Hydro-Tower

Minimal space requirement - maximal system efficiency


Buffer tank and hot water cylinder Combination tank with integrated heat pump manager

The required heating water flow must be guaranteed in all The HWK 332 Econ Hydro Tower provides the complete heat
operating conditions for trouble-free operation of the heat pump. pump hydraulic system in the smallest of spaces, as it
In addition, the volume of hot water circulated must be combines a heat pump manager, a hot water buffer tank and a
sufficiently large to prevent cycle operation with short buffer tank connected in series as well as optimised pump units
compressor runtimes occurring. For this reason, the generator in one compact and space-saving casing. It can easily be
and consumer circuits are often hydraulically decoupled and a connected to an air-to-water heat pump installed outside via two
buffer tank connected in series is installed for expanding the hydraulic connecting lines and one electrical connecting cable.
circulated volume of the system. A separate cylinder requiring The integrated components for an unmixed heating circuit with
additional space is necessary for domestic hot water a circulating pump each in the generator circuit and the
preparation. consumer circuit ensure the required heating water flow and
secure trouble-free operation.
HWK 332 Econ for LA 9TU, LA 12TU and LA 17TU

✔ High degree of operational safety thanks to buffer tank


connected in series and dual differential pressureless
manifolds (DDV)

✔ 300 l hot water cylinder with 3.15 m² heat exchanger area


for a high degree of comfort when it comes to hot water
preparation

✔ Electronically regulated circulating pump with efficiency


rating A for an unmixed consumer circuit

✔ WPM EconPlus heat pump manager with ready-for-use


circulating pumps, sensors and heating elements
connected

✔ Hydraulic connection of the heat pump possible from the


right, left or behind

The simple and quick way to ready-to-use hydraulics

The Hydro Tower is connected to an air-to-water heat pump


installed outside via two hydraulic connecting lines and one
electrical connecting cable. All electrical components such as
circulating pumps, sensors and heating elements are connected
to the heat pump manager ready to use, meaning that only the
supply voltage has to be connected by an electrician.

Hydro Tower with integrated heat pump manager

Order reference HWK 332 Econ HWK 332


Part number 361460 362360
Regulation WPM EconPlus Integrated none
Connection voltage Regulation V 230 230
Connection voltage V 230 / 400 230 / 400
Width x Height x Depth mm 740 x 1920 x 950 740 x 1920 x 950
Weight kg 205 202
Buffer tank volume l 100 100
Hot water cylinder volume l 277 277
Hot water cylinder heat exchanger area m² 3,15 3,15
Heating connection inch 1 1/4" FD 1 1/4" FD
Hot water connection inch 1" AG 1" AG
Expansion vessel connection inch 1" FD 1" FD
Heat circulating pump Integrated (Efficiency rating A) Integrated (Efficiency rating A)
Auxiliary circulating pump Integrated Integrated
Hot water circulating pump Integrated Integrated
Flange heater Integrated Integrated
2nd heat generator pipe heater Integrated (2/4/6 switchable) Integrated (2/4/6 switchable)

DDV - Energy saving hydraulics


The integrated circulating pump for the manifold circuit adjusts the delivery volume and thus the electrical energy used to the heat
consumption and complies with energy efficiency rating A. The hydraulic decoupling is done via two differential pressureless
manifolds (bypass pipes), each fitted with a check valve. The circulating pump in the generator circuit is only operated when the
compressor is running to reduce the runtimes. In one year, this saves approximately 2000 operating hours.

Glen Dimplex Deutschland GmbH Subject to change and errors!