Min. width 1.5m, max. width 5m
• Min. length 7m, max. length 14m
Manufacturing = 14 meters Assessed = 10 meters

Manufacturing =
5 meters
Assessed =
5 meters

Classification
FireMaster® Horizontal Fire Curtain Barrier E120 EW30
FireMaster® Plus Horizontal Fire Curtain Barrier E120 EW60

Box Sizes
FireMaster® Horizontal Simplex™ Fire Curtain Barriers

For specialist products FireMaster® Plus Horizontal Simplex™ Fire Curtain Barriers kindly contact SMC interiors representative

35
FireMaster® Horizontal Duplex™ Fire Curtain Barriers

36
FireMaster® Concertina™ Active
Fire Curtain Barriers:
Description
SMC Coopers FireMaster® Concertina™ Active Fire Curtain Barriers protects WITHOUT the need for
CORNER POSTS giving architects, consultants and specifiers a whole new way to approach buildings
design. SMC Coopers FireMaster® Concertina™ Active Fire Curtain Barriers provides both 60min
and 180min protection as a revolution in active fire separation. With delayed and/or split drop
deployment, the control system offers safe escape as well as controlled ‘gravity fail-safe’ and auto
retract. This enables easy integration with a dedicated fire alarm system or building management
suite.

Fire Curtain technology is safe and as standard incorporates a ‘total’ fail-safe by gravity system
in the event of total mains, wiring and/or system corruption. Installing a large SMC Coopers
FireMaster® Concertina™ Active Fire Curtain Barriers to replace a non-loadbearing wall opens up
exciting design possibilities for architects and construction engineers. Fire curtains are designed to
activate upon receipt of a signal from either a fire alarm system or locally positioned detector.

Product Application
Design can include the use of escalator and stairwell protection. SMC Coopers FireMaster®
Concertina™ Active Fire Curtain Barriers provide an effective alternative to non-loadbearing fire
walls, or traditional rolling fire shutters and/or fire curtain barriers that are required to terminate
into corner posts of columns, and are used extensively as part of the fire engineered solution in
commercial and industrial applications such as airports, shopping centers, and offices etc, where the
need for maintaining open areas for access is vital.

37
Product Advantages
SMC Coopers FireMaster® Concertina™ Active Fire Curtain Barriers does not require any visible
support posts at the corners. Have unlimited spans and drops of 8m* with a small lightweight
housing.
Can be installed as a polygon, triangle, ‘L’ shaped right angles, curves, ‘Z’ shapes or even in a
complete circle. Act as a fire separating element within the building design to prevent the passage of
fire for a predetermined period of time.

Applicable Standards
• BSI PAS 121:2007, Specification for active fire curtain barrier assemblies and active fire barrier
assemblies with smoke rating
• BS EN 1634-1:2008, Fire resistance and smoke control tests for door, shutter and, openable
window assemblies and elements of building hardware. Fire resistance tests for doors, shutters
and openable windows
• BS EN 1363-1:1999, Fire resistance tests. General requirements
• BS EN 1363-2:1999, Fire resistance tests. Alternative and additional procedures
• BS EN 13501-2:2007+A1:2009, Fire classification of construction products and building
elements. Classification using data from fire resistance tests, excluding ventilation services
• BS EN 12605:2000, Industrial, commercial and garage doors and gates.
Mechanical aspects. Test methods
• BS EN 14600:2005, Doorsets and openable windows with fire resisting and/ or smoke control
characteristics. Requirements and classification
• BS 476-6:1989+A1:2009, Fire tests on building materials and structures. Method of test for
fire propagation for products
• BS 476-7:1987, Fire tests on building materials and structures. Method for classification of the
surface spread of flame of products
• BS 6323-5:1982, Specification for seamless and welded steel tubes for automobile, mechanical
and general engineering purposes. Specific requirements for electric resistance welded
(including induction welded) steel tubes
• BS EN ISO 9001:2008, Quality management systems
• BS EN ISO 14001:2004, Environmental management systems

38
Certification
• Independent Third Party Product Certification to ISO Guide 65 with International Fire
Consultants Certification (IFCC)
• Independent Third Party Product Certification to PAS 121:2007 with International Fire
Consultants Certification (IFCC)
• BS EN ISO 9001:2008 with British Standards Institute (BSI)
• BS EN ISO 14001:2004 with Lloyds Register (LRQA)

FireMaster® Concertina™ Fire Curtain Barriers


Maximum Sizes
• Width unlimited*, heights up to 8m
• “Open system” 60min Fire Rated: width unlimited*, heights up to 8m
• “Closed system” 180min Fire Rated: width unlimited*, heights up to 5m
• N.B. Corner angles between 180 and 90 degrees, fabric overlap 200mm at corners and
600mm in straight lenghts

Classification
• FireMaster® Concertina™ “open system” E60 EW60
• FireMaster® Concertina™ “closed system” E180 EW60

Box Sizes

*For FireMaster® Concertina™ Active Fire Curtain Barrier with large widths/heights kindly contact SMC interiors
representative. With regards to different shapes in plan forming corners/mitres plus termination back to a wall kindly
contact SMC interiors representative.

39
*For FireMaster® Concertina™ Active Fire Curtain Barrier with large widths/heights kindly contact SMC interiors
representative. With regards to different shapes in plan forming corners/mitres kindly contact SMC interiors representative.

Optional Extra Control Features*:

For additional system features kindly contact SMC interiors representative which models these apply to

40
Test and Certification:

41
Matrix Table American Vs European:
Smoke Curtains:

Descriptions American European


Side Guides No Side Guides Optional

Brush Strips (Head Box) Available N/A

Fabric Overlap Multiple Roller 600mm 400mm

Fire Rated 3-Hour D A and DH60


600

Maximum Size Widths unlimited, heights up Widths unlimited, heights up


to 9m to10.5m

Fire Curtains:

Descriptions American European


Side Guides Available Available

Brush Strips Available Available

Fabric Overlap Multiple Roller 600mm 600mm

Fire Rated 3-Hour 120mins and 240min

240min Fire Rate: Width up to


44.6m, heights up to 5m
Maximum Size Width unlimited, heights up
to 8m 120min Fire Rate: Width
unlimited, heights up to 8m

Other Systems:

Descriptions American European


Horizontal N/A Available

Pleated/Folding N/A Available

Mass Egress N/A Available

Limited Egress Available N/A

42
Case Studies:
GREATER LONDON AUTHORITY - GLA BUILDING - LONDON - UK

This new and striking piece of modern architecture,which sits opposite the Tower of London, and
next to Tower Bridge, houses the Mayor of London and his assembly. It provides 17,000 square
metres of accommodation on ten levels.Its glass enclosure invites the public to watch the assembly
at work. The top floor is available for exhibitions or functions for up to 200 people.

The building’s unique,offset spherical design has a built in environmentally sustainable energy
system,which reduces the running costs to 25% of what they would have been using traditional
methods. The cutting edge design also incorporates a natural ventilation system.

Much of the interior is open plan, which necessitated the inclusion of Coopers Fire Barriers at high
level to separate the auditorium from the walkways. The barriers are fitted with voice warning
systems and “split drop”delays,ensuring that upon initiation, the barrier will provide the essential
smoke containment, followed by full fire containment. Coopers also designed and fitted “Bomb
Blast” Barriers in the mail room, separating it from the car park.

43
ROYAL EXCHANGE - LONDON - UK

A landmark site in the City of London,the Royal Exchange is a feat of architecture, which stands
proudly alongside the Bank of England, Mansion House and The Stock Exchange. The third and
current Exchange was designed by Sir William Tite and was originally conceived as a meeting place
for city merchants.It is open to the public on most days.

The building has been twice destroyed by fire, but on both occasions it was re-built on the same
site.The current Royal Exchange was opened by Queen Victoria on January 1st 1845 and cost no
less than £150,000!

As part of a major refurbishment,Coopers designed and installed a series of concealed Fire Barriers
to the ground floor shop fronts, which provide fire and smoke containment in the event of a fire
within a shop. As there is only one point of entry and escape from the shops, all barriers are fitted
with voice warning systems and “split drop”delays.All barriers also have high visibility signage and
emergency retract facilities.

Due to the unique design and application,Coopers worked closely with architects Fitzroy Robinson
& Partners, to satisfy the high level of scrutiny, approvals and testing that are required by the local
authorities.

44
SWISS RE BUILDING - LONDON - UK

Towering majestically above the London skyline, the Swiss Re Building is set to become one of the
capitals most prestigious landmarks. Designed by the eminent architect Lord Foster, and built by
Skanska the Swedish construction company, it will house retail outlets as well as offices,to serve the
local working community.

The aerodynamic form of the building aids the unique natural ventilation system,by minimising
wind loads on the structure, such that wind is not deflected to ground level, where it would cause
discomfort to pedestrians.

Coopers engineers worked closely with Arup Fire Consultancy to design and install over a kilometre
of smoke containment system for numerous floor levels within the thirty nine storey glass tower.
The unique design of the building necessitated a stringent and highly detailed performance
specification to be produced and adhered to. Coopers were chosen for this important project
because of their track record in providing innovative solutions that suit the requirements of modern
building designs and materials.

45
PRINCESS NORA UNIVERSITY

A vision of King Abdullah Bin AbdulAziz Al Saud, Custodian of the Two Holy Mosques to advance
education in the Kingdom of Saudi Arabia, the Princess Nora Bint AbdulRahman University is now a
reality. The 800-ha 3-million msq built up area campus, the largest woman-only university in the
world, was inaugurated by the Custodian of the Two Holy Mosques on 12th of jumada’II, 1432 H
(May 15th, 2011), exactly two years and two months from the date construction contracts were
signed in February 2009.

A substantial site team oversaw implementation directing contractors working on multi-tracks


of different construction phases and dosely supervising work progress. During the months of
construction 75,000 workers, over 225 cranes and in excess of 5,000 construction equipment
worked around the clock to beat the set 25-months construction.

SMC Coopers life safety products have been selected jointly by Dar Al Handasah & Areen Design
Services to be integrating into the PNU Mega Project. SMC Coopers smoke curtains has participated
in achieving the designer life safety evacuation plans.

SMC Coopers Fire & smoke curtains are retracted into a concealed housing in the ceiling and is only
deployed in a fire situation or for testing purposes.
SMC Coopers smoke curtains has been installed as a life safety products in the below locations to
stop the rapid spread of smoke into the buildings, assist occupants with safe evacuation, & assist
emergency service in case of fire:

1. Kitchens: to control the smoke between the kitchens areas & common /classes’ areas.
2. Atriums: to stop the smoke from travelling between different levels of the building.

All the smoke Containment Systems were fully installed, tested, and commissioned by SMC interiors
Saudi – Arabia Fire Specialists.

46
HARAMAIN HIGH SPEED RAIL PROJECT

The Haramain High Speed Rail project also known as the “Western Railway” or “Mecca-Medina high
speed railway”, is a 449.2 kilometres (279.1 mi) high speed inter-city rail transport system under
construction in Saudi Arabia.[1] It will link the Muslim holy cities of Medina and Mecca via King
Abdullah Economic City, Rabigh, Jeddah, and King Abdulaziz International Airport. It will connect with
the national network at Jeddah.

The rail line is planned to provide a safe and comfortable transport in 320 kilometres per hour
(200 mph) electric trains. Construction started in March 2009. The railway is expected to carry
three million passengers a year, including many Hajj and Umrah pilgrims, helping to relieve traffic
congestion on the roads. The double-track line will be electrified and the design speed is 360
kilometres per hour (220 mph).

The total contract value is EUR 6.736 billion (approximately US$9.4 billion).

SMC Coopers specialists in fire and smoke containment were commissioned to produce a custom
designed barrier system to prevent smoke dispersion into the station. The smoke curtains, which
were installed by SMC interiors Saudi Arabia were specifically designed to protect the means of
escape for customers, whilst at the same time dramatically reduce the transmission throughout the
building of life threatening effluent generated by a fire.

SMC Coopers with its unique links with authorities governing fire legislation, such as BSi, has
developed an unprecedented track record for providing highly effective barrier systems for multi-
national companies at prime locations worldwide.

All the smoke Containment Systems were fully installed, tested, and commissioned by SMC interiors
Saudi – Arabia Fire Specialists.

47
PROJECTS REFERENCE LIST:

Buildings of National Interest

• Buckingham Palace, UK

• National Theatre, UAE

• St. James Palace, UK

• European Parliament Building, Belgium

• Hong Kong Conference Ct, Hong Kong

• Sydney Opera House, Australia

• King Abdullah Waqf Project, Madinah, Saudi Arabia

• DOKAAE, Makkah, Saudi Arabia

• KFU Central Library, Dammam, Saudi Arabia

• Jabal Al Kaba Hotel Project, Jeddah, Saudi Arabia

• King Abdullah Financial, Riyadh, Saudi Arabia

• National Theatre, Manama, Bahrain

• Al Rayassa Building, Madinah, Saudi Arabia

• B.A.T., Southampton

• B.O.C, Newbury

• Coca Cola, Belgium

• JCB, Cheadle

• Martin Dawes Telecom, Warrington

• Motorola, Swindon

• Proctor & Gamble, Belgium

• RAF, Wattisham

• Rover Plant, Gaydon

• Smithkline Beecham, Harlow

• Stella Artios, Belgium

• Sun Micro, Farnborough

• Quran Warehouse, Madinah, Saudi Arabia

• Sabic Plastic Applications Development Center Building, Riyadh, Saudi Arabia

Offices

• Canary Wharf, London, UK

• NCM, Cardiff, UK

• St. Catherine’s, London, UK

• Standard Life, Edinburgh, UK

48
Banks
• Belgium Bank, Hong Kong
• Credit Suisse, Canary Wharf, UK
• International Finance Centre, UAE
• Royal Bank Of Scotland, Edinburgh, UK
• Lehman Brothers, Canary Wharf, UK
• Morgan Stanley, Canary Wharf, UK
• HSBC, Canary Wharf, UK

Universities & Colleges

• KSAU (King Saud Abdulaziz University for Health & Science), Riyadh, Saudi Arabia

• KSAU (King Saud Abdulaziz University for Health & Science), Jeddah, Saudi Arabia

• KSU (King Saud University), Riyadh, Saudi Arabia

• Princess Noura University (PNU), Riyadh, Saudi Arabia


• New University Project in Jeddah, Jeddah, Saudi Arabia

Airports

• Ataturk, Turkey

• Birmingham, UK

• Brisbane, Australia

• Chek Lap Kok, Hong Kong

• Dubai International Terminal 3, UAE

• Dulles International, USA

• Düsseldorf, Germany

• Gatwick, UK

• Heathrow, UK

• Johannesburg, South Africa

• Luton, UK

• Manchester, UK

• Preswick, Scotland, UK

• Stanstead, UK

• Zaventem, Belgium

49
Railway Stations

• Kowloon, Hong Kong

• Royal Mail, Willesden, UK

• Tsing Yi, Hong Kong

• Harmain High Speed Railway Station, Jeddah, Saudi Arabia

Shopping Centres

• Arndale, Manchester, UK

• Bentalls, Kingston, UK

• Bluewater Park, Dartford, UK

• Braehead, Glasgow, UK

• Buchannan Galleries, Glasgow, UK

• Castle Mall, Norwich, UK

• Dubai Mall, UAE

• Harlequin, Watford, UK

• Lakeside, Thurrock, UK

• Mall of Emirates, UAE

• Meadowhall, Sheffield, UK

• Merryhill, Dudley, UK

• Oracle, Reading, UK

• Overgate, Glasgow, UK

• Trafford Centre, Manchester, UK

• West Quay, Southampton, UK

• Paris Gallery - City Center, Bahrain

• Lunar Exhibition Floor (Makkah Clock), Makkah, Saudi Arabia

Sports Arenas

• Wembley National Stadium, UK

• Liverpool FC, Bolton Wanderers FC, Arsenal FC (football stadiums)

• Aquatic Centre, Olympic Village London, UK

50
PDF Version of this catalog can be downloaded from:
http://www.smcinteriors.com/catalog/SmokeFireCurtains.pdf
E-Catalog Version of this catalog can be downloaded from:
http://www.smcinteriors.com/catalog/SmokeFireCurtains

This document is protected in law under International Copyright Law. Reproduction, distribution, display and use of this document without written permission from SMC is prohibited.
SMC has a policy of continuous improvement. As such we reserve the right to change design and specifications without prior notice. Please check our website for the latest information.
Jeddah Head Office Riyadh Al Khobar
t +966 12 637 6069 t +966 11 463 0770 t +966 13 894 5480
f +966 12 636 5433 f +966 11 463 1742 f +966 13 894 2893
p.o.box 13018 Jeddah 21493 p.o.box 50091 Riyadh 11523 p.o.box 79765 Khobar 31952

Bahrain Dubai Abu Dhabi


t +973 17 310 567 t +971 4 364 9440 t +971 2 643 0211
f +973 17 310 678 f +971 4 364 9441 f +971 2 643 0212
p.o.box 18379 Manama p.o.box 74261 Dubai p.o.box 130209 Abu Dhabi www.smcinteriors.com