You are on page 1of 2

LPG SERIES-GEL Battery

LPG12-200 (12V200AH)
Specification
Nominal Voltage 12V
Nominal Capacity(20HR) 200.0AH
Length 522 3mm (20.55 inches)
Width 240 3mm (9.45 inches)
Dimension
Container Height 218 3mm (8.58 inches)
Total Height (with Terminal) 224 3mm (8.81 inches)
Approx Weight Approx 62.9 kg (138.7lbs)
Terminal T11
Container Material ABS
200.0 AH/10.0A (20hr,1.80V/cell,250C/770F)
186.0 AH/18.6A (10hr,1.75V/cell,250C/770F)
Rated Capacity 160.0 A H/32.0A (5hr,1.75V/cell,250C/770F)
139.2 AH/46.4A (3hr,1.75V/cell,250C/770F) Applications
110.0 AH/110.0A (1hr,1.67V/cell,250C/770F)
Max. Discharge Current 1800A (5s) Telecommunications
Internal Resistance Approx 3.24mÙ Solar system
0 0
Discharge : -20 55 C (-4 131 F) Wind power system
Operating Temp.Range Charge : 0 400C (32 1040F ) Wheelchair
Storage : -20 500C (-4 1220F)
Floor cleaning machines
Nominal Operating Temp. Range 25 30C (77 50F )
Golf trolley
Initial Charging Current less than 50.0A.Voltage
Cycle Use Boats
14.4V~15.0V at 250 C(770 F)Temp. Coefficient -30mV/0C
No limit on Initial Charging Current Voltage
Standby Use
13.5V~13.8V at 250 C(770 F)Temp. Coefficient -20mV/0C
40o C (104o F) 103%
Capacity affected by
25o C ( 77o F) 100%
Temperature VdS
0o C ( 32o F) 86%
Leoch LPG series batteries may be stored for up to 9 months
Self Discharge at 250 C(770F) and then a freshening charge is required. t est ed
For higher temperatures the time interval will be shorter. 9 Germany

0 0
Constant Current Discharge (Amperes) at 25 C (77 F )
F.V/Time 20min 30min 45min 1h 2h 3h 4h 5h 6h 7h 8h 9h 10h 20h
1.85V/cell 169.2 132.8 101.3 84.8 53.8 41.0 34.0 29.3 25.3 22.4 20.2 18.5 17.5 9.60
1.80V/cell 193.8 148.4 111.7 93.6 58.2 43.9 36.0 30.8 26.6 23.5 21.2 19.4 18.2 10.0
1.75V/cell 217.8 163.2 120.8 100.2 61.7 46.4 37.7 32.0 27.5 24.3 21.9 20.0 18.6 10.2
1.70V/cell 234.6 174.8 128.3 106.0 65.4 48.3 39.0 33.0 28.5 25.1 22.5 20.5 19.0 10.3
1.67V/cell 244.2 181.6 132.8 110.0 67.1 49.9 39.9 33.7 28.9 25.5 22.9 20.8 19.3 10.4
1.60V/cell 264.6 194.4 142.7 116.8 69.8 51.9 41.4 34.7 29.6 26.0 23.3 21.2 19.6 10.6

Constant Power Discharge (Watts/cell) at 25 0C (77 0F )


F.V/Time 20min 30min 45min 1h 2h 3h 4h 5h 6h 7h 8h 9h 10h 20h
1.85V/cell 323.8 255.9 196.5 165.1 105.1 80.3 66.8 57.9 50.1 44.5 40.2 36.8 34.8 19.2
1.80V/cell 366.1 283.3 215.1 181.3 113.3 85.8 70.5 60.6 52.4 46.4 42.0 38.6 36.3 19.9
1.75V/cell 406.9 308.7 230.8 193.1 119.6 90.4 73.6 62.7 54.1 47.9 43.3 39.7 37.0 20.3
1.70V/cell 433.5 327.8 243.3 203.1 126.2 93.9 75.9 64.5 55.9 49.4 44.5 40.7 37.8 20.5
1.67V/cell 446.2 337.0 250.2 209.6 128.8 96.4 77.5 65.7 56.7 50.0 45.1 41.1 38.2 20.7
1.60V/cell 478.1 357.3 266.8 221.3 133.4 99.8 80.2 67.5 57.8 51.0 45.8 42.0 38.9 21.0
Specifications subject to change without notice.

1
Dimensions

T11 Terminal 522 2


Unit: mm [inches] 500 2
20 [0.787]
M8 [0.315]
6[0.236]

224 2

240 2
140 2
218 2

Discharge Characteristics Float Charging Characteristics


CHARGE CHARGING CHARGING
VOLUME CURRENT VOLTAGE
Temperature 250C % (A)
13.0 (V/cell) 0.1CA-2.25V/cell Temperature(250C
120
12.0 0.1C 2.4
100 CHARGED VOLUME
Terminal Voltage(V)

11.0 80 0.08C 2.3


0.1C 0.05C CHARGE VOLTAGE
0.2C (Constant 2.25v/cell)
0.4C
10.0 0.6C 60 0.06C 2.2
AFTER 50% DISCHARGE
2C 1C

9.0 40 0.04C 2.1 AFTER 100% DISCHARGE

C=C20
8.0 20 0.02C 2.0
C=C20
CHARGING CURRENT

0 0C
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20
min H 0 4 8 12 16 20 24 28 32

Discharge Time Charging Time (hours)

Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life
110

100
14
Life expectancy(year)

12
90
Available capacity / %

Charging voltage
10
80 2.25V/cell

70
5
60

C20
50 2
C10
C5
40 C3
C1
30 0.5
-20 -15 -10 -5 0 5 10 15 20 25 30 20 30 40 50 O0 C
68 86 104 122 F
Battery temperature/¡æ Battery temperature

Cycle Life in Relation to Depth of Discharge General Relation of Capacity VS. Storage Time
0 0
Acc.to IEC 896-2 (25 C / 77 F)
100 Residual average capacity in % of C20
120
90
Extracted capacity in %

80
100
70
Available capacity %

80
60
10
50
60
40 30
40 20
30 40

20
20
10

400 800 1200 1600 2000 2400 2800 3200 3600 4000 0 5 10 15 20 25

Number of Cycles Storage time in month

Sales Office
China sales office: HongKong sales office: Singapore sales office: North America sales office: Europe sales office:
Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Add: Workshop C, 33/F, TML Tower, Add: No. 1 Tech Park Crescent, Add: 19751 Descartes, Unit A, Add: 9B Wheatstone Court. Waterwells
Nanshan,Shenzhen, China. 518052 No. 3 Hoi Shing Road, Tsuen Wan, Singapore 638131 Foothill Ranch, CA 92610, USA Business Park, Gloucester, GL2-2AQ,
Tel:+ 86-755-86036060 (100 lines) New Territories, Hong Kong Tel: +65 68416629 Tel: 949-588-5853 UK United Kingdom