On systems using door leaves that are narrow and thick and the hypotenuse is more than
SF4-50
the door width x 1.004 then a risk of camming exists (see diagram 12).
43 45
*For doors between 35-44mm an alternative to the Securefold flushbolt is required.
**For thicker or thinner doors please contact PC Henderson Technical Department
technical@pchenderson.com
SF1-50
SF2-50
SF4-50
SF7-50
SF1-50 SF7-50
INSIDE OUTSIDE
SF2-50
Diagram 2
JAMB CAP
IN LINE WITH
TRACK
SF7-50 SF7-50
Diagram 3
SF7-50
SF7-50
Diagram 4
SF4-50 SF2-50
SF1-50
SF1-50 SF2-50
SF4-50
140
SF9
JAMB CAP IN LINE WITH TRACK
JAMB CAP GASKET
52 39
212
ALTERNATIVE ALUMINIUM THRESHOLD SF94T
SUPPLIED BY PCH - COMES COMPLETE
WITH 94P AND ENDCAPS AND IS PREDRILLED
FOR DRAINAGE. REFER TO PAGE 9
INTERMEDIATE
2 HANGER SET KIT
SF4-50
PREPARATION
END HANGER SET KIT
SF1-50 - Pivot Assembly Set PIVOT SET KIT SF2L-50
SF1-50 SF2R-50
SF2R-50 - End Hanger Set Right Hand
SF2L-50 - End Hanger Set Left Hand
SF3-50 - Hinge Set with Handle
SF4-50 - Intermediate Hanger Set SF9
(OPTIONAL)
SF5-50 - Hinge Set Inward Opening
SF6-50 - Hinge Set Offset Inward Opening
SF7-50 - Hinge Set Offset Outward Opening
SF8-50 - Rebated End Hanger Meeting
SF9 - Pivot Hinge for Doors Over 2200mm High (Optional) Diagram 5
SF10-50 - Face Fix Handle (Optional)
Diagram 6
SF1-50 SF2L-50 SF1-50 SF2L-50 SF1-50 SF1-50 SF4-50 SF1-50 SF4-50 SF4-50 SF1-50
SF1-50 SF8-50 SF1-50 SF1-50 SF4-50 SF2R-50 SF1-50 SF1-50 SF4-50 SF8-50 SF1-50
SF1-50 SF4-50 SF1-50 SF1-50 SF4-50 SF2L-50 SF1-50 SF1-50 SF4-50 SF4-50 SF1-50
SF1-50 SF4-50 SF2L-50 SF1-50 SF4-50 SF4-50 SF1-50 SF4-50 SF4-50 SF2L-50
SF1-50 SF2R-50 SF1-50 SF2R-50 SF1-50 SF1-50 SF4-50 SF1-50 SF4-50 SF4-50 SF1-50
SF1-50 SF8-50 SF1-50 SF1-50 SF4-50 SF2L-50 SF1-50 SF1-50 SF4-50 SF8-50 SF1-50
SF1-50 SF4-50 SF1-50 SF1-50 SF4-50 SF2R-50 SF1-50 SF1-50 SF4-50 SF4-50 SF1-50
SF1-50 SF4-50 SF2R-50 SF1-50 SF4-50 SF4-50 SF1-50 SF4-50 SF4-50 SF2R-50
Diagram 8
10mm LESS THAN
DOOR THICKNESS
Diagram 7 Diagram 9
Diagram 10
4
For example: For a 4 door leaf system with a finished opening width of 2345mm the door leaf width would be 2345mm minus (5x3mm)
divided by 4 (number of door leaves) = 582.5mm.
Diagram 11
Door seals
11 Prepare the door leaves to accept the AQ63B seal. Diagram 12
SF2L-50 End
SF8-50 Meeting
Hanger Door SF2L-50 End SF2R-50 End
Door Set
Set (Left) Hanger Door Hanger Door
Set (Left) Set (Right)
Meeting doors
Use the SF8-50 set for 2+2 rebated timber door
configurations. For all other configurations use
SF2L-50 (left hand) or SF2R-50 (right hand) end
hanger sets. For kit handing refer to diagram 6.
SF2L-50 End
Hanger Door
Set (Left)
Diagram 13
5
Door hardware positioning
SF9
Diagram 14
2 WHEEL ASSEMBLY
Ø 3mm PILOT
HOLES
FIXING SCREW (6 OFF)
WASHER
HANGER BOLT
3. Cut the channel to the required length and fit in the sill.
Drill drainage holes (see diagram 1).
PIVOT SECURING BLOCK HEX
BOLTS
4. Remove all the wheel assemblies and pivot block from
the hanger and pivot bolts, and disassemble top pivot
block assembly. PIVOT CAM
11. Lift the next pair of leaves into position and support
their weight by screwing the hanger strap bolt into the
hanger wheel assembly and fixing the second and third JAMB CHANNEL
leaves together.
11
BOTTOM ANCHOR
Diagram 20 Diagram 21
8
ADJUSTMENT
INSIDE
SF4-50 ILLUSTRATED.
SAME METHOD OF
ADJUSTMENT APPLIED
TO SF1-50, SF2L-50,
Lateral Adjustment SF2R-50 AND SF8-50.
Diagram 22
1. With the unit still in the closed position, slide the set of
leaves towards the jamb to obtain the desired gap
between the jamb and the pivot door. A gap of 3mm is INSIDE
recommended using the adjustment cam. Once in
CLAMP SCREW
position tighten the clamp screws. (see diagram 24).
CLAMP SCREW
LOCKING PIVOT ADJUSTMENT CAM
2. Fold the leaves and adjust the bottom side plate using GRUB SCREW
ON INSIDE OF
the allen key provided so that the gap between the door DOOR
and the jamb is the same over the full length of the door.